Loading...
HomeMy WebLinkAbout2470 FARADAY AVE; ; FPC2021-0215; PermitPERMIT REPORT Fire Permit Print Date: 04/04/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 2470 FARADAY AVE, CARLSBAD, CA 92010-7224 FIRE-Construction Commercial Work Class: 2090412600 Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Fire Alarm (city of Carlsbad Permit No: FPC2021-0215 Status: Closed -Finaled Applied: 11/12/2021 Issued: 11/23/2021 Finaled Close Out: 04/04/2022 Inspector: Final Inspection: Description: BECKMAN COULTER -HAZARDOUS WASTE STORAGE BLDG 5 -ADD 2 MANUAL PULL STATIONS & 3 SMOKE DETECTORS. CONN TO EXISTING SYSTEM (ADDRESSABLE DEVICES) Applicant: STANLEY SECURITY SCOTT HAIN ES 13034 CREE DR POWAY, CA 92064-3815-SAN DIEGO (858) 276-9742 FEE FIRE Tl Fire Alarm System Total Fees: $682.00 Fire Department Total Payments To Date: $682.00 FPContractor: STANLEY SECURITY 9240 TRADE PL, # STE 300 SAN DIEGO, CA 92126-6314-SAN DIEGO {858) 752-1775 Balance Due: AMOUNT $682.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov BG-12LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Ute's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4 • (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13)); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 voe. • Maximum SLC loop voltage: 28.0 voe. • Maximum SLC standby current: 375 µA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4• (10.16 cm) square electrical outlet box, or will surface mount to the model SB-1 O or SB-1/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG 12TR) may be used. The BG 12TR is DF-52013:D • E-100 @) Ftre·uTe·ALarms by Honeywell Addressable Devices 1 ~ 3 Q. ...J u.. usually needed for semi-flush mounting with 4• (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 -159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 -50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word Fl RE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-1 O or SB-1/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 • ( 1 O .16 cm) square electrical box, and shall be installed DF-52013:D • 4/13/2012-Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-UO: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UUULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA: 67-02-E. • CSFM: 7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Firelite® Alarms® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 19=i;iilii=i·i ENCIIIEIINC I MANIFACDRING QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-34 73, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 -DF-52013:D • 4/13/2012 Made in the U.S. A. DF-61010:C 5D365 Series Addressable Photoelectric Smoke Detectors @) Rre·uTe·ALarms by Honeywell The Fire•Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelligent plug-in smoke detectors are designed for both perfor- mance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more strin- gent code standards. Exclusively for use with Fire•Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLCLOOP: • Two-wire SLC loop connection • Unit uses base for wiring • Compatible with LiteSpeed™ and CLIP protocol systems • Stable communication technique with noise immunity ADDRESSING: • Addressable by device • Rotary, decimal addressing (Refer to the Fire•Lite panel manuals for device capacity.) ARCHITECTURE: • Sleek, low-profile, stylish design • Unique single-source design to respond quickly and dependably to a broad range of fires • Integral communications and built-in device-type identification • Built-in tamper resistant feature • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (LiteSpeed systems only) • Built-in functional test switch activated by external magnet • Removable cover and insect-resistant screen for simple field cleaning • Expanded color options OPERATION: • Designed to meet UL 268 7th Edition • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level • LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. • Low standby current MECHANICALS: • Sealed against back pressure • SEMS screws for wiring of the separate base • Designed for direct-surface or electrical-box mounting Addressable Devices • Plugs into separate base for ease of installation and maintenance • Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: • Optional relay, isolator, and sounder bases Installation SD365 Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Class "B" wiring only. When using relay or sounder bases, consult the /300(A) installation sheet 156-3626 for device limitations between isolator modules and isola- tor bases. Construction These detectors are constructed of fire-resistant plastic. The S0365 Series plug-in intelligent smoke detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each SD365 Series detector uses one of the panel's addresses (total limit is panel dependent) on the Fire•Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an Fire•Lite addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. DF-61010:C • 5/28/2020-Page 1 of 3 Product Line Information NOTE: "-/Vn suffix indicates CLIP and LiteSpeed device. NOTE: "An suffix indicates Canadian version. SD365: White, low-profile intelligent photoelectric sensor, LiteSpeed only SD365A: Same as SD365 but with ULC listing SD365-IV: Ivory, low-profile intelligent photoelectric sensor SD365A-IV: Same as SD365-IV but with ULC listing SD365T: White, same as SO365 but includes a built-in 135°F (57°C) fixed-temperature thermal device, LiteSpeed only SD365TA: Same as SD365T but with ULC listing SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F (57°C) fixed-temperature thermal device SD365TA-IV: Same as SD365T-IV but with ULC listing SD365R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, LiteSpeed only SD365RA: Same as SD365R but with ULC listing, for use with DNRA SD365R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW SD365RA-IV: Same as SD365R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see OF-60059. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as 8300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of 8300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of 8501-WH ITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224BI-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224BIA-WH: White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) Page 2 of 3-DF-61010:C • 5/28/2020 B200SA-WH: Same as 8200S-WH, ULC listing B200SA-IV: Same as 8200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as 8200SR-WH with, ULC listing B200SRA-IV: Same as 8200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for 821 0LP(A) base TR300-IV: Ivory, replacement flange for 821 0LP(A) base RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with 8501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack I ' SYSTEM SPECIFICATIONS Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (51 mm) high; base determines diameter -8300-6: 6.1" (15.6 cm) diameter -8501: 4" (10.2 cm) diameter For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SD365: 32°F to 122°F (0°C to 50°C} • SD365T Series: 32°F to 100°F(0°C to 38°C} • SD365R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C} UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% -93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C} ELECTRICAL SPECIF/CATIONS Voltage range: 15 -32 volts DC peak Standby current (max. avg.): 200µA @ 24 VDC (o ne communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") DETECTOR SPACING AND APPLICATIONS Fire•Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document SPAG91, is available at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the SD365 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listing: S1059 • FM Approved • CSFM: 7272-0075:0502 LiteSpeed™ is a trademark, and Fire•Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 i+l=l;iilil=i·) ENGlrlEIING I MMIFACTIRING QUALITY SYSTEMS Page 3 of 3-DF-61010:C • 5/28/2020 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX:(877) 699-4105. Country of Origin: Mexico www.firelite.com