Loading...
HomeMy WebLinkAbout1728 CEREUS CT; ; CBR2021-1464; PermitPERMIT REPORT Residential Permit Print Date: 05/24/2022 Job Address: 1728 CEREUS CT, CARLSBAD, CA 92011-5119 Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: BLDG-Residential 2155021900 $3,624.01 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Alteration Description: MAHER: 65 SF REMODEL BATHROOM/WINDOW-DOORS REPLACEMENT/ELECTRICAL Applicant: PERMITS IN MOTION 4715 60TH ST SAN DIEGO, CA 92115-3802 (619) 994-5557 FEE BUILDING PLAN CHECK FEE (BLDG) BUILDING PERMIT FEE ($2000+) STRONG MOTION -RESIDENTIAL (SMIP) SB1473 GREEN BUILDING STATE STANDARDS FEE PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL Total Fees: $196.46 Total Payments To Date: $196.46 {city of Carlsbad Permit No: CBR2021-1464 Status: Closed -Finaled Applied: 05/21/2021 Issued: 07/29/2021 Fina led Close Out: 05/18/2022 Inspector: Final Inspection: Balance Due: TKers 05/18/2022 AMOUNT $43.22 $61.74 $0.50 $1.00 $49.00 $41.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check era (,2C2( "l"'iu 1 ~21 -(j .-Est. Value :::i u:)' .,.) I. · PC Deposit ----1·'----f-1 ___ _ Date _S_,,____/:J_,__/ -f----"(;__..J. /_ Job Address _ __.t~-_.}_2""'"'9~=--' ... f;....._e_if:..._.._e...,1.,,.. __ .,_lc"":;,1-, _,.(-"'0""'('""',.;;i:<:.__a{-__ .Suite: _____ APN: __________ _ CT/Project#: _________________ lot#; ___ _ Fire Sprinklers; 0 YES O NO Air Conditioning: 0 YES O NO Electrical Panel Upgrade: 0 YES O NO BRIEF DESCRIPTION OF WOFtK: 0 Addition/New: _____ living SF, ___ Deck SF, ___ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? 0 YON New Fireplace? 0 YON, if yes how many? __ . ,..,.--/ ~model! l .1 "'::) SF of affected area \.>1 Is the area a conversion or change of use ? 0 Y ON 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ osolar: ___ KW, __ Modules,Mounted:0Roof0Ground, Tilt:OYON, RMA:OYON, Battery:OY ON, Panel Upgrade: OY ON D Reroof: ________________________________ _ 0 Plumbing/Mechanic~ __ t,_~1-=--; x.;:._;,:·_...,F__,.lt::"'-:,-'(..;;..\-_lf_,_· .a.,C_(..-"\..;;.\ ____________ _ □ Other: Los ¢ bC..-=-:>,l0J.I' \)C¼lo L,) I 'rldl,)L.0 2 e ?l~C~L APPLICANT (PRIMARY CONTACT) Name: V2N':M;:\::::, . \Y) mo-HoD I PROPERTY OWNER Name: C'}aCYD ,\.s; I Address: _________________ Address: rnx?,, Ce.y c'.. \, ,~;, <'....01.,.rx: \- City: _______ State: ___ .Zip: ____ City: Cc.,,l(\::,k·)",o\ State:Lia:_Zip: Ci2o I 1 Phone: C Q \ 9\ cv.\t.t · "S 5 5 "J Phone:------------------- Email: '.f ?ti 00 ·, ;t') @?,;,-:'YOO: t: ') .. A \'YJ 01 \/llJ <. ~-~v1Email: ___________________ _ DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: C Name: \ )D1? C k}oyyµ,, Ex?'(('. '::6; Q n .,.,) ) Address: Address: A\ 3 ~ l:·::h:i&(,u~Y 9r;, City: _______ State: __ Zip: City:'5:1 T}~ State:~Zip: "h.-1\\ Phone: (;hone:{§~! -(p&4o Email: -----------------1 Email: c~u;J0,.j0Q;.SO!'wk,:,Tru-JCf.M,\c&\ j~.c~ Architect State License: Sta_te license: ______ Bus. License: /t>o 8 c, 2, :> (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to constru,;t, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the contractor's Llc>!nse Law {Chapter 9, commending with Section 7000 of Division 3 or the Business and Professions Code] or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation or Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than nve hundred dollars ($500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 8-1 Page 1 of 2 Rev. 06/18 /"{~PTION A): W0RKERS'C0MPENSATION DECLARATION: / I hearby affirm under penalty of perjury one of the following dee/orations: Qi have and wlU maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. ~ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit ls Issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: (!., tA,i?; \TO L. PolicyNo.".lO:Z:Z"\1."'.\ --:LO Expiration Date: \o-0\ -1,.0'2..\ \ •' D Certificate of Exemption: I certify that in the performance of the work for which !his permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employe, to criminal penalties and dvil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in SC!ction 3706 of the Labor Code, interest and attorney's fees, CONTRACTOR SIGNATURE: _ _;:-_·~-=,.(=--',1'-'-~~"-----· _______ lJAGENT DATE: S /I tl/F:oc/ = I I ( OPTION B ): OWNER-BUILDER DECLARATIQ~ I hereby affirm that I am exempt from Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensatlon, will do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Profei;slons Code; The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such wori: himself or through his own employees, provided 1hat such improvements are not intended or offered for sale. If, however, the building or Improvement ls soltl wlth!n one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Or, as owner of the property, am eKcluslvely contracting with ltcensed contractors to construct the project (Sec. 7044, 0uslness and Professions Code: The Contractor's License Law does not apply to an owner of property who buUds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). DI am exempt under Section _______ ,Business and Professions Code for this reason; L I personally plan to provide the major labor and materials for construction of the proposed property improvement. QYES 0No 2. l {have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person {firm) to provide the proposed construction (Include name address/ phone/ contractors' llcense number}: 4, I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number): S. I will provide some of the work, but J have contracted (hired) the followlns persons to provide the work Indicated {include name/ address/ phone / type of work): OWNER SIGNATURE: _________________ .□ AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction I ending agency for the performance of the work this permit is issued {Sec. 3097 (l) Ci\/11 Code). Lender's Name: ____________________ Lender's Address: ___________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: ls the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? ! Yes I No Is the applicant or future bulldlng occupant required to obtain a permit from the air pollution control district or airquallty management district? Yes/ No Is the faclllty to be constructed within 1,000 feet of the outer boundary of a school site? Yes/ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application :and state that the above information Is correct and that the Information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the Oty of Carlsbad to enter upon the above mentioned property for Inspection purposes. I AlSO AGREE TO SP.VE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit Is required for excavations over S'IY deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void If the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the bull ding or work authorized by such permit Is suspended or abandoned at any time alter the work is commenced for a period of 180 days. CBC section 105.S. APPLICANT SIGNATURE: _ ..... /4"-"'-'""M.::..,..."".c::::>,_.,. _________ DATE, ~"5-/ _,_I -'-"B+-L-... zo""-"'-2 ..._1 I I 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 , '" is"' PERMIT INSPl;CTION HISTORY for (CBR2021-1464) Application Date: 05/21/2021 Owner: TERRENCE MAHER Permit Type: BLDG-Residential Work Class: Alteration Issue Date: 07/29/2021 Subdivision: CARLSBAD TCT#72-34 UNIT#03 Status: Closed -Finaled Expiration Date: 08/15/2022 IVR Number: 33495 Address: 1728 CEREUS CT CARLSBAD, CA 92011-5119 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Status Checklist Item COMMENTS BLDG-Building Deficiency 02/14/2022 02/1412022 BLDG-17 Interior 176663-2022 Passed Tony Alvarado lath/Drywall Checklist Item BLDG-Building Deficiency COMMENTS Interior drywall patching at two locations in ceiling and wall-approved. BLDG-18 Exterior Lath/Drywall 176662-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS Exterior stucco wire lath. method of attachment-approved. 05/18/2022 05/1812022 BLDG-Final Inspection 182973-2022 Passed Tim Kersch Tuesday, May 24, 2022 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Passed Yes Complete Passed Yes Complete Passed No Complete Passed Yes Yes Yes Yes Yes Page 2 of 2 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBR2021-1464) Permit Type: BLDG-Residential Application Date: 05/21/2021 Owner: TERRENCE MAHER Work Class: Alteration Issue Date: 07/29/2021 Subdivision: CARLSBAD TCT#72-34 UNIT#03 Status: Closed -Finaled Expiration Date: 08/15/2022 Address: 1728 CEREUS CT IVR Number: 33495 CARLSBAD, CA 92011-5119 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 09/28/2021 09/28/2021 BLOG-21 167420-2021 Passed Tim Kersch Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/30/2021 BLDG-11 167581-2021 Passed Tim Kersch Complete Foundation/Ftg/Piers (Rebar} Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/14/2021 10/14/2021 BLDG-84 Rough 168563-2021 Passed Tim Kersch Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes 10/27/2021 10/27/2021 BLDG-17 Interior 169521-2021 Partial Pass Chris Renfro Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 11/23/2021 11/23/2021 BLDG-17 Interior 171275-2021 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-27 Shower 171276-2021 Passed Tony Alvarado Complete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency November 22, 2021: Yes 1. Hot mop/shower pans inspected and approved per Tim Kersch. Per contractor representative-Spencer. 02/08/2022 02/08/2022 BLDG-34 Rough 176231-2022 Partial Pass Tim Kersch Reinspection Incomplete Electrical Tuesday, May 24, 2022 Page 1 of 2 INTERWESl DATE: 07/16/2021 JURISDICTION: City of Carlsbad PLAN CHECK#.: CBR2021-1464 PROJECT ADDRESS: 1728 Cereus Court SET II PROJECT NAME: SFD Master Bathroom Remodel □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. ~ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Permits in Motion ~ lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: PiM ~ Telephone#: 619-994-5557 Date contacted: (by~ Email: permits@permitsinmotion.com Mail Telephone Fax In Person ~ REMARKS: At proposed new doors, please show how compliance with section AV100.2 for pool safety will be achieved. (i.e. exit alarm; self-closing, self-latching device with release at least 54" from the floor, etc.) By: Ali Doudar lnterwest 07/09/2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 • DV INTERWEST DATE: 06/11/2021 JURISDICTION: City of Carlsbad PLAN CHECK#.: CBR2021-1464 PROJECT ADDRESS: 1728 Cereus Court SET: I PROJECT NAME: SFD Master Bathroom Remodel □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8] The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8] The applicant's copy of the check list has been sent to: Permits in Motion D lnterwest staff did not advise the applicant that the plan check has been completed. J::,<'.J lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: PiM Telephone#: 619-994-5557 Date contacted: (by: ) Email: permits@permitsinmotion.com Mail Telephone 0 REMARKS: By: Ali Doudar lnterwest Fax In Person Enclosures: 05/24/2021 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 City of Carlsbad CBR2021-1464 06/11/2021 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2021-1464 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 1728 Cereus Court FLOOR AREA: 65 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 06/11/2021 FOREWORD (PLEASE READ): STORIES: 2 HEIGHT: 8'-1" T.O.P DATE PLANS RECEIVED BY ESGIL CORPORATION: 05/24/2021 PLAN REVIEWER: Ali Doudar This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California I Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC, 2019 CPC, 2019 CMC and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.1 plan sheet number1 specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad CBR2021-1464 06/11/2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Ali Doudar BUILDING ADDRESS: 1728 Cereus Court BUILDING OCCUPANCY: R-3 BUILDING AREA Valuation PORTION (Sq.Fl) Multiplier Remodel 65 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Building Permit Fee • l lU t~I :. 1997 UBC Plan Check Fee • I ·,\I Fl. Type of Review: Q Complete Review D Repetitive Fi!e • i Repeats 0 Other □ Homy &Gil Fee PLAN CHECK#.: CBR2021-1464 DATE: 06/11/2021 Reg. VALUE ($) Mod. 3,624 3,624 D Structural Only $39.891 Comments: In addition to the above fee, an additional fee of$ is due ( hour@ $ /hr.) for the CalGreen review. Sheet of City of Carlsbad CBR2021-1464 06/11/2021 PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 1. City of Carlsbad requires that all plans provide completed Climate Action Plan (CAP) Consistency Checklist, city form B-50. 2. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. 3. As a reminder, All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). GENERAL RESIDENTIAL REQUIREMENTS 4. Sheets A2.2 and A3.1 are missing from this package. Until complete scope of work can be realized and proposed plans can be seen can the project be completely reviewed. More comments may apply. 5. Please dimension a landing at the exterior of all doors. Width of the landing shall be not less than the door served and shall have a dimension of not less than 36" in the direction of travel. CRC R311.3 6. Please coordinate Energy ratings of all proposed fenestration with the Energy documentation. CF1 R shows a U-factor of 0.30 and SHGC of 0.23. 7. Please identify which windows and doors are to be tempered I safety glazed. As a reminder all fenestration in doors is required to be tempered. City of Carlsbad CBR2021-1464 06/11/2021 ENERGY CONSERVATION 1. Include on the Title Sheet of the plans the following statement: "Compliance with the documentation requirements of the 2019 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CF1 R shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." 2. Please ensure at least one wall switch-controlled lighting outlet is to be installed at the exterior side of outdoor entrances or exits. CEC Article 210.70. 3. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom. CEC 210.52(0). MISCELLANEOUS 4. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 5. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 6. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ali Doudar at lnterwest. Thank you.