Loading...
HomeMy WebLinkAboutDWG 490-1L; HMP 16-01; LO RESIDENCE; 01-07LO RES DENCE: SHEET INDEX LANDSCAPE IMPROVEMENT PLANS TITLE SHEET IRRIISATION PLAN, LEGEND 4 NOTES IRRIGATION DETAILS L-1 L-2 L-3 L-4 L-5 L-6 GENERAL NOTE THE LANDSCAPING FOR THIS SINGLE FAMILY RESIDENCE 1/'ilLL ADDRESS ALL FRONT, SIDE AND BACK YARD AREAS. THE PLANS ARE FOCUSING ON THE PLANTING AND IRRIGATION FOR ALL SLOPED AND PLANTER AREAS ON THE SITE. ALL LANDSCAPING SHALL BE THE RESPONSIBILITY OF THE HOMEOl/'iNER. CONSTRUCTION NOTES I. THE CONTRACTOR AGREES TO HOLD THE OHNER AND LANDSCAPE ARC.HITEC.T HARMLESS FROM ANY CLAIMS ARISING OUT OF HIS OPERATIONS OR THE OPERATIONS OF ANY OF HIS SUEJc.ONTRAC.TORS, MATERIAL SUPPLIES, OR AGENTS. 2. ALL LOC.AL, MUNICIPAL AND STATE LAHS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS HORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPEC.IFIC.ATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE C.ONTRAC.TOR. 3. THE C.ONTRAC.TOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES, AND SERVICES BEFORE C.OMMENC.ING HORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOHN IN THESE PLANS AND THE C.IVIL ENGINEERS IMPROVEMENT PLANS ARE APPROXIMATE ONLY. ANY DISC.REPANC.IES BETHEEN THESE PLANS AND AC.T1JAL FIELD CONDITIONS SHALL BE REPORTED TO THE OHNER OR LANDSCAPE ARC.HITEC.T IMMEDIATELY AND PRIOR TO C.OMMENC.EMENT OF HORK IN SAID AREA. 4. THE C.ONTRAC.TOR SHALL PROTECT ALL EXISTING UTILITIES AND FEATURES TO REMAIN ON, AND ADJACENT TO , THE PROJECT SITE DURING CONSTRUCTION. C.ONTRAC.TOR SHALL REPAIR, AT HIS OHN EXPENSE, ALL DAMAGE RESULTING FROM HIS OPERATIONS OR NEGLl6ENC.E. 5. THE C.ONTRAC.TOR SHALL OBTAIN THE PERTINENT EN61NEERIN6 AND/OR ARC.HITEC.TURAL PLANS BEFORE BE61NNIN6 HORK. 6. PERMITS FOR ANY C.ONSTRUC.TION DEPICTED IN THESE PLANS SHALL BE OBTAINED BY THE C.ONTRAC.TOR. 1. C.ONTRAC.TOR SHALL HAVE A VALID CONTRACTORS LICENSE REQUIRED FOR THE PARTICULAR HORK BEIN6 DONE. C.ONTRAC.TOR SHALL NOT ALLOH THE LIC.ENSE(S) TO LAPSE DURING THE C.ONTRAC.T PERIOD. 8. ALL IRRIGATION BAC.KFLOH PREVENTERS SHALL BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE GIVEN TO THE C.ITY AND THE CARLSBAD MUNICIPAL HATER DISTRICT. PIPE BETHEEN THE METER AND THE BAC.KFLOH PREVENTER SHALL BE SCHEDULE K HARD COPPER. APPROVED C.ONTRAC.T BAC.KFLOH TESTERS C.AN BE FOUND ON THE C.ITY HEBSITE AT, HHH.C.ARLSBADC.AhOV/SERVIC.ES/DEPARTMENTS/HATER/DOC.UMENTS/ REC.YC.LEDHATERBAC.KFLOHTESTERLIST.PDF (FOR REC.YC.LED HATER) HHH.C.ARLSBADCA.GOV/SERVICES/DEPARTMENTS/HATER/DOC.UMENTS/ HATERBAC.KFLOHTESTERLIST.PDF (FOR POTABLE HATER) OR GALL 438-2122 Cf. SHOULD THE SHEET 6RADED PADS NOT BE SCHEDULED FOR IMPROVEMENTS HITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING, STANDARD #I (GOVER C.ROP) HITH TEMPORARY IRRIGATION SHALL BE APPLIED. INSPECTION PROCEDURES: -INSPECTION OF THE PROJECT SHALL BE PREFORJvfED BY THE LANDSCAPE ARCHITECT OF THE 1/'iORK, OR HIS DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS. -FOLLOl/'ilNG COMPLETION OF 1/'iORK, THE LANDSCAPE ARCHITECT OF THE 1/'iORK 1/'ilLL CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMITTING THE "FINAL LANDSCAPE CERTIFICATION FORM". A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY THE CITY MUST ALSO BE MADE BY GALL THE INSPECTION REQUEST LINE. "FINAL LANDSCAPE CERTIFICATION FORM" E-MAIL TO: mikeelliott2@c.ox.net LANDSCAPE INSPECTION REQUEST PHONE LINE, 160.602.4602 CITY OF OCEANSIDE HIGHWAY ?a I '?-<:) '<:-0 IRRIISATION SPECIFICATIONS PLANTINIS PLAN 4 LEISEND PLANTING DETAILS 4 NOTES PLANTINIS SPECIFICATIONS LANDSCAPE ARCHITECT ADL PLANNING ASSOCIATES ANTHONY D. LAV'ISON 29'19' STATE ST. SUITE C CARLSBAD, CA 9'2008 (160) 129'-8631 L-1 · CITY SAN OF MARCOS CIVIL ENGINEER PACIFIC OCEAN cosr · CITY OF ENCINITAS _J VICINITY MAP DECLARATION OF RESPONSIBLE CHARGE: I HEREBY DEC-LARE THAT I AM THE LICENSED DESIGNER OF ~ORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 6105 OF THE BUSINESS AND PROFESSIONS GODE AND THAT THE DESIGN IS CONSISTENT ~ITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRA~INGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH IS CONFINED TO A REVIE~ ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF V'lORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE ~ITH THE APPROVED LANDSCAPE CONCEPT PLAN, ~ATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. BY: ANTHONY LAWSON PHONE NO: ( 160) _1=2~'i-~8~6B=--1'-----+---- REG/STRA TION NO: ~2B~4=8 __ _ S-Sl-11 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS I)· LAWs ' o,, o+ ' c...c.c_ -1 no o~•;; *~-r- ~UFO ~ AOL PLANNING ----~~L tll"illLrL ASSOCIATES -----1!:l!l!lrlilccL LAND PLANNING LANDSCAPE ARCHITECTURE 2979 STATE STREET SUITE "C" C A R L S 8 A D, C A. 9 2 0 0 B (7 60) 72 9-116 3 7 FAX: (760) 7 29-~ 32 4 DATE: 'i-12-16 JOB NO.: 21511 - SCALE: DRAWN BY: SITE 3325 VENADO ST. RANCHO COASTAL ENGINEERING AND SURVEYING 310 VIA VERA CRUZ, SUITE 205 SAN MARCOS, CA 9'2018 (160) 510-3152 ARCHITECT CAROLINE DOOLEY, ARCHITECT 29'19' STATE ST. SUITE C CARLSBAD, CA 9'2008 (160) 815-8148 V'IATER EFFICIENT LANDSCAPE DECLARATION: I AM FAMILIAR V'llTH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL $ ~ATER EFFICIENT LANDSCAPE REISULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE V'llTH THOSE REGULATIONS AND THE LANDSCAPE MANUAL. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF ~ATER. BY: ANTHONY LAWSON PHONE NO: ( 160) _1_2_'i_-8_6_B1 __ +---- REG/STRA TION NO: 2541:> EX IRA TION DA TE: B-51-11 Call: TOLL FREE 1-800 422-4133 TV-.0 V-.ORKIN6 DAYS BEFORE YOU Dl6 "AS-BUILT " EXP. ___ _ REVIEWED BY: INSPECTOR DATE DATE ------------+--+----+--+-------l [sHITfl I CITY OF CARLSBAD LH1EEfs I ---------+--+---+-----+-----l I __I_J _ PLANNING DIVISION f-----f-------+---------------------------., ---- TITLE SHEET LO RESIDENCE CARLSBAD, CA 92008 DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL ,---~----t-- O TH ER APPROVAL CfTY APPROVAL -~ t.P.PROVED t¼zA_I Cr bl\. at /'9·1-1<,;a -j PLANNING DATE -----t-----------------+--+----+----+---I ==============;;:====_:::_-=: DWN BY: __ PROJECT NO. DRAWING NO. CHKD BY:__ HMP 16-01 490-IL RVWD BY: -_-·-:·--: -... --- "1.4 I0.85@ I I .. ~.BS SEHER EASEMENT IRRIGATION HEAD LEGEND: SYM DESCRIPTION MANUFAG TURER/MODEL ARG PSI G) MP ROTATOR HUNTER / le>" RISER-HCV-MPIOOO~O VARIES 40 ® MP ROTATOR HUNTER / le>" Rl5ER-HCV-MPI0002I0 VARIES 40 @ MP ROTATOR HUNTER / le>" RISER-HCV-MPI000:360 FULL 40 @ MP ROTATOR HUNTER / le>" Rl5ER-HCV-MP2000~0 VARIES 40 . @ MP ROTATOR HUNTER / le>" Rl5ER-HCV-MP20002I0 VARIES 40 ® MP ROTATOR HUNTER/ IB" RISER-HCV-MP2000:360 FULL 40 (J) MP ROTATOR HUNTER / IB" RISER-HCV-MP:3000~0 VARIES 40 -, @ MP ROTATOR HUNTER / IB" RISER-HCV-MP:30002I0 VARIES 40 -------· ·--- ® MP ROTATOR HUNTER / 12" RISER-HCV-MP:3000560 40 CORNER VARIES ® MP ROTATOR HUNTER / 12" Rl5ER-HCV-MPLC55I5 STRIP 40 STRIP -------- o;.~ MP ROTATOR STRIP HUNTER / IB" Rl5ER-HCV-MPLC55I5 STRIP 40 --------- lli:§1 MP ROTATOR HUNTER / IB" Rl5ER-HCV-MPRC55I5 STRIP 40 STRIP % ~ SUBSURFACE DRIP NETAFIM / TEGHLINE GV TRICKLE 50 ADJUSTABLE FULL HUNTER / IB" RISER-HCVR-PCN-25 VARIES 40 * CIRCLE BUBBLER 5.0 DRIP A-15 , I" RAD. DISGHARG>E PRECIPITATION (6PM) RATE 8'-15' .1"1-.45 .40 8 1-191 .45-.51 .40 ---- 8 1-191 .15 .40 15'-21' .4-.86 .40 15'-21' .86-1.10 .40 ----- 15'-21' 1.41 .40 21'-50' .B6-2.I2 .40 21'-50' 2.12-2.15 .40 8 1-15 1 .2-.45 .40 5'Xl5' .22 .40 5'Xl5' .22 .40 5'Xl5' .22 .40 -. 1-4' 1.0/100' - -- I2"Xl811 1 .25 PER PLAN i 3/4" SPACING> 8 1-13 1 e'-19' 8 1-131 15'-21' 13'-21' 15'-21' 21 1-301 21'-30' B'-I5' 15' 15' 15' 1211-1811 12"-re11 DETAIL DETAIL H/I/J SHEET# :3 DETAIL H/I/J SHEET# :3 DETAIL H/I/J SHEET# :3 DETAIL H/I/J SHEET# 5 DETAIL H/I/J SHEET I 3 DETAIL H/I/J SHEET# :3 DETAIL H/I/J SHEET# 5 DETAIL H/I/J SHEET# 5 DETAIL H/I/J SHEET# :3 DETAIL H/I/J SHEET# 5 ------- DETAIL H/I/J SHEET# :3 DETAIL H/I/J SHEET# 5 DETAIL D/L SHEET# 5 DETAIL H/1/J SHEET# 5 I __ , ~~ ::::nt'./4J~ I I /21' NIA I NLI NE -~ ' DRIP 4.0 IRRIGATION NOTES I. IRRIG>ATION PLAN 15 DIAG>RAMMATIG. ALL IRRIG>ATION EQUIPMENT SHALL BE LOCATED IN PLANTING> AREAS ONLY, UNLESS NOTED OTHE~ISE. REFER TO THE IRRIG>ATION LEG>END AND DETAILS FOR EQUIPMENT AND INSTALLATION. 2. CONTRACTOR SHALL KEEP THE PREMISES GLEAN AND FREE OF EXCESS EQUIPMENT, MATERIALS, AND RUBBISH INCIDENTAL TO HORK OF THIS SECTION. 3. A ALL RISERS SHALL BE P.V.C. SCHEDULE BO. B. ALL PIPE FITTING>S SHALL BE P.V.G. SCHEDULE 40. 4. A ALL HIRE SHALL BE ANG>-UF, DIRECT BURIAL TYPE, AND ALL SPLICES AND CONNECTIONS SHALL BE MADE HITH PEN-TITE GONNEGTORS OR EQUAL. EAGH VALVE ON A CONTROLLER SHALL HAVE A SEPARATE HIRE GOLOR. ALL HIRES SHALL BE INSTALLED HITH THO (2) FEET OF EXCESS HIRE /COILED) AT THE END OF EAGH HIRE RUN. 8. ALL AUTOMATIC VALVES SHALL BE LOCATED HITHIN SHRUB AREAS AND INSTALLED IN G>REEN VALVE BOXES, ONE VALVE PER BOX, HITH FOUR (4) INCHES OF PEA G>RAVEL BENEATH THE VALVE. G>ATE VALVES SHALL BE LOCATED IN 5EPARATE VALVE BOXES. ALL VALVE BOX LIDS TO BE FLUSH HITH G>RADE 'i. ALL MAINLINE AND LATERAL LINES SHALL BE SLEEVED HITH P.V.G. SCHEDULE 40 Ti'<ICE THE DIAMETER OF THE SLEEVED LINE HHERE IT PASSES UNDER PAVED AREAS. 10. CONTROLLER5 SHALL BE SIZE AND TYPE AS NOTED, AND INSTALLED HHERE INDICATED ON IRRIG>ATION PLAN. CONTROL HIRES SHALL BE SLEEVED IN ELECTRICAL CONDUIT TO MAINLINE. 120 VOLT SERVICE TO CONTROLLER SHALL BE BY THE OHNER. II. PRIOR TO BACKFILLING> IRRIG>ATION TRENCHES, 3/4' ~ B. CONTROL HIRE SHALL BE BUNDLED AND PLACED BENEATH MAINLINE. A ALL MAINLINES IN THE 5Y5TEM SHALL BE GAPPED AND PRESSURE TESTED AT 125 P.5.1. FOR A PERIOD OF FOUR HOURS. ANY LEAKS FOUND SHALL BE GORREGTED BY REMOVING> THE LEAKING> PIPE OR FITTING>S AND INSTALLING> NEH MATERIAL IN ITS PLACE. .0 Fo\NT Of CONNECTION (F.O.C),LOCATED 81' NORTH OF SOUTHERN PROPERTY LINE FER CIVIL FLAN DRIP ' 3/4" CONFIRM CONTROLLER LOCATION OUTSIDE G>ARAG>E HALL AND COORDINATE POHER SOURCE 1/11/ G>EN. GONTRAGTOR. Ii' PRIVATE Jl'lATER METER (10 AVAILABLE F.S.I.) I" MASTER VALVE I" FLOJl'l SENSOR o' 1 o· 20' 40' G. PROVIDE PVC SLEEVING> FOR HIRES UNDER ALL PAVED AREAS HIDER THAN FOUR FEET AND THROUG>H ALL MASONRY HALLS. PVG SGH. 40, THICE DIAMETER OF MAINLINE /MIN. 24" COVER) 5. CHEGK VALVES SHALL BE USED HHERE INDICATED AND HHERE NECESSARY TO PREVENT HATER FLOH FROM LOHER ELEVATION HEADS HHEN SYSTEM IS TURNED OFF. 6. ALL PRESSURE MAINLINES SHALL BE EIG>HTEEN /IB) INCHES DEEP, AND ALL LATERALS THELVE /12) INCHES DEEP. TRENCH BACKFILL SHALL BE FREE OF ANY MATERIAL THAT MAY DAMAG>E IRRIG>ATION PIPE OR EQUIPMENT. IN THE EVENT OF BACKFILL SETTLEMENT, CONTRACTOR SHALL PERFORM REQUIRED REPAIRS AT HIS OHN COST. 1. ALL IRRIG>ATION HEADS HITHIN 10' OF PEDESTRIAN USE SHALL BE BELOH G>RADE OR ON POP-UPS. V'IATER BUDGET CALCULATIONS, PLANTING AREA V'IATER BUDGET = (ET0)(0.62) [(.55)(LA) + (.45)(SLA)] = (40)(0.62) [(.55)(1"1,815) + (.45)(0)] = (24.8) ( I0,"150.5 + o ) = 21IP68 GALLONS FER YEAR PRESSURE CALCULATIONS, A Rtmota ~I Valwi .... !:!!..JA■w:. Dtimand (l3PM): POCiWaler MD _A -Prt111.11'1 Av• naa: B. ALL LATERALS SHALL BE PRESSURE TESTED AT DESIG>N PRESSURE FOR ONE HOUR. 12. IRRIG>ATION CONTRACTOR SHALL MAINTAIN THE SYSTEM FOR A PERIOD OF SIXTY (60) DAYS AND SHALL HATER ON A DAILY BASIS. 15. SHOULD THE SHEET G>RADED PADS NOT BE SCHEDULED FOR IMPROVEMENTS HITHIN 6 MONTHS OF COMPLETION OF ROUG>H G>RADING>, STANDARD #I /COVER GROP/HYDROSEED) AND TEMPORARY IRRIG>ATION SHALL BE INSTALLED. 14. RAIN SENSORS SHALL BE REQUIRED FOR BOTH TEMPORARY AND PERMANENT IRRIG>ATION 13.0 70 ESTIMATED TOTAL I/IIATER USE CALCULATIONS, PLANTING AREA I) ETI/IIU = [(ETo)(0.62)][(FF x HA + IE) + SLA] = [(40)(0.62)] [(.5 X 11,151 + .1 ) + 0] = (24.8) ( 5P56 + o J = 124,8"16 GALLONS FER YEAR 2) ETI/IIU = [(ETo)(0.62)][(FF x HA + IE) + SLA] = [(40)(0.62)] [(.8 X 2451 + .1) + 0] = (24.8) ( 2,118.28 + 0 ) = 68,"102 GALLONS FER YEAR IRRIGATION EQUIPMENT LEGEND: MAINLINENALVES: ___ WlterM* lil!M lJlU ••• 2.0 5) ETI/IIU = [(ETo)(0.62)][(FF x HA + IE) + SLA] =[(40)(0.62)] [(.5 X 5,251 + .8 ) + 0] =(24.8) ( l,"16I.625 + o) SYMBOL P.O.G. ' ® @ B 0 0 $ ~ 0 ~- ■■I■■ 1■■11 ■I■ II ■■I■ ■I■ ■I■ ---- ---- DESCRIPTION MANUFAC11JRER MODEL NUMBER ------- POINT OF C.ONNECTION, (CONNECT DOV'IN STREAM OF RESIDENTIAL METER) REDUCED PRESSlJRE BACKFLOY'I PREVENTER /I") FEBC,O !l25Y -------- I 1/2" Y'IATER METER (BY OTHERS) --. ------ TEE MOUNTED FLOY'! SENSOR HUNTER FLO!fll-SYNC MASTER VALVE (NORMALLY CLOSED). Y'IITH EPOXY-COATED SUPERIOR S:200-SERIES COVER. SEE PLAN FOR SIZE, INSTALLED IN VALVE BOX. /SIZE PER PLAN) IC-bOO-PL Ill STATION CONTROLLER Y'IITH SOLAR SYNC HUNTER (2) ICM-boo, b STATION_!,iODULES REMOTE CONTROL VALVE. RAINBIRD 015-DV REMOTE CONTROL DRIP VALVE Y'IITH PRESSURE RE5ULATOR RAINBIRD XCZ-0"75-PRF AND FILTER -- BALL VALVE -LINE SIZE IN VALVE BOX SPEARS :2122,0R APPROVED EGUAL S/411 BRASS HOSE BIB AMERICAN VALVE M"T!l LATERAL LINE, PVG SCH. 40 SEE NOTES FOR PIPE DEPTH. PACIFIC PLASTICS (9/411 cmd above) MAINLINE, PVC SCH. 40 SEE NOTES FOR PIPE DEPTH. PAGIFIC. PLASTICS (UP TO 4") SLEEVES, PVC. SC.H. 40 PACIFIC PLASTICS (\JF TO 4") NOTES SEE DETAIL A, SHEET L-3 SEE DETAIL C., SHEET L-9 CONFIRM SPECIFIC LOCATION Y'IALL MOUNT ON INSIDE OF 5ARA5E (SEE DETAIL K, L-3) SEE DETAIL E, SHEET L-9 SEE DETAIL L, SHEET L-9 SEE DETAIL 6, SHEET L-3 SEE DETAIL N, SHEET L-9 SEE DETAILS F<5, SHEET L-9 SEE DETAILS F45, SHEET L-9 SEE DETAIL F, SHEET L-9 1" Stckftow Oevica "" MutarVt!\/1 "" RCV O L F. or Y' Malnllne D u=. tlf -i!'-Mallll/ll! 207 L,P, cl 1112" littlnllnt '.13,0 ■ --~-= --~---~ --,-, -~- 1> • 2.0 2.0 0.0 0.0 1.1 Sut>lohl! M•lnlITT9NM'e ?81 L011: 1:2..4 LATERAL LINES; 0 L.F-, al 2" Lelral O 0 ■ 0.0: 0 L.F.of 11ii!' Lmc<IO =M • 0.0 ff LF. of 11,.. LmraJ O 13.01 = :C.5 110 LF.m' -,•-Lmra.10 -1-0.99 • 2.S Ht L.!=,ar ~4~ LatlralO 7~■ 1.7 Bu~l LM'WII! Lin• PSI LDN: • 4.7 Lau Thw Filitil'lgl (10%) 0.5 Lan er O■in ihN __ e Tit.al Elev. Ch111Qe SublOIII Syttem PSI 1011: 2.5 20.2 TOTAL flill:SSURE AVI\ILA.BLE: SUBTOTAL SVSTEM LOSS: 1-'RISSSURJ: Rl:QUIReO Ar Hl:Ab: TQT,tJ. PflJ:SSURE LOSSES: RESIDUAL WATER PRESSURE 20.2 ~IO.O 71J.O Call: TOLL FREE 1-800 422-4133 THO HORKING> DAYS BEFORE YOU Dl5 = 48,648 GALLONS FER YEAR 4) ETI/IIU = [(ETo)(Oh2)][(FF x HA + IE) + SLA] = [(40)(0.62)] [(.5 X 460 + .15) + 0] = (24.8) ( 506h + 0 ) = 1,605 6ALLONS FER YEAR TOTAL ETJl'lU = 250,051 FER YEAR "AS-BUILT ,, EXP. DATE REVIEWED BY, INSPECTOR DATE AOL PLANNING --- ASSOCIATES t----+--------+-------------+---+----+----+-----< I SH2EET I CITY OF CARLSBAD I SHlEETS I ~===--'=====P:::::LA:::::N:::::N:::::1:::::NG:::::::::D:::::IV:::::IS:::::10::::N===='-'==~ LAND PLANNING LANDSCAPE ARCHITECTURE 2979 STATE STREET SUITE "c" C A R L S B A D, C A. 9 2 O O 8 IRRIGATION PLAN, LEGEND AND NOTES LO RESIDENCE CARLSBAD, CA 92008 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS (760)729-8637 FAX:{760)729-IIJH DATE: ~-12-16 JOB NO.: 2151"1 SCALE: DRAWN BY: DATE INITIAL ENGINEER OF WORK DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL DWN BY: DATE INITIAL CHKD BY: __ _ CllY APPROVAL RVWD BY: PROJECT NO. HMP 16-01 __ E -1-1.s.,_ DATE DRAWING NO. 490-IL • 0 1 y INSTALL SLEEVE5 FOR MAIN LINE -----________ L ____ PIPE AND CONTROL ,'!IRES THAT CROSS UNDER PR.JVE-~Y5 U51NiS SCH. 40 SLEEVES ;-!ITH A COYER OF 24" Ml'N. """'' AU. "60YI: eioAADE PIF'E 5HALL. SE. INSTAU.ED "'5 ~- IIIRl<IAT10N W.INL.ll£ -t ... ,_,, ITO VM.VP!!J) P.O.C. I . POINT OF CONNECTION TO tl0Me5TIC I I/ I • "' MTER SERVICE TO BE IMMEDIATELY I """'' -· OOY<NSmEAt-1 OF THE Ml;Tl;R I . INSTALL "T" FITT/1',1$ j,',j/n,f BAU. I VALVE, (LINE SIZE) TO ALI.Oi'<I I , SH.JT-of'F OF IRRlcS,ATION AND ROlJTe i I MAIN!..INE TO BAGKl"l.Ot1 DEVICE. • LOG,ATE BAGl<FLOYi A5 CLOSE TO POC AS POSSlet..E:. BACKf'LOYi MUST ~----r~ 61: OUT OF t=IJBLIC R.OY-l, }IND t& SGREENE:D FROM POTENTIAL DAMA6E, , """"-""-1 I ~VM.VE --~---· ~ "'"'""" 1 i BLOCKED TRUE UNION BALL VALVE @ V,A.LVE eox -SEE IRRIGATION SPEC-5. FINISH 5'RADE 6 SLIP END CONNECTORS SUPPLIED @ ,'IITH VALVE PVC MAINLINE-5EE IRRl<!,ATION 5PEC5. FOR PIPE DCPTH PEA <!,RAVEL, :2" DEPTH 4" ;-!IDE BRICK SUFPORT, ONE PLACED AT EACH CORNER NOJE, VALVE SHALL HAVE A MINIMUM OF 4" Cl.EAl<ANCE Ff':GM 11£ BOTTOM OF THE VAi.VE BOX LID, AND 2" MINIMUM GLEAl<ANCE l'ROM 11£ BOTTOM OF VAi.VE AND ToP OF GRAVEL 5UMF. @ TYPICAL RESIDENCE P.O.C @BALL VALVE N.T.S. ' ' ~! ,., ~ CD RECTANGULAR PLASTIC VALVE BOX VV LOGKING 60L T LID @ ELECTRIC REMOTE CONTROL VALVE FINISH GRADE PVC LATERAL LINE PIPE 5 --I 1 ,- I 5/4" CRUSHED ROCK SUMP PRESSURE SUPPLY LINE 5GH. BO UNION 5GH. BO PVC MALE ADAPTER 4 ::2 CD PAVING @ LATERAL LINE (IN SLEEVE) • ----(I) 4 6)[ (@r!G I -~' ~~-----"---~~J .2" MIN :2" MIN BACKFILL 56" GOVER UNDER VEHIGLE PAVIN5 /11/ 5GH. BO SLEEVE PVC SGH. 40 "10 DEGREE ELL (SXT) @ SC,H. eo NIPPLE (TYP) @ 4" Jl'IIDE BRICK SUPPORT ONE PLAGED AT EAGH CORNER @ PRESSURE SUPPLY LINE (IN SLEEVE) IE>" GOVER UNDER PEDESTRIAN PAVING VV SGH 40 SLEEVE G) GONTROL Jl'IIRES (IN GONDUIT) *ALL SLEEVES TO BE TV'IIGE DIAMETER OF PIPE @ REMOTE CONTROL VALVE N.T.S. ®SLEEVING UNDER PAVEMENT (;, NOTE: ll'IALL SEGTION /4+-----E:XISTIN5 BLIIU,IN,S OR ''''"''"" ....,_ 1----AUTOMATIG CONTl'i.01.J...ER (MOUNTIN6 PER WOOJFAC!'l~'S SFfC.IFICATIOH5) ---P'IC,SGH. -40CH,t,5E SGH. '40 PVG <10" SreEP ELL ' ' ' ELEVATION ' oos1-:-1> I:> • (II)-- ""'"''""'-SUPPi. y/· GONOUIT. _/ GONNEGTTO~ 501/RCE. - J eox IJ<EIOE GONlROLLER. ~ ~IIE: IN afC1RIGAJ. GONt:\.IIT, S/4". I. COORDINATE PO)'IIER SOURCE V'IITH 61:NERAL CONTRACTOR. 1. PAINT CONTROLI.ER, METAL STRAPS, AND 9CH. 40 c:.HA$E ABOVE 6RADE) TO MATCH AOJAC.ENT ViALL COLOR. ® EXTERIOR V'iALL MOUNT CONTROLLER NOTE, MOUNT RAIN 5EN50R ON ANY' SURFAC!: ~ IT )'lljll. BE f;Xf'05f:D TO IJNOeSTRl,JC,TEP RAINFALL, SUT NOT IN THE PATH OF SFRINKLl:R SPRAY. RAIN SENSOR N.T.5. N.T.5. CD (2) @ @) @ C REDUCED PRESSURE BACKFLO~ @ UNION PREVENTER (J) PVC SxT COUPLING BALL VALVE F'RE55URE RE5ULATOR* @ PVC PRESSURE SUPPLY LINE, /SET TO 00 PSI) ® TRENCH DEPTH, /REFER TO NOTES) BRASS RISER OR NIPPLE BRASS ELB0,'1 (T,'IO REQIJIREDJ @ FINISH <!,RADE NOTE, PRESSURE: RE$ULATOR 15 ONLY REQUIRED IF STATIC k'iATER PRE55URE 15 AflOVE 80 F51. BACKFLOV'i PREVENTER z z f X N d.i A / _L__ b" MIN. CD FINISH 5RADE @) LATERAL LINE ' II f I" 1 '- 0 ~-+---I ------i@ @ GONTROL Jl'IIRES @ BAGKFILL @ PRESSURE SUPPLY LINE *INSTALL GONTR.OL V'IIRES ON THE UNDERSIDE OF PRESSURE SUPPLY LINE. TRENCHING IN LANDSCAPE 0 FINl5H5AADE @ V"1.ve. eox ~ln-t c.oveR N.T.S. N.T.S. 23-4567 8 9 10 @ 80-~ LIIEAA LBl6TH Cf' 11~ GOil.ED ~11:FIPRooF GONl'EGTk:lN ~ /-INCH fMU. VAL.VE IDTM ~R&br!~VAJ..VE © ~ re61,LA,TIN6 GIJIQ:; GIEQ< """1Fll."" ® f"/G 9G+! '40 FeM,,l,U: ,i,D,l,PTOR LA'TERl,L PIP! @) @ PI/G SCH e0 NIPPLE (l..!!N&'IH le, ~I~) P-k,SGl-l-401::U. @ PI/G 9G+! kl IIJPPLE /2-IHGtl 1.ENS-nt, @) HfC)tll!N,ll,KlPI/G5CH~W. PI/GSGl-+40'115aOREU. ® M,l,JNLIIE Plf'f @ ~ ~va., S' Milt. DfPTH @ F'VG 5GH eo Nlf'!"LE, Gl.O!le @ BRICK et.ffllRT @S'IK'Mil",~MEM XFCV Dripline Maximum Later.ii Lengthg \Feet) lnlel Pressure psi Nominal Flow (gf'."•I Nominal Flaw (~ph) ••• ... • •• w '"' ,~ 25~ '" '" 205 '"' '" ·~ "" "' •• m ,,, ,n 0 PVG EXHAUST HEAOER ® 0 PVG SCH 40 TEE OR EL (TY'PIGAW BARB X MALE FITTING: RAIN BIRD XFF-MA FITTJN6 (TYP)CAL) 0 FUJ5H POINT/VALVE/CAP (TYPICAL) (LOCATE AT LO~ ENO OF CIRCUIT) © PERIMETER OF AREA © PERIMETER PRIPLINe PIPE TO SE INSTAl..LED :2"-4" FROM PERIMETER OF AREA 0 5UB 5URFAGE DRIPLINE: RAIN BIRD XF SERIES DRIPLINe (TY'PIGAW POTABLE: XFCV DRIPLINE 7 ,_ -!"" i i..-----0 I ' a..;..;;. ..... ',i}':!1'7:r·)i.•."";;.:: .;;..,I NOTE, 0 FINISH <!,RADE @ FL.USH GAP FOR EASY FIT COMPRE55ION FITTIN65, POTABLE,RAIN BIRD MDCFCAP @ EASY FIT COUPLIN<!,, RAIN BIRD MDCFCOUP 0 SUBTERRANEAN EMITTER BOX, RAIN BIRD 5EB iXB @ SUB-SURFAcE DRIPUNE, RAIN BIRD XF SERIES DRIFL.INE POTABLE, XF5 DRIPLINE @ 5-INCH MINIMUM DEPTH OF S/4-INCH l"IA5HED <!,RAVEL {z) BRICK (I OF 2) @ PVC SUPFLY HEADER I. ALLO~ A MINIMUM OF 6-INGHE5 OF DRIPLINE llJBING IN VALVE BOX IN ORDER TO DIRECT FLUSHED Y-J.ATER OUTSIDE VALVE BOX. ® P\IC DRIP MANIFOLD FROM VALVE KIT (SIZED TO MEET LATERAL FLOY\ DEMAND) NOTES, FLUSH VALVE/GAP @) AIR RELIEF VALVE @ I. LEN5TH OF LON6E5T DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACIN<!, 5HO,'!N IN THE ACCOMPANYIN<!, TABLE. PVC SCH 40 RISER PIPE LAYOUT 2. ffiEN U5IN5 liMM INSERT FITTIN65 r'!ITH DE5I6N PRESSURE OVER 50PSI, IT 15 RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTIN<!,. @ RAINBIRD SUB-SURFACE IRRIGATION SYSTEM @ n l I ,·---I i 2 -•I ' ' ' ' ' ' ti Jl'IALK, CURB, HEADER, ETC-. FINISH 5RADE POP-UP HEAD GHEGK VALVE (IF REQUIRED) SJl'IING JOINT ASSEMBLY, @ l/2"Xe," SGH BO PVC NIPPLE Jl'IITH THREE STREET ELLS @PVC FITTING AS NEEDED (J}PVG LATERAL SUPPLY LINE @ VARIES, ALLOJl'I le" FROM BAGK OF CURB ADJAGENT TO "HEAD-IN" PARKING AREAS (AREAS Y'IHERE FRONT OR BACK OF GAR Jl'IILL EXTEND OVER PLANTIN5 AREA) ALLOJl'I 12" FROM ANY VERTIGAL SURFACES AND 2" TYPICAL AT ALL OTHER LOCATIONS. GEAR DRIVEN ROTOR FINISH GRADE LATERAL LINE PIPE TEE IN LATERAL LINE PIPE 5/4" X 2" SCH. e,o NIPPLE MIP X FIP STREET ELL 12" 5GH. BO NIPPLE MIP X FIP STREET ELL ' , i ' NOTE: 0 FINISH <!,RADE @ SUBTERRANEAN EMITTER BOX, RAIN BIRD 5EB 1XB @ ½" AIR RELIEF VALVE, RAIN 61RD ARV050 TO BE INSTALLED AT Hl5H POINTS IN DRIP ZONE (±) PVC SCH 40 FEMALE ADAPTER ® PVC SCH eo RISER @ BRICK /I OF 2) {z) PVC HEADER PIPE @ PVC SCH 40 TEE ® 3" MJNJMUM PEPTH OF ¾" ,'!ASHED <!,RAVEL I. AIR RELIEF VALVE MUST BE LOCATED AT Hl<!,HEST ELEVATION/SJ OF CJRCUIT. ::2. PROVIDE AS NEEDED AND AS PER MANUFACTURER'S RECOMMENDATIONS. AIR RELIEF VALVE ' 1---I ' -- I (D SHRUB SPRAY ON RISER @ SCH. 80 RISER i 12" MAXIMUM FIN I SH GRAPE 12" MINIMUM N.T.S. @ 2 PVC SCH. 40 ELLS (T X T) $ 2" PVC SGH 80 THREADED NIPf'LE @ BUILDIN~ HARDSGAPE, GONGRE,E SIDE V'IALK ~ PVC-SGH. BO NIPPLE PVC SCH. 40 STREET ELL PVC LATERAL LINE @ 12" MINIMUM NOTE, PROVIDE ANTI DRAIN VALVE IN LINE. STAKE ALL RISERS OVER 12" TALL. H POP UP ROTOR/SPRAY (SHRUBjT_s(DPOP UP ROTOR/ SPRAY (TURFJT.s. Q) SHRUB SPRAY ON RISER N.T.S. POP-UP Jl'II TH SUBLER FINISH GRADE LATERAL LINE PIPE TEE IN LATERAL LINE PIPE CD @ 5/4" X 2" SCH. e,o NIPPLE MIP X FIP STREET ELL 12" SCH. BO NIPPLE MIP X FIP STREET ELL (])7 ! +-----,-,-.-,~_-, ,f-, -,.,I 1,-,,--,--'--;;:_- (D HOSE BIB ON RISER @ SGH. BO RISER @ 2 PVC SCH. 40 ELLS (TX T) $ 2" PVC SCH BO THREADED NIPPLE ~ PVC, SCH. 50 NIPPLE PVC SCH. 40 STREET ELL PVC LATERAL LINE ' ' -· I i I 12" MAXIMUM FINISH GRADE 12" MINIMUM @ THREADED COUPLER NOTE, PROVIDE ANTI DRAIN VALVE IN LINE. STAKE ALL RISERS OVER 12" TALL. DRIP LINE VALVE KIT N.T.S. (8) POP UP BUBBLER N HOSE BIB ON RISER N.T.S. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS ADL PLANNING --- ASSOCIATES __ _ LAND PLANNING LANDSCAPE ARCHITECTURE 2979 STATE STREET SUITE "C" C A R L S B A D, C A. 9 2 0 0 8 (760)72S-8637 FAX:(760)729-!JH DATEc '1-12-16 ----- JOB NO.: 21511 SCALE: DRAWN BY: DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION Call: TOLL FREE 1-800 422-4133 TJl'IO Jl'IORKING DAYS BEFORE YOU DIG REVIEWED BY: INSPECTOR "AS-BUILT " EXP. DATE DATE I s .. HEET ]-CITY OF CARLSBAD --+----t------l Ls PLANNING DIVISION --+-->-----J IRRIGATION DETAILS LO RESIDENCE CARLSBAD, CA 92008 rROVED DATE l.~NNING INITIAL~_D_M_E_ r-lN-IT-IAL~ g~~~D~B=~=~=: =~· -] OTHER APPROVAL CITY APPROVAL RVWD BY: _ __ __ PROJECT NO. J HMP 16-01 e·•-1',o I DATE DRAWING NO. 490-IL SECTION 02441 IRRIGATION SYSTEM PART I -GENERAL I.I DESCRIPTION A. l"iORK INCLUDED, PROVIDE IRRIGATION SYSTEM l"iHERE 5HOHN ON DRAHING5, AND AS SPECIFIED HEREIN, COMPLETE IN PLACE, TESTED AND APPROVED, INCLUDING BUT NOT NEGE5SARIL Y LIMITED TO, I. F.O.G., CONNECTION OF SYSTEM TO EXISTING l"iATER SUPPLY, 2. REVIEH OF UTILITY PLANS 5HOl"ilNG OTHER UNDERGROUND FACILITIES, 5. TRENCHING AND BACKFILL, 4. SHRUB SPRINKLER SYSTEM, 5. AUTOMATIC CONTROLLER AND REMOTE CONTROL VALVES, b. ANY INCIDENTAL l"iORK NOT 5HOl"iN OR SPECIFIED l"iHIGH CAN REASONABLY BE INFERRED AS FART OF l"iORK AND NECESSARY TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. El. RELATED l"iORK, I. DOCUMENTS AFFECTING l"iORK OF THIS SECTION INCLUDE, BUT ARE NOT NEGE55ARIL Y LIMITED TO GENERAL CONDITIONS AND OTHER 5EGTION5 OF THESE 5PEGIFIGATION5. 2. SECTION 024"11, PLANTING. 1.2 PERMITS, FEES, CODES AND SAFETY ORDERS A. OBTAIN ALL PERMITS AND PAY REQUIRED FEES TO ANY 50VERNMENTAL A5ENCY HAVIN5 JURISDICTION OVER l"iORK. ARRAN5E FOR IN5PEGTION5 REQUIRED BY LOCAL ORDINANCES DURING THE COURSE OF GON5TRUGTION AS REQUIRED. ON C,Otv!PLETION OF l"iORK, 5ATl5FAGTORY EVIDENCE SHALL BE FURNISHED TO LANDSCAPE ARCHITECT TO 5HOH THAT l"iORK 15 IN ACCORDANCE l"ilTH ORDINANCE AND GODE REQUIREMENTS. El. CONFORM l"ilTH APPLICABLE GODE5, STANDARDS AND OTHER APPLICABLE LAl"i5 OR RE5ULATION5. NOTHING, IN DRAl"ilNG OR 5PEGIFIGATION5 SHALL BE CONSTRUED TO PERMIT l"iORK NOT GONFORMIN5 TO GODE5. SHOULD GON5TRUGTION DOCUMENTS OR IN5TRUGTION5 VARY FROtvl AFOREMENTIONED RULES AND REGULATIONS, NOTIFY LANDSCAPE ARCHITECT, Al"iAIT INSTRUCTIONS BEFORE PROGEEDIN5 l"ilTH l"iORK AFFECTED. 1.5 QUALITY A55URANGE A. USE ADEQUATE NUtvlBER OF SKILLED HORKMEN HHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN NEGE55ARY GRAFTS AND ARE GOMPLETEL Y FAMILIAR l"ilTH 5PEGIFIG REQUIREMENTS AND METHODS NEEDED FOR PROPER PERFORMANCE OF l"iORK OF THIS SECTION. El. ALL MATERIALS THROU5HOUT 5Y5TE'1 SHALL BE NEl"i AND PERFECT CONDITION. DECISION OF LANDSCAPE ARCHITECT SHALL BE FINAL IN DETERtvllNATION OF QUALITY OF '1ATERIAL5, EQUIPMENT, l"iORK'1AN5HIP. 1.4 EXl5TIN5 SITE CONDITIONS A. CONTRACTOR SHALL ACQUAINT HIMSELF HITH ALL SITE CONDITIONS. SHOULD UTILITIES NOT 5HOl"iN ON PLANS BE FOUND DURIN5 EXCAVATIONS, CONTRACTOR SHALL PROMPTLY NOTIFY LANDSCAPE ARCHITECT FOR IN5TRUGTION5 FOR FURTHER ACTION. FAILURE TO DO SO l"ilLL tv!AKE CONTRACTOR LIABLE FOR ANY AND ALL DAMAGE THERETO ARl51N5 FORM HIS OPERATIONS, SUBSEQUENT TO DISGOVERY OF 5UGH UTILITIES NOT 5HOl"I ON PLANS. El. CONTRACTOR SHALL tv!AKE MINOR ADJUSTMENTS TO SPRINKLER SYSTEM LAYOUT AS MAY BE REQUIRED, AND MAY BE REQUIRED TO HORK AROUND EXISTING CONSTRUCTION AT NO INCREASE IN G05T TO Ol"iNER. 1.5 DELIVERY, 5TORA5E AND HANDLIN5 PROTECT l"iORK AND MATERIALS UNDER THIS SECTION FROtvl DA'1A5E DURIN5 GON5TRUGTION AND STORAGE. POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS SHALL BE ESPECIALLY PROTECTED FROM DIRECT SUNLIGHT. lh 5UB5TITUTION5 NO DEVIATIONS FROM SPECIFIED EQUIPMENT OR INSTALLATION PROCEDURES SHALL BE ALLOl"iED l"ilTHOUT HRITTEN APPROVAL OF LANDSCAPE ARCHITECT. 1.1 5UBMITTAL5 A. AS-BUILT DRAl"ilNG5, PREPARE ON BLUELINE PRINT 5HOl"ilNG DEVIATIONS FROM BID DOCUMENTS MADE DURING CONSTRUCTION AFFECTING MAIN LINE PIPE, CONTROLLER LOCATIONS, VALVES AND SPRINKLER HEADS. A5-BUILT5 SHALL BE DELIVERED TO LANDSCAPE ARCHITECT BEFORE FINAL AGGEPTANGE OF l"iORK. El. SUBMIT A LIST OF ALL IRRIGATION EQUIPMENT USED, MANUFACTURER'S BROCHURES, MAINTENANCE MANUALS, GUARANTEES AND OPERATING IN5TRUGTION5. 1.8 5UARANTEE LEAKS OR DEFECTS IN MATERIAL, EQUIPMENT, l"iORK'1AN5HIP TO 5ATl5FAGTION OF LANDSCAPE ARCHITECT. A. GUARANTEE ALL l"iORK FOR ONE YEAR FROtvl ACCEPTANCE DATE AGAINST DEFECTS IN MATERIAL, EQUIPMENT, AND HORKMAN5HIP. GUARANTEE SHALL GOVER DAMA5E REPAIR TO ANY PART OF PREMISES RE5UL TING FROM LEAKS OR DEFECTS IN MATERIAL, EQUIPMENT, l"iORKtvlANSHIP TO 5ATl5FAGTION OF LANDSCAPE ARCHITECT. El. REPAIRS SHALL BE DONE PROMPTLY UPON NOTIFICATION BY LANDSCAPE ARCHITECT AT NO COST TO Ol"iNER. PART 2 -PRODUCTS 2.1 PIPE A. FVG PLASTIC PIPE, I. PRESSURE tv!AINLINE , BELOl"i GRADE SHALL BE SCHEDULE 40 PVC. BELOl"i GRADE LARGER THEN 2" SHALL BE GLA55 515 PVG. 2. NON-PRESSURE LATERAL LINES, SHALL BE SCHEDULE 40 PVC. 5. FITTINGS, SCHEDULE 40 PVG. 4. SOLVENT GEtvlENT, AS RECOMMENDED BY MANUFACTURE OF PIPE AND OF PROPER GON515TENGY. El. BRA55 PIPE AND FITTINGS SHALL BE STANDARD 125 FOUND CLA55 85% RED BRA55. 2.2 RISERS A. SHRUB HEADS, GREY SCHEDULE 80 PVC RISERS CONNECTED TO ABOVE GRADE LATERAL LINE PER DETAILS. RISERS HEIGHT 15 MEASURED FROM FINISH GRADE TO TOP OF RISER. RISERS SHALL BE 1/2" DIAMETER UNLESS OTHERl"il5E NOTED ON PLANS. 2.5 SPRINKLER HEADS PER LEGEND AND DETAILS ON DRAHING5. 2.4 VALVES A. BALL VALVES, PROVIDE 125 PSI RATED VALVE (LINE SIZE) FER LEGEND AND DETAILS ON DRAl"ilNG5. El. QUICK COUPLER VALVES, PER LEGEND AND DETAILS ON DRAl"ilNG5. G. AUTOMATIC AND MANUAL CONTROL VALVES, PER LEGEND AND DETAILS ON DRAl"ilNG5. 2.5 BAGKFLOl"i PREVENTER PROVIDE BAGKFLOl"i PREVENTER5 SHOl"iN ON LEGEND AND INSTALL PER DETAILS ON DRAHING5. 2.b AUTOMATIC, CONTROLLER A. PROVIDE CONTROLLER 5HOl"iN ON LE5END ON DRAl"ilNG5. El. CONTROL l"ilRE5, 24 VOLT SOLID l"ilRE U.L. APPROVED FOR DIRECT BURIAL IN GROUND. BLACK #14 UF DIRECT LEAD AND HHITE #/2 UF COMMON 5ROUND, UNLE55 OTHERl"il5E NOTED ON PLANS. 2.1 OTHER MATERIALS A. PLASTIC VALVE BOXES, PROVIDE GREEN PLASTIC VALVE BOXES l"ilTH LIDS FOR BALL VALVES /ROUND) AND AUTOMATIC CONTROL VALVES /2 PER BOX MAXIMUM.) PLACE b" DEPTH OF PEA GRAVEL AT BASE OF BOXES. El. CHECK VALVES, PROVIDE SPRING IN-LINE GHEGK VALVES /LINE SIZE) PER PLAN AND AS REQUIRED TO PREVENT LOl"i HEAD DRAINAGE. G. PROVIDE OTHER MATERIALS NOT 5PEGIFIGALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND PROPER INSTALLATION AS SELECTED BY CONTRACTOR SUBJECT TO AFPROVAL OF LANDSCAPE ARCHITECT. PART 5 -EXECUTION 5.1 SURFACE CONDITIONS A. VERIFY FINISH GRADES AND SURFACE DRAINAGE Y'IITH LANDSCAPE ARCHITECT PRIOR TO Y'IORK. 13. EXAtvllNE AREAS AND CONDITIONS UNDER Y'IHIGH l"iORK HILL BE PERFORMED. CORRECT CONDITIONS DETRltvlENTAL TO TIMELY, PROPER COMPLETION OF l"IORK. DO NOT FROGEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. 5.2 FIELD MEASUREMENTS MAKE NECESSARY MEASUREMENTS IN FIELD, ENSURE FREGl5E FIT OF ITEMS IN ACCORDANCE Y'IITH DE515N. 5.5 LAYOUT A. LAYOUT Y'IORK AS AGCURA TEL Y AS POSSIBLE TO DRAl"ilNGS. DRAY'IINGS, THOUGH CAREFULLY DRAY'IN, ARE GENERALLY DIAGRAMMATIC TO EXTENT THAT OFFSETS AND ALL FITTINGS ARE NOT SHOl"IN. SITE CONDITIONS Y'IILL NOT ALY'IAYS PERMIT LOCATING PIPING, VALVES AND HEADS Y'IHERE SHOY'IN. THIS SITUATION SHALL BE BROUGHT TO IMMEADIATE ATTENTION OF LANDSCAPE ARCHITECT AND RELOCATION DETERMINED IN JOINT CONFERENCE. CONTRACTOR l"ilLL BE HELD RESPONSIBLE FOR RELOCATING ANY ITEMS l"ilTHOUT FIRST OBTAINING LANDSCAPE ARGHITEGT'5 APPROVAL AND SHALL REMOVE AND RELOCATE SUCH ITEt--15 AT HIS OY'IN EXPENSE IF 50 DIRECTED BY LANDSCAPE ARCHITECT. B. Y'IHERE PIPING 15 5HOY'IN ON DRAl"ilNGS TO BE UNDER PAVED AREAS BUT RUNNING PARALLEL AND ADJACENT TO PLANTING AREAS, THE INTENTION 15 TO INSTALL PIPING IN PLANTED AREA. G. MINOR CHANGES IN EQUIPMENT LOCATION FROM LOCATION 5HOY'IN ON DRAY'IING5 SHALL BE MADE AS DIRECTED BY LANDSGAPE ARCHITECT AT NO ADDITIONAL G05T TO OY'INER PROVIDING 5UGH CHANGE 15 ORDERED BEFORE COMENCEMENT OF l"iORK, OR Y'IORK DIRECTLY CONNECTED, AND NO ADDITIONAL MATERIALS ARE REQUIRED. 5.4 TRENCHING AND BACKFILL TRENCH, BACKFILL AND COMPACT IN ACCORDANCE l"ilTH INDUSTRY STANDARDS. 5.5 INSTALLATION OF PIFING A. ON GRADE PIPING UVR PRESSURE MAINLINE-SHALL BE SECURED Y'IITH FIFE TIE DOl"IN PINS AT A MAXIMUM OF 8' SPACING. UVR NON-PRESSURE LATERAL-SHALL BE SECURED Y'IITH PIPE TIE DOY'IN PINS AT A MAXltvlUM OF 13' 5PAGIN5. B. FIFING UNDER FAVEtvlENT, I. SLEEVE PIPING UNDER PAVED AREAS AS INDICATED ON DRAV',INGS. 2. PIFIN5 MAY BE INSTALLED UNDER EXISTING PAVEtvlENT BY JACKING, BORING, OR HYDRAULIC DRIVING EXCEPT THAT NO HYDRAULIC DRIVING Y'IILL BE PERMITTED UNDER ASPHALT CONCRETE PAVEMENT. 5. l"iHERE GUTTING OR BREAKAGE OF EXISTING PAVEMENT 15 NECESSARY, SECURE FERMl5SION FROM LAND5CAFE ARCHITECT BEFORE CUTTING OR BREAKIN6 PAVEMENT, THEN MAKE NECESSARY REPAIRS AND REPLACEMENTS TO APPROVAL OF LANDSCAPE ARCHITECT AND AT NO ADDITIONAL COST TO OV',NER. C. INSPECTION OF MATERIALS, CAREFULLY INSPECT PIPE AND FITTINGS BEFORE INSTALLATION, REMOVING ALL DIRT, 5GALE AND BURRS, REAMING AS REQUIRED. INSTALL PIPE l"ilTH '1ARKING5 UP FOR VISUAL INSPECTION. D. PLASTIC /UVR) PIPE, I. EXERCISE CARE IN HANDLING, LOADING, UNLOADING AND STORING PLASTIC PIPE AND FITTINGS, A. STORE UNDER GOVER FORM DIRECT SUNLIGHT UNTIL READY TO INSTALL, 13. TRANSPORT ONLY ON A VEHICLE Y'IITH A BED LONG ENOUGH TO ALLOY', THE FIFE TO LAY FLAT TO AVOID UNDUE BENDING AND CONCENTRATED EXTERNAL LOAD. 2. ANY DENTED AND DAtvlAGED PIPE SHALL BE DISCARDED UNLESS 5UGH DENTED OR DAMAGED SECTION 15 CUT OUT AND FIFE REJOINED l",ITH A COUPLING. 5. IN JOINING, USE ONLY SPECIFIED SOLVENT, MAKE JOINTS IN ACCORDANCE l",ITH MANUFACTURE'5 RECOMMENDATIONS. PIPE AND FITTINGS SHALL BE THOROUGHLY GLEANED OF DIRT, DUST, MOISTURE BEFORE APPLYING SOLVENT. CLEAN OFF EXCESS SOLVENT. ALLOl"i SOLVENT Y'IELD5 AT LEAST 15 MINUTES SET-UP TIME BEFORE MOVING OR HANDLING AND 24 HOURS CURING TIME BEFORE FILLING l"ilTH Y'IATER. 4. SNAKE LINES FROM SIDE TO SIDE IN TRENCH TO ALLOl"i FOR EXPANSION AND CONTRACTION. 5. PLASTIC TO METAL JOINTS SHALL BE MADE l"ilTH PLASTIC MALE ADAPTERS. USE ONLY LIGHT PRESSURE l"IITH A STRAP l"iRENCH. E. PLUG OR GAP ALL OPENINGS UPON LINE INSTALLATION TO PREVENT THE ENTRANCE OF MATERIALS THAT l"iOULD OBSTRUCT PIPE. LEAVE IN PLACE UNTIL REMOVAL 15 NEGE55ARY FOR COMPLETION OF INSTALLATION, F. THOROUGHLY FLUSH ALL LINES, PERFORM HYDROSTATIC TESTING IN ACCORDANCE l",ITH PARAGRAPH BELOV',. 5.b INSTALLATION OF EQUIPMENT A. SHRUB SPRINKLER HEADS, I. INSTALL IN PLANTING AREAS Y'IHERE INDICATED ON DRAV',ING5. 2. LOCATE SHRUB HEADS b" FROM PEDESTRIAN PAVING, 12" FROM AUTOMOBILE TRAFFIC HITHOUT CURBS, b" FROM AUTOMOBILE TRAFFIC l",ITH CURBS AND 12" FROM ALL BUILDING AND V',ALL FOOTINGS UNLE55 NOTED OTHERV'il5E. SET SHRUB HEADS EIGHTEEN (113") INCHES ABOVE FINISH GRADE UNLESS NOTED OTHERV',15E. /SEE DETAILS.) 5. USE JOINT COMPOUND ON GALVANIZED IRON FITTINGS. 4. UPON COMPLETION OF TESTING, CONTRACTOR SHALL COMPLETE AS5EMBL Y AND ADJUST SPRINKLER HEADS FOR PROPER DISTRIBUTION. El. VALVES, INSTALL BALL VALVES AND QUICK COUPLER VALVES FER DRAl"ilNGS. G. CONTROL VALVES, INSTALL l"iHERE SHOl"IN ON DRAl"ilNGS, LOCATING IN CLUSTERS IN PLANTING AREAS l"lHERE PRACTICAL. PLACE NO CLOSER THAN 12" AND PARALLEL TO V',ALK EDGES, BUILDINGS AND l"iALLS. HOUSE IN VALVE BOXES l"llTH TOPS SET NO GRADE AND ANCHORED. D. BACKFLOl"i PREVENTER, INSTALL l"iHERE INDICATED ON DRAl"llNG5 AND IN AGGORDANGE l"IITH ALL PERTINENT CODES, REGULATIONS, AND MANUFACTURER'S RECOMMENDATIONS AS APPROVED BY LANDSGAPE ARCHITECT. E. AUTOMATIC CONTROLLER, I. INSTALL CONTROLLER AS 5HOV',N ON DRAl"ilNG5, UNLESS OTHERV',15E DIRECTED BY LANDSGAFE ARCHITECT. 2. CONNECT REMOTE CONTROL VALVES TO CONTROLLER IN SEQUENCE CORRESPONDING TO SEQUENCE INDICATED ON DRAl"ilNG5. l"iHERE Tl"iO OR tv!ORE VALVES HAVE SAME NUMBER, l",IRE THEM TOGETHER AT CONTROLLER. DO NOT GROUP LAl"iN AND SHRUB HEADS ON SAME STATION. 5. ELECTRICAL SUFFLY TO POINT OF CONNECTION SHALL BE BY OTHERS. CONTRACTOR SHALL PROVIDE "HARD l"ilRE" SPLICE INTO EXISTING JUNCTION BOX NEAR CONTROLLER LOCATION. F. AUTOtvlATIC CONTROL l"ilRING, I. INSTALL CONTROL l"ilRE5 IN GREY SGHEDULE ea PVC ELECTRICAL 5LEEVESl8" BELOY'I FINISH GRADE. 2. INSTALL CONTROL l"llRE SLEEVES, IRRIGATION MAINS AND LATERALS IN COMMON TRENCHES l"iHEREVER POSSIBLE. 5. INSTALL CONTROL l"ilRES SLEEVES TO SIDE OF MAINLINE l"iHERE POSSIBLE. l"ilRES SHALL BE A MINIMUM OF I" FROM ANY FIFE OR FITTING EXCEPT AT TERMINAL POINTS. FROVIDE LOOPED SLACK AT VALVES AND SNAKE l"llRES IN TRENCH TO ALLOY'! FOR CONTRACTION OF l"ilRE. TIE Y'IIRE IN BUNDLES AT 10' INTERVALS Y'IITH PLASTIC ELECTRICAL TAFE. 4. Y'IIRE 5FLIGE5 l"IILL BE ALLOY'IED ONLY ON RUNS MORE THAN 500 FEET. CRIMP l"IIRE5 TOGETHER l",ITH APPROVED V',IRE CONNECTOR, SEAL CONNECTION AND l"iRAF l",ITH ELECTRIC TAFE. 5. PROVIDE SEPARATE SLEEVING FROM IRRIGATION LINES FOR CONTROL V',IRE5 BENEATH PAVEMENT, ETG. ADL itc PLANNING ----!!!"'t'L ASSOCIATES -----!!!;l~i;;;L. 5.1 TESTING AND INSPECTION A. DO NOT ALLOY-I OR GAUSE ANY OF V',ORK OF THIS SECTION TO BE COVERED UP OR ENCLOSED UNTIL TEST HAS BEEN OBSERVED AND APPROVED BY LANDSCAPE ARCHITECT. REQUEST PRESENCE OF LANDSCAPE ARCHITECT AT LEAST THREE (5) MRKING DAYS IN ADVANCE OF TESTING. B. FLUSHING OF PIPE, BEFORE BACKFILLING MAINLINE, l"IITH CONTROL VALVES PLACED BUT BEFORE LATERAL LINES ARE CONNECTED, COMPLETELY FLUSH AND TEST MAINLINE. I. REPAIR LEAKS. 2. FLUSH OUT EACH SECTION OF LATERAL PIPE BEFORE SPRINKLER HEADS ARE ATTACHED. G. TESTING, I. MAKE NECESSARY PROVISIONS TO THOROUGHLY BLEED LINE OF AIR AND DEBRIS. 2. AFTER VALVES HAVE BEEN INSTALLED, l"IHEN Y'IELDED PLASTIC JOINTS HAVE CURED FOR AT LEAST 24 HOURS, TEST MAIN Y,,ATER LINES FOR LEAKS AT PRESSURE OF 125 PSI FOR PERIOD OF FOUR HOURS, V',ITH COUPLINGS EXPOSED AND FIFE 5EGTION5 GENTERLOADED Y'IITH SUFFICIENT AMOUNT OF BACKFILL TO PREVENT ARCHING OR SLIPPING UNDER PRESSURE. LATERAL LINES SHALL BE TESTED, l"ilTH RISERS GAPPED, FOR Tl"lO HOURS UNDER NORMAL STATIC PRESSURE. 5. PROVIDE REQUIRED TESTING EQUIPMENT AND PERSONNEL. 4. REPAIR LEAKS, RETEST UNTIL ACCEPTANCE BY LANDSCAPE ARCHITECT. D. FINAL INSPECTION, GLEAN, ADJUST, BALANCE ALL 5Y5TEM5. VERIFY, A. HEADS ARE PROPERLY ADJUSTED FOR RADIUS AND ARC, OF COVERAGE; El. INSTALLED SYSTEM IS l"iORKABLE, GLEAN, EFFICIENT. 5.8 INSTRUCTIONS A. ATTACH TYPEY'IRITTEN LEGEND INSIDE EACH CONTROLLER DOOR, 5TATIN6 AREAS COVERED BY EACH VALVE. El. AFTER SYSTEM HAS BEEN COMPLETED, INSPECTED, AND APPROVED INSTRUCT OY'INER OR HIS MAINTENANCE PERSONNEL IN OPERATION AND MAINTENANCE OF SYSTEM. 5."i MAINTENANCE MAINTAIN SYSTEM FOR PERIOD INDICATED IN IRRIGATION NOTES, OR LENGTH OF PLANTING MAINTENANCE PERIOD, l"lHIGHEVER IS GREATER. END OF SECTION • • •• • .. Call: TOLL FREE 1-800 422-4133 Tl"iO l"iORKING DAYS BEFORE YOU DIG "AS-BUILT EXP. REVIEWED BY: INSPECTOR ----------------+-----+----+----+----IRRl6ATION SPECIFICATIONS " DATE DATE ----------------+---+--~.--~---! LO RESIDENCE CARLSBAD, CA 92008 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS LAND PLANNING LANDSCAPE ARCHITECTURE 2979 STATE STREET SUITE "c" C A R L S B A D, C A. 9 2 O O 8 (7 60) 7 29-e 637 FAX: t;l 60) 7 29-8324 DATE: "i-12-lb =--=---+-___ -=-~~-=-======~----------+---+-----+--+---II APPROVED. ~.\ 0v t:lki\t PLANNING JOB NO.: 21511 ------------------ SCALE: ------------- DRAWN BY: DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL f--~ -----------~---< OTHER APPROVAL CITY APPROVAL DWN BY: __ _ CHKD BY:_ RVWD BY: PROJECT NO. HMP 16-01 DRAWING NO. 490-IL D.G. FATH ----, NEV-. SLOPE PLANTING ---, UNDISTURBED AREA*--~ PROPERTY LINE V-.EST SLOPE PLANTING---.. j UNDER6ROUND v-.A TER 5TORA6E FER CIVIL FLANS. SECTION C LINED BIO-FILTRATION BASIN PLANTED V-.ITH LEYMU5 CONDENSATUS 'CANYON PRINCE' AND JUNCAS FATENS PER CIVIL FLANS. PLANTING I ' ' UNDISTURBED AREA*---· LEGEND -TREES: 5Ev-.ER EASEMENT 5YM #, BOTANICAL NAME, COMMON NAME, SIZE, ~ .... 0 . -. . 0 - - Q 0 --GUERGUS A5RIFOLIA GOAST LIVE OAK 4b"60X -------- GERGIDIUM 'DESERT MUSEUM' PALO VERDE 48" eox ------ ---6EIJERA PARVIFLORA AUSTRALIAN il'IILLOil'I :24" BOX LA6ERSTROEMIA INDIGA CRAPE MYRTLE 15 6AL. -·--·-··--- LA5ERSTROEMIA HYBRIDS CRAPE MYRTLE 15 c,,AL. PODOGARPUS MAGROPHYLLUS JAPANESE YEil'I 15 c,,AL. .... -----·-CITRUS SP. CITRUS VARIETIES 15 c,,AL. UNDISTURBED AREA NOTE: QTY, REMARKS, I DOUBLE STAKE I DOUBLE STAKE 2 DOU6LE STAKE 5 DOUBLE STAKE 5 DOUBLE STAKE 4 DOUBLE STAKE ----- 5 DOUBLE STAKE UNDISTURBED AREAS TO RECEIVE SUPPLEMENTAL FLANTIN6 BY OV-.NER, V-.HICH INCLUDES A COLLECTION OF NATIVE AND DROUGHT TOLERANT PLANTS. PLANTING LEGEND -HYDROSEED Jv!IX: --- 5YM #, MIX, MANUFACTURE, AMOUNT, REMARKS, ORNAMENTAL LOii'! <,,ROil'IIN6 FOR MEADOf"I (SE!: 1----UTILITY EASEMENT L STREET Rl6HT OF V-.AY ' PLANTING LEGEND -SHRUBS: BOTANICAL NAME, PHORMIUM TENN< 'ALISON BLACKMAN' "' ~ "' ~ CORDYLINE 'DE51c,,N-A-LINE COMMON NAME, NEf"I ZEALAND FL.A!< 'DElc,,N-A-LINE' CORDYLINE t> t> ~ t> ! 6Ur<6UND'T'' _s __ ~"-;------------------+------------ @ Ml5CANTHU5 5. MORNINc,, L.lc,,HT MORNING LIGHT MAIDEN GRASS ----- ------LOMANDRA LON61FOLIA 'BREEZE' Df"IARF MAT RUSH 0f-------AGAVE 'il'IEBERI' il'IEBER5 A5AVE 0 . YUCCA FILAMENT05A i 'BRIGHT ED5E' ' I I I I I f I i 11' I! i I I PUNIGA 6-RANATU!vl 'NANA' ADAM'S NEEDLE Df"IARF POMl:GRANA TE SIZE, QTY, SPACING, REMARKS, 5GAL 21 PER FLAN TBD I GAL 444 24" o.c. TBD -- I GAL 14 PER PLAN TBD I GAL 44 24" O.C,, TBD 5GAL 2 PER FLAN TBD I GAL q PER PLAN I TBD ' I 5AL 45 24" o.c TBD '141 /' t J ~I----,---'-HE~B GARDEN -BY OV-.NER 11 I I 11 I . - I I ~c· I • . ' • --CONC. , D-0:f«:,K 'l I 11 \I 11 'I -l PLANTING LEGEND -NEV'i SLOPE: -DESCRIPTION, AREA TO CONSIST OF Fq>RMAL AND INFoRMAL SROUPINS5 OF THE FOLLOil'IINS PLANTl, BOTANICAL NAME, COMl"'ON NAME, SIZE, PHORMIUM TENAX ' ALISON BLACKMAN' NEIi', iEALAND FLA!< 5 GAL. CORDYLINE 'DESISN-A-LINE BURGUNDY' 'DEs1lN-A-LINE' coRDYLINE I 6AL. KNIPHOFIA UVARIA RED HOT POKER I GAL. PIT05PORLM TOBRIA Moes! ORANGE 5 GAL. MISCANTHUS 5. MORNINS Llc,,HT MORNINS LIGHT I 6AL. MAIDEN SRA55 f"IESTRINSIA FRLITICOSA COA5r ROSEMARY I GAL. LOMANDRA LONSIFOLIA 'BREEZE' Df"IARF MAT RUSH I GAL. ASAVE PARRYI VAR. 'TRUNCATA ARTICHOKE AGAVE I GAL. Ac,,AVE 'f"IEBERI' f"IEBE~ ASAVE 5 GAL. YUCGA FILAMENTOSA ADA~'5 NEEDLE I GAL. 'BRISHT EDSE' PUNIC.A SRANATUM 'NANA' ' I GAL. Df"IARF POME6RANA TE I SALVIA CLEVELAMDII CLEVELAND 5A6E I GAL. R05EMARINU5 OFFICINALL.15 ROsEi-1ARY I 6AL. LAVANDULA ANSU5TIFOLIA l:NSLl5H LAVENDER I GAL THYMUS YUL.SARIS COMMON THYME I GAL. MUHLENBERSIA CAPILLARIS PINK MUHLY I GAL. MYOFORUM PARVIFOLIUM 'PUTA CREEK' MYOPORUM FLATS. I NOTE, LOCATION AND 5ROUPIN65 OF ALL NEf"l 5LOPE PLANTS LISTED ABOVE ARE TOO BE DETERMINED ON-SITE. QUANTITY, 22 35 35 25 65 42 10 38 22 30 18 33 28 35 30 20 J □ r 7 r LAVANDULA SP. LAVENDER CALIFORNIA NATIVE GARDEN: 0 CEANOTHU5 'DARK STAR' DARK STAR CEANOTHU5 @ EPILOBIUM CALIFORNICUM 0 MIMULU5 PUNICEU5 >: >: >: ARCT05TAFHYL05 DEN51FLORA >: >: >: 'EMERALD CARPET' \ .I DUDLl:YA HASSEi ' ' COTONEA5TER AFICULATU5 I ffi CARFENTERIA CALIFORNICA 'ELIZAl:ETH' GROUND COVER: -, i * LANTANA MONTEVIDEN515 I FESTUGA GLAUGA TURF AREA: ....... ::•:// .... : TURF CALIFORNIA FUCHSIA Rl:D MONKEYFLOll'IER CARFl:T MANZANITA SANTA CATALINA LIVE-FOREVER - CRANBERRY GOTONEA5Tl:R ELIZABl:TH BUSH ANl:MONE TRAIL.INS LANTANA BLUE FESCUE TBD I GAL SGAL I GAL I 5AL I GAL FLAT I SAL S SAL I SAL FLATS SEED/ SOD PLANTING LEGEND -V'iEST SLOPE: ~ Dl:SCRIPTION, AREA TO CONSIST OF FORMAL AND INFORMAL ~ SROUPINS5 OF THE FOLLOf"IINc,, PLANTS, SPACING/ REMARKS, BOTANICAL NAME, COMMON NAME, 3' O.C. 24" O.C. 5011 O.C.. 3' O.C. 24" O.C. 30" o.c. 24111 O.G. 24" o.c. 3' o.c. 9011 o.c.. 24" o.c. B011 O.C.. 24" O.C. 30" O.C. 24' O.C. 24' O.C. 18" O.C. THROUGHOUT BAGCHARl5 FILULARIS MYOFORUM PARVIFOLIUM 'PUTA CREEK' ARCT05TAPHYL05 DEN51FLORA 'EMERALD CARPET' COYOTE BRUSH MYOPORUM CARPET MANZANITA NOTE, LOCATION AND 5ROUPINS5 OF ALL il'IE5T SLOP!: PLANTS LISTED ABOVI: ARI: TOO BE DETERMINl:D ON-SITE. PLANTING LEGEND -BASIN: 1 ll_L_L DESCRIPTION, AREA TO GON515T OF FORMAL AND INFORMAL [[[[[[ SROUPINS5 OF THE FOLLOf"IIN5 PLANTS, BOTANICAL NAME, LEYMU5 CONDEN5ATU5 ' CANYON PRINCE' JUNCU5 PA TENS COMMON NAME, CANYON FRINGE f"IILD RYE CALIFORNIA SRAY RUSH NOTE, LOCATION AND SROUPIN55 OF ALL BASIN PL.ANTS LISTED AeOVE ARE TOO BE DETERMINED ON-SITE. 190 5 s 11 IS q;i 2q 1 88 101 SIZE, FLATS. FLATS. 24" o.c.. PER PLAN FER PLAN PER PLAN 2411 O.G. 18" o.c. 90" o.c. PER PLAN 48" o.c. PER PLAN QUANTITY, I GAL. 65 SIZE, QUANTITY, I GAL. 60 I GAL. 45 TBD TBD TBD TBD TBD TBD TBD - TBD TBD TBD I SPACING/ REMARKS, 18" O.C. THROUGHOUT 18" O.C. THROU6HOUT 6' O.C. SPACIN6/ REMARKS, 30" o.c. "AS-BUILT " Call: TOLL FREE 1-800 422-4133 REVIEWED BY: EXP. DATE NATIVE MIX 5o5 SEEDS 55 LB5. PER AC.REI PLANTIN5 5PEGIFIGATION 5.6, SHEET L-1) HYDROSEED NOTES: I) ORNAMENTAL LOV'I 6ROV-.ING NATIVE MIX SHALL BE APPLIED TO THE OPEN MEADOV-. AREA. 2) BASIC NATIVE EROSION CONTROL MIX SHALL BE APPLIED TO ALL SLOPED AREAS ONSITE. 3) IN AREAS HYDR05EED 15 NOT SUFFICIENT OR F0551SLE, HAND SEEDING V-.ILL BE CONDUCTED. 4) HYDROSEED SLURRY V-.ILL BE APPLIED IN TV-.O STAGES, V-.ITH THE SECOND APPLICATION IMMEDIATELY FOLLOV-.ING THE FIRST TO ENSURE EVEN DISTRIBUTION IN ALL AREAS. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS ADL PLANNING --- ASSOCIATES __ LAND PLANNING LANDSCAPE ARCHITECTURE 2979 STATE: STREET SUITE "C" C A R L S B A D, C A. 9 2 0 0 8 (7 60) 729-8 637 FAX: (76 0)7 29 -83 2-4 DATE, '1-12-16 JOB NO., 21511 SCALE: DRAWN BY: DATE INITIAL ENGINEER OF WORK TV-.O V-.ORKING DAYS BEFORE YOU Dl6 INSPECTOR -DATE f-----t-------< ~E:ETJ. I CITY OF CARLSBAD ·1 SHEETS I L..? PLANNING DIVISION 1 -----+----+---+------------··----- DATE INITIAL DATE INITIAL REVISION DESCRIPTION ~--t-- CITY APPROVAL OTHER APPROVAL PLANTING PLAN AND LEGEND LO RESIDENCE CARLSBAD, CA 92008 APPROVED PLANNING DWN BY: CHKD BY: RVWD BY:_ wl qc t:i~tr =1 I -PROJECT NO. __ -:;:_;j L__f:1 M fJ_ 1 6-01 _j DRAWING NO. 490-IL ~----~ SLOPE 2 2 f--~ ,.1,,....,.,--_'J,~----G e, @' ~ .__,.__.-I.~ -0 ~~~.~~~)~ -+.+------l® -----© ·----0 0 ROOTBALL, 5ET C,ROY'lN I" ASOV!= GRADE @_) FINISH GRADE ® FERTILIZER TABLET PER SOILS REPORT 0 PLAC.E ROOTBALL OVER NATIV!= 5UBGRADE @ 2" BASIN BERM FOR SHRUBS 4" BASIN BERM FOR TREES © LAYER OF MULC.H (SEE FLANTING SPEC.IFIC.ATIONS FOR DEPTH) MAINTAIN 5" FROM TRUNK G) PLANTIN5 HOLE -2 TIMES C.ONTAINER Y'llDTH ® C.LASS A TOPSOIL BACKFILL 0 ROOTBALL, SET C.ROl"<N I" ABOV!= GRADE @_) 2" BASIN BERM FOR SHRUBS 4" BASIN BERM FOR TREES ® FINISH GRADE 0 FERTILIZER TABLET PER SOILS REPORT ® PLACE ROOTBALL OVER NATIV!= 5UEGRADE ~ © 2X C.ONTAINER DIA. (12" MIN. FOR LINERS) G) AMENDED BACKFILL (5EE SPEC.IFIC,ATIONS) ® C,ONTAINER DEPTH (12" MIN. FOR LINERS) 0_) 5" LAYER OF MULc.H, MAINTAIN 5" C.LEAR OF SHRUB BASE (@2% SLOPE (AY'lAY FROM TRI.INK) 0 0 0 a I ' I i . ' ' ! --------0 EXSITING SUEGRADE 0 FINISHED o;RADE AMENDED PLANTING BAC.KFILL 0 4" MULC.H LAYER INSTALLED PER PLANTING NOTES BEFORE PLANTING. AND SFEC.IFIC.ATIONS. 0 PLANT TYPE ANO 5FAC.ING ROOTBALL SLIGHTLY HIGHER THAN FINISHED o;RADE. AS SFEC.IFIED ON FLANS. • SEE NOTE 2q 4 50 THIS SHEET N.T.S. @SLOPE PLANTING N.t.s. @GROUNDGOVER PLANTING PLANTING NOTES I. THE PLANTING FLANS ARE DIA6RAMMATIC. ALL PLANTIN6 LOCATIONS ARE APPROXIMATE. PLANT SYMBOLS TAKE PRECEDENCE OVER PLANT QUANTITIES. QUANTITIES SHO)IIIN ON THE PLANTIN6 PLAN ARE APPROXIMATE AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY. CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT OF DISCREPANCIES BET)IIIEEN THE QUANTITIES AND SYMBOLS SHO)IIIN. 2. ALL )IIIORK )IIIILL BE IN ACCORDANCE )IIIITH THE REQUIREMENTS OF THE 60YERNIN6 A6ENCIES, (CITY OF CARLSBAD). 5. CONTRACTOR SHALL CONFIRM ALL LOCAL PERMITTING AND Sl6N-OFF REQUIREMENTS AND PROVIDE EVIDENCE TO O)IIINER PRIOR TO INITIATION OF ANY AND ALL SITE )IIIORK. 4. CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR )IIIITH ALL SITE CONDITIONS AND CONFIRM CONSTRUCTION TIMIN6 )IIIITH 6ENERAL CONTRACTOR PRIOR TO INITIATION OF ANY AND ALL SITE )IIIQRK. 5. CONTRACTOR SHALL NOTIFY O)IIINER'S REPRESENTATIVE OF ANY DISCREPANCIES IN THE EXISTING CONDITIONS OR )IIIITHIN THE PLANS PRIOR TO BE6INNIN6 )IIIORK. 6. CONTRACTOR SHALL CONFIRM THE LOCATION AND DEPTH OF ALL SITE UTILITIES PRIOR TO CONSTRUCTION. ALL )IIIORK SHALL BE PREFORMED IN A MANNER )IIIHICH )IIIILL AVOID POSSIBLE DAMA6E TO UTILITIES. HAND EXCAVATE AS REQUIRED. NOTIFY O)IIINER'S REPRESENTATIVE OF ANY DISCREPANCIES IMMEDIATELY. 1. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY REPAIRS MADE NECESSARY THROU6H THE ACTIONS OR NE6Ll6ENCE OF HIS CRE)III. B. ALL ROCKS AND DEBRIS THREE (B") AND LARGER SHALL BE REMOVED FROM PLANTING AREAS AND FROM THE SITE. 'I. PRIOR TO PLANTIN6, ALL IRRIGATION SYSTEMS SHALL BE FULLY OPERATIONAL AND ALL FLANTIN6 AREAS SHALL BE THOROU6HLY )IIIATERED. 10. PLANT MATERIAL MAY BE REJECTED AT ANY TIME BY THE O)IIINER'S REPRESENTATIVE DUE TO CONDITION, FORM OR DAMAGE BEFORE OR AFTER PLANTING. 11. ALL TREES )IIIITHIN 10' OR LESS OF HARDSCAPE AREAS, ()IIIALLS, CURBS, ROADS, BRO)III DITCHES, DRAINA6E STRUCTURES, ETC) SHALL BE INSTALLED )IIIITH A 24" MIN. ROOT BARRIER DEPTH. ROOT BARRIER SHALL BE INSTALLED PARALLEL TO HARDSCAPE SURFACE FOR A DISTANCE OF 10' FROM THE CENTER LINE OF THE TREE TRUNK IN BOTH DIRECTIONS, OR AS INDICATED ON PLAN. ROOT BARRIER TO BE MF6 BY 'BIO-BARRIER' OR APPROVED EQUAL. BARRIERS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS 12. TREES SHOULD BE LOCATED NO CLOSER THAN FIVE FEET FROM ANY DRAINA6E FLO)III LINE, SE)IIIER LINE, )IIIATER LINE, 6AS LINE, OR ELECTRICAL CONDUIT. 15. CONTRACTOR SHALL IMMEDIATELY UPON THE A)IIIARD OF THE CONTRACT, ORDER, LOCATE AND PURCHASE (OR HAYE HELD) ALL PLANT MATERIAL REQUIRED BY THESE PLANS AND SPECIFICATIONS. 14. PLANTIN6 BEDS SHALL HAYE FINISHED 6RADES SMOOTHED TO ELIMINATE PUDDLIN6 OR STANDIN6 )IIIATER. CONTRACTOR SHALL MAINTAIN A MINIMUM 2% DRAINA6E A)IIIAY FROM BUILDIN6S AND PAVIN6 INTO DRAINA6E STRUCTURES OR TO STREET (SEE EN61NEER'S 6RADIN6 AND DRAINA6E PLANS). CONTRACTOR SHALL NOTIFY O)IIINER IMMEDIATELY OF ANY CONFLICTS IN MAINTAININ6 DRAINA6E. 15. SEE EN6INEER'S PLAN FOR LAYOUT OF ALL CURBS, )IIIALLS, RETAININ6 )IIIALLS, UTILITIES, SITE 6RADIN6 AND DRAINA6E. SEE ARCHITECT'S PLAN FOR LOCATION OF ALL BUILDIN6S. 16. ALL PLANTIN6 SHALL BE 6UARANTEED FOR A MINIMUM OF '10 DAYS AFTER ACCEPTANCE OF INSTALLATION BY O)IIINER. 11. SHRUB AND 6ROUNDCOVER MASS QUANTITIES ARE SHO)IIIN ON PLANS. UNDERPLANT ALL TREES )IIIITH THE ADJACENT SHRUB AND/OR 6ROUNDCOVER AS INDICATED BY THE PLANS. MASS PLANTINGS SHALL BE INSTALLED )IIIITH TRIAN6ULAR SPACIN6. PLANT 6ROUNDCOVERS TO V>IITHIN 12" OF TREE TRUNKS OR SHRUB STEMS. 18. PRIOR TO PLANTIN6, IRRl6ATE ALL PLANTIN6 AREAS NORMALLY FOR T)IIIQ V>IEEKS TO GERMINATE )IIIEEDS. APPLY CONTACT HERBICIDE ("ROUND-UP", OR APPROVED EQUAL) TO V>IEEDS ONLY PER MANUFACTURER'S RECOMMENDATIONS. REPEAT PROCESS IF V>IEEDS PERSIST. l'I. TREE TRUNK PROTECTORS SHALL BE INSTALLED AT ALL TREES LOCATED IN LA)IIIN AREAS. 20.PLANTING TABLETS SHALL BE 6RO-PO)IIIER PLANTIN6 TABLETS 12-8-8 (12 MONTH SLO)III RELEASE FORMULATION). 21. ALL SHRUB BEDS SHALL HAVE A 5 INCH THICK MULCH LAYER. "MULCH" SHALL BE BARK MULCH FROM EITHER SHREDDED FIR OR SHREDDED CEDAR. MULCH SHALL BE FREE OF STICKS, STONES, CLAY, PAPER, PLASTIC OR OTHER FOREl6N MATERIAL. CONTRACTOR SHALL SUBMIT SAMPLE TO O)IIINER'S REPRESENTATIVE FOR APPROVAL PRIOR TO INSTALLATION. 22. ALL PLANT MATERIAL SHALL MEET MINIMUM STANDARDS SET BY THE AMERICAN ASSOCIATION OF NURSERYMAN AND THE CITY. 2B. TREE STAKES ARE NOT TO COME INTO CONTACT )IIIITH THE TREES, AND SHALL BE INSTALLED ON THE )IIIIND)IIIARD SIDE. 24. SOIL TEST SHALL BE PERFORMED BY A SOIL TESTINC? LABORATORY. THE TEST SHALL INDIC.ATE BUT NOT BE LIMITED TO THE FOLLO!"<ING, A oRo;ANIC. MATTER C.ONTENT B. N.P.K. C..PH D. ED E. SOIL TEXT1JRE (SILT, C.LAY, SAND) F. REC,OMMENDATIONS FOR AMENDMENTS, LEAC.HINC?, AND MAINTENANC.E THE RESULTS AND REC.OMMENDATIONS FROM THE SOIL TESTING LABORATORY SHALL BE SUBMITTED TO AND AFPROV!=D BY THE Ol"<NER'S REPRESENTATIVE. THE APPROVED RECOMMENDATIONS FOR AMENDMENTS AND BACKFILL SHALL BE INC.ORFORATED INTO THE LANDSC.APE FLANS PRIOR TO THE INSTALLATION OF IRRIGATION OR PLANTIN5 AND SHALL ElEC.OME PART OF THE APPROVED PLANS. POST PLANTING FERTILIZATION SHALL BE PERFORMED BY C,ONTRACTOR AT 50, bO, AND qo DAYS AFTER PLANTINC?. 25. FOR LANDSC.APE INSTALLATIONS, C.OMPOST AT A RATE OF A MINIMUM OF FOUR C.UEllC, YARDS FER IPOO SQUARE FEET OF PERMEABLE AREA SHALL BE INC.ORPORATED TO A DEPTH OF SIX INC.HES INTO THE SOIL. SOILS Y,,ITH GREATER THAN t,% ORGANIC. MATTER IN THE TOP b INC.HES OF THE SOIL ARE EXEMPT FROM ADDIN5 C.OMPOST AND TILLING, 26. PRIOR TO PLANTING OF ANY MATERIALS, C,OMPAC.TED SOILS SHALL ElE TRANSFORMED TO A FRIABLE C.ONDITION. ON ENGINEERED SLOPES ONLY AMENDED PLANTIN6 HOLES NEED MEET THE REQUIREMENT. 21. SOIL AMENDMENTS SHALL BE INC.ORFORATED AC.C.ORDIN5 TO THE REC.OMMENDATIONS OF THE SOIL ANALYSIS REPORT AND Y,,HAT 15 APPROPRIATE FOR THE PLANTS 5ELEC.TED. 28. THE AFFLIC.ATION OF ORGANIC. MULC.H MATERIALS MADE FROM REC.YC.LED OR POST-C.ONSUMER MATERIALS SHALL TAKE PREC.EDENC.E OVER INORGANIC. MATERIALS UNLESS REC.YC.LED OR POST-C.ONSUMER ORGANIC. FRODUC.TS ARE NOT LOC.ALLY AVAILABLE. 2q, THE FRONT AND REAR OF ALL PLANTINC? PITS ON SLOPES SHALL BE GRADED TO A MAXIMUM 1,1 SLOPE. 50. EROSION C.ONTROL FABRIC. SHALL ElE INSTALLED ON ALL SLOPES !'<HILE NEY'< PLANTING ESTABLISH. ADL ,,15 PLANNING ---_i!tLl~ !ll!e!l "l:: ASSOCIATES ====:l'llllll~it LAND PLANNING U\NDSCAPE ARCHITECTURE -- 2979 STATE STREET SUITE "C" C A R L S B A D, C A. 9 2 O O 8 (760)72 9-8 SJ 7 FAX:(760)7 29-8J24 N.T.S. ffi PREVAILING Y,,IND AXIS PARALLEL TO STAKES 2" DIA 10' PINE LODGE POLE STAKE TREE TIES (5) FINISH GRADE ®----G),~ ® 0 ® ROOTBALL (SEE PLAN FOR SIZE, SET C.RO!"<N I" ABOV!= GRADE) FERTILIZER TABLET PER ~--1 B 0 G) ® SFEC.IFIC.ATIONS AND SOILS REPORT b" Y'lATER BASIN i 2" LAYER OF MULC,H MAINTAIN 5" C.LEAR OF TRUNK AMENDED BAC.KFILL 2X C.ONTAINER SIZE AERATION TUBE -4" FERF. PVC. PIPE i"I/ GRATE C.AP. Y'lRAP PIPE VII/ FILTER FABRIC., I PER 15 GAL 2 FER 24" BOX AND LARGER D TREE STAKING SLOPE PLANTING NOTES SLOPES b,i OR STEEPER REQUIRING EROSION C.ONTROL MEASURES AS SFEC.IFIED HEREIN SHALL BE TREATED l"<ITH ONE OR MORE OF THE FOLLO!"<IN6 PLANTIN6 STANDARD. A. STANDARD 01 -C,OV!=R C,ROP5/REINFORc.ED STRAY'l MATTIN5. C.OVER C.ROP5 SHALL BE A SEED MIX TYFIC.ALL Y MADE UP OF QUIC.K GER.MINA TING AND FAST C.OVERINC? GRASSES, C.LOVERS, AND/OR l"<ILD FLOY',ERS, SUElMIT THE SFEC.IFIC. SEED MIX FOR C.ITY APPROVED PRIOR TO APPLIC.ATION. THE C.OVER C.ROP SHALL BE APPLIED AT A RATE AND MANNER 5UFFIC.IENT TO PROVIDE qo% C.OVERAGE Y,,ITHIN THIRTY (50) DAYS. TYPE OF REINFORC.ED STRAY'< MATTING SHALL BE APPROVED BY THE C.ITY AND STAKED TO THE SLOPE AS REC.OMMENDED ElY THE MANUFAC.TURER. REINFORc.ED STRAY'< MATTINC? SHALL BE REQUIRED !'<HEN PLANTING OC.C.URS ElETY',EEN AUo;UST 15 AND APRIL 15. THE C.OVER C.ROP AND/OR REINFORc.ED STRAY', MAT SHALL BE USED THE REMAINDER OF THE YEAR. B. Standard #2 -IS-ROUND COVER, ONE HUNDRED PERC.ENT (100%) OF THE AREA SHALL BE PLANTED Y,,ITH A GROUND C.OVER KNOl"<N TO HAVE EXC.ELLENT SOIL EllNDING C.HARAC.TERISTIC.S (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPAC.ED TO PROVIDE FULL C.OVERAGE Y'llTHIN ONE YEAR). C,. STANDARD 05 -LOY'l 5HRUElS, LOY'< SPREADIN5 l"<OODY 5HRI.IBS (PLANTED FROM A MINIMUM OF 2-5/4" LINERS) SHALL C.OVER A MINIMUM OF SEVENTY PERC.ENT (10%) OF THE SLOPE FAC.E (AT MATURE SIZE.) D. STANDARD 04 -TREES AND/OR LARGE SHRUBS, THREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF I GALLON C,ONTAINER5) AT A MINIMUM RATE OF ONE /1) PER Tl"<O HUNDRED (200) 5al.lARE FEET. SLOPES -b ,I OR STEEPER AND, A 5' OR LESS IN VER.TIC.AL HEIGHT AND ARE ADJAC.ENT TO PUBLIC. Y'lALK5 OR STREETS REQUIRE AT MINIMUM STANDARD 01. El. 5' TO e,• IN VERTIC,AL HEIGHT REQUIRE STANDARDS OI (EROSION C,ONTROL MATTING SHALL BE INSTALLED IN LIEU OF A C.OVER C.ROP), 02 AND •5. C,. IN EXC.E55 OF e,• IN VERTIC.AL HEIGHT REQUIRE STANDARDS 01 (EROSION C.ONTROL MATTINC? SHALL BE INSTALLED IN LIEU OF A C.OVER C.ROP), 02, •B, AND 04. AREAS GRADED FLATTER THAN b, I REQUIRE STANDARDS OI (C.OVER C.ROF) l"<ITH TEMPORARY IRRIGATION Y,,HEN THEY HAVE ONE OR MORE OF THE FOLLOY,,INc,, C.ONDITIONS, A SHEET GRADED PADS NOT sc.HEDULED FOR IMPROVEMENT5 Y,,ITHIN b MONTHS OF C.OMFLETION OF RoUGH GRADINc,,. B. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE C.ITY. C,. IDENTIFIED ElY THE CITY AS HIGHLY VISIElLE AREAS TO THE PUElLIC. OR HAVE SPEC.IAL C.ONDITION5 THAT !'<ARRANT IMMEDIATE TREATMENT. Call: TOLL FREE 1-800 422-4133 REVIEWED BY, T)IIIO )IIIQRKIN6 DAYS BEFORE YOU Dl6 INSPECTOR "AS-BUILT EXP. " PLANTING> DETAILS AND NOTES N.T.S DATE DATE LO RESIDENCE CARLSBAD, CA 92008 ; ---------------+----+----+-·---,------- DATE; '1-12-16 ------ _+----+---+---+-----l IA _P_P_R_ov_E_o_~C..=-=--/1~("-~-.:c=~~----f~\ <=re 8\-.-1\- f---+---+------------------+---+----l-----l-----l , PLANNING JOB NO.; 21511 SCALE: DATE INITIAL APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS DRAWN BY: ENGINEER OF WORK REVISION DESCRIPTION f---o~-:-::-AiPP-:-~T-~:-~--l--0-:-,~-AiPP-~N-~:-:-~__, '-:. ~:;:t=~=g=s==i=~=: =~-[_ ~M-R-~JE~1 N%~ DRAWING NO. 490-IL LANDSC,AFE PLANTING 5FECIFIC,ATIONS -LAND¼APE YiORK I .I. RELATED DOOJMENT5 I.I.I. DRmlN55 AND ISENERAI. PROVISIONS Of C,ONTRACT, INC,LUDIN& ISENERAI. AND SUPPLEMENTARY CONDITIONS AND DIVISION I SPEC,IFIC,ATION SECTIONS, APPLY TO THIS SECTION. 1.12. C,ITY Of C,ARLSEADS LAND¼APE MANUAL. 12. SUMMARY 1.2.1. THIS SECTION INCLUDES PROVISIONS FOR THE FOLLOYilNS ITEMS, 12.1.1. TREES. 12.12. SHRl!BS. 1.2.1.:l. PLANTS. 12.1.4. ISROUNDGOVER. 12.15. SOIL AMENDMENTS. 1.2.1.o. FINISH ISRADINS. 1.2.1.1. MAINTENANCE PERIOD. 1.2.2. RELATED SEC,TIONS, THE FOLLOYilNS SEC, TIONS C,ONTAIN REGIUIREMENT5 ll!AT RELATE TO 122.1.. UNDERISl<OVND SFRINKLER SYSTEM 15 SPECIFIED IN DIVISION 2 SEC,TION, AS A RECLAIMED 11115 SECTION. YiATER IRRIISATION SYSTEM l.:l. GIUALITY ASSURANCE 1.3.1. THE CONTRACTOR SHALL SPECIALIZE IN LAND¼APE Y'IORK AND POSSESS ALL LICENSES AND FERMIT5 REGIUIRED TO PERFORM 111E YiORK INCLUDINS FEST CONTROL APPLIC,ATORS AND C-21 LAND¼AFINS LICENSES. 1132.1. ISENERAL, SHIP LAND¼APE MATERIALS Yillll C,ERTIFIC,ATES OF INSPECTION REQUIRED BY 1.32. SOURCE GIUALITY CONTROL, GOVERN INS AUTHORITIES. COMPLY Yillll REISULA TIONS APPLICABLE TO LAND¼AFE MATERIALS. 1.32.2. DO NOT MAKE SUB5Tl11JTIONS. IF SPEGIFIED LAND¼AFE MATERIAL 15 NOT OBTAINABLE, SUBMIT PROOF OF NON-AVAILABILITY TO LAND¼APE ARCHITEC,T. LANDSCAPE ARCHITECT SHALL SPECIFY ALTERNATE MATERIAL. CITY INSPEC,TOR MUST APPROVE 5UE5Tl'TIJTIONS. 1.B.2.B. ANALYSIS AND STANDARDS, PACKAISE STANDARD PRODUCT5 Yillll MANUFAC,11JRERS CERTIFIED ANAL Y5I5. FOR Oll!ER MATERIALS, PROVIDE ANAL Y515 EY RECOISNIZED LAEORA TORY MADE IN AC,CORDANCE Yillll ME11!0D5 ESTABLISHED BY THE ASSOCIATION OF OFFICIAL 1.B.2.4. TREES, SHRUES, AND PLANT5, PROVIDE TREES, SHRl!ES, AND PLANT5 OF QUANTITY, AISRIGUL 11JRE CHEMl5T5, Y'IHEREYER AFFLIC,ABLE. SIZE, ISENIJS, SPECIES, AND VARIETY SHOYiN AND SC,HEDl/LED FOR LAND¼AFE YiORK AND COMF'L YING YilTH RECOMMENDATIONS AND REQUIREMENTS OF ANSI ZbO.I "AMERICAN STANDARD FOR tM<SERY STOCK'. PROVIDE HEAL THY, VIISOROUS 5TOGK, 5ROY'IN IN A REC05NIZED NURSERY IN ACC,ORDANCE YilTH GOOD HORTIC,UL 11JRAL PRACTIC,E AND FREE OF DISEASE, INSEC,T5, E66S, LARVAE, AND DEFEC,T5 SUCH AS KNOTS, SUN-SCALD, INJURIES, ABRASIONS, OR DISFIGUREMENT. 1.32.5. YiHERE FORMAL ARRANISEMENTS OR CONSECUTIVE ORDER OF TREES OR SHRl!ES ARE 1.3.2.b. SELECTION, ll!E LAND5C,AFE ARCHITECT MAY CHECK TREES AND SHRl!BS Elll!ER AT SHOViN, SELECT STOCK FOR UNIFORM HEIISHT AND SPREAD. PLACE OF 5ROITTH OR AT SITE BEFORE FLANTINS, FOR COMPLIANCE YilTH REQUIREMENTS FOR 5ENU5, SPECIES, VARIETY, SIZE, AND GUALITY. THE CONTRACTOR SHALL 51.JEMIT PHOTOGRAPHS TO LANDSCAPE ARCHITEC,T OF TYFIC,AL TREES (15 GAL. AND LARISER C,ONTAINER SIZES) FOR LAND¼AFE YiORK. LAND¼AFE ARCHITECT RETAINS RIISHT TO FURll!ER CHECK TREES AND 5HRUE5 FOR SIZE AND C,ONDITION OF BALLS AND ROOT SYSTEMS, INSECTS, INJURIES AND LATENT DEFECTS, AND TO RE-.EGT UNSATISFACTORY OR DEFECTIVE MATERIAL AT ANY TIME DURIN& PROISRf:55 OF YiORK. CONTRAC,TOR SHALL REMOVE REJEC,TED TREES OR SHRl!ES IMMEDIATELY FROM PROJECT SITE. 1.4. 5UEMITTAL5 1.4.1. ISENERAL, 51.JEMIT 111E FOLLOYilNS IN ACCORDANC,E YilTH C,ONDITIONS OF CONTRACT AND DIVISION I SPECIFIC,ATION SECTIONS. 1.4.2. PLANT AND MATERIAL C,ERTIFIC,ATION5, 1.42.1. CERTIFIC,ATE5 OF INSPECTION AS REQUIRED BY GOVERNMENTAL AUTHORITIES. 1.4.22. MANUFAC,11JRER'5 OR VENDORS CERTIFIED ANAL Y515 FOR SOIL AMENDMENT5 AND 1.4.2.3. LABEL DATA 5UE5TANTIATIN5 ll!AT PLANTS, TREES, SHRl!ES AND PLANTINS MATERIALS FERTILIZER MATERIALS. 1.4.2.4. SEED VENDOR'S CERTIFIED STATEMENT FOR EACH SEED MIXTURE REQUIRED, 5TATIN5 COMPLY YilTH SFEC,IFIED REQUIREMENTS. BOTANICAL AND COMMON NAME, FERCENTAISES BY YiEIISHT, AND FERCENTAISES OF PURITY, GERMINATION, AND YiEED SEED FOR EACH SEED SPECIES. 1.43. SOIL TESTINS, 1.4.o.l UPON C,OMFLETION OF GRADINS OPERATIONS, THE CONTRAC,TOR SHALL TAKE ONE REPRESENTATIVE SOIL SAMPLE FROM EACH DIFFERENT SOIL TYPE AND CONDITION FOR AISRICULTIJRAL SUITABILITY TESTINIS AT A DEFlll OF b" TO 12'. SOIL SAMPLES SHALL 1.4132. SOIL TEST SHALL BE PERFORMED 6Y A SOIL TESTINIS LABORATORY PRE-APPROVED BY REPRESENT A CROSS SECTION OF SOIL C,ONDITIONS PRESENT AT l1IE SITE. THE CITY. TESTS SHALL INDICATE ORISANIC, MATTER CONTENT; N, F, K; FH; Ee;, SOIL TEXTIJRE, RECOMMENDATIONS FOR AMENDMENT5, LEACHINS, HYDROSEEDINiS, SOD LAY'IN, SEED LAY'IN, AC,ID 1.4.:l.:l. SOIL TEST RESULT5 AND RECOMMENDATIONS OF l1IE LABORATORY SHALL BE 51.JEMITTED LOVINS PLANTS AND MAINTENANCE FERTILIZATION. TO THE C,ITY OF CARLSBAD INSFEC,TOR AND ll!E LANDSCAPE ARCHITEC,T FOR INCORPORATION INTO ll!E FLANS. TEST RESULTS MUST BE REYIEY'IED AND APPROVED PRIOR TO SOIL AMENDINS. 1.4.3.4. PRODUCTS SPEC,IFIED 6Y PRODUCT NAME EY THE SOILS TESTINS LAE IN THE RECOMMENDATIONS MAY BE SUE5Tl11JTED Yillll 'OR EQUAL" PRODUC,TS APPROVED BY ll!E OMRS REPRESENTATIVE. 1.5. DELIVERY, STORAISE AND HANDLING 1.5.1. PACKA<>ED MATERIALS, DELIVER PACKAGED MATERIALS IN CONTAINERS SHOYilNS YiEIISHT, ANALYSIS, AND NAME OF MANUFAC,TIJRER. FROTEC,T MATERIALS FROM DETERIORATION DURINS DELIVERY, AND YiHILE STORED AT SITE. 15.2. TREES AND SHRIJES, DO NOT PRUNE PRIOR TO DELIVERY UNLESS OlllERYilSE APPROVED EY LANDSCAPE ARCHITECT. DO NOT BEND OR EIND-TIE TREES OR SHRl!ES IN SUCH MANNER AS TO DAMAISE BARK, BREAK BRANCHES, OR DESTROY NATIJRAL SHAPE. PROVIDE PROTEC,TIYE COVERING DURINS DELIVERY. 1.5.3. DO NOT REMOVE C,0NTAINER-5ROY'IN STOGK FROM C,ONTAINERS UNTIL FLANTINS TIME. l.b. JOB C,ONDITIONS l.b.l. UTILITIES, DETERMINE LOC,ATION OF UNDERISROUND UTILITIES PRIOR TO THE INITIATION OF ANY Y'IORK. PERFORM ALL YiORK IN A MANNER YiHIC,H YilLL AVOID POSSIBLE DAMAISE TO UTILITIES. HAND EXCAVATE, AS REQUIRED. MAINTAIN GRADE STAKES SET BY Oll!ER5 UNTIL REMOVAL 15 MU11JALLY A&REED UPON EY PARTIES CONCERNED. 1.1. 5EGUENCIN5 AND ¼HEI:VLING 1.1.1. PLANTING TIME, PROC,EED Yillll, AND C,OMFLETE LAND¼APE YiORK AS RAPIDLY AS PORTIONS OF SITE 6EC,OME AVAILABLE. Y'IORK SHALL BE PERFORMED DURING THOSE PERIOD5 YiHEN YiEATHER AND SOIL e,QNDITIONS ARE SUITABLE IN ACCORDANC,E YilTH LOC,ALL Y ACC,EPTED HORTIC,UL 11JRAL PRAC,TIC,E. 1.1.2. COORDINATION Yillll GROIJNDC,OVERS , PLANT TREES AND 5HRIJE5 AFTER FINAL GRADES ARE AREAS AND PROMPTLY REFAIR DAMAISE TO GRO\JNDC,QYERS RE5ULTIN5 FROM PLANTING OPERATIONS. ESTABLISHED AND PRIOR TO PLANTINS OF iSROUNDCOYERS, UNLESS Oll!ERYilSE APPROVED BY LANDSCAPE ARCHITEC,T. IF PLANTINIS OF TREES AND SHRIJES QC,C,URS AFTER iSROUNDCOYER PROTEC,T GROUNDCOVER 1.8. SPEC,IAL PROJEC,T YiARRANTY 1.8.1. YiARRANTY LAYiNS AND GROUNDC,OVER5 ll!ROIJGH 5FECIFIED MAINTENANCE PERIOD, AND UNTIL FINAL ACC,EPT ANGE. 1.82. Y'IARRANTY SHRIJES FOR A PERIOD OF qo DAYS AFTER DATE OF FINAL ACC,EPTANCE. 1.8.:l. Y'IARRANTY TREES, FOR A PERIOD OF ONE YEAR AFTER DATE OF 5UE5TANTIAL COMPLETION, A5AIN5T DEFECTS INCLUDING DEAlll, FOOR 5ROY'ITH OR FORM. 1.8.4. REMOVE AND REPLACE TREES, SHRl!BS, OR OTHER PLANTS FOUND TO EE DEAD OR IN UNHEALTHY CONDITION DURINS YiARRANTY PERIOD. MAKE REPLACEMENTS YilTHIN 14 C,ALENDAR DAYS OF NOTIFIC,ATION. REPLACE TREES AND SHRIJES YiHIC,H ARE IN DOUBTFUL CONDITION AT END OF YiARRANTY FOR A FULL &ROVilNG SEASON. 1.85. ANOTHER Y'IARRANTY SITE OESERVATION VISIT t'ilLL BE CONDUCTED AT END OF EXTENDED PERIOD; UNLESS, IN OPINION OF LAND¼AFE ARCHITECT, IT 15 ADVISABLE TO EXTEND YiARRANTY PERIOD BE FURNISHED, AND PLANTED AS ORl&INALL Y SFEC,IFIED. YiARRANTY PERIOD, IF ANY, TO DETERMINE ACCEPTANC,E OR REJEGTION. REGUIRED REPLACEMENTS SHALL PART 2 -PROl)L\',15 2.1. SOIL AMENDMENTS 2.1.1. ORGANIC SOIL AMENDMENT SHALL BE A BLENDED COMMERCII\LL Y PROCESSED SOIL CONDITIONER C,ON515TIN5 Of AN OR6ANIC,-BA5ED C,ONDITIONE~ PREPARED BY MIXINIS A LIISHT, FRIABLE, SILIC,EOIJS MATERIAL YilTH NITROGEN-FORTIFIED, FINELY iSROUND BARK, YiOOD CHIPS AND/OR SAYi DUST. THE MATERIAL SHALL CONTAIN A LON5-LA5TIN5 FORM OF IRON AND SHALL BE YilLEUR-ELLIS "OR6ANO-LIFE" SOIL AMENDMENT OR APPROVED EGIUAL. 2.12. SARK MULCH, M\JLC,H SHALL BE EARTHY'IISE ECO-MLJLC,H, A5 MANUFACTIJRED BY A.J. ECOLOISY INDUSTRIES INC.I (blq) 144-oq42, 5UBMIT SAMPLE TO C,ITY INSFECTOR FOR APPROVAL PRIOR TO EULK DELIVERY TO S TE. 2.13. COMMERCIAL FERTILIZER. C,OMF'LETE FERTILIZER OF NEUTRAL C,HARACTER, PER ll!E SOIL TEST RECOMMENDATIONS. 2.1.4. PLANT TABLETS, 2.1.4.1. GROUNDCOYER, AGRIFORM 5-GRAM (20-10-5) BLUE CHIP TABLETS. 2.1.4.1. SHRl!ES AND TREES, AISRIFORM 21~RAM (20-10-5) BLUE C,HIP TABLETS. 2.15. IRON SULFATE, IRON SHALL BE EXFRESSED AS METALLIC-DERIVED FROM SULFATE-DEEP GREEN (FE504H20) A MINIMUM ANALYSIS OF 200 96 AND qe,3% RETAINED ON A 10 MESH ¼REEN. 2.1.o. GYPSUM, AISRICULTIJRAL GRADE GYPSUM SHALL BE A (C,AS04H20) C,ALC,IUM SULFATE q4_3 SHALL PASS A 50 MESH SCREEN. 2.2. PLANTINIS BACKFILL MIX 2.2.1. PLANTINIS BACKFILL SHALL BE A THOROU5HL Y BLENDED MIXTURE OF EXCAVATED SOIL FROM THE PITS AND SOIL AMENDMENTS AT l1IE RATE REC,OMMENDED IN THE SOIL TEST RESULTS. 2.:l. PLANT MA TERI AL 2.3.1. QUALITY, PROVIDE TREES, 5HRIJE5, AND OTHER PLANTS OF SIZE, 5ENU5, 5PEC,IE5, AND VARIETY SHOYiN AND ¼HEDULED FOR LAND¼APE YiORK AND C,OMPLYING Yillll RECOMMENDATIONS AND REQUIREMENTS OF ANSI Z60.I "AMERIC,AN STANDARD FOR NURSERY 5TOC,K." 2.3.2. C,ONTAINER 5TOC,K (I GAL., 5 GAL., 15 GAL., BOXES) SHALL HAYE BEEN GROY'IN IN CONTAINER FOR AT LEAST SIX MON1115, BUT NOT OVER TY'IO YEARS. NO CONTAINER PLANTS THAT HAYE C,RACKED OR BROKEN BALLS OF EARTH, MN TAKEN FROM THE C,QNTAINER, SHALL BE PLANTED, EXC,EPT UPON SPEc;IAL AFFROYAL. NO TREES YilTH DAMA5ED ROOTS OR BROKEN BALLS SHALL BE PLANTED. 2.:l.3. TREES, PROVIDE TREES OF HEIISHT AND YilDTH ¼HEDULED OR SHOY'IN AND Yillll BRANCHINS C,ONFIGURATION RECOMMENDED 6Y ANSI ZbO.I FOR TYPE AND 5FEC,IE5 REGUIRED,. UNLESS OTHERY'IISE 5FECIFIED QUAI-IT'ITIES SHALL BE RJRNISHED AS NEEDED TO COMPLETE MRK SHOY'IN ON DRAV'IINGS. PROVIDE 51N5LE STEM TREES EXCEPT YiHERE 5PEC,IAL FORMS ARE SHOYiN OR LISTED. 23.4. SHRl!BS, PROVIDE SHRl!BS OF l1IE HEIGHT AND YilDTH SHOY'IN OR LISTED REQUIRED BY ANSI ZbO.I FOR TYPE AND HEIGHT OF SHRIJE REGUIRED. 2.4. ISRO\JNDC,OVER MATERIALS 2.4.1. SEED, PROVIDE FRESH, C,LEAN, NEY'l<ROP SEED C,OMPLYINiS YilTH TOLERANGE FOR PURITY AND ISERMINATION ESTABLISHED BY OFFIC,IAL SEED ANALYSTS OF NORlll AMERICA. PROVIDE SEED MIXTURE COMPOSED OF SEED SPEC,IES, PROPORTIONS AND MINIMUM PERCENTA&ES OF PURITY, ISERMINATION, AND MAXIMUM FERCENTAISE OF YiEED SEED, AS 5FEC,IFIED IN l1IE 'SC,HEDULE OF SEED MIX11JRE5" INDICATED ON PLANS. 2.42. PROVIDE GROUND C,OVER PLANTS ESTABLISHED AND YiELL ROOTED IN FLAT REMOVABLE CONTAINERS AND Yillll NOT LESS ll!AN MINIMUM NUMBER AND LENGTH OF l<!JNNERS REGUIRED BY ANSI ZbO.I FOR l1IE POT SIZE SHOY'IN OR LISTED. 2.5. H'fDROSEED C,OMPONENTS AND ADDITIVES 2.5.1. MATERIALS, ALL MATERIALS SHALL BE STANDARD, APPROVED, FIRST iSRADE GUALITY AND IN PRIME C,ONDITION MN INSTALLED. ALL C,OMMERCIAL PROCESS OR PAC,KAiSING MATERIAL SHALL BE DELIVERED TO ll!E SITE IN l1IE ORIGINAL UNOPENED CONTAINERS BEARINS ll!E MANUFACTIJRER'S GUARANTEED ANALYSIS. 2.5.2. BINDER -AZ-TAC OR EGUAL. 253. C,ELLULOSE FIBER MULCH -YiEYERHAEUSER "SILVA-FIBER" OR EGUAL. 2.b. MISCELLANEOUS LAND5C,AFE MATERIALS 2.b.l. 5TAKIN5 MATERIAL, STAKES SHALL EE OF LODISEPOLE PINE. THESE SHALL BE STRAIGHT SHAFTS, SHAVED AND C,UT C,LEAN AND EARE OF BRANCHES AND 511JB5, OF UNIFORM ll!IC,KNESS Yillll A MINIMUM DIAMETER OF 2 INCHES, FREE OF LOOSE KNOTS, 5FLITS OR BENDS. STAKES SHALL BE NO LE55 ll!AN TEN (IO) FEET IN LENSTH. 2.b.2. TREE TIES, TREE TIES SHALL BE V.I.T. C,INCH-TIE OR APPROVED EQUAL. 2.b.3. GUY YilRES, 12 GAUISE iSALVANIZED YilRE. 2.b.4. &UY YilRE HOSE, 3/8" OR 5~6" X .Ob2" ITT POLYETHYLENE 11JBINIS BY YiARD MFG., tl14) 631-5055. 2.b5. ROOT BARRIERS, C,OPOL YMER FOL YPROP'l'LENE, INJEC,TION MOLDED, .000 THIC,KNESS ROOT BARRIER AS MANUFACTIJRED EY DEEP ROOT CORPORATION, (800) 45!l-1b68. USE MODEL UE 24-2 ADJACENT TO CURES AND PAVINS SURFACES. USE MODEL UE 3b-2 ADJACENT TO RETAININIS YiALLS AND EUILDINS FOOTIN55. PNtr S • EXl:GIITl()II 3.1. PREPARATION -ISENERAL 3.1.1. ALL ROCK AND OTHER 5ROITTH OR DEBRIS ACGUM\JLATED DURING THE DURATION Of ll!E PROJEC,T SHALL EE REMOVED FROM THE SITE. 3.1.2 iSRADINS AND SOIL PREPARATION Y'IORK SHALL BE PERFORMED ONLY DURINIS ll!E PERIOD MN BENEFIC,IAL AND OPTIMUM RESULTS MAY BE OBTAINED. IF l1IE MOl511JRE WNTENT OF l1IE SOIL SHOULD REACH 5UC,H A LEVEL ll!AT YiORKINIS IT YiOULD DESTROY SOIL 5TRIIC,11JRE, 5FREADIN5 AND 5RADIN5 OPERATIONS SHALL BE SUSPENDED UNTIL ll!E MOl511JRE CONTENT 15 INCREASED OR REDUCED TO ACC,EPTAELE LEVELS AND ll!E DESIRED RESULT5 ARE'LIKELY TO BE OBTAINED. B.I.B. ALL ¼ALED DIMENSIONS ARE APPROXIMATE. BEFORE PROCEEDING YilTH ANY YiORK, C,AREFULLY CHECK AND VERIFY ALL DIMENSIONS AND IMMEDIATELI!' INFORM THE LAND¼APE ARCHITECT OF ANY DISCREPANC,Y BETY'IEEN THE D!<mlN55 AND/OR 5PEC,lflC,ATION5 AND AC.11JAL C,ONDITIONS. 3.1.4. QUANTITIES FOR PLANT MATERIALS ARE SHOY'IN FOR C,ONYENIENC,E ONLY, AND NOT iSUARANTEED. C,HEC,K AND VERIFY C,OUNT AND SUPPLY SUfFIC,IENT NIJt'IBER TO FULFILL INTENT OF DRAY'IIN55. C,ERTIFY ANY CLARIFIC,ATION'S YilTH THE LANDSCAPE ARCHITECT. ADEGIUATELY STAKE, BARRICADE, AND PROTEC,T ALL IRRIGATION EQUIPMENT, MANHOLES, UTILITY LINES, AND OTHER EXl5TIN5 PROPERTY DURINIS ALL PHASES OF THE SOIL AMENDINS, PLANTINS AND GRADINS OPERATIONS. 3.1.5. CONTRACTOR SHALL SUPPLY SIGNED C,0PIE5 OF REQUIRED e,ERTIFIC,ATES, TRIP SLIPS, AND INVOIC,ES FOR SOIL PREPARATION MATERIALS, AND SHALL INVO[C,E SUe,H MATERIAL, e,QMPARINIS THE TOTAL GUANTITIES OF EACH MATERIAL FURNISHED AISAINST THE TOTAL AREA TO EACH OPERATION. IF l1IE MINIMUM SOIL PREPARATION RATES OF AFFLIC,ATION HAYE NOT BEEN MET, THE LAND¼AFE ARCHITEC,T YilLL REGUIRE AT NO COST TO OY'INER, THE DISTRIEUTION OF ADDITIONAL QUANTITIES OF THESE MATERIALS TO RJLFILL ll!E MINIMUM APPLIC,ATION REGUIREMENTS 5FEC,IFIED. 3.2. FINISH ISRADINS 32.1. FINISH ISRADING, FINISH GRADES SHALL BE AS INDle,ATED ON ll!E C,IVIL ENISINEER'S Di<mlN55 AND LANDSC,APE DRAY'IINGS. 322. FINISH GRADES SHALL BE MEASURED AS ll!E FINAL YiATER C,OMPACTED AND SETTLED SURFACE 5RADES; AND SHALL BE YilTHIN PLUS OR MINUS 0.1 FOOT OF ll!E SPOT ELEVATIONS AND GRADE LINES INDICATED ON THE DRAt'ilNIS. 3.2.:l. MOLDINS AND ROUNDINIS OF l1IE 5RADES SHALL BE PROVIDED AT ALL C,HANISES IN SLOPE YiHERE REQUIRED BY THE LANDSCAPE ARCHITEC,T. 3.2.4. ALL UNI:VLATIONS AND IRREGULARITIES IN THE FlcANTINS SURFAC,ES RESULTINIS FROM TILLAISE, ROTOTILLING AND ALL OTHER OPERATIONS SHALL BE LEVELED AND FLOATED OUT BEFORE PLANT INS OPERATIONS ARE INITIATED. 32.5. THE CONTRAC,TOR SHALL TAKE EVERY FREC,AUTION TO PROTEC,T AND AVOID DAMA5E TO SPRINKLER HEADS, IRRIGATION LINES, AND OTHER UNDERGROUND UTILITIES Dl/RIN& Hl5 ISRADING AND C,ONDITIONING OPERATIONS. 32.b. FINAL FINISH GRADES SHALL INSURE POSITIVE DRAINAISE OF THE SITE YilTH ALL SURFAC,E DRAINAISE AMY FROM BUILDINGS, YiALLS, AND TOY'IARD ROADY'IAYS, DRAINS AND C,ATC,H BASINS. B.2.1. FINISH &RADE SHALL MATC,H THOSE OF THE C,IVIL EN51NEER'5 DRAY'IINGS. FINAL ISRADES SHALL BE ACC,EPTABLE TO THE LANDSCAPE ARCHITECT BEFORE PLANTING OPERATIONS YilLL BE ALLOY'IED TO BEGIN. 3.3. PREPARATION FOR PLANTINS AREAS 3.:l.l. SOIL C,ONDITIONING, FERTILIZING i ROTOTILLINIS, AFTER THE PLANTINIS AREAS HAYE BEEN ISRADED, APPLY SOIL AMENDMENTS AND INITIAL FERTILIZERS AS 5FEC,IFIED IN ALL LAY'IN AND GROUND C,OVER AREAS Yilll! A SLOPE OF :;,1 OR FLATTER. ALL LAYiN AREAS SHALL BE CROSS-RIFFED IN TYiO DIREC,TIONS TO A DEPlll OF e INCHES MINIMUM BELOYi FINISH 5RADE. DURINS THIS OPERATION, ALL STONES OVER I INC,H IN GREATEST DIMENSION SHALL BE REMOVED. REMOVE HliSH AREAS AND FILL IN DEPRESSIONS. TILL TO A DEFlll OF NOT LESS ll!AN b INCHES EY ROTOTILLINIS A MINIMUM OF TriO (2) ALTERNATIN& PASSES. TILL SOIL TO A HOMOGENEOUS MIXTURE OF FINE TEX11JRE, FREE OF LUMPS, GLODS, STONES, ROOTS AND OTHER EXTRANEOUS MATTER. GRADE SHALL BE RETIJRNED TO l1IE CONDITION OF THE APPROVED GRADING PLANS. 3.:l.1.1. PRIOR TO PREPARATION OF UNSRADED AREAS QESl&NED TO BE LANDSCAPED, REMOVE EXISTINS VEGETATION AND YiEED5. PROPERLY Dl5FOSE OF SUC,H MATERIAL OUTSIDE OF OY'INER'S PROPERTY. 3.3.1.1.1. SOIL AMENDMENTS SHALL BE APPLIED AT ll!E RATES RECOMMENDED BY THE SOIL TE5TIN5 LAB. THE FOLLOYilNG ¼HEDULE 15 FOR EIDDINS PURPOSES ONLY. ADJJ5TMENT5 MAY BE NECESSARY. 3.3.1.1.1.1. ORGANIC, AMENDMENT b cu. YD. PER rpoo SQ. FT. 3.:l.1.1.1.2. IRON SULFATE, 20 LES PER IPQO SQ. FT. 3.3.1.1.1.3. GYPSUM, 120 LES FER IPQO SQ. FT. 3.:l.1.1.1.4. PRE-PLANT FERTILIZER, 30 LES PER IPOO SQ. FT. 3.:l.2 ALL SLOPE AREAS 2,1 OR STEEPER SHALL RECEIVE 5YPSUM AT A RATE OF 120 LES. FER rpoo 50. FT. 3.4. EXCAVATION FOR TREES AND 5HRIJES 3.4.1. WNTAINER 5ROY'IN STOCK IN C,ANS SHALL EE REMOVED YilTHOUT DISTURBIN5 THE ROOT BALL. STOC,K GROY'IN IN BOXES SHALL HAYE BOTTOMS REMOVED. ALL USED CONTAINERS SHALL BE REMOVED TO THE STORAISE AREAS OR FROM l1IE SITE. EAe,H TREE AND SHRIJE SHALL BE PLACED IN THE C,ENTER OF THE HOLE AND SHALL BE SET PLUMB, REMOVE SIDES OF BOXES AND HOLD RIGIDLY IN POSITION UNTIL THE PLANTINIS BAC,KFILL HAS BEEN TAMPED AROUND EAC,H ROOT EALL. 3.4.1.1. FOR CONTAINER 5ROY'IN STOCK, EXC,AVATE AS SPECIFIED FOR SIZE Of C,ONTAINER t'ilDTH AND DEFlll. 3.4.1.2. DISPOSE OF EXCESS SUBSOIL REMOVED FROM PLANTING EXCAVATIONS. 3.4.1.:l. FILL EXCAVATIONS FOR TREES AND SHRl!BS t'ilTH YiATER AND ALLOYi YiATER TO PERCOLATE OUT PRIOR TO PLANTING. 35. PLANTINIS TREES AND SHRUBS 35.1. ALL PLANTS SHALL BE SET AT SUCH A LEVEL ll!AT AFTER SETTLING, ll!EY BEAR ONE INC,H ABOVE THE SURROUNDING FINISH GRADE AS 11!EY BORE TO THE SOIL LINE iSRADE IN l1IE C,QNTAINER. 35.2. PLANTINIS TABLETS SHALL BE PLAC,ED IN EACH TREE AND 5HRiJE PLANTINS HOLE AT l1IE FOLLOYilNIS RA TE, B5.2.I. 1-21 iSRAM TABLET PER I GALLON CONTAINER. 95.22. 3-21 GRAM TABLETS FER 5 GALLON GOI-IT'AINER. 9.5.2.:l. 4-21 GRAM TABLETS PER 15 <SALLON CONTAINER. 35.2.4. 1-21 GRAM TABLET FER EACH 4 INCH OF BOX SIZE. 3.5.25. 1-5 GRAM TABLET FER FLATTED OR LINER PLANT. 3.5.3. NO PLANT t'ilLL BE ACC,EPTED IF THE ROOTBALL 15 BROKEN OR C,RACKED, Elll!ER BEFORE, Dl/RINIS OR AFTER THE PROCESS OF INSTALLATION. 35.4. YiATER BASIN SHALL BE FORMED Al<OIJND EAC,H TREE AND 5HRiJE PER DETAIL. ALL PLANTS SHALL BE THOROUGHLY YiATERED IMMEDIATELY AFTER PLANTINIS. 35.5. MN DIREC,TED 6Y THE LAND¼AFE ARCHITEC,T, C,ONTRACTOR SHALL PRUNE, THIN OUT, AND SHAFE TREES AND SHRUBS IN AC,C,ORDANCE Yillll STANDARD HORTIC,UL 11JRAL FRACTIC,E. PRUNE TREES TO RETAIN REGIUIRED HEIISHT AND SPREAD. UNLESS OlllERYilSE DIRECTED EY LAND¼AFE ARCHITEC,T, DO NOT C,UT TREE LEADERS, AND REMOVE ONLY !NJ.IRED OR DEAD BRANCHES FROM FLOY'IERINS TREES, IF ANY. PRUNE TREES AND 5HRiJE5 TO RETAIN NATIJRAL C,HARAC,TER, 3.5.b. REMOVE AND REPLACE EXCESSIVELY PRUNED OR MISFORMED STOCK RESULTING FROM IMPROPER PRIJNIN5. 35.1. STAKE TREES IMMEDIATELY AFTER PLANTING, AS INDIC,ATED. ALL TREES, 15 GALLON AND SMALLER SHALL BE 51N5LE STAKED, 24' BOX AND LARGER SHALL BE DOUBLE STAKED AS INDIC,ATED ON DRAY'INISS. l1IE STAKES SHALL BE DRIVEN IN PLUMB AND 5EGURE. SPECIAL C,ARE SHALL BE TAKEN THAT THE DRIVINIS IN OF THE STAKE DOES NOT DAMAISE THE TREE ROOTS OR ROOTBALL. TREE TIES SHALL BE FASTENED PER DETAIL. 3h. HYDROSEEDING 3.b.l. INSPECTION OF C,ONDITIONS, BEFORE PROC,EEDINS Yillll ANY YiORK, THE HYDR05EEDIN5 LAND¼APE CONTRACTOR SHALL C,AREFULLY C,HEc;K PLANTINIS AREA C,ONDITIONS AND SHALL IMMEDIATELY INFORM l1IE LAND¼APE ARCHITEC,T OF ANY DISCREPANC,IES SEMEN THE Di<mlNGS AND AC,11JAL CONDITIONS. NO YiORK SHALL BE DONE ON ANY AREA MRE THERE ARE SUC,H Dl¼REFANCIES OR YiHERE C,ONDITIONS ARE UNSUITABLE FOR SUC,C,E55FUL PLANT MATERIAL ESTABLISHMENT UNTIL APPROVAL HAS BEEN GIVEN BY ll!E LAND¼AFE ARCHITEC,T. 3.o.2. GUALITY OF Y'IORK, l1IE HYDROSEEDINIS YiORK SHALL BE PERFORMED BY A COMFETENTL Y TRAINED INDIVIDUAL OR HYDROSEEDINIS COMPANY IN ACGORDANCE Yillll THE BEST STANDARDS AND FRACTIC,ES RELATED TO l1IE TRADE. 3h13. SOIL FREFARATION, YiATER ALL FLANTINIS AREAS THOROUISHLY AND CONTINUOUSLY FOR THREE (3) CON5EC,UTIYE DAYS TO SATIJRATE UPPER LAYERS OF SOIL PRIOR TO HYDROSEEDINi, OPERATION. ALLOVi PLANTINS AREA SOIL SURFACE TO DRY OUT FOR ONE DAY ONLY PRIOR TO THE HYDROSEEDINIS AFPLIC,ATION. e,ARE MUST BE TAKEN TO NOT ALLOYi THE SOIL SURFACE TO BE SUPER 5A11JRATED Yillll YiATER PRIOR TO ll!E HYDROSEEDINi, INSTALLATION AT ll!E SAME TIME l1IE SOIL SURFACE SHOULD NOT BE BONE DRY. THERE SHOULD BE SOME RESIDUAL MOl511JRE YilTHIN THE FIRST 1/4 INCH OF SOIL SURFAC,E. 3h.4. BEiSIN THE HYDROSEEDINS OPERATION ON ALL AREAS AS 5FECIFIED HEREIN. 3h.4.I. HYDROM\JLC,HINIS APPLIC,ATION AND PLANTING SCHEDULE, THE HYDROMULCHING SHALL EE APPLIED IN THE FORM OF A FLURRY C,QNSISTING OF ORISANIC, SOIL AMENDMENT5, C,OMMERCIAL FERTILIZER, AND OTHER C,HEMIC,AL5 C,ALLED FOR. YiHEN HYDRAULIC,ALLY SPRAYED ONTO THE SOIL, THE MULCH SHALL NOT FORM A BLOTTER LIKE MATERIAL. l1IE SPRAY OPERATION 11J5T BE 50 DIREC,TED ll!AT 111E SLURRY 5FRAY YilLL ALSO PENETRATE THE SOIL SURFAC,E AS TO DRILL AND MIX THE SLURRY COMPONENTS INTO l1IE SOIL, THUS EN5URIN5 MAXIMUM IMPREiSNATION AND C,OYERAISE. 3h.42. PREPARATION OF HYDROSEEDING MIXTIJRE, l1IE SLURRY SHALL BE PREPARED AT THE SITE AND ITS C,OMPONENT5 SHALL BE MIXED TO SUPPLY l1IE RATES OF APPLIC,ATION AS PER 5PEC,IFIC,ATIONS. 3.o.43. SLURRY FREFARATION SHALL BE5IN 6Y ADDINS YiATER TO ll!E LINK YiHEN THE ENiSINE 15 AT ONE-HALF THROmE. MN THE YiATER LEVEL HAS REACHED l1IE HEIGHT OF THE AISITATOR SHAFT AND GOOD REC,IRC,ULATION HAS BEEN ESTABLISHED, THE FERTILIZERS SHALL BE ADDED TO THE MIXTIJRE (THE TANK SHALL BE AT LEAST 1/3 FILLED YilTH YiATER AT THIS TIME). 3.o.4.4. THE EN51NE ll!ROTTLE SHALL EE OPEN TO FULL SPEED MN THE TANK 15 1/2 FILLED f"IITH YiA TER. ALL ORISANIC, AMENDMENTS, FIBER, AND e,HEM[C,ALS SHALL ll!EN BE ADDED EY l1IE TIME THE TANK 15 2-1/3 TO 3/4 FULL. AT THIS TIME THE SEED MIX SHALL ALSO BE ADDED. 9.o.4.5. 5PRAYIN5 SHALL C,OMMENC,E IMMEDIATELY YiHEN THE TANK 15 FULL AND THE SLURRY 15 MIXED. 3h.5. APPLICATION, ll!E OPERATOR SHALL SPRAY ll!E AREA Yillll A UNIFORM VISIBLE C,QAT U51N5 THE DARK COLOR OF THE C,ELLULOSE FIBER OR ORISANIC. AMENDMENT AS A VISUAL GUIDE. l1IE SLURRY SHALL BE APPLIED IN A DOY'INY'IARD DRILLING MOTION VIA A FAN STREAM NOZZLE. 9hh. TIME LIMIT, THE HYDROl1JLC,HIN5 SLURRY C,OMPONENTS ARE NOT TO BE LEFT IN l1IE HYDROMJLGH MACHINE FOR MORE THAN TYiO HOURS. IF SLURRY C.OMPONENTS ARE LEFT FOR MORE ll!AN TriO HOURS IN 111E MACHINE, l1IE C,ONTRACTOR SHALL ADD 50 % MORE OF ll!E ORIGINALLY SPEC,IFIED SEED MIX TO ANY SLURRY MIX YiHIC,H HAS NOT BEEN APPLIED Yilll!IN THE TriO HOURS AFTER MIXING. ll!E C,ONTRACTOR SHALL ADD 15% MORE OF THE ORIGINAL SEED MIX TO ANY SLURRY MIXTURE Y'IHIC,H HAS NOT BEEN APPLIED EIISHT HOURS AFTER MIXINS. ANY MIXTURE NOT APPLIED AFTER EIGHT HOURS SHALL BE REJEC,TED AND DISPOSED OF OFF-SITE AT CONTRACTORS EXPENSE. 3.b.1. PROTECTION, SFEc;IAL C,ARE 15 TO EE EXERCISED BY THE C,QNTRAC,TOR TO PREVENT ANY OF THE SLURRY FROM BEINIS SPRAYED ONTO ANY ADJACENT PROPERTY, ETC,_ ANY SLURRY SPRAYED ONTO THESE AREAS SHALL BE C,LEANED OFF AT l1IE e,oNTRACTOR'S EXPENSE. 3.b.e. HYDROM\JLC,HINS ¼HEDULE, AS AN ADDED FRECAUTION, l1IE HYDROSEEDED AREA SHALL BE PRESOAKED YilTH YiA TER EY l1IE IRRIGATION SYSTEM TO A DEPTH OF THREE (3) INCHES 48 HOURS PRIOR TO THE HYDROSEEDINS INSTALLATION. 3.i;_q_ AFFLIC.ATION RATES, C,ELLULOSE FIBER -2POO LBS/ACRE M-BINDER -140 LBS PER ACRE SEED MIX -AS INDIC,A TED ON DRmlN55 FERTILIZER. 11JRF AREA -(12-12-12) -400 LES. / ACRE OTHER AREAS -(0-3b-O) -300 LES./ ACRE (38-0-0) -50 LBS. I AC,RE 9.b.10. HYDROSEEDING EGUIPMENT, l1IE SPECIFIED COMPONENTS SHALL EE MIXED TOISEll!ER IN A HYDROSEEDINS MACHINE DESC,RIBED AS FOLLOYiS, 3.b.lO.I. THE HYDROMULCHINS EGUIPMENT SHALL MEET THE MINIMUM REGIUIREMENTS OF A SLURRY DISTRIBUTION LINE LARISE ENOt.<;H TO PREVENT C,LOSINIS AND C,ONTINUOUS NON FLUC11JATIN5 DISCHARISE OF AT LEAST 25 PSI AT THE END OF l1IE SPRAY NOZZLE. THE SLURRY TANK SHALL HAYE A MINIMUM C,APACITY OF 2000 5ALLON5 AND SHALL BE MOUNTED ON A TRAYELINS UNIT EITHER SELF-PROPELLED OR DRAY'IN BY A SEPARATE UNIT. •• . rrr. I II • • 3.b.I02. l1IE EQUIPMENT SHALL HAYE A EUILT-IN AISITATION SYSTEM UNDER OPERATING CAPACITY SUFFIC,IENT TO AISITATE, 5U5PEND AND HOMOISENEOUSLY MIX A SLURRY CONTAINING NOT LESS THAN 20 KILOS (44 LBSJ OF ORGANIC, MULC,HINIS AMENDMENT PLUS FERTILIZER CHEMlc;AL ADDITIVES AND SOLIDS FOR EAC,H 100 iSALLONS OF YiA TER. • 9.1. FLANTINS 5ROUND COYER 3.1.1. 5FACE GROUND C,OVER PLANTS AS INDIC,ATED OR SC,HEDULED. 3.12. DIG HOLES LARISE ENOUGH TO ALLOYi FOR 5PREADIN5 OF ROOTS AND BACKFILL YilTH PLANTINIS SOIL. YiORK SOIL ARoUND ROOTS TO ELIMINATE AIR FOC,KETS AND LEAVE A SLIISHT SAUC,ER INDENTATION AROUND PLANTS. YiATER THORO\JGHLY AFTER PLANTINS, TAKINS e,ARE NOT TO C,OVER C,ROY'INS OF PLANTS Yillll ViET SOILS. PROVIDE PLANT TABS PER SPEC,IFIC,ATION 3.52. 3.1.3. PROVIDE 3 INCH THIC,KNESS OF BARK M\JLC,H IN ALL NON-11JRF PLANTINIS AREAS LESS STEEP THAN 3,1 (RIPARIAN AREAS EXCLUDED) 3b. POST FERTILIZATION B.8.1. POST FERTILIZATION FOR ALL AREAS SHALL OCCUR AFTER PLANTIN5 AT A RATE 5PEC,IFIED IN l1IE SOIL TEST RECOMMENDATIONS. 3.q. MAINTENANCE PERIOD 3_q_1, THE MAINTENANCE PERIOD BEGINS ON ll!E FIRST DAY AFTER ALL LANDSCAPE, IRRIGATION, AND ALL OTHER INDIC,ATED OR SPEC,IFIED YiORK ON THIS PROJEC,T 15 COMPLETE, e,HECKED, ACC,EPTED AND YiRITTEN APPROVAL FROM THE LAND¼AFE ARCHITECT 15 GIVEN. 3_q2. THE C,ONTRAC,TOR SHALL C,ONTINUOUSLY MAINTAIN ALL INVOLVED AREAS OF THE C,ONTRACT DURIN5 THE PROGRESS OF THE Y'IORK AND DURIN& THE MAINTENANc;E PERIOD UNTIL THE FINAL ACCEPTANCE OF THE YiORK. 3.q.:J, l1IE MAINTENANCE PERIOD SHALL CONTINUE UNTIL FINAL ACCEPTANCE, BUT IN NO e,ASE, LESS THAN qo DAYS AFTER AFFROYED C,OMPLETION OF LAND¼APIN5. 3,q,4, l1IE C,ONTRACT COMPLETION DATE OF THE CONTRACT MAINTENANCE PERIOD YilLL BE EXTENDED, MN IN THE OPINION OF THE LANDSC,APE ARC,HITEC,T, IMPROPER MAINTENANCE AND/OR POSSIBLE POOR OR UNHEALTHY CONDITION OF PLANTED MA TERI AL OR UNESTABLISHED NON-GOVERINIS LAY'INS ARE EVIDENT AT l1IE TERMINATION OF THE 5C,HEDl/LED MAINTENANCE PERIOD. THE C,ONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL MAINTENANCE OF THE YiORK AT NO C,HANISE IN CONTRACT PRIC,E UNTIL ALL OF THE Y'IORK 15 COMPLETED AND AC,C,EPTED LAND5C,AFE ARCHITEC,T. 3_q5_ l1IE C,ONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ADEGUATE PROTEC,TION OF ll!E LAND¼AFE AREAS. DAMAISED AREAS SHALL BE REFAIRED IMMEDIATELY AT l1IE C,ONTRACTOR'S EXPENSE. 9,qh. THE CONTRACTOR MAINTAIN TREES, SHRUES, AND OTHER PLANTS BY FRUNINIS, MOVilN5, CULTIVATINS, AND YiEEDINS AS REQUIRED FOR HEALTHY iSROYilll; C,ONTRAC,TOR SHALL RESTORE PLANT YiATERIN5 BASINS, Tl5HTEN AND REPAIR STAKE AND 5UY SUPPORTS, RESET TREES AND SHRl!BS TO PROPER iSRADES OR VERTIC,AL POSITION AS REQUIRED, AND 5PRA Y AS REQUIRED TO KEEP TREES AND SHRIJES FREE OF INSEC,TS AND DISEASE. 3.10. C,LEANUF AND PROTEC,TION 3.10.1. DURINS LAND¼AFE Y'IORK, KEEP PAVEMENTS GLEAN AND Y'IORK AREA IN AN ORDERLY C,ONDITION. 3.10.2. PROTEC,T LANDSCAPE YiORK AND MATERIALS FROM DAMAISE DUE TO LAND¼APE OPERATIONS, OPERATIONS EY OTHER C,ONTRACTORS AND TRADES, AND TRESPASSERS. MAINTAIN PROTECTION DURINS INSTALLATION AND MAINTENANC,E PERIODS. TREAT, REFAI~ OR REFLACE DAMAiSED LANDSCAPE YiORK AS DIREC,TED. 3.11. SITE OBSERVATION Vl51T5, 3.12.1. SITE OBSERVATION Vl51T5 HEREIN 5PEC,IFIED SHALL BE MADE BY THE C,ITY INSFEC,TOR AND THE LANDSCAPE ARCHITEC,T. l1IE C,ONTRAC,TOR SHALL REGIUE5T SITE OESERVATION IN 48 HOURS ADVANCE OF THE TIME OBSERVATION 15 REGUIRED. 3.112. SITE OBSERVATION t'ilLL BE REGIUIRED FOR ll!E FOLLOYilNS PART5 OF THE Y'IORK, 3.11.2.1. INCORPORATION OF SOIL CONDITIONER AND FERTILIZER INTO THE SOIL. 3.11.22. UPON COMPLETION OF FINISH GRADING PRIOR TO PLANTINS. 3.11.2.3. APPROVAL OF PLANT MATERIALS. 9.112.4. YiHEN PLANTIN5, AND ALL OTHER INDIC,ATED OR SFEC,IFIED YiORK, EXCEPT l1IE MAINTENANCE PERIOD, HAS BEEN COMPLETED. 3.11.2.5. FINAL SITE OBSERVATION VISIT AT THE COMPLETION OF THE MAINTENANCE PERIOD. THIS SITE OESERVATION VISIT SHALL ESTABLISH l1IE BEGINNINIS DATE FOR l1IE YiARRANTY PERIOD Of PLANT MATERIAL. 9.112.b. UPON COMPLETION OF THE YiARRANTY PERIOD. 3.11.3. ACCEPTANCE, UPON C,OMPLETION OF THE FINAL SITE OBSERVATION VISIT AND 111E YiORK OF THIS SEC,TION, THE C,ONTRAC,TOR YilLL BE NOTIFIED IN YiRITINIS (I) YiHETHER THE YiORK 15 AC,C,EPTABLE; (2) OF ANY REQUIREMENTS NECESSARY FOR COMPLETION AND ACCEPTANCE. 3.11.4. THE CONTRAC,TOR OR HIS AUTHORIZED REFRESENTATIYE SHALL BE ON ll!E SITE AT l1IE TIME OF EACH SITE OBSERVATION VISIT BY THE LANDSCAPE ARCHITECT. S.11.4. THE CONTRACTOR SHALL CONTACT THE LANDSC,APE ARC,t-!ITECT PRIOR TO BE61NNIN6' LANDSCAPE Y'k)RK 50 THAT Tl-IE LANDSC.APE ARGHITECT C.AN REVIEYII THE FROJl::C.T UTILITY LOCATIONS AND REVISE: PLANS ACCORDINGLY. EN, (If SEGTIOII 02'IOO "AS-BUILT " Call: TOLL FREE • 1-800 -- 422-4133 EXP. DATE REVIEWED BY: TV'IO i"IORKINcS DAYS BEFORE YOU DlcS INSPECTOR DATE LAND PLANNING LANDSCAPE ARCHITECTURE 2979 STATE STREET SUITE "C" C A R L S B A D, C A, 9 2 0 0 B (760) 729-e 6 J7 FAX:(760)72 9 -~32 ~ -[_T71CfTY OF CARLSBA°7 !5H1~EEfEfs7 ------+--~~---+-----,-----, C PLANNING DIVISION LlJ ---------------+----+---+------, ----l ··:":::=====·· :-__ -_-_-_ --~--=----_.-::_ I PLANTING SPECIFICATIONS 92008 +---+-----+----+----- 1.o.2. EXCAVATION, MN CONDITIONS DETRIMENTAL TO PLANT 5ROYilll ARE ENCOUNTERED, SUC,H AS RUBBLE FILL, ADVERSE DRAINAGE C,ONDITIONS, OR OESTRUC,TIONS, NOTIFY LAND¼AFE ARCHITECT BEFORE PLANTINS. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATIONS OF PLANTING AREAS DATE, "1-12-16 JOB NO., 21511 SCALE: DRAWN BY: ; I PLANNING DATE DATE , INITIAL ENGINEER OF WORK REVISION DESCRIPTION DA ___ T_E I ____ INITII\L DATE INITIAL f"D:WN BY: --PROJECT NO. DRAWING NO. I ~~KD BY: HMP 16-01 490-IL OTHER APPROVAL CITY APPROVAL I RVWD BY:-~ --~~ I