HomeMy WebLinkAboutCT 2019-0004; 330 CHINQUAPIN AVE; Preliminary Hydrology and Hydraulics Report; 2020-10-02-
-
--
..
--
• .. --
-----
-
-...
-
-
...
-..
... ~~--~~ ,.,....,..r-,.,
__ J..J
OCT o 5 2020
Cl:-\ ,j,-\.~ Y'.'_SBAD
P~-~->.::<:.<~: .=•;_''.:=::_.J
CT2019-0004/PUD 2019-0004/ CDP 2019-0012 /
DEV 2018-0087
330 Chinquapin Avenue
Carlsbad, CA
92008
Preliminary Hydrology and Hydraulics Report
c/o Mr. Cameron Crockett
Project Submittal Lead
Ultra-Unit Architectural Studio
1327 Loma Avenue
Long Beach, CA 90804
Prepared to the City of Carlsbad
for
Mr. Jeff Galizio
330 Chinquapin Avenue,
Carlsbad, CA 92008
Dec 20, 2018
Update October 14, 2019
Update July 22,2020
Update October 2,2020
Prepared By:
CJE
Cory Jones Engineering
1820 S. El Camino Real, Unit A205
Encinitas, CA 92024
Cory Jones, PE, QSD/P,
QISP ToR, ENV SP
This Drainage Report ("Report'?:
1. has been prepared by Cory Jones Engineering (CJE) for Mr. Jeff Galizio with the intended use of supporting
the City of Carlsbad grading permit application;
2. may only be used and relied on by the Mr. Jeff Galizio;
3. must not be copied to, used by, or relied on by any person other than the Mr. Jeff Galizio without the prior
written consent of CJE;
4. may only be used for the purpose of evaluating site drainage (and must not be used for any other purpose).
CJE and its servants, employees and officers otherwise expressly disclaim responsibility to any person other than the
Mr. Jeff Galizio arising from or in connection with this Report.
To the maximum extent permitted by law, all implied warranties and conditions in relation to the services provided by
CJE and the Report are excluded unless they are expressly stated to apply in this Report.
The services undertaken by CJE in connection with preparing this Report:
• were limited to those specifically detailed in the project scope of work.
The opinions, conclusions and any recommendations in this Report are based on assumptions made by CJE when
undertaking services and preparing the Report ("Assumptions'?, including (but not limited to):
• Existing storm drain facilities were sized to function properly.
• This project intends to address the potential additional surface runoff created by proposed changes to the
nature of the structures and pervious and impervious areas on the subject site property.
• The report will study on-site flows and on-site flows. No off-site flows were considered.
• Proposed discharge will be sized to maintain the discharge capacity as the existing points contributing
discharge to Chinquapin Ave.
CJE expressly disclaims responsibility for any error in, or omission from, this Report arising from or in connection with
any of the Assumptions being incorrect.
Subject to the paragraphs in this section of the Report, the opinions, conclusions and any recommendations in this
Report are based on conditions encountered and information reviewed at the time of preparation and may be relied
on for one year or till significant changes to the project site are made, whichever comes first, after which time, CJE
expressly disclaims responsibility for any error in, or omission from, this Report arising from or in connection with
those opinions, conclusions and any recommendations.
Page i
----..
• -..
--..
• -• -• -• -• -• -.. -.. -.. -.. -
-.. ----
-...
-
...
-
•
• --
--
-
...
-...
--.. ..
Table of Contents
Purpose of Study..................................................................................................... 1
Hydrologic Analysis ................................................................................................ .
Hydraulic Analysis .................................................................................................. .
Figures
Figure 1
Appendices
Appendix A
Appendix B
Appendix C
Appendix D
Appendix E
Page ii
Vicinity Map
Rational Hydrology Workmap
Rational Hydrology Analysis
lsopluvial Maps
Hydraulic Calculations, Existing and Proposed Conditions
FEMA FIRM Panel
5
9
Declaration of Responsible Charge
I hereby declare that I am the Engineer of Work for this project, that I have exercised responsible
charge of the design of the project as defined in Section 6703 of the Business and Professions
Code, and that the design is consistent with current standards.
I understand that the check of project drawings and specifications by the City of Carlsbad does not
relieve me, as Engineer of Work, of my responsibilities for project design.
Firm:
Address:
City, State:
Telephone:
By:
Date:
R.C.E.#:
Cory Jones Engineering
1820 S. El Camino Real, Unit A205
Encinitas, CA
619.884.0576
Cory Jones, PE
10/02/2020
69807
Registration Expiration Date: 6/30/2022
Page iii
---------------
• -• ..
• -.. .. .. -.. .. -
----
---
Purpose of Study
This Drainage report presents the hydrologic conditions for the proposed 330 Chinquapin
Avenue project in Carlsbad, CA. This report also provides an evaluation of the pre-
construction and post construction on-site drainage conditions for hydraulic requirements
to meet the standards of the City of Carlsbad. This report also addresses water quality
requirements specifically requested by the City of Carlsbad Engineering Standards.
Project Location
The project is located in the coastal area of the City of Carlsbad, about three blocks north
of Agua Hedionda Lagoon. The site is south of Tamarak Avenue, east of Garfield Avenue,
north of Chinquapin Avenue and west of the LOSAN corridor railroad tracks. The property
is located in the northeasterly half of Lot 3 in blocks of Palisades No. 2 in the City of
Carlsbad, CA, according to Map 1803 as filed in the Office of the County Recorder on
August 24, 1924. The southwesterly boundary line being parallel with and distant from 70
feet southwesterly from the northwesterly line of said lot. The site has Assessor's Parcel
Number (APN) 206-020-11-00. A Vicinity map showing the project's location is provided
in Figure 1.
CJE
Project
Location
\
\
Project Description
V
I
r '.\ • i, .. , I
Figure 1 -Vicinity Map
/ --
.... ----........ ,
J ./
......... q ~ :-.__.
La,oo,t~ •• ,
~ _ .. . /
The 330 Chinquapin project consists of demolition of one existing building at 330
Chinquapin Avenue and creation of a new 7 unit subdivision. There is an existing
residential driveway and asphalt parking lot adjoining the existing building at 330
Chinquapin Avenue. The driveway will remain in approximately the same horizontal
location, but will extend further north to service the three new structures in the south end
of the lot and the multifamily dwelling unit at the north end of the lot. The driveway and
multi-use drainage facilities that will be built as part of this project will be maintained as
part of the new multi-family subdivision, wherein all future maintenance requirements will
be the responsibility of each land owner in perpetuity.
CJE
The project existing and proposed conditions site soils information are described in Table
1. A map of the site soils is provided in Figure 2. The project existing and proposed
conditions site perviousness is described in Table 2.
CJE
Figure 2 -Site Soils Map
CJE
Note that NRCS lists MIC Soil as a
Type B Hydrologic Soil, NRCS Web
Soils Survey also estimates a saturated
hydraulic conductivity for this soil as
15.4 mm/s or but from the Preliminary
Geotechnical Investigation provided by
Group Delta, indicates that the site
consists of:
-3 to 7-ft thick of fill material requiring
over excavation and recompaction
-over 4 to 12-ft thick of Old Paralitic
Deposits that consists of poorly-graded
sand with silt, medium dense, red-
brown, dry to moist, mostly fine to
medium sand, few fines, non-plastic,
weakly cemented
-over 2 to 6-ft thick of Silty Sand or
Poorly Graded Sand that consists of
medium dense, light yelJow-brown,
mostly fine to medium Sand, trace fines,
and friable or dense, orange-brown,
moist, mostly fine to medium sand, non-
plastic weakly cemented materials.
...
--
• -..
-
• .. --...
..
...
...
-..
---
..
...
-
--
An infiltration test was taken from a location in the frontage of the proposed development
using the double-ring infiltrometer test at an estimated elevation of approximately 42-feet.
The infiltration rate observed at this location was estimated to approach 2. 76 inches per
hour, which infers that the site may be good for infiltration of site drainage waters.
However, the Geotechnical Engineer provided the following caveats suggests that a
design infiltration rate of 1.1 in/hr is appropriate of the project duration.
Surrounding Land Uses
The area is urbanized and the surrounding properties consist of multi-unit and single
family residential uses and is located near the residences adjacent to the old Highway
101 corridor, now Carlsbad Boulevard.
CJE
Hydrologic Analysis
Rational Method
This drainage study utilizes the Rational Method to calculate peak flow rates for the 10
and 100 year storm events. The Rational Method is appropriate for sites with watersheds
smaller than 0.5 square miles and is described in detail within the County of San Diego
Hydrology Manual (2003 Ed). This report is using the AES software, approved by the
County of San Diego, to evaluate rational method hydrology estimates for the project site.
Rational Method Runoff Coefficients
For this drainage report, each drainage sub-area basin was determined to have a percent
imperviousness based on existing and proposed conditions mapping. This percent
impervious was used to select a given land use type with similar percent imperviousness.
Therefore, the land uses presented for each sub-basin area are different.
To provide conservative estimates of peak flow rates, the pre-development condition land
use types were selected with land uses that have the same percent imperviousness or
slightly less and the post-development condition land use types were selected with land
uses that have the same percent imperviousness or slightly greater. In this way, the post-
development peak flows will be exact or slightly skewed with higher rates and the pre-
development peak flows will be exact or slightly skewed with lower rates. Therefore,
matching of peak flows to the existing discharge points can be evaluated and may provide
additional comfort with this conservativism.
CJE
------
----• ..
..
• -• -
-..
•
• ---..
----------
-.. .. ..
-----
-
..
•
-..
-..
...
---
•
-
------
Table 1 in Appendix B presents each drainage area sub-area square footages for
pervious and impervious areas and their correlated percent imperviousness and shows
the corresponding land use type selected and it's percent impervious value used in the
AES model.
Intensity
Intensity for the 10 and 100 year storm frequencies was using isopluvial maps from the
County of San Diego Hydrology Manual (see Appendix C) .
Peak Flow Rates and Volumes
Peak flow rates were estimated using the rational method as evaluated by the AES model
and program results along with summary tables of the results are presented in Appendix
B .
The appendix includes the following documents related to peak flow estimates:
• Appendix A contains Maps of the site drainage (existing and proposed conditions),
• Appendix B contains Calculations of hydrology summations to each node (inlets or
other collection locations),
• Appendix D contains drainage schematics for existing and proposed conditions.
• Appendix E contains summations for flow to each sub-area node and node
summations .
• Appendix F contains Hydraulics for conveyances (pipes and channels).
CJE
Table 1. Comparison of 10-Year Peak Flow Rates at Discharge Locations
Flow Direction Q10 pre Q10 post Delta Evaluation
(cfs) (cfs) (cfs)
Discharge To 0.79 1.17 +0.38 Minor increase
Chinquapin in flow to street
Avenue (< 1 cfs)
Table 2. Comparison of 100-Year Peak Flow Rates at Discharge Locations
Flow Direction Q100 pre Q100 post Delta Evaluation
(cfs) (cfs) (cfs)
Discharge To 1.16 1.71 +0.55 Minor increase
Chinquapin in flow to street
Avenue (< 1 cfs)
Based on our analysis, the site appears to only generate a minor increase (less than 1
cfs) in peak storm discharges from the facility. This is a conservative calculation since
infiltration losses were not accounted for by the perforated piping and infiltration capacity
of the new pervious pavement system. The site is underlain with well draining Type A
soils in the vicinity of the project site and the modeling also used an assumption of Type
B soils in modeling to account for any future changes on account of the build-out
environment.
Results Statements
Flow was determined to not increase in a significant manner that would affect drainage
within the street curb-and-gutter flow line from pre-construction to post-construction
condition as demonstrated by calculations.
CJE
-----• --------..
•
•
• -• ..
--
--
-------
-------...
-----
• ---...
-
....
-
-..
--..
--------
From results of our study, there are determined to be no negative impacts to any adjacent
properties.
CJE
Hydraulic Analysis
Methodology
Hydraulic flow calculations and storm drain facility sizing were performed using the
procedures outlines in the County of San Diego Drainage Design Manual (2014 Ed).
Hydraulics
Hydraulic capacities were evaluated for new and existing storm drain inlets and piping
and these evaluations are provided in the attached calculations.
On-site catch basins are sized to accept the 100 year peak discharge to their interior site
drainage locations. These boxes are sized as weirs with length defined as the perimeter
length of the boxes and assuming a clogging factor of 25% since they will be installed
with an inlet filter system to assist in reducing the quantity of solids that will pass to the
sub-grade rock reservoir infiltration gallery.
Note that additional inlet catch basins were added around the perimeter of the facilities
as pick-up locations due to site restrictions lengths and slopes required to develop
drainage swales around the perimeter of the buildings.
Pipe capacities are evaluated with Manning's condition assuming open channel flow
conditions with steady uniform flow.
Design Review
From review of the estimated peak flow rates for the 100-Year design storm, the proposed
new pipes and inlets will provide adequate capacity to drain the property during these
storm events.
CJE
------
-
• ---• -•
•
•
• -• -------.. ----
-------------
• ----
-
--...
...
--
..
-..
-
Water Quality
The project is a Standard Development Project and therefore it is not subject to design
requirements for treatment controls. The project does however provides water quality
volume reductions within the pervious pavement system that can serve as a standard
project storm water best management practice for the 330 Chinquapin Ave. Subdivision.
The project disturbs less than one acre during construction and therefore does not require
a state permitted SWPPP per the Construction General Permit. However, the final project
grading plan will include an erosion and sediment control plan to comply with City
regulations.
The project drainage does not adversely affect any existing US Army Corps of Engineers
jurisdictional waters of the United States. Therefore, the project is not required to obtain
approval from the Regional Water Quality Control Board under Federal Clean Water Act
(CWA) Section 401 nor Section 404.
CJE
..
-..
---
11 .. -.. ..
•
..
-
--
-
CJE --
-... .. ..
-..
-
◄ -..
.. ..
• ..
• ..
-...
-...
..
------
•
• -.. ,.
-..
-
◄
--
CJE
APPENDIX A
RATIONAL HYDROLOGY WORKMAP
/
/
(
/
!
/
./,
I
I I I I I
' I
1
'-,,_ 3· \vO□D
F NCE
I I I
1.1
1.2
48.9'
I
53.27'
CJEI
CORY JONES ENGINEERING
1820 S. EL CAMINO REAL. A205
ENCINITAS, CA 92024
(P) 619-884-0576
EXISTIN:i ~
s-□RY
BU!l DlNG
EXiSTING I
ST[RY
BU!L l!NG
/VIL ~
F CALl'ilJ~
I
' \ )
54.5'
INV48.49' EXISTIN:i 2
s-□RY
BUILDING
49.23'
INV48.15'
OFF-SITE STREET FLOW
Q100=7.20 CFS
V100=3. 7 FPS
.......... ~j!;~~~
0 10· 20·
I •■I i
1 INCH = 10 FT
46.20'
PROJECT NUMBER:
CT2019-0004
A(
~ Y'
/~ T
--H
~
CXJ ~-
/
L=42 '
I
"' r::iv-w---
3.1
48.32"
' w ' .44
--H ~
If) .
0
:
I
A(6)
3:
N
I
t
02
0.08 9.11
N -
3.3
48.00'
3:
N -
I
I
I
I
-w--_J 3:
A(5) .02
0.07 0.11
3:
N -
EXHIBIT 1 -RATIONAL HYDROLOGY WORKMAP
PRE-CONSTRUCTION PROJECT AREA MAP
330 CHINQUAPIN AVE. CARLSBAD CA
LEGEND
10 YR PEAK SUBAREA 00 YR PEAK
FLOW (CFS) (SF) FLOW (CFS)
NODE NUMBER t 1 I
ELEVATION --------..._f 1.0
FLOW DIRECTION
LONGEST FLOW PATH
PER SUBAREA
FINISH SURFACE SPOT GRADE
DRAINAGE AREA BOUNDARY
419±
D
1083SF .02
0.05 0.07
2.2
50. 76'
INV49.6 ' I
I '
J r.,~ X
/I I
/
/147S
I
/
/
,' I/
/
/
1.1 /
-51.0'±
1.2
50.76'
INV49.65'
/
I
/
/
144SF
A
1075SF
.02
0.02 0.03
CJEI
CORY JONES ENGINEERING
1820 S. EL CAMINO REAL, A205
ENCINITAS. CA 92024
(P) 619-884-0576
296SF
399SF
E 03 1370SF ::: . \ '
0.07 0.10
241SF
--Ill--
340SF
2.3
51.0'
1.5
51.0'
397SF
--------------
---------
\
\
L=62'
1.3
51.0'
B
0.06 0.09
1.4
49.95'
INV48.9'
50.15'
0.07 0.10
I
\
II
II
I II
i II '
' II
II
II
II
ii "l-A:l+/i'==="'~, --.-------,
I I
3.3
, 50.5'
)
\
I
II
II
II
II
II
' 'l}-----_J
L=22'
281SF ---
50.5' 50.3'
INV48.3'
817SF
.02
0.06 0.09
' / I
50.5'
G
1590SF
.04 \
0.08 0.11
H
2643SF
.06
2001SF
L
s
1*34SF
.03
0.12 0.17
8.4 o.ru'· · -1, 1
1 • ~ 44.5'
N
0.07 0.10 -I "" _,...,,,--_.,.,,,.
• 1 ~ , 1 "-'"-l}IS8HA POINT I
I
3.6
"-.) ~ ,, ' -
837SF "'"/ • ~, ,I . • -( CHINQ flN AVE)
~~-,M ~ .02.
54
"' ' 7.2 , _,':'l.~ 010= .96!"CFS t
• 5.2 1-----+------1 • , '\ 0~9----8:91 CFS Mf
__.,-~1 -,-48-.-4-. ----J o.o,6 o.~9 48.3' 46.3' <\11 = 6.2 FPS
~ l j x '<----------"~"-d.---------l.____ _ _j • 00=6. 9 FPS t
~~ . ~
, " 1,
1
__________ I
. ;, . . 8 --~ 11 I\
II '
-5.1 " \
'
1
' '
/ 11 \
1 II
' II
' I
I
5.3 1-::---:~T--~~
' I I
' ' ' ' ' .
~, ~-, j ---I
~""'"'" ~ i'\ , CHINQUAP AVE) "?
!, -1 _ '.-l 80=·1--:-43 CFS ~
I ,: 1 · l1 4. FPS I
5.5
49.0'
:;:
_: 49.25' 1 II ' 1
II 1
,' : I 49.25' , :
L__ __ __,' '
I \
I \
, , , I
I I I N
·,
---,._
' -97'
/ ; ~~:,,,,"' 1
' 1
II ' I ' 1 ' '
II
I, \ I I 'I
-~_-_L_-_-_...J_L_:: _;;_ _L __ -_-' ______ '::,_--=..--=._.l._-::._· .,
' I < ' ' .
_j IT,] I'
'
22:'1:Sf-..: -•
0.07 0.10
-iiiiiiiiiil;:--IIJI! ~~~
0 1 o· 20·
I I I
1 INCH = 10 FT
w ' I
I
-H ~
I.() .
0
<(
z
o_
<(
8.2
46.9'
8.3
48.05'
2019-0004
EXHIBIT 2 -RATIONAL HYDROLOGY WORKMAP
I
I
l
:;:
N
I
I
I
I
I :;:
N -
POST-CONSTRUCTION PROJECT AREA MAP
330 CHINQUAPIN AVE CARLSBAD CA
LEGEND
OFF-SITE FLOW TO STREET
UPSTREAM OF PROJECT FRONTAGE
SUBAREA NAME-.... A1 ----....... UBAREA (AC)
f----------1-----1
.2 8~
10 .44
4.79 7.20
DRAINAGE SUB-G; ~
AREA BOUNDARY 189SF1
DRAINAGE SUB~
AREA (SF)
10 YR PEAK SUBAREA'-100 YR PEAK
FLOW (CFS) (SF) FLOW (CFS)
--
NODE NUMBER f 1 I
ELEVATION ------------<f►_ 1.0 _
FLOW DIRECTION
LONGEST FLOW PATH
PER SUBAREA
FINISH SURFACE SPOT GRADE
DRAINAGE AREA BOUNDARY
419±
-..
...
--
....
-...
-..
-
•
• ..
•
•
... ..
...
•
•
•
•
•
• ..
• .. -...
--.. --.. --
CJE
APPENDIX B
RATIONAL HYDROLOGY ANALYSIS
Actual
% Impervious
24.56%
424 0.01 0.02 52.35%
645 906 0.01 0.02 71.19%
620 1,083 0.01 0.02 57.25%
953 1,370 0.02 0.03 69.56%
1,153 707 1,860 0.02 0.04 38.01%
924 666 1, 0. 41.89%
2,137 507 2,643 0.01 0.06 19.16%
359 458 817 0.01 0.02 56.06%
448 204 652 0.00 0.01 31.29%
374 215 589 0.00 0.01 36.50%
1,022 979 2,001 0.02 0.0 48.93%
377 460 837 0.01 0.02 54.96%
147 331 478 0.01 0.01 69.25%
160 547 707 0.01 0.02 77.37%
306 381 687 0.01 0.02 55.46%
79 634 713 0.01 0.02 88.92%
9,824 8,995 18,818 0.21 0.4
142 738 880 0.02 0.02 83.86%
33 1, 1 1, 3 .03 97.33%
9,999 10,934 20,932 0.25 0.48
0 0.00%
2,396 0.06 0.27 20.33%
1,726 0.04 0.06 69.32%
1,200 1,388 2,588 0.0 53.63%
111 629 740 0.01 0.02 84.99%
915 980 0.02 0.02 90.97%
1 ,2 3 0.
13,745 7,054 20,932 0.
AES AES AES AES
AES AES 10-YR 10-YR 100-YEAR 100-YEAR
%impervious Land Use Tc(MIN) Q(CFS) Tc {MIN) Q(CFS)
#
25% 2.9 DU/AC 3 11.06 0.02 11.06 0.03
65% 24 DU/AC 8 5.11 0.06 5.11 0.09
80% 43 DU/AC 9 3.28 0.07 3.28 0.1
65% 24 DU/AC 8 6.9 0.05 6.9 0.07
80% 43 DU/AC 9 3.71 0.07 3.71 0.1
40% 7.3 DU/AC 5 7.91 0.07 7.91 0.1
45% 10.9 DU/AC 6 7.11 0.08 7.11 0.11
20% 2.0 DU/AC 2 9.55 0.07 9.55 0.1
65% 24 DU/AC 8 3.75 0.06 3.75 0.09
40% 7.3 DU/AC 5 4.85 0.02 4.85 0.03
40% 7.3 DU/AC 5 6.52 0.02 6.52 0.03
50% 14.5 DU/AC 7 7.66 0.1 7.66 0.15
65% 24 DU/AC 8 4.35 0.06 4.35 0.09
80% 43 DU/AC 9 3.93 0.03 3.93 0.05
80% 43 DU/AC 9 4.73 0.07 4.73 0.1
65% 24 DU/AC 8 6.32 0.05 6.32 0.08
90% Office Comm. 12 2.28 0.08 2.28 0.11
85% Gen. Comm. 11 2.2 0.07 2.2 0.11
100% Paved, curbs & SD 16 1.8 0.12 1.8 0.17
0% WstrnDsrt Landscape 21 9.36 0.04 9.36 0.05
10% 1.0 DU/AC 1 9.36 0.32 9.36 0.48
65% 24 DU/AC 8 4.32 0.18 4.32 0.26
50% 14.5 DU/AC 7 7.52 0.1 7.52 0.15
85% Gen. Comm. 11 2.04 0.07 2.04 0.11
90% Office Comm. 12 1.25 0.08 1.25 0.11
13.14 4.79 12.72 7.2
-.. ..
...
... ------
-
•
-
• -
..
•
--
-
..
• .. ..
RESULTS FROM AES HYDROLOGY PROGRAM
PRE-DEVELOPMENT RATIONAL METHOD RESULTS
DRAINAGE AREA NODE FROM NODETO AREA
AC
Al 1.1 1.2 0.05
A2 1.2 3.4 0.27
A3 2.1 2.2 0.06
A4 2.3 2.4 0.06
ON-SITE SUM
AS 3.1 3.2 0.02
AG 3.3 3.4 0.02
FRONTAGE ROW SUM
TOTAL
Ql0 Tc 10 Ql00 Tel00
CFS MIN CFS MIN
0.04 9.36 0.05 9.36
0.32 9.36 0.48 9.36
0.18 4.32 0.26 4.32
0.1 7.52 0.15 7.52
0.64 0.94
0.07 2.04 0.11 2.04
0.08 1.25 0.11 1.25
0.15 0.22
0.79 1.16
RESULTS FROM AES HYDROLOGY PROGRAM
POST-DEVELOPMENT RATIONAL METHOD RESULTS
DRAINAGE AREA NODE FROM NODETO AREA
AC
A (1.1-1.2) 1.1 1.2 0.02
B (1.3-1.4) 1.3 1.4 0.02
C (1.5-1.6) 1.5 1.6 0.02
D (1.1-2.2) 1.1 2.2 0.02
E (2.3-2.4) 2.3 2.4 0.03
F (3.1-3.2) 3.1 3.2 0.04
G (3.3-3.4) 3.3 3.4 0.04
H (3.5-3.6} 3.5 3.6 0.06
I (4.1-4.2} 4.1 4.2 0.02
J (4.3-4.4) 4.3 4.4 0.01
K (5.1-4.6} 5.1 4.6 0.01
L (5.1-5.2) 5.1 5.2 0.05
M (5.3-5.4} 5.3 5.4 0.02
N (5.3-5.5) 5.3 5.5 0.01
0 (6.1-6.2) 6.1 6.2 0.02
P (6.3-6.4) 6.3 6.4 0.02
Q (5.3-7.2} 5.3 7.2 0.02
ON-SITE SUM
R (8.1-8.2) 8.1 8.2 0.02
S (8.3-8.4) 8.3 8.4 0.03
FRONTAGE ROW SUM
TOTAL
Ql0
CFS
0.02
0.06
0.07
0.05
0.07
0.07
0.08
0.07
0.06
0.02
0.02
0.1
0.06
0.03
0.07
0.05
0.08
0.98
0.07
0.12
0.19
1.17
-----Tc 10 Ql00 Tel00 -MIN CFS MIN
11.06 0.03 11.06 -5.11 0.09 5.11 -3.28 0.1 3.28
6.9 0.07 6.9 -
3.71 0.1 3.71 -7.91 0.1 7.91
7.11 0.11 7.11
9.55 0.1 9.55
3.75 0.09 3.75
4.85 0.03 4.85 -
6.52 0.03 6.52
7.66 0.15 7.66
4.35 0.09 4.35 -
3.93 0.05 3.93 -4.73 0.1 4.73 -6.32 0.08 6.32
2.28 0.11 2.28 -1.43 -2.2 0.11 2.2
1.8 0.17 1.8
0.28 -1.71 • ---------.. -
---..
--.. .. .. -----..
•
• ..
•
•
-..
• ..
--
•
•
-...
----
•
• -..
• ..
•
•
CJE
PRE-DEVELOPMENT
10-YEAR DESIGN STORM
AES CALCULATION REPORTS
--..
... .. ---
•
• -
..
• --..
•
• ..
•
• ..
•
•
.. ..
CQR10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
**************************
* 330 CHINQUAPIN AVE
DESCRIPTION OF STUDY **************************
* * AREA Al+A2
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQR10.DAT
TIME/DATE OF STUDY: 16:20 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) ====== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
NATURAL DESERT LANDSCAPING RUNOFF COEFFICIENT= .2500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 77
INITIAL SUBAREA FLOW-LENGTH(FEET) = 100.00
UPSTREAM ELEVATION(FEET) = 53.27
DOWNSTREAM ELEVATION(FEET) = 48.90
ELEVATION DIFFERENCE(FEET) = 4.37
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 9.359
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.989
Page 1
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
CQR10.RES
0.04
0.05 TOTAL RUNOFF(CFS) = 0.04
****************************************************************************
FLOW PROCESS FROM NODE 1. 20 TO NODE 3.40 IS CODE= 81
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.989
RESIDENTIAL (1. DU/AC OR LESS) RUNOFF COEFFICIENT=
SOIL CLASSIFICATION IS 11B11
S.C.S. CURVE NUMBER (AMC II)=
AREA-AVERAGE RUNOFF COEFFICIENT 65
= 0. 3100
.3200
SUBAREA AREA(ACRES) = 0.30
TOTAL AREA(ACRES) = 0.4
SUBAREA RUNOFF(CFS) =
TOTAL RUNOFF(CFS) =
TC(MIN.) = 9.36
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.4 TC(MIN.) =
0.32
END OF RATIONAL METHOD ANALYSIS
Page 2
9.36
0.29
0.32
-----------------
-
• ------------------
-..
-
-----
-
• -
• -
-
•
--•
..
..
..
• ..
• ..
CQRA310. RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE
* AREA A3
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQRA310.DAT
TIME/DATE OF STUDY: 15:57 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL 11C11-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* * *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.10 TO NODE 2.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 61.00
UPSTREAM ELEVATION(FEET) = 56.17
DOWNSTREAM ELEVATION(FEET) = 54.50
ELEVATION DIFFERENCE(FEET) = 1.67
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.321
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
CQRA310.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.18
TOTAL AREA(ACRES) = 0.06 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.1 TC(MIN.) =
0.18
END OF RATIONAL METHOD ANALYSIS
Page 2
0.18
4.32
----
-------------
----------..
--------
•
-
..
-..
•
•
•
--.. .. -
•
• .. ..
-..
-..
---
.. -.. -
CQRA410.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
**************************
* 330 CHINQUAPIN AVE
DESCRIPTION OF STUDY **************************
* * AREA A4
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQRA410.DAT
TIME/DATE OF STUDY: 16:01 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.30 TO NODE 2.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT= .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
INITIAL SUBAREA FLOW-LENGTH(FEET) = 76.00
UPSTREAM ELEVATION(FEET) = 50.00
DOWNSTREAM ELEVATION(FEET) = 49.23
ELEVATION DIFFERENCE(FEET) = 0.77
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.525
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQRA410. RES
THE MAXIMUM OVERLAND FLOW LENGTH= 65.20
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.441
SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.05 TOTAL RUNOFF(CFS) = 0.10
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) = 0.1 TC(MIN.) =
0.10
END OF RATIONAL METHOD ANALYSIS
Page 2
7.52
-----• ------------..
• -
-..
--
-----------
◄
..
CQRA510.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
**************************
* 330 CHINQUAPIN AVE
DESCRIPTION OF STUDY **************************
* * AREA AS
* 10 YEAR RECURRENCE DESIGN STORM **************************************************************************
FILE NAME: CQRA510.DAT
TIME/DATE OF STUDY: 16:06 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) Constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.10 TO NODE 3.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
GENERAL COMMERCIAL RUNOFF COEFFICIENT= .8000
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 92
INITIAL SUBAREA FLOW-LENGTH(FEET) = 42.00
UPSTREAM ELEVATION(FEET) = 48.32
DOWNSTREAM ELEVATION(FEET) = 46.20
ELEVATION DIFFERENCE(FEET) = 2.12
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.040
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
-'i'-
CQRA510.RES
NOTE: RAINFALL INTENSITY IS BASED ON TC= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
2.04
•
•
0.07
..
..
•
..
..
..
•
..
..
..
•
..
•
..
..
•
4
..
•
..
..
•
•
..
CQRA610. RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA A6 *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQRA610.DAT
TIME/DATE OF STUDY: 16:09 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.30 TO NODE 3.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT= .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 94
INITIAL SUBAREA FLOW-LENGTH(FEET) = 33.00
UPSTREAM ELEVATION(FEET) = 48.00
DOWNSTREAM ELEVATION(FEET) = 44.45
ELEVATION DIFFERENCE(FEET) = 3.55
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 1.248
WARNING: THE MAXIMUM OVERLAND FLOW SLOPE, 10.%, IS USED IN Tc CALCULATION!
Page 1
CQRA610.RES
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.08
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.08
END OF RATIONAL METHOD ANALYSIS
Page 2
0.08
1. 25
•
..
•
..
•
•
..
..
..
..
•
"
•
•
• ..
..
..
" -
..
•
CQUS10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA UPSTREAM TO DETERMINE APPROXIMATE STREETFLOW AT CURBLINE *
* 10 YEAR RECURRENCE DESIGN STORM * **************************************************************************
FILE NAME: CQRUS10.DAT
TIME/DATE OF STUDY: 16:46 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 10.10 TO NODE 10.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT= .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
INITIAL SUBAREA FLOW-LENGTH(FEET) = 100.00
UPSTREAM ELEVATION(FEET) = 71.00
DOWNSTREAM ELEVATION(FEET) = 70.00
ELEVATION DIFFERENCE(FEET) = 1.00
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.546
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQUS10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 65.00
(Reference: Table 3-lB of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.435
SUBAREA RUNOFF(CFS) = 0.22
TOTAL AREA(ACRES) = 0.11 TOTAL RUNOFF(CFS) = 0.22
****************************************************************************
FLOW PROCESS FROM NODE 10.20 TO NODE 10.30 IS CODE= 62
>>>>>COMPUTE STREET FLOW TRAVEL TIME THRU SUBAREA<<<<<
>>>>>(STREET TABLE SECTION# l USED)<<<<<
UPSTREAM ELEVATION(FEET) = 70.00 DOWNSTREAM ELEVATION(FEET) = 48.50
STREET LENGTH(FEET) = 1015.00 CURB HEIGHT(INCHES) = 8.0
STREET HALFWIDTH(FEET) = 30.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK(FEET) = 20.00
INSIDE STREET CROSSFALL(DECIMAL) = 0.018
OUTSIDE STREET CROSSFALL(DECIMAL) = 0.018
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF= 1
STREET PARKWAY CROSSFALL(DECIMAL) = 0.020
Manning's FRICTION FACTOR for Streetflow section(curb-to-curb) = 0.0150
Manning's FRICTION FACTOR for Back-of-walk Flow section= 0.0200
**TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) =
STREETFLOW MODEL RESULTS USING ESTIMATED FLOW:
STREET FLOW DEPTH(FEET) = 0.32
HALFSTREET FLOOD WIDTH(FEET) = 8.59
AVERAGE FLOW VELOCITY(FEET/SEC.) = 3.02
PRODUCT OF DEPTH&VELOCITY(FT*FT/SEC.) = 0.96
STREET FLOW TRAVEL TIME(MIN.) = 5.59 Tc(MIN.) =
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.402
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT=
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
AREA-AVERAGE RUNOFF COEFFICIENT= 0.580
13.14
.5800
SUBAREA AREA(ACRES) = 3.33
TOTAL AREA(ACRES) = 3.4
SUBAREA RUNOFF(CFS) =
PEAK FLOW RATE(CFS) =
END OF SUBAREA STREET FLOW HYDRAULICS:
DEPTH(FEET) = 0.37 HALFSTREET FLOOD WIDTH(FEET) = 11.60
2.58
4.64
4.79
FLOW VELOCITY(FEET/SEC.) = 3.43 DEPTH*VELOCITY(FT*FT/SEC.) = 1.27
LONGEST FLOWPATH FROM NODE 10.10 TO NODE 10.30 = 1115.00 FEET.
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
3.4 TC(MIN.) =
4.79
END OF RATIONAL METHOD ANALYSIS
Page 2
13.14
..
..
..
•
•
..
..
..
..
..
..
•
..
..
..
..
..
•
------------..
• .. ..
----
• -.. -.. ..
-
• ---.. .. .. .. ---
CJE
PRE-DEVELOPMENT
100-YEAR DESIGN STORM
AES CALCULATION REPORTS
---
----..
.. -..
• ..
• .. --
-•
----
41
--..
.. -
-
CQRlOO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 330 CHINQUAPIN AVE
* AREA Al+A2
* 100 YEAR RECURRENCE DESIGN STORM
**************************
* * * **************************************************************************
FILE NAME: CQR100.DAT
TIME/DATE OF STUDY: 16:24 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
NATURAL DESERT LANDSCAPING RUNOFF COEFFICIENT= .2500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 77
INITIAL SUBAREA FLOW-LENGTH(FEET) = 100.00
UPSTREAM ELEVATION(FEET) = 53.27
DOWNSTREAM ELEVATION(FEET) = 48.90
ELEVATION DIFFERENCE(FEET) = 4.37
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 9.359
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.396
Page 1
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
CQR100.RES
0.05
0.05 TOTAL RUNOFF(CFS) = 0.05
****************************************************************************
FLOW PROCESS FROM NODE 1. 20 TO NODE 3.40 IS CODE= 81
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.396
RESIDENTIAL (1. DU/AC OR LESS) RUNOFF COEFFICIENT=
SOIL CLASSIFICATION IS 11B11
S.C.S. CURVE NUMBER (AMC II)=
AREA-AVERAGE RUNOFF COEFFICIENT
65 = 0.3100
.3200
SUBAREA AREA(ACRES) = 0.30
TOTAL AREA(ACRES) = 0.4
SUBAREA RUNOFF(CFS) =
TOTAL RUNOFF(CFS) =
TC(MIN.) = 9.36
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.4 TC(MIN.) =
0.48
END OF RATIONAL METHOD ANALYSIS
Page 2
9.36
0.42
0.48
---• -
-----------
-
------------------
..
•
"
•
•
4
"
..
•
•
..
..
• ..
CQRA3100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA A3 *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQRA3100.DAT
TIME/DATE OF STUDY: 15:59 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.10 TO NODE 2.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 61.00
UPSTREAM ELEVATION(FEET) = 56.17
DOWNSTREAM ELEVATION(FEET) = 54.50
ELEVATION DIFFERENCE(FEET) = 1.67
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.321
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
-'?-
CQRA3100.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.26
TOTAL AREA(ACRES) = 0.06 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0 .1 TC(MIN.) =
0.26
END OF RATIONAL METHOD ANALYSIS
Page 2
0.26
4.32
..
..
..
• ..
• ..
..
•
..
..
" ..
..
..
...
• ..
• ..
..
..
• ..
..
..
..
..
" ..
..
•
•
..
..
..
..
..
...
..
..
•
•
..
..
..
.. ..
CQRA4100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering Software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA A4 *
* 100 YEAR RECURRENCE DESIGN STORM * **************************************************************************
FILE NAME: CQRA4100.DAT
TIME/DATE OF STUDY: 16:04 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.30 TO NODE 2.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT= .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
INITIAL SUBAREA FLOW-LENGTH(FEET) = 76.00
UPSTREAM ELEVATION(FEET) = 50.00
DOWNSTREAM ELEVATION(FEET) = 49.23
ELEVATION DIFFERENCE(FEET) = 0.77
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.525
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQRA4100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 65.20
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN TC CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.060
SUBAREA RUNOFF(CFS) = 0.15
TOTAL AREA(ACRES) = 0.05 TOTAL RUNOFF(CFS) = 0.15
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0 . 1 TC (MIN • ) =
0.15
END OF RATIONAL METHOD ANALYSIS
Page 2
7.52
..
• -
• .. ..
•
•
..
..
•
..
..
..
•
..
..
..
-..
..
• ..
• -
• -..
-
•
.. ..
•
-..
•
•
..
--
-
• ..
•
•
•
•
---
•
•
-------..
-
--
CQRA5100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 330 CHINQUAPIN AVE
**************************
* * AREA AS
* 100 YEAR RECURRENCE DESIGN STORM **************************************************************************
FILE NAME: CQRA5100.DAT
TIME/DATE OF STUDY: 16:08 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "("-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.10 TO NODE 3.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
GENERAL COMMERCIAL RUNOFF COEFFICIENT= .8000
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 92
INITIAL SUBAREA FLOW-LENGTH(FEET) = 42.00
UPSTREAM ELEVATION(FEET) = 48.32
DOWNSTREAM ELEVATION(FEET) = 46.20
ELEVATION DIFFERENCE(FEET) = 2.12
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.040
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
CQRA5100.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.11
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.11
END OF RATIONAL METHOD ANALYSIS
Page 2
0.11
2.04
-...
-----
----
..
-
-------..
-
• -----------
..
..
..
..
4
..
..
..
•
..
•
..
•
..
•
..
..
..
..
..
• ..
CQRA6100. RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA AG *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQRA6100.DAT
TIME/DATE OF STUDY: 16:10 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.30 TO NODE 3.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT= .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 94
INITIAL SUBAREA FLOW-LENGTH(FEET) = 33.00
UPSTREAM ELEVATION(FEET) = 48.00
DOWNSTREAM ELEVATION(FEET) = 44.45
ELEVATION DIFFERENCE(FEET) = 3.55
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 1.248
WARNING: THE MAXIMUM OVERLAND FLOW SLOPE, 10.%, IS USED IN Tc CALCULATION!
Page 1
CQRA6100. RES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.11
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.11
END OF RATIONAL METHOD ANALYSIS
Page 2
0.11
1. 25
• ..
•
•
•
•
" .. ..
•
..
..
..
..
..
• ..
-..
•
..
.. ..
-
• ..
• ..
• ..
-
•
•
...
•
------
-
-
..
--.. ..
• .. --..
-
..
-.. .. -.. -
CQUS100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA UPSTREAM TO DETERMINE APPROXIMATE STREETFLOW AT CURBLINE *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQUS100.DAT
TIME/DATE OF STUDY: 16:49 07/30/2020
USER SPECIFIED HYDROLOGY ANO HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== === -----
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (oepth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 10.10 TO NOOE 10.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT= .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
INITIAL SUBAREA FLOW-LENGTH(FEET) = 100.00
UPSTREAM ELEVATION(FEET) = 71.00
DOWNSTREAM ELEVATION(FEET) = 70.00
ELEVATION DIFFERENCE(FEET) = 1.00
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.546
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQUS100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 65.00
(Reference: Table 3-lB of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN TC CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.051
SUBAREA RUNOFF(CFS) = 0.32
TOTAL AREA(ACRES) = 0.11 TOTAL RUNOFF(CFS) = 0.32
****************************************************************************
FLOW PROCESS FROM NODE 10.20 TO NODE 10.30 IS CODE= 62
>>>>>COMPUTE STREET FLOW TRAVEL TIME THRU SUBAREA<<<<<
>>>>>(STREET TABLE SECTION# 1 USED)<<<<<
UPSTREAM ELEVATION(FEET) = 70.00 DOWNSTREAM ELEVATION(FEET) = 48.50
STREET LENGTH(FEET) = 1015.00 CURB HEIGHT(INCHES) = 8.0
STREET HALFWIDTH(FEET) = 30.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK(FEET) = 20.00
INSIDE STREET CROSSFALL(DECIMAL) = 0.018
OUTSIDE STREET CROSSFALL(DECIMAL) = 0.018
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF= 1
STREET PARKWAY CROSSFALL(DECIMAL) = 0.020
Manning's FRICTION FACTOR for Streetflow section(curb-to-curb) = 0.0150
Manning's FRICTION FACTOR for Back-of-walk Flow section= 0.0200
**TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) =
STREETFLOW MODEL RESULTS USING ESTIMATED FLOW:
STREET FLOW DEPTH(FEET) = 0.35
HALFSTREET FLOOD WIDTH(FEET) = 10.51
AVERAGE FLOW VELOCITY(FEET/SEC.) = 3.27
PRODUCT OF DEPTH&VELOCITY(FT*FT/SEC.) = 1.15
STREET FLOW TRAVEL TIME(MIN.) = 5.17 Tc(MIN.) =
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.608
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT=
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
AREA-AVERAGE RUNOFF COEFFICIENT= 0. 580
12. 72
.5800
SUBAREA AREA(ACRES) = 3.33
TOTAL AREA(ACRES) = 3.4
SUBAREA RUNOFF(CFS) =
PEAK FLOW RATE(CFS) =
END OF SUBAREA STREET FLOW HYDRAULICS:
DEPTH(FEET) = 0.41 HALFSTREET FLOOD WIDTH(FEET) = 13.87
3.86
6.97
7.20
FLOW VELOCITY(FEET/SEC.) = 3.77 DEPTH*VELOCITY(FT*FT/SEC.) = 1.55
LONGEST FLOWPATH FROM NODE 10.10 TO NODE 10.30 = 1115.00 FEET.
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
3.4 TC(MIN.) =
7.20
END OF RATIONAL METHOD ANALYSIS
Page 2
12.72
-------
---
------------------------
-
..
•
•
..
•
..
•
•
..
•
"
..
•
•
.,
•
..
,,.
..
• ..
• ..
CJE
POST-DEVELOPMENT
10-YEAR DESIGN STORM
AES CALCULATION REPORTS
..
..
•
•
• ..
..
..
..
"'
..
◄
.. ..
CQTA10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY **************************
* * *
* 330 CHINQUAPIN AVE
* AREA A
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTA10.DAT
TIME/DATE OF STUDY: 13:03 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2.9 DU/AC OR LESS) RUNOFF COEFFICIENT= .4100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 70
INITIAL SUBAREA FLOW-LENGTH(FEET) = 52.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 50.76
ELEVATION DIFFERENCE(FEET) = 0.24
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 11.065
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTA10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 50.00
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.683
SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) = 0.02
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.02
END OF RATIONAL METHOD ANALYSIS
Page 2
11.06
• ..
• ..
.. ..
-
• -
•
..
..
..
• ..
•
•
•
-
-..
-
• -
• -
• -.. .. ..
•
•
"
..
•
..
..
CQTB10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA B *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTB10.DAT
TIME/DATE OF STUDY: 13:07 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== === -----1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.30 TO NODE 1.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 62.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 49.95
ELEVATION DIFFERENCE(FEET) = 1.05
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 5.113
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.415
Page 1
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTB10.RES
0.06
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.06
END OF RATIONAL METHOD ANALYSIS
Page 2
0.06
5.11
..
..
•
•
"
•
•
•
..
..
..
..
..
..
•
•
..
..
..
..
..
..
..
• -..
---
-----
-..
-
-
..
• .. ----
-.. ..
-
--.. -
CQTC10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
**************************
* 330 CHINQUAPIN AVE
DESCRIPTION OF STUDY **************************
* * AREA C
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTAC10.DAT
TIME/DATE OF STUDY: 13:06 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/s)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1. 50 TO NODE 1.60 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 47.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 50.10
ELEVATION DIFFERENCE(FEET) = 0.90
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.279
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
CQTC10.RES
NOTE: RAINFALL INTENSITY IS BASED ON TC= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
3.28
-----0.07 -
-----------------------------
--
-
---... .. ..
•
•
•
..
...
..
•
• ..
..
..
•
•
•
•
•
•
•
CQTD10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 330 CHINQUAPIN AVE
* AREA D
* 10 YEAR RECURRENCE DESIGN STORM
**************************
* * * **************************************************************************
FILE NAME: CQTD10.DAT
TIME/DATE OF STUDY: 13:10 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.50 TO NODE 2.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 54.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 50.76
ELEVATION DIFFERENCE(FEET) = 0.24
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.895
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTD10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 50.00
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN TC CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.640
SUBAREA RUNOFF(CFS) = 0.05
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) = 0.05
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.05
END OF RATIONAL METHOD ANALYSIS
Page 2
6.90
------..
• ..
----
.. ..
• ---..
... --
• -...
-
• -..
.. ..
-..
-...
..
..
...
..
...
• ..
..
•
..
1
CQTE10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY **************************
* * *
* 330 CHINQUAPIN AVE
* AREA E
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTE10.DAT
TIME/DATE OF STUDY: 13:11 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.30 TO NODE 2.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 65.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 49.60
ELEVATION DIFFERENCE(FEET) = 1.40
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.708
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
CQTElO.RES
NOTE: RAINFALL INTENSITY IS BASED ON TC= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
0.07
3.71
-----
• ..
• -..
• -
...
..
..
..
•
..
..
..
..
..
..
•
..
•
..
..
•
•
CQTF10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY **************************
* * *
* 330 CHINQUAPIN AVE
* AREA F
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTF10.DAT
TIME/DATE OF STUDY: 13:13 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL 11C11-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE/ SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== === -----1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.10 TO NODE 3.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT= .5100
SOIL CLASSIFICATION IS 11B11
S.C.S. CURVE NUMBER (AMC II)= 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 77.00
UPSTREAM ELEVATION(FEET) = 50.15
DOWNSTREAM ELEVATION(FEET) = 49.00
ELEVATION DIFFERENCE(FEET) = 1.15
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.906
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTF10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 72.40
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN TC CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.333
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.04 TOTAL RUNOFF(CFS) = 0.07
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
7.91
..
"
..
..
•
..
•
..
..
..
-..
--
-----
•
• ---..
--
• --
--
.. ---.. ---
CQTGlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA G *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTG10.DAT
TIME/DATE OF STUDY: 13:15 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.30 TO NODE 3.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (10.9 DU/AC OR LESS) RUNOFF COEFFICIENT= .5400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 78
INITIAL SUBAREA FLOW-LENGTH(FEET) = 83.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 48.79
ELEVATION DIFFERENCE(FEET) = 1.71
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.112
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTG10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 80.60
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN TC CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.568
SUBAREA RUNOFF(CFS) = 0.08
TOTAL AREA(ACRES) = 0.04 TOTAL RUNOFF(CFS) = 0.08
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) = 0.0 TC(MIN.) =
0.08
END OF RATIONAL METHOD ANALYSIS
Page 2
7.11
----
-
--
----..
-..
--------------------
..
..
CQTHlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY **************************
* * *
* 330 CHINQUAPIN AVE
* AREA H
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTH10.DAT
TIME/DATE OF STUDY: 13:17 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.50 TO NODE 3.60 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT= .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 68
INITIAL SUBAREA FLOW-LENGTH(FEET) = 100.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 48.59
ELEVATION DIFFERENCE(FEET) = 1.91
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 9.554
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTH10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 83.65
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.950
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.06 TOTAL RUNOFF(CFS) = 0.07
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0. 1 TC (MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
=====
9.55
•
..
•
..
•
•
..
------------
-
----
-----..
--..
----.. -
CQTI10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA I * * 10 YEAR RECURRENCE DESIGN STORM * **************************************************************************
FILE NAME: CQTI10.DAT
TIME/DATE OF STUDY: 13:18 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 4.10 TO NODE 4.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 22.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 50.30
ELEVATION DIFFERENCE(FEET) = 0.20
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.748
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
CQTI10.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.06
END OF RATIONAL METHOD ANALYSIS
Page 2
3.75
-----
0.06 ---------
----------------------
..
4
•
•
..
..
..
•
•
CQTJ10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE
* AREA J
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTJ10.DAT
TIME/DATE OF STUDY: 13:19 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL 11C11-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* * *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 4.30 TO NODE 4.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT= .5100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 49.89
ELEVATION DIFFERENCE(FEET) = 0.61
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.845
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
CQTJ10.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.02
END OF RATIONAL METHOD ANALYSIS
Page 2
0.02
4.85
•
..
..
..
..
..
..
..
..
•
" ..
..
•
..
..
• -..
-..
----
• -
..
•
CQTK10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY **************************
* 330 CHINQUAPIN AVE
* AREA K
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTK10.DAT
TIME/DATE OF STUDY: 13:21 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* * *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.10 TO NODE 4.50 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT= .5100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.00
ELEVATION DIFFERENCE(FEET) = 0.25
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.523
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.773
Page 1
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTK10.RES
0.02
0.01 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.02
END OF RATIONAL METHOD ANALYSIS
Page 2
0.02
6. 52
..
•
•
..
•
..
..
•
..
..
..
..
•
..
..
..
..
..
..
..
• ..
..
..
•
•
•
..
..
CQTL10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 330 CHINQUAPIN AVE
*AREAL
* 10 YEAR RECURRENCE DESIGN STORM
**************************
* * * **************************************************************************
FILE NAME: CQTL10.DAT
TIME/DATE OF STUDY: 13:22 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.10 TO NODE 5.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT= .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
INITIAL SUBAREA FLOW-LENGTH(FEET) = 97.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 48.40
ELEVATION DIFFERENCE(FEET) = 0.85
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.657
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTL10.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 61.29
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.402
SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.05 TOTAL RUNOFF(CFS) = 0.10
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0 . 1 TC (MIN . ) =
0.10
END OF RATIONAL METHOD ANALYSIS
Page 2
7.66
======
..
• ..
..
•
" ..
•
..
..
..
..
..
..
•
..
..
..
•
•
..
..
..
•
•
•
•
..
-
--------
-
-
• -
...
..
-------.. ..
----
CQTMlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA M *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTM10.DAT
TIME/DATE OF STUDY: 13:24 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.30 TO NODE 5.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 49.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 48.30
ELEVATION DIFFERENCE(FEET) = 0.95
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.345
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTM10.RES
IS BASED ON TC= 5-MINUTE.
0.06
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.06
END OF RATIONAL METHOD ANALYSIS
Page 2
4.35
----
0.06 -------------
---.. -• ------------
-
----
--
-
-
•
-...
--..
---
..
..
..
-.. -
CQTNlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA N *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTN10.DAT
TIME/DATE OF STUDY: 13:25 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "("-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
=== -----1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.30 TO NODE 5.50 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 35.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.00
ELEVATION DIFFERENCE(FEET) = 0.25
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.931
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTN10.RES
IS BASED ON TC= 5-MINUTE.
0.03
0.01 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
3.93
.. --.. ..
0.03 •
• -..
-------..
-------..
-----------
..
•
•
..
"
...
•
CQTOlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA O *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQT010.DAT
TIME/DATE OF STUDY: 13:27 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
=== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.10 TO NODE 6.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.15
ELEVATION DIFFERENCE(FEET) = 0.10
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.733
WARNING: THE MINIMUM OVERLAND FLOW SLOPE, 0.5%, IS USED IN TC CALCULATION!
Page 1
CQTOlO.RES
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) = 0.07
============= END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
4.73
•
..
..
..
•
•
•
•
•
•
..
..
.
..
•
...
•
•
..
..
..
..
..
..
..
" ..
..
..
..
..
•
-
•
-..
-...
-..
•
• ..
• ..
.. ..
-..
-
•
... ..
-
-... .. .. .. ..
.. .. .. -
CQTPlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD tONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA P *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTP10.DAT
TIME/DATE OF STUDY: 13:28 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.30 TO NODE 6.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 42.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.15
ELEVATION DIFFERENCE(FEET) = 0.10
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.320
WARNING: THE MINIMUM OVERLAND FLOW SLOPE, 0.5%, IS USED IN TC CALCULATION!
Page 1
CQTP10.RES
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.851
SUBAREA RUNOFF(CFS) = 0.05
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.05
END OF RATIONAL METHOD ANALYSIS
Page 2
0.05
6.32
-• .. ---..
• ..
------.. -..
---..
---..
----------
..
..
..
..
..
..
..
..
..
..
..
..
•
•
...
• ..
-
• ..
•
•
•
•
-
CQTQlO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 330 CHINQUAPIN AVE
**************************
* * AREA Q
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTQ10.DAT
TIME/DATE OF STUDY: 13:29 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL 11C11 -VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.30 TO NODE 7.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT= .8400
SOIL CLASSIFICATION IS 11B11
S.C.S. CURVE NUMBER (AMC II)= 94
INITIAL SUBAREA FLOW-LENGTH(FEET) = 65.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 46.30
ELEVATION DIFFERENCE(FEET) = 2.95
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.279
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTQ10.RES
IS BASED ON Tc= 5-MINUTE.
0.08
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.08
END OF RATIONAL METHOD ANALYSIS
Page 2
0.08
2.28
•
•
•
•
•
•
• ..
•
•
• ..
..
..
..
..
• ..
--.. ..
-..
-
• ..
• -
• -..
-
• .. .. ..
•
-------------
-
---
---------------.. -
CQTR10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE
* AREA R
* 10 YEAR RECURRENCE DESIGN STORM
**************************************************************************
FILE NAME: CQTR10.DAT
TIME/DATE OF STUDY: 13:30 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
* * *
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 8.10 TO NODE 8.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
GENERAL COMMERCIAL RUNOFF COEFFICIENT= .8000
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 92
INITIAL SUBAREA FLOW-LENGTH(FEET) = 41.00
UPSTREAM ELEVATION(FEET) = 48.50
DOWNSTREAM ELEVATION(FEET) = 46.90
ELEVATION DIFFERENCE(FEET) = 1.60
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.196
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
CQTR10.RES
IS BASED ON TC= 5-MINUTE.
0.07
0.02 TOTAL RUNOFF(CFS) =
=======
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
2.20
-----0.07 -
-----
---------------
---
----
-------
-
• --..
•
----..
.. ..
---..
-
-
.. -.. -..
CQTS10.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
*AREAS *
* 10 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTS10.DAT
TIME/DATE OF STUDY: 13:31 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES)= 1.700
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 1.00
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== ======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 8.30 TO NODE 8.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
STREETS & ROADS (CURBS/STORM DRAINS) RUNOFF COEFFICIENT= .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 98
INITIAL SUBAREA FLOW-LENGTH(FEET) = 61.00
UPSTREAM ELEVATION(FEET) = 48.05
DOWNSTREAM ELEVATION(FEET) = 44.50
ELEVATION DIFFERENCE(FEET) = 3.55
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 1.798
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.479
Page 1
-'i'-
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTS10.RES
IS BASED ON TC= 5-MINUTE.
0.12
0.03 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.12
END OF RATIONAL METHOD ANALYSIS
Page 2
0.12
1.80
------
-------..
-..
--------------------
---------..
-
• -..
-..
.. ..
-..
•
• -
• ---
• -
• -• .. -..
• --
CJE
POST-DEVELOPMENT
100-YEAR DESIGN STORM
AES CALCULATION REPORTS
-
...
..
..
...
.. ..
•
•
..
41
..
..
• ..
..
•
...
•
..
•
•
•
•
CQTA100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA A 100 YEAR RECURRENCE DESIGN STORM *
* * **************************************************************************
FILE NAME: CQTA100.DAT
TIME/DATE OF STUDY: 10:53 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL C.RITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2.9 DU/AC OR LESS) RUNOFF COEFFICIENT= .4100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 70
INITIAL SUBAREA FLOW-LENGTH(FEET) = 52.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 50.76
ELEVATION DIFFERENCE(FEET) = 0.24
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 11.065
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTA100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 50.00
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.946
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) = 0.03
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
=========
11.06
• -
•
•
•
• -
• -
• -..
-
• -..
-
-...
---
• -
• -• . , -----
---
--
---...
•
•
.. ..
---..
-
-..
..
-
• -..
CQTB100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA B *
* 100 YEAR RECURRENCE DESIGN STORM * **************************************************************************
FILE NAME: CQTB100.DAT
TIME/DATE OF STUDY: 10:57 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL 11C11-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
=== -----======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.30 TO NODE 1.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 62.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 49.95
ELEVATION DIFFERENCE(FEET) = 1.05
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 5.113
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.493
Page 1
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
===
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTB100.RES
0.09 0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.09
END OF RATIONAL METHOD ANALYSIS
Page 2
0.09
5.11
-------.. ---
-
-
-
-----..
-
---
-
------
--
..
-----
•
..
.. ..
..
..
------.. ---.. ---
CQTC100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 300 CHINQUAPIN AVE
* AREA C
* 100 YEAR RECURRENCE DESIGN STORM
**************************
* * * **************************************************************************
FILE NAME: CQTC100.DAT
TIME/DATE OF STUDY: 11:00 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1. 50 TO NODE 1.60 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 47.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 50.10
ELEVATION DIFFERENCE(FEET) = 0.90
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.279
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
CQTC100.RES
IS BASED ON Tc= 5-MINUTE.
0.10
0.02 TOTAL RUNOFF(CFS) =
================= END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.10
END OF RATIONAl METHOD ANALYSIS
Page 2
0.10
3.28
--------I ----------------_,
-------------I
•
CQTD100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 300 CHINQUAPIN AVE *
* AREA D *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTD100.DAT
TIME/DATE OF STUDY: 11:02 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.50 TO NODE 2.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 54.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 50.76
ELEVATION DIFFERENCE(FEET) = 0.24
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.895
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTD100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 50.00
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.354
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
.. ..
..
..
..
TC CALCULATION! ..
0.07 •
..
6.90 ..
•
..
•
.
"'
..
•
•
..
-
--
---
•
•
-..
-
..
• ---..
-,.
-..
-.. .. ..
--
CQTE100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA E *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTE100.DAT
TIME/DATE OF STUDY: 11:04 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.30 TO NODE 2.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 65.00
UPSTREAM ELEVATION(FEET) = 51.00
DOWNSTREAM ELEVATION(FEET) = 49.60
ELEVATION DIFFERENCE(FEET) = 1.40
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.708
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTE100.RES
IS BASED ON TC= 5-MINUTE.
0.10
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.10
END OF RATIONAL METHOD ANALYSIS
Page 2
0.10
3.71
-----.. -------------------_,
--.,
---------•
-
----
-
-..
..
..
• ..
..
..
..
..
..
..
..
..
..
..
"
CQTF100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA F *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTF100.DAT
TIME/DATE OF STUDY: 11:05 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL 11C11 -VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) ====== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.10 TO NODE 3.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT= .5100
SOIL CLASSIFICATION IS 11 B11
S.C.S. CURVE NUMBER (AMC II)= 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 77.00
UPSTREAM ELEVATION(FEET) = 50.15
DOWNSTREAM ELEVATION(FEET) = 49.00
ELEVATION DIFFERENCE(FEET) = 1.15
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.906
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTF100. RES
THE MAXIMUM OVERLAND FLOW LENGTH= 72.40
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.902
SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.04 TOTAL RUNOFF(CFS) = 0.10
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.10
END OF RATIONAL METHOD ANALYSIS
Page 2
7.91
-
---
---..
-..
-..
-..
-
-..
.. ..
-..
-.. ..
..
-...
-..
..
..
..
..
..
"
--... ..
---..
-..
• -
•
• -
--..
..
--...
•
• .. -..
CQTG100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA G *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTG100.DAT
TIME/DATE OF STUDY: 11:07 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE/ SIDE/ WAY (FT) (FT) (FT) (FT) (n) ====== ======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.30 TO NODE 3.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (10.9 DU/AC OR LESS) RUNOFF COEFFICIENT= .5400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 78
INITIAL SUBAREA FLOW-LENGTH(FEET) = 83.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 48.79
ELEVATION DIFFERENCE(FEET) = 1.71
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.112
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTG100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 80.60
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.248
SUBAREA RUNOFF(CFS) = 0.11
TOTAL AREA(ACRES) = 0.04 TOTAL RUNOFF(CFS) = 0.11
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.11
END OF RATIONAL METHOD ANALYSIS
Page 2
7 .11
---------------------------------
---..
--...
-----..
...
• ..
•
..
-
-
--..
---..
-
-..
--
CQTH100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA H *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTH100.DAT
TIME/DATE OF STUDY: 11:09 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 3.50 TO NODE 3.60 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT= .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 68
INITIAL SUBAREA FLOW-LENGTH(FEET) = 100.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 48.59
ELEVATION DIFFERENCE(FEET) = 1.91
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 9.554
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTH100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 83.65
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN TC CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.338
SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.06 TOTAL RUNOFF(CFS) = 0.10
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.1 TC(MIN.) =
0.10
END OF RATIONAL METHOD ANALYSIS
Page 2
9.55
------------------------
----
-------
---
-..
----.. ..
•
• -
• -..
•
.. ..
---
-
.. ..
--
-..
CQTI100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA I *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTI100.DAT
TIME/DATE OF STUDY: 11:11 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL 11C11-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 4.10 TO NODE 4.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 22.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 50.30
ELEVATION DIFFERENCE(FEET) = 0.20
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.748
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTI100.RES
IS BASED ON Tc= 5-MINUTE.
0.09
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.09
END OF RATIONAL METHOD ANALYSIS
Page 2
0.09
3.75
-.,
----., --.,
--., ..
---..
-----..
--------------
---
--
--..
-
..
---
---..
------
---
..
CQTJ100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA J *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTJ100.DAT
TIME/DATE OF STUDY: 11:13 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----=== -----======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 4.30 TO NODE 4.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT= .5100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.00
UPSTREAM ELEVATION(FEET) = 50.50
DOWNSTREAM ELEVATION(FEET) = 49.89
ELEVATION DIFFERENCE(FEET) = 0.61
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.845
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
------------♦·-·---
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTJ 100. RES
IS BASED ON TC= 5-MINUTE.
0.03
0.01 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
4.85
-----0.03 --------------• ---.,
--------------
---..
-----
..
--
..
--
• ..
... ..
---
----..
..
-
CQTK100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA K *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTK100.DAT
TIME/DATE OF STUDY: 11:15 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== ======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.10 TO NODE 4.50 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT= .5100
SOIL CLASSIFICATION IS 11B11
S.C.S. CURVE NUMBER (AMC II)= 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.00
ELEVATION DIFFERENCE(FEET) = 0.25
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.523
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.549
Page 1
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTK100.RES
0.03
0.01 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
6. 52
-
---0.03
-
----
----------
---
-
--------
---
-----
-..
•
•
-
--
• -
• ---.. .. -.. .. ..
• -
...
CQTL100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 330 CHINQUAPIN AVE
*AREAL
* 100 YEAR RECURRENCE DESIGN STORM
**************************
* * * **************************************************************************
FILE NAME: CQTL100.DAT
TIME/DATE OF STUDY: 11:17 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "("-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.10 TO NODE 5.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT= .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 80
INITIAL SUBAREA FLOW-LENGTH(FEET) = 97.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 48.40
ELEVATION DIFFERENCE(FEET) = 0.85
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.657
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
CQTL100.RES
THE MAXIMUM OVERLAND FLOW LENGTH= 61.29
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.004
SUBAREA RUNOFF(CFS) = 0.15
TOTAL AREA(ACRES) = 0.05 TOTAL RUNOFF(CFS) = 0.15
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0 . 1 TC (MIN • ) =
0.15
END OF RATIONAL METHOD ANALYSIS
Page 2
7.66
-
---
-------..
-..
-------
-
------------
-
-..
-...
•
• -
-
-..
-..
-..
•
• ..
•
.. --
-..
•
..
..
•
CQTM100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA M *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTM100.DAT
TIME/DATE OF STUDY: 11:19 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
-----=== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.30 TO NODE 5.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 49.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 48.30
ELEVATION DIFFERENCE(FEET) = 0.95
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.345
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTM100.RES
IS BASED ON Tc= 5-MINUTE.
0.09
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.09
END OF RATIONAL METHOD ANALYSIS
Page 2
0.09
4.35
•
• ---
• -..
-..
-----
• ---------------.. ,
-_,
----
..
• .. ..
...
•
•
• ..
•
•
•
•
•
•
•
• ..
•
..
--
..
-
..
-..
CQTNlOO.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA N *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTN100.DAT
TIME/DATE OF STUDY: 11:21 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL 11C11-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.30 TO NODE 5.50 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 35.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.00
ELEVATION DIFFERENCE(FEET) = 0.25
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.931
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
CQTN100.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.05
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.05
=========
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.05
END OF RATIONAL METHOD ANALYSIS
Page 2
3.93
-• -
• ---
• ---------..
-..
-----..
-------..
• ---
---..
--..
-
• -..
-
-
•
..
-..
-..
-.. ..
..
..
•
CQT0100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA O *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQT0100.DAT
TIME/DATE OF STUDY: 11:22 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL 11C11 -VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
-----=== -----======= 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.10 TO NODE 6.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT= .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.15
ELEVATION DIFFERENCE(FEET) = 0.10
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.733
WARNING: THE MINIMUM OVERLAND FLOW SLOPE, 0.5%, IS USED IN Tc CALCULATION!
Page 1
CQT0100.RES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.10
END OF RATIONAL METHOD ANALYSIS
Page 2
0.10
4.73
---
-------------
-.. ---..
-----
---
----
------.. -.. ..
•
•
•
•
•
• ..
41
..
..
-
.. .. ..
..
..
... ..
•
CQTP100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA P *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTP100.DAT
TIME/DATE OF STUDY: 11:24 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.30 TO NODE 6.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT= .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 42.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 49.15
ELEVATION DIFFERENCE(FEET) = 0.10
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.320
WARNING: THE MINIMUM OVERLAND FLOW SLOPE, 0.5%, IS USED IN TC CALCULATION!
Page 1
CQTP100. RES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.663
SUBAREA RUNOFF(CFS) = 0.08
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS)
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.08
END OF RATIONAL METHOD ANALYSIS
Page 2
=
6.32
--., --0.08 ----------..
-..
-------..
---..
---..
----
---
-
-
..
-..
11
•
•
•
.. ..
-...
---..
-..
-..
--
CQTQ100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA Q *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTQ100.DAT
TIME/DATE OF STUDY: 11:26 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL 11 C11 -VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) Constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.30 TO NODE 7.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT= .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 94
INITIAL SUBAREA FLOW-LENGTH(FEET) = 65.00
UPSTREAM ELEVATION(FEET) = 49.25
DOWNSTREAM ELEVATION(FEET) = 46.30
ELEVATION DIFFERENCE(FEET) = 2.95
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.279
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
CQTQ100.RES
NOTE: RAINFALL INTENSITY IS BASED ON TC= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.11
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.11
END OF RATIONAL METHOD ANALYSIS
Page 2
0.11
2.28
---------.,
-----..
----------------------
•
• ..
•
..
..
..
" -
..
..
..
..
•
• ..
-..
•
-..
-..
-
• -
• --
CQTR100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
* AREA R *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTR100.DAT
TIME/DATE OF STUDY: 11:28 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE/ SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== -----===
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 8.10 TO NODE 8.20 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
GENERAL COMMERCIAL RUNOFF COEFFICIENT= .8000
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 92
INITIAL SUBAREA FLOW-LENGTH(FEET) = 41.00
UPSTREAM ELEVATION(FEET) = 48.50
DOWNSTREAM ELEVATION(FEET) = 46.90
ELEVATION DIFFERENCE(FEET) = 1.60
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.196
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
NOTE: RAINFALL INTENSITY
SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
CQTR100.RES
IS BASED ON Tc= 5-MINUTE.
0.11
0.02 TOTAL RUNOFF(CFS) =
0.0 TC(MIN.) =
0.11
END OF RATIONAL METHOD ANALYSIS
Page 2
0.11
2.20
•
• ---..
-
• -
• ---..
---
• -
-------
-----
.. ---
-
-----...
---
-
-...
---
---
..
---
-..
-..
-.. .. -
CQTS100.RES
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY**************************
* 330 CHINQUAPIN AVE *
*AREAS *
* 100 YEAR RECURRENCE DESIGN STORM *
**************************************************************************
FILE NAME: CQTS100.DAT
TIME/DATE OF STUDY: 11:30 07/30/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES)= 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE= 0.90
SAN DIEGO HYDROLOGY MANUAL "c"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER-DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF-CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN-/ OUT-/PARK-HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n)
====== ====== -----=== 1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
1. Relative Flow-Depth= 1.00 FEET
as (Maximum Allowable Street Flow Depth) -(Top-of-curb)
2. (Depth)*(Velocity) constraint= 10.0 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 8.30 TO NODE 8.40 IS CODE= 21
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
STREETS & ROADS (CURBS/STORM DRAINS) RUNOFF COEFFICIENT= .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II)= 98
INITIAL SUBAREA FLOW-LENGTH(FEET) = 61.00
UPSTREAM ELEVATION(FEET) = 48.05
DOWNSTREAM ELEVATION(FEET) = 44.50
ELEVATION DIFFERENCE(FEET) = 3.55
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 1.798
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
CQTS100.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc= 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.17
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) =
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) =
PEAK FLOW RATE(CFS) =
0.0 TC(MIN.) =
0.17
END OF RATIONAL METHOD ANALYSIS
Page 2
0.17
1.80
-----
--------
-
• -----------
--------
-
• -
• -
• -----
• -..
.. ..
-
• -
•
•
•
•
•
•
•
• ..
-..
•
• -
• -
•
-
•
CJE
APPENDIXC
ISOPLUVIAL MAPS
Page Left Intentionally Blank
CJE
-------
-----• -
•
• ..
•
-
-• ..
•
•
• -
.. --..
..
ffi ---+ ..J.. f.tl~
r~-1-1
; I.'
IT
-
=t
H-+-++ '.1;::,:-I.1L I ! I I ~· ....... 'I FfT ;=-lff ::u:rrl I -I I I I _I I__ .L_-::::_TJTn I I I , __ LUtt=t7TCTTT" ~P-:+-f LJ ,, '-'-i+lH-: .. .L 11 q~ --WJ-t' ~ _ ---l-+ ._,._ .. w"-1 11 1 ,·n , 1_;_.:-_i-r-11 ,-, H-~ .~I LL· .. --nTTTT ++++ t n " , · • . -t 1 , -LW ~ •-+--•H--•'--i-+--'-+-•--++ ... "-H-' 1 1 , 1 1 _LI'> , -; , . . , 1 ---H-f---~ .= -~ -~-f--H 1+ :t ~ . . I I '+++-~+-E+-+-+--1-+ W.-_j_ -1--!_1 I Tffh·H,t· i --rl . q, --I '+f---4
I I t--1-1 --u ~+ •--l-l--j---l-· :-I 1 1 I I __;....;.++--L-+ . ..,_ . ~---
/(:pia,,~ · · ·--++--ti -L --H--H+ · --.-;-1-1 ; , : ·H·' r-H-1+-H+r-ri-+ --t -H+ .................... --'...... '
II '~ .. -~ ! I i.. .. ·. t ! 1---I I 1-l ! i -I I I I
, : 1 . . . 7 l.•~-,,-,:"'"'1;.1---1 , , 1 1 ,. ----j---c--l-_ , -rr 1 _LLL _ 1 1 •+u 1 1 \.L.Li..l • --L--1-+..,.__,'--1--_.__,.L;,,,..I,!, _ 1 1 ~ , , 1~~1:, .,,· ,..L , , , 1 1 , i-Tr , 1 T77TTJ_;.J.J
I r '. 1: ,. [L_ -e.__ .·1 Tt~lv ~l1-:U1t;-etJfl:,_ , ! ; 1 ; , T!, I i I I I J_j t++ j., • H:." .... • -e-•··.__ --· .• .. • . • • • :___ .u ·· ·, .··,. A ?,~·; . ,_JJ'T•-.. ··•·. i,;.,.1 r•. , •••• ,;•.;•-l"'t.:111 ·~,. , .
I I /\!•. ··::t.-, ·' I --: --17··; .. J •••••• ·,.,N■ I '• . ·.-. 1•}, -w .. :f _I.J • • : l rrm•
. I I I ~l~~ .;· . ,. l• . ·-h -.... -.. ~-: ! .... ,,-l' : I ; ·, ·, ,· -.~9--i. I: 't I .. · : ; .. .•,, ;;;· -. . ' ' ', I 1 ·., · Y:•. I·.~ ': I 1 •l'l J•.L.J•'.LI. •, -+--H 1 1 ~ ·~· ·' -·,.. ._";. •.,_ •Ii i I'-.,,.•, -•••• , 1: : l ., e--1\r:-lc.1J1-r-,.-1--
1 I f.."' • _ • _ ;. : ~-' •• •. • '• ·,, ,\ , } 1 • •. ,•., I: , I -J -i: I ~ i.,-,.~ -·. •.•., \ ,(·I .~ · . .' lJ I(•, ·-1., • ..... '• \,:, .:, I , "T• ! 1 11 ■
County of San Diego
Hydrology Manual
• . .
)<l : I><• I . I • /,1-: : .. , •• _,.•,!\\ '\: --r ~I 7'! I 1 11 ■
"i\:. ·:,. • L.. -""' -r I•,', I, .,. ,· 1 \. ~ ! :: .. [ ! ! f: I l ! 11 I . . . . ~ ,. .' 1 ~ I •• ,. I ' . • -· • ", • : ·. i.._ · ··'-' I 1:.. ,,1,, -~--· II I I I 11 11 I l,'--•L'I v1f JI .• j · :1-., J<•'!. • •• •.•• , , I •, 3t~
• 11
Rainfall Isopluvials
i I I I ! I I II , r--1'.1 Y• '"" .r 1 , I\ ', : • · .C~ . • ... 1,..-'-'. 1, , '• '•, I • •• l_ I II I
·-• II !I '.····;-··~. ~..:.i--:rs -.-':~· .... , I ··1 .1·•·111 1
~:,.l\E~~~J'l--l:'l'!.,.µl--+++-+H1,Hc-kH~:i!l---1---1+-1---++-1---1'-1--1---1-1-J~:*·~-~--i·,1. , I , I J:, .. o. .• I ' •, "!'•, · 1,· ·, I I 'h·-H+t ·H-
.,,. l). r,.~ •• -· ·•l '. I. '. • ~ ,f • • •• ·::,.-~-~ I_._!,_! : H+I 1..Jr..U.1 ~~ RJ vi •
J k. ·H '•~· .. . ·, ..
10 Year Rainfall Event--6 Hours
h.LJU .. , ... ~--. -'r I I'''' I'-, .......... , .•• ,; .• ; I _•_ .. ; ..... r. I,., 1:1 J' '" tt-t:ttjl-.ff't.-H+f ·J Q_Jl"'M-~~Ll l ld::l _d"i"i•-l .,_
i I I -•.J.U .. ,f
lsopluvial (Inches)
?"l'i. "" -L. -;. : 7-;· ff, . IC'\ I\._ . ,.., ' I i I --1 11 -~ • Ir!' r fr, . .f,•·'·• ,.._l~,~ur:-J .l •·,•-• Erl Ii I ' I !. ,i : Ill'\ ,J ,r ~ ,"' l•:1:•1.1v '_[ ·,·• '1 ;-_0,-l!I
I I I I ' I I i .. ,,. --\. Ii r;; : ' :,: '. I • ,_[ ~ . '•"Pl-.;!-I i ' .
. 1 ; _ , 1 , , ; ---... --,-.. 8-J. ,.,
1
~\. "" _. .. lf -1r I I +· ·· · , : ••.\.1;'. ~H++.:4-:-m+++++• ttn· _[ ' I I [..( I ..,.. •. • r;; •, . I 1,1•,!I . .. 1! i• ...... J _J.1 .1 I I ' I ' ,--,• · ; ' >--• . /I ' • I · ••. , I: •□-~,-' ' ',I _' \ . • f-+
TT
0
!/'t ': i "'' J I • ~ •. :, :1 •·'·!·; 1 c'J\• -~ • •• ~r· _ I'' i I . u ' • ',: \J tF.-~ ,--_D ,. '.. • .P • ~ ,;;t ,I I lLLLU I ,-, n e1 " .• , • : •• •: •~_;u\ 7~ • • I ~J I ui;u+,, •·: •.i· ,: • • ,\1•,,._j :J 1 ··-'h 1
. ·,, I -,, '":." ,-~T ;I :i···. •i ·L,: 1,1· ·[fiiifi·. . : ' -.;--+-~,-+-f+i·H 11--, , -~•-1 , • .,.. ·•, .. -1 "' 1. :r 1 •. .-,· •• . •:.1 -.•·i , Iu •. ••• -~. •
1
•• , , 1--'1 i
+t-' ' ' ' ,, ' ' , K c ' , ', _. , , ,_ . " , . ' \LU:<,. ' , , • ' '• :: "i1$, \,o--"' ' -t _J , , 1-'i I
1
"• ·;. •• -t..1~ 1--~l--'7 ·-:u··.l t:-_iJ-I l 1 ', •·1,.,J • •' ~ / •1• P i I . ' • . ' " ■u--. ~ ,1 • • • • • ' • " ·6--.. ..... .. ·. ! ' -.. l ! I I _j_ I , , ' 'i ---!-J ! ' I I 0-;t J I I ->·. "•~••' ! '1---+--mrn"f.\ • 1+.: il L1 N ·-i • ' I I I I ' I . I : ' I I r, iL" ... l/J .-c,,,_ ~ u ; . :i il ,. J . -. ' I , . I Ll++--H--,1 •_l1jl ! lj, J'!,,.Jl,,
1~ = 1.1-3
~1: llllllllllllllllllflffl"I .........
::::: ! l-'-+--H-+-1--i---l--1---l----t---,-+-,--+-t--++-t-LH-++UF=-4--'ll( i,lio;P,'::;:c-l,'!~+· L:~~~~'I, --+~~-~~1''-~:~';_::::.'.·.:.;~~~.:i:,_~~:i:c--1;;~~;t':J~~J~:::~~--,;.~'i~1=-t1!'!!,e,,,j~~-l-ci--1---t-t:+ __,::!=J-~ti~~t-L\i.-111+-_+,·'-+--HI----D--P-W------~·:--------1
R+ ~ --, , ~l~itTJ:tifH+if.~:ffl±-i:-+'+-4--+.H-+-.'14--f-'.~H~~d±tttt~-Nc+.tH--'rf *GIS SanGIS :q:::p::j 1~• I [ __ .'ru. ·M--t-~ --t--+ -__, ....,_f-_ ,--;_ +-,... ++ --=-~=--We Ha,c ~n Diogo Co.crcd!
-~-:-, +.J... ' 1· ll~!~~~EEtIT ~fe$~l~~iE=t=E61H1!~iE=fH N na ..... •~'N!MlUTWNIWn'YCWl#IOC),~EXPfl:EU ·mJ.._ 7!-+-_J._ I , ~ + :~~~~~~~Nl'WfflU , · ~ · · tial~~tHi~1tn=1:~1tntt~i~~ ~-'--!--+ ..... .;. • ~e..GaMl'llltlll"'""""-±1!. L..L -f-+i : T~ -i-; 1-1 ·U ---'---La.-l--· 1 • · ~-7' · -..... _, .... ~IQ'fl .. lW&MQ.....,_ :t--....1~1 t'~,·J~1t: -r--TT i=.W {-. I I -,-I-';-: ' . ~ Ii l --. -m~ :r B :::.=:.:=::=.=--:.-.. _ 2_ ' ; 1 ; : I / , ' I ' 0 : ' : :-, t-r+-'fi1 • ' ! s--;-t ,-r ! ' , -111--t-t--l-__ ., ___ _
,-. ---t-:--q ~-+-l..!7 11-'t-I I I I ' '11 I ' I ' • I 'I! . ' .. I 2•30•:+· s ' I -r--+ 1-11 I +-c "-•-,--l---L, · Lµ · .L!....,..-~---~-+ 1-·--+-+.:.~-~ ~; . .µ +11>-'--i--,-+L,. ,_ ~-'-f-3 O 3 Miles . ~+i ➔ M-1 ~.c._L}-.· -11 ---l: t -~----: '' ;-t•J,: I I~~-!.' t -: i7b i i 1--: i I +';~ 'U,+~-r~~ ! i j ~+-L-~. t-+ I Ir~~;-~i t l...j. -
_j___J_+_;~ __ cl..! I L_L.~_;_:.LL_l '.-,r--,~.__:.:-:.:___~r-"'!---i--j--;--f1 ~'-1 ~-:_r::·:il rr----:e I .: _, _!_:+.,....,~,=-1-hrlf i H·tH -
~+l+Fm=Rttti}~tf!= P+l+P=f~: (--1
I I -! -I I
~-~~,-,-,-,,F~,,.-,-.,·,,--r,-,-,-,--···fTT~ -,r T"","" I I I I l l I I
,-1~·, ,_T l I ·' I '-1:.u'l-l-l-~~--J ,_:_;_(_!_'_m·-+tTrt+-+ I I -I I I I I! : I_ >->-+-~-,-1i. '-;--, r+-· -'I' 7 I . j r --T-t-f-J 7 r •--I I I ~ I . t-+-!..7 t--t--H-~-I iJ;-ii . , .. ' • ' ,-=Ri+++ ••i-. ._j_L !_ ' I i i+H--~, I I I = . I I ; : I I . H ~-I I --1--1-' I . -•-'-+·-+ H-+-t-I I ' I I I I
f--<--t
1--
.. LU -++ T 1 ·+ -l-,....;. ...... 1-+-+-t 1-+-Hl+-H-~-+--,·+-1-++~-,-, ; i ; ' -t-· I I 1 -t-t.-,r-_ , .. -• "~' --1-I I . I ' j -L..,-.' ... +-H+-:-t+H-ti-I : i-
·-• 1vr r~ " . I _I\: -+-1-1-i-++f-+-H-f--H+H-~ ·-+-· t I ; I • · ·7 1 I ! I ~~·
I . I I' I"{ 1J +· ;/ -~~ f'.l--+-11-++-!-+-+-+-+-r+-1-i· ,--+-1-1-~f-++-!-t-t-+-H~l ! : 1 ' , i ! I I ' f-t-+t-1
'T f:' ' _rv __ ;:_. . .'.ill~-:" ' ' -e,..,_, ' er" . .. ..... ' .-:: ·, .. ' . t:ti_fi j LI t it 1··:;(;!-~~-·o Cd 1iJ ! -~. .• .. 11",-~ .•. 't"-r"''
. I I I tJ -• ,: ;, • .,/!,t•··-vrr ;-.,.y '.1: . ~ \ 'I , · ;,, .. •. . ! l '!S) ~ -,~e",_'. '
I t~·. _• ••.• ·1 I i!l :":••... •• • \'•1..J,._: ,_1_1 1 '• ..... :'
I I ~ ;,. ~• •!·• I : • •,c •, ,: • ,', •, •.-, )'l_-· I .. I -f+-l-1-
1 I I I I I , / : I ' ~. --•. • • . c,u• . "' . .. ,., ' . 'I I ' • . •·+++-++-H-J-+-11 I ' ~-.. ', . ' '• '·• ' · I 1, U " 11 11 t i •~-1--' ', .1.,11·11-:trt.' I 1 ... • .•:,. ,·; •>, •• ''', :, .• ·11' ,,1,;.•1 1 11 1 1 1
I-' · · -R ,+:iL-l-41~+-H+..Pi:-:,wbP'!t-~H~MT1 ·, •I 1 ·• ;1, • l ' ·· ·, -; N 1 1 1,, , ■ i I I ,•.· I 1, . ' •. • . . ,:, . I --+ ...... '';' : • \ • 'i I •. l\ I ' I
. '
j_
.j.. +J. I -~ .,, ·c.. ·• , •; .. ·1·:' -~-1·,. . ,,,;,., .! ~ II';.
~·-~ c1 Lio.-,.···;.J ,._ ·-. . i.,+·•~ ·rn 7 •,:77777$t:tT!JII
I,'... ,.,. I t . i u i=t'•' ~w .. f, -."'; •' . :" ... ~ ~h,+ . l . r·1·+·H--L . , ' --l--l--W-1-1 "' 1 I ,.,1;:-1-• I . .. • I I I T ' ! t I I I ' i i I I i ! I I 1\1\',J ,Y• ' ' . 1 ' I ·f='f~f-. l'i · .. · \ , ' ' '•·, .' ,...-. ,'.1_,
1 1 1 111,,, 1, 1 1 1 11 •.u.1:;::-;:::: ~~~~ 1
··: 1 •.• CT •· . · :'··" ••.. · ·• 't+H-J-Jii"fl=f+l
;.-, l,. ; .,.,. J ! ... :: .":: ... " • .. . . -~, .. 1-1••1 1.J •• -t~i , i • ,. '
L:J:..l . L
t;;i
~!, 1-:J__J_l l
j 1··► • ,~
1 i ~OT='' I I I I I """" , , , ·•, ', •• , \ '. ,. .. f..l. I I r·l.l ./-++---
~:, 11, i •"•¥8.f-+ . •, .. ··-·· ,., ,. ffi! I +-
• J "~-. ~, •' •. _.( ~ ' .'. .: :·. ·-'•,--1.:••· .~ .. J . • • I ·• ·,· tf..+-l
i . I : "" • _... .. • r; tP" 'f-1" Tf-1~~~\,-ftcittt-i+t-H I : ! ' II • r-. . I 7 ' r-I "I f-f-+-fi+H't+-J;., . . -1, ·• IX • I .:i , !,< • I~_!-j ~ :1-.-Ui;,,l-..++-;t-Vifc· ~--HH-lf-irr-ti·.-: ., ,,1 ·t .j ,',II •1·i;;:.~-t±:l ' ±l"i ..
11 U, ~ qui '''ifll-' ' ' -I H
'!' IJ. i..iftr;,:, -1 I f -~ .,_j I IJ!I.....U...jl -J:QflJ_ . .,,_,k_,, • r ~ ·.......!-l!'.. • , / I
·r.T i'J LI , ~,;...+' rq;-_T YI_TT: ·ls .,,,~-.t5.2'1 i 'i\ I n .1 , if-.! I '+t:J'*~'-l+ LJ f . l , .. "' Cd_L'i,. 17':'T,t,, ,I' : -!: I \· '.:;, t~ •
11 111 11 [1 ' r1 n dEi -'r,,, ,._,, ... , ., :: i !:''1 'I\ . --11~TrT1 1 ;,; 1=1 1
· ' I ,1 . _1!!'11 .•·v _· ,,1, i , •~ ··, ,. 1 1x t 1 1 lc:bl
I i ! 1-I I I ' I >-·-,. r/ , • .' •• • I i'• ' · ':l:t'I : \ .:: .J .. U,4•·n I -n_
. I I I I _l y I I .I • ., .. •• J -H'++-f•+ !• "\ • '-(• IT-' : I ."'I T I I I I !:!!_! ' ! 1 t ; ~ ;,.. ,•. ·.• ·.1·. r-.. ;. ·: · I \,' , 'I • ·r-.•.. ". \ I , !
• • I • _, I i :-. I 'rw :1 •~-•• ' __ ,·1.•:,.1'..'.l~ ••~.!L ••-l-11 i ' I ..., n-. I I I . j .· ' I I/ " r--r .. --~ !I I . "." T n ::F: ,. . ···r •-I \J I I I ... , I IH-i-,: I i' +i-.U-/-. • ~ ~ --• • • ..-•,.... ·n-n::_1, ',•cl '.!'. ;:-,. . -i\..l t t :Pl t 1 i'!, _., !i.1 •I -r ,_, Ju I ··.r-1 i ..... ·t;lm•--•,, ..... ,.1·, I\ 'I 7' ~ lu-1 1 r , , , ++-J-~~t-1 , , --l+H--Pi:ttt;;il:h , --L 1-, CA" . 1 , r, •T· :· L •11T e,-~ , -'··· , = , 1 , , LH-' I ' I I ! : I . '·, I .• . -. , .• ' I . I TTVt!i rt-'. -:-" ... , I r: I f m-r
·••1-~--!-.L~.'t:r-H--+ --H=-H--1
County of San Diego
Hydrology Manual
• .
Rainfall Isopluvials
10 Year Rainfall Event -24 Hours
lsopluvlal (Incites)
@;:3.o''l
I
I
I
1
..j I • I I • • .·) '"' .i.-• ·'' r, .•, .• fr J<f ., 1'1·-k-l:J·' _Ul_l: I. 'i .. I 1.ULftm# H-s2•(.I I ' J ..1 ' • ' ' ..,.. •' •-··-' • •• •• il I i T 1 · 1 I ,-,0ITTl:..,,, ',! I -, 'i · f-L , · • r-1 1 1 _LI _t l_l ! J_ 1 t [ ·;.;, ,;., I , 'l • .l'?· ,•,!"._w j "1··'·· •i-..J .f·t 11 f !l ]', •, I I:,-.:! 24 . t:J+H+· I . r. ·tt-_...i..l_J_ I. . ! -1:.d, ·.,. :'!t''-t-, ·"1 1 ! 1 ·'•·R. ;s!-· ·r-~~n ·i-:,· !TT ' r. !•,\ ,·r.r .--r-.,. _________________ ,
L " I ' • ' ',<Tm• t-1 T I ,?fl,. i i i •a .,Pit_' ,T I' .:J. t--""11"'' J,·:· • ,_;_'O· ""·, .... ,' ,-, ,-~ -;+-c-1'•' I-t --!-,;_+.... •--~ +.. + · •· '' • . ~' · •• • 1 .,__1_ • ' 'ol I .. -+.:...t..;t+ h+t-. I J . -. +-4.j..L x.<,-"' ' ' • ;-. ,'th. -1+.H~ .L_~-I "' . T ®~~&l. .. I • 1: I I ~-' 8?+ DPW 41"--
'. ·~-· 'I '',._ ,_,,__,__,_..,.=J . ....1-I'_,,.? I U,i•:I : ··,. ''• C" .• Fry,-~· t. icW ' .... , ;....J.•:,,,J. .. , ... ~ ··l ··t IJ ! ! ~++W-· ---~ IB:ffir~'ttt± liLlJL~ rt-Jtffi~g· · = . 4 J;t;a c,, N . • -f±tr4:l'n•+ Jtfil· ,-, , 'ffl-"-t-r,➔ ,-f ,,t _QJ:§ ~i!e~!§ .. 'I I I J r ' • ' 'i ;-. ' rr I I i'-l: ;(-, I ··-~ l ,·•' .--1-~11 r~l Ll.J. ·.:pr:-,-·,..1---.--·!7 t-t·. r· ~ IR#t-m-•-mm• ·s·-f .. +---+1 .. ~·· ' -• ~ -.. ~;_; -;-::.1-+f:q· It .~ 7 Ti:•~7_1'-!J i:1~...:.-= -1-~:llil 11 ! _.,..:_.\ __ I I-, I 1--1 '_j_ ---. ego r . ! ' ·r +--l-·r·•7' +w-J -H ' -f.;.. ",, ~ • .!:ii.!~· ,'..Cr.r-·:_u ·~~-.,!.::}c .,. I I ,.._ Ji r I I : ..: -44-i . TT"~. l+t.-L J li±' ~ :H'::1 J_ N --•--w......,.,.,. ..... ....,_.,THI ........ ' LL.if-..J....l...L..! J , · 1 "+ '++-l-..t,e, • ,.-1, c:;,jj_ : ", · • ' ~" , , 1 , · , +· 1 1 1 1 1 · 1 ,,......,..,,._ . ..,..,....,..,,._ ____ , 1-1--rr :~-I i /l --_!_[~ __ 1_ _ _'_--~ -~. i .. ~-. '•lli·.~ /-tr: .J_!,l 1,{i_i.,•i II -~-i-r ! I '!: -, 1 i"i'it-t-l-i-:.'1-,11 I fT ,-, I 1 1 1·1-=..i~::.r~==R>flAPMro.l.Nll'IM'aE l i-1 '+ t1:rrn1 : ' lJ.. ~ fff ~; 4--1 7 h~"' Wi .. ~ ' I(,,.., /tj ... ; . I J rr+-1-: m·~--H,rr l~-! H-t+tr 4-1 J I I ' 1~ ......... 12-rrr + ... __ .., ____ h...,.,_ -l.-1-r jj _L T~-,--T;J __ L_:_, ~' _r:-r:1}--rt-t·-~1 ~" -I : I b:r-:t"""'·-r-r-,-,-\·A{-4d"7 ' +-t'-f •t ->i-tit+-r-r1-~++· l ' t, -:--t-r~·l 1 r+-=-""1,...!:'.,~-..-..-,~ .. 1, 411 1 -~---:-t ,r ,H -1-... ,, .. 1 .. -:-· ....... ·r-t -LL ... 1-v,:1,.~Q....!...-r---+--H,-ri-r·•-·----i-+-__Lj__1. t~--J-L1~ .........,~ • ..,,...._..., ,-f-:·TJ e·: ./ 1---h-~-1-·-++.-! 1-1-·t r·I+f 1-+T-f'-1-:-1 ~-, L4-+-t-++H '~TM..l...,...:...l.J l 2 . 1 .. : ~--'.]·., 1 I f ~---~±t. I \ -I..L H i i . ' I I ::=;...-::--, __ _ !-i!-p 1 1 !,' '1 , :; 1
1 ' -~•, 1 '', :• . ~_J_ ,1 ,'•: I 1 1 1 ,:!:'.:::. ,,,1•'i, ,' '!'.,'•,~!,I ' S lft ,-r . -r++ J-i+· ~ l . ~ i ,+,-_: ,-+++; i-~t-,-~-+..,..., . .:.+'.1+±!:i, I ! !c;,+; ......., ........ _L......,-.)_j_[--L;:J,...L+-t f ~-'. ~-. [-,+-J~0-i•1 i I ,...Lj -1r-·1 l J. 'H'-J4-l-... ~' ! . •3 ~-3 0 3 Miles ' ~' . Gt ,.c.......,__· . ' j-, LJ.;I_J_ I ' +' . , ttiho. ' , , ' , . . ' I ! ..;, , ' ti.! ' ' . I"' , I . ! . ; ' ... , ' , ' ' ' 1 , ----,· ~JI T -r,.. I . 1-~-'T --1 -• t-+--,·· -,-~-·:"""' -,,-,--· 1 I . · \ ; ! 1-+---:-! ·, --;...~,~l-4-._. ·-. '-.-• -r-!-·• fo ~---+4-~j I -I ...;_!....,_ __ ;·.......,.._+-. , l. --j { pillj
1-J t ----• s::......J i •---L ! f I j -.,-L , : } I " I , ' ' t • -j , / t • I : ..., l j I 1 1 " / , 1 • I j ! : ; l l I ' 1 ' 1 i · (0 t I j ! ! j ! --! -Li __ Lc..L .t..L'...l. J..L.. ·.i..,.'. t:-~: 'TJ:tl..[J_".fj b ~ ' -P T T f t t·~·,1 ~+i-,-T7"":""l'fl""i t 1 11-:-'.+r;:-,~-:--~-4-!-1; ·: f-;---~1 7 i] I f 1 ••!-
I I J l r I I I r l T T -T I I I I l -' -I' l I T I 1 1 1 1 1 , 1 . ;_..._f++-++l--+-1--rT= -•1-iTH-+-t-1-t-l ~ -~n -1--1-ft+m,-I I U ! . .,--ttt'S ', '• -'-0 ', -TTI ,-, , C[ITT,-'r I I ''
1t-rtt·~-l-f.i,1c11r11t +-1 II; ll ++l_i I l ~,---~,__:f-__ i I I I ' ~ll+t---1-'li ..,1 ,_ hi-H-i::t-i-:t1•11 1 I ll fEE t tit'-. +i-1~~
1
.•, :: . ·:; ; i-Tf -' : I H+1+ •-r· . · I-+l + ·+ H-f, :-+~+i ++·fl ..! r -i-t+: l
1
~: : 1 : :
1
nt :w·' r-~ -l I I , ' ··LL •ir, ' ' " l ' I I --' ' " , ' I I I -; I I ,-+#rr--++ w+-1-
f-
• ~I I:7 r • •••
0
-tc'-, -'TT r , I 1 , • tn-r· tf" · : · , .. t 1 • ,
1
; ; ' • · • '
-.. I I fl ·· ·•: -."-1 I ' • ,t· ~ ·· 1 -~-,-j...j.. I I f-L' ' I I I .
1 1
' i I I ii t' .!.. , , I • • • • a-, , · , -· m •• , ' ' ' T '
-'-" ' -_--·-R -: _,-• T e . _, , , r , • r,~ -" 'ft _r -. , -• -F r " -, ' " ' ".
J
1
[ r c! ':·:·-~ ,. · -~,. " ·· • 7· .-' , " '• ' ·H·Hr+-
1
,+ ;+++-Wi...l=ffi
' 'l'-l 7 1:,-4 , l,¢ ... ,. • -. . '' ' " ' . I " I ' I ':(,._,., r.,T-l:: :: , "• .,, ,--.. ·•~·~:, ,··;. ·.·. •' ,, •u , . 1 L I 1 1"f ' • Tl• ··r, ti ~ I • .... • -11 • • • .. . • '·' • t'•J t L ,, __ ..,, ,rT,·, .. ,.,r,·-, •,' ' "' ., ,•, -·. r<d'li',1111 l 'IH ,,,, " "· ' ' "" -' .. ' -, ,' " . -... ; .... " .. , ' -~I I.I •I "i I • • . . • •. ;•: •• .J.....Ll • I t'. ,.
·r1 ••+j m1••T-~ • j-. -i. ....
i 1r r+++ · · ttittttt~ .
L..LLJ"...1 -~ :--r-
-tt-t+l-+H -
'1"T ~1 :J~T"fTT
County of San Diego
Hydrology Manual
• Rainfall Isopluvia/s •-11 · --1 ··• ,·m· .. : · ~· ' / " . -·, -• ·• ,, I ---I I I I ' I ' ' ' rol .,.,._,:-1< -r , .. _ " " , , , , " ,. , " I I I T I O ,] 7I
'.11_~;1 \I Ii 1· I I .. ,. , .... , ,··1 •• • ,. ·.' !',' ~--'71 '' I I 1
1
II ,·('\..j '.t•,. . • I ,. • •.;,.-• ! , 1···· 1 , II
• 1 ,1•-b;:r '-\ 1.1, ··
1 1
' ' , _ 1 1 1 I, ,-. • • • 7· . .., 1 • . • J..1-,··f• .1., •.. 1fm 1 I
1 1
, i I I I I I 1 I -+
~~
I ' •_/ l, ~ . 100 Year Rainfall Event-6 Hours
1--t-
'~ !i • ··,t-~ ! -~ .,•-r_1 -.,_, .. n I I I I I I I l I
• i;, • ~ • .,.. -, .J...L -1 !"' · :'l'•I I • I I,_ ,__· ,·:c.,ffi·J..:,.I i _, l 1 I I I "'-. l n · I l I •t· ·• · I '•. j
I I I I I 11 II r T • • 1 •f-• • ,· : .,. ! , ,;;; •• •
I I ! I / i""l11 I . -1-.. ..,... i ', 'if ~. --
·•-U
f--
..)_)Ji J J JlJ ! I J I or-,-..-~ -., f•. .. .. Lt•: I
I!,,'! _l ·-• """"'"" I ' •,; I I ~ ·r ~ ...... ,,... •• • ', ~• I ~ I H---t--r-1-+-.J I I ~i-r-rt-r"H-t--tt'tl-'IH<\:l;:lt--1:. '. •~ , . I ! •. , I L' I · •, I I
· ! [' J;I Pl~ r--•.1. I/ • I ', f ; I ~ ! I
L._. ~ _l I v • -·f . :; • · ; , i• I I +-l-+·t--1---t--H-r-HI•-I ' I II ~ ... Fr-.. IC. l ' • I I , . ,, • "" I I :'1"" I I,, ... 1('\ .. . I C i . I ~'.00'--l-+--
l '-t-_ ! ! i' 1 l ! 'r.rl M ',).:,. ; I J\ ; I I = •
i_ I l ! ,-, _J :. .{-,'.' :1··' •, ~ ~ i ; '• ·:· • -• ..... • 1 T-•
I :f . u j 11.. .. Ill l : ~ -•, •• .• I ! : i i -1 I
. I ... .' • I V ...,...,.....,.....,..,..,.,... . '•' .:,;...t· .... , l~r, L I... I
I l j I , I : : •• •, '• -.~. \ ~. ' !7" 1
i '1 • II LJ; .' :, I, ' ; t---_ !.·• ·1• r 1 1 1, . _ , 1, _ ,..;-, • ··f. . , •~ ·H-t-t-t-rH-rrt1'I
I I I I ;;, .... ,• ~ I _,..· 'j' ... , • '• •.• , ·,. I ' 11 • •••• I 4-++. . !-II ,1 n _'\ 1,_· •• •.:, .. -, i; . 1.:-~I---JY . ..[ 1 ., •• J i IJ ••I I , -'-' --:-• , ••• , 1 .. LlJi,.i.
, i ! I J ! I -~ I/ ·, 'T:J'"f • \ , \t • l_l , , •~-': i I ~ ! ' II:.:
. I ! I 1 ~ l:IL. " • i Ji , · , ·, . I ~ ---JH ,-·I. f.r.T"·tt 1..fJ..i.. 1 ' I l~T f--4+ 1
I +-L i j_ .'-W...1.il.; lrl ~H tir'-~"'D l----~ "T)~ "i:f:-r-:--'t-.1 I IJ L I 1'· I
I. I I Ii ' J I I, I TT, M" i 11 I ~ , I,,.· c!,1,'.J "i I 14:·• -'. ]'· .; .. j' ·; :1 i J,, I I • .1 Ll
lsopluvlal (Inches)
rr~ 2,~ ,, l
mm I i I _J I I I i 13,, . i •• ·.I 11! I TiTTTT-. 1 '7 rl; 1"· ':'.III . I Ii I s+-1-J
... ; I-' , ,
1 · I I _ , i / r., I : •: .LLL .:, ~ _I__ ~ ','. • ! ·1 I \ 1 l I I •• .~µ._j ttm~W./....1....l ... ttt' '-'--i--J ! uJ. ' . I ' ~ i I ; .).;~r-i··}; , -.:. ' -:;l · : I .j • • i ! 1 , 1 -+-'ffit--------------------++ 1.W...j..i-.'_-~i i ;T: I iT:"1-~ • t=il·.._:::__7:, ! ::, .a..11£----::-r-T~T ~ ; .. ~:-·'t i_-'--;, i lt~'-•.+-TT .' I t ; ·mt±' i_i ';1_~1 :, JIL ... -r<-" ,-r---:_111 !,...:_J\L :_4-;.,....,.J .. ,·H-._!J:,.;i'_, :TD .. c-1~..1.& --•:, ::-1111 Iii DPW ...-_·; ]: '. !I~-,-·1-1-+++-~: I '~~:? '' -~,U:•1-!---li-JJ·N= '1..:.i..~t-,:; .• 11 1 1:, -~T 'r:---:1-t I' • -.}~NL:. l'·LL-:1 ·-i\l~II---'---. I ----G1S s~anGIS I --,.+-H-. , : t-'---l---'.L' . ~:\. ,... ,. •• r·1 1-:ti. ~_J_ -j: 'v : ~tlq·HLJ :;...,J--~-.. r+P,-' -,~ ~, i I lj;.L+-w.. ~ +;J --!--l-+r++::=~:1. l j_ooil++~J. ( __ _:-··,·_~ •' =-t l'J:J.f:.:r,T ·1R·-_ 7 1,.1;)+·1-:g:_2_~~-:..:.;.;µ •. ;..4 ~;,.-I:. 7+J j~-·, -_.:j\;_ll",;: I H J__i; -=-~=--WeHav<£u,l);'t(UCo,=d! • ~•' 4-r+++ i , 1 : -"---1-1-J I• ! 1 4 ' •••r 'llr:: ': i '' (~ :· '· l'J : t'°1'l-f_: II 'I I I Q · I l 'IU ~--! Lt=;.-'. r-,,J... -+-i-J..,:-~-!... ~tT ttH+++!,· ' . ! i :t'i,/:;_:qr~+---L . .;•-t-·' :,-t .-.... '·~ u i :Ljh I;"" I H+H-f_ l·,·c·. I N ~=·='l=ro_~~=.m.""'l'"' ,__,_ __ 1.._--4 _, -i...r1 + j_++i ++· , .. ··r' l -1 +.l.~-,.t.t: ~ i •• ~~~,. -__ ,.-,:.w..i.i-: 1,1-4-:r: •.x i,_ , t ~; -, +-~-, I • ! .. "7 I : ·~..:.--, + "'_,,..,. .... ,, .. ...,,.,,.... .... ...,.,,,..._ -.lli-, _LL~....! i t -L-L -I : . .J . LJ_rr-,.L 1-r-i--.:-~a.t1., ,.... ' r-:-! ~~ L • -i.~-t,.!.J:_i Y . ~L--L•-•-· t ! ! ,_ . ---t-+-+-' . ' : . ·--1--L, .:--~-,.....LL+-~-: o.,n,ta.a11.M,_,_=twn ..... •Nli•cu • ..,: ...
~
-• 'r r~•TI....LL, ...... 1~ .. I _f L.-....1.' i • I ,~, ... r -· l•I '1 . j . '-1-.! ' 1.1 I • x· lY,.J..JrL ... Q. Li--4+, _ _j_! H·· -.\ t@l I .. I i 1-l~m-' ::::=..::::.: ...... _ _._ .. _ : i 1 1 _4J_1~~i., 1··17, I r-;-TTr--T7"1 .. 1 1 . LLJ. , .. ·7 1 ~-1 ·Cl [ !mti,: ,
1
, 1 i r .J l i-11' t 1 1: I 1~~-·----I """-'......,..,~
L ' •. •. ·t/=1, r-r_:l. _ L.. '--· . .,.-.,..-r1: -r-1..f TTT"-i-1:.r:rrr-:: "ir --; ·~-t--tTrn· 1 • . ~:·-ft· , , u 1 111~ ·mi J.U-,Til. i..Jttt' · . ...;. , J 1 ,_ :::::-.::..":"'~-.:---I: [31,• , r• 1, · , . , 1 111m11 · 17---..--,i 1-r:-,'-t1 Hi·n-t• ,·,t 11_, _ 1 1:, !tt-.,,. ;1•1 ; , 11111T11 11 , .. ,] ,.,..:i--'
' • ' ' ' J ; ! 1-1-· ' ' i . I • I I ill' " ' ' ' . I ! ' ' I ' I ' '.l.J...J. I • • I ; ' . ' ' I ' ! ' . " ' ' ! . ' I ' i ' I ' ' • 32-30 I ' +---, -, t1·-'-t-·' i ' ·-r-g·r'-+----H-t-t-+-LI...:..... r "' . :t 't··+-.....:--.:...,. f-f-ig+-;ift-Li---l--4-;r, ~,-~:-, ,+,-,-~, ! '"T ' . -~+4; I Ii >--~-•-' .... ' 'l ;~; I ·•-j 3 0 3 Miles
1 r-.-i-'--:-1 -tt ~-·•11;~ . t-~+--~ r-~-½-+-t-+Jj:~-: ! I-.-, -~ti~~-! 11 r-:_ __ :_:-~ ~; t«r ~-i~-.l t--:· i l·r•-rf--~J..art-+--t-+-; 1'"1 ' : : : : : ; '1 i r · _ _._,_i '_;_~~~ ~ ~i".J+; ,. -~. ; W -1 .l. i"i •-J-··,-... -=' , ~-• ·'-t--'-+---'---1 ~ 7 ..,J;.., ... L ·····1~ f--.L'-f_l I I i-ft \ f.-·-· ! I ·t I . ! Ir I-[·• C-,--!--+-+-1---+--H--=. I-,-f I '--, •--+--,---~ ~I 1
· .J._-LJ_' ~-' .:.....~J -L . .:f ___ _L...:._ .:_.L..L ~ _ _l_J_j_.:_:_:.. ~ ._--~ L ~ L-'. . l lil...! -~-1 ! I j i__ilI,,,L_L-· 1 : r --1-L-Ll.. ~I J "'L. __ 1 _ l · 1 , · I ! ! I ~ 1_j ___ L.!.._J ' · ' · __ l_J ~ ·
o:fFH~t-:..i++l+ -j--1 ~+; 1 1 'FT,, f+~~-}1-+-fffJfi~ , 1 ,.,, , t, ng·· ·+ , . , -: · .\+ITITTTnTn71JJ ~-Fl-TH-t-·_ H-:+ ~+t1+>::-c : 1 m!'~,-m.J~ -~ ffi :i-1-·+++ Y-ffitt:t~Hf{,;-,:t➔_'. ~ ~:+I+ L-:-tj::-r+,l,ml-1-~W±_-l±!-l~f-· m1IJ41 · ~ri=-1 '-· I i :i-:;:-·~ 1 --l ~.; ,.t +++tt -+t I I ~Tl--"""f:1"1": _ !7 L. "',-+j-t, +I 1--'-t-~ 4 · TT +
I -I I : _r T-l-11-· 't. L. ' i-: I i I ' • .,. : n·n1 ..j I ! . .-ttt ' i ' ' I .w :, +-1-n-:t.;
_I ,;:, It . ' --~-~1--..... i.:,-1 . L I I I -I • • --'··-t-+-+-+-+-+-1-<--'-.' I-i-I ' • • l_.j._ ~ ·n •i -I I ,1 I i, i • i ! i ' t i ii t , , , ' J• ;-
-,.... : i ,, N 1 'H 1+1 ! I I I I Ht" I ' ' •3ir--I .. I I . II ;.' .:r-. II .-tpT I +-7-+-+-+-++-1 I ' I _I -ff1-~-.... mr/-..L . · .. ·. , .... · .. , .-, i __ J, tt·,-,,,,, ., Ll.· '-. _. . -H··•-~---~ . . 1 .,_ • f-1-H-h+ 7 ,:' )., • \, .. J ~.tt-. L .• • ~8777-ti_TM-....ff ,v~ i1~1. 1;;1t ttfl ·Y-+-t W--, 1 , 1 1 . • 1 _ ,__
: : ,' ,1 ,1 1 .•••• ·"it. .. , .. • ' .. ::rd ~-,--":"' ~~ , .. , dt-"-~---:-:: ... • • .. ".. ... ,I • t::.' . : .... -~--I ·-1, J~: f+ I l~ · n · · • -"• • ' I .. "~ .. ..._ "" • • ••..
I • "T , I . N:-+· IV.. • •• .• • ,,., ·-•• ,i> ", ' r'• I I ·1-:~-· ,,., ·. . I ! '
I . •: .:·i" ,~· '-i '!,. • •. ·,,' .'.::···,··:·:·~ ,.·r.a .,.. •_r\ ·, .... ··;,'. :: ··:i:<·::·· t ,: .,, ',--,
! . •Is I ,, ' • •• .,, -.,,' I~~ rj.-t-" !'lo· fl i •+.~~-.-. :tT-[~-. ••r•;' .
_l : • " • -., • r-1 •• . • • •• ,\ • :, : • rT! ... :-; ~ ...... r,;i .. .-I ~,' 1-~ : '~ •, • • \ •,· ': . d ·: I ' I !
County of San Diego
Hydrology Manual
• '
, I I I I ~ .. -•r-•• •·· -• , •. , J,:-• ~ • •• . · ..,_ ,, , .V • ' l 1•, ', ', l •, •• , • I • . I' , •
. ,.i , v •if , . , : ••• ... ,,: -•• ~ • _ -~-( •1 • • :,_, ~u;.,.Ll,.:: _, .• _; \ · _ · ..... : .. / , . . . .. . _ Rainfall Isopluvials
,::.. I •l• 1 . j!..!.'. •±~I .. , '.-,•.1, I Ir 1 ~ /1 1,a:i 'i • •.t"": .. ~ !"IJ. •••• l·,_i:, ~ ••••• • ••
./.• ,• :..:.,.µ • · :i:.'. r,.t,J•,.I Y,•:j\',[1 ', :t i li'•, I-~.' :\!.",•."'.•·'"'.1',-J_9_i-'-1_f=.:._f::_F_·_+-0+,,+_.'-'-+,+JI .... ---------------
!\."'-~ n_ ~I"='. J. 'ri 1 11 1 i-:1.<' ,~~-· 1 'f.r· · .• . LI hJ-J~~-'++_' t-H-~+l"t'"·'1 i I"
1L£~ 1 ,. 1 ,. ~ , 1 i ~ _' c1"'1]:>"f..~ 1 r· -.-n:::r .. u,_ •, \' ...... , .....
L>' • I ' fT 'fJ .. ~·t' I •., • , •:r,", '. • 100 Year Rainfall Event-24 Hours
I 'II.!! I. ·i , • · If-. •' f:;
'i,1 J •~ • -~ I !" 1 -I"~ )';. : / 1 ',I
1A · :; 1 ''•I .. , , :I•, -1--.:-.:1· : ,,. i ••• · • -• 1 I Ii 1 1 1111 ·1117711'n"I_J~y! ,. • , ill rn 'i. ,· -. ,I' •,j --·· I , _ '·••·~ ¢ •• rTT{ . . . ..;,..i.
I I I I I I I Ii I I I I !Cl I Ir-i:, ~ ;. ; • ~ I-, 1,,1,.f-•.•• ., .I l , 'I' , , , , ,._ '. I , , J I , ~ •. • •. I ~.
I I I I I I I
I
I I I I I I I I I I '· '_i •• 1· .-... • •• _., •_j,_J[ ,_'.:,', '· _-P: , •• -· · · .1:· ., .. J,, •' : • •••• • ·p . ,,+ ,_-+ !-4-!-+-H
1 1 1 1 11 1 : 1 1 I , 1 , 1 1 1..-!1 ": n 1 •• , •• 1 • .-,.1,1 1 T 1 f . · ·" · -::r r.t" • . -. :,,...• ➔·-,•1-t-+-+-< 1
'
11 1
T :HI ;, 11 :-•. :.-..J "· ,-..r ,1,. ,-.., ·n.: ,., 1 ;•t• .:1---1....b \ r,1.... •
~j'.J I··I-r i i d..Lk --~ . :·, ;··i •. '•L' • ·H.l. ! i J -~L i', 1 11 L
~j
.'\.!1 I i I i l Cl j IT ~~7![""""' "'I:! -,.., U" 1·· . 1/1' --; I TJii'1-· T' ' ! ,1•·1. •,\
; I I i I rrn· ..I. I , . ,, 1: ! v, ,r [,:. ,i :i-L: :. •--i\ · f ii ~ ... -· j:-' j I ~ T J I • •' .' _j,' i--i.l 3 ' ! , l.-1• , -, 1 ,:, I• tr ~-,,· ! , 71· •1/\1 ·•. :r ' I I . ··1 l•' .. ·,-~ l-t-+-fi-t-t-t-t-il
,T 'i"' I , t!1 ,., ii.A .' ,. •. ~ I --R~I!, truiJr.l """,11---i l• , ; 1u;u, l · ·.f,!i _ ,. 1 , ..
: : 't-' ,
1
P-IEP• =} ~--~• •J'... L~• IJ ";, ~) .. :~~ • \ :~•: ::,. J ~::;~ ~ ;: .. • -;/~: · .'i .. • .•. ,
11~+~. ' , ,;/', "'""" ·· · ·· \[ • I , , " ', "I. • • •• I :1 ' • f"-F · J_ .... ;-4-!..JI I t ,v •-, I-' • ~• •1'.',,i ,• , }, ·r ~• ', ,·J\' .. • :J•J :I .' . ,: •~__j ll"i 'I I l'i. 1 t--l-t-ttfN i / 'o.-.·~7e-_.;;·:·:.::t"'·-· ·.· ! I • I •,. • -'";',•.-::J"'_P·. 71-,1, .· ·,,-t-+++--j ,--,--±1-! .. I BTT · -· : ;+-'+-t•t-":: !l, : : "1 \' . '\, • . • l 'P ', ,1 I I I I.:
J' ++++-I I I 'j,,! , _.,. • lb .'r. :J_)_. •...L.tf'J.: .,_ •. f. l ', I', , I _ ~·
' ' : " I I I ! I I i.. ,,r .. ~ ", ' I ! I '• -'i', , .... ,... i\.! ' J
i I ' ; i ' ' ! I i ' ! • .L l/ I' ... l ~ I ' ! •, ' '•i I i .•, ., : I I . i ; t't ', '• ,·. ' I r,,. I,!(; : '
,'.1. I I f i 111 !, +-+ N_ ~ #-r-~--·i·, -.. -~--tf' i 'f""'I .11 -:-Hl~· .. £,!'H•·.·~-r,r.,.!_,...~~
i 11 -, 1 1 1 1 :, ,, , • ,.... y , ,,i,...-"'.1 ,,. •"'t-i!l 'r;.:' ; J ·i •;.1.,l J/i:7 ':,· 1'1;"", 1-.LL,.''1• 'ii 11--H++ · 1 :+ L! 1 +t+' +u.L...~ · ;--J ·· · .+· -1· •• , •• r N _, ;;; • ,., 1, , 1 ,• 1:,_+•: ·•J ' ·,1 t '+'l 1 1
TT:) Lt."(
lsopluvial (Inches}
= lf.o•J
1:-, .. I I I , , , :lr, I · 'I I ; ! ··• ·1 I ., J.,,-,, I •· 1 "1 1 ,..,. I•!•:• '1-:., I : 1 • I ,.I I
' • J-r n ++t-i I I I; , I ''.', '1)-><t ••• ,I ·: i I <!$! 1:1 I •··•·•···' ! i I TT ', .•II• I ~-++L ·4?rr 1~ I : I: '.-i--l-H-1..Ll_t,_w• .. : .. :: . i--r1 _' ... -~t""N.r,. ;,l!l r,r..' '\,,; ,r:mt--;;:-r-" .. ,JTT,jj__J_'.,\': ·.:r-1~.!•rrn···' I 1--H-+~+ffii' :Ifffi• ;-1 -L/--..,...W'.,. ! j: '_. / i .;..~?Y'n. . -~ ,, . ·H· .L . .J,r '-J-1 •-½• . r· •~-"tt-!\,, r,u,.ff':~~,J~c-l---i.177#•'_1 I,· •'JJ±·r-1",. 1· T.i ---1·-+-j-'-' . . ffif. l . ·oo· '-W...;. '<ef+. . .• . .•. ~-:i, .. t.J_ . i· .• ~ 1·-· -,-,-, 4t'' .,..___ ... ; ,. . , ~ . ! µ opw ~ mi-h-,M~ '~~L -:: ·, ! : 11 ~ J1'1I Y< ~_,.:. •• • •• , •• :;1,l;rr-;f-t--~·.,..tfc:.:.; e':/.'1, d:,t;Hi#' .. :' ';, 1 •• l,;--1 ·_··j1~.ei !o. • '-!·i",;. ·•,n:·--·~·-11:-:~.! ---GJS s~anGIS
i , ' ! 1
·, -~u-· ·t-'-H-+->-' •-~..LL Ll__! ! ae ~:J,>.~ · .. ·(•'.e 1--"'~' ,-i:...; . t' ,\ I .. JO,' ':J ) >~' I I I ; .>·' : _17 ~· , --i 'W-L ; ·,. 1 . J , \ --_.
I '-hl/ I I ~H--+ +++' ,' m+ '1tl.w 2.J:p... • . ·c,,,,,,r o,::,,rr .. '""""•'!.,Lt •:·t :ti' -..L !:i . I"-..,..I I,,· I, ·_ : -"' ,.,.., t-t:::t '.-.:1:~c=c -·-=-Wc Ha,dian D!cgoCmcrcd! rn-=', '-j...l-"-LL_f : I'' ' . : J..•' , I ~,., -~ ·..i,·f'"4;f ,··n _J,,._~,,,-, r:-·~· rT,: .-1_, • ··Lr. 'l•i:. J .·, l I' J. " -:.......-. : 1.1..1 --·-
1 / I j • -~-•
1
J • -;'} • 1
, I 1-I +-t-t"i; ~ '• -:,1 • -~1 • r-n ,' •' /: ""T::f-• • t-t-1-i··! ••~.~.rt.1 I.!" .. t 7 • ?r,..,r-~-. -~1 i•' -r r77-. j 8 [ ; i ·1-llilll,l,IIIBPAOW>m¥fflWOIJT'WNl!IW(NOFNNKNl,Ef'!IEREXPRESII .;..+mi. iii_ ,:!7,++j-+_. -,·r-t--t----r-;.•l,( _• lu~,f1:-:--_t;(: •lrt.i,,_t,_~l-.-,r-1·~-r-._-,TI ___ ·i:r':,"'l ... l .• ,,!' I 1J711+1,"tt-ri°", N :::.,~: ... ~'~=-'" UJ 7=t -+-'mf+++ r'-+-U.: ......... u.+~ . i · . -,-t.R,,.~--+-'-1,..,.."·· ~r +H-++-., f tT'-t:tw.1" • +--M--B1·:+h~ ; ~itffi;_ L ~j:--m-i.~;.U..:C :1-r.1=+_
1 ·± ~~ .. ; I ,'·r~.':: ~,,+~ H~+,~· '_•-.::~-+i ~¾rb. '1-1 ·~-i~-+-h+if~++ :.:.i.~_ L~~u ~1.1± :::=-..::.-::=-::-.=~:=.:--t7--', rl·+' ' , 1 I 1 l, , : ' , · , 1 , , , , •1r!, · • ! 1 , -, ·: , , . .'v , : ~n ..,,,,., . , , LL · · , , , , T i--i-·: 1 , , • ~-: 1 ....,~,tL\llill4G,. -p +-:..f-m rt I :-r ti-+-r r-:~ _"_-~, --i-H-·-::•l-n+.r~: l-i++-+-fT~.y+ ... 4tttL l : . -r-:r--,·-n .=r.q q ftl .1 --H /TT:t=tl1+}t--4++ll1. I r . ; ~ :::=,-'~.;"',,=-.~--..,
T-t~io~ --I L..i.t : f-t ' : --'--'-I ti' ' ; : ; . i l : ' : . ' I ! ; ! I ; ; ' ' ; ! : : i : I : ' i ; . ' : : ' i . . i : ; ! : I : : ' ' ; : I ' : : : I ; ' I I ! i I : : ,i2,3-bffi s r q:r.r -' I L'J I;, -t-1 I f-r j_ ___ :"'-.,-~ ''-++-'-+'±q(·,n,·-.c.:..4·--;-u "'I-,~-.•··-•-; ··--rm~·r,J. ,-,-1-· . +d.l h -'-+-t-•-~~-i--f-.-3 0 3 Miles l:-~-t..1=aJilfJ:_ FJ-~a: ~t 2 ~ ~~JL~+2t!-rtt~1 J ilr~t_1 ~1IHTHH~lH-Hm+i-t-rLt=R-~~l-4?+ll-i !-'. t+ ~~:~~rrnt-F ~-,
---...
---...
-,.
-
• -..
-..
---...
-
•
•
•
•
• -,.
--
•
• ..
• -
4
•
◄
CJE
APPENDIX D
HYDRAULIC CALCULATIONS,
EXISTING CONDITIONS
& PROPOSED CONDITIONS
• I a I • • • I * I • • • • 1 I i I l t I I i I i I ' .
Pipe Capacity Check
Manning's Flow Evaluation of Pipe Capacities
Max mannmg·s nowrate 1n eacn p1pe w1m a1pna = :>.Lo raa1ans
cfs in
US EL DS EL L So n D alpha area perimeter Q V h T F
P1 50.08 49.65 25 0.0172 0.013 0.333333 5.28 0.085 0.88 0.27 3.2 3.8 0.16 0.06
P2 49.65 48.6 75.5 0.013907 0.013 0.333333 5.28 0.085 0.88 0.24 2.8 3.8 0.16 0.06
P3 48.6 47.66 33.84 0.027778 0.013 0.5 5.28 0.191 1.32 1.01 5.3 5.6 0.24 0.20
P4 47.66 47.54 45.94 0.002612 0.013 0.5 5.28 0.191 1.32 0.31 1.6 5.6 0.24 0.06
P5 47.47 47.42 45.14 0.001108 0.013 0.5 5.28 0.191 1.32 0.20 1.0 5.6 0.24 0.04
P6 47.42 47.31 43.38 0.002536 0.013 0.666667 5.28 0.340 1.76 0.65 1.9 7.5 0.32 0.11
P7 47.31 47.2 47.05 0.002338 0.013 0.666667 5.28 0.340 1.76 0.63 1.8 7.5 0.32 0.11
PS 47.2 47 15.74 0.012706 0.013 0.666667 5.28 0.340 1.76 1.47 4.3 7.5 0.32 0.25
pg 50.08 49.65 25 0.0172 0.013 0.333333 5.28 0.085 0.88 0.27 3.2 3.8 0.16 0.06
P10 49.65 48.9 60.3 0.012438 0.013 0.333333 5.28 0.085 0.88 0.23 2.7 3.8 0.16 0.06
P11 48.9 48.5 26.34 0.015186 0.013 0.333333 5.28 0.085 0.88 0.25 3.0 3.8 0.16 0.06
P12 48.5 47.71 48.18 0.016397 0.013 0.5 5.28 0.191 1.32 0.77 4.0 5.6 0.24 0.15
P13 49.6 48.3 15 0.086667 0.013 0.333333 5.28 0.085 0.88 0.60 7.1 3.8 0.16 0.15
P14 48.3 47.89 45.26 0.009059 0.013 0.5 5.28 0.191 1.32 0.57 3.0 5.6 0.24 0.11
P15 47.89 47.7 29.18 0.006511 0.013 0.5 5.28 0.191 1.32 0.49 2.5 5.6 0.24 0.10
P16 47.7 47.47 60.92 0.003775 0.013 0.5 5.28 0.191 1.32 0.37 1.9 5.6 0.24 0.07
P17 48.7 48.4 32.69 0.009177 0.013 0.5 5.28 0.191 1.32 0.58 3.0 5.6 0.24 0.11
P18 48.4 47.2 30.98 0.038735 0.013 0.666667 5.28 0.340 1.76 2.56 7.5 7.5 0.32 0.44
-...
..
...
--..
-
--...
----
-
•
-..
Design Capture of On-site Inlets
1-ft x 1-ft Brooks Box
weir equation
clogging 25%
C-coefficient
L
L effective
approach head
Qcapture
9" x 9" Atrium Grate
clogging 25%
C-coefficient
L
L effective
approach head
Qcapture
Q = CLH11{3/2)
0.25
0.3
4
3
0.5 feet
0.32 cfs
Q = CLH11{3/2)
0.25
0.3
3
2.25
0.5 feet
0.24 cfs
.. ..
-
• -,. .. ..
-.. ..
•
•
"'
• ..
-.. .. ..
•
• .. -.. ..
-..
-
•
•
•
...
• -..
...
,.
CJE
APPENDIX E
FEMA FIRM PANEL
SEQUOIA AVE
ZONEAE
(EL 11)
~
MAP SCALE 1" = 500'
0 250 500 750 -----·--1,000 ~3:::=E::=:=:3:::=:=:::::E=:=:==3C::::=:::=:J FEET
'(!)
Ill
111 ,,
I ~
0
PANEL 0764G
FIRM
FLOOD INSURANCE RATE MAP
SAN DIEGO COUNTY,
CALIFORNIA
AND I NCORPORATED AREAS
PANEL 764 OF 2375
(SEE MAP INDEX FOR FIRM PANEL LAYOUT)
~
COMMUNITY
CARLS8AO, CITY Of
!!l!!!W ~ ~
06Cr.285 0764 G
NotatoU..-TMMapNUffib9rlho'M"lbek'Jllltlahould be....ct
'ollflen pl~ map Ofdel$. ltle ~ Nvfflber lhown fflWe
ahauld be UHd on NUfanc.-~ 1ot 11'11: w:,jeet -MAP NUMBER
06073C0764G
MAP REVISED
MAY 16, 2012
ftderal Emtrgcncy Management Agtncy
Thia I• an offlcl■ copy of a portion of the abol,,e referenced flood map. It
waa extracted using F-MIT On-Une. Toi• map does not reflect changeo
or amendments which may h...., been made aubeequent to the date on the
title block. For the llllnt product Information about Nation■ Flood Insurance