Loading...
HomeMy WebLinkAboutDWG 484-5U; CT 15-05; QUARRY CREEK PA R-3 MODELS; 01-15GENERAL NOTES RECYCLED WATER NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 2. DRINKING WATER FOUNTAINS ANO DESIGN A TED OUTDOOR EA TING AREAS SHALL BE PROTECTED AGAINST CONTACT WITH RECYCLED WATER SPRAY, MIST OR MISTING. 3. BEST MANAGEMENT PRACTICES SHALL BE USED TO ELIM/NA TE OR CONTROL TO THE BEST EXTENT POSSIBLE PONDING, RUN-OFF, OVER-SPRAY, ANO MISTING. 4. HOSE BIBS ARE STRICTLY PROHIBITED. 5. CROSS-CONNECTIONS BETWEEN RECYCLED WATER LINES AND POTABLE WATER LINES ARE STRICTLY PROHIBITED. 6. NO SUBSTITUTION OF PIPE MATERIALS WILL BE ALLOWED WITHOUT PRIOR APPROVAL OF THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICT. 7. ALL MAINLINE PIPES SHALL HAVE WARNING TAPE PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 8. HOURS FOR /RR/GA TJON WITH RECYCLED WATER ARE FROM 10: 00 P.M. TO 6: 00 A.M. THE HOURS FOR /RR/GA T/ON WITH 0/SJNFECTEO TERTIARY RECYCLED WATER MAY BE MODIFIED BY THE LOCAL AUTHOR/TY. /RR/GA T/ON DURING PUBLIC USE PERIODS WITH DISINFECTED TERTIARY RECYCLED WATER $HALL BE UNDER THE SUPERVISION OF THE DESIGN A TED USER SUPERVISOR. /RR/GA TION WITH WATER OF A LESSER QUALITY THAN DISINFECTED TERTIARY RECYCLED WATER SHALL BE BETWEEN THE HOURS OF 10: 00 P.M. TO 6: 00 A.M. 9. BURIAL OF ALL WIRING AND PIPING SHALL MEET CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 10. NON-OES/GNA Trn USE AREAS SHALL BE PROTECTED FROM CONTACT WITH RECYCLED WATER. WHETHER BY WIND BLOWN SPRAY OR BY DIRECT APPLICATION THROUGH /RR/GA TION OR OTHER USE. LACK OF PROTECTION, WHETHER BY DESIGN, CONSTRUCTION PRACTICE OR SYSTEM OPERATION IS STRICTLY PROHIBITED. 11. IRRIGATION HEADS SHALL BE RELOCATED OR ADJUSTED TO MINIMIZE OR ELIMINATE OVER- SPRA YING ON S/OEWALKS, STREETS AND NON-OES/GNA TED USE AREAS. 12. RECYCLED WATER QUICK COUPLING VALVES SHALL BE OF A TYPE DESIGNED FOR THE USE ON RECYCLED WATER DISTRIBUTION SYSTEMS PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 13. ON RECYCLED WATER SYSTEMS, ALL APPURTENANCES (SPRINKLER HEADS, VALVE BOXES, ETC.) SHALL BE COLOR-CODED PURPLE PER AWWA GU/OELINES AND SECTION 176815 OF THE CALIFORNIA HEAL TH AND SAFETY CODE. 14. ALL JRRIGA TION PIPE SHALL BE STENCILED WITH WARNING. "NON-POTABLE OR RECYCLED WATER", COLOR-CODED (PURPLE) AND LAID WITH WARNING TAP£ AND STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH PER THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULA TJONS. 15. ON NEW ON-SITE SYSTEMS (POST-METER). POTABLE WATER, CONSTANT PRESSURE RECYCLED WATER AND SEWER LINES SHOULD BE PLACED A MINIMUM OF FOUR FEET APART OR AS DIRECTED BY THE PROJECT ENGINEER AND/OR REGULA TORY AGENCY. MEASUREMENTS SHALL BE BETWEEN FACING SURFACES, NOT PIPE CENTERLINES. 16. CONSTANT PRESSURE RECYCLED WATER LINES SHALL CROSS AT LEAST TWELVE INCHES BELOW POTABLE WATER LINES AND MAINTAIN AT LEAST TWELVE INCHES CROSSING SEPARATION BETWEEN OTHER UTILITIES. 17. IF A 1CONSTANT PRESSURE RECYCLED WATER LINE MUST BE INSTALLED ABOVE A POTABLE WATER LINE OR LESS THAN TWELVE INCHES BELOW A POTABLE WATER LINE, THEN THE RECYCLED WATER LINE SHALL BE INSTALLED WITHIN AN APPROVED PROTECTIVE SLEEVE AS PER THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS 18. THE REQUIRED CROSS-CONNECTION SHUIDOWN TEST SHALL BE DONE BY THE CARLSBAD MUNICIPAL WATER DISTRICT AND THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. 19. THE REQUIRED CROSS-CONNECTION INSPECTION SHALL BE DONE BY EITHER THE CARLSBAD MUNICIPAL WATER DISTRICT AND/OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. COPIES OF INSPECTION REPORTS WILL BE FORWARDED TO THE NON-INSPECTING PARTY. 20. THE DESIGN AND LOCATIONS PROPOSED FOR RECYCLED WATER "DO NOT DRINK" SIGN SHALL BE CALLED OUT ON THE PLANS. 21. WHEN RECYCLED WATER BECOMES AVAILABLE, AN ON-SITE USER SUPERVISOR SHALL BE DESIGNATED IN WRITJNG. THIS INDIVIDUAL SHALL BE FAMILIAR WITH PLUMBING SYSTEM WITHIN THE PROPERTY, WITH THE BASIC CONCEPTS OF BACKFLOW/CROSS-CONNECTION PROTECTION. THE RECYCLED PUREYOR'S RULES AND REGULATIONS AND THE SPECIFIC REQUIREMENTS OF A RECYCLED WATER SYSTEM. COPIES OF THE DESJGNA T/ON, WITH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE CARLSBAD MUNICIPAL WATER DISTRICT. IN CASE OF EMERGENCY CONTACT JOHN SUSTER AT (85B) 458-9700 OR AFTER HOURS CONTACT JOHN SUSTER AT (760) 607-2319 22. ALL PUBLIC AND PRIVATE POTABLE WATER MAINS INCLUDING FIRE MAINS AND ANY WATER WELLS AND WATER COURSES WITHIN THE RECYCLED WATER PROJECT SHALL BE SHOWN ON THE PLANS. 23. CALL OUT ON THE PLANS IF THERE ARE OR ARE NOT DRINKING FOUNTAINS AND/OR DESIGNATED OUTDOOR EA TING AREAS ON THE SITE. 24. A PHYSICAL SEPARATION SHALL BE PROVIDED BETWEEN ADJACENT AREAS IRRIGATED W/Trl RECYCLED WATER AND POTABLE WATER. SEPARATION SHALL BE PROV/OED BY DISTANCE, CONCRETE MOW STRIPS OR OTt-lER APPROVED METHODS. 25. ALL /RR/GA TION BACKFLOW PREVENTERS SHALL BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE GIVEN TO Tl-IE CITY AND THE CARLSBAD MUNICIPAL WATER DISTRICT. PIPE BETWEEN THE METER AND BACKFLOW PREVENTER SHALL BE "SCHEDULE K HARD COPPER", APPROVED CONTRACT BACKFLOW TESTERS CAN BE FOUND ON THE CITY WEB WWW CARLSBADCA. GOV/SER VICES/DEPARTMEN TS/\VA TEP/DOCUMENTS/ RECYCLED WA TERBACKFLOWTESTERLIST.POF FOR RECYCLED OR WWW. CARLSBADCA. GOV /SER VJCES/DEPAR TMEN TS/\VA TER/DOCUM[N TS/ WA TERBACKFLOWTESTERLIST PDF FOR POTABLE OR CALL 438-2722. SIGNAGE NOTES RECLAIMED WATER SYSTEM PRIVATE QUARRY CREEK PA R-3 MODELS LANDSCAPE PLANS Vicinity Map Not To Scale THE FOLLOWING GUIDELINES FOR THE USE OF RECYCLED WATER ARE TO BE PERMANENTLY POSTED INSIDE THE DOOR OF EACH CONTROLLER WHERE THEY ARE EASILY VISIBLE. PLACE ON 8-1 /2" X 11" SIZED SIGN. COLOR.-PURPLE BACKGROUND WITH BLACK LETTER/NG. 1. GUIDELINES FOR RECYCLED WATER USE A. !RR/GA TE BETWEEN THE HOURS OF 10: 00 P.M. AND 6: 00 A.M. ONLY. WATERING OUTSIDE THIS TJME FRAME MUST BE DONE MANUALLY WITH QUALIFJED SUPERVISORY PERSONNEL ON-SITE. NO SYSTEM SHALL AT ANY 11ME BE LffT UNATTENDED DURING USE OUTSIDE THE NORMAL SCHEDULE. 8. IRRIGATE IN A MANNER THAT WILL MINIMIZE RUN-OFF. POOLING. AND PONDING. THE APPLICATION RATE SHALL NOT EXCEED TH£ INFILTRATION RATE OF TNE SOIL. TIMERS MUST BE ADJUSTED SO AS TO 8£ COMPATIBLE WITH THE LOi\!cST SOIL INF/L TRA TION RA TE PR[SENT. THIS PROCEDURE MAY BE FACIUTA TED BY THE EFFICIENT SCHEDULING OF THE AU TOMA TIC CONTROL CLOCKS. (I.E .. EMPLOYING THE REPEAT FUNCTION TO BREAK UP THE TOTAL IRRIGATION TlME INTO CYCLES TNAT WILL PROMOTE MAXIMUM SOIL ABSORPTION). C. ADJUST SPRAY HEADS TO ELIMINATE OVERSPRAY ONTO AREAS NOT UNDER THE CONTROL OF THE CUSTOMER FOR EXAMPLE, POOL DECKS, PRIVATE PATIOS ANO LOTS. AND STREETS AND SIDEWALKS. D. MONITOR ANO MAINTAIN THE SYSTEM TO M/NJM/ZE EQUIPMENT AND MATERIAL FAILURE. BROKEN SPRINKLER HEADS, LEAKS, UNREUABLE VALVES, ETC., SHOULD BE REPAIRED AS SOON AS THEY BECOME APPARE:NT. E. F. G. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR £DUCA TING EACH EMPLOY££ AND ALL MAINTENANCE PERSONNEL ON A CONTINUOUS BASIS, REGARDING THE PRESENCE OF RECYCLED WATER. MAINTENANCE PERSONNEL MUST BE INFORMED THAT WATER JS FOR /RR/GA TJON PURPOSES ONLY AND JS NOT APPROVED FOR DRINKING OR FOR HAND AND TOOL WASHING. ETC. OBTAIN PRIOR APPROVAL OF ALL PROPOSED CHANGES AND MOOJFICA TIONS TO ANY PRIVATE ON-SITE FACILITIES. SUCH CHANGES MUST B£ SUBMITTED TO, ANO APPROVED BY, THE DISTRICT ENGINEERING OFFICE AND DESIGNED IN ACCORDANCE WITH DISTRICT STANDARDS. 1. 2. ALL RECYCLED WATER SPRINKLER CONTROL VALVES SHALL BE TAGGED W/7H /DENT/FICA 110N TAGS. A. TAGS SHAU BE i\£ATNERPROOF PLASTIC, J"x 4". PURPLE IN COLOR. WITH /Ht WORDS "WARNING RtCYCLED WATER -DO NOT DRINK" IMPRINTED ON ONE SIDE. AND "AV/SO -AGUA /MPURA-NO TOMAR" IMPRINTED ON THE OTHER SIDE IMPRINTING SHALL BE PERMANENT AND BLACK IN COLQR_ USE TAGS AS MANUFACTURED BY T_ CHRISTY ENTERPRISES OR APPROVED EQUAL. B. ONE TAG SHALL BE ATTACHED TO EACH VALVE AS FOLLOWS~ 1. ATTACH TO VALVE STEM DIRECTLY OR WITN PLASTIC T/£-WRAP OR 2 ArTACH TO SOLENOID WIRE DIRECTLY OR WITH PLASTIC nE-WRAP .f)E_ 3. ATTACH TO VALVE COVER WITN EXISTING VAL\.'E COYER BOLT. ALL SPRINKLER HEADS SHALL BE IDENTIFIED AS RECYCLED WATER SPRINKLER HEADS. EACH AUTOMATIC CONTROLLEI? AND ITS ASSOC/A TED EQUIPMENT SHALL BE IDENTIFIED WITH A SIGN BEARING THE WORDS "RECYCLED WATER USED FOR /RR/GA T10N" IN ENGLISH AND SPAN/Sri, WITH BLACK LETTERS 1» HIGH ON A PURPLE BACKROUND. THE SIGN SHALL BE PLACED SO THAT IT CAN BE READILY SEEN BY ANY OPERATIONS PERSONNEL UTILIZING lHE EQUIPMENT. ALL BACKFLOW PREVENTERS SHALL BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE GIVEN TO THE CITY AND THE WATER DISTRICT PIPE BETWEEN THE METER AND BACKFLOW PREVENTER SHALL BE "SCHEDULE K HARD COPPER"_ APPROVED CONTRACT BACKFLOW TESTERS CAN BE FOUND ON THE CITY MB SITE AT WWW.CARLSBADCA.GOV/SERVICES/DEPARTMENTS/\VA TEP/DOCUMENTS/ RECYCLEDWATERBACKFLOWTESTERUST.PDF FOR RECYCLED OR WWW. CARLSBADCA. GOV /SER VJCES/DEPAR TMEN TS/WATER/DOCUMENTS/ WA TERBACKFLOWTESTERLISTPDF FDR POTABLE OR CALL 438-2722. INSPECTION PROCEDURES 1. DISTRICT CONSTRUCTION INSPECTION SHALL INCLUDE: REQUIRED SEPARATION BETWEEN POTABLE ANO RECYCLED WATER LINES (HORIZONTALLY ANO VERT/CALLY). PIPE /DEN TIFICA TION. SLEEVING AT CROSSINGS 0 A. B. C. 0. APPROPR/A TE MATERIALS AND MARKINGS, INCLUDING PROPER QUICK COUPLERS 2. DISTRICT FINAL INSPECTION SHALL INCLUDE: A. SJGNAGE INSTALLED PER PLAN B. CON TROLLER STICKERS C. TAGGING OF VALVES 0. COVERAGE TEST AFTER COMPLETION OF THE SPRINKLER SYSTEM TO ENSURE PROTECTION OF AREA NOT APPROVED FOR RECYCLED WATER USE. £. ALL ASPECTS OF THE /RRIGA T/ON CONDITIONS INCLUDING WINDBLOWN SPRAY. RUNOFF ANO PONO/NG F. REQUIRED PROTECTION OF ALL RESIDENTIAL AREAS. G. REQUIRED PROTECTION OF WELLS, STREAMS. RESERVOIRS, ETC. H. CROSS-CONNECTION TEST IF REQUIRED I. COLOR CODED, LAMINATED CHARTS INSIDE EACH CONTROLLER. 3. ANNUAL INSPECTION SHALL INCLUDE, PROPERTY LINE • North Not To Scale NOTTO SCAL r-- 1 NOTE, A SEPARATE G-ITY REVIEV'l AND APPROVAL IS REQUIRED FOR ANY PORTIONS OF THESE FLANS REQUIRING A BUILDING PERMIT. C.lfY APPROVAL OF THESE PLANS IS FOR LANDSGAPE PLANTING AND IRRIGATION ONLY. KEY MAP LEGEND THERE ARE NO OUTDOOR DRINKING FOUNTAINS. DECORATIVE FOUNTAINS ONLY. OUTDOOR PATIOS HAVE ONLY SUB-TERRANEAN DRIP TUBING IRRl<SATION IN ADJACENT PLANTERS. ii:! POINT OF CONNECTION FOR RECYCLED V'IATER (METER AND BAGKFLOv'I PREVENTION) .... "DO NOT DRINK" SIGN LOCATIONS PROPOSED PLANTING AREAS USING RECYCLED V'IATER-MAINTAINED BY HOA ~ p,NDSc.i,c,< 0~ f" ,..,,,,, i'.<'~ Sheet Number Sheet Index Sheet Title Title Sheet 1 2 3 4-7 8 9-10 11-12 13 14 15 Construction Layout Plans Construction Legend, Notes Construction Details Irrigation Plans Irrigation Legend, Notes, Details Irrigation Specs Planting Plans Planting Legend, Notes, Details Planting Specs DECLARA /ION OF RESPONSIBLE CHARGE: I HEREBY DECLARE THAT I AM LANDSCAPE ARCHITECT DF WORK FOR THIS PROJECT, THAT I HA vE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF 7HJS PROJECT AS DEFINED IN SEC T!ON 6 703 OF TH£ BUSINESS AND PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH AND THE CITY OF CARLSBAD IS CONFINED TO REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED LANDSCAPE ARCHITECT OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAV[ BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVA TJON PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPRO 'AL RELATING TO LANDSCAPING FIRM NAME & A Of SS; HO S INC., 2442 AVE. SAN DIEGO, 92101 ATE: 10 28 16 CAPE ARCHITECT 1 I 718-9660 REGISTRATION NO S): RLA 2681 EXP/RATION OA TE, 3/31/17 WATER EFFICIENT LANDSCAPE DECLARATION I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND /RR/GA /ION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULA ONS. I HA vE PREPARED THIS PLAN IN COMPLIANCE WI TH THOSE REGULATIONS AND H LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WH BMITTJNG CONSTRUCTION DOCUMENTS I CERTIFY THAT THE PLAN IMPLEMENTS E REGULATIONS PROVIDE EFFICIENT USE OF WATER. JULIE BA FLOW DATE: 10/28/16 TESTING: ALL BACKFLOW PREVENTERS SHAU BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST B£ GIVEN TO THE CITY AND THE WATER DISTRICT. PIPE BETWEEN THE METER AND BACKFLOW PREVENTER SHALL BE "SCHEDULE K HARD COPPER". APPROVED CONTRACT BACKFLOW TESTERS CAN BE FOUND CALL 438-2722 INSPECTION PROCEDURES: INSPECTION PROCEDURES: INSPECTION OF TH£ PROJECT SHALL BE PERFORMED BY THE LANDSCAPE ARCHITECT OF WORK, OR HIS DESIGNATED AGENT. REFER TO THE SPECIF/CA TJONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS. FOLLOWING COMPLETION OF THE WORK. THE LANDSCAPE ARCHITECT OF 7HE WORK W1U CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMITTING THE "CERT/FICA TION OR COMPLETION .. FORM A REQUEST FDR THE FINAL LANDSCAPE JNSPECTJDN BY THE CITY MUST ALSO BE MADE BY CALLING THE INSPECTION REQUEST LINE_ "CERTIFICATION OF COMPLETION" EMAIL TO MIKEELLIOTT2@COX.NET LANDSCAPE INSPECTION REQUEST PHONE LINE· (760) 602-4602 PRIOR TO BEGINNING LANDSCAPE WORK: THE CONTRACTOR SHALL CONTACT THE DESIGNER OF WORK PRIOR TO BEGINNING LANDSCAPE WORK AND THE DESIGNER OF WORK SHALL REVIEW THE PROJECT UTILITY LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCREEN ALL UTILITIES FROM VIEW AND PROTECT ALL UTILITIES (ABOVE AND BELOW GRADE) FROM INVASIVE PLANT GROWTH AND ROOTS. NO TE: THERE AR£ NO PROPOSED WATER FEATURES COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH LAND AND WATER QUALITY DIVISION ~ ----z__ /;-30-/6 A. A COMPLETE INSPECTION THAT WILL COVER A-I OF THE DISTRICT FINAL INSPECTION REVISIONS MUST BE APPROVED BY PUBLIC HEALTH CITY ENGINEER ANO DISTRICT ENGINEER PRIOR TO IMPLEMENT A T!ON IN F ENGINEER, D PROPOSED PLANTING AREAS USING POTABLE v'IATER-N/A ~ ,c\~ 0 ~ '.'.,,\ ' /j ~ D ~))'/ ~ er '" - APPROVED FOR GLENN LEEKS DATE ENVIRONMENTAL HEALTH SPECIALIST TYPICAL SIGNS IN ORDER TO CONSCRVE WATH-l RECYCLED WATER IN USE ,.-~ DO NO I NO fOML EL AGUA 1o §1: DRINK -~ WASti f-lAND:'> AFWR CONt:rACfiNG LAVESE SUS MANOS D[SPU[S D[ USAR Hf' X 18" SIZE .032 /\LUMINUM, .060 ABS PLASTIC OR STICK ON VINYL SIGNS rla 2681 HOWARD:: •►"%ASSOCIATES" .-•~ <-,; landscape architecture 2442 second avenue san diego ca 92101 619 718 9660 REVISIONS MUST BE APPROVED BY PUBLIC HEAL TH ENGINEER, CITY ENG AND DISTRICT ENGINEER PRIOR TO IMPLEMENTATION IN FIELD. -BLACK LOGO PLJRPI.F R/\CKGROLJND 1 .. BLACK LETTERS 35· ~ ~======:v=======---------1----_-__ (_N._T_.s_.)_ / -------~--- WARNING RECYCLED WATER DO NOT DRINK 1 ECYCLED WATER WASH flANDS AFTER CONCTACTl~IG 7VESE SUS-MANOS DESPUES DE USAF, ~,~,~. -□-L_A_C_K_l_F-_T_T_F_R_S 12" X 35" SIZE .032 ALUMINUM, _060 ABS PLASTIC 1" lJU\CK I FTTFRS -· OR STICK-ON VINYL SIGNS z /ELD !NEER (ONLY v'IITHIN PRIVATE PATIO AREAS) ---RG-·-REGYCLED IRRIGATION V'<ATER MAINLINE NIA POTABLE IRRIGATION V'-IATER MAINLINE -Vi-Vi~ POTABLE V'IATER LINE ---HATCHLINE ~ RECYCLED V'-IATER METER @] POT ABLE JAIi;'\ TER METER CARLSBAD MUNICIPAL WATER DISTRICT DEVELOPERS NAME: CORNERSTONE COMMUNITIES ADDRESS: 4365 EXECUTIVE DRIVE /f.600 SAN DIEGO, CA 92121 ~/~ (858) 458-9700 ~ OFFICE: DISTRICT,J>NiEER A DATE PLAN PREPARED: BY: /v c'.''"::>-,, Ir PLANTING ~eV DATE ti ,\ lij~l/11 'f" "AS BUILT" ~ EXP DATE /4¢' AND IRRIGATION ONLY, OF Cl'\.,\< INCLUDING PRECISE TITLE DATE DATE, 08/25/2016 LOCATION OF PLANTING REVIEWED BY: DRAV'!N BY, EP/HH AREAS. ~ I SHfET I CITY OF CARLSBAD PLANNING DIVISION s OUARRY CREEK PA R-3 MODELS APPROVED /~, :}{ er: ~l~-lf' tz · ,.. C1.,:, PLANNING DATE OWN BY: I PROJECT NO. I DRAWING NO. DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: 15-05 484-SU ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: CT co co LO I co \ 0 N en ~ ....I ~'--"-' I i ; I I I 1'>4'-0" .. q_ '! I I I ! I (1 I ' ~--'--'-----~--,t<---,11'---~--IS'-0" I --+--~ • / / / I \_jf. ,: L ~ 11'>'-0" T'r'P. .• ,_ S'-0" T'r'P. , .-,•/ ~CJ ,I ' •. i I'--' i q'-o" rrP. e'-o" , .,._ _ _..,. \ \ \ / / / ! i r 's--~-----------··---------------------------------------·-··-----------·--··-··------·· ·-----· .. ----------------------·-1~ 10•-o" 1·-~·-· j j ,1 , ! --Q ' . I LOT 12 KEY MAP NTS \ North 1" = 10' 0 5' 10' 30' r I I l l j Scale 1" = 10' APPROVED FOR PLANTING AND IRRIGATION ONLY, "AS BUil T" INCLUDING PRECISE TITLE DATE DATE: 08/25/2016 LOCATION OF PLANTING REVIEWED BY: £'\.,-,NDSC4;:j,t DRAJl'IN BY, EP/HH AREAS. f{ef?:-;,.,, '",,;~ tf /· .,,.., ,;.-~ I SH2ET I CITY OF CARLSBAD ~ f3 -u' C,\ ' PLANNING DIVISION a:: ,.. "1"~ I --< s .,,-,;_ ..K ., •\I, 't DATE J -tr CONSTRUCTION PLAN FOR: l,f'/'\ ~!-'l,ll'7 ,r-~~-•m.,<#,' OUARRY CREEK PA R-3 MODELS OF Cf>-\.1~0 rla 2681 ':!HOWA • , ASSOC Ro··~ APPROVED ~:.:(, \y ~ ti\..Af-,2, ~-/Z·"T•C!.,, IATES•:-PLANNING DATE .z. ~, .;, ,; landscap e architecture DWN BY: PROJECT NO. DATE INrTIAL DATE INITlAL DATE INITV\L avenue 2442 second san diego ca 921 01 619 718 9660 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CllY APPROVAL I I DRAWING NO. CHKD BY: CT 15-05 RVWD BY: 484-5U \ cSENERAL GQNSJEIJGIIQN NQTf;S I. ALL EXl5TIN6 DIMENSIONS AND LOCATIONS OF EXl5TIN6 OBJECTS ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL EXl5TIN5 ELEMENTS PRIOR TO BID. 2. ALL C.ON5TRIJCTION SHALL CONFORM TO MINIMUM Sf'EblFICATION5 AND REG\JIREMENTS OF Rl:6IONAL, Loe.AL AND STATE 60v:El'<NMENTAL MENCIES. 9. OIIIINER SHALL APPROVE ALL MATERIALS PRIOR TO O~ERIN5. SUBMIT FINISH SAMPLES OF FLATmRK FOR Ol'INER APPROVAL f'B',!O&"TO ORDERIN6. 4. PERMITS FOR ANY CON5TRIJCTION DEPICTED IN THEpE />"C)O.N5 SHALL BE OBTAINED BY THE CONTRACTOR I c../ 5. CONTRACTOR SHALL SHIELD EXl5TIN5 ~RI< l'IITH VISG\JEEN TO PREVENT 5PLATTERIN6 OF CONCRETE OR MORTAR. Ii>. ALL PAVIN5 SHALL SURFACE DRAIN AT MINIMUM 1% A~Y FROM ~LL5 AND 5TRIJCTURE5 TO~RD Sl'IALES. ALL PLANTED AREAS SHALL DRAIN AT MIN. 2% TOl'IARD S~LES. SEE CIVIL EN61NEERIN5 DRAINA5E PLAN FOR ALL 5RADIN5. 7. ALL l'IRITTEN DIMENSIONS ON PLANS SHALL TAl<E PREGEDENCE OVER SCALED DIMENSIONS. e. IN CASE OF DISCREPANCIES BE'TYIIEEN ~ITTEN SPECIFICATIONS AND 5RAPHIC INFORMATION OR OTHER INFORMATION, THE CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT rOR CLARll"ICATION. GOHCtSEIE NQTE5 I. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE 5TREN5TH AT 2e DAYS Or 2!300 PSI. CEMENT SHALL BE TYPE I. FINISH MEDIUM BROOM FINISH AND COLOR SHALL BE 'NATURAL 5REY' UNLESS OTHEM15E NOTED. PROVIDE 12" SGUARE SAMPLE POUR l"OR APPROVAL PRIOR TO INSTALLATION. 2. REINFORCIN5 SHALL COMPLY l'IITH ASTM A615, 5RADE 40. 9. CONTRACTOR SHALL INSTALL rULL-DEPTH EXPANSION JOINTS AND SC.ORE JOINTS AS SHOl'IN ON PLANS AND DETAILS, AND ADD ADDITIONAL JOINTS l'IHERE Patio Surface Schedule ITEM PLAN# PATIO FINISH ' OUTDOOR PATIO 2 MARAZZI: CAMBRIDGE OAK 6" X 36" J\L6P -COLOR: BLACK. INSTALL STRAIGHT/STAGGERED; SAM EDIRECTION AS INTERIOR GROUT: TEC #935 SILHOUETTE OUTDOOR PATIO 1 DAL TILE: IMAGICA IG95 VISION uN'fok'.iSHED 24"X24" INSTALLED STRAIGHT. I f ) GROUT: TEC #988 PEARL 1 ,. OUTDOOR PATIO 3 ARIZONA TILE: FIND SERIES. COLOR. ASH 12"X24" INSTALLED STRAIGHT/STACKED; SAME DIRECTION AS INTERIOR FLOOR GROUT: TEC #934 DELOREAN GRAY NO'TE:, NECESSARY TO CONTROL CONCRETE CRACl<IN6. ______ _ ,. A~--Al.I-~'""'I"~ NOTES --------- A ~TER ErrlCIENT LANDSCAPIN5 EIROCHURE SHALL EIE AVAILABLE rOR EACH 5ROUP OF ADULTS Vl51TIN5 THE MODEL HOME. AT A MINIMUM, EACH BROCHURE SHALL INCLUDE INFORMATION DESCRIBING THE ~TER EFl"ICIENT rEATURES OF THE MODEL'S LAND5CAPIN5; RESOURCES rOR ADDITIONAL INl"ORMATION RE5ARDIN5 ~TER EFFICIENCY IN LANDSCAPIN5; CONTACT INFORMATION FOR THE LOCAL ~TER RJRVEYOR AND PLANNING DIVISION; AND A REFERENCE TO REQUIREMENTS Or THE LANDSCAPE MANUAL. A COPY OF THE EIROCHURE SHALL EIE PROVIDED TO THE PLANNIN5 DIVISION PRIOR TO THE CITY AUTHORIZIN5 TEMPORARY OCCUPANCY AS A MODEL HOME. ~L C'!IV' D-iDY r,q, --------·-1. ALL LIJM6ER SHALL SE DOU5LAS EJF.,W~2--GAAD!:C,i:t BETTER, UNLESS OTHE~15E.INDIGATED-:--;tr;tl.7R6ROUND POSTS SHALL BE REDmoo. -----2:··Att:"l:!J1'16ER SHALL BE ROU5H, UNLESS OTHE~ISE INDICATED. 9. ALL CONNECTORS, ANCHORS AND ACCESSORIES, INCLUDIN6 NAILS, SHALL BE STRUCTURAL STEEL AND SHALL BE HOT DIPPED 5ALVANIZED. ALL HARD~RE TO RECEIVE PAINT TO MATCH moo. 4. ALL moo OVERHEAD AND TRELLIS SURFACES SHALL BE PAINTED l'IITH ONE (I) COAT Or EXTERIOR PRIMER AND Tm (2) GOATS OF v,eATHER-RE515TANT ALKYD ENAMEL. COLOR SHALL MATCH ARCHITECTURAL TRIM UNLESS NOTED OTHEMl5E. PRIME PRIOR TO ASSEMBLY. 5. ALL 5ATES SHALL BE SELF-CLOSIN5 l'IITH STEEL STOPS. PROVIDE MASTER !<EYED LOCKS rOR ALL TRAP !"ENCE 5ATES. i"JOOP STAIN NOTES I. ALL S~ACES MUST 6E CLEAN, SOUND, DRY, AND rREE Or ANY DIRT, DUST, CHALi<, OIL, GREASE, AND MILDEl'I STAINS. 2. STAIN SHALL SE APPLIED IN ACCORDANCE l'IITH THE PRINTED INSTRIJCTION5 AND AT THE APPLICATION RATES RECOMMENDED BY THE MANUl"ACTURER. 9. CONTRACTOR SHALL APPLY Tl'IO COATS OF A SEMITRANSPARENT STAIN. EACH COAT SHALL BE APPLIED TO A UNll"ORM rlNISH. FINISHED SURFACES SHALL BE rREE Or SURFACE DEVIATIONS AND IMPERFECTIONS. 4. EACH APPLICATION OF STAIN SHALL BE CURED IN ACCORDANCE l'IITH THE MANUFACTURER.E'S REC.OMMENDATION5 BEFORE APPL YIN5 THE 5UCCEEDIN6 COAT. DRYIN6 TIME 6ETv,eEN APPLICATIONS SHALL BE AS RECOMMENDED BY THE MANUFACTURER 5. STAIN SHALL BE APPLIED BY 6RU5H, ROLLER, OR SPRAY. MASONRY NQJJ=S I. ALL STUCCO ~LL5 SHALL BE ~TER SEALED l'IITHIN SO DAYS OF STUCCO COLOR. ALL 5TUCC.O SHALL MATCH ARCHITECTURE IN FINISH, EXCEPT AS NOTED. METAL FENCINS NOTES I. ALL METAL FENCIN5 SHALL SE SEAMLESS STEEL TUSIN5, 5RADE B, CONl"ORMIN5 TO A5TM ASOl-81. 2. LANDSCAPE CONTRACTOR SHALL SECURE ALL FIELD MEASUREMENTS REGUIRED rOR PROPER AND ADEGUATE FABRICATION AND INSTALLATION Or FENCIN5. 9. METAL rENCIN5 AND GATES SHALL BE rABRICATED AND ASSEMBLED IN THE SHOP TO THE 5REATE5T EXTENT POSSIBLE. 4. ALL ~DS AND OTHER CONNECTIONS EXPOSED IN THE FINISHED l'IORI< SHALL BE <SROUND AND DRESSED SMOOTH AND 50 THAT THE SHAPE AND PROl"ILE OF THE ITEM l'IELDED 15 PRESERVED. 5. GATES SHALL RECEIVE HEAVY-DUTY 5PRIN5 LOADED HIN5E ASSEMEILIE5 l'IITH SELF-LATCHING HARD~RE. ALL 5ATE5 SHALL HAVE MASTER-KEYED LOCKS. 6, ALL SURFACES SHALL BE PRIME COATED l'IITH SYNTHETIC, RUST-INHIBITING PRIMER. FINAL rlNISH SHALL BE ELEGTROSTATICALL Y APPLIED OF Tm (2) COATS Or A LUSTERLESS ALKYD ENAMEL. THE COLOR SHALL EIE ARCHITECT PRIOR TO INSTALLATION. SELECTED BY THE LANDSCAPE 7. ALL 5ATE5 SHALL BE SELF-CL051N6 l'IITH STEEL STOPS. PROVIDE MASTER l<EYED LOCl<S FOR ALL TRAP FENCE GATES. SRAPIHS NQTf;S I. SEE CIVIL EN51NEER'S PRECISE 5RADIN5 PLAN AND DRAINA5E PLAN FOR ALL GRADES, SPOT ELEVATIONS AND DRAINA5E SYSTEM, 2. HARDSCAPE SHALL HAVE A POSITIVE SURFACE DRAINA5E OF MIN. 1% ~y rROM 5TRIJCTURES. PLANTIN5 AREAS SHALL DRAIN AT A MIN. 2% SURFACE DRAINA5E. SEE CIVIL EN51NEER PLANS rOR ALL AREA DRAINS AND Sl'IALES. NQ"Ce, EXTERIOR TILE PAVINS TO MATCH INTERIOR FLOORINS. CONTRACTOR,_f>.l:fhLL--·---·- CONrlRM SPECIFICATION l'IITH SITE SUPERINTENDJ=l',II.PR10R--TO--ORl5ERIN5 MATERIAL. ____________________ _ ---~--·------------- 0 0 0 0 0 0 0 © Construction Legend FEATURES rlREPLACE / TV CABINET, PLAN 2 © MASONRY BBG COUNTER, PLAN 1@ MASONRY 66G COUNTER l'IITH POT SHELi", PLAN 9 @· OVERHEAD TRELLIS @ rOUNTAIN (TYP. 01" 5). RIPPLED PILLAR UNDER5ROUND FOUNTAIN. BRONZE HERITA5E FINISH, #Hl<-50094BH. AVAILABLE, l'<l'<l'<.garden-Fountalns.c:som SET l'IITH TOP OF Iii>" BASIN AT F.S. AND COVER BASIN LID l'IITH 2" LAYER OF I" EILACI< JAPANESE BEACH PEBBLES. PROVIDE AUTO FILL ¼" DRIP TUBING TO EACH 6ASIN FROM POTABLE IRRl5ATION VALVE #A-6 AND PR05RAM CONTROLLER rOR PERIODIC FILL AS NEEDED. LOI'! l'IALL l'IITH ACCENT POT AND BENCH ® PARKINS AREA OVERHEAD TRELLIS @ PLANTER l'IALL PER PRODUCTION PLANS FENCIN6 @ 4:2" HIGH VINYL !"ENCE PER PRODUCTION PLANS @ 42" HISH VINYL GATE PER PRODUCTION PLANS (TYP. PLANS 142) @ TEMPORARY 6' HIGH VINYL rENci:@ @ TEMPORARY 6' HISH VINYL FENCE l'IITH 2' LATTICE PANEL TO SCREEN RESTROOM €3) TEMPORARY 42" TRAP FENCE® @ e' LEN6TH, 5' HT OF VINYL FENCE BETl'IEEN PLAN 2 COURTYARDS @ TEMPORARY S' l'IIDE TRAP FENCE MAINTENANCE SATE, TO MATCH FENCE FLATl"!ORI< AND PAVIN5 @ A5PHAL T HANDICAP PARKINS SPACE l'IITH STRIPIN5 4 51SNA5E AS REGUIRED EIY CODE ® TEMPORARY CONCRETE STOOP AND l'IALI< AT SALES OFFICE DOOR ® @ OMIT CONCRETE l'IALI< PORTION UNTIL MODEL CLOSE @ TEMPORARY A5PHAL T PARKING SPACES l'IITH 5TRIPIN5 AS SHOl'IN s TEMPORARY ACCENT CONCRETE PAVIN5 l'IITH 12" CONCRETE BANDINS -2X2 PATTERN A5 5HOl'IN, TOOLED JOINTS. COLOR TO BE DAVIS 'MOCHA', MEDIUM ACID-ETCH r1Nl5H. PROl"ILE PER CIVIL EN51NEER. C.ONCRETE ~LK PER PRODUCTION PLANS ·----------., _ ..... -~~~~----·------ DRl~?.i::£.f:l':.R.ENSINEER. f't"'~--- -€j}--~~ PATIO -SEE PATIO 5URl"ACE SCHEDULE@ LEFT@ @ ENHANCED PAVING PER PRODUCTION PLANS @) STEP RISER AT SATE PER EN51NEER SRADIN5 PLANS. MISCELLANEOUS PORTABL.E ADA-ACCE551EILE RESTROOM, BY OIIIINER ADA ACCESSIBLE PATH Or TRAVEL, MAX 5% SLOPE IN PATH Or TRAVEL, MAX. 2% CROSS SLOPE. SEE ENSINEER PRECISE GRADINS PLAN. SISNASE, SHALL BE l'IHITE l'IITH BLACK CAPITAL LETTERINS AT LEAST Tm INCHES HISH AND SHALL INCLUDE INFORMATION ABOUT THE SITE l'IATER USE AS DESIGNED PER THE IE\ LOCAL ORDINANCE; INCLUDING THE NAME Or THE PROJECT LANDSCAPE ARCHITECT, li;37 LANDSCAPE CONTRAC.TOR AND l'IILL DEMONSTRATE LOI'! ~TER USE APPROAC.HES TO LANDSCAPIN5. A.C. UNIT-TYP. EACH YARD (N.I.CJ 9" LAYER BARK MULCH IN COURTYARDS OF (S) UNITS NOT MODELED. TRENCH DRAIN -4" EILACI< PLASTIC TRENCH DRAIN 4 5RATE. CONNECT TO COMMON AREA DRAIN SYSTEM. 4" ATRIUM GRATE ON 4" RISER CONNECT TO COMMON AREA DRAIN SYSTEM. Je" SGUARE CUT-OUT FOR VINES. :2" LAYER Or I" BLACK JAPANESE EIEACH PEEIEILE· IN PLANTER APPROVED FOR ,, ~ ASSOC -landscape 2442 second san diego ca 9210 ~\.i'!'-iDSC,,,O~ .• , .AA t.tc: ~ ~ '"' '1ti,, s.: ~ 0 ~ ~ ... {it ,., ./ 1..1 Y\) _,,,. i'\i 'T\JRE -I t. '"'. r,.\r~ ~ DATE ;.* 09/Slfil ~ ,;:,...__ E>P. DATE--<#: OF Cl>-\.1~0 rla 2681 RD"· ,:;_,, .i,. I ATES"' architecture avenue 1 619 718 9660 DATE INITIAL ENGINEER OF WORK PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE DATE, 08/25/2016 LOCATION OF PLANTING DRAJIIIN BY, EP/HH AREAS. DATE INITIAL DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL "AS BUil T" TITLE DATE REVIEWED BY: I SH3IT I CITY OF CARLSBAD I sJE~s / PLANNING DIVISION CONSTRUCTION NOTES & LEGEND FOR: QUARRY CR££K PA R-3 MODELS APPROVED /¾d; ,, 4 f:;.l\~11--("7.-1-1 ~ PLANNING DATE DWN BY: I PROJECT NO. I DRAWING NO. CHKD BY: 15-05 484-5U RVWD BY: CT PEDESTRIAN GCNC,RLTL PAVIN6 -----~ TILL PAVIN6 ----. MORTAR BED-~ 6ROUT JOINT SIZE l'IILL VAr.:f' -~ I' MAX. COMPACTED ISRAVLL Tile Pavin Over Concrete Base l'-O" NOTTO SCALE ~~ ------ Q) 5x5 VINYL POST J.',IITH POST GAP (3} b" J.',IIDE TIIG VINYL PIC.KETS @ b" HIGH BOTTOM RAIL l"IITH ALUMINUM CHANNEL @ b" HIGH TOP RAIL @ C.ONCRETE FOOTING @ FINISH GRADE NOTES, ALL COMPONENTS TO BE 'KROY' SOLID FENCE - KROY.PL YGEM.C.OM, OR EGUAL AS APPROVED BY OJ.',INER. FENCE COLOR TO BE TAN I I '° I I 11) I = "" I - I\) IB" O.C. ~" lYP. CD 4X4 RESAJ.',IN POST @ IX4 TOP AND BOTTOM RAIL '° @ IX4 RESAJ.',IN VERTIC.ALS I ('{) @ 2X4 RESAJ.',IN SHAPED TOP RAIL TO MATC.H 5 "" ARCHITECTURE BALCONY RAILING ® FINISH GRADE @ CONCRETE FOOTING TRAP FENC.E ELEVATION TRAP fENC.E SEC.TIQN NOT TO 5c.ALE (~) Trap Fence ----< 5 , ...... ~ .. ' .. SECTION NOT TO SCALE . ,., .... ' 0 0 ® 0 ® 0 4" CONCRETE PAVING -2500 PSI @ 28 DAYS UNLESS OTHERV'llSE SPECIFIED 2" BASE IF REQUIRED BY SOILS REPORT OMIT COMP AC TED SUBGRADE 1/2" PREFORMED FELT EXPANSION JOINT V'llTH 1/4" RADIUS @ EDGES 1/4" SAV'lCUT OR TOOLED SCORE JOINT PER C.ONSTRUC.TION PLAN NOTE, ALL SUB-BASE AND REINFORCEMENT SHALL BE PER SOILS/STRUCTURAL ENGINEER. @)---c_o_n_cr_e_te_P_a_v_in_g _____________ ""!"N~Ts ~~DSCq,o,!' ~~o "a""~~ -!cl¼' .~ --"' ~ ' ~.,.,. ill ~~~i<,. \f '~ -1, DATE /. -1, ~ ,,..,..,~, ~ EXP. DATE-<~ OF C/>l.-I ~O rla 2681 ~:HOWA RD:: ., .,. ASSOC .• ,, "' I an d s c a p e 2442 second san diego ca 9210 !ATES~ architecture avenue 1 619 718 9660 DATE INIT~L ENGINEER OF WORK CD \ -, 0.. )- -C OJ @ I I -N • ..• • •• • • .. .;, : .. • • NOT TO SC.ALE @ @ (Di8"xl8" SIGN .. 032 ALUMINUM, .060 PLASTIC. @4"x4" D.F. POST @)CONCRETE FOOTIN& @FINISH GRADE SIGNAGE SHALL BE V'lHITE V'llTH BLACK CAPITAL LETTERING AT LEAST 2" Hl&H AND SHALL INCLUDE INFORMATION ABOUT THE SITE V'lATER USE AS DESIGNED PER THE LOCAL ORDINANCE; INC.LUDIN& THE SAME OF THE PROJEC. T LANDSCAPE ARCHITECT, LANDSCAPE C.ONTRACTOR AND l"IILL DEMONSTRATE LOV'l V'lATER USE APPROACHES TO LANDSCAPING (E) Low Water Use Signage APPROVED FOR PLANTING AND IRRIGATION ONLY, "AS BUILT" INCLUDING PRECISE TITLE DATE DATE, O8/25/2O1b LOCATION OF PLANTING REVIEWED BY: DRAY'IN SY, EP/HH AREAS. I SH4ET I CITY OF CARLSBAD ~ PLANNING DIVISION s CONSTRUCTION DETAILS FOR: OUARRY CREEK PA R-3 MODELS APPROVED ~ ,, &-~\~%-I .,, rz.-,.{~ PLANNING DATE OWN BY: I PROJECT NO. I DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: CT 15-05 REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RWID BY: 484-5U I I ' ' • I () i i _I I NI ! I ..1 __ 1., ---·-- ---------- <( --......, _j <( FRONT ELEVATION CD e," CMU l"lALJ..S IN ~NT 4 6AC;KSPL.A5H, 12" CMU IN 6AC;K. OS REl:lAR VERTICAL • 16" O.C. -5RGUT FILL ALL CELLS SOLID. (6AC;K 5PLASH VIALL -6' CMU). @ CONCRETE FOOTIN6 ~ITH #9 REBAR CONTINUOUS 60TH ~'1"5 o 16" o.c. @ STONE VENEER ON ~NT AND SIDES -coRONADO STONE PRO LEDeE 'HURON'. @) COUNTERTOP -CORONADO STONE le" >< 20" >< 2" "HeARTHSTONE", COLOR 'A5PEN'. CUT TO FIT @ 61:lG! UNIT -eRAND HALL ''TIJR60 4-1:llJRNER 6UILT-IN eAS <5,RILL". CUT OUT SIZE 90.5" ~ ,c l<f.15" DEEP >< q_5" Hlel-f. AVAILAl:lLE AT 6AR6EGUE5 eALORE, -.61:lG!eALORE.COM. @ 11" >< 20" STAINLESS STEEL SIN<SLE AC;CESS DOOR TO MATCH 61:lG! UNIT G) I ,c 4 TILE 6AC;K SPLASH -AZ SHIMMER eLASS TO MATCH KITCHEN PLAN I. COORDINATE TILE 5PECIFICATION AND ~ASE ~ITH SITE 51./PS<.INTENDENT @ FINISH SURFAC;E CONCRETE PATIO @) VINYL FENCE -SEE CONSmJCTION PLAN @ COMPAC;TED SU6-6RADE @ 6ACK SPLASH CAP -CORONADO STONE 'I" ,c le>" >< 2 :I" (CUT TO FIT) "SPLIT-EDeE ~L CAP", COLOR 'ASPEN' NOTES, I. CONTRACTOR SHALL COORDINATE NA11.JRAL. GAS LINE AND NECESSARY S" • () I <'I VOID N 96" SECTION A-A BBQ Counter -Plan 1 PERMITS. @1----------------------------------------------NOT'!!!!!''!!!'TO!!"S!"!Q,."J.E~ PLAN VIEW EGUAL 000 . -- FRONT ELEVATION @) BBQ Counter -Plan 3 EGUAL 5 5 --..--~-1 -,-- ' ' I I I ! I I I I ! I I I I CD e" cMu ~LLS V'IITH #S REBAR VERTICAL @ 16" o.c. -CSoROUT FILL ALL CELLS SOLID. @ CONC.RETE FOOTINCSo f,',fTH #S REBAR CONTINUOUS BOTH ~YS @ 16" O.C. @ STONE VENEER ON FRONT AND SIDES -CORONADO STONE "STRIP STONE", COLOR 'BLA<:;K FOREST'. @) 4" POUR-IN-PLACE CONCRETE COUNTERTOP, DAVIS INTECSoRAL COLOR, SMOOTH FINISH f,',fTH SEALER. #S REBAR@ 16" O.C. BOTH ~YS, I" OVERHANG, ALL AROUND. COLOR TO SE '<SRAPHITE' @ SSG UNIT -CSoRAND HALL "TURSO ELITE 5-SURNER BUILT-IN CSoAS CSoRILL". <:;UT OUT SIZE 98.5" V'l x l'l."15" DEEP x '1.5" HICSoH. AVAILABLE AT SARSEGUES CSoALORE, f,',V'il"l.SSGCSoALORE.COM. @ SC!" STAINLESS STEEL DOUBLE ACCESS DOOR TO MAT<:;H SSG UNIT G) POT SHELF @ OMIT @) FINISH SURFACE c;oNCRETE PATIO @ VINYL FENCE -SEE CONSTRUCTION PLAN @ COMPACTED SUB-CSoRADE @ FINISH CSoRADE NOTES, I. CONTRACTOR SHALL COORDINATE NATURAL CSoAS LINE AND NECESSARY PERMITS. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE TITLE b :r N . I DATE, 08/25/2016 LOCATION OF PLANTING REVIEWED BY: DRAl-"lN SY, EF/HH AREAS. -------5" VOID SECTION A-A NOTTO SCALE "AS BUil T" DATE ~~DSC4f:,<" ~'j;;,,o '<:_.,,~~ ,,,7~ / -~.;;sp., I SHSET I CITY OF CARLSBAD ~ & _../•?U~ :r r,~ ;u~ • l (.,./, ,~ DA /,* d'_;. 03).,1~, ~ "f~-------EXP. OA1': -<<#: OF Cl\1..1~0 rla 2681 ARD'~ .f' ,;, •• 'I .,. A S S O C I ATES,, " « ,, landscap 2442 secon san diego ca 921 e architecture d avenue 01 619 718 9660 DATE INITLI\L DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL PLANNING DIVISION s CONSTRUCTION DETAILS FOR: OUARRY CREEK PA R-3 MODELS APPROVED /-tr.;,, ( Gr-E:l\__,ir r-z--i.t<..o PLANNING DATE DWN BY: I PROJECT NO. I DRAWING NO. DATE INITIAL CHKD BY: CT 15-05 484-5U CrTY APPROVAL RVWD BY: ' . , -st- I II) 11'-0" I I FRONT ELEVATION ' • \ \ I -r--r-- 1 i I i I I I I I I I I I I I I I I I I I . I (D 6" C.MU )f,IALLS )f,IITH #9 REBAR VER.TIC.AL @ 16" O.C.. @ FINISH SURFACE C.ONC.RETE PATIO -CSR.OUT FILL ALL CELLS SOLID. @ C.ONC.RETE FOOTINCS )f,IITH #9 REBAR CONTINUOUS BOTH )f,IAYS @ 16" O.C.. @ STONE VENEER ALL SIDES -12" X 24" C.ORONADOSTONE "FRENCH LIMESTONE", COLOR 'COUNTRY BEICSE'. G) OUTDOOR TV. 42" SKYVUE OUTDOOR TV, NX6DS-5OO, BLACK )f,IITH JIiii-Fi AND SEC.URE PEDESTAL MOUNT. C.ONTR.AC.TOR SHALL COORDINATE JIIIITH SITE SUPERINTENDENT TO PROVIDE ELECTRIC.AL CONNECTION 4 ROUTER JIIIITH MODEM IN MODEL OR SALE OFFICE. @ ELECTRIC. FIREPLAC.E INSERT -AMANTII 60" BUILT-IN ELECTRIC. FIREPLAC.E (PANORAMA, BL-6O-DEEP) AV A I LAB LE, v.v.1"1 .modernb I aze .c.om INSTALL JIIIITH FINISHINCS TILE C.OVER.INCS METAL SURROUND 24"X6O"XI2" DEPTH @VINYL FENCE -SEE C.ONSTRUC.TION PLAN @c.OMPAC.TED SUB-CSR.ADE @ REMOVABLE 42" X 8" PANEL JIIIITH CORONADO STONE FINISH TO MATC.H @ BULLNOSE EDCSINCS TO MATC.H, CHAMFER C.ORNERS @!" STEEL PLATE LINTEL BRIDCSINCS OPENINCSS NOTE: I. C.ONTRAC.TOR SHALL C.OORDINATE NATURAL CSAS LINE AND NEC.ESSARY PERMITS. 2. ALL SIJRFAC.ES TO REC.EIVE (2) C.OATS CLEAR, MATTE FINISH SEALER. 9. C.ONTRAC.TOR TO PROVIDE OUTDOOR RATED ELECTRIC.AL OUTLETS BEHIND FIREPLAC.E INSERT AND AT BAC.K OF TV NIC.HE. 12" 8" d) _,.......-'-1-~~~---b ''•' ~ •, •. ' •-• .2 SEC.TIONA-A l'-8" 8" 12" ®i ~ I I I 1----r-~~-, I l l==l=,=~""""1 I I I l I I ! l ! I I I '<t" I l I I I I I ® 16" .,-,. I I 1-+~~-I '" I I 1 I e--¥ I I I i I SECTION 6-6 @ TV Nie.HE G) HEARTH /A~~F~ir~ep~l~ac_e_an_d_TV __ w_a_l_l --------------------------------------------------------~ ') NOT TO SCALE Al c.7 A__J C, .. PLAN VIEJIII l'-6" , la' 11 "'1 • -~ ~ • • • -~--1 1-· , 2 -, ~Ill '-= • · -~. 1--fl~ .1--.---~-:---~ I I l 2'-6" t 9 'I , SEAT/l'IALL SECTION C.-C. 0 @ ® 0 ® @ G) ® B B l J REINFORCED C.MU )f,IALL-PER STRUCTURAL ENCSINEER CONCRETE FOOTINCS-PER STRUCTURAL ENCSINEER REBAR-PER STRUC.TUR.AL ENCSINEER REBAR-PER STRUC.TURAL ENCSINEER P.I.P. C.ONC.RETE SEAT. C.OLOR TO BE DAVIS 'MOC.HA' - SMOOTH TROJIIIEL FINISH -RADIUS TOP AND BOTTOM 1/2" #9 REBAR @ 12" O.C.. BOTH )f,IAYS IN SEAT CSR.OUT FILL VOID CREATE BATTER. OUT OF CSR.OUT -PITCH TO MATC.H PILASTER CORONADO STONE VENEER, 10% ROC.KY MOUNTAIN LEDCSE, MEADO)f,I SPRINCSS STACKED 4 90% APPALAC.HIAN FIELDSTONE, MADISON COUNTY. @ DAL TILE VENEER TO BE AYERS ROC.K AYOS RUSTIC. REMNAN 9 9 ILE A ILA d T X T VA BEL, 1"11"11"1. altile.c.om, JIIIITH ' C.BP #106 'EARTH CSR.OUT' ® 12" JIIIIDE 2.29"HT CORONADO STONE CHISELED STONE /l'IALL CAP -'BROJIIINSTONE' @ 4" DIA. PERF DRAIN LINE IN 12" DIA. CSRAVEL-JIIIRAP IN FILTER FABRIC. AND C.ONNEC.T TO AREA DRAIN SYSTEM ® FINISH SURFACE OF PAVINCS ,--" Low Wall with Accent Pot & Bench ""B ... r---------7 I I L, rJ I I I • • lrr----11-=ll+--.t15 I I, • A· .;,. . ., . 16 11 l 24' 'I l 'I )f,IALL SECTION A-A PILASTER. SECTION B-B ® 12" SQ. CMIJ COLUMN BLOC.K -CORONADO STONE VENEER, 10% ROCKY MOUNTAIN LEDCSE, MEADOJIII SPRINCSS STACKED 4 90% APPALACHIAN FIELDSTONE, MADISON COUNTY. CSR.OUT FILL ALL CELLS SOLID. CREATE BATTER JIIIITH CSR.OUT. @ 16" SQUARE CORONADO STONE CHISELED STONE POST C.AP - 'BRO/l'INSTONE' 'Is\ 6"x8"xl6" C.MU BLOC.K /l'IALL -CSR.OUT FILL ALL CELLS \!.:::) SOLID-STUCCO FINISH TO MATCH ARC.HITEC.TURE @ #9 REBAR RINCS HORIZONTAL @ 24" O.C.. @#9 REBAR VERT @ ALL 4 CORNERS @) #9 REBAR C.ONT. IN FOOTINCS AND HORIZONTAL@ 16" 0.C.. ® #9 REBAR VERT.@ 16" ON CENTER -CSR.OUT CELLS )f,IITH REBAR @ FINISH CSR.ADE @ C.OMPAC. TED SUB-CSR.ADE £ l)!IQSG,4,o<" ~ """'" '"' 'b :Ja o/-ri .:fl:%\ ~--:: 0 , -. ;-,.-.,. ~~•;"~ F>, Ir , NOT TO ! ,... 'Jtf., 'ii1f) '\) "'1,i:---El<P. DATE <#: ~'OF Cf'-\. ,~o rla 268 J ··> ,J HOWARD < '1 4, ,: •!1- ''! i~ ~~· ASSOCIATES ❖ .•, -landscape architecture 2442 second avenue san di ego ca 92 IOI 619 718 9660 APPROVED FOR PLANTING AND IRRIGATION ONLY, "AS BUil T" INCLUDING PRECISE TITLE DATE DAT!:, 08/25/2016 LOCATION OF PLANTING REVIEWED BY: DRAll'IN ElY, EP/HH AREAS. I SH6ET I CITY OF CARLSBAD W£J PLANNING DIVISION s CONSTRUCTION DETAILS FOR: OUARRY CREEK PA R-3 MODELS APPROVED ~', q: t\l_At-1-z.-,.,..., PLANNING DATE DWN BY: PROJECT NO. DRAWING NO. DATE INrTIAL DATE INITTAL DATE INITIAL CHKD BY: ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: CT 15-05 484-5U :2' TYP. TRELLIS SIDE El EVATIQN 4 FACING-SALES OFFICE 9 ,... 0 0 . . 2 TRELLIS SECTION 9 4 CD 6X8 BEAM @ 4X6 JOISTS ® 6X6 POSTS 0 4X6 SUPPORTS ® 2X2 PLANT-ONS, 4 SIDES ® FINISH GRADE G) SIMPSON CB66 COLUMN BASE ® SIMPSON C..C..66 COLUMN C..AP G) CHAMFER ALL BEAM, JOISTS $ RAFTER ENDS 45 DEGREES, I" (TYP.) ' I' = \) I N ' ,, = ,D _, N 9 10 --- ' ~ I . ~ --- ------ 0) v- / / ' ~ f • , I's'J .v - -----~ PLAN YIEl'i IRE! I 15 ELEVATION f?) 2 CD 6X6 POST. ROUT TO ACCOMMODATE HARDY'IARE ,-;\ 4X8 DF BEAM -BOLT THROUGH -BEAM \:::,J ENDS TO MATCH JOIST ENDS ® 4X6 DF RAFTER @ 12" O.C. 0 SIMPSON CB66 COLUMN BASE ® 12" CMU BLOCK GROUT FILL ALL CELLS ® #9 REBAR VERTICAL G) FINISH -CORONADO STONE 10% ROCKY MOUNTAIN LEDGE, MEADOY'l SPRINGS STACKED$ 90% APPALACHIAN FIELDSTONE, MADISON COUNTY ® 20" 5G. CORONADO STONE FLAGSTONE STONE POST CAP 'BROV'lNSTONE'. 2" REVEAL G) CONCRETE FOOTING @ CHAMFER ALL BEAM, JOIST$ RAFTER ENDS 45 DEGREES, I" TYP. I I • l :24 " l 'I ., e 6 11 TT"'P. 1~A~ ..... P_a_rk_i_ngllllllll..A_re_a_O_v_e_rh_e_a_d_T_r_e_lli_s __________________________ ~~~ ~ ~ NITTro-~ PILASTER SECTION ~B~ ... _O_v_e_rh_e_a_d_T_r_e_llis ______________________ ~~~ ~ ~ NOT TO SCALE vJ::IDSC,\o tf $. ;;;:.,o 'la <" ~ "o/.·. ) "<l,,:;:r 0 ~ ~ ~ {fj _.,, Qy'!)\/~ '? ( \GN.;-~E • If~ - u>,} .,g1'0, ; '<"* ~EXP.DATE rf.' OF CA\. l~O rla 2681 HOWA RD'~ .,,, < ASSOC ., landscape 2442 second san diego ca 9210 I ATES" architecture avenue I 619 718 9660 DATE INTTl<\L ENGINEER OF WORK APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE DATE, 08/25/2016 LOCATION OF PLANTING DR.Av-IN ElY, EP/HH AREAS. DATE INITl<\L DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL CrTY APPROVAL "AS BUil T" TITLE DATE REVIEWED BY: I SH7ET I CITY OF CARLSBAD WJJ PLANNING DIVISION s CONSTRUCTION DETAILS FOR: OUARRY CR££K PA R-3 MODELS APPROVED ~ Gt:~\-'\\-1-Z-"i-k., PLANNING DATE DWN BY: I PROJECT NO. I !a4~su· CHKD BY: CT 15-05 RVWD BY: I ' ' I I ! I I -----~ .. ---------~ rla 2681 :;HOWARD:~:; ·~"'ASSOCIATES, .,. ~ ,;. ,, landscape architecture 2442 second avenue san diego ca 92101 619 718 9660 DATE, 08/25/2016 DRAl-"IN BY, EP/HH LOT 12 KEY MAP NOTES, I. LOCATE ALL SPRAY HEADS MIN. 24" FROM IMPERMEABLE PAVED 5URFAC.E5. 2. IRRIGATION VALVES AND MAINLINE LOCATIONS ARE 5HO~ SCHEMATIC.ALLY. ALL MAINLINE AND VALVES SHALL BE LOCATED OUTSIDE OF THE STREET R.O.Y'I. 9. SEE PRODUCTION LANDSCAPE FLANS, C.ITY OF CARLSBAD DJAIG II 484-SR FOR F.O.C.., RECLAIMED JAIATER METER, MASTER VALVE AND FLOY'! SENSOR, LOCATED ON EL SAL TO FALLS STREET AT PROJECT SIDE ENTRY 4. IRRIGATION 5HOY'IN SCREENED 15 FER PRODUCTION LANDSCAPE FLANS, C.ITY OF CARLSBAD DJAIG II 484-SR TEMPORARY IRRIGATION NOTE, DRIP TUBING INSIDE PRIVATE COURTYARDS TO BE TEMFORARIL Y C.ONNEC.TED TO TEMPORARY VALVE A-9. AT MODEL C.L05E, IRRIGATION INSIDE EAC.H YARD Y'IILL BE SEPARATED AND EAC.H YARD JAIILL RECEIVE XAC.Z-015-FRF CONTROL ZONE KIT C.ONNEC.TED AT POTABLE HOUSE HOSE BIB RISER IN COURTYARD, A RAINBIRD E5F-LXME 4 STATION SMART CONTROLLER JAIITH ETM-RGX RAIN GAUGE FOUNTAIN AUTO FILL VALVE A-6 SHALL BE RELOCATED TO MODEL FLANS. POTTERY IRRIGATION NOTE: SEE POTTING NOTES, SHEET 14 FOR AUTOMATIC. IRRl6ATION TO POTTED PLANTS ON PATIOS. C.ONTRAC.TOR SHALL COORDINATE JAIITH SITE SUPERINTENDENT TO PROVIDE ALL NEC.ESSARY SLEEVES FOR IRRl6ATION. APPROVED FOR PLANTING North AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. 0 5' 1 O' r t j Scale 1" = 10' "AS BU I LT" TITLE REVIEWED BY: NTS 30' DATE ~ CITY OF CARLSBAD ns7 1------11----+-------------------lf---+---l---+----1 lJL_J PLANNING DIVISION ~ 1------1f---t-------------------lf---+---J---+----I DATE INrTIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL IRRIGATION PLAN FOR: OUARRY CREEK PA R-3 MODELS APPROVED PLANNING DWN BY: __ _ CHKD BY: __ _ RVWD BY: PROJECT NO. CT 15-05 IZ-7-ll,., DATE DRAWING NO. 484-5U ® 1 1 10 9 NOTE: 0 ROUND PURPLE PLASTIC VAf.VE ® BOX, AMATEK OR EQUAL FINISH GRADE 0 BALL VALVE © INTEGRAL UNIONS © PVC SCH. 40, 45' ELL (TYP) © PVC PRESSURE MAINUNE PIPE (SEE SPECS.) 0 1 CU. FT. PEA GRAVEL © 2X4 REOWOOD OR BRICK BLOCKING ® DEPTH-SEE SPECIFlCATIONS G) FINISH GRADE/TOP OF MULCH @ QUICK-COUPUNG VALVE WITH LOCKING PURPLE CAP @ VALVE BOX WITH PURPLE COVER: 6-INCH SIZE © 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL © PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) © BRICK (1 OF 2) 0 PVC SCH 40 STREET ELL © PVC SCH 40 TEE OR ELL ® PVC MAINLINE PIPE @ PVC SCH 40 ELL @2• x 2" REDWOOD STAKE W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT SUPPORT SYSTEM I, FURNISH F/TilNGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. 2. QUICK COUPLER VALVES SHALL BE OF A TYPE APPROVED FOR RECYCLED WATER USE. QUICK-COUPLING VALVE {D 4-INCH e>RATE (INCLUDED) @ BUSSLER, RAIN SIRD 1402 0.50 <S>PM (INCLUDED) @ ROOT Y'IATERINe SYSTEM: RAIN BIRO Ri'IS-S<S02 (INCLUDES 1402 O.SO <&PM BU66LER Y<ITH RISER, 61'<.ATE, SY<ING ASSEHBLY, 1/2' MALE NFT INLET, AND BASKET CANISTER) @ FINISH <SRADE @ OPTIONAL PEA <SRAVEL OR RJIIIS SAND SOCK ('RY<S-SOCK) FOR SANPY SOILS @ 1/2-INCH PVC SCH e,o NIPPLE (INCLUDED) (Z) I/2-INCH 'lO-DE<S>REE EI.ElOJ.'< (INCLUDED) @ I2-INCH SY<INe ASSEMBLY (INCLUDED) @ I/2-INCH MALE NFT INLET (INCLUDED) @ PVC SCH 40 TEE OR EL G) LATERAL PIPE @ 4-INCH BASKET 11\'EAVE CANISTER E ROOT WATERING SYSTEM • • • • . --9 IC 5 11 ◄---(112 frOUTSIDE WALL_) 1 0 HYBRID CONTROLLER: RAIN BIRD ESP SERIES OUTDOOR WALL MOUNT 1.5-INCH PVC SCH 40 CONDUIT AND FITTINGS 0 WIRES TO REMOTE CONTROL VALVES 0 JUNCTION BOX ® 1-INCH PVC SCH 40 CONDUIT TO POWER SUPPLY B CONTROLLER D PEB VALVE G) 30-INCH LINEAR LENGTH OF WIRE, COILED @ WATER PROOF CONNECTION (I OF 2) @10 TAG © REMOTE CONTROL VAf.VE: RAIN BIRD PEB © VALVE BOX WITH COVER: 12-INCH SIZE © FINISH GRADE/TOP OF MULCH 0 PVC SCH 80 NIPPLE (CLOSE) @ PVC SCH 40 ELL ® PVC SCH 80 NIPPLE (LENGTH AS REQUIREO) @BRICK (1 OF 4) @PVC MAINLINE PIPE @scH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND SCH 40 ELL @ PVC SCH 40 TEE OR ELL (8) PVC SCH 40 MALE ADAPTER @) PVC LATERAL PIPE @) 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL --------F1NISH GRADE --------PVC SCH 40 ELL -------PVC SCH 80 NIPPLE (LENGTH /JS REQUIRED, 1 OF 2) ------30-INCH LINEAR LENGTH OF WIRE, COILED -----WATERPROOF CONNECTION: RAIN BIRD SPLICE-1 (1 OF 2) 10 TAG: RAIN BIRD VID SERIES VALVE 80)( WITH COVER: RAIN BIRD VB-STD LATERAL PIPE BRICK (1 OF 4) 3-INCH MINIMUM DEPTH OF 3/.+-INCH WASHED GRAVEL PVC SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND PVC SCH .+O ELL '----CONTROL ZONE KIT: RAIN BIRO XCZ-075-PRF-BF (INCLUDES OV-100 VALVE, PVC SCH 40 TEE OR ELL BACK FLUSH PRESSURE REGULATING FILTER, DUCK BILL BOOT) PVC MAINLINE F XCZ-075-PRF CONTROL ZONE KIT 21-~-.11 CD RAIN BIRD tT MANAGER TIPPING RAIN GAUGE: RAIN BIRD ETM-RG (DIMENSIONS JIX," H X 119(,• W X 3',i;" D} ® RAIN BIRD ESP-LX MODULAR CONTROLLER WrrH ET MANAGER CARTRIDGE @ 1-INCH PVC SCH 40 CONDUIT AND FITTINGS 0 ® @ 1 Ji-INCH PVC SCH 40 CONDUIT MIO flTTINGS 1-INCH PVC SCH 40 CONDUIT TO POWER SUPPLY CONNECT TIPPING RAIN GAUGE TO Er MAW.GER CARTRIDGE: 0 30' LENGTH OF WIRE TO TIPPING RAIN GAUGE (INCLUDED}. CUT TO REQUIRED LENGTH. IF ADDITIONAL DISTANCE IS REQUIRED THE RAIN GAUGE CAN HAVE A MAXIMUM CABL£ RUN OF' 500'. USE 1B AWG PS A MINIMUM WIRE SIZE FOR AODmONA.L CABLE. @ MOUNTING SCREWS (NOT' /NCWOED} @ MOUNTING PLATE WITH 2 MOUNTING HOLES @ WIRE NOTCH @ RAIN DRAINAGE HOLES @ LEVEL SURFACE OR BRACKET TIPPING RAIN GAUGE WITH ET MANAGER CARTRIDGE IRRIGATION NOTES I. THE IRRl<S>ATION PLAN IS DIA<S>RAMMATIC. ALL IRRIGATION EGUIPMENT SHALL BE LOCATED IN PLANTIN<S> AREA5 ONLY, UNLESS NOTED OTHERY<ISE. REFER TO THE IRRIGATION U:<SEND AND DETAILS FOR EGUIPMENT AND INSTALLATION. 2. CONTRAC.TOR SHALL KEEP THE PREMISES CLEAN AND FREE OF EXCESS EQUIPMENT, MATERIALS, AND RUBBISH INCIDENTAL TO Y<ORK OF THIS SECTION. S. A. ALL RISERS SHALL BE P.V.C. SCHEDULE f>O. B. ALL PIPE FITTIN<S>S SHALL SE P.VC. SCHEDULE 40. 4. A. ALL J/IIIRE SHALL SE 14 <S>Al.16E AY<e (MAX. eAUeEJ J.'<ITH SHEATH, MAXI-JIIIIRE BY PAleE EU:CTRIC. DIRECT SIJRIAL TYf'E, AND ALL SPLICES AND CONNECTIONS SHALL BE MADE Y<ITH SM GELPACK DBY CONNECTORS. 6. EACH CONNECTION FROM DECODER TO VALVE SHALL MAINTAIN THE SAME J.'<IRE COLOR AS DECODER. C. ALL Y<IRES SHALL SE INSTALLED J.'<ITH TJ/110 (2) FEET OF EXCESS J.'<IRE (COILED) AT THE END OF cACH J.'<IRE RUN. D. CONTROL J.'<IRE SHALL BE BUNDLED AND PLACED BENEATH MAINLINE. E. VALVE SHALL BE A MAXIMUM IS' FROM DECODER F. CONTROL J/IIIRE SHALL FOLLOJ/11 MAINLINE. e. LOOP J/IIIRE BACK TO CONTROLU:R IF CONTROLLER J.'<IRE RUN IS LONGER THAN 2.4 MILES. H. CONTROL J.'<IRES (I.E. MAXI-J/IIIRES) MUST MAINTAIN A I0-FOOT SEPARATION FROM ELECTRICAL TRANSFORMERS $ UNDER<S>ROUND Hl<S>H VOL TA<S>E POJ/IIER LINES. 5. 6ACKFLOJ.'< PREVENTION DEVICES SHALL 6E LOCATED AS INDICATED ON THE IRRIGATION PLAN. INSTALLATION SHALL CONFORM TO LOCAL <S>OVERNINcS-CODES AND REcS-ULATIONS AND MANUFACTURER'S SPECIFICATIONS. CMJ/IID BAC,KFLOJ.'< SPECIALIST TO APPROVE LOCATION ph. (ie,o) 4Se-21.2.2 x1I52 6. CHECK VALVES SHALL BE USED Y<HERE INPICATED AND Y<HERE NECESSARY TO PREVENT J/IIATER FLOY< FROM LOJIIIER ELEVATION HEADS Y<HEN SYSTEM IS TURNED OFF. 1. ALL PRESSURE MAINLINES SHALL HAVE A Je," MINIMUM COVER FOR .2-1/2" MAINLINE AND LESS AND .24" COVER FOR S"-5-I/:2" SIZE MAINLINE. ALL LATERALS SHALL HAVE A MINMUM TJ/IIELVE (12) INCHES OF COVER. TRENCH BACKFILL SHALL SE FREE OF ANY MATERIAL THAT MAY DAMAeE IAAlcS-ATION PIPE OR EGUIPMENT. IN THE EVENT OF BACKFILL SETTLEMENT, CONTRAC.TOR SHALL PERFORM REQUIRED REPAIRS AT HIS OJ.'<N C,OST. e. ALL AUTOMATIC, VALVES SHALL BE LOCATED J.'<ITHIN SHRUe AREAS. IN BOXES SHALL BE INSTALLED IN PURPLE VALVE BOXES, ONE VALVE PER BOX, J.'<ITH FOUR (4) INCHES OF PEA <S>RAVEL BENEATH EACH VALVE. BALL VALVES SHALL BE LOCATED IN SEPARATE VALVE OOXE5. 'l. SEE SLEEVE NOTES SELOJ.'<. 10. AUTOMATIC CONTROLLERS SHALL BE SIZE AND TYPE AS NAMED, AND INSTALLED Y<HERE INDICATED ON IRRl<S>ATION PLAN. CONTROL J.'<IRES SHALL BE SLEEVED UNDER PAVIN<S> IN I" DIAMETER ELECTRICAL CONPUIT. I CONTROL J/IIIRE MAX. PER SLEEVE. A. 120 VOLT SERVICE TO CONTROLLER SHALL SE PROVIDED BY THE OJ.'<NER II. PRIOR TO BACKFILLING IRRlcS-ATION TRENCHES, A. ALL MAINLINES IN THE SYSTEM SHALL BE CAPPED ANP PRESSURE TESTED AT 1:25 P.S.I. FOR A PERIOD OF FOUR HOURS. ANY LEAKS FOUND SHALL SE CORRECTED BY REMOVIN<S> THE LEAKIN<S> PIPE OR FITTIN<S>S AND INSTALLIN<S> NEJ/11 MATERIAL IN ITS PLACE. B. ALL LATERALS SHALL BE PRESSURE TESTED AT DESl<S>N PRESSURE FOR ONE HOUR. C,, THE CONTRACTOR SHALL NOT ALLOY< NOR CAUSE ANY OF HIS Y<ORK TO SE COVERED UNTIL IT HAS BEEN INSPECTED, TESTED AND APPROVED BY THE Oi'<NER'S AUTHORIZED REPRESENTATIVE AND CITY INSPECTOR. 12. IRRlcS-ATION CONTRAC.TOR SHALL ADJUST ALL HEADS TO PROVIDE EVEN C,OVERAeE AND TO KEEP SPRAY OFF BUILDIN<S>S, Y<ALKJ/IIAYS, Y<AL.LS, AND DRIVES. IS. Y<HEN THE SPRINKLER SYSTEM IS COMPLETED, THE CONTRAC.TOR, IN THE PRESENCE OF THE OJ.'<NER'S AUTHORIZED REPRESENTATIVE, SHALL PERFORM A COVERAcS-E TEST OF J/IIATER AFFORDED THE PLANTINcS-AREA5 TO ENSURE IT IS COMPLETE AND ADEGUATE. CITY INSPECTOR TO APPROVE COVERA<S>E. THE CONTRAC.TOR SHALL FURNISH ALL MATERIALS AND PERFORM ALL J/IIORK REGUIRED TO CORRECT ANY INADEGUACIES OF COVERAeE AT HIS OJ.'<N COST. IRRl<S>ATION CONTRACTOR SHALL MAINTAIN THE SYSTEM FOR A PERIOD OF SIXTY (60) DAYS AND SHALL J/IIATER ON A DAILY 6ASIS. 14. PRIOR TO FINAL ACCEPTANCE, THE CONTRAC.TOR SHALL FURNISH A COMPLETE 'AS-BUILT' DRAJ.'<INe TO THE LANDSCAPE ARCHITECT FOR COMPLETION OF PLAN DRAJ/IIIN65 AND THREE PRINTS TO THE OJIIINER SHOY<ING EXACT LOCATIONS OF AL.L ITEMS INSTALLED. IS. PRIOR TO FINAL ACCEPTANCE, THE IRRl<S>ATION CONTRACTOR SHALL. PLACE A LAMINATED, REDUCED COPY OF THE AS-BUILT IRRl<S>ATION PLAN, COLOR-CODED AS TO COVERA<S>E AREAS FOR EACH VALVE, IN THE CONTROLLER ENCLOSURE. 16. THE IRRlcS-ATION CONTRACTOR SHALL euARANTEE THE ENTIRE IRRl<S>ATION SYSTEM TO BE FREE OF DEFECTS IN Y<ORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (I) YEAR FROM FINAL ACCEPTANCE BY THE OY<NER. 11. "THRUST BLOCKS CONSISTINcS-OF A MINIMUM OF I CUBIC, FOOT OF CONCRETE (.2POO PSI) SHALL BE INSTALU:D AROUND MAINLINES S " AND ABOVE AT ELOOJ.'<S AND AT POINTS OF CHANe.E IN DIRECTION." (CITY OF CARLSBAD LANDSCAPE MANUAL IV.S-5). le. INSTALL POP-UPS Y<ITHIN 10 FEET OF ALL PEDESTRIAN USES. l'l. ALL IRRl<S>ATION EGUIPMENT UTILIZINe RECLAIMED J/IIATER SHALL BE COLORED PURPLE PER CARLSBAD MUNICIPAL J/IIATER DISTRICT REGUIREMENTS. 20. USE PME ELECTRIC, MAXICOM J.'<IRE FOR :2-Y<IRE DECODER J.'<IRE PATH. 21. J/IIARNIN6 TAPES REGUIRED (.2) ONE TO SE LOCATED DIRECTLY ON TOP OF MAINLINE AND ONE 12" ABOVE. 22. SUF<.5E PROTECTOR AND cS-ROUNDINcS-ROD IS NEEDED EVERY 450' OF L.INEAR OF CONTROL. J/IIIRE. SEE RAINBIRD SPECIFICATIONS FOR cS-ROUNDING INSTRUCTIONS. 26. FINA,l.. AS-BUILT PLANS SHALL BE DRAFTED CLEARLY TO THE SATISFACTION OF THE CITY, AND THE FINAL PLANS SHALL BE SUBMITTED TO THE CITY FOR THEIR KEEPINe. 24. FINAL AS-BUILT PLANS J/IIILL BE REGUIRED TO BE REVIEfi'IED AND APPROVED BE THE CITY AND FINAL PLANS Y<ILL BE REGUIRED TO BE APPROVED ANP Sle>NED BY THE CITY PRIOR TO RELEASE OF SECURITIES. NOTE: NE~ IRRIGATION MAINLINE AND VALVES SHALL BE HIGH-LINED AND C.ONNEC.TED TO A POTABLE ~ATER SOURC.E FENDING SUC.C.ESSFUL C.OMPLETETION OF GROSS C.ONNEC.TION TESTS AS PREFORMED BY THE C.M~D AND DEH. FINAL C.ONNEC.TION TO REC.Ye.LED Y'!ATER SHALL BE PREFORMED ONLY AFTER APPROVAL 15 PROVIDED. 12" MIN REQ. VERT. SEPARATION ~--------a,@ LEGEND G) STREET SURFACE @POTABLE SERVICE LINE @RECLAIMED WATER IRRIGA170N MAINUNE W/ SLEEVE NOTES: Af.L RECLAIMED WATER IRRIGA170N PIPE AND SLEEVES SHALL BE PURPLE AND LABELED AS SPECIFIED IN: "STANDARD SPECIFlCATIONS FOR PRIVATE IRRIGATION SYSTEMS" AND "CARLSBAD RECLAMATION RULES AND REGULATIONS FOR CONSTRUC170N OF RECLAIMEO WATER MAINS' OCTOBER 1993 HOW ~~sca.,:,~ " ~· ~~ -n\ ¥ . .. ..)(j~~~'l!J\-., . If ~ DA1E "): .,.,,,11~1 '<'° -f~ EXP. DAlE ,<#; OF Cl>.'-I ~a rla 2681 ARD:~ POTABLE MAINLINE CROSSING ,,,,ASSOC I ATES,, ", ,,. , landscap 2442 secon san diego ca 921 e architecture d avenue 01 619 718 9660 DATE SYMBOL MAN'FR MODEL Irrigation Legend DESCRIPTION GPM RADIUS PSI DETAIL E9 RAINBIRD @ RAINBIRD ~ RAINBIRD [Q] NETAFIM II] NETAFIM 1§) HUNTER ....... NIBCO-SCOTT @ HUNTER XACZ-015-PRF XCZ-015-PRF FEB SERIES LOV'I FLOV'I ANTI-SIPHON CONTROL ZONE KIT CONTROL ZONE KIT REMOTE CONTROL VALVE (SIZE PER PLAN) AIR RELIEF VALVE -NOT 5HOV'IN -LOCATE ONE AT HIGH POINT OF EACH SUPPLY OR EXHAUST HEADER FLUSH VALVE -NOT SHOV'IN -LOCATE ONE IN EACH EXHAUST HEAPER RZJl'lS-96-25-CV-R BUBBLER ASSEMBLY -2 BUBBLER.5 PER TREE .25 SHTIO-K SHT"'I-F 5HT"'I-D SHTIO-H SHTIO-F 90 SHT"'I-E TRU-UNION HG!-44LRC-AV'I-R PLASTIC BALL VALVE IN BOX (LINE SIZE) SHT"'I-A RECYCLED G!UICK COUPLING VALVE -I" SIZE -ACME THREADS SHT"'I-C AND LOCKING COVER -~---a NET AFIM ------------------------ 'TECHLINE RV'!' -TLRY'l4-Ie,I0 DRIP 11JBING SYSTEM-0.4 GPH EMISSION POINTS @ Ie," SPACING -2"-9" OF COVER 5HTIO-C-H -----PVC SCH 40 'ALERTLINE' RECYCLED MAINLINE-I" MIN. SIZE ---PVC CL 200 'ALERTLINE:' RECYCLED LATERAL LINE-SIZE PER PLAN -9/4" MINIMUM SIZE SHT"'I-H 4 SHTIO-A/S SHT"'I-H 4 SHTIO-A/S SHT"'I-H 4 SHTIO-A/S SHT"'I-H 4 SHTIO-A/S -----PVC SCH 40 TEMPORARY RECYCLED MAINLINE-I' MIN. SIZE _.,_ .. _.,_.,_ .. _ PVC CL 200 POTABLE LATERAL LINE-SIZE PER PLAN -9/4" MINIMUM SIZE =====PVC SCH 40 SLEEVE -TV'IICE LINE SIZE SHTIO-A/S @ RAINBIR.D ESP-W<MEF e, STATION SMART CONTROLLER IN PLASTIC, LOCKING l'IALL-MOUNT EXTERIOR CASE SHT"'I-B Y'llTH ETC-LX -ET MANAGER. VilTH ETM-RMK-REMOTE ANTENNA FOR SETTER SIGNAL ffi VALVE KEY --'-A'-1---=-~--1>----A = GPM 6 = VAL VE SEG!UENCE NUMBER C = VALVE SIZE INITIAL SEE SHEET 10 FOR ADDITIONAL IRRIGATION DETAILS SEE SHEET 11-12 FOR IRRIGATION SPEC.S SLEEVE NOTE: SLEEVES UNDER PAVING (NON-ROADS), LESS THAN B" IN DIAMETER-IE>" GOVER B" TO 5-1/2" IN DIAMETER-24" GOVER 6" OR GREATER IN DIAMETER-:36" GOVER SC.HEDULE 40 PVC. NOTE: POPUPS ARE REQUIRED IN RIGHT-OF-V'-IAY AND SHRUB BEDS ~ITHIN 10' OF HARDSC.APE AND ALL OTHER AREAS V'-IHERE PEDESTRIAN TRAFFIC. MAY OC.C.UR. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE DATE, 08/25/2016 LOCATION OF PLANTING DRAV'IN BY, EP/HH AREAS. DATE INITIAf. DATE INITIAf. 15 ore 0 Oi2 2.0 O.Oil {t016 E Cl2DO 314' .2 5 0_1p O 030 f -,a:wo 31'4" 30 0.2-0 0-040 G <:,_= 214~ 35 025 0015 H a,oo 314'· 40 0.30 0,021 l a.,uo Jl4' •S 040 0 00{) J Cl 200 314·• .,, 0.47 0'.07t " u:roo 3/4" 6.0 e,"6-0 0078 ' ". -. -. ----·--··--------~--'----'---'-----'----'---'----' ' I ' I • f,,,.·_,ToTALLAlERAL.·sYs'Te.11 Loss: ---i · --: - 1----------:-,-·--------------____ ; ___ ,--·-' ------__ J --• --_. -____ J __ . _______ _ I Pipe , PiP'l , Length ! : Se~ott , 1 'Nbln Ll'l'l• l Se.:tlon,: 1'ypit I Size : 1100 I GPM ! PSI LOJS j .PSf-Los. : --I A I SGH40111171 , 25 I 15 I b.2 I 00,0 I 1~_"!_C!f!-L_!AAl~L!NE_SY~!EML0SS -i ___ _ -i--: _ i O.!l!SO, -------·--·-------i•• _____ ; ___ ,I _____ ) __ --·1 I ! , ---r--Qtf: "!PS1 i.O~-)ic:rfai l-a!i&-! , Wa::.er la-terat I 1 o iJ oo: o_oo li'VaterMeter I 1 030 03fl: IMmt-~Control Val\e I 0_60' 1 '1,00. ' 1 00 Flow Sensor '00 Control Vallie ' Z.90,· ,Head Lass I G.am in-S)lstem loss 235 0433. iE. FITTING lOSSeS 1fi% TOTAL LOSS} 2$5 f'.. MIN REQ P~ES.SURE AVAJL Bu: AH--IEA.D 4C 00 ,G_ DESlGN PRESSURE (D+E+F) : ', ! ' 61Jn H-t PRESSURE A.VAIl.Ae.t,E: A"fMEfER ' : • 125001 11-RES!OijAL PRESSURE iH-G) ' T .PSff 63.17 "AS BUil T" TITLE DATE REVIEWED BY: : PLANNING DIVI I : SHEETS WI CITY OF C~ct8BAD IGJJJ IRRIGATION NOTES, DETAILS AND LEGEND FOR: QUARRY CREEK PA R-3 MODELS I APPROVED ~~f=;l\~ I IZ-~-<~ DATE PLANNING DWN BY: PROJECT NO. CHKD BY: ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: I CT 15-05 I DRAWING NO. 484-5U MAINLINE, LATERAL. AND WIRING IN THE SAME TRENCH ' ' PLAN Vlfc/1 RUN WIRING BENEATH AND BESIDE MAINLINE. TAPE AND BUNDLE AT 10-FOOT INTERVALS. NOTES; SECTION VIEW MAINLINE LATERAL WIRING IN CONDUIT PIPE PIPE ALL SOLVENT WELD PLASTIC PIPING TO BE SNAKED IN TRENCH AS SHOWN. WIRE W/0 CONDUIT TIE A 24-INCH LOOP IN ALL WIRING AT CHANGES OF DIRECTION OF 30-0R GREATER. UNTIE AFTER ALL CONNECTIONS HAVE BEEN MADE. 1. SLEEVE BELOW ALL HARDSCAPE ELEMENTS WITH SCHEDULE 80 PVC TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. 2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS. A PIPE & WIRE TRENCHING FINl5>1 6,....,,1!-_j TeehJ~ reo 2-~Y' Tec.hllne 11.JSI . . S/4" 5GH 60 PVC NIPPLE-- PVC T1eE (5x5'<Tn· PVCPIPI ... . . . . FINISH GRADE AIR/VACUUM - RELIEF VALVE 6" ROUND VALVE BOX 1 /2" PVC COUPLING --- (TxT) 1 /2" SCH 80 RISER _.-- (LENGTH AS REQUIRED) BRICK SUPPORTS {TI,REE) 3/4" GRAVEL SUMP (1 CUBIC FOOT) J PVC PIPING AND FITTINGS .. .. . TECHLINE AIR RELIEF -'k----+--,-, I I I I I I I I II © :r-!•--1--4 G) RECLAIMED WATER SIGN @ FINISH GRADE 0 6' X 1-1/4" T POST © VANDAL PROOF HARDWARE RECYCLED SIGNAGE 12' .. ANTI • "! ·,·" ~ Y. ~ ~ ~~)0 NOTES; • MIN. CLEARA~~E. ,...--0 ·-. . ' 2 5 ,, ~ (j) PAVING @ □ITCH 0 SLEEVES © PVC CAP (TYPICAL) 1. ALL PVC IRRIGATION SLEEVES TO BE SCHEDULE 40/80 AS PER SLEEVING CHART PIPE. 2. ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT. 3. WHERE TI,ERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE TO 24-INCHES MINIMUM ABOVE FINISH GRADE. 4. MECHANICALLY TAMP TO 95,: PROCTOR. 5, WARNING TAPE PER PIPE AND TRENCHING DETAIL C, FINISH 6RAC>E 1----see PLAN!> l'"OR DIHEN5I0N (1":+~---Toa-hllno GY TUBIN6 \........J-----e,""-"Fll.l.EP TRENG>I (l=REE OF DEl>l<l5) TECHLINE TRENCHING I ( ) ( :') ii I J ~ FINISH GRADE 4 11 MIN., 6 11 MAX. I ' 1 SEE PL.ANS FOR T6chllne GV LATER.AL _ 5PAGI~ ~--------~-~-o,=e~RADE FIL TE"-AND F'RV ::-• B SLEEVING NTS D TECHLINE SUBGRADE INSTALLATION ----Techline® CV LATERAL ( OR EXHAUST HEADER) ~---VALVE BOX (INSTALL PER SPEC.SJ 9/4" GRAVEL SUMP (I CUBIC, FOOT) METER BOX ANP METER-- SIDEJ/'IALK;rt, CURS------....; I r--1 A~X.e" t ,_I .. ---24"---i POTABLE SERVIC.E LINE---11 12' Ml IMUM t 10' MINIMUM TO POTABLE MAINLINE IN STREET NOTE, VERTIC.AL C.L.1:ARANC,E OF 12" MINIMUM IS MANPATORY J/'IHEN CROSSINIS PATH OF A POTABLE J/'IATER LINE. INSTALLATION OF RE:c.YGU:D J/'IATER IRRIGATION MAINLINE 24" FROM FACE OF SIDEJl'IALK J/'IILL PROVIDE THE NEC.ESSARY 10' HORIZONTAL C.LEARANC.E FROM POTABLE MAINLINE IN STREET. SIPHON POTABLE SERVICE LINE CROSSING 0 30-INCH LINEAR LENGTH OF WIRE, COILED ® WATERPROOF CONNECTION: h'I RAIN BIRD DB SERIES (1 OF 2) \.VID TAG 0 LOW FLOW ANTI-SIPHON VALVE: RAIN BIRD ASV-LF-075 VALVE ,21 (INCLUDED IN XACZ-075-PRF KIT) \.V PRESSURE REGULATING FILTER: RAIN BIRD PRF-075-RBY ® (INCLUDED IN XACZ-075-PRF KIT) PVC SCH 80 UNION 0 PVC SCH 40 MALE ADAPTER ® UV RADIATION RESISTANT PVC SCH 40 PIPE (1 OF 2) ® FINISH GRADE/TOP OF MULCH @PVC SCH 40 ELL (1 OF 2) (j]) PVC LATERAL PIPE (1 OF 2) LOW FLOW CONTROL ZONE KIT 0 i;;;:: I ' I " I I I I I I ' . I I I I I C -~- - ::;;J ,.__ I I ,_ I I I ' I ,-L l's. I :=, VALVE ~IT>! DISC PVC 01' POLY SLIPPL Y HEADER Tec:.hllne STAAT CONNECTION MALE ADAPTER Techline® CV TUBING Al'!EA f'E"'-IMETEF!. CITY OF CARLSBAD MAXIMUM APPLIED WATER ALLOWANCE (MAWA) MAWA(residential) = (ETo)(0.62)[(0.55 X LA) + (0.55 X SLA)] MAWA(non-residential] = (ETo)(0.62)[(0.45 X LA) + (0.45 X SLA)] MA.WA Eto 0.62 Maximum Applied Water Allowance in gallons per year Evapotranspiration in inches per year Conversion factor to gallons per square foot 0.55 (R) I 0.45 (NR) LA 0.55 SLA ET adjustment factor (ETAF) for plant factors and irrigation efficiency Landscaped area includes special landscaped area in square feet The additional ET adjustment factor for a special landscaped area Special Landscapde Area in square feet For this project: Residential Landscaped Area Special Landscaped Area Eto for this project is: 0.55 ET adjustment factor 2,986 - 0 47 MAWACalculation (Residential): 47 X 0.62 X 29.14 X [(0.55 X 2,986) 1,642 + + (0.55 XO)] 0 = 47,857 CITY OF CARLSBAD ESTIMATED TOTAL WATER USE (ETWU) ETWU Calculations: Evapotranspiration Rate (Eto)* Conversion Factor (Step 1 x Step 2) Plant Factor (PF) .. (from WUCOLS) (0.1 to 0.8) Area of Hydrozone (sq. ft (HA) (Step 4 x Step 5) Irrigation Efficiency (IE)*** (Step 6 / Step 7) (Total All Step 8 + Total SLA sq. ft. in Step 5) (Step3 x Step 9) Process Step No. (Below) 1 2 3 4 5 6 7 8 9 Hydrozone Number 1 2 3 4 47 0.62 29.14 0.3 0.5 0.8 1,341 1,636 9 402 818 7 0.80 0.80 0.80 503 1,023 9 1,534 MAXIMUM APPLIED WATER ALLOWANCE = 47,857 GALLONS PER YEAR Estimated Total Water !------------------~-----------~ Use in gallons per year (ETWU) -Total shall not exceed MAWA 10 44,697 5 SLA DATE, 08/25/2016 ,1:\J!:!DSC,,,,~ DRAl'IIN SY, EP/HH ~ ~"° '"'"" :Ji) t;/_ 4 .,,J -::. ~. ~ J'-.. ,,, ...YI/_,,,,. ',:, I / ~A,; ~;e---,.1( 'I ,),_ DATE / " J"l.,'I, OS~l,!!i ~ ~EXP.Om r#: OF C/\\.\,o rla 2681 HOWA RD"~ ,:, ,,,, ... .,.,ASSOC I AT Es,, architecture DATE INrTIAL North NTS 5EE 5HEET Cf FOR ADDITIONAL IRRIGATION DETAIL5 5EE 5HEET5 Cf FOR IRRIGATION NOTE5 APPROVED FOR PLANTING AND IRRIGATION ONLY, "AS BUil T" INCLUDING PRECISE TITLE DATE LOCATION OF PLANTING REVIEWED BY: AREAS. 1 sroET I CITY OF CARLSBAD ~ PLANNING DIVISION s HYDROZONE MAP & WATER CALCULATIONS FOR. OUARRY CREEK PA R-3 MODELS I APPROVED ~' I &-t::.l\~ 1-z..-1-.11.c PLANNING DATE DATE INITIAL DATE INrTIAL DWN BY: PROJECT NO. DRAWING NO. avenue ,,. •:.• ,. landsoape 2442 second san diego ca 921 01 619 718 9660 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CHKD BY: CT 15-05 484-5U CITY APPROVAL RVWD BY: PART I -GENERAL I.I GENERAL CONDITIONS, The general cc:mc:lltlons, special conc:lltlone, anc:I Dlvlelon I, are an ac:lc:lec:I part of this section anc:I the contract for this ;;ork shall apply to this !lectlon a& Pully as If repeatec:I herein. 1.2 SC.OPE, The ;;ork lncluc:le!l al I eervlces, labor, materlale,, transportation and equipment necessary to perform the ;;ork Indicated on the dra;;lng" anc:I as 5peclflec:I. O;;ner/developer ;;ill obtain and pay all permit" required by governing authorities. All on site, reclaimed ;;ater piping shall be Installed In accordance ;;1th the uniform plumbing code and all other local governing codes rules c:md regulation. All piping shall be continuously and permanently marked "Ith the manufactu~er's ' name or trademark, nominal elze, and schedule or claes Indicating the pressure rating. PERMITS AND LICENSES Unless other.,,lse stated, secure the required llcenees and permits Including payments c,f charges and feee,, give required nc,tlce!l tc, public authc,rltlee,, and verify permits secured c,r arrangements made by c,ther& affecting the "'"rk of thre sectlc,n. Jlllater meter" and pc,,;er meters ;;!II be the responsibility of the o,;ner and/or his representative for lnstallatlon and permit fees. 1.2.1 RELATED l'IIORK, I. Landscaping sectlc,n 02480 2. Compliance to City of Carlsbad reclaimed "'ater standards 1.2.2 GlUALITY ASSURANCE .I GlUALIFIC.ATIONS OF INSTALLERS Provide at least one person "'h" shall be present at all times during execution of this portion c,f the "'ork and "ho shall be thorc,ughly familiar "Ith the type of materlals being Installed the material manufacturer's recommended methc,ds of lnstallatlon, the City of Carlsbad reclal~ed "'ater standards and "ho shall direct all "'ork performed under this sect!C>n. .2 CODES AND STANDARDS In addition to complying "Ith all pertinent codes and regulations, comply .. 1th the latest rules of the Natrc,nal Electrical Code and Electrical Safety Orders of the State of Callfornla, divisions of Industrial safety, for all electrical "'ork and materials. Refer to the latest edltlc,n of tne Greer-, Book Standard Specifications for public "'orks constructlc,r-, "here applicable. The City of Carlsbad reclaimed ,;ater standard!>, late&t editions anc:I rules and regulotlon fc,r reclaimed ;;oter service In the City of Corlsbad. Latest editions are Incorporated Into these specifications by reference "'here reclolmed "'ater Is proposed. I.S SUSMITTALS, .I Submit complete materiol list prior to performing ony "'ork. Submit cotalog dato onc:I full descriptive l1teroture "'henever the use of Items different than those specified Is requested. Submit notarized certlflcotes by plo!>tlc pipe anc:I fitting monufacturers indicating thot moterlal complies "'ltn speclflcotlon!>, unle"s moterlol has been previously opproved. .2 Submit moterlal list using the follo.,..lng layout (Double spaced bet.,.een each Item) Item Description Monufocturer Model No. I. Pressure Molnllne Loscc, SCH. 40 2. Lo"'n Heod Rainbird 18O6-12F . S Equipment or materials lnstal led or furnished .... rthout the prior approval of tne Londe,cope Architect or City Inspector moy be rejected and such material!> removed Prom tne srte at no expense to the o,;ner/developer. .4 Approval of ony Item!>, alternative, or subetltutlon lnc:llcotes only thot the product(s) apporently meet the requirements of the dro.,,lngs and speclflcotlons on the bos!s of the Information c,r samples submitted. .5 The contractor Is responsible for performance of ,iubstrtuted Items. If substitution proves to be unsotlsfactory, the contractor shall reploce It 1Nith orlglnolly specified Item ot no cost ta the 01Nner/developer. 1.4 GUARANTEE, . I Submit "'rltten guorantee In approved form thot oll "'ork eho.,..lng defect,; In moterlols or ;;orkmonshlp "Ill be repolred or reploced at no coet to the o"'ner/developer for o period of one yeor frc,m the date of occeptance by the 01Nner/developer. .2 The guarontee fc,rm sha 11 be retyped onto the contractor's letterhead and contain the follo,;lng lnformotlc,n, A. Guorantee fc,r lrrlgotlon system -(Project nome). Ylle hereby guorantee tnat tne Irrigation system "'e have furnlsned and lnstol led for (project name) is free From defects In moterlal!O and "'orkmon!>hip, and the "'ork ho" been completed In accordonce .,.,th the dra,;lng" ond specification!>, ordlnory ,;eor anc:I teor and unusual obuse, or neglect excepted. Ylle ogree to repoir or reploce any defects In material or "'orkmc,nshlp "'hlch may develop during the period of I year from date of acceptance and also to repair or replace any damage resulting from the repolrlng or reploclng of &uch defects at no additional cost to the o"'ner/ developer Jl'le shall make such repairs or replacements ,;!thin a reaeonable time, 0!I determined by the o,;ner/developer, after receipts of ,;rltten notice. In the event of our failure to make such repolrs or replacements ;;!thin a reasonable time after receipt of 1Nrltten notice from the OY'!ner/developer, "'e authorize the o,;ner/developer to proceed to have eald repairs or replocements made at our expense and "'e "ill pay the cost,; ond charge" therefore upon demand. 6. PROJECT, (Project name) C. LOCATION, (Legal description of project property) Srgnec:I, Title, Address Telephone Signature and Dote, 1.5 OBSERVATION, 1.5.1 INSPECTION SCHEDULE .I In all ca&ee "'here observation of the sprinkler system "'ork Is required and/or "here portions of the "'ork are &pecif!ed ta be performed under the direction and/or observation of the Land!lcape Architect or City Inspector. The contractor Is responsible For notifying the Landscape Architect or Landscape Coordinator In advance Par the Pollo1Nlng Inspections, according to the time Indicated, A. Pre-Job conference -1 calendar days B. Location of Irrigation sleeve& -48 hours C.. Layout of control equipment, sprinkler heoc:ls and piping -48 hours D. Preesure mainline Installation and testing -48 hour5 E. Conformance to regulations For reclaimed "'ater -48 hours F. Laterol trench depth check -48 hours G. Coverage teet -48 hours H. Flnol Inspection -48 houre I. Nc,trfy the City of Corlsbod 24 hours In advance of beginning "'"rk (160) e,15-61O8 .2 Jl'lhen lnepectlons hove been conc:lucted by other thon the Landscape Arcnltect or the Landscape Coordlnotc,r, sho"' evidence of ,;hen and by Y'lhom these Inspections "'ere made. .S No Inspection .. 111 commence ,;ithout os-built dra .. rngs. In the event the contractor calls for an Inspection ,;ithout as-built dra,;lngs, "'lthout completing previously noted corrections, or "'lthout preparing the system for Inspection, the contractor shol I be responsible for reimbursing the Landscape Architect or the Londecape Coordinator at the rate of $100.00 per hour (plus any transportation coet) For the Inconvenience. No Further Inspections ;;!II be scheduled until this charge has been paid. The city .. 111 require as-built dra,;lng., to be approved prior to backfilling molnllne trench. lh TESTING, GENERAL .I Furnish oil necessory testing equipment and personnel to meet testing requirement. .2 Correct oil defect and retest until acceptance by 01Nner and City. 1.6.1 TESTS . I Moke hydrc,statlc tests only In the presence of the City lnepector $ o representative of the o"'ner/developer. Air preeeure check all lines that could ,;eaken or damoge any major !>tructure5 or hardscope5, If 1Nater "'ere used. No pipe sholl be backfilled until It has been Inspected, teeted, and approved (lncluc:llng os-bullts). .2 Furnish necessary force pump and oil other test equipment. .S Test all preesure mainlines unc:ler a hydroetotlc pressure of 125 P.S.I. For a period of four hours. .4 All testing shall be approved prior to the Installation of remote control valves, quick coupler-s, or other valve assemblies. .5 All piping under paved areas ehall be tested unc:ler a hydrc,stotlc pressure of 125 P.S.I. for a period c,F four hours and provec:I ,;ater-trght, prior to the paving operatrc,n. lh.2 ADJUSTING SYSTEM .I The cantractc,r shall flush ond odjust all Irrigation heads and valves for c,ptlmum performance and to prevent over sproy onto ,;oiks, road,;ays, buildings, "'alls and other structures. .2 If rt I!> determined that adju!>tmente In the Irrigation equipment or nozzle changes ,;Ill provide proper and more adequate coverage, make all such changes or make arrangements "'Ith manufacturer ta have adjustment made, prior to planting. .S Adjust remc,te control volves (battery systems) so that the moet remote sprinkler heads operate at the pressure recommended by sprinkler manufacturer . lh.S. COVERAGE TEST .I Jl'lhen the lrrlgotlon system Is completed, the controctc,r shall perform a coverage test In the presence of the Lanc:lscape Architect, Landscape Coordinator or City Inspector, to determine If the "'oter coverage Par plontrng areas 15 complete and adequote. Furnish oll materials and perform all ,;ork required to correct ony Inadequacies of coveroge due to devlotlone from the plane or "'here the system hos been "'lllfully Installed os Indicated on the drov;lnge "'her-, It Is obviously rnodequate c,r Inappropriate, .. rthout bringing this to the ottentlon of the Landscape Architect or Landscape Coordinator. Thi!> test shall be accomplished before any ground cover of turf Is plantec:I. lh.4 DIRECT BURIAL CONTROL Jl'IIRES .I All "'Iring shall be tested for continuity, open clrcult:s ond unintentional grounds prior to connecting ta equipment. The minimum Insulation resistance to ground sholl be fifty (So) megoohms. Any "'Iring not meeting this requirement shall be replaced, at the contractor's expen&e. lh.5 FINAL ACCEPTANCE .I Jl'lhen all ."'ork under this controct has been completed, Including testing adjustments, additions or deletions, the controctor ,;Ill notify the o"'ner For final Inspection ond apprc,val. Final acceptance by the o"'ner does not relieve the controctor of his responsibility of "'arranty. 1.1 RECORD DRAJl'IINGS, 1.1.1 REC.ORD DRAJl'IINGS . I Record dra.,..ing" shall be prepared and !>hall !>ho"' all change" In the "'ork constituting departures From the orlglnal contract dra.,..lngs Including those Involving both constant-pressure and lntermlttent-preesure lines and appurtenonces. .2 All conceptual or major design changes, Including any changes that may be aHected by the requirements of these !>tandard epeclflcatlons, shall be approved by the 01Nner and Landecape Architect before implementing the chongee In the construction contract. J/'IJthout prior approval the contractor may be required to remove and replace part or all of the system at nls o"'n expenee, to bring rt to the orglnolly &peclfled de&Tgn. Failure to receive prior approval moy result In termrnotron of service. .S Record occurotely on one eet of block and "'hlte prints of the Irrigation dro,;lng!I, al I change& In "'ork constituting deportures from the original contract dro.,..lngs, Including chonges In bath pressure ond non-pressure line. .4 Upon completion of each Increment of ,;ork, tron!>Fer oil such lnformotlon and dimension!> to the prints. Record chonges and dimensions In a legible ond professlonol manner. Jl'lhen the dro,;lngs are approved, tronsfer all Information to a set of reproducible sepia mylar dra;;lngs supplied at cost by the Landscape Architect. 5 Dimension from tv;o permanent points of reference (buildings, monuments, slde.,..alks, curbs, pavement) all Items os required. Post lnfc,rmotlon on as-built drov;lngs day to day as the "ark rs THE FINAL AS-BUil T PLANS J.t'ilLL BE REQUIRED TO BE REVIE~ED AND APPROVED BY THE CITY AND FINAL PLANS J.t'ilLL BE REQUIRED TO BE APPROVED AND SIGNED BY THE CITY PRIOR TO RELEASE OF SECURITIES. Installed. All dimensions noted on dra,;lng& shall be 1/4 Inch In size. h Upon cc,mpletlon of eoch Increment of "'ork, all required Information and dimensions shall be transferrec:I to the record dro.,..lngs. Facilities and Items to be located and verified on the record dra1Nlngs. Sho"' dlmenslonal location and depth of the follo,;rng, A. Point of connection 6. Routing of lrrlgotlon pressure mainlines and all sleeves (dlmenelon maximum 10 feet along routing and all directional changee) C. Sall valves D. Irrigation control valves E. Gulck coupler valves F. Routing of control "'Ires G. Automatic cc,ntrollers H. Other related equipment (as directed by the Landscape Architect) .1 Maintain ae,-bullt dra,;lngs on the site ot all times. These dra.,..rngs are subject to Inspection at anytime. _e, Make oil changes to reproducible dra.,..lnge In Ink (no ball-point pen). Use eradlcotrng fluid "'hen redoing dro.,..lngs. Changes ond dlmen!>lons shall be recorded In a legible and professronal manner. Record construction drov;lngs ehall be morntarned at the Job-site during construction. ."I The Landscope Architect shall provide a complete set of 'as-built' plans to the City of Corl!>bad upon completion of construction. Flnol As-Built plane ,;ill be required to be revle.,..ed and approved by the city and flnols pion!> .... 111 be required to be approved ond signed by the City prior to releose of securities. 1.1.2 CONTROLLER CHART .I Ae-bullt dro .... rngs shall be approved by the Landscape Architect or Londscape Coordinator before charts are prepared. .2 Provide one controller chort of the maximum size controller door .. 111 allolN, Par each controller supplied, eho.,..lng the area covered by that automatic controller and a corresponding legend of the equipment lnetalled. . .S The chart shall be a reduction of the actual as-built system dra.,.lng. If the controller sequence Is not legible ;;nen the droY'llng Ts reduced, enlorge rt tc, a size thot .. 111 be reodoble 1Nhen reduced. .4 Chart shall be blockllne print ond a dlrferent postel transparent color used ta sho"' area of coverage fc,r each station. .5 Jl'lhen completed and approved, hermetically seal the chart bet,;een t"'o pieces of plastic, eoch piece being o minimum 20 mils thick. h Charts shall be completed and approved prior to flnol Inspection of the Irrigation system . 1.1.S OPERATION AND MAINTENANCE MANUALS .I Prepore and deliver to the c,,;ner .... 1thln 10 colendar days prior ta completlc,n of construction, all required and neceseary descriptive material In complete detail and prc,perly prepared in four(4) Individual bound copies. Describe tne material installed In sufficient details to permit qualified operating personnel to under!>tand, operate ond maintain all equipment . Include epare porte list ond related manufacturer Information For each equipment Item installed. Each manual shall Include the follo,;lng, A. Index sheet stating contractor's address and telephone number. 6. Duration of guarantee period. C.. List of equipment "Ith names and addresses of manufacturer's local representative. D. Complete operating and maintenance Instructions on all moJor equipment. . 2 In addition to the maintenance manuals, provide the malntenonce personnel 1Nlth Jnstruct1an" for major equipment and e>holN ,;rltten evidence ta the Landecape Architect or Landscope Coordinator at the conclusion of the ,;ork that hi!> !>ervlce hae been rendered. 1.1.4 CHECK LIST .I Complete the follo.,.1ng checklist at the end of the project, using the format sho.,..n, A. Plumbing permits (If none required, so note) 6. Materlole opproval C.. Preseure mornline test (by ,;hom and elate) D. As-builts dro,;lngs completed (received by ond dote) E. Controller chort completed (received by and date) F. Materials Furnished (received by and dote) G. Operation and maintenance manuals furnished (received by ond dote) H. System and equipment operation Instructions (received by ond date) I. Manufacturer ,;arranteee (received by and date) J. Jl'lrrtten guorontee by contractor (received by and date) .2 For,;ard signed and doted checkliet to Londecope Architect of Landscape Coordlnotor before final acceptance of project. 1.8 GENERAL REGlUIREMENTS, 1.8.1 Code requirements eholl be those of !>tate ond munlclpol ogencles and regulotlone locally governing this "'ork, providing that any requirement,; of the dra.,.Jnge and epeclflcatJon!>, not conrllctlng there;;lth but exceeding the code requirements shall govern, unless "'rltten permission to the contrary 15 grantec:I by the agency. 1.8.2 Extreme care shall be exercised In excovatlng ond "'orklng In the area due to existing utilities. Gontractc,r sholl be respc,nslble for domoges caused by his operations . 1.8.S Connections shall be made at approximately the locations sho"'n on the dro.,..lngs. Cc,ntroctor shall be responslble for minor changes caused by actual site conditions. 1.8.4 Scaled dlmenelons are approximate. Before proceeding "Ith any "'ork, the contractor sholl carefully check anc:I verify oil dimensions. I.eh All lines shall have a minimum clearonce of six (6) Inches from each other, ond from lines of other trade&. Forollel lines ,;hall not be Installed directly aver one onother. 1.8.1 Dielectric bushings sholl b-, used In ony c:.onn-,ctJons "Ith piping of dlsslmllar metal materials. 1.8.8 Pc,lnt of connection sholl be approximately as shc,"'n on dra1Nlngs. Connect ne"' underground piping and valves and provide al I flanges, adapter& or other necessary fittings for connection. I .e."i Permission to shut off ony existing In-use "'ater lines must be obtorned 48 hours In advonce, In "'riting Prom the o"'ner/developer. The controctor shall receive Instructions from the o"'ner/c:leveloper, os to the exact length of time of each shut-off. 1.8.10 Controctor ehall acquaint hlmself 1Nith all elte conditions. 1.8.11 Maintenance. The entire Irrigation sy.,tem snail be under full automatic operation for a period of 1 days prior to any planting. · 1.8.12 The "'ork shall be occepted In 1Nrltlng 1Nhen the entire scope oF 1Nork has been completed to the !>atlefactlon of the o"'ner. No allo.,..ance for deviation from the orlglnal plans and epeclflcatlons "'Ill be made unless previously approved by the OINner. Jl'lhen an!:j Item appeors on the pion and not In the specifications, or In the specifications and not on the plane, It shall be con!>ldered In bath. Jl'lhen confllcte arise, con5ult the Landscape Architect for clarification prior to proceeding. The 01Nner or his authorized reopreo!>entatlve shall have the Pinal authority all Items of tne project. 1.e.1s SERVICE BY THE CONTRACTOR, Theo contractor 5ha II eervlce the sy5tem at the o"'ner 's request during the guarantee period and sholl be paid for "'ork performed ,;hlch Ts not covered by the guorantee. IP reque!>tec:I by the 0Y'!ner, the contractor eholl furnish the OY'lner "'Ith a 5chedule of eervlce Pee for additional ,;ork requested outelde of the guarantee. The contractor eholl engoge the service,; of a professional ,;oter management company approved by the Irrigation de5lgner and provide support service& for the follo"'lng Irrigation equipment, exce"" Flo,; eenelng auto-rain shut off and calibrating !>eneore for excess Pio,; . Inspect ond te,;t controllers and ground foult .. Mote Provide technical support on the Job ,-,rte as requeeted by contractor for controllere, excese flo"' eenslng and auto-rain shut ofF eenslng systems . Training In operotlon of all equipment. Five year limited field eervlce "'arranty Par controller,; ogoJnst orlglnol defecte In materials anc:I ,;orkmonshlp. Jlllarranty 5hall be provided In Y'!rltlng. Available through Hydroscape Products. PART 2 -PRODUCTS 2.1 Materlale,, All materlol5 and equipment ueed In eprlnkler Jrrrgotlon "'ork shall be ne,; and .. rthout fla1Ne or defect" anc:I of quality and performance a" specified. 2.1.1 Piping, Pipe sizes ,iho"'n are nominal lnelde dlometer unless otherv;lse noted . .I POLYVINYL CHLORIDE PIPE ("ALERTLINE") FOR NON-POTABLE Jl'IATER, (I) PVC plastic pressure lines, for piping upstream of remote control valves and quick coupler&. All four (4) Inch and emoller shall be purple colored PVC meeting ASTM-1184, Type I, Grade PVC.-112O, cell class 12546. pipe, ASTM 2241 for SDR cloes pipe, ASTM 2612 for 11Alertlrne 11 • PRESSURE MAINLINE, 1-1/2" and smaller pipe -schedule 40 PVC 2" and lorger pipe -Close Sl5 PVC, SDR-15.5 NON-PRESSURE LATERAL, All non-preeeure pipe -class :200 PVC pipe TYPE I, GRADE I PVC PIPE, Outside diameter of pipe shall be the same a& Iron pipe. Pipe sholl be marked on tv;o sides of the pipe ot 24" Intervals "'Ith "Coutlon Reclaimed Jl'loter". Schedule 40 pipe shall nc,t be threadec:I. Solvent shall be as supplied by pipe manufacturer. Pipe shall be purple Tn color . .2 Bras!> pipe sholl be IFS standard "eight 125 pounds, e5% red braes. APPROVED FOR PLANTING 1.8.5 Plan locations of heads, valves, controller and pipe lines are diagrammatic and lndlcote the spacing and relative locations of all Installations. AND IRRIGATION ONLY, INCLUDING PRECISE DATE, 08/25/2016 LOCATION OF PLANTING TITLE REVIEWED BY: "AS BUil T" DATE ;, \.N•IDS~~ DRAl"IN SY, EP/HH AREAS ~ ~~"" "~ ~ r====+====+=============~========r==~~c~==· J===1==:=it-;::;;;::;;;;::;;::::;-;::::::;::;;:;;:;:::;;:;;:::::~~;::::;:::::;;;:::::;;:;::::;-;::::==::-I ' ;" "'LJ<-Ll'!. (,],\ l------+--+---------------1----1--.1-___J____J ~ CITY OF CARLSBAD ns7 / ;~~"'il"> · l ,;;;' L..LllJ:::::::::::::=-':====PLA:::::N::N:::IN:::G::::::::D::::IV:::IS:::10::::N::::::==::::..'::~::::::::::::~S • \ DAlE i', ,-").' o;,,,,,m , '< '9l"t;---...._ E>P. DAlE -<<f-' OF Cf,1,..1~0 rla 2681 ::HOWARD,:~ '", ~ ASSOCIATES, ,, ., -,, • I an d s c a p e a r ch i t e c t u re 2442 second avenue san diego ca 92101 619 718 9660 DATE INITIAL ENGINEER OF WORK DATE INllL',L DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL IRRIGATION SPECIFICATIONS FOR: OUARRY CR££K PA R-3 MODELS APPROVED j-0>£) (..,.._ ~\ ~ r;:.-i:..1,., PLANNING DATE DWN BY: I I PROJECT NO. DRAWING NO. CHKD BY: RVWD BY: CT 15-05 484-5U ----------- .:2 Polyvinyl chloride pipe fittings and connections, Type II, ~rade I, Schedule 40, high Impact molded fittings, manufactured from virgin compounds as specified for piping, tapered socket or molder thread type, suitable for either solvent "'"Id or sc;re,.ed connections. Machine threaded fittings ond plaetlc; saddle and flange fittings are not ac;c;eptable. Furnish fittings permanently marked ... 1th follo.,.lng Information, Nominal pipe elze, type and schedule of material, and national sanitation foundation (NSF) seal of approval. PVC. fitting shall conform to ASTM D:2464 and D:2466. .5 Bross pipe fittings and connections, Standard 1:25 pound class 85% red brass fittings and connectlone. 2.1.5 RISERS, . I All sprinkler heads shall have risers and s ... 1ng Joints os sho""n In the detail dro.,.Jngs. All risers ond s"'lng Joints shall use Morlex fittings and schedule 80 PVC. risers or nipples. 2.1.4 FITTl~S, .I Fittings, In general, for oil lnstollotlons shall be considered Incidental to the contract price ond shall be the contractor's responsibility to provide oil of required fittings to complete the contract. . 2 All fittings for pipe three (3) inches and smaller shall be schedule 40. . 3 All tees for the lnstollotlon of s"'lng Joints ... 111 be Installed l"llth Dura, Losco Tee or equal. 2.1.5 AUTOMATIC. C.ONTROL I/IIIR.E, . I Electric; "'Iring running from controller to the outomotlc; control valves shall be No. 14 solid, single conductor, copper ,.,re, 4/64 Inch Insulation, 4/64 Inch neoprene Jock.et, fotyle BR (direct burial) or equal, color code ,.,res to each controller, common "'Ire shall be "'hite No. 14 solid, single conductor ,.,re, 4/64 Inch 1nsulat1on, 4/64 Inch neoprene Jacket, style BR (direct burial) or equal. 2.lh MONITOR.I~ DEVIC.ES .I All monitoring devices such os Flo"' ond pressure measuring devices, shall be as sho""n on dro.,.lngs. 2.1.8 AUTOMATIC. C.ONTR.OLLER., .I Automatic controller, Fully automatic; In operation and capable of operating the number of stations of remote control valves as noted. .2 C.Ontroller enclosure assembly, Pedestal mounted os noted, ... 1th a separate stainless steel enclosure, terminal strip, on/off c::IJsc;onnect s ... 1tc;h ... 1110 volt grounded outlet, rolnguarc::I outo-roln shut-off device and locking, hinged cover. Available from Hyc::lroscape Products Inc. 5805 Kearny VIiia Rd., San Diego, C.allfornlo (858)560-1600. . 3 Automatic; controllers shall be of the type one::! manufacturers sho""n on the c::lra.,.lngs and lnstal led per manufacturer's recommendations and detail dra.,.lngs. . 4 All controllers shall be grounded by copper clad grounding rod and general electric; lightning arrestor #<:ILl5DC.BOO2 (50 OHMS resistance required) 2.1."1 REMOTE C.ONTR.OL VALVES, ELEC.TRIC.AL .I The electric remote control valves (pressure regulating) shol I be of the style and manufacturer's eho""n on the dro ... 1ngs, or approved equal, and Installed per detolled dral"ling,; and manufacturer's recommendotlon. .2 Valves shall be Installed a minimum of 6" From oil fixed objects end 12" cpart from each other. 2.1.10 MASTER VALVE .I Shall be of the style and manufacturer's sho""n on the dro.,.lngs, and Installed per details, dra ... rngs end mcnufac;turer's recommendctlons. 2.1.11 VALVE SOX. . I All valves Including pressure regulating valves, master valves, remote control valves, gcte vclves, and quick coupler valves shall be rnstclled In sultcble vclve boxes cs sho""n In detclls. All shall be mG1rked 11PRY", 11MY", 11RCV111 11CY11, or 11DF11 respec.tlvely Nlth stc::1tlon numbers. for control valves embossed on the valve cover. All shall state "R.ec;lolmec::I l/llater" In English end Spanish. (R.c.V boxes shell hove locking covers) Other boxes such os pull boxes, etc. shall be marked ac;c;ordlngly. Valve boxes shall be purple In color. 2.1.12 SPRINKLER HEAD, . I Sprinkler heads shall be as required on the dra ... 1ngs. All sprinkler heads are to hove factory built In check valves or o check valve under each heod. Sprinkler heads shall hove o factory colored "Purple R.ec;lolmed l/lloter" designation os a port of the sprinkler or If not cvoilable be pointed purple as directed by the C.lty of C.crlsbcd. 2.1.13 GUIC.K C.OUPLER VALVES (NON-POTABLE), . I GuJc;k coupling vclves shall be as specified on the dra.,.lngs. Each quick coupler shall hove o molded vinyl locking cover ... 1th ACME threads for reclaimed "'oter service. .2 Upon completion of the contract and prior to final occeptonce, supply the o""ner '"'Ith quick coupler keys and hose ells of the quantity called for In 1rr1gat1on section 2.1.22. The keys and hoses ells shall be of the same manufacturer os the coupling valve. . 3 Shall be I" size as monufacturec::I by Hunter. 2.1.15 BALL VALVES, .I Ball valves three (3) inches and smeller shall be 150 pound base, all brass/bronze construction, single "'edge disc, Integral taper seats, non-rising stem, scre.,.ed bonnets, bronze cross hcndle and a brose/bronze ground Joint union connection at the do""nstream outlet. Valves shall be c;c:,pobls of being repacked ""hlle under pressure. . 2 Ball valves four (4) Inches and larger shall conform to all applicable provisions of section 2.01.08 of the Standard Specifications of the C.lty of San Diego, Document No. 121131. .3 Sholl be similar to those manufactured by Kennedy, Stockham, Nlbc;o or approved equal. 2.1.11 ATMOSPHERIC. VAC.UUM BREAKER, .I Atmospheric; vacuum breaker 3/4" and I" ,;lze shall be mode of heavy duty brass construction preventing bac;k.flo"" of ""oter Into fresh ""ater lines. Operating pressure of 15 to 150 PSI and shall be manufactured by the same manual control valves listed above. 2.1.18 Bock.flol"I Preventer, Unit shall be os sho""n on plans. 2.1.1"1 C.oncrete footings shall be 2POO PSI concrete ot 28 days. 2.1.20 Backfill shall be cleoon fill soil '"'Ith no rocks or clods 1/:2" or larger. 2.1.21 I/IIARNING TAPE, . I Sholl be ploetlc; tape prepared ,.,th silver printing on a purple field having the ""orc::ls, "C.avtlon, R.eclolmed ... ateor line belo"""· Theo overall ""lc::lth shall be 3 lnche5. . 2 il'«:lrnlng (cout1on) tape shall be monufacture>c::I by Thor Enterprise, Inc., P.O. l9ox 450 Sun Prairie, l/lllsconsln, 535"10, (b08) 851-11"11. 2.1.22 I/IIARNING LABELS 4 SIGNS, Sholl be approved by the district engineer to be Installed on designated fccillties. Facllltles euc;h ae controller enclosure as designated by the district engineer or Inspector. See cover sheet for odc::lltlonal requirements . 2.1.23 I/IIARNING TAGS, All reclclmed ""ater sprinkler controls valves shell be tagged ... 1th Identification tags. See cover sheet for addltlonol requirements. 2.1.24 C.Ontractor shall provide to the o""ner, .I Three (3) control valve keys. .2 Four ( 4) "'renches for removing eoch different type of sprinkler head . . 3 T"'o (2) 48" tee ""renc;hes for operating ball valves . .4 Five (5 ea) quick coupler keys and five (5 eo) hose bib oesemblles (potable 4 non-potable). .5 Five (5) keys Por opening and locking each outomctlc; controller . 2.1.25 l/llye "trainer shall be of bronze body '"'Ith sere"' fittings. See details ond dro""lngs. 2.1.:26 In-line pressure regulator shall be os specified on dra""lngs. 2.1.21 Surge arreetors shall be os specified on dro,.lngs. PART 3 -EXECUTION 3.1 ~E:NERAL R.EGUIREMENTS, 3.1.1 Locations on dra.,.lnge are dlagrcmmatlc and approximate only, and shall be changed end adjusted ae necessary as directed to meet existing conditions ond obtain complete ... ater coverage. Locate ond stake all ""ork. and obtain approval of the Lcnc::lscape Architect before Ins ta llotlons. 3.1.2 Install and extend system os sho"'n on the dral"llngs, and ae necessary to c;orry out the Intent of the dra""lng" and speclflcotlone . 3.1.3 Locate lines, valve" and other underground utllltles and receive the approval of the Landscape Architect before digging trenches . 3.1.4 Refer to the c.rty of C.orlsboc::I etondOl'"ds for reclormed pipe Installation. All c.rty of C.orlebod standards toke prec;edenc;e over plans ond 5peclflcatlons for th<> project unl<>se noted and approved. 3.2 INSTALLATION OF IRRl~ATION SYSTEM, 3.2.I EXC.AVATION AND BAC.l<FILLING OF TR.ENC.HES, .I Excavate trenches, prepare subgrade, ond bockflll to line ond grode '"'Ith sufficient room Por pipe fittings, testing ond Inspecting operations. Do not bac;k.fll I until the pipe system hes been subjected to o hydrostatic; test a5 specified. .2 DEPTH OF TRENCH, Polyvinyl chloride preaeure line (less than 3") -18" mlnlmvm Pressure mainlines (3" ond up to 5-1/2") -24" minimum Polyvinyl chloride non-pressure line -12" minimum C.ontrol ,.,re -18" minimum .9 TR.ENC.HING THROUGH AREAS I/IIHERE TOPSOIL HAS BEEN SPREAD, (I) Deposit topsoil on one side of trench and subsoil on opposite 1>lde, . 4 Subsoil shall be Pree of all rocks ·and clods 1/2 Inch In diameter, debris, and litter, prior to use as boc;k.fll I '"'here eo Indicated on detail. .5 Repair ony leok..s ond replace oll defective pipe or fittings until lines meet test requirements. Do not cover any lines until they nave been Inspected and approved for tightness, quality of "'ork.rnanehlp and materlole. .b Bock.fill trenches, arter approval of piping, ... 1th sultcble and approved material, tamping soil around pipe and thoroughly compacting oll trench PIii" until "10% compoctlon hoe been achieved . .i Boc;kflll material shall be on approved soil, free Prom rocks and clode 1/2" and larger. .8 C.ontractor shall not Install pipe across concrete drainage s""ales. C.ontroc;tor shall Jock or bore under s""ole typlcol. 3.2.2 UNDER EXISTING AND/OR PROPOSED PAVEMENT .I Trenches located under orea5 '"'here paving, osphcltlc concrete or concrete '"'Ill be Installed shall be bcc;k.fllled '"'Ith clean fill soil, In o sleeve and c;ompoctec::I In layers to "15% compaction, using manual or mechonrc:.al tamping devices. Trenches for piping ""hlc;h ore not under paving shall be compacted to equcl c;ompac:.tlon of the existing adjacent undisturbed soil and shall be left flush "'Ith the oc::IJolnlng grade. The lrrlgotlon contractor shall set In place, cap ond pressure test all piping under paving prior Eo paving ""ork. .2 Piping under existing pavement moy be Installed by Jock.Ing, boring or hydroullc; driving. Ho""ever, no hydrovlic; driving ""'" be permitted vnder asphalt paving . .3 Provide> o cover oP 18" minimum for mainline (less than 3"), 24" minimum for mclnline (3" ond up to 5-1/2"), 18" minimum for no-pressure line, and 18" minimum for the control "'Ire bet""een the top of the pipe ond the bottom of the aggregate base for all pressure and non pressvre piping lnstoll<>d under osphaltlc concrete paving. .4 Secure permission from the o"'ner/developer before cutting or breaking existing pavement. All necessary repairs and replac;emente shall be approved by o""ner/developer, and shell be at no ac::ldltlonol cost to o""ner/developer. 3.2.3 INSTALLATION OF POLYVINYL C.HLOR.IDE PIPE, .I Because oP th<> nature of pla5tlc; pipe and fitting,;, exercise caution In hcndling, loading and storing, to c:,void damage. .2 The pipe and fittings shall be stored under cover until used, and shall be transported In a vehicle "'Ith o bed long enough to ollo"" the length oP pipe to lay flat so as not to be subjected to undve bending or concentrated external load ot any point. .3 Any pipe thct has been dented or damcged shcl I be discorded until suc:.h dented or damaged section le cut and re Joined '"'Ith a coupling. .4 Trench depth shall be ae specified above from the finish grade to the top oP the pipe. The bottom of the trench shall be free of rocks, clods, and other shcrp-edgec::I objects. .5 Pipe ends and fittings shall be ""lped ... 1th MEI<, or equal, before l"leldlng 5olvent Is applied. l/llelc::lec::I Joints shall be given a minimum of 15 mlnvtes to set before moving or handling. All field cuts shall be beveled to remove burrs and excess before Pitting and gluing together. .b Pipe aholl be snaked from side-to-side of trench bottom to ollo"" for expcnslon and contraction. .i C.enter load pipe '"'Ith small amount of bac;kflll to prevent crchlng end elipplng under pressure. Lecve Joints exposed for Inspection during testing. .8 No ""oter 5hall be permitted In the pipe vntll Inspection have been completed ond o period of at least 24 hours has elapsed for solvent ""eld eettlng and c;vrlng. ."I Plaetlc; to metal Joints shall be mode '"'Ith plostlc; male odoptere, metal nipple hand tightened, plus o_ne turn ... 1th o strop l"lrench. .10 Plostlc; to plastic Joints, Solvent-... eld, using eolvent recommended by pipe monufoc;turer only. .II 5olvent-... eld Joints, Aseemble per manufacturer's recommendation. .12 All pressure pipe 3" or larger shall hove the correct sized concrete thrust block installed ot every abrupt change of ollgnment; ot gate valves, tees, elbo""s, crosses and ends of pipe runs; or "'herever the city engineer deems one to be nec;e5sary. Thrust block shall be Installed os per c::leta I I. 3.2.4 INSTALLATION OF BR.ASS PIPE, .I c.ut brass piping by po,.er hack.sol"I, clrcvlar cutting machine using an obroelve> '"'heel, or hand hack.so"". C.ut no piping '"'Ith metallic '"'heel cutter of any description. Ream and remove rough edges or burrs so smooth en unobstructed flo"" Is obtained. .2 C.arefully and smoothly place on mole thread only. Tighten scre""ed Joints ,.,th tongs or ""renc;hes. C.oulklng 15 not permitted. 3.:2.5 REMOTE C.ONTROL I/IIIRIN~, .I Direct burial control '"'Ire sizes, As sho""n ond specified herein before. .2 Provide one control ,.,re ond one common ground '"'Ire to service eoch valve In system. Provide 2-foot mlnlmvm expansion loop ot eoch valve to permit removal and molntenonc;e of valves. .3 Install control '"'Ires ot lecst 18" belo"" finish grade. .4 Install control '"'Ires ond lrrlgotlon piping In common trenches ""herever possible. .5 Control ,.,re splices, Allo"" only on runs of more than 300 feet, splices as follo""s, (I) Strip off minimum of 2-1/2 Inches of Insulation from each ,.,re. (2) Connecting and splicing of ... rre ot the valves ehall be made using Dura Seal C.rlmp epllces as monvfoc;tured by Raychem corporation. C.ontractor shall refer to Raychem lnstallotlon proc:.edures using ultrotorch 3 heating tool. No other splices ""'" be cllo""ed. 3.2.b AUTOMATIC. CONTROLLER .I Automctlc controller shall be Installed os sho""n end directed. C.Ontroller shall be tested ... 1th complete electrlcal connections. The contrcc;tor shall be responsible for temporcry po,.er to the controller for operation and testing purposes. .2 C.Onnectlons to control ,.,ring ehall be made ... ,thin the pedestal oP the controller. All '"'Ire shall Pollo"' the pressure main In so far as possible . .3 Electrlcol ,.,ring shall be Inc:, rigid PVC. piastre c;ondvlt from controller to electrlccl outlet . A certified electrical contractor shell be responsible> for Installing all "'Iring to the sub-panels, clocks, or elee""here cs required, In order to complete this lnatallatron. A disconnect "'"'Itch eho II be Inc; luded. .4 C.Ontroller shall be Installed '"'Ith vondol-reslstant enclosvres os called for on the dra,.lngs (stclnless steel) oe provided by the monufoc;turer on adequate concrete foundation. 9.2.1 VALVES, .I All valves shall be lnetalled os sho""n In the detalle and In accordance '"'Ith manufacturer's rec;ommendctlons and os required by the C.lty of C.arlebod for Identification, per reclalmec::I ""oter stondords, If used. .2 All automatic valves shall be sized os sho""n on plans. Ball valves shall be line size . .3 Install eoc;h control valve In a 5eporate valve box ,.,th a minimum of 12" separation bet ... een valves ond 6" from any fixed object or structure DAT!=, 08/25/2011:> \.r,l•IDSC4,:,<' DRAJ/'IN BY, EP/HH ~ ~.,.,, Lia ::!'fl o/, ' 'q"~i~ ,,, ~ .... -~ ~ -~ '("\.ll/"\t) ,,:;, r,:;,~, ''"' ' 'Ir, .\ DATE /.., K '/ ">-' ,,.,.,,, ~ -1~-......... EXP. DATE--<¢: o,:-CA\.\~ rla 2681 HOWA RD,:. •" ' 1• ASSOC !ATES ✓ ,, • ,, landscape architecture DATE INITIAL -------------- 3.2.8 VALVE BOX, .I Install valve boxes os sho""n on detail. lnstcll no more than one valve per box. Valve boxes Installed near ""elks shall abut from those items and the top svrfc:,c;es shall be flueh '"'Ith Items lieted above . .2 All boxes are to be mcrked os to the type of valve, control stction nvmber If appllcable ond lc::lentlPJec::I os required, per reclaimed standcrds . .9 Purple vclve boxes required for recycled ""oter. 9.2."1 SPRINKLER HEADS, .I All 5prlnk.ler heads shell be lnetolled os per details sho""n. .2 Nozzle size of all heeds shall be oc::ljuetec::I to suit any particular conditions of the areo. This shall be done after the system has been thoroughly tested, Immediately after l"lrltten notification by the Architect to do eo. 3.2.IO GUIC.I< C.OUPLER ASSEMBLY, .I Install oll quick covplers os lndlcoted on dro""lngs ond os directed. Set all vclves plumb and true to finish grade end o maximum of 12 Inches from paving, ""alk.s, headers or cvrbs, and ae sho""n on plane and a" directed . .2 lnetoll oil quick c:.ovplers In 6" diameter round vc.lve boxes . 3.2.11 GATE VALVES 4 BALL VALVES, 3.2.12 I/IIARNING TAPE, l/llornrng tapes shall be> Jnstolle>c::I directly on top of the pipe longitudinally and shall be centered. The ""c:,rnlng tape shall be Installed continuously for the entire length of the pipe and shall be fastened to each pipe length by piastre; tape bonded orovnd the pipe ,.,th fastenere no more than 5 feet apart. Toping ottoched to the sections of pipe before laying In the trench shall hove flops sufficient for continuous coverage. All risers bet""een the molnllne and control valves shall be lnstolled '"'Ith ""ornlng tape. A second ""orn1ng tape running continuously above piping to be Installed 12 Inches above reclolmed ""cter line. 3.2.13 I/IIARNING LABELS 4 SIGN, Install '"'here sho""n os detailed 3.2.14 I/IIAR.NING TMS, Install '"'here sho""n as detciled 3.2.15 BAC.l<FLOl/11 PREVENTER .I Bock.flo"" preventer assembly shall be lnstolled In oc:.cordance '"'Ith monufoc;tvrer's specifications, located ond os directed on dra""lngs, ond shall conform to all opplicoble code and ordinance requirements. .2 Exact locotlon and positioning shall be verified on the site by the Lonc::lscope Architect. 3.2.16 IN-LINE PRESSURE REGULATORS, .I Adjust and Install per plans and details. 3.2.11 SUR.GE ARRESTOR, .I Install per plans and details. 3.3 C.LEAN-UP, As project progresses, c;ontroc;tor shall molntoln oil areas In a nect manner and r"move unsightly debris doily or os necessary. After completion of the project, controc:.tor shall remove ell debris end containers used In ac;c;omplishlng ""ork. He shall """eep and clean all ,.,c::1.,.,.alk.s, asphalt, ond concrete areas adjacent to the plantlngeo . APPROVED FOR PLANTING AND IRRIGATION ONLY, "AS BUil T" INCLUDING PRECISE TITLE DAlE LOCATION OF PLANTING REVIEWED BY: AREAS. [m CITY OF CARLSBAD ~ 2 PLANNING DIVISION s IRRIGATION SP£CIFICAT/ONS FOR.· QUARRY CR££K PA R-3 MODELS ~o APPROVED 6r-E::.I\ ,ti_. 1 z., i;. r"" PLANNING DATE OWN BY: PROJECT NO. DRAWING NO. DATE INrTIAL DATE INITIAL avenue 2442 second san diego ca 921 01 619 718 9660 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL I I CHKD BY: CT 15-05 484-5U RVWD BY: I ' ' L__-PLANTING 5HOJ/'4N 15 TEMPORARY. AT MODEL CLOSE, INSTALL PERMANENT J/'4ALKJ/'4AY AND IRRIISATION. SEE CITY DJl'«S, II 484-5R 0 5' 10' r l I Scale 1" = 10' rla 2681 HOWARD::,<c .,,,ASSOCIATES- ,, ,, + ~, 1 an d s c a p e a r c hi t e c tu re 2442 second avenue san diego ca 92101 619 718 9660 30' 1 DATE, 08/25/2016 DRAJIIIN BY, EP /HH KEY MAP APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. NTS "AS BU I LT" TITLE DATE REVIEWED BY: ~ CITY OF CARLSBAD i1sl f----f--+-----------------11---t---t-----t----i ~ PLANNING DIVISION ~ l---+---+-------------+-----+----t--1------1 PLANTING PLAN FOR' OUARRY CR££K PA R-3 MODELS I APPROVED {'t2Qll 4:-8)& lv1-t~ PLANNING DATE DATE INrTIAL ENGINEER OF WORK REVISION DESCRIPTION DWN BY: PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: CT 15-05 484-5U OTHER APPROVAL CllY APPROVAL RVWD BY: PLANTING NOTES I. THE CONTRACTOR SHALL PROTECT IN PLACE ALL EXISTINIS PLANTER AREAS AND PLANT MATERIAL AS INDICATED ON THE PLANS OR AS SPECIFIED IN THE FIELD SY THE LAND5CAPE ARCHITECT. 2. THE PLANTINIS PLAN IS DIAISRAMMATIC. ALL PLANT LOCATIONS ARE APPROXIMATE. S. APPLY A CONTACT HERBICIDE, l'IIHERE l'IIEEDS ARE PRESENT, PER MANUFACTURER'S SPECIFICATIONS, A MINIMIJM OF TEN DAYS PRIOR TO COMMENCEMENT OF ANY PLANTIN<S OR IRRIISATION l'IIORK. l'IIEEDS, INCLIJDINIS THEIR ROOTS, SHALL SE ALLOl'IIED TO COMPLETELY DIE SACK SEFORE PROCEEDINIS l'IIITH l'IIORK. 4. SOIL TESTINIS SHALL COMPLY l'IIITH SECTION 4, PART F OF THE CITY OF CARLSBAD LANDSCAPE MANIJAL. 5. FOR LAND5CAPE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUSIC YARDS PER IPOO 5GUARE FEET OF PERMEABLE AREA SHALL SE INCORPORATED TO A DEPTH OF SIX INCHES INTO THE SOIL. SOILS l"IITH ISREATER THAN 696 ORISANIC MATTER IN THE TOP 6 INCHES OF SOIL ARE EXEMPT FROM ADDINIS COMPOST AND TILLINIS 6. PRIOR TO PLANTINIS OF ANY MATERIALS, COMPACTED 50IL5 SHALL 6E TRANSFORMED TO A FRIABLE CONDITION. ON ENIS I NEER.ED SLOPES, ONLY AMENDED PLANTIN<S HOLES NEED MEET THE REQUIREMENT OF THIS SECTIONS. 1. SOIL AMENDMENTS SHALL SE INCORPORATED ACCORDINIS TO THE RECOMMENDATIONS OF THE SOIL ANALY5I5 REPOT5 AND l"IHAT 15 APPROPRIATE FOR THE PLANTS SELECTED. e. BACKFILL SHALL COMPLY l"IITH SECTION 4, PART F OF THE CITY OF CARL5SAD LANDSCAPE MANUAL. •t PLANTS SHALL SE INSTALLED PER PLANTINIS DETAILS PROVIDED IN THESE PLANS. PLANT MATERIAL SHALL NOT SE ROOT SOUND. FIVE ISALLON PLANTS AND LARISER SHALL HAVE SEEN ISROl"IN IN CONTAINERS FOR A MINIMUM OF 6 MONTHS AND MAXIMUM OF Tl'IIO YEARS. PLANTS SHALL EXHIBIT HEAL THY ISROl"ITH AND 6E FREE OF Dl5EA5ES AND PE5T5. 10. STAKE ALL TREES PER DETAIL. REMOVE NURSERY STAKES AND TIES FROM ALL CONTAINER STOCK. MAINTAIN SIDE ISROl"ITH ON ALL TREES. II. PLANT ALL AREAS l"IITH ISROUNDCOVER TO l"IITHIN 6" OF 5HRUS OR TREE TRUNKS. 12. PLACE PLANTS NO CLOSER THAN 24" TO SPRINKLER HEADS, EXCLUDIN<S ISROUND COVER IS. ALL ISROUND COVERS SHALL SE OOARANTEED SY THE CONTRACTOR A5 TO ISROl"ITH AND HEALTH FOR A PERIOD OF SIXTY DAYS FOLLOl"IINIS COMPLETION OF THE MAINTENANCE PERIOD AND FINAL ACCEPTANCE OF THE PROJECT SY THE Ol"INER OR Ol"INER'5 REPRESENTATIVE. ALL 5HRUS5 SHALL SE ISUARANTEED SY THE CONTRACTOR A5 TO <SROJ/IITH AND HEAL TH FOR A PERIOD OF SIXTY DAYS FOLLOl"IINIS COMPLETION OF THE MAINTENANCE PERIOD AND FINAL ACCEPTANCE OF THE PROJECT SY THE Ol"INER OR Ol'IINER'S REPRESENTATIVE. ALL TREES SHALL SE i:;.UARANTEED 6Y THE CONTRACTOR A5 TO ISROl"ITH AND HEALTH FOR A PERIOD OF Tl"IELVE MONTHS FOLLOl"IINIS COMPLETION OF THE MAINTENANCE PERIOD AND FINAL ACCEPTANCE OF THE PROJECT SY THE Ol"INER OR Ol"INER'S REPRESENTATIVE. THE CONTRACTOR., l"IITHIN 15 DAYS OF NOTIFICATION 6Y THE LANDSC.APE ARCHITECT OR Ol"INER, SHALL REMOVE AND REPLACE ALL ISUARANTEED PLANT MATERIALS l'IIHICH FOR ANY REASON FAIL TO MEET THE REGIJIREMENTS OF THE ISUARANTEE. REPLACEMENT SHALL SE MADE l'IIITH PLANT MATERIALS A5 INDICATED OR SPECIFIED ON THE ORIISINAL PLANS, AND ALL 5UC.H REPLACEMENT MATERIALS SHALL 6E ISUARANTEED A5 SPECIFIED FOR THE ORIISINAL MATERIAL GUARANTEE. 14. THE APPLICATION OF ORISANJC, MULCH MATERIALS MADE FROM RECYCLED OR POST-CONSUMER. MATERIALS SHALL TAKE PRECEDENCE OVER INORISANIC MATERIALS UNLE55 RECYCLED OR. P05T-CON5UMER ORISANIC MATERIALS ARE NOT Loe.ALLY AVAILABLE. 15. PROVIDE AS" LAYER OF ORISANIC MULCH IN ALL NON-TURF PLANTING AREAS FLATTER THAN Sd 16, l"IHERE TREES AND 5HRUS5 ARE PLANTED ON 5LOPE5, THE FRONT 4 REAR OF THE PLANTINIS PITS SHALL 6E ISR.ADED TO MAX. Id SLOPE. EROSION CONTROL FABRIC SHALL 6E INSTALLED ON THESE SLOPES. 11. THERE SHALL SE A 296 POSITIVE <SAADE IN PLANTINIS AREAS Al"IAY FROM STRUCTURES AND TERMINATING IN AN APPROVED DRAINAISE 5Y5TEM-5EE CIVIL EN<SINEER PRECISE ISRADINIS FOR ALL DRAINAGE AND ISRADIN<S. PREVAILIN6 l'IINo AXIS 0 'TREE PLANTcI) !'Els t:>el'AIL ® STAKE BEL.ON CFICl'IN OF 'TREE © "l"ION!>ER 'TREE TIES" OR A'FPROVEC) EGIUAL. SEGU~ l'IITH 16<1 ISALVANIZED NAIL i:I TOTAL) ·-.· 5 . . IL--=__,,_ \ POT LEGEND SYMBOL POTTINIS NOTES BOTANIC.AL NAME/SIZE (S) 5 GAL. PHORMIUM 'YELLOV'l V'lAVE' 15 GAL. NANDINA 'OBSESSION' 5 GAL. EURYOPS VERIDIS 15 GAL. FATSIA JAPONICA 5 GAL. LOROPETALUM CHINENSE 'SNOV'l PANDA' 15 GAL. FIC.US BANJAMINA 5 GAL. LOROPETLUM C.HINENSE 'SNOV'l PANDA' 5 GAL. ABUTILON HYBRIDUM 5 GAL. AGAVE 'BLUE GLOV'l' 15 GAL. PITTOSPORUM 'SILVER SHEEN' (S) I GAL. AGAVE ATTENUATA 15 GAL. AGAVE ATTENUATA MUL Tl (MATCHED) ~ I. POTS SHALL 61: PER POTTIN5 SCHE:DUL.E: I. MOOULAR LITE, OBSIT, AVEN.IDA, PIGG-ADILLY LITE• OVAL LITE PL.A~ AVAIL.Aa..l= AT, l"l)'olr-1.Garnpanlci!nte,-nat.lonal.GOm. Tl:DOPU; PLANTcRS AVAILABLE AT, ~uatea"ldban-el;;cm .2. BACKFILL POTS l"IITH lo:ELL.055'S SUPPLY MIX OR EQUAL AS APPROVEV SY LANDSCAPE ARCHITECT :l. PROVIDE PLANT TASS PER PLANTIN5 NOTES 2. ~ ""'ILL EACH POT l'IITH (2) ,!" HOLES IN SASE TO ALIISN l'llTH DAAINAISE e IRRIISATION 51.EEVES. 4. ORDER ALL POTS MIN. 4 ~EKS IN ADVANCE; OF DEaLIVEaRY. 5. l'!<OVIDE (2) ,!'~IN CONC1"E'l'le PATIO UNDER EACH POT (I) I' DAAINLINE AND W I" IRRIISATION TUBIN6 51.EEVE 5. POTS AVAILABLE: THROU5H, GAMPANIA INTERNATIONAL-"'"'"'·G"mpanlalnl:ernatlonol.c:.om 6. UNDE:R-PLANT ALL POTTeD PLANTS ~!TH ANNUAL 6.1. DAAINLINE, ALle.N ,!• PVC DAAINLINE l'IITH GENT1aR OF POT AND CONNECT TO AREA C1RAIN S'r"STEM. INSID!: POT EXTEND PVG RISER TO I'" .5. 01"' POT OOTTOM' AND CAULK ~"TER. Tl6HT. f'RO\IIDE A :2• LAYER OF GRI.JSHED FICGK IN BOTTOM OF POT, l'IJTH A FIL TEI< FABRIC COVER PRIOR TO F'I.ANTIN6. COLOR IN 4" POTS. PLAN POT# I PLAN 2 2 s 4 PLAN I 5 E;, 1 8 "I PLAN B 10 11 12 IS 9.2. IRRIGATION SLEEVE, EXTENr} 2" PVG l'ftRl6ATION Sl.EEVE TO F.6, OF P~ POT. THREAD ¼" DRIP TUSINISLIN!a THRU 51.HVE AND CONNECT TO ADJACENT NETAFIM 1~6ATION HEADcR IN C,OIJR,iYARP PLANTER Brn. PROVIOE: AAINBIRO MUL TI-OUTI..ET XE:RI--BL/6 EMl"l'"n=R. XB-lo-6 AT F.6. OF PLANTER ANO GONNEGT 1-6 TIJBeS TO PORTS AS AF'f'ROPRIAiE FOR. cAGH PLANT. GAF l.ll"IJSeO PORTS. PROVIDE i1JSIN6 STAKe ANt' eLJe,, GAP FO!lt EACH OU"T1..l!T', SUPPLIER (OR EQUAL AS APP'D BY L. ARC.H) / MODEL / C.OLOR MODLAR LITE ML-REC.T SE;,18 RUST LITE 55.5" X 11.15" X 11.15" MODULAR LITE ML-SQ-1818 RUST LITE 11.15" X 11.15" X 11.15" RUST LITE SQUARE RIO PLANTER MEDIUM 11.15" X 2E;>.15" TIDORE SQUARE IE;>" PLANTER #512521 TIDORE TALL 21.5" PLANTER #51258E;> TIDORE SQUARE IE;>" PLANTER #512521 TIDORE TALL 24" PLANTER# 512555 TIDORE TALL 24" PLANTER# 512555 OBSIT SQUARE PLANTER 18."I" X 18."I" C.OLA AVENIDA PLANTER ONYX BLAC.K LITE. 24.8" X 2Ih" PIC.C.ADILL Y LITE PLANTER, ONYX BLAC.K LITE. 11.15" X 8.15" TALL OVAL LITE PLANTER, RUST LITE 24.15" X 15.25" Z 2E;>.15" TALL AND LITE PLANTER, RUST LITE, 20.15" X 12.5" X 22.5" 0 VINE ATTACHEP TO ~Ac.E OF AALL OR rENCE Yf.lTI-1 VINE TIES ® EXl5TIN6 i"W-L ORF~ @ P.LANT 50 THAT GROl'IN I$ 111 ABOVE FINISH O\RAI:>E 0 :211 :C,IAMeTcR X 10' LON6 I..ODO\EPOLE PIN!a STAKE (2 TOTAL) ® l<OO'IBALL 0 ROOT B.ARRIER, I~,!!," PEEP ''Bio-BARRIER" ® PAVED SURFAcE 0 4" l'IA TERING BASIN © PLANT TABLETS PER F'LANTIN6 NOTES OR 5PECIFICATION5 © FINISH 6RADE c;fCTION NOTTO SCALE NO't'?:1 ALSO SEE ~ F'LANTIN6 t:>el'AIL Nc::nt:, USE SINtsl..c STAKE fOR. 50\AL.Tl<EES. ALSO !!Ee NOTE 14 AE>OYE. W Tree Staking v:Yi--------=-------NOTTOSCAI.E © FINISH ISRAI:>E 0 FICOTSALL ® -- @ Root Barrier NOTE, "°"T BARRIER SHALL SE IN5TALLED FOR ANY Tl'!EE l'IITHIN 5' OF A PAVll-1$. 0 SAcKFILL HIX PER PLANTIN6 NOTES OR SPECIFICATION5 0 2X ROOTSALL DIAMETER 0 IJNDIS'MOSEl:I NATIVE SOIL NOTTO SCALE @ FICOTSALL ©1--V_in_e_P_la_n_t_in~g~---------------,"°..,..,""'F"'m.,..,,---N 0 "TREE OR SHl"IJS l<OO'IBALL ® DI<!\ HOLE 2X l'IIDTH AN!> DEPTH OF FICOTSALL AN!> FILL l'IITH l'IATER AN!> ALLOl'I TO PERCOLATE INTO SUBSOIL. © FILL HOLE l'IITH 6" DEPTH NATIVE SAcKFILL MATERIAL. TAMI" ANo HOUND 51.IISHTL Y. 0 SET FICOT SALL IN HOLE SO THAT "°"T CFICl"IN IS I" AB0V£: FINISH 5RAOE. DATE, 08/25/20IE;> DRAV"-IN BY, EP /HH Plant Legend SYHSOL BOTANICAL NAME COMMON NAME SIZE TREES [g] ARSIITIJ5 MARINA 'HUI. Tl' 5TRAl"ISERRY 1l<EE 96" BOX M MAcSNoLIA 'LITTLE .,;E;M' HAcSNoLIA se• eox cs CUPRl35U5 SEMPE!O.VIRENS ITALIAN CYPRESS 66" eox PO PODOCARF'US O\RACILIOR FERN PINE: 5611 OOX TR TRISTANIA CONFERTA BRISBANE SOX 24~ eox e6" eox SHRU65 ® ABELIA O\RANDIFLORA ISLOSSY ASELIA 15 ISAL. AcSAVE ATTENUATA AcSAVE 15 <!\AL. ~ ARSIJT1,l5 UNE:DO Di'IARI" STRAl'ISERRY TREE 1!5 e.AL. @) BESc.HoRNERIA 'F. cSLOl'I' l"ALSE Ra> YUCCA 15 ISAL. e SOI.IGAINVIL.l.E:A 'ROSENKA' SOUcSAINVIL.1.E:A SISAL. ffi CUF'RE55U5S SEHP. i-rNY TOll'IER5' 1:>i'IARI" ITALIAN CYPRESS 15 ISAL ® DIETES 6ICOLOF1. FOF1.TNl6HT LILY 5 ISAL. e DODONAEA VISCOSA HOf'SEED SIJ5H SISAL. C CARISSA 'Di'IARI"' Di'IARI" NATAL PLUM I e.AL. F l"ICUS SENJAMINA l"ICUS 15 <!\AL. "' cS!OEV'IIA OCCIDENTALIS LAVENDER STARFLOV'IER 15 <!\AL. L LIO\USTRIJH TEXANUM PRIVET 15 6AL. 0 M'\"RTIJS COMM. COMP. MYRTLE 15 6AL. ~ PODOCARPUS HENKEL.II 'COLUMN' LONcS LEAFED YELL.Ol'I l"IOOD 15 cSAL. RHAPHIOLEPIS HA..ESTIC BEAUTY STD. INIDIAN HA-"ITHORN @ SALVIA 'l'IINNIFRED cSILMAN' SA<Se e 5T'F<Eal.lTZIA FmSINAE BIRD OF PARADISE V VIBURNUM JAPONICUM VIBURNUM p F'HOF1.MIUM YEL.l.Ol'l i'IAVE' Nel'I ZeALANID PLAX SMALL SHRUBS @) AISAPANTHUS OF1.IENTALIS LILY OF THE NILE 0 ASPARAJSUS 'ME'T"ERI I ASPAl<AcSl./5 FERN @ CALANDRINIA SPP. ROCKRJRSI..ANE \Ip LIRIOFE MU5CARI LIL YTIJRI" <!\ROUND COVER ~ MYOPOF1.IJM ~TAH CREEK' CFIEEPIN6 MYOPOF1.IJM m TRACHELOSPERMJM JAS. STAR JASMINE: VINES v-iJ--v MACFADYENA UNGUIS-GATI CAT'S CLAl'I ,._,....___, l'RACHEL05f"ERHJM JASMENolDE5 STAR JASMINE IMl'QBTANT NOTE, ~IZE P'ROO\JGTION f'l..AHTIN6 Sl-fOYIIN. CN f'LANTINe f'LAN /16 Fc:>I.J..Ot"e, • TREES Jt,,5 ~ OUT ON F'L.ANS • !5f::IRl,ll;%2 !!6AL IQ to •1 Q) 1::,1!,~ ~ (y ~I""'"""" """"""' @ F'HOl<HIUM ,..,,_ BABY' @) PITT05PO!iVM VAA.. • Sl:JRIJM, If-Al TO !5f-,6J,, ; ~I& P!:NNISETUM RUel'JJM A6Al"ANTHJ5 • CSFQLNPGQY!:R 5tfBUB 5f'AC:IHO I 6AL.. !IQ" Q.G TQ 12' Q.G 11!1/i!i GEANO'!HJ5 'fANl<f3S f'01N"r ~ ijlS'TUS &AL.Vlf'QL.I~ APPROVED FOR PLANTING 96" BOX 15 cSAL. 56AL 1!5 cSAL. 15 <!\AL. SISAL. !5 cSAL. SISAL. SISAL. I cSAL. I cSAL_ IS ISAL. 15 ISAL. GTY l~J 1'11./COL 1!5'Xl:!5' L 5 20'XIO' M 2 .2S'XIO' L 2 ::ZO'Xl::Z' M 6 40'.><SO' M 4 II 4'X4' M 5 44.'<4' L ; e·xe· L l!5 5'X5' L l"T 5'><'.5' L ; e'X:2' L 4!5 5'X9' L 25 !S'.><e" L 24 4'X4' L 5 e·xe· M 6 e·xe• M 45 e·xe· H 4 6'.><e' L e :25'>0:0' M IOXIO H 15 5'X5' L I 6'><e' L 2 a•xa· M 4'X4' L 110 2'X2' M 50 2'X2' M 1!5 ::Z'X2' L a 2'><2' M 121 O.G. 2'XS' L 12" O.G 2·x101 M re 5TAKeD L 2 ESPALIER M AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS BUil T" TITLE DATE REVIEWED BY: © REPLACE BAGKFll.L MATcRIAL ~R SOILS REPORT) UP TO '2/5 THE ,EIISHT OF THE FICOT BALL, TAMF'IN6 AND fETTI_./N6 AROUND REHAININIS 1/3 OF FICOT SALL. ~ CITY OF CARLSBAD l1Sl 1-----11---+----------------t---+--f-----t------f L.]_iJ PLANNING DIVISION ~ ~P::::LA=:::N;:;T::::IN:;:'.G_;&::;P::::O:::T;:;T:;:E::::RY===LE::::G::::E;:N:::D=, ;;:D::::ET::::A:::IL::;S::&::N:::0::::T;::;E;::;S:::F;::;O:;R=: :::...:::==::::; ~ 5ROUNPCOVER PLANTI:DPER PLANTIN<S LE<SENP © Groundcover Spacing D 1---------'---=---------NOT-TO-SCAL--,-,-::E $J;C[)QN 'NOT TO SGALE NOT'E:1 ALSO SEE TRe: STAKINIS t:>el'AIL 0 CREATE IRRIO\ATION SASIN A HINIMJH OF 6" SEYONo SIDES OF "°"T SALL. G) IRR.h&ATI: ~ TOf' TO SETTU: BACKFILL ANP eERH, l"ILL!l-1$ SASIN. 0 FINISH !SR.ADE 0 FERTILIZER TABLcTS PER SOILS Rl:PORT ® Tree/Shrub Planting E f--------NOTTOSCALE rla 2681 HOWARD::' ".,ASSOCIATES, ,. ,, ,. ,, 1 ands cape architecture 2442 second avenue san diego ca 92101 619 718 9660 DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION QUARRY CREEK PA R-3 MODELS I APPROVED l~( f:.11 &: I ~-tz--r. ' la PLANNING DATE OWN BY: PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: CT 15-05 484-5U OTHER APPROVAL CITY APPROVAL RVWD BY: SECTION 02483 • LANDSCAPE FINISH GRADING AND PLANTING 1. GENERAL THE GENERAL AND SPECIAL CONDITIONS OF THE CONTRACT APPLY TO THE WORK OF THIS SECTION AS THOUGH WRITTEN HEREIN. 2. SCOPE OF WORK 2.1 FURNISH ALL LABOR MATERIALS, AND EQUIPMENT TO PROVIDE AND INSTALL SOIL PREPARATION, FINISH GRADING, AND PLANTING AS DESCRIBED HEREIN AND UPON THE PLANS. 2.2 THE CONTRACTOR SHALL ADEQUATELY PROTECT THE WORK, ADJACENT PROPERTY, AND THE PUBLIC, AND SHALL BE RESPONSIBLE FOR ANY DAMAGE, INJURY, AND LOSS DUE TO HIS ACTS OR NEGLECT. 2.3 WORK NOT INCLUDED: ROUGH GRADING AND DRAINAGE. 3. SAMPLES, TESTS, AND INSPECTIONS 3.1 THE SOURCE OF THE PLANT MATERIAL SHALL BE FURNISHED IF REQUESTED BY THE LANDSCAPE ARCHITECT. 3.2 ANY SAMPLING, TESTING, OR INSPECTION COSTS OF MATERIALS ARE TO BE BORNE BY THE CONTRACTOR, AND COPIES OF INSPECTION CERTIFICATES, REQUIRED BY LAW, SHALL BE FURNISHED TO THE OWNER WITHOUT CHARGE. 3.3 THE LANDSCAPE ARCHITECT MAY, AT THE OWNER'S REQUEST, VISIT NURSERIES AND TAG SPECIFIC TREES FOR INSTALLATION. 4. MATERIALS PLANTS: 4.1 NOMENCLATURE: SEE PLANT MATERIALS LABELED ON LANDSCAPE PLANTING PLAN. 4.2 CONDITIONS: PLANTS SHALL BE SYMMETRICAL, TYPICAL FOR VARIETY AND SPECIES, SOUND, HEAL THY, VIGOROUS, FREE FROM PLANT DISEASE, INSECT PESTS OR THEIR EGGS, EXCESSIVE ABRASIONS OR OTHER OBJECTIONABLE DISFIGUREMENTS, AND SHALL HAVE HEAL THY, NORMAL ROOT SYSTEMS, WELL FILING THEIR CONTAINERS, BUT NOT TO THE POINT OF BEING ROOT BOUND. TREE TRUNKS SHALL BE STURDY AND WELL HARDENED-OFF. PLANTS SHALL NOT BE PRUNED PRIOR TO DELIVERY EXCEPT AS AUTHORIZED BY THE LANDSCAPE ARCHITECT. IN NO CASE SHALL TREES BE TOPPED OR PRUNED BEFORE DELIVERY. PLANTS SHALL BE GROWN IN NURSERIES WHICH HAVE BEEN INSPECTED BY THE STATE DEPARTMENT OF AGRICULTURE AND HAVE COMPLIED WITH ITS REGULATIONS. 4.3 IDENTIFICATION: PLANTS SHALL BE OF THE VARIETY AND SIZE REQUIREMENTS HEREIN. ONE OF EACH BUNDLE OR LOT SHALL BE TAGGED WITH PLANT NAME IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN ASSOCIATION OF NURSERYMEN. 4.4 SUBSTITUTIONS: SUBSTITUTIONS FOR THE INDICATED PLANT MATERIALS MAY BE PERMITTED, PROVIDED THE SUBSTITUTE MATERIALS ARE APPROVED IN ADVANCE BY THE LANDSCAPE ARCHITECT AND CITY LANDSCAPE INSPECTOR AND THE SUBSTITUTIONS ARE MADE AT NO ADDITIONAL COST TO THE OWNER. EXCEPT FOR THE VARIATIONS SO AUTHORIZED, ALL SUBSTITUTE PLANT MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THESE SPECIFICATIONS. IF ACCEPTED SUBSTITUTE MATERIALS ARE OF LESS VALUE THAN THOSE INDICATE OR SPECIFIED, THE CONTRACT PRICE WILL BE ADJUSTED IN ACCORDANCE WITH THE PROVISIONS OF THE CONTRACT. 4.5 PLANT INSPECTION AND REJECTION: ROOT CONDITION OF PLANTS WILL BE DETERMINED BY THE LANDSCAPE ARCHITECT THROUGH THE REMOVAL OF EARTH FROM THE ROOTS OF AT LEAST TWO PLANTS BUT NOT MORE THAN 2% OF THE TOTAL NUMBER OF SPECIES FROM EACH SOURCE. 5. MATERIALS 5.1 SOIL AMENDMENTS: ALL AREAS TO BE PLANTED AND IRRIGATED WHICH ARE LESS THAN 3:1 IN SLOPE ASPECT SHALL RECEIVE SOIL AMENDMENTS, UNLESS OTHERWISE NOTED. THE FOLLOWING SOIL AMENDMENTS ARE TO BE USED AS THE BASIS FOR BIDS. ONCE ALL SITE IMPROVEMENTS ARE IN PLACE AND APPROXIMATE FINISH GRADES ESTABLISHED, THE CONTRACTOR SHALL FURNISH TO THE OWNER A SOILS REPORT MADE FROM THE SURFACE AND SUBSURFACE (18' BELOW GRADE) SOIL BY SOILS AND PLANT LABORATORY, P.O. BOX 11744, SANTA ANA, CALIFORNIA 92711; (714) 558-8333. THE REPORT SHALL INCLUDE PH, N.P.K., SAR, ECE, BORON LEVELS, AND SOIL PARTICLE EVALUATION. LANDSCAPE ARCHITECT & CITY INSPECTOR SHALL REVIEW & APPROVE THIS REPORT PRIOR TO COMMENCEMENT OF SOIL PREPARATION OR PLANTING. GENERAL SOIL PREPARATION, AMOUNT PER 1,000 SQUARE FEET: A NITROGEN STABILIZED ORGANIC AMENDMENT, 3 CY. YDS., DERIVED FROM COMPOSED REDWOOD SHAVINGS OR FINELY GROUND FIR OR REDWOOD BARK. SHALL CONTAIN A MINIMUM 0.5%AVAILABLE NITROGEN. B. 200 LBS. GRO-POWER PLUS (SO. CAL. ORGANIC FERTILIZER COMPANY). C. 200 LBS.AGRICULTURAL GYPSUM. . D. 10 LBS. SOIL SULFUR. 5.1.1 BACKFILL MIX: A 6 PARTS BY VOLUME ON-SITE SOIL B. 4 PARTS BY VOLUME ORGANIC AMENDMENT PER ABOVE. C. 10 LBS. GRO-POWER PLUS PER CU. YD. OF MIX. D. 2 LBS. IRON SULFATE PER CU. YD. OF MIX. E. 10 LBS. AGRICULTURAL GYPSUM PER CU. YD. OF MIX. 5.1.2 A COPY OF DELIVERY SLIPS ON ALL MATERIALS USED ON THE PROJECT SHALL BE DELIVERED TO THE OWNER. 5.1.3 SUBSTITUTIONS WILL NOT BE PERMITTED EXCEPT WHEN PROOF OF SUBMITTED THAT ANY MATERIAL SPECIFIED IS NOT OBTAINABLE. ALL SUBSTITUTIONS ARE SUBJECT TO REVIEW BY THE OWNER. 5.2 TREE STAKES: TREE STAKES SHALL BE 2: IN DIAMETER BY 10' LONG NEW PINE LODGE POLES TREATED WITH COPPER NAPTHENATE UNLESS OTHERWISE NOTED. 5.3 TIES: 5.3.1 PER PLANTING DETAIL. 5.4 IMPORT SOIL OR TOPSOIL: 5.4.1 NATURAL FRIABLE SOIL POSSESSING THE SAME CHARACTERISTICS OF THE EXISTING SITE SOIL. PROVIDE SOIL FREE FROM SUBSOIL, BRUSH, OBJECTIONABLE WEEDS, ROCKS, ORGANIC OR INORGANIC DEBRIS, AND CLAY. THE SOIL SHALL BE FREE OF ANY TOXIC SUBSTANCES, ORGANIC OR INORGANIC, SOIL STERILANTS, SAL TS; AND NO SOIL REMOVED FROM ROAD BED EXCAVATIONS. 5.4.2 THE CONTRACTOR SHALL FURNISH UPON THE REQUEST OF THE LANDSCAPE ARCHITECT A SOILS REPORT MADE FROM THE INTENDED IMPORT BY SOIL AND PLANT LABORATORY. SEE SECTION 5-A OF THESE SPECIFICATIONS. THE REPORT SHALL INCLUDE PH, N.P.K. SAR, ECE, BORON LEVELS, AND SOIL PARTICLE EVALUATION. ANY SOILS IMPORTED TO SITE AND FOUND TO BE UNSUITABLE BY THE LANDSCAPE ARCHITECT SHALL BE REMOVED FROM THE SITE AND REPLACED WITH AN APPROVED SOIL AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR SHALL PAY ALL EXPENSES FOR SOIL TESTING OF IMPORT MATERIALS. 6. INSTALLATION 6.1 SCHEDULING: PLANTING SHALL NOT COMMENCE UNTIL COMPLETION OF ALL CONSTRUCTION WORK, GRADING, SOIL PREPARATION, WEED CONTROL AND SPRINKLER INSTALLATION. ALL CONTAINER STOCK SHALL BE SPOTTED ON-SITE BY THE CONTRACTOR PER PLANS PRIOR TO PLANTING. PLANT PITS SHALL NOT BE EXCAVATED UNTIL THE REVIEW OF PLANT LOCATIONS BY THE LANDSCAPE ARCHITECT. 6.2 SOIL PREPARATION: 6.2.1 IRRIGATE SITE NORMALLY FOR TWO WEEKS TO GERMINATE WEEDS. APPLY CONTACT HERBICIDE PER MANUFACTURER. REPEAT PROCESS IF REQUIRED BY LANDSCAPE ARCHITECT. 6.2.2 APPLY SOIL AMENDMENTS AS SPECIFIED, EVENLY AND AT THE SPECIFIED APPLICATION RATES. 6.2.3 ROTOTILL TOP 6' OF SOIL TO A LOOSE AND FRIABLE CONSISTENCY. 6.2.4 FINISH GRADE TO CONTOURS AND SPOT ELEVATIONS SHOWN ON PLANS. 6.2.5 AT TIME OF PLANTING, ALL AREAS TO BE PLANTED OR SEEDED SHALL BE FREE OF STONES, STUMPS, ROOTS OR OTHER DELETERIOUS MATTER 1' IN DIAMETER OR LARGER AND SHALL BE FREE FROM ALL WIRE, PLASTER, OR SIMILAR OBJECTS THAT WOULD BE HINDRANCE TO PLANTING OR MAINTENANCE. 6.2.6 SLOPES STEEPER THAN 3:1 SHALL BE RAKED SMOOTH, BUT SHALL NOT RECEIVE SOIL AMENDMENTS (EXCEPT IN PLANT PITS, IF ANY); UNLESS SPECIFIED ON THE PLANS. 6.3 LANDSCAPE FINISH GRADING: 6.3.1 FINISH GRADING AFTER SOIL PREPARATION SHALL ESTABLISH FINAL FLOW LINES AND GRADIENTS FOR UNIFORM WATER DRAINAGE. FLOWLINES AND GRADIENTS SHALL BE ESTABLISHED FROM THE HIGH POINT TO THE DRAINAGE OUTLET OR AN INLET STRUCTURE. 6.3.2 FINISH GRADE FOR ALL LAWN AREAS SHALL BE 1' BELOW SIDEWALKS AND CURBS, EXCEPT AT LOCATIONS THAT DRAINAGE WATER WILL FLOW ONTO OR ACROSS HARDSCAPE, CURBS OR PAVING. AT THESE CONDITIONS, THE GRADE SHALL BE FLUSH OR NOT MORE THAN 1/4' BELOW HARDSCAPING. FINISHED GRADES SHALL BE OF UNIFORM SLOPE AND GRADE BETWEEN POINTS OF FIXED ELEVATIONS OR ELEVATION CONTROLS, AND FROM SUCH POINTS ESTABLISH GRADES. 6.3.3 ALL FINISH GRADES SHALL BE FLOATED TO ASSURE A UNIFORM SURFACE WITHOUT IRREGULAR DIPS OR RIDGES. ALL TURF AREAS SHALL BE FLOATED WITH A MINIMUM 4' WIDE FLOAT AND GRADED AWAY FROM THE ESTABLISHED FLOWLINE. ROLL ALL PROPOSED TURF AREAS AND REFLOAT TO ELIMINATE DEPRESSIONS. 6.3.4 CONTRACTOR SHALL BE RESPONSIBLE FOR BRINGING ALL PLANTING AREAS TO FINISH GRADE AFTER SOIL PREPARATION WHICH SHALL BE 1' BELOW PAVING AND CURBS OR AS NOTED BY SPOT ELEVATIONS. SPECIAL ATTENTION SHALL BE GIVEN TO MAINTAINING CONTINUOUS AND EVEN FLOWLINES, AND DRAINAGE AWAY FROM STRUCTURES, TO DRAIN INLET OR OUTLETS. GRADES SHALL BE ESTABLISHED TO DRAIN ALL WATER AWAY FROM STRUCTURES BEHIND WALLS. WHEN DRAINAGE IS DIFFICULT TO ACHIEVE, THE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT AND REQUEST A SOLUTION BEFORE CONTINUING. GRADE IN SHRUB AREAS SHALL BE ESTABLISHED PRIOR TO PLANTING TO ENSURE PROPER FINAL PLANTING HEIGHTS. 6.3.5 ALL FILL AREAS AND CONSTRUCTED BERMS OR MOUNDS SHALL BE COMPACTED IN EVEN LEVELS TO A MAXIMUM COMPACTION OF 80%. 6.4 SPACING: WHEN PLANT MATERIAL IS SPACED IN ROWS, THE TOTAL DIMENSION SHALL BE VERIFIED AND THE PLANTS EQUALLY SPACED WITHIN THE DESIGNATED AREA. WHEN PLANT MATERIAL IS SHOWN IN A LOOSE PATTERN, THE CONTRACTOR SHALL SPACE THE MATERIAL AS SHOWN ON PLANS OR AS DIRECTED BY LANDSCAPE ARCHITECT. GROUND COVER MATERIAL SHALL BE TRIANGULARLY SPACED PER DIMENSIONS INDICTED ON PLANS (WHERE APPLICABLE). 6.5 PLANT PITS: PLANT PITS SHALL BE DUG WITH LEVEL BOTTOMS WITH WIDTHS AND DEPTHS AS SHOWN IN DETAIL DRAWINGS. PITS FOR TREES SHALL BE DUG SQUARE. FILL PITS WITH WATER AND ALLOW TO DRAIN OUT. PLANT HOLES DUG BY AUGER METHOD WILL BE ACCEPTABLE, BUT SHALL HAVE SIDE WALL ROUGHENED OR SQUARED WITH A SHOVEL. SLICK PIT WALLS CAUSED BY AUGERING IN TOO WET SOIL WILL NOT BE ACCEPTED FOR PLANTING. 6.6 REMOVAL FROM PLASTIC CONTAINERS: ALL CONTAINER STOCK SHALL BE REMOVED FROM CONTAINER IN SUCH A WAY AS TO NOT DISTURB THE ROOT BALL. TAP CONTAINER AROUND ALL SIDES AND BOTTOM TO LOOSEN SOIL FROM CONTAINER. TURN CONTAINER UPSIDE DOWN AND CAREFULLY SLIDE OUT WITHOUT PULLING ON THE PLANT STEM OR TRUNK. ROOT BALL SHALL BE SUFFICIENTLY MOIST TO PREVENT DISTURBANCE OF ROOTS UPON REMOVAL OF THE CONTAINER. 6.7 HANDLING: NO PLANT MATERIAL SHALL BE PLANTED IF THE BALL IS BROKEN OR CRACKED EITHER BEFORE OR DURING THE PROCESS OF PLANTING. 6.6 SETTING: PLANTS SHALL BEAR SAME RELATION TO SOIL LEVEL WHEN PLANTED AS THEY DID WHEN IN CONTAINER. EACH PLANT SHALL BE PLACED IN CENTER OF PLANT PIT. NO PLANTING SHALL OCCUR DURING WEATHER CONDITIONS WHICH ADVERSELY AFFECT PLANT MATERIAL OR WHEN SOIL IS IN A MUDDY CONDITION. 6.9 PIT BACKFILL PROCEDURE: 6.9.1 PLACE AGRIFORM 21 GRAM PLANT TABLETS IN BOTTOM OF PLANT PITS, ADHERING TO THE PLANTING NOTES. 6.9.2 BACKFILL PIT WITH BACKFILL MIX HALF-WAY TO FINISH GRADE AND WATER THOROUGHLY. 6.9.3 BACKFILL TO FINISH GRADE. BACKFILL MIX SHALL BE TAMPED FIRM, AND A SHALLOW BASIN FORMED AT PERIMETER OF PLANT PIT TO HOLD ENOUGH WATER TO SATURATE THE ROOT BALL AND BACKFILL MIX. 6.9.4 WATER IMMEDIATELY TO SATURATE ENTIRE ROOT BALL AND BACKFILL. 6.9.5 REMOVE WATERING BASINS PRIOR TO HYDROSEEDING (IN LAWN AREAS ONLY). 6.10 TREE STAKING: STAKE ALL TREES AS SHOWN IN DETAILS. DRIVE STAKES INTO FIRM SOIL NEXT TO ROOT BALL AND BACKFILL WITH PREPARED SOIL MIX. TREE AND STAKES SHALL BE VERTICAL IN ALL CASES. ONE GALLON AND LINER TREES SHALL BE PLANTED WITH STAKE REMOVED, UNLESS OTHERWISE DIRECTED. 6.11 FLATTED GROUND COVER: 6.11.1 ROOTED CUTTINGS SHALL BE PLANTED SUFFICIENTLY DEEP TO COVER ALL ROOTS AND SPACED AS SPECIFIED ON LANDSCAPE PLAN. 6.11.2 GROUND COVER PLANTS (ROOTED CUTTINGS) SHALL HAVE BEEN GROWN IN FLATS AND SHALL REMAIN IN THOSE FLATS UNTIL TIME FOR TRANSPLANTING. AT TIME OF TRANSPLANTING, THE FLAT SOIL SHALL CONTAIN SUFFICIENT MOISTURE SO THAT THE SOIL DOES NOT FALL APART WHEN LIFTING PLANST FROM FLAT. EACH PLANT SHALL BE PLANTED WITH ITS PROPORTIONATE AMOUNT OF THE FLAT SOIL IN A MANNER THAT WILL ENSURE A MINIMUM OF DISTURBANCE TO THE ROOT SYSTEM. 6.11.3 ROOTED CUTTINGS SHALL NOT BE ALLOWED TO DRY OUT BEFORE OR WHILE BEING PLANTED. WILTED PLANTS SHALL NOT BE ACCEPTED. 6.11.4 AT TIME OF PLANTING ALL GROUND COVER PLANTS, THE EARTH AROUND EACH PLANT SHALL BE FIRMED SUFFICIENTLY TO FORCE OUT ALL AIR POCKETS. 6.11.5 EACH GROUND COVER PLANT SHALL BE PLANTED WITH A MINIMUM OF ONE 5 GRAM 20-15-5 PLANT TABLET ADJACENT TO ROOT ZONE. 6.12 MULCHING: WHEN PLANTING OPERATIONS ARE COMPLETE AND SHRUB AREAS HAVE BEEN RAKED AND DRESSED, MULCH ALL SHRUB AND TREE WATERING BASINS WITH A 1" LAYER OF GROUND FIR BARK (0 • 1/4' SIZE). DO NOT MULCH PLANTED GROUND COVER AREAS PRIOR TO PLANTING GROUND COVER OR HYDROSEEDING. DO NOT MULCH TREES IN TURF AREAS. ALL NON-TURF PLANTING AREAS LESS STEEP THAN 3:1 SHALL RECEIVE A 3' THICK LAYER OF MULCH. SUBMIT SAMPLE TO CITY INSPECTOR FOR APPROVAL PRIOR TO BULK DELIVERY TO THE JOB SITE. 6.13 QUANmlES: IN ALL CASES, QUANTITIES OF PLANT MATERIAL SHALL BE FURNISHED AS NEEDED TO COMPLETE WORK AS INDICATED ON DRAWINGS, INCLUDING RESEEDING, REDRESSING, AND MAINTENANCE (REPLACEMENTS) DURING THE CONTRACT PERIOD. 6.14 PROTECTION: THE CONTRACTOR SHALL CAREFULLY AND CONTINUOUSLY PROTECT ALL AREAS INCLUDED IN THE CONTRACT, INCLUDING LAWN AREAS, PLANT MATERIALS, SUPPORTERS, ETC., UNTIL FINAL ACCEPTANCE OF THE WORK BY THE OWNER OR HIS REPRESENTATIVE. 6.15 CLEAN-UP: AFTER ALL PLANTING OPERATIONS ARE COMPLETED, CONTRACTOR SHALL REMOVE ALL TRASH, EXCESS SOIL, EMPTY PLANT CONTAINERS, OR OTHER ACCUMULATED DEBRIS FROM THE SITE AT NO EXTRA COST TO OWNER. CONTRACTOR SHALL REPAIR ALL SCARS, RUTS, OR MARS IN AREA CAUSED BY WORK OPERATIONS. AREAS SHALL BE LEFT IN A NEAT AND ORDERLY CONDITIONS. 6.16 INSPECTIONS (PLANTING PHASE): 6.16.1 CONTRACTOR SHALL GIVE FORTY-EIGHT HOURS NOTICE AND SET APPOINTMENT FOR ALL REVIEWS BY THE LANDSCAPE ARCHITECT. 6.16.2 REVIEW BY OWNER AND LANDSCAPE ARCHITECT AND CITY INSPECTOR SHALL BE SCHEDULED FOR THE FOLLOWING OPERATIONS: A REVIEW OF FINISH GRADING B. REVIEW OF ALL PLANT MATERIAL PRIOR TO PLANTING. C. TREE AND SHRUB PLACEMENT PRIOR TO DIGGING HOLES. D. REVIEW OF GROUND COVER LINES AND MOW CURB PRIOR TO PLANTING. E. START OF MAINTENANCE PERIOD/ACCEPTANCE OF INSTALLATION. F. FINAL ACCEPTANCE AT END OF MAINTENANCE PERIOD. 6.16.3 REVIEW SHALL BE CALLED FORA TEND OF ALL PLANTING OPERATIONS FOR THE PURPOSE OF DETERMINING COMPLIANCE WITH PLANS AND SPECIFICATIONS, INTENT, WORKMANSHIP, AND CLEAN-UP. CONTRACTOR SHALL SECURE WRITTEN VERIFICATION OF REVIEW DATA, ANY CORRECTIONS REQUIRED TO WORK, AND LIMITS OF REVIEWED AREAS BEFORE BEGINNING THE DESCRIBED ESTABLISHED WORK. 6.16.4 IN THE EVENT THE CONTRACTOR REQUESTS INSPECTION OF WORK, AND SAID WORK IS SUBSTANTIALLY INCOMPLETE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OWNER'S COSTS. 6.17 OMIT 6.16 GUARANTEE: 6.18.1 ALL SHRUBS, GROUND COVERS, AND LAWN AREAS SHALL BE GUARANTEED AS TO GROWTH AND HEAL TH OF A PERIOD OF NINETY DAYS AFTER FINAL ACCEPTANCE BY THE OWNER OR HIS REPRESENTATIVE; ALL TREES SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR. 6.18.2 PLANTS WHICH DIE OR LOSE MORE THAN 30% OF THEIR ORIGINAL LEAVES SHALL BE REPLACED UNDER THIS SECTION. 6.18.3 THE CONTRACTOR, WITHIN FOURTEEN DAYS OF WRITTEN NOTIFICATION BY OWNER, SHALL REMOVE AND REPLACE ALL GUARANTEED PLANT MATERIALS WHICH FOR ANY REASON FAIL TO MEET THE REQUIREMENTS OF THE GUARANTEE. ALL PLANT MATERIAL REPLACED SHALL BE GUARANTEED FOR THE ORIGINAL PERIOD, STARTING FROM THE DATE OF REPLACEMENT. 6.19 ESTABLISHMENT PERIOD: 6.19.1 CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ALL AREAS INCLUDED IN THE CONTRACT DURING THE PROGRESS OF THE WORK, THROUGH THE ESTABLISHMENT PERIOD, AND UNTIL FINAL ACCEPTANCE OF THE WORK. 6.19.2 THE ENTIRE PROJECT SHALL BE MAINTAINED IN A SATISFACTORY CONDITION FOR A PERIOD OF NINETY CALENDAR DAYS, COMMENCING FROM THE TIME ALL ITEMS OF IRRIGATION AND LANDSCAPE PLANTING WORK HAVE BEEN COMPLETED AS SPECIFIED IN THE FOREGOING ARTICLES OF THESE SPECIAL PROVISIONS TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT, AND UPON THOROUGH GERMINATION OF THE HYDROSEED AREAS AS DETERMINED BY THE LANDSCAPE ARCHITECT. 6.19.3 ESTABLISHMENT WORK INCLUDES ALL MOWING, WATERING, WEEDING, RESEEDING, MULCHING, CULTIVATING, SPRAYING, AND TRIMMING NECESSARY TO BRING THE PLANTED AREAS TO A HEAL THY GROWING CONDITION, AND ANY ADDITIONAL WORK NEEDED TO KEEP THE AREAS NEAT, EDGED, AND ATTRACTIVE. 6.19.4 WATER GRASS UNTIL ACCEPTANCE OF WORK. THE AREAS SHALL BE KEPT MOIST, BUT NOT GLISTENING WET, UNTIL TIME FOR THE FIRST CUTTING OF GRASS. AFTER FIRST CUTTING, WATER LAWN TO MAINTAIN A THRIVING CONDITION. RESEEDED AREAS THAT DO NOT SHOW PROMPT MAINTAIN THE LAWN AREAS UNTIL AN EVEN, CLOSE STAND OF GRASS HAS BEEN OBTAINED AND FOR AT LEAST THIRTY DAYS. 6.19.5 DURING THE PLANT ESTABLISHMENT PERIOD, ALL PLANTS AND PLANTED AREAS SHALL BE KEPT WELL WEED-FREE AT ALL TIMES. WEEDS, DALLAS AND JOHNSON GRASS, AND BERMUDA GRASS SHALL BE REMOVED AND DISPOSED OF. PAY SPECIAL ATTENTION TO WATERING SLOPES PLANTED IN LAWN ON THE WINDWARD AND/OR SUNNY SIDE SO THAT LAWN WILL BE ADEQUATELY WATERED AT ALL TIMES. 6.19.6 THE LAWNS SHOULD BE EDGED WHENEVER NECESSARY. THE GRASS SHALL BE MOWED WITH SHARP AND ADJUSTED MOWERS BEFORE IT EXCEEDS 2" IN HEIGHT. THE GRASS WILL BE CUT TO NOT LESS THAN 1", AND DURING THE PERIOD OF MAINTENANCE, THE GRASS WILL NOT BE ALLOWED TO EXCEED 2" IN HEIGHT. 6.19.7 IMMEDIATELY AFTER THE FIRST CUTTING OF GRASS, WHEREVER A LAWN AREAS IS BOUNDED BY TREES OR SHRUBS, THE EDGE OF THE GRASS SHALL BE TRIMMED TO A NEAT AND UNIFORM LINE AT A DISTANCE OF APPROXIMATELY 'Z FROM THE TREES OR SHRUBS. WHERE MOW CURB EXISTS, TRIM TO MOW CURB. WHERE TREES OR SHRUBS OCCUR IN GRASS AREAS, THE GRASS SHALL BE TURNED UNDER AND NEATLY EDGED 18' AWAY FROM THE PLANTS. THE LAWN EDGES SHALL BE MAINTAINED A NEAT CONDITION UNTIL ACCEPTANCE OF THE WORK. 6.19.8 WORKMEN SHALL NOT BE ALLOWED TO WORK ON GRASS AREAS UNNECESSARILY BEFORE, DURING, AND AFTER SEEDING OPERATIONS. GRASS AREAS THAT HAVE BEEN DAMAGED OR COMPACTED SHALL BE RECULTIVATED AND RESEEDED AT THE CONTRACTOR'S EXPENSE. 6.19.9 ANY DAY THE CONTRACTOR FAILS TO ADEQUATELY WATER, REPLACE UNSUITABLE PLANTS, WEEDS, AND OTHER WORK DETERMINED TO BE NECESSARY BY THE OWNER, WILL NOT BE CREDITED AS PART OF THE ESTABLISHMENT PERIOD. 6.19.10 DURING THE ESTABLISHMENT PERIOD, ANY PLANT INDICATING WEAKNESS OR PROBABILITY OF DYING, SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE. 6.19.11 ALL BASINS AROUND SHRUBS AND TREES SHALL BE MAINTAINED AT A FOUR INCH DEPTH THROUGHOUT ESTABLISHMENT PERIOD, UNLESS OTHERWISE INSTRUCTED BY THE OWNER OR HIS REPRESENTATIVE. 6.19.12 TREE STAKES WHICH FOR ANY REASON ARE DAMAGED OR RENDERED INADEQUATE FOR SUPPORT SHALL BE REPAIRED AND RESTORED TO THEIR ORIGINAL CONDITION. 6.19.13 CONSTANT DILIGENCE SHALL BE MAINTAINED TO DETECT THE PRESENCE OF DISEASE, INSECTS, AND/OR RODENT INFESTATIONS AND PROPER PREVENTATIVE OR CONTROL MEASURES TAKEN. 6.19.14 ALL SHRUBS AND TREES SHALL BE MAINTAINED IN THEIR NATURAL SHAPES. TALL OR SCRAGGLY BRANCHES SHALL BE TINNED OUT WHERE NECESSARY. IN NO CASE SHALL TREES OR SHRUBS BE TRIMMED BY HEADING OR SHEARING. ANY PLANTS SEVERELY PRUNED IN THIS MANNER SHALL BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. 6.19.15 ON THE 45TH DAY OF THE ESTABLISHMENT PERIOD, ALL LAWN AREAS SHALL RECEIVE TOP DRESSING OF 6 POUNDS OF 1~ COMMERCIAL FERTILIZER PER 1,000 SQ. FT. 6.19.16 ON THE 80TH DAY OF THE ESTABLISHMENT PERIOD, ALL LAWN AND GROUND COVER AREAS SHALL RECEIVE TOP DRESSING OF 6 POUNDS OF 1~ COMMERCIAL FERTILIZER PER 1,000 SQ. FT. 6.19.17 AT COMPLETION OF ESTABLISHMENT PERIOD, ALL AREAS INCLUDED IN THE CONTRACT SHALL BE SUBSTANTIALLY CLEAN AND FREE OF DEBRIS AND WEEDS. ALL PLANT MATERIALS SHALL BE LIVE, HEALTHY AND FREE OF INFESTATIONS. 6.19.18 ANY EROSION OR SLIPPAGE OF SOIL CAUSED BY WATERING SHALL BE REPAIRED BY THE CONTRACTOR AT HIS EXPENSE. 6.19.19 ALL WALKS, CURBS, AND GUTTERS SHALL BE KEPT CLEAR OF DEBRIS, MUD, DUST, AND STANDING WATER BY SWEEPING, MOPPING, OR HOSING DOWN AS REQUIRED TO MAINTAIN CLEANLINESS THROUGHOUT. 6.20 WRITTEN NOTICE: AT THE END OF SPECIFIED ESTABLISHMENT PERIOD, THE CONTRACTOR SHALL REQUEST FINAL INSPECTION BY LANDSCAPE ARCHITECT FOR FINAL ACCEPTANCE. ALL ITEMS OF MAINTENANCE ESTABLISHMENT PERIOD AND SPECIFICATIONS ARE SUBJECT TO FINAL APPROVAL BY THE OWNER. AFTER FINAL ACCEPTANCE IS GRANTED, CONTRACTOR SHALL PRESENT WRITTEN NOTICE TO THE OWNER THAT HE HAS COMPLETED THE REQUIRED MAINTENANCE, AND THAT ANY FURTHER MAINTENANCE WILL BE THE RESPONSIBILITY OF THE OWNER. END OF SECTION SECTION 7 • CITY OF CARLSBAD LANDSCAPE MANUAL SLOPE REVEGETATION/EROSION CONTROL POLICIES AND REQUIREMENTS A SLOPE PLANTING 1. AREAS OF APPLICATION (PLANTING) -SLOPES6:1 ORSTEEPERAND: -3 FEET OR LESS IN VERTICAL HEIGHT AND ADJACENT TO PUBLIC WALKS OR STREETS REQUIRING A MINIMUM STANDARD #1 (COVER CROP OR EROSION CONTROL MATTING). -GREATER THAN 3 FEET TO 8 FEET IN VERTICAL HEIGHT REQUIRES STANDARD #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP), #2 AND #3 -IN EXCESS OF 8 FEET IN VERTICAL HEIGHT REQUIRE STANDARDS #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP) #2, #3 and #4. • AREAS GRADED FLATTER THAN 6:1 REQUIRE A COVER CROP PER STANDARD #1 WHEN THEY HAVE ONE OR MORE OF THE FOLLOWING CONDITIONS: -SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. -A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY. -IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. 2. SLOPE PLANTING STANDARDS. SLOPES REQUIRING EROSION CONTROL MEASURES, AS SPECIFIED ABOVE, SHALL BE TREATED WITH ONE OR MORE OF THE FOLLOWING PLANTING STANDARDS: • STANDARD #1 • COVER CROP/ AND EROSION CONTROL MATTING -COVER CROP SHALL BE A SEED MIX TYPICALLY COMPOSED OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS AND/OR WILD FLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. -THE COVER CROP SHALL BE APPLIED AT A RATE AND MANNER SUFFICIENT TO PROVIDE NINETY (90%) PERCENT COVERAGE WITHIN 30 DAYS. -TYPE OF EROSION CONTROL MATTING SHALL BE AS APPROVED BY THE CITY AND AFFIXED TO THE SLOPE AS RECOMMENDED BY THE MANUFACTURER. -ON SLOPES GREATER THAN 3 FEET IN HEIGHT, EROSION CONTROL MATTING SHALL BE REQUIRED AND A COVER SHALL NOT BE USED, UNLESS OTHERWISE APPROVED BY THE CITY. STANDARD #2 • GROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE YEAR). STANDARD #3 -LOW SHRUBS LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM OF 2-3/4 INCH LINERS) SHALL COVER A MINIMUM OF SEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE). STANDARD #4 -TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS) AT A MINIMUM RATE OF ONE (1) PER TWO HUNDRED SQUARE FEET. PLANT MATERIALS USED ON SLOPES SHALL BE THOSE SPECIES THAT ARE KNOWN TO HAVE LOW WATER REQUIREMENTS AND ROOTING SYSTEMS OF VARIOUS DEPTHS THAT WILL MINIMIZE EROSION AND SOIL SLIPPAGE. 4. HYDROSEED HYDROSEED IN LIEU OF STANDARD #2 MAY BE ALLOWED IF APPROVED BY THE CITY AND UNDER THE FOLLOWING CONDITIONS: -NATIVE PLANTS ARE REQUIRED TO BE PLANTED AS A CONDITION OF APPROVAL OF THE PROJECT BY THE CITY OR OTHER PRESIDING AGENCY AND THE REQUIRED SPECIES ARE COMMERCIALLY UNAVAILABLE IN CONTAINER OR FLATTED STOCK. • THE SLOPE IS DETERMINED BY THE CITY TO BE TOO ROCKY FOR HAND PLANTING. THE HYDROSEED MIX SHALL CONSIST OF A VARIETY OF LONG LIVED PLANT MATERIALS WITH ROOT SYSTEMS OF VARYING DEPTH. 5. ROCKY SLOPES PLANTING IS NOT REQUIRED FOR: -CUT SLOPES THAT ARE DETERMINED BY THE CITY ENGINEER TO BE ROCKY IN CHARCTER AND NOT SUBJECT TO DAMAGE BY EROSION. • ANY ROCKY SLOPES THAT ARE PROTECTED AGAINST EROSION DAMAGE BY OTHER METHODS THAT HAVE BEEN SPECIFICALLY RECOMMENDED BY A SOILS ENGINEER, ENGINEERING GEOLOGIST, OR EQUIVALENT AUTHORITY AND FOUND TO OFFER EROSION PROTECTION EQUAL TO THAT PROVIDED BY THE PLANTING SPECIFIED IN THIS SECTION AND THEY ARE APPROVED BY THE CITY ENGINEER. APPROVED FOR PLANTING TITLE DATE, 08/25/2016 DRAl"lN BY, EP /HH AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. REVIEWED BY: "AS BU I LT" DATE 1----t--1--------------1----1--_j_ _ _j_ _ _J u[j CITY P9!iNGC~~lSBAD W£J rla 2681 :":HOWARD:\,:: , ASSOCIATES" , "' ,, ~' landscape architecture 2442 second avenue san diego ca 92101 619 718 9660 DATE INrTIAL ENGINEER OF WORK REVISION ' DATE INITLIIL DATE INITIAL DESCRIPTION OTHER APPROVAL CnY APPROVAL PLANTING SPECIFICATIONS FOR: QUARRY CR££K PA R-3 MODELS I APPROVED ~l ~-~\_,3t rz.-,. ( '<> I 'I PLANNING DATE DWN BY: PROJECT NO. DRAWING NO. CHKD BY: CT 15-05 484-5U RVWD BY: