Loading...
HomeMy WebLinkAboutMS 16-01; PACIFIC WIND; GEOTECHNICAL REPORT UPDATE, PROPOSED PACIFIC WIND MULTI-FAMILY RESIDENTIAL DEVELOPMENT CARLSBAD, CALIFORNIA; 2021-06-17June 17, 2021 Harding Street Neighbors, LP Project No. 33090.15 14211 Yorba Street, Suite 200 Tustin, California 92780 Attention: Mr. Todd Cottle Subject: Geotechnical Report Update, Proposed Pacific Wind Multi-Family Residential Development, Carlsbad, California. At your request we are providing this letter to update our previous geotechnical investigation (LOR, 2014) with respect to the currently proposed development as shown on the plans provided (Bassenian Lagoni, 2018) and current building code requirements (2019 CBC). On June 15, 2021, our project engineer went to the site to review the existing site conditions. The site remains in essentially the same condition as previously reported (LOR, 2014). The currently proposed development is similar to that previously reported (LOR, 2014). However, a slightly smaller project area is currently proposed. Four parcels within the northern portion of the original project are no longer included within the project. It is the opinion of this firm that our previous geotechnical investigation conducted for the property in addition to the information provided below, is considered appropriate for the design and construction of the currently proposed project. Design requirements for structures can be found within Chapter 16 of the 2019 California Building Code (CBC) based on building type, use and/or occupancy. The classification of use and occupancy of all proposed structures at the site, and thus the design requirements, shall be the responsibility of the structural engineer and the building official. For structures at the site to be designed in accordance with the provisions of Chapter 16, the subject site specific criteria is provided below: 6121 Quail Valley Court • Riverside, CA 92507 • (951) 653-1760 • (951) 653-1741 (Fax)• www.lorgeo.com Harding Street Neighbors, LP June 17, 2021 Project No. 33090.15 Chapter 20 of the ASCE 7-16 defines six possible site classes for earth materials that underlie any given site. Bedrock is assigned one of three of these six site classes and these are: A, B, or C. Soil is assigned as C, D, E, or F. Per ASCE 7-16, Site Class A and Site Class B shall be measured on-site or estimated by a geotechnical engineer, engineering geologist or seismologist for competent rock with moderate fracturing and weathering. Site Class A and Site Class B shall not be used if more than 10 feet of soil is between the rock surface and bottom of the spread footing or mat foundation. Site Class C can be used for very dense soil and soft rock with N values greater than 50 blows per foot. Site Class D can be used for stiff soil with N values ranging from 15 to 50 blows per foot. Site Class E is for soft clay soils with N values less than 15 blows per foot. Our previous investigation, mapping by others, and our experience in the site region indicates that the materials beneath the site are considered Site Class D stiff soils. CBC Earthquake Design Summary As determined in the previous section, earthquake design criteria have been formulated for the site. However, these values should be reviewed and the final design should be performed by a qualified structural engineer familiar with the region. Our design values are attached. We trust this information is as requested. Should you have any questions, please do not hesitate to contact this office. We look forward to providing additional geotechnical services for you on this very important project. Respectfully submitted, LOR Geotechnical Group, Inc. P. Leuer, GE 2030 ent AAT:JPL/ss Attachment: Seismic Design Spectra Distribution: Addressee (2) and via email todd@c-cdev.com 2 LOR GEOTECHNICAL GROUP, INC. REFERENCES American Society of Civil Engineers, 2016, Minimum Design Load for Buildings and Other Structures, ASCE 7-16. Bassenian Lagoni, 2018, Information Site Plan, Pacific Wind Apartments, Carlsbad, California, dated July 27, 2018. California Building Standards Commission and International Conference of Building Officials, 2019, California Building Code, 2019 Edition. LOR Geotechnical Group, Inc., 2014, Preliminary Geotechnical Investigation, Proposed Multi-Family Residential Project, Carlsbad Apartments, APN’s 204-292-01, -02, -10 through -14, -16 through -22, 204-291-14, -16, -17 and -19 through -27, Carlsbad, California, Project No. 33090.1, dated July 31, 2014. 3 LOR GEOTECHNICAL GROUP, INC. Project:Pacific Wind Apartments Project Number:33090.14 Client:Harding Street Neighbors, LP Site Lat/Long:33.1535 / -117.3384 Controlling Seismic Source: REFERENCE NOTATION VALUE REFERENCE NOTATION VALUE Site Class C, D, D default, or E Fv (Table 11.4-2)[Used for General Spectrum]Fv 1.9 Site Class D - Table 11.4-1 Fa 1.1 Design Maps Ss 1.069 Site Class D - 21.3(ii)Fv 2.5 Design Maps S1 0.387 0.2*(SD1/SDS)T0 0.129 Equation 11.4-1 - FA*SS SMS 1.1464* SD1/SDS TS 0.646 Equation 11.4-3 - 2/3*SMS SDS 0.764* Fundamental Period (12.8.2)T Period Design Maps PGA 0.471 Seismic Design Maps or Fig 22-14 TL 8 Table 11.8-1 FPGA 1.1 Equation 11.4-4 - 2/3*SM1 SD1 0.4936*Equation 11.8-1 - FPGA*PGA PGAM 0.532* Equation 11.4-2 - FV*S1 SM1 0.7403*Section 21.5.3 80% of PGAM 0.425 Design Maps CRS 0.894 Design Maps CR1 0.905 Cr - At Perods <=0.2, Cr=CRS CRS 0.894 Cr - At Periods between 0.2 and 1.0 Period Cr use trendline formula to complete 0.200 0.894 Cr - At Periods >=1.0, Cr=CR1 CR1 0.905 0.300 0.895 0.400 0.897 0.500 0.898 0.600 0.900 0.680 0.901 1.000 0.905 * Code based design value. See accompanying data for Site Specific Design values.Mapped values from RISK COEFFICIENT D measured https://seismicmaps.org/ Newport Inglewood-Rose Canyon LOR GEOTECHNICAL GROUP, INC. Project No:33090.14 0.010 0.547 0.511 1.19 0.608 0.100 0.948 0.896 1.19 1.066 0.200 1.281 1.216 1.20 1.459 0.300 1.412 1.314 1.22 1.603 0.500 1.312 1.211 1.23 1.490 0.750 1.043 0.956 1.24 1.185 1.000 0.843 0.771 1.24 0.956 1 Data Sources: 2.000 0.440 0.399 1.24 0.495 3.000 0.281 0.255 1.25 0.319 4.000 0.197 0.178 1.25 0.223 5.000 0.147 0.133 1.26 0.168 2 Shahi-Baker RotD100/RotD50 Factors (2014) 0.547 NO PROBABILISTIC SPECTRA1 2% in 50 year Exceedence Probabilistic PGA: Is Probabilistic Sa(max)<1.2Fa? Period UGHM RTHM Max Directional Scale Factor2 Probabilistic MCE https://earthquake.usgs.gov/hazards/interactive/ https://earthquake.usgs.gov/designmaps/rtgm/ 0.00 0.50 1.00 1.50 2.00 0.000 1.000 2.000 3.000 4.000 5.000Acceleration (g)Period (seconds) PROBABILISTIC MCER SPECTRAL RESPONSE ACCELERATIONS UGHM RTHM Probabilistic MCER LOR GEOTECHNICAL GROUP, INC. Controlling Source: Newport Inglewood-Rose Canyon NO Project No:33090.14 0.010 0.849 1.19 1.010 1.010 0.020 0.855 1.19 1.017 1.017 0.030 0.868 1.19 1.033 1.033 0.050 0.917 1.19 1.091 1.091 0.075 1.086 1.19 1.293 1.293 NO 0.100 1.282 1.19 1.525 1.525 N/A 0.150 1.558 1.20 1.870 1.870 Deterministic PGA:0.849 0.200 1.745 1.20 2.094 2.094 YES 0.250 1.895 1.21 2.293 2.293 0.300 1.978 1.22 2.414 2.414 0.400 2.013 1.23 2.476 2.476 0.500 1.951 1.23 2.400 2.400 0.750 1.605 1.24 1.990 1.990 1.000 1.349 1.24 1.673 1.673 1.500 0.944 1.24 1.171 1.171 2.000 0.702 1.24 0.870 0.870 3.000 0.458 1.25 0.573 0.573 4.000 0.303 1.25 0.378 0.378 5.000 0.215 1.26 0.271 0.271 DETERMINISTIC SPECTRUM Largest Amplitudes of Ground Motions Considering All Sources Calculated using Weighted Mean of Attenuation Equations1 Is Probabilistic Sa(max)<1.2Fa? Section 21.2.2 Scaling Factor Applied Is Determinstic Sa(max)<1.5*Fa? Section 21.2.2 Scaling Factor: Is Deterministic PGA >=FPGA*0.5? 2 Shahi-Baker RotD100/RotD50 Factors (2014) 1 NGAWest 2 GMPE worksheet and Uniform California Earthquake Rupture Forecast, Version 3 (UCERF3) - Time Dependent Model Period Deterministic PSa Median + 1.σ for 5% Damping Max Directional Scale Factor2 Deterministic MCE 0.00 0.50 1.00 1.50 2.00 2.50 3.00 0.000 1.000 2.000 3.000 4.000 5.000Acceleration (g)Period (seconds) DETERMINISTIC MCER SPECTRAL RESPONSE ACCELERATIONS Deterministic MCER LOR GEOTECHNICAL GROUP, INC. 0.010 0.608 1.010 0.608 0.405 0.005 0.323 0.259 0.100 1.066 1.525 1.066 0.711 0.010 0.341 0.273 0.200 1.459 2.094 1.459 0.973 0.020 0.377 0.301 0.300 1.603 2.414 1.603 1.069 0.030 0.412 0.330 0.500 1.490 2.400 1.490 0.993 0.050 0.483 0.387 0.750 1.185 1.990 1.185 0.790 0.060 0.519 0.415 1.000 0.956 1.673 0.956 0.637 0.075 0.572 0.458 2.000 0.495 0.870 0.495 0.330 0.090 0.625 0.500 3.000 0.319 0.573 0.319 0.213 0.100 0.661 0.529 4.000 0.223 0.378 0.223 0.148 0.110 0.696 0.557 5.000 0.168 0.271 0.168 0.112 0.120 0.732 0.585 0.136 0.764 0.611 0.150 0.764 0.611 0.160 0.764 0.611 0.170 0.764 0.611 0.180 0.764 0.611 0.200 0.764 0.611 Calculated Design 0.250 0.764 0.611 Value Value 0.300 0.764 0.611 SDS:0.962 0.962 0.400 0.764 0.611 SD1:0.660 0.660 0.500 0.764 0.611 SMS:1.443 1.443 0.600 0.764 0.611 SM1:0.990 0.990 0.640 0.764 0.611 Site Specific PGAm:0.547 0.547 0.750 0.658 0.526 Site Class:0.850 0.581 0.465 0.900 0.548 0.439 Seismic Design Category - Short*D 0.950 0.520 0.416 Seismic Design Category - 1s*D 1.000 0.494 0.395 * Risk Categories I, II, or III 1.500 0.329 0.263 2.000 0.247 0.197 3.000 0.165 0.132 4.000 0.123 0.099 5.000 0.099 0.079 Project No:33090.14 SITE SPECIFIC SPECTRA Period Probabilistic MCE Deterministic MCE Site-Specific MCE Period ASCE 7-16: Section 21.4 Design Response Spectrum (Sa) ASCE 7 SECTION 11.4.6 General Spectrum 80% General Response Spectrum D measured Site Specific LOR GEOTECHNICAL GROUP, INC. 33090.14Project No: 0.00 0.50 1.00 1.50 2.00 2.50 3.00 0.000 1.000 2.000 3.000 4.000 5.000Acceleration (g)Period (seconds) SPECTRAL RESPONSE ACCELERATIONS Probabilistic MCE Deterministic MCE Site-Specific MCE Design Response Spectrum ASCE 7 Section 11.4.6 General Spectrum 80% General Response Spectrum LOR GEOTECHNICAL GROUP, INC.