Loading...
HomeMy WebLinkAboutSDP 98-06A; HOEHN SPRINTER; Site PlanCAR COUNTRY DRIVE -----------------I ~---__ 16DISPLAYSPACE~ ------------------------------------------------------------------/ \ --------------------------------------- ~ lilJ 9 {/) m ~ "' i?, 9 "' ~ @ f=:j t3 iJ; 'II 1 ~ ~ m I \ PROPERTY LINE 216. 3' 02 11.·1--"-"'-+---"-"'----1 ~:11":--~-"'-+ __ &_"'_---1 -it:1;"\· ~{/) &en 01 1-----+-------l '{/en 16 KEY SITE PLAN Scale; 1" a 30 tt / ?4'-0" ,y / / ) / rno·-r r/[·77 Ii I/ <-E-----<@]>------>) , I I I I I I 08 D •II 0 ,15 D ,15 D 24'-0" ~~: 36 EXISTING DISPLAY SPACES ~.;g ~, :~ ~ ~ ~ 9c] i2 9d 9u1 °cf 96' 8J t i3 1~ t'' 02 ~----1r----t~'lJ---t--t--r-----t--t---;-;cc-;;;--t--t-----t--+-+-+--tJ-------j--{•li~· "i'-'--1--t--,--+1--+-+---1f--+----,-+,,,1,,sc;'cc· -0-,,·,+,,,.+-+-+---lf--+----Jt-+_,,1-!!,fd ;;:;;i 18 SPCS @ 8'-6'' ~j 07 r-----lL_~",<, 1~1 •~ •go '8' 1gu lg'J 1,'<n 11,l~;' 11)J 1/,1 11,s 11,6 'il' 11,: j 'i\' 1go ;', •• " :14' 169 1/0 ::I< D D ~' f------@}---> 6 EXISTIMG DISPLAY SPACES !24 125 120 ,2, 12n I .,JO 132 13:.J U U D D ''W' D U 1'12 1•\3 D D 153'-0" 18 SPCS@ 8'-6" 1,jfj 14/ 1'!8 1'!9 D D D U 159 160 161 1621163 0 0 0 ll n 102'-0" D 12 SPCS @8'-6" 12 EXISTING DISPLAY SPACES 12.-0 151 D D 166 167 D D 17 EXISTING DISPLAY SPACES 144'-6" 17SPCS 8'-6" 114 175 1/6 li'l 178 1/tl 180 0 D D D [J D _D_ Hl1 Hl2 1!.Kl 1&1 D_ 0 D 0 17 EXISTIMG DISPLAY SPACES 1[)2 1£!3 194 I .,__ 19/ 19tl D D ~ 09 D D \99 200 201 D D D °' -0 " "' I l :1:t'f 186 18"/ HJ.~ 1£19 190 191 M": D D DR D D D 'Ii' Wr--+-+-----ll~+---+-t--+-t--+-f-+----l-+----1--t--l-t- i'-200 20~ 206 207 20/l 209 210 211 212 213 214 215 21G 217 218 ~, I) 001 U D U O D n fl D O O D D 0 ! 7'-1 \" 27'-CI' 3 SPC8@9' f" 1r I llr--i J 6 EXISTING CUSTOMER /4-SPACES 117'-0" f', .... ·.· .• ·.•.· .. ·.· /j !EXiSTING BUJL□rtJG I I 26,8!19:~F I . . _/ ~, I Le.~ ,-C .,.C, ----•• ~-.,j EXISTING DRIVE AISLE EXISTING SERVICE BUILDING 18,794 SF.· [ fl 15J'.Q" 24'-0" ") ,.,_\•;.",;: 108'-0" n D D 12 SPCS@ 8'-6" D 14 D 13 u 12 D "-18 SPCS@ 8'-6" ·., ~ -....____ -----18 EXISTING DISPLA'( SPACES. ----~i<-----t---------ill..-.:.l!=c==.6.==ce!!Sc====""=====ec.==..f1.__r.Ja=· =;l.;=='"-=-=--"'=----"'-'=--e'-:=...=..!'=$,:'E!:'=.c'_,:_=_=_;;;,c=d-~=1_~..:'_:''_!'"l,__~'=._::':..::..:'_!!':_=-.':..=_"-_=~::_':_··=-~ _=_=~.":::::=_= _" -===~===,~ 38 E 30 E 44 .JO E 47 E S 22 29' 22" E -;<----------~10~0~·-~•-· ---------~,r--------------'-13~5~·-~a_· _____________ k,.... __________ 10_,_·._s_·· ----------11'10·-0'* GENERAL NOTES: SITE PLAN KEYNOTES SITE PLAN LEGEND 01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 13. 14. 15. 16. 17. NOT USED. NOT USED. DRAWINGS FOR FIRE HYDRANTS, NEWAND RELOCATED WHERE AND IF REQUIRED, SHALL BE REVIEWED AMO APPROVED BY THE LOCAL FIRE DEPARTMENT FOR APPROVAL. FIRE SPRINKLER DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE LOCAL FIRE DEPARTMENT. DESIGN TO BE BY INSTALLER. NOT USED. ALL REQUIRED PARKING SPACES SHALL BE STRIPPED IN ACCORDANCE WITH THE LOCAL JURISDICTION STANDARDS. FIRE LANES WHERE REQUIRED, SHALL BE CONTINUOUSLY PAVED TO ACCOMODATE 75,000 POUNDS. FIRE LANES \JI/HERE REQUIRED, SHALL HAVE A MINIMUM VERTICAL CLEARANCE OF 13'-6" SITE DRAINAGE SHALL NOT FLOW ACROSS PEDESTRIAN WALKWAYS. ALL DIMEMSIONS ARE TO BE TO FACE OF FINISH SURFACE, FACE OF CONCRETE, CURB, PROPERTY LINE OR CENTERLINE OF PARKl~IG STALL UNLESS OTHER\/IJ1.SE NOTED. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDl~IG. ALL UTILITIES ARE EXISTING AND TO REMAIN, CONTRACTOR TO FIELD VERIFY ACTUAL UTILITY LOCATIOMS. cmJCRETE WALKS SHALL RECEIVE EXPAMSION JOINTS AT I5'-0" o.c. MAXIMUM AND CONTROL JOINTS AT 5'-0" o.c. BETV"JEEM EXPANSION JOINTS UNLESS NOTED OTHERWISE. CONSTRUCTION DUST CONTROL DURl~IG CONSTRUCTIOM DUST CONTROL MEASURES SHALL BE REQUIRED. GRADING WILL BE DISCONTINUED DURING FIRST-STAGE SMOG ALERTS AMO SUSPENDED DURING PERIODS Of HIGH WINDS, (I.E. OVER 15 MILES PER HOUR) ALL HAULING TRUCKS SHALL HAVE LOADS COVERED OR WETTED AND LOADED BELOW THE SIDEBOARDS TO MIMIMIZE DUST. DEMOLITION OF ASBESTOS CONTAINING CONSTRUCTION MATERIALS (ACCM) OR, ASBESTOS CONT AIMING BUILDING MATERIALS (ACBM) IN THE BUILDING OR ANY OTHER STRUCTURES SHALL BE IN STRICT ACCORDANCE TO THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULES. GENERAL CONTRACTOR SHALL OBTAINED PERMJTS FROM THE STATE DIVISION OF JNDUSTRIAL SAFETY FOR ANY WORKJN TRENCHES OR EXCAVATIONS 5'-0" OR DEEPER. ALL FOUNDATION DESIGN, FOUNDATION PLANS AND DETAILS SHALL BE REVIEWED AND APPROVED BY THE SOILS ENGINEER. @I] ~. 03. 04. D5. 06. 07. 06. 09. 10. 11. 12. 13. 14. 15. 16. PROPERW LINE. EXISTING LANDSCAPED AREA TO REMAIN, PROTECT IN PLACE. EXISTING SIDEWALK AND PEDESTRIAN PATH OF TRAVEL. EXISTING COMCRETE DRIVE APPROACH TO REMAIN. EXISTING SIGN TO REMAIN, EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING PLANTER, PROTECT IN PLACE. NEW SIGN. INTERNALLY ILLUMINATED, ALL SIGNAGE TO BE U~IDER A SEPARATE PERMJT. SIGN PACKAGE TO BE SUBMITTED TO THE CITY FOR APPROVAL BY THE SIGN VENDOR. INVEMTORY ANO DISPLAY PARKING. CUSTOMER PARKING HANDICAP PARKIMG SPACES. EXISTING COMCRETE AREAS. EXISTING MASONRY WALL TO REMAIN. EXISTING UTILITY EASEMENT. EXISTING EMPLOYEE PARKING. EXISTING NOM CONFORMING 24'-0" WIDE FIRE LANE OPEM TO SKY. EXISTING CONCRETE DRIVE, FIRE DEPARTMENT TO REVIEW AND APPROVE FIRE LANE LOCATION AND DIMENSIONS DURING PLAN CHECK REVIEW PROCESS FOR COMPLIANCE. EXISTING AC PAVING AREAS. EXISTING BUILDINGS PROPOSED SPRINTER SERVICE BUILDING EXISTING CONCRETE EXISTlt-lG LANDSCAPED AREAS '1> '° @ 19 (I) •r w mu ~ "-"' ~l NOTES: 1. ALL PROPERTY LINES, EASEMENTS AND BUILDINGS BOTH EXISTING AND PROPOSED, ARE SHOWN ON THIS SITE PLAN. 2. FOR ADDITIONS TO PROJECTS Of OME ACRE OR LESS THE SJTE SHALL BE PLANNEDNID DEVELOPED TO KEEP SURFACE WATER AWAY FROM BUILDIMGS, A "SWPP" SHALL BE PROVIDED AND APPROVED BY THE CITY EMGINEER, SHOWING SITE GRADIMG AND PROVIDE FRO STORM '.NATER RETENTION SMF DRAINAGE DURING CONSTRUCTION. BMP'S THAT ARE CURRENTLY ENFORCED B't THE CITY EMGINEER MUST BE IMPLEMENTED PRIOR TO INITIAL IMSPECTION BY THE BUILDIMG DEPARTMEMT. 3. BICYCLE PARKING FOR PROJECTS SHALL COMPLY \11/lTH CGC SECTION 5.710.6.2 FOR ADDITIONS. THE SPECIFIC DETAILS MUST BE SUBMITTED AND APPROVED BY THE PLANNING DEPARTMENT. 4. FUEL EFFICIENT VEHICLE PARKING WILL BE PROVIDED IN ACCORDANCE VVlTH CGC SECTION 5.710.6.3 FOR ADDITIOMS. THE SPECIFIC DETAILS MUST BE SUBMITTED AND APPROVED BY THE PLANNING DEPARTMENT. 5. GENERAL CONTRACTOR TO SUBMIT TO THE ENGINEERING DEPARTMENT OR OTHER CITY AGENCY THAT REGULATES CONSTRUCTION WASTE MA/'IAGEMENT A WASTE MANAGEMENT PLAN THAT OUTLIMES ITEMS LISTED IN CGC SECTION 5.713.8.1.1 6. A MINIMUM OF 5% OF NONHAZARDOUS CONSTRUCTION WASTE IS TO BE RECYCLED TO COMPLY WlTH CGC 5.713.8.1 7. TESTING AMO ADJUSTING Of NEW SYSTEMS AS OUTLIMED IN CGC SECTION 5.713.10.4.2 8. A "BUILDING OPERATIONS AND MAINTEMANCE SCHEDULE" (0 & M) AS LISTED IN CGC SECTION 5.7·1 J.10.4.5 SHALL BE DELIVERED TO THE BUILDING OW~IER OR REPRESENTATIVE AND THE FACILITIES OPERATOR BY THE GEMERAL CONTRACTOR. 9. voe MUST COMPLY WITH THE LIMITATIONS LISTED IM SECTION 5.504.4AND TABLES 4.504.1, 5.504.4.1, 504.4.2, 5.504.4.5 FOR; ADHESIVES, SEALANTS, PAINTS AND COATINGS, CARPET AND COMPOSITION WOOD PRODUCTS. CGC 5.714.'!.4. 10. 1NHERE LANDSCAPE IRRIGATION IS PART OF THE ADDITlml OR TENANT IMPROVEMENT, LANDSCAPE IRRIGATION WATER USE SHALL HAVE WEATHER BASED CONTROLLERS. CGC 5.712.4.3.1 APPROVED TWS IS THE Al'l'ROVED TENTATIVE MAl'ISITE PLAN FORI'ROJECT NO. /? PER CONDITION NO. 701..t-, -1/},u,J;\Jw,A-.._.,, ~-Z'l-!~ (Jt4 r,1.u :-Jl..'IG IJIVISlON IJ,\Tli. ~E-Nc--c-,-,'--El=O-N_G_U_I_VJ-,-1u-,A---...j.j=~ 2 DATE DESCRIPTION '2013.11.26 1STPLAN H KSU MITTAL 2014.03.14 2ND PLAN CHECK SUBMITTAL Whitfield Associates/ Inc. 24691 Del Prado, Suite 201, Dana Point. CA 92629 Phone: 9 4 9 . 2 3 4. 1 9 SO www.waarch.com architecture PROJECT TITLE; ■ s.. a, I t: I.. a. en t: .c: a, 0 :::c: SHEET TITLE; planning C) C: ■- ■-:::::, aJ a, 0 ■-c: a, en interior design w > - 0::: C >-co 0::: 8 I-~ z <( ::) 0 u 0::: <( u LO ,-... 'q' LO 0 0 <( co (J) _J er:: <( 0 KEY SITE PLAN PROJECT No ................... 2013-0024 SCALE; NTS DRAWN BY; PLOT DATE; SHEET NUMBER AS