HomeMy WebLinkAboutDWG 489-4L; SDP 15-10; CARLSBAD OAKS NORTH LOT 13; 01-44RECYCLED WATER IRRIGATION LEGEND IRRIGATION EQUIPMENT LEGEND IRRIGATION SPRAY HEAD SPRINKLER LEGEND SYMBOL MANUFACTURE/ MODEL NO. I DESCRIPTION DETAIL SHEET SYMBOL MANUFACTURE/ MODEL NO. I DESCRIPTION DETAIL SHEET SYMBOL QI H F V FLOW RATE GPM PREC. MANUFACTURE I MODEL NO. I DESCRIPTION Q H F V PSI RADIUS RATE DETAIL SHEET ~ RECYCLED WATER SIGNS, INSTALL QUANTITY AND LOCATIONS PER PER THE CARLSBAD EE 20 YARDNEY -SB 2-P. 2" (PURPLE) BASKET STRAINER WITH FLANGED CONNECTIONS AND 80 MESH C 17 SHRUB 12" HI-POP SPRAY HEADS WITH CHECK VALVE AND PRESSURE REGULATION MUNICIPAL WATER DISTRICT AND SAN DIEGO (DEH) WATER RECYCLING REQUIREMENTS. ® FILTER ELEMENT. STRAINER ASS EMBLY SHALL BE INSTALLED WITHIN A VIT STRONG BOX L/RCS SST CST RAIN BIRD -RD-12-S-P30-F-NP, WI 15 STRIP SERIES NOZZLE 4x15 FT SBBC-30CR SMOOTH TOUCH ENCLOSURE INSTALLED ON A POURED IN PLACE CONCRETE PAD. ----.30 .90 ,90 " 30 1.96 A 17 NO SYMBOL AS APPROVED -CONTROLLER SHALL HAVE RECYCLED WATER PLACARD INSTALLED AS REQUIRED. I.I El I!!!] LCS-PCS-030 I RCS-PCS-030 I SST-PCS-060 I CST-PCS-060. 4x30 FT & RECYCLED WATER CROSS CONNECTION TEST STATION. D 17 NO SYMBOL T. CHRISTY'S -(PURPLE) "RECYCLED WATER" VALVE I.D. TAG INSTALL WITHIN EACH VALVE BOX TYP. NOTE: ALL SPRAY AND ROTOR HEAD BODIES SHALL HAVE FACTORY INSTALLED RECLAIMED WATER IDENTIFICATION CAP. IMPERIAL TECHNICAL SERVICES -FSV-200-N, NETAFIM SERIES 2" NORMALLY CLOSED HYDROMETER E 17 NO SYMBOL AS APPROVED -ALL VALVE BOXES SHALL BE (PURPLE) "RECYCLED WATER" AND MARKED AS REQUIRED @ COMBINATION VALVE (MASTER VALVE I FLOW METER) -ENSURE CORRECT OPTIONS ARE INCLUDED FOR RECYCLED WATER USE. FOR OPERATION WITH CONTROLLER ASS EMBLY. IRRIGATION ROTATOR HEAD SPRINKLER LEGEND NOTE: ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE RECLAIMED WATER IRRIGATION SYSTEM REQUIREMENTS SET FOR ® EZ-FLO SYSTEMS -EZ-005-FX-CBV-200, 5 GALLON FERTILIZING SYSTEM. G 17 SYMBOL FLOW RATE GPM PREC. BY SAN DIEGO ENVIRONMENTAL HEALTH AND CITY OF CARLSBAD MUNICIPAL WATER DISTRICTS RULES AND REGULATIONS. Q I H I F MANUFACTURE I MODEL NO./ DESCRIPTION Q H F PSI RADIUS RATE DETAIL SHEET ~ SPEARS -3629-020, TRUE UNION 2000 STANDARD PVC SLIP SLIP BALL VALVE, LINE SIZE. H 17 RAIN BIRD -PESB-NP-HAN-(1" OR 1-112") SERIES PLASTIC, RECYCLED WATER, I, L 18 SHRUB 12" HI-POP ROTATOR HEADS WITH CHECK VALVE AND PRESSURE REGULATION ~ IRRIGATION VIVE BUBBLER LEGEND REMOTE CONTROL VALVE WITH PURPLE HANDLE, SIZE AS SHOWN. ED RAIN BIRD -RD-12-S-P30-F-NP, WI HUNTER ROTATOR SERIES MP .17 --" 30 8-12 FT .45 A 17 CORNER NOZZLE. SYMBOL MANUFACTURE I MODEL NO./ DESCRIPTION GPM PSI RADIUS PREC, DETAIL SHEET l"iil RAIN BIRD -XCZ, (1" OR 1-112") SERIES DRIP VALVE ASSEMBLY WITH PURPLE HANDLE, SIZE AS J, L 18 RATE SHOWN. INSTALL XCZ-PRB-100-COM, 1" VALVE ASSEMBLY FOR DEMANDS (1 -14) GPM. @I ~ ill] RAIN BIRD -RD-12-S-P30-F-NP, WI HUNTER ROTATOR SERIES MP .18 .35 .65 30 8-12 FT .45 A 17 HUNTER -PCB-R25 SERIES PRESSURE COMPENSATING TRICKLE .25 30 NIA 2.7 FF 39 INSTALL XCZ-PRB-150-COM, 1-112" VALVE ASSEMBLY FOR DEMANDS (15 -35) GPM. 1000 NOZZLE. l;;J BUBBLER W/ PURPLE CAP INSTALLED ON 112" PVC SCH. 80 RISER. SIGNATURE -7645, 1" NON-POTABLE, ACME THREAD QUICK COUPLER VALVE WITH PURPLE K, L 18 [zJ Ill] ~ RAIN BIRD -RD-12-S-P30-F-NP, WI HUNTER ROTATOR SERIES MP .33 .63 1,27 30 13-17 FT .45 A 17 PLACE BUBBLER AT EDGE OF VINE ROOTBALL TYPICAL. ® LOCKING COVER FOR RECYCLED WATER USE. 2000 NOZZLE. RAIN BIRD -RD-12-S-P30-F-NP, WI HUNTER ROTATOR SERIES MP l!ID [jJ] IUl .74 1.84 3000 NOZZLE. 3.15 30 19-27 FT .45 A 17 EXISTING RECYCLED WATER IRRIGATION LEGEND IRRIGATION CONTROLLER EQUIPMENT LEGEND ILll IHI RAIN BIRD -RD-12-S-P30-F-NP, WI HUNTER ROTATOR SERIES MP 4x14 FT .45 A 17 MPLCS515 I MPRCS515 / MPSS530 NOZZLE. .19 .19 .38 30 4x28 FT SYMBOL MANUFACTURE I MODEL NO. I DESCRIPTION SYMBOL MANUFACTURE I MODEL NO. I DESCRIPTION DETAIL SHEET @ (EXISTING) 2" RECYCLED WATER IRRIGATION METER WITH 2" SERVICE LINE. VERIFY SIZE, LOCATION, IMPERIAL TECHNICAL SERVICES -ICA6-ETW2-48 I SP I RSE I ETW2SP-5 / ETWFS-51 ETW-UA. M 18 IRRIGATION TREE BUBBLER LEGEND AND STATIC WATER PRESSURE IN FIELD. 0 (ICA6 = STAINLESS STEEL TOP ENTRY PEDESTAL ENCLOSURE, PREC. SYMBOL MANUFACTURE I MODEL NO. I DESCRIPTION GPM PSI RADIUS DETAIL SHEET llll'I (EXISTING) 2" RIP BACKFLOW PREVENTION ASSEMBLY WITH PRESSURE REGULATOR, VERIFY AND TEST FOR ETW2-48 = "ET WATER" 48 STATION CENTRAL COMMUNICATION IRRIGATION CONTROLLER ASSEMBLY, RATE PROPER OPERATION, REPAIR OR REPLACE IF DAMAGED. SP= SURGE PROTECTION, ® RAIN BIRD -RD-06-S-P30-F-NP, WI HUNTER MSBN-250 BUBBLER NOZZLE. .25 (.50) 30 1 FT 1.85 A 17 l&il RSE = RAIN SWITCH, (EXISTING) MASTER VALVE, VERIFY AND TEST FOR PROPER OPERATION, REPAIR OR REPLACE IF DAMAGED. ETW2SP-5 = ET WATER MANAGER SERVICE PLAN -5 YEAR, NOTE: SINGLE SYMBOL ON PLANS REPRESENTS TWO (2) BUBBLERS PER TREE. IE! (EXISTING) FLOW SENSOR, VERIFY Al'-JD TEST FOR PROPER OPERATION, REPAIR OR REPLACE IF DAMAGED. ETWFS-5 = FLOW SENSOR DATA PLAN -5 YEAR, PLACE BUBBLERS AT EDGE OF ROOTBALL ON OPPOSITE SIDES OF TREE TYPICAL. ETW-UA = UNIVERSAL 9 PIN REMOTE CONTROL ADAPTER) (EXISTING) CONTROLLER "L", PROTECT IN PLACE, VERIFY AND TEST FOR PROPER OPERATION. FOR FURTHER INFORMATION CONTACT DARYL GREEN AT GREEN PRODUCT SALES (949) 584-7311. [g REPAIR OR REPLACE IF DAMAGED. VERIFY QUANTITY OF AVAILABLE OPEN STATIONS, REPLACE THE INSTALLATION OF CONTROLLER MUST BE APPROVED AND CERTIFIED BY IMPERIAL TECHNICAL IRRIGATION ROTOR HEAD SPRINKLER LEGEND SERVICES. PROVIDE COPIES OF CERTIFICATION TO THE OWNER'S AUTHORIZED REPRESENTATIVE AND CONTROLLER IF INADEQUATE NUMBER OF OPEN STATION EXIST. LANDSCAPE ARCHITECT. SYMBOL FLOW RATE GPM PREC. ----:JE---DI H I F MANUFACTURE I MODEL NO./ DESCRIPTION Q H F PSI RADIUS RATE DETAIL SHEET CONNECTION OF NEW MAINLINE TO EXISTING MAINLINE, VERIFY SIZE, LOCATION AND CONNECTION POINTS IN FIELD. IMPERIAL TECHNICAL SERVICES -RAIN SENSOR, MOUNTED TO SIDE OF ENCLOSURE AND WIRE TO M 18 0----CUT AND CAP EXISTING MAINLINE, VERIFY EXACT LOCATION IN FIELD. lll:il CONTROLLER INSTALLED WITHIN STAINLESS STEEL VANDAL RESISTANT ENCLOSURE. RAIN SENSOR 12" POP-UP ROTOR HEAD WITH CHECK VALVE AND PRESSURE REGULATION IS SUPPLIED AS PART OF JOHN DEERE ASSEMBLY. (1) ~ ~ HUNTER -PGP-12-CV-R, ULTRA SERIES, 12" POP-UP SHRUB .43 .90 1.7 35 16 FT 0.46 A 17 +---(EXISTING) IRRIGATION MAINLINE SHOWN FOR REFERENCE ONLY. PROTECT IN PLACE, REPAIR ANY DAMAGE ROTOR HEAD WI NOZZLES Q-.50SRIH-1.0SR/F-2.0SR DUE TO CONSTRUCTION. VERIFY SIZE, TYPE, AND EXACT LOCATION IN FIELD. IF CONTRACTOR IS NOT ABLE TO 120 VOLT ELECTRICAL POWER PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD. N/A N/A LOCATE EXISTING MAINLINE CONTRACTOR SHALL PROVIDE AND INSTALL NEW MAINLINE AND MAKE ALL [jJ THE COORDINATION OF POWER AND CONNECTION OF CONTROLLER SHALL BE THE @ @ @ HUNTER -PGP-12-CV-R, ULTRA SERIES, 12" POP-UP SHRUB ,68 1.3 2.7 35 20 FT 0.46 A 17 NECESSARY CONNECTIONS FOR PROPER OPERATION OF NEW AND EXISTING IRRIGATION SYSTEM, RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ROTOR HEAD WI NOZZLES Q-.75SR/H-1.5SR/F-3.0SR (EXISTING) IRRIGATION SYSTEM TO BE ADJUSTED AND OR MODIFIED. CUT AND CAP EXISTING SYSTEM AS REQUIRED CV @ ® HUNTER -PGP-12-CV-R, ULTRA SERIES, 12" POP-UP SHRUB 1.4 2.1 3.5 35 25 FT 0.46 A 17 ROTOR HEAD WI NOZZLES Q-1,51 H-2.51 F-5.0 :U :11 ,1!,;U; FOR PROPER OPERATION. REPAIR OR REPLACE ANY DAMAGED EQUIPMENT. PROVIDE 100% COVERAGE WITH NO IRRIGATION PIPE & WIRE LEGEND PONDING, RUNOFF OR OVER SPRAY. @) (jJ) ® HUNTER -PGP-12-CV-R, ULTRA SERIES, 12" POP-UP SHRUB 1.7 2.7 5.6 35 30 FT 0.46 A 17 ROTOR HEAD W/ NOZZLES Q-2,0 I H-3.0 I F-6.0 ~ (EXISTING) REMOTE CONTROL VALVE. VERIFY AND TEST FOR PROPER OPERATION, SYMBOL MANUFACTURE I MODEL NO. I DESCRIPTION DETAIL SHEET HUNTER -PGP-12-CV-R, ULTRA SERIES, 12" POP-UP SHRUB REPAIR OR REPLACE IF DAMAGED. @ ® @ 2.1 3,5 7.0 35 35 FT 0.46 A 17 NON-PRESSURE LATERAL LINE (314" -2") SCH. 40 PURPLE "RECYCLED WATER" PVC PIPE WITH WORDS N 18 ROTOR HEAD WI NOZZLES Q-2.51 H-4.0 I F-8.0 ~ (EXISTING) REMOTE CONTROL VALVE TO BE RELOCATED AS NEEDED. VERIFY IN FIELD WITH OWNER VALVES TO "RECYCLED WATER-DO NOT DRINK" INSTALLED 12" BELOW GRADE G) @ @ HUNTER -PGP-00-CV-R, ULTRA SERIES, SHRUB ROTOR HEAD 0.46 B 17 BE REMOVED OR RELOCATED PRIOR TO CONSTRUCTION. REPAIR OR REPLACE IF DAMAGED. ON RISER WI NOZZLES 0-,50SR/H-1.0SR/F-2.0SR .43 .90 1.7 35 16 FT PRESSURE MAINLINE (1-112" SCH, 40) (2" -2-112" CLASS 315) PURPLE "RECYCLED WATER" PVC PIPE N,Q 18 -- - (EXISTING) PVC PIPE AS LATERAL LINES SHOWN FOR REFERENCE ONLY, VERIFY EXACT LOCATION IN FIELD. ------WITH WORDS "RECYCLED WATER-DO NOT DRINK" INSTALLED 18" BELOW GRADE. INSTALL WITH 3" @ @ @ HUNTER -PGP-00-CV-R, ULTRA SERIES, SHRUB ROTOR HEAD .68 1.3 2.7 35 20 FT 0.46 B 17 PROTECT IN PLACE, REPAIR ANY DAMAGE DUE TO CONSTRUCTION. WIDE "RECYCLED WATER" METALLIC DETECTABLE WARNING TAPES. ON RISER WI NOZZLES Q-.75SR/H-1,5SR/F-3.0SR ----{}-CONNECTION OF NEW LATERAL LINE TO EXISTING LATERAL LINE. T. CHRISTY -TA-DT-3-PRW, 3" WIDE DETECTABLE PURPLE "RECYCLED WATER" METALLIC BACKED N, 0, P 18 (l) ® ® HUNTER -PGP-00-CV-R, ULTRA SERIES, SHRUB ROTOR HEAD 1.4 2.1 3.5 35 25 FT 0.46 B 17 VERIFY SIZE, LOCATION AND CONNECTION POINTS IN FIELD. UNDERGROUND WARNING TAPE. INSTALL WARNING TAPE CONTINUOUSLY ALONG MAINLINE ON RISER WI NOZZLES Q-1.51 H-2.51 F-5.0 NO SYMBOL ROUTING, ONE (1) LOCATED IMMEDIATELY ON TOP OF MAINLINE ATTACHED EVERY 5' AND ONE (1) @ @ ® HUNTER -PGP-00-CV-R, ULTRA SERIES, SHRUB ROTOR HEAD 1.7 2.7 5.6 35 30 FT 0.46 B 17 LOCATED 12" ABOVE MAINLINE. ON RISER WI NOZZLES Q-2.0 I H-3.0 I F-6.0 POTABLE WATER WATER LEGEND HUNTER -PGP-00-CV-R, ULTRA SERIES, SHRUB ROTOR HEAD +,/-,,' ,.. ,-',-,,'.,.. ;3-PIPE SLEEVE -PURPLE "RECYCLED WATER" SCH 40 PVC PIPE WITH WORDS "RECYCLED WATER-DO N, 0, P 18 @ ® @ 2, 1 3,5 7.0 35 35 FT 0.46 B 17 SYMBOL MANUFACTURE I MODEL NO. I DESCRIPTION DETAIL SHEET NOT DRINK". EXTEND 12" BEYOND EDGE OF HARDSCAPE. SLEEVE SHALL BE MINIMUM TWICE THE ON RISER WI NOZZLES Q-2.51 H-4.0 / F-8.0 DIAMETER OF THE PIPE OR WIRE BUNDLE CARRIED, MINIMUM 2" SIZE. NOTE: THE HUNTER ULTRA SERIES ROTOR SHALL REQUIRE THE INSTALLATION OF THE HUNTER HSJ-0 (314") MODEL COMMERCIAL I]] AS APPROVED -BYPASS TEE FOR BUILDING RECYCLED WATER CROSS CONNECTION TEST STATION. F 17 WIRE SLEEVE -"PURPLE" SCH 40 PVC PIPE EXTEND 12" BEYOND EDGE OF HARDSCAPE. SLEEVE SHALL N,0,P 18 SWING JOINT ASSEMBLY WITH EACH HEAD. E///7//J AS APPROVED -TEMPORARY POTABLE WATER METER OBTAINED FROM THE DISTRICT AND GG 15 BE MINIMUM TWICE THE DIAMETER OF WIRE BUNDLE CARRIED, MINIMUM 2" SIZE. NOTE: NOZZLES NUMBERS WITHIN THE ROTOR HEAD SYMBOLS DO NOT EXACTLY CORRESPOND TO THE HUNTER NOZZLE NUMBERS. ® LOCATED AT A DISTRICT APPROVED POTABLE WATER SOURCE WITH A DISTRICT APPROVED NO SYMBOL IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) N,O 18 NOZZLE NUMBERS FOR QUARTER, HALF, AND FULL HEADS ARE SHOW WITHIN THE HEAD MODEL NUMBER AS SHOWN IN THE LEGEND. TEMPORARY RIP BACKFLOW DEVICE INSTALLED IMMEDIATELY DOWNSTREAM OF THE NOTE: ALL SPRAY HEAD BODIES SHALL HAVE FACTORY INSTALLED RECLAIMED WATER IDENTIFICATION CAP. TEMPORARY POTABLE WATER METER. NO SYMBOL SPEARS -DS-400, PRE FILLED ORI-SPLICE SEAL WIRE CONNECTORS WITH CRIMP SLEEVE R 19 FOR USE ON ALL WIRE CONNECTIONS, AS APPROVED -TEMPORARY POTABLE WATER 2-1/2" PVC PIPE HIGH LINE WATER FEED TO GG 15 K.B.I. • KSC-XXX-S SWING CHECK VALVE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV WHEN RCV IS NIA NIA -H"-SUPPLY THE PROPOSED RECYCLED WATER IRRIGATION SYSTEM DURING CONSTRUCTION z ANO TESTING PERIOD. LOWER THAN THE SPRINKLERS. Iii;:} AS APPROVED· FIRE SERVICE DOUBLE DETECTOR CHECK, PER CIVIL ENGINEER'S SHEETS. z KB I. -KC-XXX-S SPRING CHECK VALVE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV IMMEDIATELY NIA NIA ABOVE FIRST LATERAL LINE TEE, WHEN RCV IS HIGHER THAN THE SPRINKLERS. F AS APPROVED· FIRE LINE, PER CIVIL ENGINEER'S SHEETS AS APPROVED -SPARE CONTROL WIRES. INSTALL MINIMUM, ONE (1) COMMON AND FIVE (5) ADDITIONAL s 19 w AS APPROVED -POTABLE WATERLINE, PER CIVIL ENGINEER'S SHEETS, ® SPARE CONTROL WIRES WITH 36" MINIMUM LENGTH EXPANSION WIRE LOOP FOR ALL WIRES. INSTALL WIRES WITHIN 10" ROUND PLASTIC VALVE BOX AND LABEL LID "SW". SPARE WIRES SHALL BE A @a AS APPROVED -BUILDING POTABLE WATER METER AND R/P BACKFLOW DEVICE PER CIVIL ENGINEER'S SHEETS. DIFFERENT COLOR THAN REMOTE CONTROL VALVE WIRES. LABEL WIRES "SPARE" AT BOTH ENDS. -AS APPROVED -FIRE HYDRANT PER CIVIL ENGINEER'S SHEETS DRIP IRRIGATION LEGEND SYMBOL MANUFACTURE I MODEL NO. I DESCRIPTION GPH PSI RADIUS PREC. DETAIL SHEET RATE E:C-:-=:c..:~c..:J RAIN BIRD -XFS-P-06-12, XFS SUB-SURFACE "PURPLE" DRIPLINE. 0.60 25 NIA 0.98 T, U, 19 INSTALL DRIP TUBING ROWS 14"-16" SPACING. V,W RAIN BIRD -DRIP TUBING CONNECTIONS SHALL BE MADE USING X - -t -19 . - -. - -"RAIN BIRD XF SERIES" 17mm DRIPLINE INSERT FITTINGS . -. -. . . - - i[i)] NETAFIM -TL050MFV-1, TECHLINE AUTOMATIC FLUSH VALVE. y 20 ~ RAIN BIRD -ARV-050, AIR/VACUUM RELIEF VALVE. z 20 llll RAIN BIRD -OPERIND, DRIP SYSTEM OPERATIONAL INDICATOR AA 20 RAIN BIRD -SXB-360-1032 SERIES, FULL-CIRCLE, XERI-BUBBLER WITH 13.0 30 NIA 0.98 BB, CC 20 ~ 10-32 THREAD. EACH SYMBOL REPRESENTS (2) XERI-BUBBLERS PER (26.0) TREE LOCATED WITHIN IN-LINE DRIP TUBING AREAS. INSTALLED FOR TREES WITHOUT EXISTING TREE BUBBLER. RAIN BIRD -SXB-360-1032 SERIES, FULL-CIRCLE, XERI-BUBBLER WITH 13.0 30 NIA 0.45 DD 20 * 10-32 THREAD. EACH SYMBOL REPRESENTS (1) XERI-BUBBLER PER VINE -------' APPROVED FOR PLANTING AND COMPLETE SHEET REVISED~ LOCATED WITHIN IN-LINE DRIP TUBING AREAS. IRRIGATION ONLY, INCLUDING PRECISE ~ A A A 1 LOCATION OF PLANTING AREAS. "AS-BUILT" REVISIONS MUST BE APPROVED BY PUBLIC HEALTH ENGINEER, I SH:;-r II CITY OF CARLSBAD 11 8 "~4:•s 1 ~ ASST. PLANNING DIRECTOR AND DISTRICT ENGINEER PRIOR TO PLANNING DIVISION WARE MALCOMB IMPLEMENTATION IN FIELD. ~ 4121/16 RLA /,\ CONSTRUCTION CHANGE ~-s., .... ME: IRRIGATION LEGEND ~~s J. li1 ~ CARSLBAD OAKS NORTH -LOT 13 Leading Design for Commercial Real Estate DATE I§, 1j'J!jfot," ~ WHIPTAILLOOP 'l#'i ,{!!o • 'j ".A, EXP. CARLSBAD, CALIFORNIA 82008 (srrature) ~ architecture 6363 grccnwich dr. stc. 175 0 /06/16 -I APPROVED ~44f~\-4\-: I planning san diego. california 92122 (Doto) r#' REVIEWED BY: interiors p 858,638,7277 u>_,. 05/31/17 1841 RESEARCH DR ~'>-~--'J:"::-,..i_Exp. graphics f 858,638.7506 l"9F' CAll~ sum 200 PLANNING DATE site development IRVINE• [A 12618 DATE BY DESCRIPTION APP'D DWN BY PROJECT NO. DRAWING NO. RS 949,,a1.13n CHKD BY SOP 15-10 489-4L INSPECTOR DATE REVISIONS FIELD BY RIO,ELA.COM