Loading...
HomeMy WebLinkAboutCUP 2020-0012; T-MOBILE ANCHOR - FARADAY EXECUTIVE CENTER; Administrative Determinationc:i UJ f-ro :r: 0 0:: 0. >-~ t, i5' to '!! CJ) UJ 0 ~ UJ CJ) 0:: UJ i5' 0:: <( u 0 f--- U) UJ f-::i UJ 0:: :r: u ;ii ~ I f-z <{ :r: f- 0:: UJ r 5 UJ 0:: ::, 8 ~ u U) 0 0:: 0 UJ en ::, >-z <{ UJ 0:: ::, ~ z in >-0:: ~ i5' Cl. 0 0:: 0. U) U) f-z UJ "' :::, 8 0 z 0 6 ::, 0:: l;, z 0 <.) u. 0 f-UJ en '!! :r: f-z 0 UJ z i 0 z 0 ~ "' SPEC IAL IN SPECTIONS -2019 CBC CHAP. 17 ITEM MATERIAL REQUIRED 2019 CBC STANDARDS REFERENCE HILTI KWIK ICC ESR-1917 CABINET BOLTTZ PERIODIC 1705.3 ITEM 4 SECTION 4.4 9/A-5.1 ANCHOR STAINLESS BASIS ACI 318: 17 82.4, STEEL 17.8.2 PROJECT INFORMATION SITE NAME: SITE NUMBER: SITE ADDRESS: JURISDICTION: COUNTY OF: LATITUDE: LONGITUDE: CONSTRUCTION TYPE: AP.N.: ZON ING CLASSIFICATION: PROPOSED USE: LEGAL DESCRIPTION : PROPERTY OWNER: FARADAY EXECUTIVE CTR SD069 18A 2382 FARADAY AVENUE CARLSBAD, CA 92008 CITY OF CARLSBAD COUNTY OF SAN DIEGO 33.1366401600°N 117 .27 48890000°w TYPE V 1-HR, SPRINKLED 212-062-17 & 212-062-18 M-7 INDU STRIAL UNMANNED TELECOMMUN ICATION FACILITY REFER TO SHEET 2/T-3.0 l&G FARADAY INC. 5800 ARAMADA DRIVE, STE. 101 CARLSBAD, CA 92008 PHONE: 760-517-5819 T-MOBILE PROJECT MANAGER: JOSEPH ROSE (858) 334-6112 APPLICANT: joseph. rose41@T-Mobile.com T-MOBILE JOSEPH ROSE (858)334-6112 joseph.rose4 1@T-Mobile.com PROJECT TEAM ARCHITECT: SAC AE DESIGN GROUP, INC. NESTOR POPOWYCH, A.I.A 50 15 SHOREHAM PLACE, STE 150 SAN DIEGO, CA92122 CONTACT: DENNIS YOSHII PHONE (619) 736-3766 X105 EMAI L: dennis .yoshii@sacw.com ENGINEER: LETS IN C. MADHAN KUMARK MS, P E 11 2 SOUTH KYRENE ROAD, STE 1 CHANDLER, AZ 85226 PHONE: (480) 406-5087 EMAIL: madhank@letsinc.com PLANNING/ZONING CONSULTANT: SAC AE DESIGN GROUP, INC. CAROL KINCHELOE 5015 SHOREHAM PLACE, STE 150 SAN DIEGO, CA 92122 PHONE (619) 488-0933 EMAIL: carol.kincheloe@sacw.com CONSTRUCTION MANAGER: T-MOBILE USA KIRT BABCOCK 10509 VISTA SORRENTO PKWY STE 206 SAN DIEGO, CA 9212 1 PHONE: (858) 334-6139 EMAIL: kirt.babcock@T-Mobile.com RF ENGINEER: T-MOBILE USA MUSTAFAAJMAL 10509 VISTA SORRENTO PKWY STE 206 SAN DIEGO, CA 92121 PHONE: - EMAIL: mustafa.ajmal@T-Mobile.com w NORTH ~ NORTH c111i•v·rii"~ 11~rcnn:1ry Sp<!Clallli!S SITE NUMBER: SITE NAME: ADDRESS: JURISDICTION : PROJECT: • SD06918A FARADAY EXECUT IV E CTR 2382 FARADAY AVENUE CARLSBAD, CA 92008 CITY OF CARLSBAD L700-L 1900-ANCHOR LOCATION MAP SCOPE OF WORK 9 El Cam,n□ Ren11Jl B Spectrum 9 13 US Hea1·~Wi:ITT-s Ur~nl Cllrc Cor:SOOd Alph;;lee :;plr,e 9 VI CINITY MAP SITE SITsE McClell:in·Pa1om.,r Airport • .. ' . ..,_ TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN CALIFORNIA (SOUTH), CALL DIG ALERT TOLL FREE: 1-800-227-2600 OR www.digalert.org 1 j T-MOBILE PROPOSES TO: • REMOVE (6) EXISTING PANEL ANTENNAS • INSTALL (6) NEW 6X12 HCS 4AWG CABLE • REMOVE (6) EXISTING DUMMY PANEL • INSTALL (1) PBC 6200 BATTERY CABINET ANTENNAS • INSTALL (2) 6630 IN SIDE EQUIPMENT • INSTALL (3) NEW APXVAARR18 PANEL CABINET ANTENNA • INSTALL (1) NEW PSU 4816 • INSTALL (3) NEW AIR6449 PANEL ANTENNA • INSTALL (1) NEW POWER 6230 • INSTALL (3) NEW AIR32 PANEL ANTENNA • INSTALL (1) 6648 INSIDE EQU IPMENT • INSTALL (9) NEW PIPE TO PIPE CLAMPS CABINET • INSTALL (9) ANTENNA SKIRTS • NO NEW BATTERIES TO BE ADDED • INSTALL (3) NEW RADIOS (4449 B85+B71) • REMOVE (1) PBC 6500 BATTERY CAB INET • INSTALL (3) NEW RADIOS (4415_825) • PROJECT VALUATION $50 ,000 DRIVING DIRECTIONS DIRECTIONS FROM 10509 VISTA SORRENTO PKWY, SAN DIEGO CA 92121 1. CONTINUE STRAIGHT TO STAY ON ONTO COLLEGE BLVD SCRANTON RD 9. TURN RIGHT ONTO FARADAY AVE 2. TURN LEFT ONTO MIRA SORRENTO PL 10 . DESTINATION WILL BE ON THE LEFT 3. USE THE RIGHT 2 LANES TO TAKE THE RAMP ONTO 1-80 5 N 4. MERGE ONTO 1-805 N 5. MERGE ONTO 1-5 N 6. TAKE EXIT 47 FOR PALOMAR AIRPORT RD 7. USE THE RIGHT 2 LANES TO TURN RIGHT ONTO PALOMAR AIRPORT RD 8. USE THE LEFT 2 LANES TO TURN LEFT GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE REQUIRED AND NO CO MMERCIAL SIGNAGE IS PROPOSED. DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & FIELD CONDITION S ON THE JOB SITE & SHALL I MME DIA TEL Y NOTIFY THE ARCHITECT OR ENGINEER OF RECORD IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. SPECIAL NOTES 1. ALL WORK SHALL BE IN STALLED IN CONFORMANCE WITH CURRENT T-MOBILE CONSTRUCTION IN STALLATION GUIDE . 2. EXIST ING CONDITIONS WILL BE VERIFIED IN FIELD. IF SIGN IFICANT DEVIATIONS OR DETERIORATION ARE ENCOUNTER ED AT 4· THE TIME OF CONSTRUCTION , A REPAIR PERMIT WILL BE OBTAINED & CONTRACTOR SHALL NOTIFY ARCH ITECT 5· OR ENG INEER OF RECORD IMMEDIATELY RECORD IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONS IBLE FOR THE SAME. THESE DRAWINGS ARE FULL SIZE & SCALEABLE ON 22"X34" SHEET SIZE & ARE NOT REDUCED IN SIZE. 6 Know what's be low. u. CALIFORNIA STATUTE REQUIRES MIN OF 2 WORKING DAYS NOTICE BEFORE YOU EXCAVATE 3. CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY STATEMENT THAT COMPLIANCE WITH THE ENERGY CODE IS NOT REQUIRED. -SCOPE OF WORK DOES NOT INVOLVE MODIFICATION S TO EXTERIOR ENVELOPE OF BUILDING, HVAC SYSTEMS OR ELECTRICAL LIGHTING. DRAWING IND EX SHEET DESCRIPTION T-1.0 TITLE SHEET T-2.0 GENERAL NOTES T-3.0 ABBREVIATIONS, LEGAL DESCRIPTION, REFERENCED DOCUMENTS, LEGEND & SIGNAGE A-1.0 OVERALL SITE PLAN A-2.0 ENLARGED ROOF PLAN ' A-3.0 EX ISTING & PROPOSED ANTENNA PLANS & SCHEDULES A-3.1 ANTENNA MOUNTING DETAIL A-3.2 RADIO MOUNTING DETAILS A-3.3 EXISTING & PROPOSED EQUIPMENT PLANS , & EXISTING BATTERY CALCULATIONS A-4.0 EX IST ING & PROPOSED NORTH ELEVATIONS A-4 .1 EXISTING & PROPOSED EAST ELEVATIONS A-4.2 EXISTING & PROPOSED SOUTH ELEVATIONS A-4.3 EXISTING & PROPOSED WEST ELEVATIONS A-5.0 EQU IPMENT DETAILS & SPECIFICATIONS A-5.1 EQUIPMENT DETAILS & SPECIFICATIONS A-5.1 EQ UIPMENT DETAILS & SPECIFICATIONS S-1 .0 STRUC TURAL DETAILS G-1.0 SC HEMATIC GROUNDING PLANS , NOTES & DETAILS RF-1.0 EQUIPMENT CONFIGURATION NOT FOR CONSTRUCTION UNLESS APPROVED BY JURISDICTION CODE COMPLIAN CE • 2019 CALIFORNIA ENERGY CODE • 20 19 CALIFORN IA BU ILDING CODE • 2019 CALIFORNIA ELECTRICAL CODE • 2019 CALIFORN IA FIRE CODE • 2019 CALIFORNIA MECHANICAL CODE • 2019 CALIFORNIA PLUMBING CODE APPROVALS THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HERE IN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOS E CHANGES OR MODIFICATIONS. T-MOBILE PROJECT MANAG ER: DATE T-MOBILE CONSTRUCTION MANAGER: DATE: T-MOB ILE RF ENGINEER: DATE: T-MOBILE FOPS: DATE: SITE ACQUISITION: DATE: PROPERTY OWNER: DATE: REV. C!TY OF CARLSBAD Administrativf' Permit ~··Mobile· 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM !ii~ WI RE L ESS SAC AE DESIGN GROUP, INC. 5015 SHOREHAM PLACE, SUI TE 150 SAN DIEGO, CA 92122 www.sacv,,.com REVISIONS DATE OESCMIPTION 111.'ITIALS 0 07108/2020 90% CD's EC 1 07/14/2020 100% CD's EC • • • ESTO T. POPOWYC -27496 REN WAL 4-30-19 ·* "I HER • • • PREPARED B R MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE TITLE SHEET SHEET NUMBER T-1.0 ~ Ca ll before you dig. i!:L,:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;~;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;:!_.:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;!..!;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;:..J , ________ .., REV1 .O_ Q:1$TELE\$T-MOBILE PROJECTSISAN DIEGO SITESISD069 18A -FARADAY EXECUTIVE CENTER\2 -L700-L 1900-CABLE RE LO-ANCHOR PROJECT\L700-L 1900-CABLE RELO-ANCHOR_CD'S\TMO-SD06918A-L700-L 1900-CABLE RELO-ANCHOR_CD"S.DWG -2017-09-15 -ECampos NOTIFY THE ARCHITECT OR ENGINEER OF ZON ING DATE: RECEIVED DEC O 9 2020 Cl fY OF CARLSBAD PLANNING DIVISION -' 0 w f-a, 5: 0 "' a. ~ 0 °' f-- U) U) U) w u ~ w U) "' w °' ~ ;::, U) w " ~ w "' :i: u I i f-z 'f f- "' w :i: ti w "' ::, U) 0 ~ u (/) 0 °' 0 w U) ::, >-z < ui °' ::, ~ 6:i i;:; ~ °' a. 0 8: U) U) !,e w "' ::, 8 □ 15 B ::, "' t;; z 8 u. 0 f-w U) (/) 5: f-z 0 w z ~ 15 u z 0 ~ "' °' 0 u. z w I f- GENERAL NOTES: 1. THIS FACILITY IS EXEMPT FROM ACCESSIBILITY REQUIREMENTS PER CALIFORNIA/INTERNATIONAL BUILDING CODE SECTION 11 B-203.5. THIS FACILITY IS NON-OCCUPIABLE SPACE AND ENTERED ONLY BY SERVICE PERSONNEL. 2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING CODE, THE LATEST EDITION AND ALL OTHER APPLICABLE CODES AND ORDINANCES. 3. CONTRACTOR SHALL CONSTRUCT SITE IN ACCORDANCE WITH THESE DRAWINGS AND CONSTRUCTION SPECIFICATIONS. THE SPECIFICATION IS THE RULING DOCUMENT AND ANY DISCREPANCIES BETWEEN THE SPECIFICATION AND THESE DRAWINGS SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER OF RECORD PRIOR TO PROCEEDING WITH CONSTRUCTION. 4. CONTRACTOR SHALL VISIT THE JOB SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PREVISIONS AS TO THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND CONFORMING THAT THE WORK MAY BE ACCOMPLISH AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF WORK. NO COMPENSATION WILL BE AWARDED BASED ON CLAIM OF LACK OF KNOWLEDGE OF FIELD CONDITIONS. 5. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT AND APPURTENANCES, AND LABOR NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. OWNER PROVIDED MATERIALS WILL INCLUDE THE FOLLOWING, UNLESS NOTED OTHERWISE: A. TRANSMITTER B. RF FILTER C. MFTS RACKS D. AUXILIARY EQUIPMENT IN MFTS RACK E. PUMP ASSEMBLY F. HEAT EXCHANGE G. HOSE AND HOSE MANIFOLD {ANY COPPER OR STEEL SECTION PROVIDED BY CONTRACTOR) H. UHF ANTENNA AND MOUNTING BRACKET, GPS ANTENNA AND KU ANTENNAS I. UHF COAX AND HANGERS J. 480-208 & 208-400 ELECTRICAL TRANSFORMER K. AUTOMATIC TRANSFER SWITCH AND GENERATOR L. EQUIPMENT SHELTER (SHELTER FURNISH IN FACTORY W/HVAC EQUIPMENT AND ELECTRICAL DISTRIBUTION PANEL) M. INTEGRATED LOAD CENTER N. ANTENNAS, RADIOS & CABLES 6. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE WORK. 7. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 8. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENT. 9. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. - 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS. 11. CONTRACTOR SHALL COORDINATE HIS WORK WITH THE SUPERINTENDENT OF THE BUILDING & GROUNDS & SCHEDULE HIS ACTIVITIES AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS AND ANY OTHER PORTIONS OF THE WORK. 13. INSTALL ALL EQUIPMENT AND MATERIAL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 14. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACE, EQUIPMENT, IMPROVEMENTS, PIPING, ETC. AND IMMEDIATELY REPAIR ANY DAMAGE THAT OCCURS DURING CONSTRUCTION. 15. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS, ETC., IT MUST BE CLEARLY UNDERSTOOD THAT REINFORCING STEEL SHALL NOT BE DRILLED INTO, CUT OR DAMAGED UNDER ANY CIRCUMSTANCES (UNLESS NOTED OTHERWISE). LOCATIONS OF REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT. 16. REPAIR ALL EXISTING WALL SURFACE DAMAGED DURING CONSTRUCTION SUCH THAT THEY MATCH AND BLEND IN WITH ADJACENT SURFACE. 17. SEAL PENETRATION THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS. 18. KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITIONS AND FREE FROM PAINT SPOT, DUST, OR SMUDGES OF ANY NATURE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 19. MINIMUM BEND RADIUS OF ANTENNA CABLE SHALL BE IN ACCORDANCE WITH CABLE MANUFACTURER'S RECOMMENDATIONS. 20. DAMAGE TO EXISTING STRUCTURES AND/OR UTILITIES RESULTING FROM CONTRACTORS NEGLIGENCE SHALL BE REPAIRED AND/OR REPLACED TO THE OWNERS SATISFACTION AT NO ADDITIONAL COST TO THE CONTRACT. 21. ALL CONSTRUCTION IS TO ADHERE TOT-MOBILE'S INTEGRATED CONSTRUCTION STANDARDS UNLESS CALIFORNIA CODE IS MORE STRINGENT. 22. THE INTENT OF THE PLANS AND SPECIFICATIONS IS TO PERFORM THE CONSTRUCTION IN ACCORDANCE WITH THE CALIFORNIA BUILDING STANDARDS CODE (IF APPLICABLE, TITLE 19 AND 24 CALIFORNIA CODE REGULATIONS). SHOULD ANY CONDITIONS DEVELOP NOT COVERED BY THE APPROVED PLANS AND SPECIFICATIONS WHEREIN THE FINISH WORK WILL NOT COMPLY WITH THE REFERENCED CODE ON SHEET T-1.0, A CHANGE ORDER DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY THE JURISDICTION BEFORE PROCEEDING WITH THE WORK. SITE WORK NOTES: 1. DO NOT SCALE BUILDING DIMENSIONS FROM DRAWINGS. 2. SIZE, LOCATION, AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELY NOTED AND PLACED ON AS-BUILT DRAWINGS BY GENERAL CONTRACTOR AND ISSUED TO ARCHITECT OR ENGINEER OF RECORD AT COMPLETION OF PROJECT. 3. ALL EXISTING UTILITIES, FACILITIES, CONDITIONS AND THEIR DIMENSIONS SHOWN ON PLANS HAVE BEEN PLOTTED FROM AVAILABLE RECORDS. THE ARCHITECT OR ENGINEER OF RECORD AND OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR ACCURACY OF THE INFORMATION SHOWN ON THE PLANS OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION. CONTRACTOR SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORK SCHEDULES AND METHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES. 4 1 CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES BOTH HORIZONTAL AND VERTICALLY PRIOR TO START OF CONSTRUCTION. ANY DISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT OR ENGINEER OF RECORD FOR RESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BY THE ARCHITECT OR ENGINEER OF RECORD. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK AND EXPENSE. CONTRACTOR SHALL CALL LOCAL DIGGER HOT LINE FOR UTILITY LOCATIONS 48 HOURS PRIOR TO START OF CONSTRUCTION. 5. CONTRACTOR SHALL CLEAN ENTIRE SITE AFTER CONSTRUCTION SUCH THAT NO PAPER, TRASH, WEEDS, BRUSH OR ANY OTHER DEPOSITS WILL REMAIN. ALL MATERIALS COLLECTED DURING CLEANING OPERATIONS SHALL BE DISPOSED OF OFF-SITE BY THE GENERAL CONTRACTOR. 6 ALL SITE WORK SHALL BE CAREFULLY COORDINATED BY THE GENERAL CONTRACTOR WITH LOCAL UTILITY COMPANY, TELEPHONE COMPANY, AND ANY OTHER UTILITY COMPANIES HAVING JURISDICTION OVER THIS LOCATION. PAINTING NOTES & SPECIFICATIONS: A. GENERAL 1. ALL PAINT PRODUCT LINES SHALL BE SHERWIN WILLIAMS UNLESS SPECIFICALLY NOTED OTHERWISE. 2. CONTRACTOR SHALL PREPARE ALL SURFACES AND APPLY ALL FINISHES PER LATEST EDITION OF MANUFACTURER'S SPECIFICATIONS. 3. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS REGARDING SUFFICIENT DRYING TIME BETWEEN COATS WITH PROVISIONS AS RECOMMENDED BY MANUFACTURER FOR EXISTING WEATHER CONDITIONS. 4. FINISH COLOR AND TEXTURE OF ALL PAINTED SURFACES SHALL MATCH EXISTING ADJACENT SURFACES UNLESS OTHERWISE NOTED. 5. ALL PAINT MATERIAL DATA SHEETS SHALL BE PROVIDED TO THE T-MOBILE CONSTRUCTION MANAGER. 6. PREPARE PREVIOUSLY PAINTED SURFACE BY LIGHT SANDING WITH 400 GRIT SANDPAPER AND NON-HYDROCARBON WASH. PREPARE GALVANIZED SURFACES BY ACID ETCH OR SOLVENT CLEANING IN ACCORDANCE WITH SSPC-SP1. 7. FURNISH DROP CLOTHES, SHIELDS, MASKING AND PROTECTIVE METHODS TO PREVENT SPRAY OR DROPPINGS FROM DAMAGING ADJACENT SURFACES AND FACILITIES. 8. APPLY PAINT BY AIRLESS SPRAY, SANDING LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL COAT ON FLAT SURFACES. APPLY MATERIAL TO ACHIEVE A COATING NO THINNER THAN THE DRY FILM THICKNESS INDICATED. 9. APPLY BLOCK FILTER TO CONCRETE BLOCK CONSTRUCTION AT A RATE TO ENSURE COMPLETE COVERAGE WITH PORES COMPLETELY FILLED. 10. CONTRACTOR SHALL CORRECT RUNS, SAGS, MISSES AND OTHER DEFECTS INCLUDING INADEQUATE COVERAGE AS DIRECTED BY THE T-MOBILE CONSTRUCTION MANAGER. REPAINT AS NECESSARY TO ACHIEVE SURFACES WHICH ARE SMOOTH, EVENLY COATED WITH UNIFORM SHEEN AND FREE FROM BLEMISHES. B. COATING SYSTEM SPECIFICATIONS 1. DTM ACRYLIC COATING (SERIES B66) BY SHERWIN WILLIAMS CO. 1MIL OFT PER COAT APPLIED IN TWO COATS OVER DTM BONDING PRIMER (B66A50). 2. 100% ACRYLIC, LATEX COATING EQUIVALENT TO A-100 (SERIES A-82) BY SHERWIN WILLIAMS CO. 1 OFT PER COAT APPLIED IN TWO COATS OVER SPECIFIED PRIMER. PAINT & PRIMER ANTENNAS PRIMER-KEM AQUA E61-W525 TOPCOAT -COROTHANE II B65W200/B60V22 BTS CABINET PRIMER -KEM AQUA E61-W525 TOPCOAT -COROTHANE II B65W200/B60V22 COAXIAL JUMPER CABLES PRIMER-AS REQUIRED FOR ADHESION. APPLY ONE COAT OF KEM AQUA WATER REDUCIBLE PRIMER E61W25 REDUCED 25% TOPCOAT -2 COATS COROTHANE II POLYURETHANE B65W200/B60V2 RAW STEEL PRIMER -KEM BOND HS B50WZ4, DMT ACRYLIC PRIMER TOPCOAT -2 COATS COROTHANE II POLYURETHANE B65W200/B60V2 GALVANIZED METAL ACID ETCH WITH COMMERCIAL ETCH OR VINEGAR PRIMER COAT AND FINISH COAT (GALVITE HIGH SOLIDS OR DTM PRIMER/FINISH) STAINLESS STEEL PRIMER-OTM WASH PRIMER, B71Y1 TOPCOATS-2 COATS COROTHANE II POLYURETHANE B65W200/B60V2 PRE-PRIMED STEEL TOUCH UP ANY RUST OR UN-PRIMED STEEL WITH KEM BOND HS, SS0WZ4 ALUMINUM & COPPER PRIMER -DTM WASH PRIMER, B71Y1 TOPCOAT -2 COATS COROTHANE II POLYURETHANE B65W200/B60V2 CONCRETE MASONRY PRIMER -PRO MAR EXTERIOR BLOCK FILLER TOPCOAT -2 COATS A-100 LATEX HOUSE & TRIM, SHEEN TO MATCH CONCRETE STUCCO (EXISTING) 2 COATSA-100 LATEX HOUSE & TRIM, SHEEN TO MATCH STUCCO PRIMER -PRO MAR MASONRY CONDITIONED B-46 W21000 TOPCOAT -SUPERPAINT A-80 SERIES A-89 SATIN A-84 GLOSS WOOD PRIMER -A-100 EXTERIOR ALKYD W009D PRIMER Y-24W20 TOPCOAT -2 COATS A-100 LATEX HOUSE & TRIM SHEEN TO MATCH ADJACENT SURFACES FIELD CUTS/ DAMAGE (PRIOR TO PRIME & PAINT) FIRST & SECOND COAT -CUPRINOL CLEAR WOOD PRESERVATIVE #158-0356 ALL PENETRATIONS INTO FINISHED GLU-LAMS SHALL BE CAULKED WITH "SIKAFLEX" SEALANT STEEL TOUCH UP STEEL THAT HAS BEEN WELDED, CUT OR SCRATCHED IN THE FIELD SHALL BE TOUCHED UP WITH COLD GALVANIZED PAINT. GROUNDING NOTES: 1. COMPRESSION CONNECTIONS (2), 2 AWG BARE TINNED SOLID COPPER CONDUCTORS TO GROUNDING BAR. ROUTE CONDUCTORS TO BURIED GROUNDING RING AND PROVIDE PARALLEL EXOTHERMIC WELD. 2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN EACH SECTION AND LABEL EACH SECTION ("P", "A", "N", "I") WITH 1" HIGH LETTERS. 3. ALL HARDWARE 18-8 STAINLESS STEEL, INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. ALL HARDWARE SHALL BE STAINLESS STEEL 3/8 INCH DIAMETER OR LARGER. 4. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT WASHER BETWEEN LUG AND STEEL COAT ALL ' SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 5. NUT & WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE GROUNDING BAR AND BOLTED ON THE BACK SIDE. 6. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION ORIENTATION. PROVIDE AS REQUIRED. 7. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR TO AN EXISTING TOWER, THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO MOUNTING THE GROUNDING BAR TO THE TOWER. 8. ALL ELECTRICAL AND GROUNDING AT THE CELL SITE SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 780 (LATEST EDITION), CALIFORNIA BUILDING STANDARDS AND MANUFACTURER. BATTERY NOTES: 1. ANY CHANGES OR ADDITIONS TO BACK-UP BATTERIES SHALL NOT CONTAIN ELECTROLYTE QUANTITIES IN EXCESS OF 50 GALLONS AND NEED NOT COMPLY WITH THE REQUIREMENTS OF CALIFORNIA/INTERNATIONAL FIRE CODE (REFERRED TO IN T-1.0) SECTION 608 AS INDICATED IN SECTION 608.1 FIRE DEPARTMENT NOTES: 1. IF FIRE DEPARTMENT FINAL INSPECTION IS REQUIRED, SCHEDULE INSPECTION 2 DAYS IN ADVANCE. 2. A CALIFORNIA/INTERNATIONAL FIRE CODE PERMIT TO OPERATE BATTERY SYSTEMS WITH STATIONARY LEAD-ACID BATTERIES IS NOT REQUIRED FOR THE QUANTITIES ON SITE. 3. A CALIFORNIA/INTERNATIONAL FIRE CODE PERMIT MAY BE REQUIRED FOR THE HAZARDOUS MATERIALS ON SITE. 4. REQUIRED SIGNAGE SHALL INCLUDE LETTERING HEIGHT OF AT LEAST ONE INCH, IN A COLOR THAT CONTRASTS TO THE SIGN BACKGROUND, AND SHALL BE PROMINENTLY DISPLA YEO. 5. AN APPROVED METHOD TO NEUTRALIZE SPILLED ELECTROLYTE SHALL BE PROVIDED IN THE BATTERY ROOM. 6. BATTERIES SHALL BE PROVIDED WITH SAFETY VENTING CAPS. 7. CONTRACTOR SHALL VERIFY IN FIELD THE EXISTENCE OR INSTALLATION OF A FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A-10BC, WITH A CHARGE STATUS ACCEPTABLE TO THE LOCAL FIRE AUTHORITY HAVING JURISDICTION. 8. LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCEWITH THE UNIFORM FIRE CODE STANDARD 10-1 AND PLACEMENT IS SUBJECT TO APPROVAL OF THE FIRE INSPECTOR. 9. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE AND COMPRESSED GASES, AND OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS. 10. EXIT DOORS SHALL BE ABLE TO OPEN FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 11. ADDRESS NUMBERS SHALL BE A MINIMUM 6 INCHES HIGH AND PLAINLY VISIBLE FROM ROADWAY BUILDING IS ADDRESSED ON. 12. REQUIRED SIGNAGE SHALL INCLUDE, BUT MAY NOT BE LIMITED TO, APPLICABLE TYPES FROM EXAMPLES SHOWN HEREIN (SEE SIGNAGE IN T-3.0). 13. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE CONSTRUCTED SO AS TO MAINTAIN AN EQUAL OR GREATER FIRE RATING. 14. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION. [CALIFORNIA/INTERNATIONAL FIRE CODE 807.3] obile~ 10509 VISTA SORRENTO PKVVY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE. SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS REV_ DATE DESCRIPTION INITIALS 0 07/08/2020 90%CD's EC 1 07/14/2020 100% CD's EC ,111:,s'E..O ~Re~~ , 00------•••• " " 1/J-~ ~ tf v -" · •. o/\'\ I • ' . " ' ~ • 1 • [ti. • IJESTO T. POPOWYC • I . ~ " * • c.-27496 • * • REN ~WAL 4-30-19 • ~ • '\) r] I I lAll.: t <.f ~' •0 v j IJl/ff_..._ -.:v~.__,-~ '<1 /';..~" .. ~ ••• _: ~~,, ~ ' ( IL • I\"'\ \\ j-l'fc: "I HER~ ,1,J.W:.;,ER .. E--1""1-PR~~;~~~~y DIRECT 2_S SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE GENERAL NOTES SHEET NUMBER T-2.0 ci UJ >-a, 'i: 0 a:: Q_ >-~ t; °' >-en en en UJ 0 ~ UJ en c:: UJ °' 2e 0 0 >-en UJ 5 UJ "' I 0 ~ ~ I >-z "" I >- "' UJ I :s UJ "' ::::, en 0 ~ 0 en 0 c:: 0 w <f> ::::, >-z ..,: w "' ::::, ~ z >-"' >-"' "" >-w °' Q_ 0 a:: Q_ <f> r" z UJ ,, ::::, g 5 ti ::::, a:: >-if> z 0 0 "-0 >-UJ <f> S2 I >-z 0 w z i (.) z 0 ~ ,, "' NO TICE Radio frequency fields beyond (<t) this point may exceed the FCC general public exposure limit. Obey all posted signs and site guidelines for working in radio frequency environments. In accordance with Federal Communications Commission rules on radio frequency emissions 47 CFR 1.1307 (b) A VISO Los campos de frecuencias de <•1 radio a partir de este punto podr8n exceder el Ii mite del cual el FCC permite que el pUblico en general podr3 estar expuesto Obedezca todas las sel'iales indicadas y las guias del sitio para trabajar en tos ambietes de frecuencia de radio. D!! a~eroo a las reg las de la Comisi6n Feden:,I Col'l'K;nlcac::!oncs {FCC) sobrc las omlsioncs do lroc:uon::::las do radio 47 CFR 1.1307(b) &CAUTION Beyond this point: Radio frequency flelds at ~ this site may exceed FCC rules for human exposure. For your safety, obey all posted signs and site guidelines for working in radio frequency environments. In accord;;.mcewith Federal Comm-inieations Commission rules on radiolrequency emissions 47 CFR 1.1307 (bl AATENCION A partir de este lugar: Los campos de frecuencias de radio en este sitio podr3n exceder & el limite del cual las reglas dcl FCC permiten que esten expuestos los humanos. Por su s:egurid3d. obedezca todas las sBi'talas indicsd.is y las guias del s:itio par11 tr::ibajar en lo~ ombientes de frecuencia de r3dio. De aeuo~o a las reglaa do la Comisi6n Fodoral Comuni:::Hc:iones (FCC) sob.e las ornisiones de rrocue~cia,. de l'l!dlo 47 CFR 1.1307(b) &WARNING Beyond this point: Radio frequency fields at this site may exceed FCC rul es for human exposure . Failure to obey all posted signs and site guidelines for working in radio frequency environments could result in serious injury. In aeeoroanco witn Fee oral Gomrr,unlcatl:in8 CommlMlori n;lo, on radio 1requoncy emiasicm5 47CFR 1.1307(tl) RTENaA A partil" de este lugar: Los campcs de frecuencias de radio en este sitio exceden el limite del cual las reglas del FCC permlten que esten e~pu&stos los humanos. El no obedozca lodas las sal'ia les indicadas y las guias del sitio para trabajar en los ambi0n1as de froeuoncia da radio, poCria re.sultar en gravos lesiones. Oo acoordo a Ii,$ ro:;ilas do la Com:si6n Federal Comunic.icKmc~ (!'CC) ocl:,ro l,1s c,risiones do frocu:mda~ do radio <l7 C!'R 1 .1307(b) ALERT ING SIGNS £NOTICE~ GUIDELIN ES FOR WORKING IN RADIOFREQUENCY ENVIRONMENTS & All personnel should have electr omagnetic energy (EME) awareness training. & A ll personnel entering th is site must be authorized. & Obey a ll posted signs. £ Assume all antennas are active. £ Before working on antennas, notify owners and disable appr opiate transmitter. & Mant a in m inimum 3 feet clearance from all antennas. & Do not stop in front of atennas. .&._ Use personal RF monitors whlle working near atennas. .£.. Never operate transmitters w ithout shields during normal operation. .£ Do not operate base station antennas in equipment room . HAZARDOUS MATERIAL .__,,,,._.STORAGEAREA WARN ING THIS FACIL ITY CONTAINS CORROSIVE LIQU ID TOXIC LIQU ID CLASS 1 WATER REACTIVE LIQU ID IN CASE OF EMERGENCY CALL 1-888-662-4662 SITE NUMBER: SITE NAME: SD069 18A FARADAY EXECUTIVE CTR INFORMATION SIGN <l'. I' 0.. ~ -' (") ~©) UJ er: (J) 0 0 I-Q_ (.) 0 UJ er: (J) 0.. 0 □ <l'. 0 :r:O 0.. " -' (") <l'. ©) (_') a:: zo I-1- U) u -UJ ~ U) 00 00 00 00 00 00 00 00 00 00 LEGEND DETAIL REFERENCE ELEVATION REFERENCE SECTION REFERENCE AZIMUTH ARROW ELEVATION BUBBLE MECHANICAL GRND. CONN. CADWELD GROUND BUS BAR EXISTING T-MOBILE PANEL ANTENNAS PROPOSED T-MOBILE PANEL ANTENNAS T-MOBILE RADIO T-MOBILE TMA LINE TYPES PROPERTY LINE CENTER LINE FIBER CABLE ---G---GROUNDING CABLE ---x---CHAIN LINK FENCE --□--WOOD FENCE • CONSTRUCTION DRAWINGS: SD06918A_Other_SD06918A_Approved SCR_ZDs-1; MITCHELL J ARCHITECTURE, INC 08-20-1012 • SCOPE OF WORK: SD06918A_Anchor_8_signed_2020-06-11 • SITE SURVEY: N/A • SITE WALK 05/1512020 • BATTERY INFORMATION : SD06918A_Other_SD06918A Site Survey Form_Solex REFERENCED DOCUMENTS SCALE N.T.S. SCALE N.T.S. PARCEL 1 AND 2 OF PARCEL MAP NO. 16317, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO , STATE OF CALIFORNIA, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, DECEMBER 6, 1990 AS FILE/PAGE NO. 90-652174 OF OFFICIAL RECORDS 4 3 ABBREVIATION DEFIN ITION A.B. ANCHOR BOLT GRND. GROUND ABV ABOVE HDR. HEADER AC AIR CONDITIONING HGR. HEIGHT ACU AIR CONDITIONING UN IT ICGB. ISOLATED COPPER GROUND BUS ACCA ANTENNA CABLE COVER ASSY. IGR INTERIOR GROUND RING ADD'L ADDITIONAL IN. (") INCH(ES) A.F .F. ABOVE FIN ISHED FLOOR INT. INTERIOR A.F.G. ABOVE FIN ISHED GRADE LB.(#) POUND(S) A.G.L. ABOVE GRADE LEVEL L.B. LAG BOLTS ALUM. ALUMINUM L.F. LINEAR FEET (FOOT) ALT. ALTERNATE L. LONG (ITUDINAL) ANT. ANTENNA MGB MASTER GROUND BUS APPRX. APPROXIMATE(L Y) MAS. MASONRY APX APEX MAX. MAXIMUM ARCH. ARCHITECT(URAL) M.B. MACHINE BOLT ASSY. ASSEMBLY MECH. MECHANICAL AWG. AMERICAN WIRE GAUGE MFR. MANUFACTURER BCN BEACON MIN. MINIMUM BD. BOLLARD MISC . MISCELLANEOUS BDK BRASS DISK MTL. METAL BLDG. BUILDING MW MICROWAVE BLK. BLOCK (N) NEW BLKG. BLOCKING NO.(#) NUMBER BM BEAM I BENCH MARK N.T.S. NOTTO SCALE B.N. BOUNDARY NAILING O.C ON CENTER BTCW. BARE TINNED COPPER WIRE OH. OVERHEAD B.O.F. BOTTOM OF FOOTING OHP OVERHEAD POWER LINE BTM . BOTTOM OPNG. OPENING BRC. BRACE P/C PRE CAST CONCRETE BTS BASE TRANSCEIVER STATIO N PLY. PLYWOOD B.W.F. BARBED WIRE FENCE PPC POWER PROTECTION CABINET BIU BACK-UP CABINET P.S.F . POUNDS PER SQUARE FOOT CAB. CABINET P.S.I. POUNDS PER SQUARE INCH CANT CANTILEVER(ED) P.T. PRESSURE TREATED CLP. CAST IN PLACE PWR. POWER (CABINET) C.L.F. CHAIN LINK FENCE QTY. QUANTITY CLG. CEILING R. RADIUS CLR. CLEAR RAD.CTR. RADIATION CENTER COL. COLUMN RBS RAD IO BASE STATION CONC. CONCRETE REF. REFERENCE CONN. CONNECTION(OR) RE INF. REINFORCEMENT(ING) CONST. CONSTRUCTION REQD . REQUIRED CONT. CONTINUOUS RF RADIO FREQUENCY CPD CONCRETE PAD RGS RIGID GALVANIZED STEEL C.T. CABLE TRAY RRU REMOTE RADIO UNIT d PENNY (NAILS) RRH REMOTE RADIO HEAD DBL. DOUBLE SCH. SCHEDULE DEF. DEFINITION SHT. SHEET DEPT. DEPARTMENT SIM. SIMILAR D.F. DOUGLAS FIR SPEC. SPECIFICATION(S) DIA. (0) DIAMETER SP STEEL PLATE DIAG. DIAGONAL SQ SQUARE DIM. DIMENSION S.S. STAINLESS STEEL DR. DOOR STD. STANDARD DWG. DRAWING(S) STL. STEEL DWL. DOWEL(S) STRUC. STRUCTURAL EA. EACH T.B.D. TO BE DETERMINED EBX ELECTR ICAL BOX T.B.R. TO BE RESOLVED EG EQUIPMENT GROUND TEMP. TEMPORARY EGR EQUIPMENT GROUND RING THK . THICK(NESS) EL. ELEVATION TMA TOWER MOUNTED AMPLIFIER ELEC. ELECTRICAL T.N. TOE NAIL ELEV. ELEVATOR TO.A. TOP OF ANTENNA EM ELECTRICAL METER T.O.C. TOP OF CURB E.M.T. ELECTRICAL METALLIC TUBING T.O.F TOP OF FOUNDATION E.O.P. EDGE OF PAVEMENT TOP TOP OF PLATE (PARAPET) EQ. (=) EQUAL T.O.S. TOP OF STEEL EVLT ELECTRICAL VAULT T.O.W. TOP OF WALL ENG. EXPANSION TWR. TOWER EXST. EXISTING TYP. TYPICAL EXT. EXTERIOR U.G. UNDER GROUND FAB. FABRICATION(OR) U.L. UTILITY POLE F.N. FINISH FLOOR U.N.O. UNLESS NOTED OTHERWISE F.O. FINISH GRADE V.I.N. VERIFY IN FIELD FIN. FINISH(ED) W. WIDE(WIDTH ) FLR. FLOOR WD. WOOD FDN. FOUNDATION WP. WEATHERPROOF F .. C. FACE OF CONCRETE VVT. WEIGHT F .. M. FACE OF MASONRY F .. S. FACE OF STUD F .. W. FACE OF WALL F.S. FINISHED SURFACE FT.(') FOOT(FEET) FTG. FOOTING GA. GAUGE GI GALVANIZE(D) G.F.I. GROUND FAULT INTERRUPTER GEN GENERATOR GLB. GLOBAL POS ITIONING SYSTEM GRC. GROVVTH RADIO CABINET i:21-------------------------------------------....----------..--+------------------------------------..-:-:--'.:-:--::--,--t-----------------------------,--;;-;::-;-;-;::-,-1 : SIGNAGE SCALE 5 LEGAL DESCRIPTION SCALE 2 ABBREVIATIONS SCALE 1 >-L-----------------------------------------'--N-T-.S;,;·....ii....-i....---------------------------------..... N-._T_.s_ ...... _ .... _____________________________ N_T_.s_. __ _ ~ · ·Mobile· REV. 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM J WIRELESS SAC AE DESIGN GROUP, INC. 5015 SHOREHAM PLACE. SUITE 150 SAN DIEGO. CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07 /0812020 90% CD's 1 07 /1412020 100% CD's ESTO T POPOWYC -27496 REN WAL 4-30-19 • • • INITIALS EC EC ·* • • = ~ = ~ = fl-"----1 : ""I HER WERE c...., PREPARED MY DIRECT c:, SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA"" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE ABBREVIATIONS, LEGAL DESCRIPTION, REFERENCED DOCUMENTS, LEGEND & SIGNAGE SHEET NUMBER T-3.0 w 0:: ::> (f) g u (f) 15 0:: 0 w ~ >-z <( w 0:: ::> ';;: z iii i c:: a. 0 0:: a. SQ ~ z w " ::, 8 0 z Q t3 ::> 0:: ~ 15 C, ~ -~ ~ ~ ~ ~ X 1/ X ~ ~ 2/ \ I I I I I I ' I I I I ~ OVERALL SITE PLAN >- ~ ~ ~ v \__ EXISTING 1 BUILDING i_ ------ I \ \ \__ EXISTING . BUILDING\ I I \ \ \ I I I \\ ' \ \ \ \ \ DISCLAIMER • THIS SITE PLAN WAS GENERATED WITHOUT THE BENEFIT OF A SURVEY. LOCATIONS OF PROPERTY LINES AND UTILITIES ARE PRELIMINARY. \__ EXISTING \ BUILDING -1... tv~ ¼Pv~ 5 l;zllI @ 20' 40' +FM fr: HW/'1 NORTH SCALE: 1 "=40'-0" (22x34) (OR) 1/2"=40'-0" (11x17) 1 REV. 0 1 ~ ma ·Mobile· 1 D509 VISTA SORREN~O PKWY #2D6 SAN DIEGO. CA 92121 T-MOBILE.COM J WIRELESS SAC AE DESiGN GROUP, INC. 5015 SHOREHAM PLACE. SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION INITIM.S 07/08/2020 90% CD's 07/14/2020 100% CD's • • • • EC EC T. POPOWYC -27496 ·* REN WAL 4-30-19 • • "I HER PREPARED B R MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE OVERALL SITE PLAN SHEET NUMBER A-1.0 Cl w >-ai ~ "' 0. :::; ~ ~ U) U) w 0 ~ w U) a:: w ii: 5 ~ U) ~ w "' I u ~ ~ z ~ >-er: w I 0 w "' ::, g u U) 5 "' 0 w U) ::, >-~ w a:: ::, " z ~ ~ w ii: 0. ~ 0. !!2 ~ z w :,, ::, 0 0 0 z Q >-u ::, a:: !;, z 0 0 15 ti U) U) :i: >-z Cl w z NOTE: REMOVE T-MOBILE EXISTING CABLE ENTRY PORT HOOD NEAR PANEL ANTENNAS, (3) TOTAL -- o~~ /'\ I +---B ----PROPOSED T-MOBILE BETA AV I SECTOR CABLE TRAY V (APROX. LENGTH ±60'-0") 00 ' @ Ao0 L ~ ,_ 0 - . - T l I ! I ·I \ I .. I I • I I I I I I C I_ v<) □□□□:J □□□□□□□□□□□□CJl)v □-~a-.------------------Di , ~ ----EXISTING COAX CABLE RUN THROUGH 3RD FLOOR CEILING TO ANTENNA LOCATIONS TO BE REMOVED '- '- ' PROPOSED T-MOBILE ALPHA --------f021-"-+ SECTOR CABLE TRAY (APROX. LENGTH ±60'-0") 0 □ ~ ~--EXISTING ROOF MOUNTED □ 1 CONDENSER UNITS, TYP. 0 r--"'-, I □ ~ □~ --EXISTING ACCESS HATCH @ --~-::-->~"J I" ·.· .. -cc-'-·., /',,. ,,,_,,_,.•,' ,,I _B □□c:::L_ □ --EXISTING T-MOBILE ROOF MOUNTED CONDENSER UNITS PROPOSED T-MOBILE CABLE >· m > . . I ENTRY PORT HOOD, (1) TOTAL i:f,/ :; •••·•·· 1 @ 1'. / ·.·· E:l:TING T-MOBILE EQUIPMENT __ ,,,~: ~ ... i<L~S>J ROOM LOCATED ON FIRST FLOOR/ OF EXISTING THREE STORY COMMERCIAL BUILDING @@ c:. '- - -PROPOSED T-MOBILE GAMMA 0 SECTOR CABLE TRAY (APROX. LENGTH ±100'-0") - @ '- , ~ 0 . ~ □ □ □ □ □ □ □ □ □ C r D tJ===:Z:::/2 \__ EXISTING ~ ATRIUM WITH \._ ) .I ELEVATORS i--------------EXISTING ROOF WALKING PADS □ □ J J □ □ □ □ □ \._ EXISTING \ BUILDING \., □0 □ ()Q (} -__,/ □ 1/, 0 □ ' H--+--t-+-+--+--+---1 ! 6 ~ !:;: "'Ill IP ~ i NORTH 5'.l---------------------------------------"="'===±~==±=±±=e=!=±=±=d...-------------------------------------------------------------,--------,------:-=:-,-c-:-::-::c-:-:C"'.7"-,---1 z Q 3' 6' 12' SCALE: 3/32"=1 '-0" (22x34) ~~E:N~L:A~R~G~E~D~R~O~O~F~P~LA~N~--------------------------------------------------------------------L!::,~r~!~0 :m":"~1jJ(o~R~l::::E3ffi~4'~'1~·~~"](1~1x~17[1j__ 1~ REV. t.F e -Mobilemm 10509 VISTA SORRENTO PKWY #206 SAN DIEGO. CA 92121 T-MCBIL:.COM S,A,CAE DES1GN GROUP, lNC. 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO. CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION INITIALS 0 07/08/2020 90% CD's EC 1 07/14/2020 100% CD's EC ,,,!~~~~-~-~~li1i;~ ,f ~ -' •• '0~ ''v . ,,>,."" I • ' . . ' •• ~ESTO T. POPOWYC, •. • • * • :::-27496 • * • REN :WAL 4-30-19 • .ll\ /I'\ lA" : l oJ ~ '•Q< ~} I / IU"j~~,-,,1,l,1--~ <1~•· •• -~'' --1 / J::--• • • • • _,,,,. ~-... , ~ ,()c, ·I\\ " ·n,c• ··1 HER ~~]il,lj!\ C& WERE PREPARED B~~ffi'MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA•' L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE ENLARGED ROOF PLAN SHEET NUMBER A-2.0 RAD . TOP OF· GENERAL POSITIO.N SECTOR AZIMUTH CENTER ANTENNA ANTENNA SIZE EXISTING OR PROPOSED ANTENNA MODEL TMA/RADIO CABLE CABLELENGTH · ASPERRFDS 34'-6" 36'-0" ALPHA 340° 37'-6" 35'-6" NIA 35'-6" 36'-0" BETA 110' 37'-6" 34'-6" NIA 34'-6" 36'-0" GAMMA 230' 37'-6" 35'-6" NIA DELTA NIA NIA NIA ALPHA 340' 351-611 37'-6" BETA 110° 35'-6" 37'-6" GAMMA 230' 35'-6" 37'-6" DELTA NIA NIA NIA 6' -011 1 PROPOSED 2 PROPOSED 4'-0" 3 PROPOSED NIA 4 NIA APXVAARR18_ 43-U-NA20 AIR6449_B41 AIR32 KRD901146-1_B66_B2A NIA (1) RADIO 4449_871+B85 (1) RADIO 4415_825 NIA NIA NIA (4) COAX JUMPER (8) SU REFLEX JUMPERS (1) 6X12 HCS 4AWG (4) FIBER JUMPERS (1) 3X6 HCS (4) FIBER JUMPERS (1) 6X12 HCS 4 AWG NIA 16'-0" 8'-0" 70m 16' -0" ?OM 16'-0" 70M NIA AIR32 (4)FIBERJUMPERS 16'-0" ,--PROPOSED PIPE-TO-PIPE CLAMP SET BY VALMONT P/N: ACPOSK OR APPROVED EQUAL, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) 4'-0" 1 PROPOSED NIA ( 6X H 4AWG 1------l-----1------+--K-R_D9_o_11_4_6-_1 __ B6_6 __ B_2_A-+--------+-1-) _12_cs ___ 1--__ s_o_M_----j PROPOSED T-MOBILE -----H',+----~--+ PROPOSED ANTENNA FRP SKIRT, TEXTURED & -,----..._ PAINTED TO MATCH EXISTING BUILDING, TYP. -----\--.----,.-+-ALL SECTORS ~ ±2'-1"~ (4) FIBER JUMPERS 16'-0" GAMMA SECTOR (1) 3X6 HCS 90M CABLE TRAY (APROX. 31-011 2 AIR6449_B41 PROPOSED NIA 1------1-----1------+---------+--------+---------t---------J LENGTH ±100'-0") (4) COAX JUMPER 16'-0" @ ....,-,,-PROPOSED T-MOBILE AIR32 PANEL ANTENNA MOUNTED TO PROPOSED ANTENNA MOUNT, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) 6' .. Q" NIA 6'-0" 3'-0" 4'-0" NIA NIA NIA NIA NIA · ·• GENERAL ANTENNA SIZE 41.011 4'-0" 4'-0" 4'-011 4'-0" 4'-011 41-011 41-011 4'-0" 4'-011 41-0" NIA NIA NIA NIA 3 4 1 2 3 4 NIA NIA NIA NIA 1 2 3 4 1 2 3 4 1 2 3 4 NIA NIA NIA NIA PROPOSED NIA PROPOSED PROPOSED PROPOSED NIA NIA NIA NIA NIA APXVAARR18_43-U-NA20 NIA APXVAARR18_ 43-U-NA20 AIR6449_B41 AIR32 KRD901146-1_B66_B2A NIA NIA NIA NIA NIA cEXISJ;ING OR=•• ANTENNA MODEL PROPOSED EXISTING TO BE REMOVED EXISTING TO BE REMOVED EXISTING TO BE REMOVED AIR21 KRC118023-1_B2P _B4A PANEL ANTENNA PANEL ANTENNA EXISTING TO BE AIR 21 REMOVED KRC118023-1_B2P _B4A EXISTING TO BE REMOVED EXISTING TO BE REMOVED EXISTING TO BE REMOVED EXISTING TO BE REMOVED EXISTING TO BE REMOVED EXISTING TO BE REMOVED EXISTING TO BE REMOVED AIR21 KRC118023-1_B2P _B4A PANEL ANTENNA PANEL ANTENNA AIR21 KRC118023-1_B2P _B4A AIR 21 KRC118023-1_B2P _B4A PANEL ANTENNA PANEL ANTENNA EXISTING TO BE AIR 21 REMOVED KRC118023-1_B2P _84A NIA NIA NIA NIA NIA NIA NIA NIA (1) RADIO 4449_871+885 (1) RADIO 4415_825 NIA (1) RADIO 4449_871+885 (1) RADIO 4415_825 NIA NIA NIA NIA NIA NIA NIA (1) TWIN AWS (4) TRX NIA NIA NIA (1) TWINAWS (4) TRX NIA N/A NIA (1) TWINAWS (4) TRX NIA NIA NIA NIA NIA NIA NIA (8) SU REFLEX JUMPERS 8'-0" 2 -5.1 (1)6X12HCS4AWG 90m NIA (4) COAX JUMPER (8) SU REFLEX JUMPERS (1)6X1ZHCS4AWG (4) FIBER JUMPERS (1) 3X6 HCS (4) FIBER JUMPERS (1) 6X12 HCS 4 AWG NIA NIA NIA NIA NIA NIA 16'-0" 16'-0" 80m 16' -0" 80M 16'-0" SOM NIA NIA NIA NIA NIA ±2'-0" ±2'-311 ±21.311 ~ ±2'-3" r-:;:;.--Jt-PROPOSED T-MOBILE RADIO 4449 B71 +B85, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) ~ PROPOSED T-MOBILE AIR6449 PANEL ANTENNA ++-+----~ MOUNTED TO PROPOSED ANTENNA MOUNT, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) ~ _______,._ PROPOSED T-MOBILE RADIO 4415_825, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) ~ '---I-EXISTING ANTENNA MOUNTS TO REMAIN, (12) TOTAL (4) PER SECTOR (TYP. OF ALL SECTORS) rc..L.L'f-"LL"--y~c'::'::::¥=''=f-PROPOSED T-MOBILE APXVAARR18 PANEL ANTENNA MOUNTED TO PROPOSED ANTENNA MOUNT, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) ~ +-------¥,-'.,+----PROPOSED T-MOBILE BETA SECTOR CABLE TRAY (APROX. LENGTH ±60'-0") @ NORTH PROPOSED ANTENNA PLAN 0 1' 2' 4' biwJiWi"'·,\ & &k @-1 SCALE: 1I4"=1'-0" (22x34) (OR) 1I8"=1'-0"(11x17) 2 CABLE (4)1-5/8" COAX (4) FIBER JUMPER (1) 3X6 HCS NIA NIA (4)1-5/8" COAX (1) FIBER JUMPER (4)1-5/8" COAX (4) FIBER JUMPER (1) 3X6 HCS NIA NIA (4)1-518" COAX (1) FIBER JUMPER (4)1-5/8" COAX (4) FIBER JUMPER (1) 3X6 HCS NIA NIA (4)1-518" COAX (1) FIBER JUMPER NIA NIA NIA NIA 9'Ji.$LE~ENGJH · As P;ER R.FDS ·• 203"-0" 16'...Q" ?OM NIA NIA 203'-0" 16'-0" 271'-0" 16'-0" 90M NIA NIA 271'-0" 16'-0" 242'-0" 16'-0" 80M NIA NIA 242'-0" 16'-0" NIA NIA NIA NIA ±1'-10" ±1'-4" "°1~/-=::'....-.---,--EXISTING T-MOBILE AIR21 PANEL ANTENNA ~ MOUNTED TO EXISTING ANTENNA MOUNT TO BE REMOVED, (6) TOT AL (2) PER SECTOR (TYP. OF All SECTORS) ,,---t---EXISTING T-MOBILE PANEL ANTENNAS MOUNTED TO EXISTING ANTENNA MOUNTS TO BE REMOVED, (6) TOTAL, (2) PER SECTOR (TYP. ALL SECTORS) ,,--EXISTING ANTENNA MOUNTS TO REMAIN, (12) TOTAL (4) PER SECTOR (TYP. OF ALL SECTORS) m,,__ ____ EXISTING BUILDING ±2' ±1'-4" NORTH REV 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07 /0812020 90% CD's 1 0711412020 100% CD's T. POPOWYC 7496 -30-19 INfTIAf.S EC EC • ·* • • ~; ,., I c, ~, = ----11"" WERE PREPARED R MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EXISTING & PROPOSED ANTENNA PLANS & SCHEDULES SHEET NUMBER A-3.0 >--u 0 SCALE o 1' 2' 4' SCALE: 1I4"=1'-0" (22x34) ~ ... L.;_P.:,;R:,:O:,:_P_:O_:S,:E:D_;:&:,.:E:X.::,IS:,T,;,_;l,;,_;N,:G.,;,.A,;;.N;_;,T,:E,;,_;N,;_;N~A.,:S;,:C~H;,:E;,:D,:U.:,L:,ES:..., ____________________ ..J....:.:.~.1..,.3...1,._E_x_1s_r_1 N_G_A_N_T_E_N __ N_A_P_L_A_N __________________ ......,...,...i.......'"" .. " . .i_·,,_·Lw_,,, .... ,w .... •I ...i....(...,oR ... l ....... 1I8 .. "=_1·-_o"" ... (1_1x1_?J ...... .__1_. .._ _________ _, N.T.S. - ------------- ci w r-m :i: 0 "' Q_ ':; 0 °' t; UJ UJ w u ~ PROPOSED MOUNTING PIPE 2 STD. A53 GRADE B, 5'-0" LONG ATTACHED TO EXISTING MOUNTING PIPE PROPOSED WIRE MESH -~ FOR VENTILATION TO BE INSTALL TOP & BOTTOM (TYP. ALL FRP BOXES) ~ A. "' w °' "' 5 0 r- UJ w 5 il! PROPOSED CABLES PER -~ i's ANTENNA SCHEDULE i@ r--3.0 :2 r-z PROPOSED ANTENNA FRP ----~ ~ SKIRT, TEXTURED & PAINTED "' !j! TO MATCH EXISTING BUILDING, ti TYP. ALL SECTORS w !@ u UJ i5 "' 0 UJ UJ ::, ~ <( ui "' ::, \c z iii ~ w °' {l_ 12 Q_ UJ UJ ~ UJ :. ::, 8 0 z 0 ti ::, "' t; z 8 "-0 r-UJ UJ UJ :i: r-z ~----------PROPOSED PIPE-TO-PIPE CLAMP SET BY VALMONT P/N: ACP08K OR APPROVED EQUAL, (3) TOTAL, (1} PER SECTOR {TYP. ALL SECTORS) @ PROPOSED WIRE MESH ---- FOR VENTILATION TO BE ,,..----F ---INSTALL TOP & BOTTOM ---~--------- . ! . ! .1.. ./ . : L ... : / 0 ' . I LI.-/ / . / ' . . . ; . ' / / ' / (TYP. ALL FRP BOXES) PROPOSED T-MOBILE -----t-t AIR6449 PANEL ANTENNA MOUNTED TO PROPOSED ANTENNA MOUNT, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) @ ...-----AIR ANTENNA PIPE MOUNTING KIT, INCLUDED WITH ANTENNA; INCLUDES (2) CLAMP SETS @ PROPOSED CABLES PER --~ ANTENNA SCHEDULE @ PROPOSED ANTENNA FRP ------<----, SKIRT, TEXTURED & PAINTED TO MATCH EXISTING BUILDING, TYP. ALL SECTORS @ ._____ PROPOSED T-MOBILE AIR32 PANEL ANTENNA MOUNTED TO PROPOSED ANTENNA MOUNT, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) @ PROPOSED MOUNTING PIPE 2 ___ ____, STD. A53 GRADE B, 4'-0" LONG ATTACHED TO EXISTING MOUNTING PIPE --PROPOSED PIPE-TO-PIPE CLAMP SET BY VALMONT P/N: ACP0BK OR APPROVED EQUAL, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) @ I I : I . I I I I . . i . : . I ' I . l . I I / / ~ AIR32 PANEL ANTENNA AIR6449 PANEL ANTENNA ~ z 0 0 ~ ~ ls PROPOSED PIPE-TO-PIPE CLAMP ---- SET BY VALMONT PIN: ACP0BK OR APPROVED EQUAL, (3) TOTAL, (1) PER SECTOR (TYP. All SECTORS) @ PROPOSED MOUNTING PIPE 2 ----t--~ STD. A53 GRADE B, 6' LONG ATTACHED TO EXISTING MOUNTING PIPE PROPOSED T-MOBILE ----..-., APXVAARR18 PANEL ANTENNA MOUNTED TO PROPOSED ANTENNA MOUNT, (3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) @ PROPOSED CABLES PER ---+-..+ ANTENNA SCHEDULE @ PROPOSED ANTENNA FRP ----+-~-..., SKIRT, TEXTURED & PAINTED . f .~-,--r I' TO MATCH EXISTING BUILDING, TYP. ALL SECTORS @ i----F : l,, ,,-----PROPOSED WIRE MESH FOR VENTILATION TO BE INSTALL TOP & BOTTOM (TYP. All FRP BOXES) . ' !/ _/;;>/ ' / / \ . , // i / . ,i,, . ...,....+-cr--cr--c'-+--+--+-+-+--EXISTING MOUNTING · I· . . . . I. ' / / 0 / / / / / / / . / / PIPE ATTACHED TO EXISTING BUILDING TO REMAIN APXVAARR18PANELANTENNA u.---------------------------------------------------------------------------------------------------------,---------.----------,----,---11 2 o 2" 4,, 8" SCALE: 1-1/2"=1'-0" (22x34) ~ ANTENNA MOUNTING DETAIL k,-,,,"'"'1@wm•,,I (OR) 3/4"=1'-0" (11x17) ---------------------------------------------------------------------------------------------------------------------------1 bile~ REV. 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07/08/2020 90% CD's 1 07/14/2020 100% CD's INITIALS EC EC • .POPOWYC 7496 4-30-19 ·* e • PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE ANTENNA MOUNTING DETAIL SHEET NUMBER A-3.1 ci w I-m 'i: 0 :l: § ii' J-u:, u:, u:, w 0 ~ w u:, a:: w ii' a:: ;'j s 3l ~ w a:: I u ~ i I- ~ I J- c:: w I 15 w a:: ::, ~ _, u u:, 0 a:: 0 w u:, ::, >-z -< w a:: ::, ~ z fu i\:: j:: w ii' o._ 0 c:: o._ u:, [:! z w " ::, u 0 D z 0 ti ::, c:: J-u:, z 8 LL 0 1-w u:, u:, i" z D w z ~ z 8 z 0 ~ a:: PROPOSED T-MOBILE RADIO 4415_825, (3) -~ TOTAL, (1) PER SECTOR (TYP. All SECTORS) ~ PROPOSED RADIO SLED, TYP. --~ ALL SECTORS @ EXISTING ROOFTOP --~ i-------PROPOSED CABLES PER ANTENNA SCHEDULE @ l '-----F---F--F F - PROPOSED T-MOBILE RADIO 4449 --, 871+885, (3) TOTAL, (1) PER SECTOR (TYP. All SECTORS) ~ PROPOSED RADIO SLED, TYP. --~ ALL SECTORS @ EXISTING ROOFTOP --~ i-------PROPOSED CABLES PER ANTENNA SCHEDULE @ l '-----F--F--F F - ~n-----------------------------------------------------------------------------------------------------------------~--------------------1 SCALE: 1/2"=1'-0" (22x34} w i" RADIO MOUNTING DETAILS 0 6" 1' 2' l"'iilJJWP#m¾ii&Wri-;d (OR) 1/4"=1'-0" (11x17) 1 REV. 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION INITIALS 0 07/08/2020 90% CD's EC 1 07/14/2020 100% CD's ESTO T. POPOWYC -27496 REN WAL 4-30-19 EC .-:"'::'I ("•,J c, "' .,, ~:.;...--a..., "I HER E I-- PREPARED R MY DIRECT 5 SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE RADIO MOUNTING DETAILS SHEET NUMBER A-3.2 0 w I-m :c 0 "' a. ::; ti "" t; ~ "' w 0 1i' w "' "' w "' ~ 0 1- r::i 5 w "' I 0 NOTE: NO NEW BATTERIES TO BE ADDED EXISTING BATTERY SPECIFICATIONS CABINET #1 TYPE PBC 6200 BATTERY MANUFACTURER NORTHSTAR MODEL NUMBER: NSB100FT RED MAX CAPACITY IN AMPHOUR 100 NUMBER OF BATTERIES INSTALLED 9 MAXIMUM NUMBER OF BATTERIES PER CABINET 20 TOTAL CAPACITY IN KWH IN CABINET#1 10.800 CABINET #2 TYPE RBS 5000 BATTERY MANUFACTURER BATTERY CORP MODEL NUMBER: BC012V26FT / EXISTING HALLWAY~ Vr/ / /1 V / / / / / / / // //1-·~/-~/_.·~···~ ,.·_··~· --~/.---'---·'-----'-//~//~~./··_·,_,_.~/'---'-//-'-,---"-II/ .. EXISTING SMOKE DETECTOR, FIRE ----------1-,LU / ~/ EXTINGUISHER, EYE WASH STATION V: D AND ENVIRONMENTAL KIT '/ n===cfe----¥--+-----EXISTING CABLE LADDER r/ vv ~ ~/-/'-/'/_/_/'/------'// Q ~ EXISTING19"EQUIPMENTRACK / r -V /e--_ ~~~lhi-/ EXISTING CIENA CABINET -----~_J tt-'i-t,L--t----INSTALL PROPOSED 6630 IN j/ i=[·I= =l=J=F·I I V EXISTING EQUIPMENT RACK (2) I/ TOTAL EXISTING TELCO PANEL -----~ lf-L..LLL~ r::: @ ~. -~ ~[7 ~"---INSTALL PROPOSED 6648 IN /-V EXISTING EQUIPMENT RACK (2) //'---V TOTAL /-- / !I,// @ EXISTING ELECTRICAL --------¥-_, 1 PANEL ,;. v:- / 1====1 ,,___++-1---EXISTING EQUIPMENT CABINET /, __, v/ _ RBS 2206 EXISTING RBS 6201 / ' /r-. --=~==-. --.-. -/ CABINET ~ ~---I j . / '/ / /i EXISTING AIR ---~=---+--+--f :+----1'--c,,t----PROPOSED PBC 6200 BATTERY CONDITIONING UNITS ~// 1 // CABINET, (1) TOTAL ~/ ~~ _ _...J I i'✓ ~ l'--===1 7-, __ _ -PROPOSED POWER 6230, (1) TOTAL = @ ~ '-----_J ~=~=====;:;==ti=J / "~-EXISTING EQUIPMENT CABINET RBS EXISTING EQUIPMENT CABINET j !I ' :; ; ii :1 I ! i ::-EXISTING OFFICE SPACE -/ //// 7 /7////////////////////~ !H I PROPOSED EQUIPMENT PLAN (FIRST FLOOR) 0 6" 1' 2' Lmf®*4b h•¾¼i!frd SCALE: 1/2"=1 '-0" (22x34) (OR) 1/4"=1'-0" (11x17) / EXISTING HALLWAY _ / 2 i $ V//// I///////////.~/~,_/_·~,/~,·~··_'_,··_/_,/~·/-·~/·_·.~✓-/~··-·/~/~·/~/~/~· ~ MAX CAPACITY IN AMPHOUR 26 I/ r V' ~ EXISTING SMOKE DETECTOR, FIRE ---------hL/j..j V ~ r/ ,_ NUMBER OF BATTERIES INSTALLED 4 EXTINGUISHER, EYE WASH STATION I/ , / 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM f' ,,. , l '1\l'-.,. 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.saDN.com REVISIONS REV DATE DESCRIPTION 0 07108/2020 90%CD's 1 07/14/2020 100% CD's INITIALS EC EC ,/1''...,sf.U AH.CJ..t ---e..., ~, 00"""_.. ........ 1/)"~ ~ tf v · .. o.A1 . . ' . ~ . ~ AND ENVIRONMENTAL KIT V: D n===~--¥--:t----EXISTING CABLE LADDER o I/ : ~ ~ MAXIMUM NUMBER OF BATTERIES PER CABINET 20 -v;:-• /-.-/./_'_ //__,,,7 / Q i====i j~...----REMOVE (1) DUS 41 FROM EXISTING ~. '-IESTO T. POPOWYC ' •• I * ., v-27496 ., * ~ • REN twAL 4-30-19 • 9 /e--_ I j/V EQUIPMENT RACK ~ 1£ -: , • r J • vl TOTAL CAPACITY IN KWH IN CABINET #2 1.248 EXISTING CIENA CABINET ------¥a,/""~ i=1=1=' 1 ', / ~ TO REMAIN I/ ; ~ ! v i EXISTING TELCO PANEL -----1-,"1 V ~ TOTAL CAPACITY IN KWH ON SITE 12.048 TO REMAIN ~ !====ii j / ' ~ I/ I / ;:': EXISTING ELECTRICAL ---------1'--,,,..l // EXISTING 19" EQUIPMENT RACK TO REMAIN ! PANEL TO REMAIN ~ j a. / ' 1+---1-,L.j--EXISTING EQUIPMENT CABINET "' ·~,__~ I I ! / RBS 2206 TO REMAIN I EXISTING RBS 6201 : ; ----~~~-'1,. '1 I I,, /j . . / ,' /' / i § CABINET TO REMAIN ; ~ 0 EXISTING AIR ---~----+,+--! +---t'---/-71---EXISTING PBC 6500 BATTERY i CONDITIONING UNITS ~ ~ ! 1 j CABINET TO BE REMOVED ~ '/ ~--_, '----...J f-e-t-crl----EXISTING EQUIPMENT CABINET RBS § ~'-I ---"-===1 :I / 3206 TO REMAIN ~ / ' r / i ~ ~~ j i j c____~____J ~====~.bd j _J ~ EXISTING EQUIPMENT CABINET---~'----'l II I / 8 ~ Ii II I I / / EXISTING OFFICE SPACE 5 //'-7-----r-=~---~---~---~---~~/ @ I ///////////////////////////~ NORTH ~----------------------------------------------------,--:--:-:-:---=--~-t-------------...!..·'-' -'-l-----------------------,--------,---------,-----.----1 ~-E_x_1s_r_1N_G_B_A_T_T_E_R_Y_c_A_L_c_u_LA_r_1o_N_s _________________________________ :_c; __ ~E-· ..._3__,i_E_x_1_s_r_1N_G_E_o_u_1P_M_E_N __ T_P_LA_N_(F_1_R __ s_T_F_L_o_o_R_) _________________ _,_ __ ?_, -6~_1_~•-•M_3_' ..,_s(~~A~~E--:..;,;1;.;.~~...;:~...;:_·~;.,.;~,;~~~~!~~~;:...) ....,__1...11 -----------··-·-·------- t~ ~• ..) J' ,.,,.i,,/w..--- ' '),. •• •• <".>...""-.~, 8 ~ / z:.. " •••• --"'\,.,., ~ ~ ,(_ A'-•I\'"{ \l _·Jlff! ~ "IHER~",TT, SWERE PR~~;~~ ,c.'MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EXISTING & PROPOSED EQUIPMENT PLANS, & EXISTING BATTERY CALCULATIONS SHEET NUMBER A-3.3 ci w f- ai 5: a! 0.. ":. f-u ii' f-(/) (/) (/) w u ~ PROPOSED ANTENNA LAYOUT PROPOSED ANTENNA LAYOUl @ ~=p==p==p==r===r==r===r=="ii=r'Tj;=IF'i'==r===r===r===r===;===,===r===rr=r===='=F==r===p=i====i="""='=f===r====a ~ EXISTING BUILDING @ I I ' ' i ' I ' ' I I I ~ 11-+--,--+---+------t-------t-----t----t----t-----i1 I I ----- 1 -- I ' • Ee l -r --. / TOP OF EXISTING STRUCTURE , "\ ELEV. ±37'-6" AGL \. ..,, TOP OF PROPOSED T-MOBILE PANEL ANTENNAS l"h . . =I=:=-=--::....::=:~-~:=-_ --~ ELEV. 37'-6" AGL 't" 11' ~ , RAD CENTER OF PROPOSED AIR6449 -+--- -r""'!"!". -i~ )\ \ "" T-MOBILE PANEL ANTE~ 1 \ , --ELEV. 36'-0'~ \ "" RAD CENTER OF PROPOSED AIR32 ""------.!-MOBILE PANEL ANTENNAS/'"\ -ELEV. 35' -6" AGL \. './ . \ \ RAD CENTER OF PROPOSED APXVAARR18 ~ \__ T-MOBILE PANEL ANTENNAS I' r,. --ELEV. 34'-6" AGL 'v . TOP OF GRADE $ ELEV. 0'-0" AGL bile~ REV 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM SAC -DES 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07/08/2020 90% CD's 1 07/14/2020 100% CD's INITIALS EC EC i½B----------------------------------------------------------------------------------------------------------------------r-------r.::-;:::-;-;-;:---:;--;;;;;-::;;-;;;;""i;:;;::;-:;,r.;;;--,----a ffi o 2' 4' 8' SCALE: 1/8"=1'-0" (22x34) .----;-------i-------------i----t1 °' PROPOSED NORTH ELEVATION lw,,1"'*1.,""''"' (OR) 1/16"=1'-0" (11x17) 2 ~1----------------------------------------------------------------------------------------------------------------------'-------...a...-'--....;..---------'--7.-~---~---------~--tl 0 f- "' w s w "' :i: u ~ ~ z '§_ I- "' w :i: 0 w "' ::, g 0 (/) 15 "' 0 w "' ::, >-z <( u.i "' ::, i >-a, ~ ii' 0.. 0 "' Q. "' U) f-z w 2 ::, g z 0 ti ::, O'. f-U) z 8 LL 0 1-w U) U) 5: f-z Cl w z ;:<: z 0 u z 0 ~ "' ----- EXISTING ANTENNA LAYOUT \ @ .J__ f I I I • I I ----!!~---t------t------t------t----1'-------1t---t---,1 I I I EXISTING ANTENNA LAYOUT ~ EXISTING BUILDING @ ! ! , l I l ---' I . I ., } I -r--.!.,_ - / TOP OF EXISTING STRUCTURE r, ELEV. ±37'-6" AGL "-./ TOP OF EXISTING T-MOBILE PANEL ANTENNAS A ELEV. 37'-6" AGL 'y RAD CENTER OF EXISTING T-MOBILE PANEL ANTENNAS ,I"\ ELEV. 35'-6" AGL \. ./ . TOP OF GRADE Q ELEV. 0'-0" AGL '-j_/ . 5:l----------------------------------------------------------------------------------------------------------------------,------,;;--;:::-;-;-;:---;;-;;;;;::~;;;;-;,;;;;:;;;-;--,--; z o 2' 4• 8' SCALE: 1/8"=1'-0" (22x34) 1 ESTO T. POPOWYC -27496 REN WAL 4-30-19 "" IJi'l----1"" "I HER WERE >----~ PREPARED MY DIRECT o SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EXISTING & PROPOSED NORTH ELEVATIONS SHEET NUMBER A-4.0 ~ EXISTING NORTH ELEVATION b,,,®-w-*'"''j (OR) 1/16"=1'-0"(11x17) f-L-----------------------------------------------------------------------------------------------------------------------------------"""'--------------- ci w r-m I 0 Ct'. a. § 12 f-U) ~ U) w 0 ~ w ~ EXISTING BUILDING PROPOSED ANTENNA LAYOUT @ ----- TOP OF EXISTING STRUCTURE ELEV. ±37'-6" AGL TOP OF PROPOSED T-MOBILE PANEL ANTENNAS , ELEV. 37'-6" AGL ' RAD CENTER OF PROPOSED AIR6449 T-MOBILE PANEL ANTE~. \ , ELEV. 36'-0'~ \ ~ D CENTER OF PROPOSED AIR32 T-MOBILE PANEL ANTENNAS \ --ELEV. 35' -6" AGL L ENTER OF PROPOSED APXVAARR18 T-MOBILE PANEL ANTENNAS ---ELEV. 34'-6" AGL TOP OF GRADE $ ELEV. 0'-0" AGL " REV. 10509 VISTA SOR.~ENTO PK\IVY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07/08/2020 90% CD's 1 07/14/2020 100% CD's INITIALS EC EC "'1---------------------------------------------------------------------------------------------------------------------,-------r:::::;-;--;--;:::--:~;::;;-;;;;--;::;;;:;-;;,,:--r-""1 n: O 2' 4' 8' SCALE: 1/8"=1'-0" (22x34) --t-------t-----------+------11 ~ PROPOSED EAST ELEVATION 1wl'"''•"'-"' (OR) 1/16"=1'-0"(11x17) 2 c'il-----------------------------------.;_ ________________________________________________________________________________ ....... ______ __,._.;_.;_ ____ .,;__.;__..___"11t-~---~--------~-- 2 (/) w '.5 w Ct'. I 0 ~ i f-z ~ f- 0'. w :r: t5 w Ct'. ::, § 0 (/) i5 Ct'. 0 w (/) ::, >-z <( ui Ct'. ::, i fu ~ w if ~ ~ [::' z w :,; ::, 8 0 a ~ Ct'. ti; z 8 LL 0 f-w U) U) j: f-z 0 w z ~ 8 z 0 ~ EXISTING ANTENNA LAYOUT ~ EXISTING BUILDING @ .-------TOP OF EXISTING STRUCTURE ELEV. ±37'-6" AGL TOP OF EXISTING T-MOBILE PANEL ANTENNAS ELEV. 37'-6" AGL RAD CENTER OF EXISTING T-MOBILE PANEL ANTENNAS ELEV. 35'-6" AGL TOP OF GRADE $ ELEV. 0'-0" AGL ~ ~•--------------------------------------------------------------------------------------------------------------------,,-:---::---:---:-:--r;:;::-;;-;-;:::--:;;;;;;-:;;;-;;;;-;::y;;;~,T-1 ~ 1t O 2' 4' 8' SCALE: 1/8"=1'-0" (22x34) 1 ' ,.,...,.._ •••• f/11-~~ 4, ~ • • • • <... c,;,. ~ TO T. POPOWYC 7496 4-30-19 • • • • • ·* • • WERE PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EXISTING & PROPOSED EAST ELEVATIONS SHEET NUMBER A-4.1 ~ EXISTING EAST ELEVATION ',.,,,,.i"*""• &1¥,1 (ORJ 1116"=1'-0" (11x17J ,_._ __________________________________________ ....,...., ____________________________________________________________________________ 'I ______________ _ ci w I-m I 0 " (l_ :>; 1-'2 a:: ~ £2 "' w 0 ~ w / ' TOP OF EXISTING STRUCTURE \;_ _I ELEV. ±37'-6" AGL ,-1---. TOP OF PROPOSED T-MOB!LE PANEL ANTENNAS "-1..1 ELEV. 37'-6" AGL RAD CENTER OF PROPOSED AIR6449 ~BILE PANEL ANTENNAS -. 36'-0" AGL / / RAD CENTER OF PROPOSED AIR32 / / i'°\ T-MOBILE PANEL ANTENNAS \ 1..1 -J ELEV. 35' -6" AGL I RAD CENTER OF PROPOSED APXVAA__:::; $ T-MOBILE PANEL ANTENNAS ---ELEV. 34'-6" AGL $ TOP OF GRADE ~ ELEV. 0'-0" AGL PROPOSED ANTENNA LAYOUT - @ ~ ,~ I -\, -""'i -I i .. / -- I ' 'I I I I I ----------------- ~ EXISTING BUILDING i n ' ' 1 n . i I I I I ' i (>''>/f,-,•,·,·,:. '/////-/-'_, :(/,<;~/;,;;,~;;;,;;;;::::? ,>~'/½/,:/.·, .·'//////1/-/ 'i•¾J/<"//-; ,;,1/.;,;,;'1;,:;::x 1}0df;{:;t,;:}~'.,, /.~;,;;~;;£:?:~:ii~* 0 /,;%%,:.:,~',//////// 1/, './'//-'////, . ,'/// :-· /, /·' ,,,,..>:! /·'·"' /, ,, ;,; / "'j;// //-' l?)rt;~~~ff~*:% :~~;~/-~:-<-<:?.-/~:/ '. . <'?~ ·:;ft:'.'.'.<·,, 1'./:: 1/,'/ // //,j/,"/ // /' ,. :·/ /'., ·/½ %0(:%,f 1>:;1/;;;;:~ ~ Q;;{;P ;f ,· '.;:?;;;:•//// ~(////,/ /.,. ///(/,-, '///fr,'./ -·>>//./,/,'////•.·,.;-'/,;./,./:> /-_,-·;,//;->/, . -< ,:-;://, ------'---. " -. --- ◄-► 1///;'.;'~/;'{,;. ,<:,>;:-<-:;:,;;,;~ /'/! _':·'/¼·'./'':%'' -1{?}?? ·&/t;;:;;,-;8 . •// ·;; //f:'/2 /:(///,/i/~ '/////<;;: ////~ /;/·>/// //. 7' ,;;% ,, ¼1/ •✓:,;;~//// /// ,;:,// '. /; / .·' . , obile~ REV. 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07/08/2020 90% CD's 1 07114/2020 100% CD's INITIALS EC EC ir----------------------------------------------------------------------------------------------------------------.-------~----------~--1 g: PROPOSED SOUTH ELEVATION O 2' 4' 8' SCALE: 118"=1'-0"(22x34) R---+----+---------1---11 gr-------------------------------------------------------------------~--------------------------------L=1,a=··='""'="=1."="="="·:_d__,l_..:'.:(O::R::.)__:,1'...'./1:::_6'_:'=.:,_1'::-0:_"~(1..'..1x~1:.'..7!....)_JL2-I I-11-~---~----------L----I "' w ~ w " I 0 I '< I ,- z 'f ,- " w :,: ti w a:: ::, 8 J 0 "' 15 6 w "' ::, EXISTING ANTENNA LAYOUT @ ~ EXISTING BUILDING ,":\ TOP OF EXISTING STRUCTURE \.._,/ ELEV. ±37'-6" AGL ~ 1 n ri _,A~cTfO;=,P-fO';,F~E'iXilS;;';T:;',IN:..::G:....:T:....:-Mc:.;.O=.:B::..:l=LE::.:P:...:A_::.N.:..=E=L-'-A::..:N_:..:TE:::N.:.cN=-A=S----:;;:;;a,~===r==;====r==;===""""ii"=="r===r=f.'=; =""'\==r===;F="';=====;==e:p===;====;;=====;F===;==~;Fj =1,i +i =:i-!= -=":;====r==l===;;===;====r===I 'y' ELEV. 37'-6" AGL ./" I T. POPOWY 7496 4-30-1 o::;, "' = "' = ~ <{ RAD CENTER OF EXISTING T-MOBILE ,--;(-#~\--l---f---------1----1-------l---~ _em: t--+:----1---+----+--+----+----I----II ,-, PANEL ANTEN:..:NAc...:;S::...___ -l !,1,'; J ~--!I"" w " ::, ~ i;, ~ w a' (l_ 0 " (l_ "' "' ,-z w :;; ::, 8 0 z 0 t ::, a:: I-"' z 8 u_ 0 1-w "' "' I 1-z 0 w z ~ z 8 ~ ~ '--./ ELEV. 35'-6" AGL • ' ~---+++---1-----1-------11 $ TOP OF GRADE . ~ ELEV. 0'-0" AGL ----------------- " ~t-------------------------------------------------------------------------------------------------------------------,---------,----------,,-,--,-,--r----1 ~ EXISTING SOUTH ELEVATION O 2' 4' 8' SCALE: 118"=1'-0" (22x34) ,-&-"'t''''·"-'"'""' (OR) 1116"=1'-0" (11x17) 1 ----------------------------------------------------------.L....:::.;;;;;:=:....J....,\:;~~~~..J.....-1 "I HER PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" l 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EXISTING & PROPOSED SOUTH ELEVATIONS SHEET NUMBER A-4.2 :- LJ 0 ci w I-- CD 5: 0 Cl'. 0. :':; 1--u °' ~ ~ U) w u ~ PROPOSED ANTENNA LAYOUT @ ~ EXISTING BUILDING PROPOSED ANTENNA LAYOUT @ ----- I~ I \--=i====tn ill~4 -=-l==f===f==+===1===+=+=1====1===r===+===+=t===i====t===r===r=1===t===t===t=====t=t=1 \ ' , -- TOP OF EXISTING STRUCTURE ELEV. ±37'-6" AGL TOP OF PROPOSED T-MOBILE PANEL ANTENNAS ELEV. 37'-6" AGL RAD CENTER OF PROPOSED AIR6449 T-MOBILE PANEL ANTE~ \ , ELEV. 36'-0'~ ------=--\ ~ D CENTER OF PROPOSED AIR32 T-MOBILE PANEL ANTENNAS ELEV. 35'-6" AGL l===l===+==l==4===!===!==lr=,,,,__ ~ RAD CENTER OF PROPOSED APXVAARR18 T-MOBILE PANEL ANTENNAS ELEV. 34'-6" AGL I I I I -J_...---- TOP OF GRADE ELEV. 0'-0" AGL ~ 1---------------------------------------------------------------------------------------------------------------------T-:---:::--:;----::-77,::;;;i=-1~:V::;:;;'iY.w,ui:i'-r-1 :t I o 2' 4• 8' SCALE: 1/8"=1'-0" (22x34) g; PROPOSED WEST ELEVATION 1--w..-f"'"l-wiE··••l (OR) 1/16"=1'-0"(11x17) 2 51---------------------------------------------------------------------------------------------------------....I..------.L-.:.......:..... ___ ___; _ ___;_.....___"1 12 U) w s w Cl'. I u i !:.t I 1--z :i I- D'. w 5 w O'. ::, U) 0 ~ u U) 0 O'. 0 w U) ::, >-z <{ u.i O'. ::, i i;, 1;: ~ °' 6 O'. 0. ~ U) 1--z w "' ::, 8 0 z 0 t3 ::, O'. ~ z 8 u. 0 t;; U) U) 5: 1--z 0 w z ~ u z 0 ~ "' EXISTING ANTENNA LAYOUT @ . • I ·" \. ~11-'c__---+----+----+----+---+---+-------ll I I EXISTING ANTENNA LAYOUT ~ EXISTING BUILDING @ .------ I I I t-_-,.. -r-- ◄ -- I TOP OF EXISTING STRUCTURE , I"\ / ELEV. ±37'-6" AGL \. J.J --TOP OF EXISTING T-MOBILE PANEL ANTENNAS A • I ~ ELEV. 37'-6" AGL 'f" - I RAD CENTER OF EXISTING T-MOBILE ,_ ) PANEL ANTENNAS, I"\ . -ELEV. 35'-6" AGL '-I.I ---------------TOP OF GRADE A ELEV. 0'-0" AGL 'f" 10509 VISTA SORRENTO PKVVY #206 SAN DIEGO. CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS REV. DATE DESCRIPTION INITIALS 0 07/08/2020 90% CD's 1 07/14/2020 100% CD's ESTO T POPOWYC -27496 REN WAL 4-30-19 WERE PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L 700-l 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EXISTING & PROPOSED WEST ELEVATIONS SHEET NUMBER A-4.3 EC EC i-u !5 1 ---------------------------------------------------------------------------------------------------------------------T-:---:::--:;---7.77,::;;;i=-1~:V::;:;;7Y.w,ui:i'_1_1 2 11-o 2' 4' 8' SCALE: 1/8"=1'-0" (22x34) ~L,E_x __ ,s_T_1_N_G_W_E_s_T_E_L_E_v_A_T_1_o_N ________________________________________________________________________________ 1,_ .. t_"·_-.,_,",_'"..,d ....... (o_R_J _1_11_6' .. '=1 .. '-0_"_(1 ... 1x_11_) __ 1_ ,.,, ____________ ., ci w ;- oi 'i: 0 O'. o,_ ~ ti ii' ;- if) if) if) w u ~ w if) O'. w ii' i 2 if) w ; w 0: I u ~ ;;; I ;- ~ ;- 0'. w I 15 w "' :::, if) 0 MANUFACTURER: MODEL: MECHANICAL CLAMP PROFILES: SUPPORT ARMS: FASTENERS: MOUNTING PIPE: ERICSSON SXK 125 0247/1 SINGLE RRU WALL SUPPORT KIT ALUMINUM, NATURE ANODIZED ALUMINUM, NATURE ANODIZED ACID PROOF STAINLESS STEEL 1"-2-3/8", ORDER SEPARATELY MOUNT TO WALL OR UNISTRUT UNISTRUT/WALL MOUNTED RADIO MANUFACTURER: MODEL: PIPE SIZE: CLAMP THICKNESS: THREADED ROD SIZE: VALMONT ACP08K, ACP1 OK, SCP08K, SCP1 OK, DCP12K, DCP18K PIPE-TO-PIPE CLAMP SET 1-1/2" -3-1/2", 1-1/2" -5" 1/4", 1/2" 1/2" X 8", 1/2" X 10", 5/8" X 12", 5/8" X 18" -USED FOR ATTACHING SIMILAR SIZED PIPES IN PARALLEL ORIENTATION -ALL HARDWARE INCLUDED -HOT DIPPED GALVANIZED -KIT INCLUDES (2) CLAMPS AXONOMETRIC VIEW REMOTE RADIO UNIT PLAN VIEW l(@). FRONT VIEW 1-1/2"=1'-0" (22x34 3/4"=1'-0" (11x17) I I ~ I SIDE VIEW 9 LL IGI H ,1<--E--,r ,,,___ ___ A ~---.r PLAN VIEW POLE MOUNTING HARDWARE MAY BE REMOVED FOR DIRECT MOUNTING B g. (.79") LOWER CLAMP SIDE VIEW I BOLT TORQUE: MA=40Nm I c8 (1.58") UPPER CLAMP SIDE VIEW A B C D. E F(O") G H 6.85" 2.68" 3.47" 2-3/8"-4-1/2" OD. AIR ANTENNA MOUNTING BRACKET MANUFACTURER: MODEL: MECHANICAL NET WEIGHT: DIMENSION (LxWxD): COLOR: MOUNTING: HARDWARE MATERIAL: ERICSSON RADI04449 74 LBS 14.95"X13.98"X9.25" WHITE STANDARD MOUNTING BRACKET HOT DIP GALVANIZED 4.33" 5.04" V: I !i I ir ,. :1 ,,. ,I 11111 117Tc7illli.llll 1, " 4.96" ±30° 3"=1'-0" (22x34) 1-1/2"=1'-0" (11x17 ~ 'ti ti~ RADIO MOUNTING PLAN VIEW 13.98" FRONT VIEW KIT (INCLUDED W/ RADIO) @ 9.25" SIDE VIEW 6 MANUFACTURER: MODEL: FREQUENCY RANGE: HORIZONTAL BEAMWIDTH: VERTICAL BEAMWIDTH: BEAM TILT: VSWR, RETURN LOSS: INPUT POWER PER PORT: POLARIZATION: IMPEDANCE: ANTENNA TYPE: BAND: MECHANICAL LIGHTNING PROTECTION: RADOME MATERIAL: RF CONNECTOR INTERFACE: RF CONNECTOR LOCATION: RF CONNECTOR QUANTITY: WIND LOADING MAX.: WIND SPEED MAX.: DIMENSIONS (DxLxW): NET WEIGHT: MOUNTING HARDWARE: RFS APXVAARR18_ 43-U-NA20 LOW BAND 617-746 MHz HIGH BAND 1695-220 MHZ 56.4", 56.7°, 58.6°, 58.7°, 63.1°, 63.3°, 64.3°, 64.8°, 66.1°, 66.5° 5.2°, 5.5°, 5.6°, 6°, 12.9°, 13°, 14.2' 2° -12° <1.5:1 250 WATTS DUAL ±45' 500HM CROSS POLARIZED QUAD BAND DC GROUND FIBERGLASS, UV RESISTANT 4.X-10 FEMALE BOTTOM 8 326 N @ 240KM/H 150 MPH 8.5"x72"x24" 106 LBS APM40-5E APXVAARR18 43-U-A20 MANUFACTURER: MODEL: FREQUENCY RANGE: BROADCAST BEAMS (TYP,): HORIZONTAL BEAMWIDTH: VERTICAL BEAMWIDTH: DOWNTILT: FRONT-TO-BACK RATIO: TRAFFIC BEAMS (TYP.): HORIZONTAL BEAMWIDTH: VERTICAL BEAMWIDTH: HORIZONTAL TILT: VERTICAL TILT: MECHANICAL LIGHTNING PROTECTION: RADOME MATERIAL: RF CONNECTOR INTERFACE: RF CONNECTOR LOCATION: RF CONNECTOR QUANTITY: WIND LOADING MAX.: DIMENSIONS (HXWXD): NET WEIGHT: ERICSSON AIR6449 841 E 2575-2635 MHz B42 3400-3600 MHZ 841 2496-2690 MHZ 65±5'165±5' 120±2' 10±1° I 30±3' 130±3° -8-8' 25DB 12' 122° 112· 9.5° 110° I 9.5" o· I 55' I 0° 3'13'118' DC GROUND FIBERGLASS, UV RESISTANT 4.X-10 FEMALE BOTTOM 8 753N 33.1"X20.6"X8.3" 96 LBS ANTENNA MOUNTING KIT APM40-5E (INCLUDED WI ANTENNA) @ co BOTTOM VIEW FRONT VIEW ;<----20.6" ---,f FRONT VIEW ,---------.----y PLAN VIEW M ex:, SIDE VIEW 1/2"=1'-0" (22x34) 1/4"=1'-0" (11x17) SIDE VIEW "' r-- 3 POLE MOUNTING HARDWARE MAY BE REMOVED FOR DIRECT MOUNTING @ d•-----------------------------------,--::-::--:--:--:::-=:----::-,-:---r----+----------------------------------T"".;-:;--:-:--:-:;-;:::::-'.::-::--.--+----------------------------------,-;;=~-;;;;=-;;----r--t ~ ..-2"=1'-0" (22x34) 1"=1'-0" (22x34) 1"=1'-0" (22x34) "' PIPE TO PIPE CLAMP 1"=1'-0" (11x17) 8 RADIO 4449 1/2"=1'-0" (11x17) 5 AIR 6449 ANTENNA 1/2"=1'-0" (11x17) ~ I----------------------------------....L----''---,:__--1-_--+-----------------------------------'------'---'--'---+-r---_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_----,--------------'--------~-""1 => r 7 , ----7 ANTENNA MOUNTING KIT 2 >-1 I MANUFACTURER: ERICSSON , MANUFACTURER: ERICSSON W ~ I I MODEL: RADIO 4415 11 MODEL: AIR 32, DUALBAND(/B66A/B2A) ~ w I I BAND2(1850-1910/1930-1990) ACTIVEFREQUENCYBAND g:; POLE MOUNTING~ I f 7" NOMINALVOLTAGE: -48VDC@25A BAND4(1710-1755/2110-2155): SUBSETOFBAND66A(AWS1+3) ~ HARDWARE MAY I I --ANTENNA OPERATING TEMPERATURE: -40'C TO +55'C BAND 66A (1710-1780/2110-2180):ACTIVE FREQUENCY BAND in BE REMOVED FOR ,---1, I NET WEIGHT: 20.0 KG/ 44.0LBS RADIO MOUNTING PA OUTPUT POWER: 2 X (4 X 30)W >-S-16_" ____ R T 1 ~, 7 DIMENSION(LxWxD): 14.96"X13.19"X5.39" KIT(INCLUDEDW/ DOWNLINKEIRP: 4X62.5dBmi ~ DI EC MOUNTING I r:=;:::r::::;=1 0 0 MOUNTING: POLE, WALL MOUNT RADIO) INST BANDWIDTH: B2 40 MHz (W,L) ~ L -1 cJ aO COOLING: CONVECTION (OPTIONAL W B2: 20 MHz (G) o_ I I ° FAN TRAY-FORCED AIR) ~ B66A: 70MHz (W,L) ~ I O ~ PLAN VIEW CAPACITY: 6 GSM (B2 ONLY) o,_ L': :'.J o o I j ~ ,,,______ 0 o I I O 6 WCDMA PER ACTIVE FREQ. BAND ~ ~--.-----"<-, 2 X 20MHz L TE PER BAND z I I w MULTI-RAT CAPABILITY: WCDMA & GSM ON BOTH PAs (82) 3 ,;_ I I f--5.4" 1 ,I'----13.2" ---,r WCDMA&LTEONBOTHPAs(B2&B4) 8 ~ I I I -GSM&LTE(B2) ~ ------, ~ OPTICALCPRI: 2X10GbpsPERACTIVEFREQ.BAND o I DC POWER: -48 VDC 3-WIRE OR 2-WIRE ~ I I ---,1v--,-0 AC POWER (OPTIONAL): PSU-AC 08 fc I I I I I OPERATING TEMP. RANGE: -40 TO +55 'C g/ l__ ) I I I SOLARRADIATION: ~1,120Wlm' 8 ', _,,,.,,,. I I I RELATIVE HUMIDITY: 5 TO 100% t', --____ --ANTENNA MOUNTING I I I m ABSOLUTE HUMIDITY: 0.26 TO 409/m' t;j BRACKET I :;:!: MAX. TEMP. CHANGE: 1.0'C/min "' I ELECTRICAL TILT: 2'-12°(866A), 2' -12' (82) ~ I BORE-SIGHT ANTENNA GAIN: 18dBi (866A), 17.5 dBi (82) ~ I O §l NOMINAL BEAM-WIDTH AZ: 65' (B66A), 63° (82) 0 NOMINAL BEAM-WIDTH ELEV: 6° (B66A), 6° (B2) ~ ANTENNA MOUNTING _ ____,.,_, : MECHANICAL 0~ PIPE I WEIGHT: I I ~~ u I I WIND LOAD: i5 L_J L __ 7.J7 r ~ BOLT TORQUE: MA=40Nm L J 2 BOLT TENSION: 15.9kN SIDE VIEW FRONT VIEW 132.2 LBS 56.6"x12.9"x8.7" 143.878 LBF / 67.4427 LBF / 148.374 LBF -12.9" ~ - " ' • ' • [] <q CD "' ' ' ' 0 '-="'-. _, 8.7" SIDE VIEW BACK VIEW FRONT VIEW ~1-----------------------------------,....,...~-,-,-=.,.,---,-.,.,..--l------------------------------------r--------,---+-----------------------------------,;;;-:;-;--;:;;-;;:;;;::;;-;;--ir---l z 1-12"=1 '-0" (22x34) 1 "=1 '-0" (22x34) ~ .._A_PM_4o_-_sE_A_NT_E_N_N_A_M_o_u_N_T_IN_G_B_R_A_C_K_E_T _________ 3_I4_ .. =1_._0 __ .. (_11_x1_7l ...... 7......,._RA_D_IO_44_1_s _________________ _... __ N_T_s _____ 4_A_I_R3_2_K_R_D_9_01_1_4_6-_1 _B_B_6_6A_I_B2A_A_N __ T_E_N_N_A _____ ......, ___ 1I_2 .. =_1• __ 0, __ • (1_1x_17_l _1_ ----------·------------------· - ff.I .. .1 !Ill l!il !II obile~ REV. 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 2J-;_C )/= DES!C:\\j ,::.1~~i')UF, )!,JC. 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07108/2020 90% CD's 1 07/14/2020 100% CD's T. POPOWYC -27496 REN WAL 4-30-19 "I HER WERE PREPARED B R MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" l 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EQUIPMENT DETAILS & SPECIFICATIONS SHEET NUMBER A-5.0 INITIALS EC EC PROPOSED CABINET ---------~--i ½" 0 HILT! KWIK TZ STAINLESS STEEL ----~ ANCHOR W/ 2" MIN. EMBEDMENT (SPECIAL INSPECTION REQ.) ICC ESR-1917 EXISTING FINISH FLOOR ---------~ CABINET ANCHORAGE <J ;:j ' ~ <l <i L <i " ·> NTS "' <J L! " <i L. <i 2 MANUFACTURER: MODEL: 10 HOUR CAPACITY TO 1.80VPC @ 25'C (77F): 8 HOUR CAPACITY TO 1.75VPC @ 25'C (77F): 10 HOUR CAPACITY TO 1.80VPC @ 20'C (68F): FLOAT VOLTAGE: NOMINAL VOLTAGE: IMPEDANCE (1kHz): CONDUCTANCE: SHORT CIRCUIT CURRENT: MAXIMUM CHARGE CURRENT: WEIGHT: HEIGHT: WIDTH: DEPTH: TERMINAL: TERMINAL TORQUE: NORTHSTAR NSB 1 00FT RED 100Ah 100Ah 99Ah 2.29 +/-0.02 VOL TS/CELL 12V 3.9 1,298 S 3,500A NO LIMIT 72Lbs. (33Kg) 11.3 in. 4.2 in. 15.6 in. FEMALE M8x1 .25 8.0 Nm. (71 in-lbs) BATTERY (EXISTING) DEGASSING PORT 2 PLCS -----15.6" -----,r FLAME ARRESTOR PRESS FIT INTO VAL VE COVER 2 PLCS n ('") ._______,J 2"=1'-0" (22x34) 1"=1'-0" (11x17) MANUFACTURER: MODEL: EATON DURA-BLOK • MADE FROM 100% RECYCLED RUBBER • REFLECTIVE STRIP ON BOTH SIDES ALLOW FOR EASY PRODUCT VISIBILITY • NO ROOF PENETRATION REQUIRED • PRODUCT COMPOSITION IS NOT SHARP OR ABRASIVE; HELPING TO EXTEND THE ROOF LIFE • DAMPENS VIBRATION • NO NEED FOR SUPPLEMENTAL RUBBER PADS 7 DURA-BLOK™ NTS 3 f-=,....=.--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=;-------------'--------'---,-;::::==========================::;------~---~-----r-.-=-=-=-=--=--=-=-==--=--=--=--=--=--=-=-=-=-=-=-=-=~---------..L.-----'---7 ci w I-m :i: 0 Cl'. a_ ':; ~ ii:: ½ U) U) t'! ii' w U) Cl'. w Cl'. Cl'. 5 0 1- U) w s w Cl'. :i:: (_) I \;' :i:: 1-z <( :i:: I- C:: w :i:: ti w Cl'. ::, ~ ~ MANUFACTURER: MODEL: WEIGHT: HEIGHT: WIDTH: DEPTH: POWER FACTOR: BATTERY CAPACITY: TEMPERATURE RANGE: RECTIFIER NOISE LEVEL: 21.6" ERICSSON PBC 6200 2200Lbs. 72.44 in. 23.62 in. 23.62 in. >0.99 123.62"1 '-··--·-- I .· --... ·-C \ ---POWER UNIT 123.62"1 48V/140-760 Ah (BATTERY RACK CAPACITY, AGM BATTERIES) G >---<e+--EXISTIN BATTER IES NORMAL OPERATION: +5 TO 50'C <50 dB(A) AT 25 'C . ....____ - = ~ cri ~ ~ "' 0 ,.__ '° 112" 0 HILT! KWIKTZ STAINLESS STEEL ANCHOR W/2"MIN. EMBEDMENT (SPECIAL INSPECTION REQ.) ~t--------; ICC ESR-1917 '} A - SECTION A-A FRONT VIEW SIDE VIEW '} A MANUFACTURER: MODEL: DIMENSIONS: WEIGHT: ERICSSON BB 6648 19.0"X1 .2"X12.8" 14.33 LBS • LTE, WCDMA & GSM CAPACITY AND MIXED MODE CAPABILITY • 15 SFP/SFP+ FOR CPRI INTER-CONNECT TO RADIO UNITS REDUCING THE NEED FOR BASEBAND R503 • 2 OPTICAL 1l1DGBPS SFP/SFP+ PORTS • 2 ELECTRICAL 1GBPS RJ45 PORTS • DUAL 48V POWER FEEDING • SELF-CONTAINED ENVIRONMENTAL CONTROL • FIELD REPLACEABLE FAN UNIT .--··-------------------19.0" --------------------r'- T NOTE: 1. RUN #2 AWG BCW GROUND CONDUCTOR ALONG CABLE TRAY AND GROUND AT BOTH ENDS. 2. CABLE TRAYS SHALL BE FREE OF SHARP OBJECTS AND BURRS WHICH COULD INJURE CABLES. COVERS SHALL BE FASTENED USING HOLD DOWN CLIPS. SHEET METAL SCREWS ARE NOT ACCEPTABLE. CABLE TRAY WITH COVER, 9" RUNGS, 4" LOADING DEPTH. SUPPORT CABLES WITH TIE-WRAPS OR STAINLESS STEEL CLAMP EVERY 6 FT. PROVIDE SOLID BOTTOM TRAY AT GRADE PER PLAN ,--HOLD DOWN CLAMP FASTENED TO DURA-BLOK 1----DURA-BLOK OR APPROVED EQUAL @ '-'ll-----------------------------------r--,-::-..,.,-=-:-::-::--c:-c,---r---+----------------------------------r-------,,......-+-----------------------------------r-::::---,-;---::-::-=--::-:-:--,---1 "' 1 "=1 '-0" (22x34) 2"=1 '-0" (22x34) ~ PBC6200 1/2"=1'-0"(11x17) 8 BB6648 NTS 5 CABLETRAY 1"=1'-0"(11x17) 2 wll----------------------------------__._ ______ _.__--+----------------------------------'---------'"---+-----------------------------------'--------'-----tl <fJ ::, ~ <( ui Cl'. ::, ~ fu ~ w ii:: a_ 0 g: ~ ~ z w :;; ::, 8 0 t\ ti ::, c:: ½ z 8 "-0 tii U) "' :i: 1-z 0 w z ~ B (_) z 0 ~ c:: MANUFACTURER: MODEL: 8 HOUR CAPACITY TO 1.75VPC@ 20'C (68F): FLOAT VOLTAGE: NOMINAL VOLTAGE: IMPEDANCE (1 kHz): CONDUCTANCE: SHORT CIRCUIT CURRENT: MAXIMUM CHARGE CURRENT: WEIGHT: HEIGHT: WIDTH: DEPTH: TERMINAL: BATTERY CORP BC-12V26FT 26Ah 12V 12V 3.7 1,288 S 3,500A NO LIMIT 23Lbs. 10.2 in. 3.80in. 15 in. MB-F -----15" -----;( 1¼11 I I I ·n I 3.80" t N 0 ~ J MANUFACTURER: MODEL: DIMENSIONS: WEIGHT: ERICSSON BB 6630 19.0"X1 .2"X12.8" 14.33 LBS • LTE, WCDMA & GSM CAPACITY AND MIXED MODE CAPABILITY • 15 SFPISFP+ FOR CPRI INTER-CONNECT TO RADIO UNITS REDUCING THE NEED FOR BASEBAND R503 • 2 OPTICAL 1/10GBPS SFP/SFP+ PORTS • 2 ELECTRICAL 1GBPS RJ45 PORTS • DUAL 48V POWER FEEDING • SELF-CONTAINED ENVIRONMENTAL CONTROL • FIELD REPLACEABLE FAN UNIT ,. 19.0" T N ~ l C C " D " D C7 C D D D D CJ I , ' I ! ! ' I ' I I I I I I ! I I i ' I L..c...J w,_r;_r-c-1 ~ ::-;-H ~,_ ~ ::-: r ~ ~ rH :H :H r' H • P::H _r H H H ;:,-;= ;: ' -)->--;:: '}--'r-)-( ,..;->-)-r t' r-',...f\ >-\... ;-' -)-, H H~ ~i □iC7!01 1 □1 L]L]L] i )-~~H::~ n n w w J-'.._,_/ .. \_i-' ' L,-r' L,_-J )-)-}-<}-}-,' )-'. ,-__,_ _)---{__;--\ _J-'\____r',._;--.,_;-\_r',..../' /-',. /-\ ~ " WAVE GUIDE--, ENTRY PORT ~--18 GA. GALV. LID STAMPED WI DRAINAGE RIDGE ----DOUBLE HINGED WI WATER SEAL & HOLD CHAIN ~--18 GA. G.L ROOF HATCH 6" BASE FLANGE (MITER ALL CORNER JOINTS WI CON. SOLDERDED SEAM SANDED SMOOTH) '---SECURE WI FLAT HEAD SCREWS FLUSH WI SURFACE '---SET ROOF HATCH IN BED OF MASTIC it1-----------------------------------.---------.---+----------------------------------..--------,r--+-----------------------------------,--------.---t z 2"=1'-0" (22x34) 8 BB 6630 NTS 4 ENTRY PORT HOOD NTS 1 obile~ 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM if)J}:i?~,. fl,;J.iJ, '\...J WIRELESS 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS 11-"=RE-V. ,-----D,-TE--,----DE-SC_R_IPT-ION----,-1-NIT-IAL-J!S 0 07/08/2020 1 07/14/2020 90% CD's 100% CD's T. POPOWYC 7496 L 4-30-19 EC EC • • ·* • • "" '" = "' "" "" ---llt; "I HER WERE 0 PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EQUIPMENT DETAILS & SPECIFICATIONS SHEET NUMBER A-5.1 ~ BATTERY (EXISTING) 1 .. =1,_0,. (11 x17l ,_ ... _______________________________________________ .,,__ ..... _..,. ___________ ..... ___________________________________________ .... ____________ ...., ___ ...., __________________________ . "'-----------------"' 0 w ,_ "' :c :i) [1- ".:; t, ii' t;; '!! "' w u ~ w "' "' w ii' 5 NOT USED 9 NOT USED 6 NOT USED 3 REV 10509 VISTA SORRENTO PKWY #2D6 SAN DIEGO, CA 92121 T-MOBiLE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sac:w.com REVISIONS DATE DESCRIPTION 0 07/08/2020 90% CD's 1 07/14/2020 100% CD's INITIALS EC EC ~ -_,,~-----"' ,r I ff .I"' -• ..--_.,.._, ~ fl'' 5'E.U AKC '~ ~ ,, 0«,,.~ --•••••• f./11-~ ~ i ,t ~ -' •• 0~ i ' v. · ... /' ~ ~ . . '~ fC t ESTO T. POPOWYC I .. ~ ~ * ! C-27496 : * t5 4 REN _WAL 4-30-19 • I--N-O_T_U_S_E_D---------------------,--8-+--NO_T_U_S_E_D ___________________ --,--5-;---NO_T_U_S_E_D ___________________ --,--2----~ ~ :~~rr , '·. ~ ~:+--2--. - ~ -... '</ /'1::--...... ,<" ~~,, ~ ;' MANUFACTURER: ERICSSON ~ ,nc:: ~ f\.. \ h ,fl"0 "" ~ MODEL: POWER 6230 "I HE~eiAi T WERE g :J,! DIMENSIONS (HX\lvXD) TBD PREPARE~ _ n MY DIRECT ~ WEIGHT: TBD SUPERVISION AND THAT I AM DULY REGISTERED 2 ARCHITECT UNDER THE LAWS OF THE STATE OF ii; • FLEXIBLE DC POWER EXPANSION AS NEEDED UP TO 28KW CALIFORNIA" >-(N+1, 3.5KW X 9 RECTIFIERS ~ • REQUIRES ADDITIONAL 19" RACK SPACE FOR BATTERIES w • SUPPORT FOR SPD BOXES FOR REMOTE RADIOS ~ • SUPPORT FOR 3PP EQUIPMENT "' [1- "' "' ,_ z w "' ::, 0 0 0 is B ::, lY t;; z 0 u u.. 0 ,_ w "' "' :i: ,_ z 0 w z ;i= z 0 0 is ~ "' lY f21----------------------------------------.-----1---------------------------------------,---+---------------------------------,------,---. z ~ NOT USED 7 NOT USED 4 NTS 1 POWER 6230 ,_.,_ ________ ....,...., __________________ ...., ______________ ....1, __ ...1 ................... _ ... _______________ ...., _______________________________________ ...., ________ ...,. ________________________ _ L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EQUIPMENT DETAILS & SPECIFICATIONS SHEET NUMBER A-5.2 ci I'=' iii I 0 n: 0.. >:; to QC ti; ;Q U) w u ~ w U) n: w QC n: c3 I=' U) w ~ w n: :r: (_) I ~ f-z <( :r: f-n: w :r: ti w Ct'. ::, g u U) i5 Ct'. 0 w U) ::, ~ u.i n: ::, i ;;, >-~ w QC 0.. ~ U) ~ z w "' ::, u g z 0 ;:: u ::, Ct'. f-~ 0 u "-0 f-w Cf) Cf) :r: f-z □ w z ;" z 8 z 0 PLAN L3x3x1/4" 2' LENGTH, TYP. OF 2 PER MOUNT SECTION 0:: (!) U) -~o~t:i o >-Cl ~ :.:: :;;~ ~ 5~ ~ 2 CJ I :~ I ~ I I I I I I I I I 1@1 I I I I I I I I I i----NEW P1000, TYP. OF 2 PER MOUNT I I I I I (@I .I<----------21-611 ----------., ~--PROPOSED T-MOBILE L 1900 RRU MOUNTED TO PROPOSED SLED ~ ~,---+--+----L3x3x1/4" 3' LENGTH, TYP. OF 2 PER MOUNT =· ---------1/2"0 A 307 M.B. b "';'l ~ -~ fl---'-------------~~__f--J-r------L3x3x1/4" 10" LENGTH, TYP. OF 2 PER MOUNT 1----+--+----L3x3x1/4" 2'-6" LENGTH, TYP. OF 2 PER MOUNT 11--o----+----4x4 PVC SLEEPER, TYP. OF 2 PER MOUNT Jc---------2' ---------.r PROPOSED ANTENNA FRP SKIRTS, TEXTURED & ---~ PAINTED TO MATCH EXISTING BUILDING, TYP. ALL SECTORS #8 TEK SCREWS @ 24"0.C. FOR FRP -----~ PANEL ATTACHMENT ~-----(2) PROPOSED U-BOL T ,,--(2) L2X2X1/4" ANGLES (VERTICAL) !!,,,t----(2) L2x2x1/4" ANGLES (HORIZONTAL) 3/8"0 A307 THRUBOLTS (TYP.) ------------;~~ii~:i!lCil5=i::_:~=-!~II-----"" (1) PROPOSED 2 STD. MOUNTING PIPE PROPOSED WIRE MESH FOR ------------ VENTILATION TO BE INSTALL TOP & BOTTOM (TYP. All FRP BOXES) H#-==-----11----PROPOSED VALMONT PIPE TO PIPE CLAMP EXISTING MOUNTING PIPE ATTACHED TO EXISTING --,L-,--c/"'---,,7'. --,,"'----,L--,L---,,-7'.-J BUILDING TO REMAIN / / ./ PLAN PROPOSED WIRE MESH FOR ---------.. VENTILATION TO BE INSTALL TOP /,• /' & BOTTOM (TYP. ALL FRP BOXES) .i,....:::a'"s::"----PER PLAN ____ __,, (2) L2X2X1/4" ANGLES (VERTICAL) AT ------+++1--'----'--~-+lt----l EACH SIDE (2) L2x2x1/4" ANGLES (HORIZONTAL) -----iit~~~-JifF";,~ifI:.:..:DL TOP&BOTTOM (2) 3/8" PROPOSED U-BOL T --------.J+-1-----,;----+tr-lt:~>:!ii A307 PROPOSED MOUNTING PIPE 2 STD. _____ __µl+'-~""-"---+-ll---+--- A53 GRADE B, 6' LONG ATTACHED TO EXISTING MOUNTING PIPE #8 TEK SCREWS@ -------------H+--c-~--:-+it--i--<Q) 24"0.C. FOR FRP PANEL ATTACHMENT PROPOSED ANTENNA FRP ----------+rt,-~--c--c-tit-7' SKIRT, TEXTURED & PAINTED TO MATCH EXISTING BUILDING, TYP. ALL SECTORS .o . I. i, I I . ! . 1· i , . I. . , .. ·1. . I I : -I - i • ; • I 1. , I I •· I . J I • ! • . i. . . I - / 0 / J---7'-.· EXISTING PARAPET EXISTING MOUNTING PIPE ATTACHED TO EXISTING BUILDING TO REMAIN (4) 1/2" 0 LAG SCREWS W/ 3" MIN. EMBEDMENT VERIFY IN FIELD i / ~1----------------------------------------,-0-2'-' -4,-' --8-.. ,-;;-sc;:-A;;L-;:E::-:1 1'-1,;,/2;;;:"=::;17'.•_o;:;;:"~(2;;;2x;:;:;:34")-r-+--------------------------------------L"---'"---'/~·· ""'.'T-;0~2; .. -;4;::-.. -'--;8;"11-~-S~C~A~LE[:==1~-1~/2~"~=1~·-~o~·-·(~22~x~34;4_)c=J1.:7 SECTION ~~R:A:D:l~O~M:O~U=N~T1:N~G~D~ET~A~l:L ____________________ ~;=,;=r~w=i,em=••=w~~~(~OR~l~31~4 .. =~1~,_0~ .. (~11~x1~7l~~-2~-A-N_T_E_N_N_A_M_o_u_N_T_IN_G_D_E_T_A_IL ___________________ ~i._ .. ,_r_,_ ... _.,,_.,,:1~~(o_R_J_3M_"=_1·_-0·_·(1_1x_11_J ___ 1_ ---------------------------------·-·-·--------- obile~ REV. 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07/08/2020 90%CD's 1 07 /1412020 100% CD's T. POPOWYC -27496 REN WAL 4-30-19 INITIALS EC EC = ''" cc, "' "° ---I<=<> WERE PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA' L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE STRUCTURAL DETAILS SHEET NUMBER S-1.0 ,_ L) 0 ci ~ CJ ~ 0.. ".., t, g: w w w LU 0 ~ LU w 0: LU ti' 5 12 w ~ LU er: I 0 ~ '< I I- ~ l-o: w I ti LU er: ::, w g #4 OR #6 AWG SOLID CU CONDUCTOR WITH GREEN, 600V, THWN-2 INSULATION (Q) (Q)(Q) (Q) (Q)(Q)(Q)(Q)(Q)(Q) (Q) (Q) (Q) (Q) (Q) (Q) (Q) (Q) (Q) (Q) © (Q) EXISTING GROUNDING BAR ON WALL, -~ FLOOR, OR ON ANTENNA TOWER TWO HOLE SPADE, TO BE USED TO --~ CONNECT TO GROUND BAR GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER 1. APPLY NO-OX TO LUG AND BAR CONTACT SURFACE. DO NOT COAT INLINE LUG. 2. IF STOLEN GROUND BARS ARE ENCOUNTERED, CONTACT T-MOBILE CM FOR REPLACEMENT THREADED ROD KIT. WIRE INSTALLATION TO ANTENNAS --~ RX2 COAX JUMPER (TYP.) CONNECTOR---- WEATHERPROOFING KIT (TYP) SEE NOTES ANTENNA CABLE TO RBS EQUIPMENT (TYP) TO EXISTING GROUND RING I ) SCALE N.T.S. CONNECTOR WEATHERPROOFING KIT (TYP) SEE NOTES GROUND KIT (TYP) L,__->--#2 AWG GALVANIZED STEEL ANTENNA GROUND BAR, WITHOUT INSULATORS. BONDED I DIRECTLY TO TOWER l ~-~ TO EXISTING GROUND RING ~-----------------------~--SCALE ~ GROUND CABLE CONNECTION 0 N.T.S. 8 7 wl------------------------.,__ __ _.__-i ~ ~ <( w er: ::, ~ 1n ~ w ti' 0.. 0 0: 0.. '2 ~ LU :,;; ::, 8 D z 0 ~ ::, 0: I-"' z 0 0 u_ 0 I-LU w w :E 1-z D LU z ~ z 0 u z 0 !:;: TYPE TA TYPE VB TYPEVN TYPE NC TYPE SS TYPE PT TYPE GT TYPEGY r.\ EXISTING ANTENNA GROUND BUS BAR NEAR ANTENNA MOUNTS WITH COAX \.V GROUND KIT. SEE DETAIL 6/G-1.0. r,;\ EXISTING #6 AWG GROUND FROM ANTENNA GROUND BUS BAR TO TIE INTO \V EXISTING GROUNDING SYSTEM (TYP OF (2) PLACES). SEE DETAIL 7/G-1.0. r,;\ PROPOSED #6 AWG GROUND FROM EQUIPMENT MOUNT TO ANTENNA GROUND \V BUS BAR. SEE DETAIL 5/G-1.0. r;---,, PROPOSED #6 AWG GROUND FROM ANTENNAS TO ANTENNA GROUND BUS BAR. 'v SEE DETAIL 6/G-1.0. r,;-,. PROPOSED #6 AWG GROUND FROM RADIOS TO ANTENNA GROUND BUS BAR. \V SEE DETAIL 6/G-1.0. (';\ EXISTING EQUIPMENT GROUND BUS BAR NEAR EQUIPMENT WITH COAX GROUND \!V KIT. SEE DETAIL 7/G-1.0. 0 #6 AWG GROUND BATTERY CABINET TO EQUIPMENT GROUND BUSS BAR. SEE DETAIL 7/G-1.0. fo\, EXISTING #6 AWG GROUND FROM EXISTING EQUIPMENT GROUND BUS BAR TO TIE \!V INTO EXISTING GROUNDING SYSTEM (TYP OF (2) PLACES). SEE DETAIL 7/G-1.0. GROUNDING KEY 00 00 00 00 00 00 00 00 00 00 --G-- COPPER GROUND ROD MECHANICAL CONNECTION CADWELD CONNECTION FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM TEST WELL GROUND BAR GROUNDING WIRE GROUNDING LEGEND SCALE N.T.S. SCALE N.T.S. 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 5 4 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS, FOLLOW ANTENNA AND BTS MANUFACTURES PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELDS AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. 4. 5. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT-MOBILE REPRESENTATIVE. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. CONTRACTOR TO ABIDE BY ALL T-MOBILE SAFETY STANDARDS DURING SITE CONSTRUCTION. 7. CONTRACTOR SHALL REFER TOT-MOBILE STANDARDS FOR GROUNDING CONNECTIONS & INSTALLATION METHODS. 8. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED T-MOBILE REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING. 9. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 10. GROUNDING ROD NOTES (WHERE APPLICABLE) 11. ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL UTILIZING THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST AND CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING LINE, GRAPHED OUT TO SHOW THE PLATEAU. 12. POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS ISOLATED. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS ISOLATED FROM THE A/C SYSTEM GRIDS AND EXISTING COMMUNICATIONS FACILITY. SCHEMATIC ANTENNA GROUNDING PLAN D D 0 5 i---...__ TYP. ( I \ ~ /, i7===n u . . I I / / / SCALE: 1/4"=1'-0" (22x34) (OR) 1/8"=1 '-0" (11x17) / 2 / / / / ~ TYPE W TYPE VS TYPE GR TYPE GL ~1----==~:...... ___ .:;:::::::;:::=. ____ ::'.:::'.::'.~~----r---==~=----l------------------------r---r--l-----------....1•~·i1 __________________________ -,-------,-------:-::::-:~::::-:-=-:::-:-:---ir--l 10509 VISTA SORRENTO PKV\IY #206 SAN DIEGO. CA 92121 T-MOBILE.COM 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS REV. DATE DESCRIPTION INITIALS 0 07/08/2020 90% CD's 1 07/14/2020 100% CD's ""I HER T. POPOWYC -27496 REN WAL 4-30-19 PREPARED MY DIRECT SUPERVISION AND THAT I AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF CALIFORNIA" L700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EC EC SCHEMATIC GROUNDING PLANS, NOTES & DETAILS SHEET NUMBER G-1.0 }- LJ c:, z SCALE SCALE o 6" 1' 2' SCALE: 1 /2"=1 '-0" (22x34) ~--E_xo_TH_E_R_M_1c_w_EL_D_c_o_N_N_E_cT_1_o_N_s ____ .....__N._T.s_ . ......,_e ___ G_E_N_E_RA_L_G_R_o_u_N_o_1N_G_N_o_TE_s ______ ..,_N_.T_.s_._3 __ s_c_H_E_M_A_T_lc_E_o_u_1P_M_E_N_T_G_Ro_u_N_D_1N_G_P_L_A_N ____________________ b,,_.,l_H1_,,,_'*_••l.......,_(o_R_)_1_M_"=-1'-0_"_(11_x1_7J __ 1_, ___________ _, ci ~ in :i: 0 "' IJ.. >-J t-o a' >-Cf) Cf) Cf) w 0 ~ w Cf) O" w a' O" c3 0 >- Cf) w !;;: J w "' :r: s2 ;1i !;;: I t--z '?. >-- "' w I 15 w "' ::::, 13 J 0 Cf) 15 "' 0 w Cf) ::::, ~ w O'. ::, !;;: z >-Cil >-"' ;': w a' ~ O'. Q. Ul (f) t--z w " ::::, 8 □ z 0 ti ::::, O'. ti z 0 u LL 0 t--w Cf) Cf) :i: t--z Cl w z ;"' z 0 u z 0 ~ ~ Power Subrack CONTRACTOR TO REFERENCE FINAL RFDS PRIOR TO CONSTRUCTION LTE 700 800 N600 ...... Radio 4449 • Radio 4415 PBC 6200 ALPHA AIR6449 B41 L2500 N2500 AIR32DB ' ' ' LTE l ' ' ' AWS [ ' ' ' ' ' ' LTE PCS GSM Ground Bar LTE 700 600 N800 Site Configuration 67D5997D8 Radio 4449 I BETA Radio 4415 P6230 AIR6449 B41 L2500 N2500 I and Battery Cabinet -- AIR32DB LTE LTE LTE 7DO PCS 600 AWS GSM NIOO Groun Bar --a g :o, Rack Radio 4449 I GAMMA Radio 4415 AIR6449 B41 L2500 N2500 I 19:0~ Rack BB aeeeao aaeeso 30 •1 ■■o■d ,,.,o w PSU 48 13 V-01:tage Bo oste-r AIR32DB LTE : . ' AWS : . ' ' . LTE PCS GSM RBS 3206 D D D D 0 11---- iE :::, ... D D I D D ----.o :::, ..,_ I :::, :::, u... ..,_ ~··Mobile· RE'✓. 10509 VISTA SORRENTO PK\1\/Y #206 SAN DIEGO, CA 92 121 T-MOBILE.COM WIRELESS SAC AE DESIGN GROUP , INC . 5015 SHOREHAM PLACE, SUITE 150 SAN DIEGO, CA 92122 www.sacw.com REVISIONS DATE DESCRIPTION 0 07108/2020 90%CD's 1 07114/2020 100% CD's RF DESI GN BY T-MO BILE FOR REFERENCE USE ONLY OCT 2 6 2~Z~ L 700-L 1900-ANCHOR FARADAY EXECUTIVE CTR SD06918A 2382 FARADAY AVENUE CARLSBAD, CA 92008 SHEET TITLE EQ UIPM ENT CO NFI GURATI ON SHEET NUMBER RF-1.0 DATE: INITIALS EC EC "L~===========:_ ______________________________________________________________________________________ P.sgcA~L~E=r~ 1 1] ;~E~QU~IP~M~E~N~T~C~O~N~F~IG~U~R~A~T~IO~N~---------------------------------------------------------------------N._1.s_. __ '------------