Loading...
HomeMy WebLinkAbout2210 FARADAY AVE; ; FA050086; Permit6/16/22, 3:49 PM FA050086 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2210 FARADAY AV Permit Type: FALARM Parcel No: 2121205500 Lot#: 0 Reference No.: Permit No: FA050086 Status: APPROVED Applied 9/19/2005 Approved: 9/19/2005 Issued: 9/19/2005 PC #: Inspector: Project Title: RESEARCH CENTER POINTE 2 FIRE ALARM INSPECTIONS @ $60 EA Applicant: Owner: CITADEL SYSTEMS PO BOX 231871 760 497-2308 - Fees($) -- 120 Add'I Fees ($) Total($) Balance($) 0 120 0 1 /1 RESEARCH CENTER POINT 2210 FARADAY A VE, CARLSBAD CA Fire Alarm Submittal Submitted By; SYSCOR ALARM, Inc. P.O. Box338 Cardiff; CA 92007 Lie. C-10 # 773773 fAosoo91o FJ ~ I I 5 2 4 3 I 1 3 I RESEARCH CENTER POINT Equipment List Description Model Fire Alarm Panel 5700 Fire Alarm Annunciator 5860 Smoke Detector SDS0S-APS Heat Detector SDSOO-AHS Addressable Input Module SO500-AIM Addressable Relay Module SD500-ARM Manual Pull Station SDS00-PS Hom/Strobe l 5cd P1224MCW Connection to existing Waterflow Switch Connecetion to existing BACKFLOW Switch Wire l 8/2Cond. (Initiation) Wtre l 4/2Cond. {Indicating) Manufacture Silent Knight Silent Knight Silent Knight Silent Knight Silent Knight Silent Knight Silent Knight System Sensor Atlas Cable Atlas Cable CSFM · 7170-0559:144 7170-0559: 144 7272-05S9:129 7270-00S9: 127 7300-0559: 132 7300-0559: 132 7150-0559: 136 7135-1653:163 7161-0972: 100 7161-0972: 100 --- INTELLIKNIGHT MODEL 5700 FIRE ALARM CONTROL PANEL lntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable solution. lntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The lntelliKnight 5700 performs drift compensation and calibration checks on each of the sensors in the system. The basic lntelliKnight 5700 system can be enhanced by adding modules such as the Remote Annunciator, the Serial/Parallel Interface (for printing system reports), and an Intelligent Power Module. The Model 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Up to 50 addressable points. • Up to 125 zones and 125 output groups. • Uses standard wire-no shielded or twisted pair required. • Built-in digital communicator. • Central station reporting by Point or by Zone. • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC. • Distributed, intelligent power. • Drift compensation. • 13 pre-programmed output cadences, (including ANSl-3.41 ), and 4 programmable outputs. • Notification circuits can be configured as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power. • Built-in synchronization for appliances from Gentex®, Faraday, System Sensor® and Wheelock®. • Built-in annunciator with BO-character LCD display. • RS-485 bus provides communication to system accessories. • Up or Download programming, event history, or detector status via remote or direct connection. • Built-in RS-232 interface for programming via PC. • Built-in Form C trouble relay rated at 2.5 amps at 24 voe. • Two built-in Form C programmable relays rated at 2.5 amps at 24 voe. Approvals: UL Listed / NFPA 72 (File No. S2766) -Central Station CSFM Listed -DACT -Local Protective Signalling System -Water Deluge Releasing Service MEA Approved 429-92-X Vol. XVI Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A at 24 voe 2.5 amps at 24 voe of power-limited notification power Standby Current: 160 mA Alarm Current: 330 mA Notification/Aux power circuits: 2.5 amps of power-limited power per circuit at 24 voe. Model 5700 Mechanical Specifications: Dimensions: 12-3/4"W x 15-1/B"H x 3-3/8"0 (32.39 x 38.42 x 8.57 cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31 X (two required) ® SILENT KNIGHT by Honeywell INTELLIKNIGHT FIRE ALARM CONTROL PANEL SLC Sensor Devices SD505-APS Addressable photoelectric smoke detector. SD505-AHS Addressable heat sensor. SD505-6AB Six inch base designed for use with detector head models SD505-APS,and SD505-AHS. SD505-61B Short circuit isolator base for SD505-AHS, and SD505-APS detectors. SD505-ADH Duct Housing. Detects smoke in HVAC ducts. Use with SD505-APS. SD505-ADHR/DTS Addressable Duct smoke detector with built- in relay module detects products of combustion present in air moving through an HVAC system. Provides form C alarm contact. The SD505-ADHR is compatible with the SD505-DTS, which provides remote annunciation and testing capabilities for the SD505-ADHR. Use with SD505-APS. SD500-PS/PSDA Addressable Pull Station with visible LED. Intelligent SLC Modules SD500-AIM Dry Contact Input Module. Designed to used with normally open dry contacts. Mounts in a 4 inch square electrical box. It features an indicator LED to show alarm status and a coverplate. 5D500-AIM -- ® SILENT KNIGHT by Honeywell SD500-MIM Mini Dry Contact Input Module. A miniature version of the addressable input module which is designed to be used with pull stations and other normally open dry contact inputs where a smaller size is desired. SD500-ARM Addressable Relay Module. Features 2 Form C output relays, designed to mount on a 4 inch square electrical box. Provides indicator LED to show output status and comes with a coverplate. SD500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500- LEDs can be used per system. SD500-LIM Addressable short circuit isolator module for SLC devices S-BUS Accessories The following items listed are devices that connected to the lntelliKnight's RS-485 Bus 5860 Remote Fire Annunciator The 5860 features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820. The system can be fully programmed and operated from any remote annunciator. 5880 LED/1O Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5496 Intelligent Power Module The 5496 is a 6 amp.notification power expander that provides four additional power-limited notification appliance circuit. 5 {~~· 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LEDs (15 red and 15 yellow) outputs and piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 1 O General purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Gateway Module Has one parallel and one RS-232 serial port for connecting any standard IBM-compatible printer to the lntelliKnight system. Interfaces with building control system. SKSS Silent Knight Software Suite 5660 Up Download Software User-friendly, Windows TM software for remote programming of the lntelliKnight panel using a PC. 5670 Facility Management Software Powerful end-user software allows viewing of detector status and event history via modem or direct connection. I • • I ,_, I • I $8:8~:iQ~::,: 1 _ _! R-.yk~~ a 883 Relay Interface Modules I . -------- 5700 5496 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 MADE IN AMERICA FORM# 350392 Rev. B, 10/04 World Wide Web: http://www.silentknight.com Copyright © 2004 Silent Knight LISTING No. CATEGORY: USTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7170-0559: 144 Page 1 of 1 Control Unit (High-Rise) Silent Knight Security, 7550 Meridian Circle #100, Maple Grove, MN 55369 Contad: Brian Foltz (763) 493-6400 *FAX (763) 391-5464 Models IFP-50 and 5700 Fire Alann Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to nstee's data sheet for addltional detalled product descrtptlon and operatlonal considerations. System components: IFP-50, 5700 7628 5860/5860R/RA-1000 5897 5496 5824 5865-3/5965-4 5880 5883 SDSOO-UM SD505-61B RA-100 3158 5220 120 VAC Prtmary, 24 voe secondary Control Units EOL Resistor Annunciator Power Supply Power Module Serial/Parallel Interface LED Annunciator LED 10 Module Relay Interface Board Line Isolation Module Isolation Base Remote Annunciator Reverse Polarity Module Direct Connect Module In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having Jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control units for use fn hfgh-rtse structures when used fn conjunction Wfth Model SKE- 360 Voice-Tone Evacuatio·n Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446: 100), EV AX-50 or EV AX-SOE (CSFM Listing No. 06911-1446:102): EVX-2ZA or EVX-42 Zone Splitters (CSFM Listing No. 06912- 1446:101); HMX-MP or HMX-OP Voice Evacuation System (CSFM Listing No. 06911- 1446:103), ~y firefighter telephone and separately listed electrically and functionally compatible initiating and Indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire _Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. For Rre Alarm Verification Feature (delay of fire alarm signal}. the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev. 05-28-20().4 I This listing i• based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test r""1s and/or other data but does not make an independent verification of any claims. Thia listing is not an endorsement or recommendation of the item listed. Thia listing ahouJd not be used to verify correct operational requirements or installation criteria. Refer to lia11te's data sheet. Installation Instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 9,2005 DIANE K. AREND, Senior Deputy Program Manager Usting Expires June 30, 2006 INTELLIKNIGHT ACCESSORY Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple-even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors-easy installation, stable operation, RF/transient protection, and vandal-resistant locking-and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the Windows™ based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built-in fire test feature • Simple detector calibration testing through the control panel or remotely through a Windows™ based computer software. • Vandal-resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved 5D505-APS Smoke Detector Specifications Operating Voltage: 17-41 voe Current Consumption: Standby: Alarm: .55 mA .55 mA Ambient Temperature: 32°F to 100°F (0°C to 50°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% Air Velocity: Compatible Bases: (Sold Separately) noncondensing 0 -300 FPM SD505-6AB (6" Base) SD505-4AB (4" Base) SILENT KNIGHT ® A Honeywell Company INTELLIKNIGHT ACCESSORY Model S0505-APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter= 5-15/16" 0 0 Model SD505-6AB Detector Base (front view) SILENT KNIGHT ® A Honeywell Company 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Diameter= 3-15/16" Height = 2 inches, including base Model SD505-APS Detector Head (front view) MADE IN AMERICA FORM# 350225, Rev. 02/004 Copyright © 2004 Silent Knight LISTING No. CATEGORY: USTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-0559: 129 Page 1 of 1 Photoelectric Smoke Detector Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Foltz (763) 493-6400 *FAX (763) 391-5464 Model SD505-APS analog addressable photoelectric type smoke detector with model SD505- 4AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed produd description and operational considerations. 39.S VDC In accordance with listee's printed Installation Instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7272-041 o: 149 •Rev. 05-27-2004 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test resutts and/or other data but doee not maklt an independent verifioation of any claim•. Thie lieting ie not an endoreement or recommendation of the item listed. This listing should not be used 1D verify correct operational requirements or installation criteria. Refer to lia19e'a data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 9, 2005 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2006 ~ --~ INTELLIKNIGHT ACCESSORY Addressable Heat Detector lntelliKnight® addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. lntelliKnight heat detectors are an essential component in virtually any lntelliKnight installation. The lntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other lntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors-easy installation, stable operation, RF/transient protection, and vandal-resistant locking-and it adds up to a flexible solution for all your fire protection needs. Model SD505-AHS Addressable Heat Detector The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. This means that it responds in alarm if the temperature goes above the trip point (programmed at the panel). The SD505-AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the lntelliKnight panel. If the temperature exceeds the trip point (programmed at the panel), an alarm occurs. The status LED lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. Features • Low profile, 2 inches, including base • Absolute temperature device • Simple and reliable addressing • Uses digital communication protocol • The SD505-AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. • CFSM listed • MEA listed • FM approved SILENT KNIGHT ® A Honeywell Company SD505-AHS Heat Detector Specifications Operating Voltage: 17 to 41 voe Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 32°F to 100°F (0°C to 37°C) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70' between sensors on smooth ceilings. Compatible Bases: SD505-6AB (Sold Separately) (6" Base) SD505-4AB (4" Base) INTELLIKNIGHT ACCESSORY Model SO505-AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Diameter = 5-15/1 6" 0 0 Model SD505-6AB Detector Base (Front View) SILENT KNIGHT @ A Honeywell Company 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Diameter= 3-15/16" Height = 2 inches, including base Model SD505-AHS Detector Head (Front View) MADE IN AMERICA FORM# 350229, Rev. 09/03 Copyright © 2003 Silent Knight LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7270-0559: 127 Page 1 of 1 Heat Detector Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Foltz (763) 493-6400 *FAA (763) 391-5464 Model 5D505-AHS electronic fixed temperature heat detector (analog) with Models 5D505- 4AB and SD~AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed produd description and operational considerations. Electrical: 39.5 VDC Temperature Range: 134°F -149°F In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Ustee's name, model designation, electrical/temperature rating and UL label. Listed as heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7270-0410·.147 •Rev. 05-27-2004 This listing is based upon technical data aubmitbtd by the applicant CSFM Fire Engineering staff has reviewed the test resul1s and/or ohr data but~• not mag an ind•~dent verification of any daim•. Th--\•ting~ not an endoreement or recommendation of the item listed. This listing should not be used 1D verify correct operational requirements or installation criteria. Refer to lis1Be's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 9, 2005 DIANE K. AREND, Senior Deputy Program Manager Usting Expires June 30, 2006 INTELLIKNIGHT ACCESSORY Model 5D500-AIM Addressable Input Module And Model 5D500-MIM Miniature Input Module lntelliKnight's addressable contact monitor modules combine fast response with pin-point location ID. A combination that saves lives and property. The S0500-AIM and S0500-MIM are addressable input modules for use with Silent Knight's lntelliKnight fire control pane,ls. The S0500-AIM and S0500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The S0500-AIM addressable input module mounts to a 4"-square box. The S0500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The S0500-AIM and S0500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation-a flexible solution for all your fire protection needs. Model SDS00-AIM and SDS00-MIM Input Modules The addressable input modules expand the flexibility of the lntelliKnight system by allowing the use of contact type inputs. Typical applications include manual pull stations and water flow switches. Features • Operates on Class A (Style 6 & Style 7) or B (Style 4 )SLC Loop. • Single contact monitor. • Up to 127 modules per SLC loop. • SD500-MIM mounts in a single gang box. • SD500-AIM mounts in a 4"-square or double gang electrical box, and has an attractive ivory cover plate. • SD500-AIM/MIM are DIP switch programmable. • Accepts up to 14 gauge wire. • Both modules UL 864 listed; comply with NFPA 72 • 2500 ft max. wiring distance from input module to contact. • CSFM listed. • MEA 429-92-E, Vol. 9 • FM approved CAUTION R f1<.,VE P \/lR PR! W ( il WJCIN< 0 SO500-AIM Operation Each addressable input module is programmed with a unique SLC loop address. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. If a fault occurs in the wiring, the module alerts the FACP. SILENT KNIGHT ® A Honeywell Company SO500-MIM Specifications Operating Voltage: 24 voe Standby Current: 0.55 mA Alarm Current: 0.55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: SO500-AIM double gang box or 4"-square electrical box SO500-MIM single gang box INTELLIKNIGHT ACCESSORY Model SD500-AIM and SD5.00-MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate. Model 5D500-AIM FRONT VIEW 0 CAUTION RrMOVE POWER PRIOR TO SERVICING 4-7/8" 2-1/2" SILENT KNIGHT ® A Honeywell Company 1 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com BACK VIEW 0 0 0-0 Model 5D500-MIM SIDE VIEW ~ 1/4" 1" MADE IN AMERICA FORM# 350231 Rev. B, 02/04 Copyright © 2004 Silent Knight INTELLIKNIGHT ACCESSORY Model SDSOO-ARM Addressable Relay Module Place relay applications anywhere on the lntelliKnight loop with the SDSOO-ARM Addressable Relay Module. The SO500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC. The SO500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SO500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices-easy installation and stable operation-and it adds up to a flexible solution for all your fire protection needs. Model SDS00-ARM Addressable Relay Module The SO500-ARM provides two Form C contacts rated at 2A @ 30 VDC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Features • Two sets of Form C contacts. • Contacts are rated at 2A @ 30 voe. • Up to 127 relays can be used on each SLC loop. • Relay programming is completely flexible-can be mapped to zone conditions. • Polling LED visible through cover plate. • UL listed, complies with NFPA 72. ~SILENT KNIGHT ® C.,'\lfTJON l\)V,'U< f\l<.I.::. tK "I 17!'!1"""' u_KMGHT 0 0 Model 5D500-ARM Specifications Contact Rating: Form C 2A@ 30 voe Standby Current: .55 mA Alarm Current: .55 mA Ambient 32°F to 120°F Temperature (0°C to 49°C) Mounting 4-square I I INTELLIKNIGHT ACCESSORY Model SDSOO-ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight 5820 fire panel. The relay module must provide two Form C dry contact rated at 2.0 amps at 30 VDC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW CAUTION REMOVE POWER PRIOR TO SERVICING ~SILENT ~KNIGHT 4-7/8" 0 0 0 ~ 1/4" 1" Model SDSOO-ARM Addressable Relay Module Demensions <I!) SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350042, Rev. 11/97 Copyright © 1997 Silent Knight LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0559: 132 Misc. Devices/Control Unit Accessories Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact Brian Foltz (763) 493-6400 *FAX (763) 391-5464 Page 1 of 1 Models SDSOO-FRCM, SDS0O-FRCM-4 Monitor Modules and Model SD505-ARM Relay Module. Models SO500-ARM, SO500-AIM, 5D500-MIM Addressable Input Modules. Models 5D500-FRCM and SDS0O-FRCM-4 monitor modules provide Inputs for a control unit communication circuit and one Style B (Class 8) contact closure initiating device circuits. Models SO505-ARM and SO500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SDSOO-AIM and -MIM provide additional input circuits. · Refer to llstee's data sheet for addltf on al detailed product description and operational considerations. SDSOO-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC S0505-ARM: 120 VAC, 30 voe In accordance with listee's printed installation instructions, applicable codes & ordinances and fn a manner acceptable to the authority having Jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7300-041 O: 145 •Rev. 05-27-2004 This listing is based upon tecmical data submitted by the applicant CSFM Fire Engineeri~ staff has reviewed the test result& andlor other data but doe• not malot an incfe~ndent wrifioation of any daime. Thie lieting ie not an endoreement or recommendation of the item listed. Thia listing should not be used 1D verify correct operational requirements or installation aiteria. Refer to lime's data sheet. Installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 9, 2005 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2006 --=---==---..,._,..------ INTELLIKNIGHT ACCESSORY SDSOO-PS and SDSOO-PSDA Addressable Pull-Station lntelliKnight1s addressable pull stations combine fast response with pin-point location ID. The SDS00-PS and SDS00-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SDS00-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SDS00-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight -easy installation and stable operation -and it adds up to a flexible solution for all your fire protection needs. Model SDSOO-PS & SDSOO-PSDA Addressable Pull Station The SDS00-PS is a single action addressable fire pull station, and the SDS00--PSDA is a dual action addressable fire pull station. The SDS00-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SDS00-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SDS00- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals -accept up to 14 gauge wire • Extremely easy to operate • Corrosion-resistant gold-plated contacts. • Reflective label makes it easier to locate in low light Operation The SDS00-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SDS00-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: Standby Current: Alarm Current: Ambient Temperature: 24VDC .55mA .55mA 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB ® SDSOO-PS SILENT KNIGHT INTELLIKNIGHT ACCESSORY SDSOO-PS and SDSOO-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. 0 C==:J 0 .... ' ' ' ' ' ' ' ' ' ~ R ' '~ ' "' t'i, ' ' ' ~ ' ' ' ' 0 ~ C==:J a) Mounting to Single Gang Electrical Box Mounting to Optional Surface Mount Box y y 5D500-PSDA Installing 5D500-LK ® SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com 5-1/16" Wiring 3" 2-1/2" Dimensions Electrical Box must be at least 1-1 /2" Deep MADE IN AMERICA FORM# 350342, Rev. 09/02 Copyright © 2002 Silent Knight LISTING No. CATEGORY: USTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST ATE.FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-0559: 136 Page 1 of 1 Boxes/Pull Stations SIient Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Foltz (763) 493-6400 "FAA (763) 391-5464 Model PS-SKSA and S0500-PS fire alarm pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. 30VDC ln accordance with Ustee't. printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having Jurisdiction. Ustee's name, model number, electrlcal rating and UL label. Listed as fire alarm pull station use with separately listed compatible flre alarm control units. For Indoor use only. •Rev. 05-28-20CM Thia isting la baaed upon tedvlical data aubmiUad by1he applicant CSFM Fire Engineering staff has reviewed the test results andlor other data but don not maka an ~wet verification of artJ dam. Th'-\long • not an endol •ri•nt or l'900ffllnendation of the item lated. Thi• listing lhould not be used m verify correct operational reqwaments or installation atteria. Refer ID liatN'• data sheet. inatallation Instruction• and/or other swtable infonnation sources. Date Issued: Authorized By: MAY9,2005 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2006 LISTING No. CATEGORY: USTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-1653:163 Page 1 of 1 Audible Devices System Sensor, Unmco,porated Div. of Hone)IV"8U lnt'llnc., 3825 Ohio Avenue, st Charles IL 6017 4 Contact Trish Linhart (630) 3TT-6580 ext 1185 FAX (630) 377-7245 Models P1224MC, P1224MCW, P1224MCSP, P1224MCSPW, P1224MCP, P1224MCPW, P1224MCK, and P1224MCWK combination horn/strobes with selectable candela Refer to listee's data sheet for additional detailed product description and operational considerations. Electrical: 8-33 VDC/FWR 12/24 VOCIFWR 24VDC/FWR Selectable :15cd, 15ll5cd Selectable : 30cd, 75cd, 11 0cd In accordance with listee's printed Installation Instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These sounder/strobe combination units are not intended for field assembly. Ustee's name, model number, rating, and UL label. Listed as hom strobes for use with separately listed compatible fire alarm control units. Suitable for the hearing impaired application. For wall mount and indoor use only. Models with suffix •K• are suitable for extended indoor operation temperatures 32 to 150• F (0 to 66 °C) and have NEMA type 3R enclosure rating for outdoor use. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. Formerly 7135-1209:223 06-20-05 I This liating ia based upon tectvlical data submitted by the applicant CSFM Fire Engineering staff has reviewed the Int rnults andlor other data but doea not make an independent verification of any claims. This listing la not an endorsement or recommendation of the item listed. Thi• listing ahould not be used m verify correct operational requirements or installation critaria. Refer to lime'• data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 20, 2005 DIANE K. AREND, Senior Deputy Program Manager Usting Expires June 30, 2006 Models Available Strobes Red S1224MC S1224MCP S1224MCK S1224MCSP Horn/Strobes Red P1224MC P1224MCP P1224MCK P1224MCSP Horns Red H12/24 H12/24K Product Overview White S1224MCW S1224MCPW White P1224MCW P1224MCPW White H12/24W Operates on either 12V or 24V Widest range of candela options: 12V: 15 and 15/75 candela 24V: 15, 15/75, 30, 75, 110 candela Easy candela selection Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClick™ Synchronizable with MDL Sync• Circuit™ module Meets UL1971, NFPA 72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. @ ~ LISTED CS549V602NK17954 I S5512 CS549V702NK13751 '. S<OH ~ MEA ~ approved 7125-1209: 222 APPROVED 122-02-E 7135-1209:223 3014150 126-02-E SpectrAlert® Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced fea- tures that include the widest range of candela options available and the capability to recognize and self-adjust for either 12 or 24 volt operation. With an overall feature set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices provide both the innovation and efficiency synonymous with the SpectrAlert name. Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2-and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick,.M feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4" x 4" x 1 ½" back box or a single gang 2" x 4" x 17/s" back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync•Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model __ _ listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model ___ listed to UL 1971 and UL 464 and shall be approved for Specifications fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync•Circuit ___ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 41111 6" x 411116'' x 21/s" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Walk Test SpectrAlert horn/strobe and horn only work on "walk tests" with time dura- tions of 4 seconds or greater Weight, strobe and horn/strobe 8.8 oz. Voltages 12 or 24VDC and FWR unfiltered Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5" x 5 5/s" x 215/16" Strobe and horn/strobe with small footprint plate 3 3 / s" x 5 5 / s" x 2 5 / 1611 Horn with universal mounting plate 5" x 5 5/s" x 1 5/16" Horn without mounting plate 215/16" X 55/16" X 1 5/16" Weight, horn only 7.2 oz. Mounting 4" X 4" X 1 1/2'' or 2" X 4" X 1 7/s" standard boxes Indoor Operating Temperature 32°F to 120°F (0°C to 49°C) Maximum humidity 95% as tested per UL464 Operating Temperature Weatherproof ( horn and horn/ strobes) 32°F to 150°F (0°C to 66°C) ( outdoor strobe only) -40°±9°F to +151 °±9°F (-40°±5°C to +66°±5°C) ULC Canadian Models -40°C to 66°C Operating voltage range* 12V: 8-17.5V; 24V: 16-33V Operating voltage range* (with Sync •Circuit module, MDL) 12V: 9-17.5V; 24V: 17-33V *Note for Strobes: Do not exceed; 1) 16-33 or 8-17 .5 voltage range limit; 2) maximum number of 70 strobe lights when connecting the MDL Sync module with a maximum line impedance of 4 ohms per loop and; 3) maximum line impedance as required by the fire alarm control manufacturer U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 SpectrAlert Current Draw FWR Operating DC Operating Current-FWR Operating Current-Strobe Strobe Current-Horn Candela (mA RMS) (mA RMS) (mA RMS) Series Setting 12V 24V 12V S1224MC 15 112 64 127 Strobes 15/75 135 74 127 30 93 75 158 110 208 P1224MC 15 112 64 127 Horn/ Strobes 15/75 135 74 127 30 93 75 158 110 208 H12/24 Horns SpectrAlert Mounting and Operation Candela Selections For strobe candela selection, adjust slide switch located on the rear of the product while watching the viewing window on the side of the reflector. Permissible Candela Settings Candela Operating Voltage Setting 12V 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 24V 12V 24V 59 69 90 160 209 59 45.7 57.5 69 45.7 57.5 90 57.5 160 57.5 209 57.5 45.7 57.5 Selectable Horn Tones Temporal Low Volume High Volume Non-Temporal Low Volume High Volume DC Operating Current-Horn Horn (mA RMS) Audibility 12V 24V (dBA) 44.4 57 75 44.4 57 75 57 75 57 75 57 75 44.4 57 75 Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted 110 OK DIP Switch Operation OFF ON Factory Default DIP Switch A0133-00 Typical weatherproof mounting with universal plate rWBB A0120-00 Low Temporal Electromech. #8-36 x 1 /2" Flat Head 1•1 High l•I I Non-Temporal 1•1 3000Hz Base (rear) A0110-00 SpectrAlert Order·ng Information Model Description Model Description P1224MC Selectable Output Horn/Strobe, 12/24 volt, red H12/24 Horn, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt, white H12/24W Horn, 12/24 volt, white P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red, H12/24K Horn, 12/24 volt, red, weatherproof plain housing Accessories P1224MCPW Selectable Output Horn/Strobe, 12/24 volt, white, plain housing MDL Sync •Circuit Module, red P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, MDLW Sync •Circuit Module, white weatherproof MDLA Sync •Circuit Module, red, Canadian model P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, MDLWA Sync •Circuit Module, white, Canadian model "FUEGO" housing S-MP Small Footprint Mounting Plate, red, for single- S1224MC Selectable Output Strobe, 12/24 volt, red gang back box S1224MCW Selectable Output Strobe, 12/24 volt, white S-MPW Small Footprint Mounting Plate, white, for single- S1224MCP Selectable Output Strobe, 12/24 volt, red, plain gang back box housing BBS Surface Mount Back Box Skirt, red S1224MCPW Selectable Output Strobe, 12/24 volt, white, BBSW Surface Mount Back Box Skirt, white plain housing D-MP Universal Mounting Plate (replacement), red S1224MCK Selectable Output Strobe, 12/24 volt, red, weatherproof D-MPW Universal Mounting Plate (replacement), white S1224MCSP Selectable Output Strobe, 12/24 volt, red, WBB Weatherproof Back Box "FUEGO" housing Notes Agency Listings -Indoor models: UL, ULC, FM, CSFM, MEA. Weatherproof models: UL, CSFM (strobe only), MEA, ULC. All of these SpectrAlert products are designed for wall mount only. All weatherproof models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 www .sy stemsensor.c om System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.891920 Fx: 44.1403.891921 System Sensor in China Ph: 86.29.8832.0119 Fx: 86.29.8832.5119 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 © 2004 System Sensor. The company reserves the right to change product specifications without notice. System Sensor -Far East Ph: 85.22.191.9003 Fx : 85.22.736.6580 System Sensor -Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor -India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor -Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 A05-0325-004•10/04