HomeMy WebLinkAbout6155 EL CAMINO REAL; ; FPC2021-0140; PermitPERMIT REPORT Fire Permit Print Date: 04/20/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 6155 EL CAMINO REAL, CARLSBAD, CA 92009-1602 FIRE-Construction Commercial Work Class: 2131000100 Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Fire Alarm {city of Carlsbad Permit No: FPC2021-0140 Status: Closed -Finaled Applied: 07/27/2021 Issued: 08/10/2021 Finaled Close Out: 04/20/2022 Inspector: Final Inspection: Description: VIASAT BLDG 1 -REVISED PLANS FOR NEW FIRE ALARM SYSTEM (ADDRESSABLE, 166 DEVICES) FEE FIRE New Alarm System FIRE Plan Review (per hr -Regular Office Hours) FIRE Reinspection (per Inspection) Total Fees: $1,700.50 Total Payments To Date: Fire Department $1,700.50 FPContractor: JJJ ENTERPRISES MARIO AGUERO 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 x209 Balance Due: AMOUNT $1,265.00 $223.50 $212.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov September 28, 2021 To: Attn: Subject: Project Address: Carlsbad Fire Department Plan Check Department ViaSat WI 6155 El Camino Real. Permit# FPC2021-0140 P.O. BOX 463021 -ESCONDIDO, CALIFORNIA 92046-3021 (760)747-3 050 -FAX (760)7.47-7561 Fire Alarm drawings for the above project have been revised per updated floor plans. The following is a list of changes made to the plans. 1. F A-1 The Model for the Notifier Power Supply has been change to PSE-6. New data sheet for the PSE-6 has been provided. 2. FA-1 Device Legend has been updated to include new added strobes and horn strobes. 3. FA-5 new strobes and horn strobes have been added per updated floor plan. 4. All changes have been clouded with delta #1. Voltage drops calculations have been revised according! y. Feel free to give me a call with any questions that you may have. 760 747-3050 Ext. 209 or e-mail mario@jjjent.com Sincerely, Mario Aguero FIRE ALARM j ,, SECURITY Via Sat Building 1 6155 El Camino Real Carlsbad, CA 92011 LOW VOLTAGE SYSTEMS FIRE ALARM SYSTEM MATERIAL DATA SHEETS • FIRE ALARM SYSTEM BILL OF MATERIALS NOTIFIER NFS-320 FIRE ALARM CONTROL PANEL CSFM# 7165-0028 :0243 NOTIFIER UDACT UNIVERSAL DIGITAL COMMUNICATOR CSFM# 7165-0028:0243 DMP COMMERCIAL FIRE COMMERCIAL COMMUNICATOR SLCF CSFM# 7300 -1157:0136 NOTIFIER FDU-80 ANNUNCIATOR CSFM# 7120-0028:0209 SPACE AGE ELECTRONICS INC. FAD SSU00685 FIRE ALARM DOCUMENTS RED CSFM# 7300-0553:0110 NOTIFIER PSE-6 REMOTE POWER SUPPLY CSFM# 7315-0028 :0513 NOTIFIER FSP-951 INTELLIGENT SMOKE DETECTOR CSFM# 7272-0028 :0503 NOTIFIER NBG-12LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028 :0199 NOTIFIER FST-951 INTELLIGENT HEAT DETECTOR CSFM# 7272-0028 :0502 NOTIFIER FMM-101 ADDRESSABLE MODULES CSFM# 7300-0028 :0219 NOTIFIER FRM-1 ADDRESSABLE RELAY MODULE CSFM# 7300-0028 :0219 SYSTEM SENSOR INNOVAIRFLEX DNR DUCT SMOKE DETECTOR HOUSING W/FSP- 951R DETECTOR HEAD CSFM# 3242-1653 :0209 SYSTEM SENSOR PC2WL, SCWL -CEILING MOUNTED HORN/STROBE & STROBE CSFM# 7135-1653 :0503, 7125-1653 :0504 SYSTEM SENSOR P2RL -WALL MOUNTED HORN/STROBE CSFM# 7135-1653 :0503 SYSTEM SENSOR SRK -WALL MOUNTED OUTDOOR STROBE CSFM# 7300-1653 :0187 i'Bll;IIQ Intelligent Addressable Fire Alarm System General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. As a stand-alone small-to-medium system, or as a large net- work, the ONYX Series of products meets virtually every appli- cation requirement. Designed with modularity and for ease of system planning, the NFS-320 can be configured with just a few devices for small building applications, or for a large campus or high-rise appli- cation. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific "C" or "E" at the end of the part number, "NFS-320" refers to models NFS-320, NFS-320C, and NFS-320E; similarly, "CPU-320" refers to models CPU-320, CPU-320C, and CPU-320E. Features • One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. • Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (N.O. manual stations, two- wire smoke, notification, or relay). 318 devices maximum. • Standard BO-character display. • Network option -103 nodes supported (AFP-200, AFP- 300/400, NFS-320, NFS-640, NFS2-640, AFP1010, AM2020, NFS-3030, NFS2-3030, NCA/NCA-2 Network Annunciator, NCS Network Control Station, or ONYX- Works ™ Network Control Station) using wire or fiber-optic connections. • 6.0 amp power supply with four Class A/8 built-in Notifica- tion Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, and Supervisory relays. • VeriFire® Tools offline program option. Sort Maintenance Reports by compensation value (dirty detector), peak alarm value, or address. • Autoprogramming and Walk Test reports. • Optional universal 318-point DACT. • BO-character remote annunciators (up to 32). • EIA-485 annunciators, including custom graphics. • Printer interface (80-column and 40-column printers). • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Positive Alarm Sequence (PAS) Presignal. • Silence inhibit and Auto Silence timer options. • March time / temporal / California two-stage coding / strobe sync_hron ization. • Field-programmable on panel or on PC, with VeriFire Tools program check,· compare, simulate. • Full QWERTY keypad. • Charger for up to 90 hours of standby power. • Non-alarm points for lower priority functions. • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. DN-7112 • A-14 {§)NOTIFIER® by Honeywell Intelligent Fire Alarm Control Panels NFS-320 • Automatic time control functions, with holiday exceptions. • Surface Mount Technology (SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. FLASHSCAN® INTELLIGENT FEATURES: • Poll 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol (U .S. Patent 5,539,389). • Manual sensitivity adjustment -nine levels. • Pre-alarm ONYX intelligent sensing -nine levels. • Day/Night automatic sensitivity adjustment. • Sensitivity windows: -Ion -0.5 to 2.5%/foot obscuration. -Photo -0.5 to 2.35%/foot obscuration. -Laser (VIEW®) -0.02 to 2.0%/foot obscuration. -Acclimate Plus™ -0.5 to 4.0%/foot obscuration. -HARSH™ -0.5 to 2.35%/foot obscuration. • Drift compensation (U.S. Patent 5,764,142). • Degraded mode -in the unlikely event that the CPU-320 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU-320 NAC cir- cuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. • Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). • Automatic detector sensitivity testing. • Maintenance alert (two levels). • Self-optimizing pre-alarm. DN-7112 • 01/10/07 -Page 1 of 8 VIEW (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831 ,524). • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MUL Tl-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible with NFS2-640, NFS-320. • Low-temperature warning signal at 40°F ± 5°F (4.44 °C ± 2.77°C). HARSH HOSTILE-AREA SMOKE HEAD: • Provides early warning of smoke detection in environment where traditional smoke detectors are not practical. • The detector's filters remove particulates down to 30 microns in size. • Intake fan draws air into photo chamber, while airborne par- ticles and water mist are removed. • Requires auxiliary 24 VDC from system or remote power supply. RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone (three options). • Delay timer and Discharge timers (adjustable). • Abort (four options). • Low-pressure CO2 listed. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY "{6.0 A IN ALARM): • 120 or 220/240 VAC. • Displays battery current/voltage on panel (with display). VOICE FEATURES: • Integrates with FireVoice-25/50 Series. Up to 32 Remote Displays SLC lntemgent Loop FDU-80 Sample System Options Page 2 of 8 -DN-7112 • 01/10/07 ~ DEVICES . FAPT-851 Acclimate Plus™ ----- FSL-751 FlashScan® VIEW® FSH-751 FlashScan® HARSH'" NBG-12LX FMM-1 FRM-1 FSP-851 FlashScan® photo t I etc. • XP6/10 1/0 Modules IDC Relay Contact EIA-485 2048 annunciator/control points NFS-320 ACM-BR Relay Control ACM/AEM-24AT LED Annunciator Optional 318 point UDACT EIA-232 Terminal T -IIID\ r. EIA-232 ,a;g• \ PRN Printer CRT-2 Terminal LDM-32 Custom Graphics Dual phone lines to Central Station 7112blok.wmf FlashScan, Exclusive New World-Leading Detector Protocol At the heart of the NFS-320 is a set of detection devices and device protocol -FlashScan (U.S. Patent 5,539,389). Flash- Scan is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this new protocol can also activate many output devices in a fraction of the time required by competitive proto- cols. This high speed also allows the NFS-320 to have the largest device per loop capacity in the industry -318 points -yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the very- high-speed microcomputer used by the NFS-320. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value, usually indicative of a hardware problem in the detector; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate .special control func- tions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature of the NFS-320. It is a special software routine that allows the NFS-320 to "learn" what devices are physically connected and automatically load them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel key- pad, while continuing to provide fire protection. The architecture of the NFS-320 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per-point segments, while the NFS-320 simulta- neously monitors other (already installed) points for alarm con- ditions. VeriFire Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows®-based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS-320 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Below: Autoprogram function. 6856tool.tif VeriFire Tools System Programming screen DN-7112 • 01/10/07 -Page 3 of 8 CPU-320 Board Diagram All NAC circuits are power-limited, supervised. TB9: NAC#1 .... LEDs 11, 12 TBS: NAC#2 LEDs 13, 14 TB7: NAC#3 LEDs 15, 16 o LED3 Ef,RTH FAULl LED3: Earth Fault (general board ground fault). @) TB10: DC Power (24 VDC, power-limited); Non-Resettable, Resettable. TB11: EIA-485 Connection (supervised); Terminal Mode, ACS Mode. TB12: EIA-232 Connection; Printer, PC!Terminal (CRT). SW1: Ground Fault Detection Enable/Disable. F2: 15 A Sia-Blow Fuse, P/N 12057. JS: Zone Coder Connection. TB3: Battery Connection; over-current protected, non-power-limited. J1: Network/Service Connection (NUP), power-limited, supervised. J2: USB A VeriFire Tools Connection. J3: USB B VeriFire Tools Connection. JP1: Ground Fault Jumper (SLC #1 ). TBS: NAC#4 LEDs 17, 18 TB1: AC Power Connection LED10: SLC Loop Ground Fault. .,.. (non-power-limited): U Hot, Neutral, and ~i TB1 Earth Ground. □! o e o CD 0 0 0 0 0 0 0 0 0 0 0 CD ® TBS: Relays: EA~lH Supervisory, TBS Security , ~--_ e SUP/. •·· SEC C ALARM TROUBLE TB4: Alarm Relay, Trouble Relay. Output relays; power-limited only if connected to a power-limited source. 7112bord.wmf Network Diagram ,n[~:~~~~:;\ ~---------- PRN ACS Page 4 of 8 -DN-7112 • 01/10/07 ~ JS: Auxiliary Trouble Input. JS: Security Tamper Switch. 4"'~~-t . ws SW6 SW7 ,;~,t~:.L~-!;_, LED1 (§) (§) ~ i i ~ ~~~ (;I;I;t1;I;l;l;fil~!:l:Jml:{:yJ 1~~~1~~~umnf·~ ~ 0 sw:.1., .,i, ,,3,,4, SW1, SW2, SW3,SW4: Disable-Enable switches for Backup Alarm, NACs 1 -4 respectively. NCS or ONYXWorks NFS2-640 System switches, "No Keyboard Operation": J7: KDM-R2 Connection LED1: Power On (AC or battery) LED2: Signals Silenced LED3: Point Disabled SWS Acknowledge SW6 Silence LED4: System Trouble SW7 Reset LEDS: Supervisory LEDS: Security LED7: Pre-Alarm LEDS: Fire Alarm Block Diagram NOTl•FIRE•NET Sample Node Configurations KEY· cx:x:xxx:> NFN Twisted-Pair Wire NFN Dual Fiber-Optic Link ----Other Interfaces OPTIONAL Style 7 Connection NFS-320 NCS or ONYXWorks 0 FDU-80 b1~~~=\ PRN ACS Placement of Equipment in Chassis and Cabinet The following guidelines outline the N FS-320's flexible system design. Wiring: When designing the cabinet layout, consider separa- tion of power-limited and non-power-limited wiring as dis- cussed in the NFS-320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a NCM-W (wire) or NCM-F (fiber) Network Con- trol Module. The NCM-W/-F can be installed in any option board position (see manual). Option boards can be mounted in front of the NCM modules. KDM-R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout). 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Membrane Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED back- light. Configuration Guidelines The NFS-320 system ships assembled; description and some options follow. NFS-320: The standard, factory-assembled NFS-320 system includes the following components: one CPU-320 control panel mounted on chassis (120 V operation -ships with grounding cable, battery interconnect cables, and document kit); one KAPS-24 integral power supply mounted to the CPU- 320; one primary display KDM-R2 keypad/display; and one cabinet for surface or semi-flush mounting. Purchase batteries separately. One or two option boards may be mounted inside the NFS-320 cabinet; additional option boards can be utilized in remote cabinets. NFS-320R: Same as NFS-320 above, but in red enclosure. NFS-320C: Same as NFS-320 above, but with ULC listing. See Canadian applications manual addendum 52747. NFS-320E: Same as NFS-320 above, but with 240 V operation. BMP-1: Blank module for unused module positions. TR-320: Trim ring for the NFS-320 cabinet. ~ : ~ r SLOT 1: CPU, KAPS-24, and primary display. ! r~.:-.. ,,~ r SLOT 2: CPU, KAPS-24, and primary display. Keypad/display unit attaches to chassis rails. Panel ships factory- assembled, with chassis installed with CPU, KAPS-24, and KDM-R2. (: ~ '0 ' il, Equipment Placement in NFS-320 Chassis r-SLOT 3: Mounting location, + option board. ,, ~.· ~ DN-7112 • 01/10/07 -Page 5 of 8 Option Modules FCPS-24S6/-24S8: Remote six-amp and eight-amp power supplies with battery charger. See FCPS-24S6/-24S8 data sheet, DN-6927. COMPATIBLE DEVICES, EIA-232 PORTS PRN-6: BO-column printer. See DN-6956. VS4095/S2: Printer, 40-column, 24 V. Mounted in external backbox. See DN-3260. CRT-2: Video display terminal. See DN-3756. COMPATIBLE DEVICES, EIA-485 PORTS ACM-24AT: ONYX Series ACS annunciator -up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator -up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expand- able to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit; mount on NFS-320 chas- sis or remotely. See DN-6860. FDU-80: Remote LCD display, 80 characters, with LEDs. See DN-6820. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- R32; remote custom driver modules. See LDM data sheet, DN-0551. ACM-SR: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See ACM-BR data sheet, DN-3558. RPT-485 Series: Repeater, isolator and/or fiber-optic modem; repeats EIA-485 over twisted pair or converts to fiber-optic medium. See RPT data ·sheet, DN-4737. SCS: Smoke control stations SCS-8, SCE-8, with lamp driv- ers SCS-8L, SCE-8L; eight (expandable to 16) circuits. See SGS data sheet, DN-4818. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-4867. UZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microproces- sor-controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). See UZC-256 data sheet, DN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB- 200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB- 200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. BEAMMRK: Multi-mount kit, -FSB-200(S) below. BEAMSMK: Surface-mount kit, FSB-200(S) below. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6895. FSl-851: Low-profile FlashScan ionization detector, will replace FSl-751. See DN-6934. Page 6 of 8-DN-7112 • 01/10/07 FSl-751: Low-profile FlashScan ionization detector. See DN- 6714. FSP-851: Low-profile FlashScan photoelectric detector, will replace FSP-751. See DN-6935. FSP-751: Low-profile FlashScan photoelectric detector. See DN-6714. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal, will replace FSP-751T. See DN-6935. FSP-751T; Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6714. FST-851: FlashScan thermal detector 135°F (57°C), will replace FST-751. See DN-6936. FST-751: FlashScan thermal detector 135°F (57°C). See DN- 6716. FST-851 R: FlashScan thermal detector 135°F (57°C) with rate-of-rise, will replace FST-751 R. See DN-6936. FST-751 R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6716. FST-851 H: FlashScan 190°F (88°C) high-temperature ther- mal detector. See DN-6936. FSD-751 P: FlashScan photo duct detector with housing. See DN-6821. FSD-751 PL: Low-flow FlashScan photo duct detector with housing, will replace FSD-751P. See DN-6955. FSD-751 RP: FlashScan photo duct detector with relay and housing. See DN-6821. FSD-751 RPL: Low-flow FlashScan photo duct detector with relay and housing, will replace FSD-751 RP. See DN-6955. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor detector, will replace FAPT-751. See DN-6937. FAPT-751: Acclimate Plus low-profile multisensor detector. See DN-6833. FSH-751: FlashScan HARSH Hostile Area Smoke Head. See DN-6875. FSL-751: FlashScan VIEW laser photo detector, will replace LPX-751. See DN-6886. LPX-751: Low-profile VIEW laser photo detector. See DN- 5306. B224RB: Low-profile relay base. B224BI: Isolator base for low-profile detectors. B710LP: Low-profile base. Standard U.S. style. B501: European-style, 4" (10.16 cm) base. B501 BH: Sounder base, includes 8501 base above. FMM-1: FlashScan monitor module. See DN-6720. FDM-1: FlashScan dual monitor module. See DN-6720. FZM-1: FlashScan two-wire detector monitor module. See DN-6720. FMM-101: FlashScan miniature monitor module. See DN- 6720. FCM-1: FlashScan NAC control module. See DN-6724. FRM-1: FlashScan relay module. See DN-6724. NBG-12LX: Manual fire alarm station, addressable. See DN- 6726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See DN-6926. XP10-M: Flash Scan ten-input monitor module. See DN-6923. OTHER OPTIONS DPl-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals; mount on NFS-320 chassis. See DN-6870. NCM-W: Network Communications Module, Wire. Order one NCM per network node (CPU-640 or NCA). See DN-6861. NCM-F: Network Communications Module, Fiber. Order one NCM per network.node (CPU-640 or NCA). See DN-6861. NCSS-W-ONYX: Network Control Station, Wire. UL-Listed graphics PC with mouse, 17" color flat-screen LCD monitor. Order as necessary for network systems. Each NCS con- sumes one of 103 network addresses. See DN-6868, ONYX DN-6869. NCSS-F-ONYX: Network Control Station, Fiber. UL-Listed graphics PC with mouse, 17" color flat-screen LCD monitor. Order as necessary for network systems. Each NCS con- sumes one of 103 network addresses. See ONYX DN-6869. ONYXWORKS-NW: Workstation with NFN wire PC card. ONYXWorks workstation GUI software and hardware package fo_r NOTl:FIRE•NET. Includes NFN Gateway (NFNGW-PC-W) wrre version. ONYXWORKS-NF: Workstation with NFN fiber PC card- ONYXWorks workstation GUI software and hardware package for NOTl•FIRE•NET. Includes NFN Gateway (NFNGW-PC-F) fiber version. ONYXWORKS-EW: Workstation with Echelon wire PC card ONYXWorks workstation GUI software and hardware package for Building Systems Integration, WSSUP Workstation Super- visor. Includes Echelon® Gateway (ECH-GW-PC-W) wire ver- sion. NFN-GW-EM: NFN Gateway, embedded. VeriFire-TCD: VeriFire Tools CD-ROM. Contains program- ming software for the ONYX Series. Includes local panel con- nection cable. Programming PC requires a serial port connection. See DN-6871. BAT Series: Batteries. NFS-320 utilizes two 12 volt, 18 to 200 AH batteries. This series of products replaces the previ- ous PS Series. See DN-6933. NFS-LBB: Battery Box (required for batteries over 25 AH). NFS-LBBR: Same as above, but red. DN-7112 • 01/10/07 -Page 7 of 8 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits ....................................... 1 • Intelligent detectors ....................................................... 159 • Addressable monitor/control modules ............................ 159 • Programmable internal hardware and output circuits ........ 4 • Programmable software zones ......................................... 99 • Special programming zones ............................................. 14 • LCD annunciators per CPU-320/-320E ............................ 32. • ACS annunciators per CPU-320/-320E ...................... 32 addresses x 64 points Specifications • Primary input power, CPU-320 board: 120 VAC, 50/60 Hz, 3.0 A. CPU-320E board: 220/240 VAC, 50/60 Hz, 1.5 A. • Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. Standard notification circuits (4 ): 1.5 A each. Four-wire detector power: 1.25 A. Non-resettable regulated power outputs: 1.25 A each. Battery charger range: 18 AH -200 AH. Use separate cabi- net for batteries over 25 AH . Optional high-capacity (25 -120 AH) battery charger: CHG- 120 (see CHG-120 data sheet, DN-6040). Float rate: 27.6 V. Cabinet Specifications NFS-320 cabinet dimensions: BACKBOX, OUTSIDE: 18.240" (46.33 cm) height, 5.77" (14.656 cm) deep. WITH DOOR: 18.870" (47.93 cm) wide x 18.469" (46.911 cm) high x 5.817" (14.775 cm) deep. BACKBOX, INSIDE: 18.120" (46.025 cm) inner width, 5.175" (13.145 cm) inner depth. Temperature and Humidity Ranges This system meets NFPA requirements for operation at O - 49°C/32 -120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 -27°C/60 -80°F. Agency Listings and Approvals The listings and approvals below apply to the basic NFS-320 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: file S635. • ULC Listed: file S635. Standards The NFS-320 complies with the following UL Standards and NFPA 72 Fire Alarm Systems requirements: -UL 864 (Fire). -UL 1076 (Burglary). -LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). -AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). -REMOTE STATION (Automatic, Manual and Waterflow) (requires 4XTMF). -PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. -EMERGENCY VOICE/ALARM. Acclimate Plus TM, HARSH TM, NOTl•FIRE•NETTM, and ONYXWorks TM are trademarks; and FlashScan®, NION®, NOTIFIER®, ONYX®, UnlNet®, Verifire®, and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. Echelon® is a registered trademark of Echelon Corporation. IBM® is a registered trademark of IBM Corporation. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. 19=i;iiiil=i•i ENCIIIEIINC I MANIFSTIRING QUALITY SYSTEMS Page 8 of 8 -DN-7112 • 0V10/07 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161 , FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS. LISTING PROGRAM LISTING SERVICE 7165'.'.'0028:0243< · 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 4 Models NFS2-640, NFS-320/C (R}, and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU}, central station (PPU}, manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System*. Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-610, AMPS-24; Addressable power supply/charger ADP-4B, -A4, -1, -2, DP-DISP2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch APS2-6R; Power supply 88-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1 ; Blank Module BP-4, BP2-4; Battery Dress Plates CAB-3/-4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1 B; Blank Panel DPA-1A4/1/2, DP-Dl$P2; Dress Panel DPl-232; Panel Interface DR-A4, DR-A48, DR-A4BR, DR-A4R; Door Assembly DR-M4, DR-M48, DR-M48R, DR-M4R; Door Assembly DR-B3F; Door Assembly DR-B4, DR-B4B, DR-84BR, DR-B4R; Door Assembly DR-C4, DR-C48, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30; 2022 Listing No. 7165-0028:0243 EQ Series; Cabinets EQBB-84, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-84, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-24S6, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 :Multiple Module with two Relay Outputs FDU-80/-80G; Remote Annunciator FIRSTVISION-LCD/ENC; Interactive Firefighters' display/enclosure FRM-1 ; Relay Module FTM-1 ; Control Module FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-W/-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-12LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCSS-W-ONYX, NCSS-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/S0ZS/ZST; Voice Evacuation Control Panels NFV-25/S0DA, NFV-25/S0DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-HNMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTI •FIRE•NET, Wire/Fiber/ with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-B4, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly Page 2 of 4 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but · does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-2B; Dress Panel XP5-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-1; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMIC-1, CMIC-RP; Microphone Assembly DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers DAA-5070F/DAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA .. 7.525SF; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAX-3525/-3~70/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier OS-DB; Digital Series Distribution Board DS-FM, DS:-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command Listing No. 7165-0028:0243 Page 3 of 4 DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1 SA; Remote Microphone *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 INSTALLATION: MARKING: APPROVAL: NOTE: Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPIQ: Transponder Quad Intelligent Audio In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical ratings, and UL Label Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/ReseURestart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 :UDACT-2 Universal Digital Alarm Communicator Transmitter General The Universal Digital Alarm CommunicatorTransmitter (UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTl•FIRE•NET™. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features • Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. • Maximum of 14 point trouble messages transmftted per hour. • Dual phone lines with line voltage detect. • Compact in size: 6.75" x 4.25" .(17.145 x 10.795 cm). • USB port for upload/download programming. • Manual Test Report function .. • Manual Transmission Clear function. • Mounts in a separate enclosure (ABS-8RB or UBS-1 B/R). • Communicates vital system status including: -Independent zone fire alarm. -Independent zone non-fire alarm. -Independent zone tr9uble. -Independent zone supervisory. -AC (mains) Power Loss (programmable). -Low Battery and Earth Fault. -System Off-Normal. -12 or 24 hour test signal. -Abnormal Test Signal per new UL requirements. -EIA-485 Communication Bus Failure. • Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. • Individual LEDs for: Power, EIA-485 Loss, Manual Test, Ki$- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. DN-60686:A 1 (Gj)NOTIFIER® by Honeywell Annunciator Control System UDACT-2 • Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. • Real-time clock. • Extensive transient protection. • EIA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. DN·60686:A 1 • 4/2/12 -Page 1 of 2 Communication Formats • Ademco Contact ID • 4+2 Standard • SIA NOTE: Ademco Contact ID must be used tor independent zone reporting. Type Mode Feature Ademco Contact ID format -only Use Type Mode to identify reports to Central Station as: • Fire Alarm • Burglary • Supervisory • 24 hour Non-Burglary • Pull Station • High Temperature • Heat Detector • Low Temperature • Waterflow • Low Water Pressure • Duct Detector • Low Water Level • Flame Sensor • Pump Failure • Smoke Zone Electrical Specifications Standby current: fO mA. Current while communicating: 75 mA. Maximum current while communicating and with open collector output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listed: S635 • FM Approved • CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (NFS2-3030) • FDNY: COA#6085, COA#6098 Ordering Information UDACT-2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mounting hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94" H x 4.63" W x 2.50" D (cm: 25.248 H x 11.760 W x 6.350 D). UBS-1 B: Metal enclosure with solid door, Black. UBS-1 BR: Metal enclosure with solid door, Red. R-1 OE: SPOT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 1 0A @ 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. UL Listed Receivers The chart below shows UL listed receivers compatible with the UDACT-2. A check in the protocol column indicates the receiver supports that protocol. 4+2 Ademco Standard Contact Receiver 180012300 ID SIA Ademco 685 ( 1) v" v" Ademco MX8000 (2) v" v" v" Silent Knight 9500 (3) v" v" v" Silent Knight 9800 (4) v" v" v" FBI CP220FB (5) v" v" v" Osborne Hoffman 2000E (6) v" v" Radionics 6600 (7) v" v" SurGard MLR2 (8) v" v" SurGard System Ill (9) v" v" SurGard MLR-2000 (10) v" (1) With 685-8 Line Card with Rev 4.4d software (2) With 124060V206B and 124063 Line Card Rev B (3) With version V2.4 Receiver & 126047 Line Card Rev G (4) With 124077V2.00 Receiver &126047 Line Card Rev M (5) With software V3.9 (6) With V. 7301 Receiver S/W (7) With 01.01 .03 Receiver S/W & Line Card 01.01 .03 (8) With software V1 .86 (9) With sotware V1 .72 (10) With DSP4016 and V1 .6 Line Card NOTl•FIRE•NET™ is a trademark and Notifier® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. I➔ =1-0 • =ii =I •1 ENGINEERING & MANIFACTURING QUALITY SYSTEMS We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 -DN-60686:A 1 • 4/2/12 Made in the U.S. A. LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0028:0243 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 4 Models NFS2-640, NFS-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System*. Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-610, AMPS-24; Addressable power supply/charger ADP-4B, -A4, -1, -2, DP-DISP2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP-4, BP2-4; Battery Dress Plates CAB-3/-4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1 B; Blank Panel DPA-1A4/1/2, DP-DISP2; Dress Panel DPl-232; Panel Interface DR-A4, DR-A4B, DR-A4BR, DR-A4R; Door Assembly DR-M4, DR-M4B, DR-M4BR, DR-M4R; Door Assembly DR-B3F; Door Assembly DR-B4, DR-B4B, DR-B4BR, DR-B4R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E Fire Engineering Division Listing Expires June 30, 2022 Listing No. 7165-0028:0243 EQ Series; Cabinets EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-24S6, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 :Multiple Module with two Relay Outputs FDU-80/-B0G; Remote Annunciator FIRSTVISION-LCD/ENC; Interactive Firefighters' display/enclosure FRM-1 ; Relay Module FTM-1 ; Control Module FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-W/-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-12LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR;· Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/50ZS/ZST; Voice Evacuation Control Panels NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-HNMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTl•FIRE•NET, Wire/Fiber/ with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-84, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly Page 2 of 4 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-2B; Dress Panel XP5-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-1; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMIC-1, CMIC-RP; Microphone Assembly DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers DAA-5070F/DAA-5070SF; D,igital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command Listing No. 7165-0028:0243 Page 3 of 4 DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1SA; Remote Microphone *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 INSTALLATION: MARKING: APPROVAL: NOTE: TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio Listing No. 7165-0028:0243 Page 4 of 4 In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical ratings, and UL Label Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 SYSTEM FEATURES • Fully supervised universal fire alarm communication over CDMA • Program your own account number to easily workaround locked panels • Contact ID dialer capture • Four zones or Bell Monitoring • Two outputs The CellComSL:CF Comn1ercial Fire Alarm Communicator pr~vides a fuUy supervised alarm communication path over the CDMA network and it meets the NFPA 72 standard for commercial fire applications. • External SMA antenna • Wiring for Ademco ECP Bus • Communicates with DMP SCS-1 Rand SCS-VR Receivers • Builds customer loyalty: creates new RMR • Private labeling available on the rubber logo insert • 12 or 24VDC fiRE COMMUN!CATiON The CellComSLCF offers cellular fire communication on any fire control panel via Contact ID Captures or Zone Inputs. Meets NFPA 72 Standard for Single Communication Technology. WORKS WrfH MOST Pt"\NELS If the existing panel supports Contact ID. then it's a candidate for upgrading with the CellComSLCF. flELD PANEL UPDATES The Model 400 USS Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. FULLY SUPEFMSED Provides a fully supervised alarm communication path for burglary control panels over the CDMA network providing higher speeds. MULT~PLE CCJNNECTION OPTiONS CellComSL communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer. or connect the four input zones from outputs on the panel: or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the Central Station. FOUB ZONES Each of the CellComSL models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. CEFrm=K;ATIONS EASY UPGBADE FOR OLALEFt- Older. dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels. enabling them to increase the ROI on their system investment and build satisfaction with the purchase decision. BWUJ CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. When the time does come to replace the panel. they are more likely to rely on you. SPECIFiCft~TiONS Dimensions: 5.5" W x 3. 75" H x 1" D Red California State Fire Marshal (CSFM) Color: Open-Collector Outputs: Zones: Primary Power: Current Draw at 12 VDC: Standby Alarm Current Draw at 24 VDC: Standby Alarm 2 4 Nominal 12 VDC or 24 VDC 55mA 102 mA (Cellular Communication} 28mA 49 mA (Cellular Communication} ANSI/UL 864 Fire Protective Signaling Systems Cellular FCC Part 15: MIVCNN0301 M -0 -..;r s i = iiiii ~ iiiii ::, iiiii "C iiiii £ C) iiiii C: iiiii ] = ·c: ~ = lg -·m -i5 iiiii iiiii = LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1157 :0136 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com Page 1 of 1 Models CellComSLC, CellComSLCZ, CellComSLCF, CellCom-L TE-V, CellComZ-L TE-V, CellComF-LTE-V, iComSLF, iCOMSL, iComSLZ, DualComNF-L, *CellComSF, and *CellComDF Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. 12 voe or 24 voe In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Revision 02-26-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing.~xpires< ·· June 30, 2022 ~NOTIFIER® by Honeywell PSE-6/PSE-10 Series 6/10 Amp, 24 Volt Power Supply Expanders General The PS Series is a remote power supply line from NOTIFIER and is a direct replacement for the FCPS-24S6/8 Series. The PSE-6(C)(E) is a 6 amp and the PSE-1 0(C)(E) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appli- ance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm sys- tem peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabi- net. The PSE-6E and PSE-1 OE are models rated for 240V opera- tion. Features • Up to five (6 amp model) or seven ( 10 amp model) inde- pendently-configurable, power-limited output circuits for: -Class B and/or Class A NACs -Class B and/or Class A resettable or non-resettable 24V auxil- iary power -door holder power • Converts from Class B to Class A wiring without losing any out- puts using the ZNAC-PS converter card (sold separately) • Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL-Listed NAC synchronization using System Sensor®, Whee- lock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully-isolated inpuU control circuits which can be programmed to any output • Two Form C normally-closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian mod- els only • 6 or 10 amp full load output, respectively, with 3 A maximum/cir- cuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history modes for diagnostic support • Wide range end-of-line supervision value (normal: 2K-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra soft- ware required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled vfa DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1 mm2) wire • Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit • Optional devices include addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) Standards and Codes The PSE Series comply with the following standards: • NFPA 72 National Fire Alarm Code • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode), 10th Edition • UL 1481 Power Supplies for Fire Alarm Systems • IBC 2009 (when using SEISKIT-MULTl-1) • CBC 2007 (when using SEISKIT-MULTl-1) Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635, S674 • ULC Listed: S635 (PSE-6/1 0C) • CSFM Approved: 7315-0028:0513 • FDNY Approved • FM Approved DN-61092:C • 3/10/2021 -Page 1 of 2 SPECIFICATIONS Primary (AC) Power: • PSE-6(C): 120 VAC, 50/60 Hz, 5.0A maximum • PSE-10(C): 120VAC, 50/60 Hz, 6.2 A maximum • PSE-6E: 240 VAC, 50/60 Hz, 2.7A maximum • PSE-1 OE: 240 VAC, 50/60 Hz, 3.5A maximum • Wire Size: #12-14 AWG with 600 V insulation Command Input Circuit: • Trigger Input Voltage: 9 to 32 VDC • Trigger Current: 2.0 mA (16 -32 V); Per Input: 1.0 mA (9 -16 V) Trouble Contact Rating: 4 A at 24 VDC Output Circuits: • 24 VDC filtered, regulated • PSE-6: TB8-TB9 -1A Regulated, 3A special applications; TB10- TB12 -0.3A Regulated, 3A special applications • PSE-10: TB8-TB11 -1.5A Regulated, 3A special applications; TB12-TB14 -0.3A Regulated, 3A special applications • 6.0 A (PSE-6) or 10.0 A (PSE-10) maximum total continuous cur- rent for all outputs Secondary Power (Battery) Charging Circuit: • Supports lead-acid batteries only • Float-charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) Physical: • Dimensions: 20.0"H x 14.5"W x 3.5"0 (cm: 50.8H x 36.83W x 8.9D) • Weight: with two ?Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds ( 17. 7 kg) ISO 9001 ~i'.l1~t~. QUlllTY SYSTEMS Ordering Information PSE-6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure PSE-6C: Same as above, ULC-listed model PSE-6R: Same as PSE-6 with red enclosure PSE-6E: 6.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure PSE-10: 10.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure PSE-10C: Same as above, ULC-listed model PSE-10R: Same as PSE-10 with red enclosure PSE-10E: 10.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure ZNAC-PS: Optional Class A output converter module FCM-1: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notifica- tion appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch FMM-1: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end- of-line resistor. Module may be configured for either a Class B or Class A IDC. FDM-1: Dual Monitor Module. Same as FMM-1 except it provides two inputs for Class B wiring only FDRM-1: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only. XP6-C: Six-circuit supervised control module XP6-R: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required, see BAT Series data sheet DN-6933). BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MUL Tl-1: Seismic kit for the PSE Series. Includes bracket and hardware for two 7 AH or two 18AH batteries. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. \OT!F1 .. Jc., d. :(1 S;~•&!.: ,~0n,10(~· <Sr~. :~_)->h,e .. ~ ·r~:.te:::.~rk, ;.;" •-io:i&y\M:'" h1t~rn:1tionz1, inc. V\fr:e:.Jlu~K® is i =-~is!Bre:J t:<1i.ie:::a1~: Gf CoDp~: Tecf•. rr·o31e~ Co.:1t-'3n,-,·•t;nre,:. ~· i'-: G re)->tetc;:1 ·r:~;-:ef1':,(~ :f .A~1r~t"x ··· 0r ::oro- (0r1. ,t.J .. 1SEC(;,,ID i!:.~ s ="8!J::,.ter&d t:arJe:::ark 01 Put!~: E:lectn:; S:gnai (.o;np::.·n/. u.lC,. _t t-.f .... :z~) j ., ~~ t,t,'.>S°&~~...i rad~ma:► .. (:~. ~:':':f.ril,;a:; "~L t:r·rr;..:f Country of Origin: USA @) NOTI Fl ER® by Honeywell LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7315-0028:0513 7315 --POWER UNITS NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models PSE-6, PSE-6E, PSE-6R, PSE-10, PSE-10E, and PSE-10R Power Supply Expander. Model ZNAC-PS Class A Converter Module. The PSE series are remote power supply and battery charger units which also provide programmable synchronized Class B NAC's. Model Variations: All PSE-6 Models: Maximum 6A Capacity; 5 Class B NAC's; 2 Command Inputs; Trouble and AC Loss Relays All PSE-10 Models: Maximum 1 0A Capacity; 7 Class B NAC's; 3 Command Inputs; Trouble and AC Loss Relays With Suffix "E": Nominal 240V, 50/60 Hz AC Input Without Suffix "E": Nominal 120V, 50/60 Hz AC Input With Suffix "R": Red Enclosure Without Suffix "R": Black Enclosure Model ZNAC-PS: Optional Class A Conversion Module Refer to listee's printed data sheet for detailed product description and operational considerations. Models PSE-6 and PSE-6R: 120V AC, 50/60 Hz, 5.0A Maximum Models PSE-6E: 240V AC, 50/60 Hz, 2. 7 A Maximum Models PSE-10 and PSE-10R: 120V AC, 50/60 Hz, 6.2A Maximum Models PSE-10E: 240V AC, 50/60 Hz, 3.5A Maximum Model ZNAC-PS: 24V DC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a power supply extender when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 09-16-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 FDU-80 80 Character Liquid Crystal Display General The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the EIA-485 termi- nal port of each FACP. The FDU-80 requires no programming, which saves time during system commissioning. Features • SO-character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. • System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. • No programming necessary -FDU-80 connects to the ter- minal porton the FACP. • Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. • Time-and-date display field. • Aesthetically pleasing design. • May be powered from the host FACP or by remote power supply (requires 24 VDC). • Up to 32 FDU-80 annunciators per FACP. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. • Local piezo sounder with alarm and trouble resound. • Semi-flush mounts to 2.188" (5.556 cm) minimum deep, three-gang electrical box (NOTIFIER PN 10103) or three- gangable electrical switchbox. • Surface-mounts to NOTIFIER PN SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate system status, and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. DN-6820:B • D-123 @)NOTIFIER® by Honeywell Annunciators 6820fdu8.jpg Ordering Information FDU-80: 80 character, backlit, LCD Fire Annunciator with con- trol switches for remote control of system functions, and key- switch lock. FDU-SOC: ULC-listed version; see DN-60573 for details. 10103: Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635 • MEA Listed: 245-00-E • FDNY: COA#6038 • CSFM: 7120-0028:209 • FM Approved NOTE: For ULC-listed version, see DN-60573. DN-6820:B • 05/17/2010-Page 1 of 2 ISO 9001 19 §1-i il=ii ¥1 ·) ENCIIIEIINC I MMIFKTIRING QUALITY SYSTEMS NOTIFIER® is a registered trademark of Honeywell International Inc. ©201 O by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161 , FAX: (203) 484-7118. www.notifier.com ~ Made in the U.S. A Page 2 of 2 -DN-6820:B • 05/17/2010 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7120-0028:0209 7120 --ANNUNCIATORS NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models FDU-80 and *FDU-80G remote fire annunciators. Units are compact BO-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. *Rev. 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 SIGNALING ® LISTED FIRE ALARM DOCUMENTS Records / Programs I Software Standard Features: • Installed with a 4 gig digital flash drive with USB B connector • 2 Key ring hooks to hold system keys • Business card holder for key contacts • Overall Dimensions are 12" x 13" tall and 2 ¼ deep • 16 gauge steel box and cover for security • Durable powercoat baked on finish other colors available • Standard ¾"cat 30 key lock other lock as- semblies available • Solid stainless steel piano hinge • Permanently screened white ink 111 high "Fire Alarm Documents" • Legend sheet for passwords and system information FAD ACE-11 FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FOB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Ii] NFP.4 MEMBER -~ Madeln'e Space Age Electronics, Inc. www.tsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! ~SPACE AGE _,ELECTRONICS, INC./ Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1 /2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! USB Storage Interface Requires Standard USB-B Connector Property lnformat,on Minimum Required Oocumentat,on (SIG-FUN) :f:<cr,,.1t."Cl(1t. 1':F:>~.-71 ~!C1l ~U"l1 '!.'l 1; Key Ring Hooks =·~p.-.):,t;,-ty: __ _ 1 \'i~r;_::;,•~=~;\~~r~:.:~~)-'ll,H"'--ih<A-1?!'--" ___ _ °"s..rµ1;,,,.:~rr>"'I~~),-__ o~ ... ::l,)il~ .. y~-p.. Certifications and Approvals 16.1 System lnsi1.1tlation Ccntractor: ·r;..-.,.•y•litm,a.~ .. l,'ldt~.ar-.twtit'-•ertll"il!!l!o.:an..t 1 .. !tl .. rlacC'OrC.W-J;oJ1::.Cn•,\i;::~arc1in:OJ:": ... .re:•• ;~J::, .. 1·_"&fJ',t-_ -- Dafo __ ,· i O"7orr"°M.o~ ___________ _ :t:~.,_--__ 16.5 Aulhonty Ha,;ng Jurisdiction: lh .. \,.·trl!! .. ~.da111:!f11tetnr.1tl'~.a1:t.i,tn1n!1;>.s. 1'\<tt..c .. r.d"!oo,•1,. .. e1w::· ·o1 .. 1·~111n,;;vf')fl',,-,. ln~·---,r:-:a.·· /tih -~fiX'"~9cil)::)ll!ii .l9v~';..•\':xi'l. N::-~1::i.~:~:::~ -:;.tlf~ r-,e.·e:n" ,:,:x1•-l:~:◄tt-~tr•I ..... 1:-~:1 ~·p!J-.... ,-- 0;,:11 ·---·•-'·•····· .. ··-···· )•--.xY.~111,,,~ __ _ :::(:·_--__ Equipment Information ~':;;.'=---n ?F.n,x:.,• 111rtt'••'· t·itr s wiJ m.>·-:·· cl, unv."t.'4t.:v, 1n ,.~-~rd,l.~ca .,,•Ji fn,•••x: '7 -~ ~ ;f,!$::0 "ki" '.;ll4r'I\ E::<k:11::'1 Ci 1.:1 t,x-,.,:Y.◄, •. 1;}1';o:·· ~~-, .... --- Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED04 79 for legal disclaimer ED0549 LT10559 Rev.D 2/2 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300;.0553:0110 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SPACE AGE ELECTRONICS58 Checkett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@1sae.com Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IF1, IFX/A and IFX/D enclosures. Models ACE-11 , ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, * ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. listee's name, model number and UL label. Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 de This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 Intelligent Plug-In Photoelectric Smoke Detectors General The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951 Risa remote test capable detector for use with DNA Series duct detector housings. FSP-951 series detec- tors are available for both Flash Scan® and CLIP applications as designated. Features • New modern profile for improved aesthetics. • Designed to meet UL268 7th Edition. • Stable communication technique with noise immunity. • Low standby current. • Two-wire SLC connection. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Optional remote, single-gang LED accessory. • Dual LED design provides 360° viewing angle. • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan sys- tems only). • Remote test feature from the panel. • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (F/ashScan systems.only). • Built-in functional test switch activated by external magnet. • Built-in tamper-resistant feature. • Sealed against back pressure. • Expanded color options. • SEMS screws for wiring of the separate base. • Optional relay, isolator, and sounder bases. Specifications Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration. Size: 2.0" (5.3 cm) high; base determines diameter. -B300-6: 6.1" (15.6 cm) diameter. -8501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4oz (96.4g) Operating Temperature range: • FSP-951 , 0°C to 50°C (32°F to 122°F). • FSP-951T, 0°C to 38°C (32°F to 100°F). DN-60977:A ~NOTIFIER® by Honeywell Intelligent/Addressable Devices FSP-951 in B300-6 Base • FSP-951 R installed in a DNR/DNRW, -20°C to 70°C (-4°F to 158°F). UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPL/CATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 200µA @ 24VDC (one communica- tion every five seconds with LED enabled). LED Current (max.): 4.SmA@ 24 voe ("ON"). Installation FSP-951 series plug-in detectors use a separate base to simplify installation, service, and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B'? wiring. 2) When using relay or sounder bases, consult the /SO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60977:A • 4/17/18 -Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document. In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listed: S911 • FM Approved • CSFM: 7272~0028:0503 Product Line Information NOTE: • Detectors must be mounted to one of the Intelligent Bases listed below. • ''.A" suffix indicates ULC Listed model. • "IV" suffix indicates FlashScan® and CLIP device. FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- can only. FSP-951A: Same as FSP-951 but with ULC listing. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. FSP-951A-IV: Same as FSP-951-IV but with ULC listing. FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only. FSP-951TA: Same as FSP-951T but with ULC listing. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. FSP-951 R: White, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FlashScan only. FSP-951 RA: Same as FSP-951R but with ULC listing. For use with DNRA. FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FSP-951 RA-IV: Same as FSP-951 R-IV but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6" base, standard flanged low-profile mounting base. B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed. B501-BL: Black, 4" standard European.flangeless mounting base. UUULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. Page 2 of 3 -DN-60977:A • 4/17/18 B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224B IA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 1 0% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21 0LP(A) base. TR300-IV: Ivory, replacement flange for B21 0LP(A) base. RA 1 00Z(A}: Remote LED annunciator. 3 -32 voe. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. ISO 9001 1➔=1-iilil=i·I ENGIPIEIING & MANUFACTURING QUALITY SYSTEMS Page 3 of 3-DN-60977:A • 4/17/18 ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-0028:0503 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models FSP-951, *FSP-951-SELFT, FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, *FSP-951T-SELFT, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similar except for population/depopulation of components on the Printed Wiring Board for the intended features. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. 24VDC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: Model B710LP (CSFM No. 7300-0028:0173); System Sensor Models B224BI, B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); B501, B210LP, B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. *The Models FSP-951-SELFT and FSP-951T-SELFT are not Listed for use in duct environments. Refer to manufacturer's Installation Manual for details. All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 1-27-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30J 2022 Addressable Manual Pull Station ·General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" ( 10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1 .3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. • Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g} • Normal operating voltage: 24 voe. • Maximum SLC loop voltage: 28.0 voe. • Maximum SLC standby current: ,~7~}µA. • Maximum SLC alarm current: §.Ji}A. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location DN-6726:D • H-240 (G})NOTIFIER® by Honeywell Intelligent/Addressable Devices The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 -159 on FlashScan® systems, 1 -99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word Fl RE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-1/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D • 4/13/2012 -Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be-in pro- cess. Consult factory for latest listing status. • UUULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA: 67-02-E. • CSFM: 7150-0028:Q:199: • FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). • BSMI: Cl313066760047. • U.S. Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ISO 9001 19¥1-iii=il#I·) ENClflEIINC I MANIFSTIRING QUALITY SYSTEMS ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com ~ Made in the U.S. A. Page 2 of 2 -DN-6726:D • 4/13/2012 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-0028:0199 7150--FIRE ALARM PULL BOXES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12LO, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-1/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 · FST-951 Series Intelligent Thermal (Heat) Detectors General The NOTIFIER FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and build- ing design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135°F/ 57°C fixed-temperature, rate-of-rise and a 180°F/88°C fixed high- temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as desig- nated. Features • Sleek and stylish contemporary design. • Advanced thermal technology for fast response. • Fixed temperature model (FST-951) factory preset to 135°F (57°C). • Rate-of-rise model (FST-951 R), 15°F (8.3°C) per minute. • High temperature model (FST-951H) factory preset to 190°F (88°C). • Addressable by device. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Two-wire SLC connection. • Visible LEDs "blink" every time the unit is addressed. • 360°-field viewing angle of the visual alarm indicators (two bi- color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device-type identification. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause )-1 ) . • Low standby current. • Built-in tamper-resistant feature. • Designed for direct-surface or electrical-box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and mainte- nance. • SEMS screws for wiring of the separate base. • Optional remote, single-gang LED accessory. • Optional sounder, relay, and isolator bases. Specifications Size: 2.0" (5.3 cm) high; base determines diameter. -8300-6: 6.1" (15.6 cm) diameter. -8501: 4" (10.2 cm) diameter. For a complete list of detector bases, see DN-60981 Shipping weight: 3.4oz (96.4g) Operating temperature range: • FST-951, FST-951R Series: -20°C to 38°C (-4°F to 100°F); • FST-951 H Series: -20°C to 66°C (-4°F to 150°F). DN-60975:A @})NOTIFIER® by Honeywell Intelligent / Addressable Devices FST-951 R in 8300-6 Base Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% -93% non-condensing. Thermal ratings: Fixed-temperature set point 57°C (135°F), rate-of- rise detection 8.3°C (15°F) per minute, high temperature heat 88°C (190°F). ELECTRICAL SPECIFICATIONS Voltage range: 15 -32 volts DC peak. Standby current (max. avg.): 200uA @ 24 VDC (one communica- tion every 5 seconds with LED enabled). LED current (max.): 4.5mA @ 24 voe ("ON"). Applications Use thermal detectors for protection of property. For further informa- tion, refer to 156-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Installation The FST-951 Series plug-in intelligent thermal detectors use a sepa- rate base to simplify installation, service, and maintenance. Installa- tion instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B'? wiring. 2) When using relay or sounder bases, consult the /SO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60975:A • 4/23/18 -Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document.In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listing: S2101 • FM Approved • CSFM: 7270-0028:0502 Product Line Information NOTE: ''A" suffix indicates ULC Listed model. NOTE: "-IV" suffix indicates FlashScan® and CLIP device. FST-951: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only. FST-951A: Same as FST-951 but with ULC listing. FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. FST-951A-IV: Same as FST-951-IV but with ULC listing. FST-951 R: White, low-profile intelligent rate-of-rise thermal sensor, Flash Scan only. FST-951 RA: Same as FST-951 R but with ULC listing. FST-951 R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, FlashScan and CLIP. FST-951 RA-IV: Same as FST-951 A-IV but with ULC listing. FST-951 H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only. FST-951 HA: Same as FST-951 H but with ULC listing. FST-951 H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP. FST-951HA-IV: Same as FST-951 H-IV but with ULC listing. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6" base, standard flanged low-profile mounting base. B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting qase, ULC listed. B3(l0-6-BP: Bulk pack of B300-6, package contains 1 0 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. 8200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. 8200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. 8200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. 8200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. 8200SRA-WH: Same as B200SR-WH with, ULC listing. 8200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21 0LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA 1 00Z(A): Remote LED annunciator. 3 -32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B3006(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN-60975:A • 4/23/18 -Page 2 of 3 ISO 9001 19=i;iil#IU·I ENGIIIEIINC & MANUFACTHING QUAllTY SYSTEMS Page 3 of 3 -DN-60975:A • 4/23/18 Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. Notifier® and Bayblend® is a registered trademark of Bayer Corp. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 72,?Q-0028:0502 7270 --HEAT DETECTOR NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models FST-951 , *FST-951-SELFT, FST-951 H, NH-200, NH-200H (fixed temperature) and FST-951 R, NH-200R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. Models FST-951, *FST-951-SELFT, and NH-200 (fixed temperature): 135°F Models FST-951H and NH-200H (fixed temperature): 190°F Models FST-951R and NH-200R (fixed temperature with rate of rise): 135°F In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. listee's name, model number, electrical ratings, and UL label. listed as heat detectors for use with Notifier base 8710LP (CSFM No. 7300-0028:0173); System Sensor bases B501, B210LP, B300-6, 8300-6-1S (CSFM No. 7300-1653:0109); 8224B1, B224RB (CSFM No. 7300-1653:0126); 8200S, B200SR (CSFM No. 7300-1653:0213); 8200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Revision 1-26-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 FMM-1 (A), FMM-1Q1 (A), FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan® General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101 (A) to be mounted in a single-gang box behind the device it monitors. FZM-1 (A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1 (A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 -159 on FlashScan loops; 01 -99 on CLIP loops. • LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 (A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 (A) can be used to replace MMX-1 (A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class DN-6720:C • H-220 @)NOTIFIER® by Honeywell Intelligent/Addressable Devices FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status ( open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1 (A) SPECIFICATIONS Nominal operating voltage: 15 to 32 voe. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 µA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:C • 10/06/2010 -Page 1 of 4 FMM-101 (A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address: 01 -159 on FlashScan loops; 01 -99 on CLIP loops. s: 0 -.J -.J ~ 't,' I .. 1-lJJ -.J 0 ::; @ 0::: The FMM-101 (A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 (A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-10l(A) can be used to replace MMX-101 (A) modules in existing systems. FMM-101 (A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-'open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101 (A) SPECIFICATIONS Nominal operating voltage: 15 to 32 voe. Average operating current:. 350 µA, 1 communication every 5 seconds, 47k EOL; 600 µA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: -40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 µA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Page 2 of 4 -DN-6720:C • 10/06/2010 Dimensions: 1.3" (3.302 cm) high x 2. 75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1 (A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 -159 on FlashScan loops, 01 -99 on CLIP loops. • LED flashes during normal operation; this is a programma- ble option. • LED latches steady to indicate alarm on command from control panel. The FZM-1 (A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1 (A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELA across terminals 8 and 9 for Style D application. FZM-1 (A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status ( open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1 (A) SPECIFICATIONS Nominal operating voltage: 15 to 32 voe. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 µA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" {3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM1 (A) Dual Monitor Module The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) JDC circuits ONLY. Style D (Class A) JDC circuits are NOT supported in any application. FDM-1 (A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 µA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 µA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1 (A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1 (A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. A_ CAUTION: L.!.l Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and -FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory f~r latest listing status. • UL: S635 • ULC: S635 • FM Approved • CSFM: 7300-0028:0219 • MEA: 457-99-E • U.S. Coast Guard: -161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) -161.002/42/1 (NFS-640: FMM-1/-101) • Lloyd's Register: -03/60011/E1 (FMM-1/-101, FZM-1) -94/60004/E2 (AFP-200: except FDM-1) -02/60007 (NFS-640: FDM-1) • FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1 (A): Monitor module, two-wire detectors. FDM-1 (A): Monitor module, dual, two independent Class B cir- cuits. SMBSOO: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:C • 10/06/2010 -Page 3 of 4 ISO 9001 IY#l;iilii=i·i ENClrtEIINC I MANIFKTIRING QUALITY SYSTEMS FlashScan® and NOTIFIER® are registered trademarks and FireWatch™ is a trademark of Honeywell International Inc. ©201 O by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Page 4 of 4-ON-6720:C • 10/06/2010 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 73()0~0028:0219 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101 , FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1 , FRM-1 control modules, and *FDRM-1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's dat_a sheet for additional detailed product description and operational considerations. 16-33 VDC Primary In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 FCM-1 (A) & laM1-•IA) Series Control and Relay Modules General FCM-1 (A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. • LED blink may be deselected globally (affects all devices). • High noise immunity (EMF/RF!). • The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct-dial entry of address 01-159 for FlashScan loops, 01 -99 for CLIP mode loops. • Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1 (A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan@ releasing applications. Construction • The face plate is made of off-white heat-resistant plastic. • Controls include two rotary switches for direct-dial entry of address (01-159). DN-6724:B3 @) NOTIFIER® by Honeywell Intelligent / Addressable Devices FCM-1(A) • The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. • The FRM-1 (A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1 (A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 voe. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 µA direct poll , 375 µA group poll with LED flashing, 485 µA Max. (LED flashing, NAC shorted.) DN-6724:B3 • 2/17/2011 -Page 1 of 2 Maximum NAC Line Loss: 4 voe. Contact Ratings for FRM-1 (A) External supply voltage (between Terminals T10 and T11 ): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, SOW. Drain on external supply: 1 . 7 mA maximum using· 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMBS00 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw:;;~}5,mA (LED on). Average operating current: 2S.Q µA direct poll; 255 µA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C}. Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm} wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMBS00 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S3705 (A version only) • FM Approved • CSFM: 73QQroo28:02.19 • MEA: 14-00-E • FDNY: GOA #6067, #6065 Current Maximum Load Rating Voltage Description 3A 30VOC Resistive 2A 30VOC Resistive .9A 110 voe Resistive .9A 12s voe Resistive .SA 30VOC Inductive (L/R=5ms) 1 A 30VOC Inductive (L/R=2ms) .3A 125 VAC Inductive (PF=0.35) Inductive 1.5A 25VAC (PF=0.35) Inductive .7 A 70.7VAC (PF=0.35) Inductive 2A 25VAC (PF=0.35) NOTE: Maximum (Speakers): 70. 7 V RMS, 50 W Product Line Information Application Non-Coded Coded Non-Coded Non-Coded Coded Coded Non-Coded Non-Coded Non-Coded Non-Coded NOTE:'~" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): lnteUigent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. · SMBS00: Optional Surface-Mount Backbox. CB500: Control Module Barrier -required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: • FCM-1 (A) Installation document /56-1169. • FRM-1 (A) Installation document 156-3502. • Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. • 19§1;1il=il=i·i ENllrtlEIIN; I MANIFSTIRING QUALITY SYSTEMS We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161 , FAX: (203) 484-7118. www.notifier.com Page 2 of 2 -DN-6724:B3 • 2/17/2011 Made in the U.S. A. LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300;0028:0219 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM-1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. 16-33 voe Primary In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 ~NOTIFIER® by Honeywell DNR(A) and DNRW Intelligent Photoelectric Duct Detectors The Notifier DNR(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectan- gular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against fall- ing dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute (0.5 -20.32 m/s), temperatures of -4°F -158°F (-20°C -70°C), and a humidity range of 0 -95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble sig- nal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier DNR(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accesso- ries. Features • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min -4,000 ft/min (0.5 mis -20.32 m/s) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4 °F -158°F, -20°C - 70°C) and humidity (0% -95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • Cover tamper signal • Increased wiring space with a newly added 3/4" conduit knockout • Available space within housing to accommodate mounting of a relay module • Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection • Remote testing capability • Requires com line power only • Accommodates an addressable relay module, sold separately, (FRM-1) for applications requiring a Form-C relay Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4°F -158°F (-20°C -70°C) Storage Temperature Range: -22°F -158°F (-30°C -70°C) Operating Humidity Range: 0% -95% relative humidity (non-con- densing) Air Duct Velocity: 100-4,000 ft/min (0.5 -20.32 m/s) Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed . DNR(W) housings with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORYCURRENTLOADSAT24VDC Device Standby Alarm RA100Z 0mA 12mA Max RTS151/RTS151KEY 0mA 12mAMax Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest list- ing status. • UL: S635, S3705 • ULC: S635 • CSFM: 3240-1653:0209 • FM approved Product Line Information NOTE: '~ suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photo_electric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4 rated. FSP-951 R(A)-IV: Remote test capable addressable low-profile pho- toelectric smoke detector; ivory; supports CLIP and FlashScan® protocols FSP-951 R(A): Remote test capable addressable low-profile photo- electric smoke detector; white; supports FlashScan protocol only FSP-951 (A)-IV: Addressable low-profile photoelectric smoke detec- tor; ivory; supports CLIP and FlashScan protocols FSP-951 R(A): Addressable low-profile photoelectric smoke detec- tor; white; supports FlashScan protocol only DCOIL: Remote test coil. Required for older DNR(W) duct detector housing DUCTCOV: Retrofit DNR cover for manufactured prior to April 2014 DN-60429:C2 • 11/7/2019 -Page 1 of 2 DUCTCOVW: Retrofit DNRW cover for manufactured prior to April 2014 DST1 (A): Metal sampling tube duct width up to 1 ft (0.3m) DST1 .5(A): Metal sampling tube duct widths up to 1 ft -2 ft (0.3 - 0.6m) DST3(A): Metal sampling tube duct widths up to 2 ft -4 ft (0.6 -1.2 m) DST5(A): Metal sampling tube duct widths up to 4 ft -8 ft (1.2 -2.4 m) DST1 0(A): Metal sampling tube duct widths up to 8 ft -12 ft (2.4 - 3.7 m) DH400OE-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RA100Z(A): Remote annunciator alarm LED RTS151 (A): Remote test station RTS151 KEY(A): Remote test station with key lock ISO 9001 Li'1m1l1 Ut:.;; QUlllTY SYSTEMS Important Notes • DNR(W) duct detector housings with a date code of 0013 or higher do not require a oeOIL or auxiliary 24 voe for remote test applications when used with a remote test capable detector. • DNR(W) duct detector housings with a date code of 0012 or ear- lier require a oeOIL and auxiliary 24 voe power for remote test applications. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. :i;,2.019 by-Hc:inf:;y;,veH bternaHon(;l Inc. i\ll righ!5 rr-;st:;:-1e.:-t Unauthorizeii usr•; of u·+; dc1cumer:t is ';tncHy prch:ti!tr-;a. Country of Origin: Mexico ~NOTIFIER® by Honeywell LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 3240-1653:0209 Page 1 of 1 3240 --DUCT SMOKE DETECTOR HOUSING/BASE System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. 24VDC In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, air velocity and UL label. Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 ~~SYSTEM \._~ SENSOR' Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modem aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of i 2-or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, i15, 150, and 1T7 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate st1orting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • · Listed for ceiHng mounting only Agency Listings SIGNALING ® LISTED S551.?. S4011 <8> \!•·✓!) APPROVED .f" . FM abpra·Jeli excep, ,n~i65a'll504 ,or ALERT muliels 113~1~~:00~ 3057383 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower curr-ent draws and modern aesthetics. With white and red plastic housings. wall and ceiling mounting options, System Sensor !...-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying instafation. Ali devices feature a plug-in design with rninimai intrusion into the back box. making instaliations fast and foolproof while virtually eliminating costly and time- consum:ng ground faults. To further sirnplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring; installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of ·12-or 24-volt operation, and a rotary switch for horn tones witt1 two volume selections. L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1 %-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also n1ount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and vvaH products. The notification appliance circuit \.Viring shall terminate at the universal mounting plate. Also. L-Series products, when used with the Sync•CircuifM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts: 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and ·120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered povv1er supply. Ceiling strobes and horn strobes st1all have field-selectable candela settings including 15, 30. 75, 95. 1·15, ·150, and 177. Strobe foe strobe stlall be a System Sensor L-Series Model ___ listed to UL 1971 and st1all be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination Tr1e ~10rn strobe shall be a System SEmsor L-Se(es Model ___ listed to UL 1971 and UL 464 and shall be approved tor fire protective service. The horn strobe shall be wimd as a primary-signaling notification appliance and comply with the Americans with Disabilities ,\ct requirements for visible signaling appliances, flasl1ing at 1 Hz over the strobe's entire operating voltage range. The strobe li~Jht shall consist of a xenon flash tube and associated lens/reflector system. Tt1e horn shall have two audibility options and an option to switch between a temporal three pattern and a non--temporal (continuous) pattern. These options am set by a multiple positon switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The modu1e shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature Humidity Range Strobe Flash Rate Nominal Voltage Operating Voltage Range2 Operating Voltage Range (MDL3) Input Terminal Wire Gauge Ceiling-Mount Dimensions (including lens) Ceiling-Mount Surface Mount Back Box Skirt Dimen~ions (SBBCRL, SBBCWL) Notes: 32°F to 120°F (0°C to 49°C) 10 to 93% non-condensing 1 flash per second Regulated 12 voe or regulated 24 DC/FWR 1 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) · 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) 12 to 18 AWG 6.8" diameter x 2.5" higt1 (173 mrn diameter x 64 mm high) 6.9'' diameter x 3.4" high ( 175 mm diameter x 86 mm high) 1. Full Wave Rectified (FvVR) voltage is a non-re➔gulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 ed. ;\VDS86800 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 ·154 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 -rn·1 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 r,Jon-Temportal Low 95 166 54 71 ·124 161 170 216 258 3.1 K Temporal High 111 ·154 69 94 147 163 184 229 257 3. 1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.·1 K Non-Temporal Low 103 ·159 54 88 131 ·155 187 217 259 16-33Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 f< Temporal High 108 135 179 200 225 255 289 3. 1 K Temporal Low 79 101 150 171 196 229 260 3. lK Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 l\'✓DSSG80G • L-Series Dimensions ',/6.83 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information · ... 6.92 -I 2.50 0 Ceiling Surface Mount Back Box Model Description Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe. Red PC2WL 2-Wire. Horn Strobe, White ~~SYSTEM C~ SENSOR.,; Ceiling Strobes SCRL SCWL SCWL--CLR--ALERT Accessories TRC-2 TRC-2W SBBCRL SBBCWL 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630--377 --6495 Strobe, Red Strobe, White Strobe. White. ALERT Universal Ceilin9 Trim Ring Red Universal Ceiling Trim Ring White Ceiling SurfacE~ Mount Back Box, Red Ceiling Surface Mount Back Box, White ©2017 Svstem St>risor Pmduct specifications s,ibjec, to change ,vithvt;; not,ce. Visit syste1nsens0r . ..:om fer ct;rrent prodL,CI inforrn2tit,n, inc!uttng tile fa,est versiGn o, tl1is ddta sh~\. 1WDS868C1 • G3i17 • L, ~~SYSTEM \._~ SENSOR' Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation tltnes and maximize profits with lower current draw and modem aesthetics. Features • Updated Modern Aesthetics • SmaH profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12-or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wali units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 voits • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING @ LISTED $551.? St011 <8> APPROVED FM approved excep, 'or AL.F..RT models 3057383, 3057072 (~~\ t~~ 1125·1653:0504 7135-1653:[)fu."3 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With v11hite and red plastic housings. standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs ,.vith minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground f au Its. To further simplify installation and protect devices frorn construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so instailers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24--volt operation, and a rotary swl'tch for horn tones with two volume selections. A\/DS865-C5 • 2/22/2018 • Page 1 L-Series Specifications Archttect/Engineer Specifications General L-Series standard horns. strobes, and horn strobes shall mount to a standard 2 x 4 x Fis-inch back box, 4 x 4 x '1'12-inch back box. 4-inch octagon back box, or double-gang back box. L-Senes compact products shall mount to a single-gang 2 x 4 x 17/a-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for ail standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuif"' Module accessory. shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. Wr1en used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and '17.5 volts: 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and ·120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including ·15, 30, 75, 95, ·1 10, 135, and 185. Strobe foe strobe shall be a System Sensor L-Series Model __ ._ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination Tr1e horn strobe sr1all be a System Sensor L-Series Model ______________ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and cornply with the Arnericans with Disabilities Act requirements for visible signaiing appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shaH operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes. the module shall silencEi the horns on horn strobe models over a single pair of wires. Tho module shall mount to a 411/if.. x 411/rn x 21/s-incri back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature :32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC ·o'r regulated 24 DC/F-WR 1 Operating Voltage Range2 8 to 17.s ·v (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.TW x 1.91"D(143mrnL x 119mmWx 49mrnD) Compact Wall-Mount Dimensions (including lens) 5.26'' L. x 3.46'' W x 1.91 " D (133 mm L. x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.T'W x 1.25"0 (143 mrn L x 119 rnrn W x 32 mrn D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 ed. /..VDS8G5-05 • ?!22!?.0 18 • ParJe 2 "' UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33Volts Candela DC DC FWR Sound Pattern dB Candela 15 88 43 60 Temporal High Range 30 143 63 83 Temporal Low 75 N/A 107 136 Non-Temporal High 95 N/A 121 155 Non-Temporal Low 1·10 N/1-\ 148 179 3.1 KHz Temporal High 135 ~✓/A 172 209 3.1 KHz Temporal Low -i85 N/A 222 257 3.1 KHz Non-Temporal High 3. ·1 KHz Non-Temporal Low Coded 3.1 KHz Coded UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd) 8-17.5 Volts 16-33Volts DC Input 15cd 30cd 15cd 30cd Temporal High 98 158 54 74 Temporal Low 93 154 44 6'-,) Non-Temporal High 106 166 73 94 Non-Temportal Low 93 156 51 71 3.1 K Temporal High 93 156 53 73 3. 1 K Temporal Low 91 154 45 66 3.1 K Non-Temporal High 99 162 69 90 3. ·1 K Non-Temporal Low 93 156 52 72 16-33Volts FWR Input 15cd 30cd 75cd 95cd Temporal High 83 107 156 177 Temporal Low 68 91 145 165 Non-Temporal High 111 135 185 207 Non-Temportal Low 79 104 15.7 "175 3.11< Temporal High 81 105 155 177 3. ·1 K Temporal Low 68 90 145 166 3.1 K Non-Temporal High 104 131 177 204 3.1K Non-Temporal Low 77 102 156 177 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3. 1 KHz Temporal High 83 88 88 6 3.1 l<Hz Temporal Low 76 82 82 -7 3.1 KHz Non-Ternporal Hi9h 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 • Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAG. If the NAC volta9e is held constant, the horn.output remains constantly on. 75cd 121 111 139 119 119 112 135 119 110cd 198 ms 230 197 196 . '186 230 199 High High 95cd 142 133 160 139 140 133 157 138 135cd 234 223 264 235 234 222 264 234 8-17.5 Volts 16-33 Volts DC DC FWR 39 44 54 28 32 54 43 47 54 29 32 54 39 41 54 29 32 54 42 43 54 28 29 54 43 47 54 42 43 54 110cd 135cd 185cd 162 196 245 157 184 235 182 211 262 162 190 239 164 190 242 160 '185 235 175 208 261 162 192 242 185cd 287 27·1 316 283 284 276 326 291 N/DS865-05 • 2/22/2018 • Page 3 L-Series Dimensions 5.27'' 133.9mm 3.46' ,-; 88mm A0548-00 Compact Strobe, Horn Strobe 5.67" (14.4cm) j 4.70" (11.94cm) 1.91' 48.5mm 1.25" 32mm 1.91" (4.85cm) 1.25" (3.18mm) Strobe, Horn Strobe A0:,50-00 L-Series Ordering Information Model Description Wall Horn Strobes P2RL 2-Wire. Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White 5.27" 133.9mm I ---.-- 5.67" 144mm P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 tils act Hom Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2--Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red. FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire. Horn Strobe, Red P4WL 4--Wire, Horn Strobe, White Wall Strobes SRL Strobe. Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe. Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White. ALERT 3.46' ~mm .t,0!',47-00 1.25' 32mm 5.38' (13.7 cm) 1.55" (3.9cm) A0$57-00 Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL ;.,. -1.25• 32mm 5.78" :14.68cm) 4.82' (12.24cm) ~ ~j j _,_ .. Horn />.0549-00 Wall Surface Mount Back Box SBBRLJSBBWL Model Description HRL* Horn, Red HWL..* Horn, Whi1e HGRL* Compact Horn. Red HGWL* Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: A.ii -P 1TiO(iels have a plain housing (no "FIRE" marking on cover). P..H -SP models have "FUEGO" rnarking on cover. A.ii -ALERT models have ".4.LERT" marking on cover. WHorn-oniy models are listed for wall or ceiling use. (4.69cm) ~~SYSTEM C~ SENSOR~ 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com <f)2Q1fi ~~vstem Sensor Prodt;Cl st~cilicatit'f>S s..1b1ec, to ct,a;,ge w1t>iout rict,ce. Visit syste1nsensor.c:om ,er ct;rrt!nt prrx:lLict 1nforin2tio,·,, 1nc1uttng ttle latest vers1or. r1! this a2ta sheet •6,VDS865-05 • 2/22/2018 " LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE . 7135-1653:0503 7135 --AUDIBLE DEVICES Page 1 of 2 System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com System Sensor Indoor 2-wire and-*4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DA V/D CASTILLO,, M.E., F.P.E. Fire ~ngineering Division Listmg Expires June 30, 2021 • RATING: INSTALLATION: MARKING: APPROVAL: SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Listing No. 7135-1653:0503 Page 2 of 2 Refer to listee's data sheet for detailed product description and operational considerations. 12 voe regulated and 24 VDC/FWR In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30; 2021 .. · I LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE '"l:~25~ 1ij~~;Q504 •t Page 1 of 2 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL,i§tWUand SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requ\rements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division • RATING: INSTALLATION: MARKING: APPROVAL: Listing No. 7125-1653:0504 Page 2 of 2 Regulated 12 voe setting: 8-17.5 voe Regulated 24 voe/twr setting: 16-33 voe In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 • • • • ~~SYSTEM '-.~ SENSOR" Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL. 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12-or 24-volt operation at 15 and 15i75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 voits • Rated frorn -40cF to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wal! mounting Agency Listings SIGNALING ® ~ MEA LISTED ~ S4011 (chirnes. horn s,robes, hGrnB) APPROVED approved S3593 (outooor and alert ,;trobes) 3023572 ME,1A52-05-E a ~ ·7;1~1()53:18-r(outocor strobes) 7125-1653: 188 (rlorn strobes. ch,,ne s,robesj 7135-1653:189 (rloms, chimes) SPECTR'Aiert A.&X,rA .. &,li,■I SpectrAlert Advance otters the broadest lino of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or cei!ing mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12-or 24-volt operation. horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring vvithout mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof-plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drnl holes for screw-in mounting. Plastlc and metal weatherproof back boxes come with '%-inch top and bottom conduit entries and %-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box. .. t SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns. strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting p:ate. Also, SpectrAlert Advance products, when used 1,,vith the Sync•Circuif' Module accessory, shall be pmvered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, ·1 2-volt-rated notification appliance circult outputs shall operate between 9 and 17.5 volts: 24-volt-rated notification app1iance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAert Advance products shall operate between --40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including ·15, ·15/75, 30, 75, 95, ·1 10, 1 ·15_ ·135, 150, 177, and '185. Strobe foe strobe shall be a System Sensor SpectrAlert Advance Model ___ listed to UL 1971 and shall be approved for fire protective service. foe strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lensireflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination Tr1e horn strobe shall be a System Sensor SpectrAlert Advance Model _____ iisted to UL 1971 and UL 464 and shall be approved tor fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage :-ange. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature ----40°F to 151 °F (---40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FVVR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17 .5 V ( ·12 V nominal) or ·16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG WallwMount Dimensions (including lens) 5.6 " L x 4.T'W x 2.5"0 (142 rnm L x 1 '19 mm W x 64 mrn D) Horn Dimensions 5.6"l._ x 4.T'W x i.3"0 (142 mm L x 1i9 mm W x 33 mm 0) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.T'L x 5. ·1 "W x 2.G" D (145 rnrn L x ·130 mrn W x 51 rnrn D) Notes: 1. Full Wave Rectified (F\J'/R) voltage is a non-regulated, time-varying power source that is used on some power supply and pane: outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 ed. AVDS01201 I • • , • UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33Volts Candela DC FWR DC FWR Sound Pattern dB DC Standard 15 123 128 66 71 Temporal High 57 Candela '15/75 '142 '148 77 81 Temporal Medium 44 Range 30 NA NA 94 96 Temporal Low 38 75 NA NA 158 153 Non-Temporal High 57 95 NA NA rn·1 176 Non-Temporal Medium 42 110 NA NA 202 195 Non-Temporal Low 41 ·115 NA NA 210 205 Coded High 57 High 135 NA NA 228 207 Coded Medium 44 Candela 150 NA NA 246 220 Coded Low 40 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33Volts DC Input 15 15/75 15 15/75 30 75 95 Temporal High 137 147 79 90 107 176 194 Temporal Medium 132 144 69 80 97 157 182 Temporal Low 132 143 66 77 93 154 179 Non--Temporal High 141 152 91 100 116 176 201 Non-Temporal Medium 133 145 75 85 102 163 187 Non-Temporal Low 131 144 68 79 96 156 182 FWR Input Temporal High 136 155 88 97 112 168 190 Temporal Medium 129 152 78 88 103 160 184 Temporal Low 129 151 76 86 101 160 184 Non-Temporal High 142 161 103 112 126 181 203 Non--Temporal Medium 134 155 85 95 110 166 189 Non-Temporal Low 132 ·154 80 90 105 161 184 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 16-33Volts DC Input 135 150 177 Temporal High 245 259 290 Temporal Medium 235 253 288 Temporal Low 232 251 282 Non-Temporal High 255 270 303 Non-Temporal Medium 242 259 293 Non-Temporal Low 238 254 291 Candela Derating For K series products used at low temperatures, listed candeia ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at-40"F 15 15/75 Do not use below 32°F 30 75 44 95 70 110 no 115 115 135 135 150 150 177 177 185 185 16-33Volts 185 FWR Input 135 150 297 Temporal High 215 231 297 Temporal Medium 209 224 292 Temporal Low 207 221 309 Non-Temporal High 233 248 299 Non-Temporal Medium 219 232 295 Non-Temporal Low 214 229 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Sound Volts Volts Position Pattern dB DC FWR DC FWR 1 Temporal Hit:Jh 78 78 84 84 2 Temporal Medium 74 74 80 80 3 Teniporal Low 71 73 76 76 4 Non-High 82 82 88 88 Temporal 5 Non-Medium 78 78 85 85 Temporal 6 Non-Low 75 75 81 81 Temporal 7t Coded High 82 82 88 88 gt Coded Medium 78 78 85 85 91 Coded Low 75 75 81 81 FWR DC FWR 55 69 75 49 58 69 44 44 48 56 69 75 50 60 69 44 50 50 55 69 75 51 56 69 46 52 50 110 115 212 218 201 210 198 207 221 229 207 216 201 210 210 218 202 206 194 201 221 229 208 216 202 211 177 185 258 265 250 258 248 256 275 281 262 267 256 262 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 88 88 99 98 86 86 96 96 83 80 94 89 93 92 100 100 90 90 98 98 88 84 96 92 93 92 101 101 90 90 97 98 88 85 96 92 tSettings 7, 8. and 9 are not available on 2-wire horn strobe. lNDSo:201 .. • SpectrAlert Advance Diagrams c:i: X:::J C:.X Cl r.::.x ::x:::i c::x: c:x:J ~a::=§ 5.6" Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Hom Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK•T 2-Wire Horn Strobe. Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe. Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe. High ed. Red, Outdoor (includes plastic weatherproof back box) Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK1 Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red. Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: • Add "-P" to model number for plain housing (no "FIRE" marking on cover). e.g., P2RK-P. t Add "-R" to moc.iel number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flusr1 mounting plate, WTP and WTPW. "Standard cd'' refers to strobes that include 15, 15/75, 30. 75, 95. 110, and 115 candela settings. "High ed .. refers to strobes that include 135, 150. 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. ~~SYSTEM C~ SENSOR'! 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 Syslenl s~ns1..Jr Prt"'.itcd Sf"'lcilications s,ibjec\ to charge wiL~out nclcce. Visit systernser'Sl'r.,:om 1nr Ct;rrent prodv;t information, inckKtng the late~i version oi tt1is d,'!ta sh~t. AVDSt11201 • 3/12 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1653:0187 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of 1 System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 66°C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall}, SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. 8-17 .5 or 16-33 VDC/FWR In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires ·.· June 30, 2022