Loading...
HomeMy WebLinkAboutPS 2019-0024; MCDONALD'S DRIVE-THRU MENU BOARD REPLACEMENT; Sign Permits/Programs (PS)DocuSign Envelope ID: 73F2E953-D241-4E7B-AADE-E9E5DA4405AB (city of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov b>tv' '2--o \ :)--oo ?.!, PLANNING ~I CATION# ?! 2.. 0 l J--~ 0 '2--q... REC'D BY ~ ~tf DA TE ~ / I I / / ) SIGN FEE ~£_;;6;.._7.~•;.._c::,_0 ________ _ SIGN PROGRAM FEE ________ _ RECEIPT NO. I ,207 °0 Z-:o I oa I 2 c2 o 14- NOTE: AN APPOINTMENT 15 REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. •SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: McDonalds Drive-thru Menu Board Replacemnet Address of Project: 5990 Avenida Encinas Assessor Parcel Number: 210-170-06-00 ------------------------ Related Planning Case Number(S): ____________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) (b9 Commercial (e) (c) Office/Industrial (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park U) Produce Stand (k) Nursery (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes []I No 0 Specific Plan Number PS 92-101 VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yes D No [19 SOUTH CARLSBAD COASTAL REVIEW AREA Yes O No 0 SIGN ORDINANCE: Yes O No [ii COASTAL ZONE: Yes []I No 0 P-11 Page 1 of 4 Rev. 02/28/18 DocuSign Envelope ID: 73F2E953-D241-4E7B-AADE-E9E5DA4405AB EXISTING SIGNS: TYPE NUMBER Pole Monument Wall Channels Letters/Arch 10 Suspended/Projecting Directional Canopy (to be replaced) 2 Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes [29 No 0 PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM TYPE NUMBER PROPOSED SIGN ALLOWED AREA Pole** Monument** Wall Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display 2 2 24 PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM TYPE NUMBER SIGN ALLOWED PROPOSED AREA Construction** For Sale** Banner Interim SIGN AREA SIGN HEIGHT 196.40 3' 78 6' Date 1-15-2013 PROPOSED MAXIMUM PROPOSED SIGN AREA SIGN SIGN HEIGHT HEIGHT 20 6' 6' PROPOSED MAXIMUM PROPOSED SIGN SIGN SIGN AREA HEIGHT HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02/28/18 DocuSign Envelope ID: 73F2E953-D241-4E7B-AADE-E9E5DA4405AB SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I l I P/L : Sight Distal\ce Requirement Show building/ s I I . . I I , I : I , ___ J Show setbacks from all curbs ---: : : ! I . I Show all property lines I . P/L : f I : • I . . curb line . I I ----------~--- • • Sight Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: 6461 sq. ft. --------- Tot a I Building Street Frontage: 125 linear ft. Total Signage Allowance: 264.75 sq. ft. Existing Signage (sq. ft.): 242.6 sq. ft. Remaining Sign Allowance at Present: ___ 2_2_.1_5 _____ sq. ft. Proposed Signage (sq. ft.): 40 sq. ft. Remaining Sign Allowance After Proposed Sign: 28.35 sq. ft. VILLAGE REVIEW AREA Total Signable Area: _________ sq.ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 DocuSign Envelope ID: 73F2E953-D241-4E7B-AADE-E9E5DA4405AB PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) Bill Gibb McDonalds USA LLC MAILING ADDRESS MAILING ADDRESS 3800 Kilroy Airport Way Ste. 200 9021 Rancho Park Ct CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Long Beach, CA 90806 562-216-0844 Rancho Cucamonga, CA 91730 909-208-1254 I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. i,.--QocuSigned by: 72qfo-(Ms ~f~rs 3/11/19 3/11/19 SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~ ~ Date: 1 lu I I 'l" ; J • P-11 Page 4 of 4 Rev. 02/28/18 G) SITE PLAN Scale: N.T.S 1-5 Exit Ramp prcpased Mating area (726 ~ I I ~ ii I , I ~-' I <p • ~Id's Restaurant 3800 sf proposed (46 parking stalls) 3800 sf existing rwwi-Wng -=--=· \ "-L~..LL'...L.L'...L<:..LCL.t.LiJ 9"-o· ' o· (I)!>) G]) . Existing directional to remain le Project McDonald's #7582 Address: 5990 Avenida Ave., Carlsbad, CA Account Manager: S.Janocha Designer: L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061.06 p Date: 06.20.12 Reg. No.: 218490 Revisions: R17/18/12LRNewe!e~ &site plan (1.75) • R2 7120/12 LR Now elevations (1.75) R3 7/24/12 LR New site plan (1.7S) R4 10/23112 LR New elev & site plan (1-75) . RS 10/24/12 LR Show cod canopy & opo (.75) RS Ol/08/lJ LR Show opo 3 menuboard (.75) •APPROVALS• FOR JOB CHECK Acct. Mgr. FOR CONSTRUCTION N;d.Mgr. Design Production FOR INSTALL ONLY N;d. Mgr. Page: 02 Ot 08 PATE DATE DATE Tlisls•ani,r.,l~dmi,gaulld llyS.,--Ellc:Mtal~lnc..lll :m-lor-lllPMI l lsnotlobt-a,ycno..-dy,x."'9"mlian.norlll lobtrapom,ed.a,plodo,11til:illdln"'1 llllion_ Thedw,gingolailan. .-. mollriab "' ___ ..,._ ... dos91 Ownn,Jpdtildlllg,lilholdby5"plrlor ElodblAdYoot,ing.tnc.-touso tildosignlnflfflltlionnuslblolilainodln WlitlgmnSl,porio,EledltcalAdvl!1!ing.ioc © SEA2012 -ThlCdrn dlpitlod hnn a i,..,i,te ~,.lcuimllnmoyVII"/ .-oalorspocllcalorls 63'-5"± G)-F~R_0_NT~E.;;l_EV_AT_I_0N_-...;N,;.;0.;,;,RT.;.;;H ..... _____________________________________________________ _ Scale: 3/32" = 1'-0" 63'-5"± '2'-R:-E"""':A __ R~EL~E~VA __ T_IO~N~--S0;..;U~TH ________________________________________________________ _ \!:I Scale: 3/32" = 1'-0" Project McDonald's #7582 Address: 5990 Avenida Ave., Carlsbad, CA Account Manager: S.Janocha Designer: L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061-06 P Date: 06.20.12 Reg. No.: 218490 Revisions: R1 7/18112 LR New elev. & site plan (1.75) R2 7/20/12 LR New elevalions (1 75) R3 7/24/12 LR New site plan (1.75) R4 10/23112 LR New elev & sile plan (1.75) R5 10/24/12 LR Show cod canopy & opo (.75) R6 01/08/13 LR Show opo 3 menuboard (.75) • APPROVALS • FOR JOB CHECK DAJI Acct. Mgr. FOR CONSTRUCTION DATE Acct. Mgr. Design Production FOR INSTALL ONLY Acct Mgr. Page: 03 Of: 08 DATE Tlislsanoriginollf1)Ubishe:llh\Wl00'Nlecl by Superior Elec~calAdveltl,i,g. Inc. llis Abmladlor)'OUl'approval Klsoottobethown lo ;ri)<ll!OMSll<i of yo,, o,g,rlzalian, nor ls I to be 11produced. a,plod m oxlibilod in any fashion 111, manging ol caon. .izes. malenals orllo<rinaloo melllod does not alter Ille doslg, Ownof>lip of lhis dos1gn Is held by Superior EltaicalAIMrf,ing, Inc -.rlon louse lhis desq, in any faslion n,J51 be obtaine<! in o,D,gfrom ..,eloctrlcalAdvel'islng. tnc © SEA2012 Nott: The Cdoil dl!l)lc:ted hero aro a !Taint ropnsenlalion Acklal color> may vo,y SH cXlbrr.pedllcallons 75'-8"± 1 \,•~•nt••=--•F1Mf ..,,,,,, 3 NON-DRIVE THRU ELEVATION -WEST r-::--:--:~~~-------------------------------------------S ca I e: 3/32" = 1'-0" 75'-8"± 111p,1,-., ]ll>Gf"W @~DR_IV~E~T~H~RU~E_L_EV~A_TI-ON_•....;EA=ST~------------------------------------------------------ Scale: 3/32" = 1'-0" Project McDonald's #7582 Address: 5990 Avenida Ave., Carlsbad, CA Account Manager: S.Janocha Designer. L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061-06 P Date; 06.20.12 Reg. No~ 218490 Revisions: R1 7/18/12 LR New elev & site plan (1.75) R2 7/20/12 LR New elevations (1.75) R3 7/24/12 LR New site plan (1.75) R4 10/23/12 LR New elev. & slle plan (1.15) RS 10/24/12 LR St-cw cad canopy & opo (.75) RB 01/08/13 LR Show opo 3 menuboard (.75) •APPROVALS• FOR JOB CHECK OAT£ Ace\. Mgr. FOR CONSTRUCTION DATE Ace\. Mgr. Design Production FOR INSTALL ONLY DATE Acct. Mgr. Page: 04 Ot 08 TNs b an original "1pli,lshod dr.iwi1g ctealod bySup,daEltcn:IIAdYeo1!si,g,lnc. Ills submillod for jlU appnml II ls 111I ID be shown ID ,nyone oolslde d yoor orgarlz>!ia\ nor ls II lo be relJl)dtlced. a:,pled o, oxNt;lod In any faslilon. The daogi>g d c:dcrs, sizes, mal!olals o,11\Jninalon melhod does not ale< tho deslg, Oomer,Np "111s doslQn 1s held bys~ EleciicalAdYerm,g,lnc -IOUSO ltis design In any fasNon IT<ISI be oblalntd n voting from Superior Elec!ricol AdYll1sing, Inc © SEA 2012 Nee The Cdon de!>i:t<d here are a~ "9"SOfUiion >asaiccknrr'J'fV1l'f s .. ailofspeciflc:alions ,. 16"-5" Tf'--::-LE_D--:IL-::-LU_M=-I_NA":"'.:T~ED::-C_H-:-AN_N':"""E_L L_ETT_E_RS_W __ IE_L_E_CT_R_IC_AL_C_H_A_NN_E_L _SU_P_PO_R_T _________ ......,,.;3.,;.2·.;..8 .;..Sq_ . .;.;.;Ft. l.!!.!.J Quantity: One (1) Required Scale: 3/8• = 1'-0" SPECIFICATIONS: LITTERS: RETURNS: ILLUMINATION: CHANNEL SUPPORT: POWER REQ: NOTE: INJECTION MOLDED WHITE POLYCARBONITE SILVER WHITE LED'S ALUMINUM CONSTRUCTION PAINTED SILVER 1.6 AMPS --j------------------16'-5" I 2'-0" IA21'i31~LE_o~1L~LU~M~IN~M~E~o_cH~A_NN~E_L_LET_T_ER_s ___________________ ~a2_.a~s~q._Ft. IA!!.I Quantity: Two (2) Required Scale: 3/8" = 1•-0• SPECIFICATIONS: LETTERS: RETURNS: ILLUMINATION: POWER REQ: NOTE: INJECTION MOLDED WHITE POLYCARBONITE SILVER WHITE LED'S 1.6 AMPS EXISTING STEEL 4" x 4"----.____ ' PAN HEAD SCREW '-, 4• RETURNS PAINTED SILVE ~ ' INJECTION MOLDED WHITE POLYCARBONITE LOW VOLTAGE WIRING FROM LED TD LEO ----, 318" X 3" LAG BOLTS MOUNTED TOP THROUGH -------~ FLAT BAR EVERY 4' -0" INTO WAU STUDS. s-xs· ELECTRICAL CHANNEL SUPPORTWITH REMOVABLE TDP-r---tih. CAP. DISCONNECT SWITCH MOUNTED ON END • . 063 ALUMINUM C-CHANNEL BACKS-r--- CLASS 2 LOW VOLTAGE WIRING-t--. 20/I. 120-277VAC DISCONNECT SWITCH-------- POWER SUPPLY-t----::;~t---.,.-::iall RUBBER BUSHING--IP:---..-----,.., LITTER ATTACHMENT TD SUPPORT-1--_,-'flµ=.:i;;;;i;:::51 #10 SHEET METAL SCREWS LIGHT EMITTING DIODES (LEOS)--!r----.i:t ONE (1) Y. WEEP HOLE BEHIND LITTER__/' LOCATED AT ALL AREAS THAT MAY COUECT WATER 2"x2"x3116" STEEL MOUNTING CLIPS 1-\" X 3W LAG SCREWS (OR EQUAL AS REQUIRED BY FIELD CONDITIONS) THROUGH FASCIA MATERIAi. INTO ROOFING SURFACE A1 TYPICAL SECTION DETAIL-ILLUMINATED LETTER SET / ELECTRICAL CHANNEL SUPPORT Scale: n.t.s PAN HEAD SCREW 4" RETURNS PAINTED SILVER INJECTION MOLDED ~ WHITE POLYCARBONITE LIGHT EMITTING DIODES (LEDs) ---r!----.t:IH LOW VOLTAGE WIRING FROM LED TO LED -11--~m 063 ALUMINUM C-CHANNa BACK ~1-----il-C DRILLED HOLE THRU WAU --1;----... FOR WIRE CONNECTIONS AND ALLEO WITH SILICONE TD PREVENT WATER PENETRATION THREADED NIPPLE AND COUF\.ING -,I..-!--"\ ~l I 20A 120-277VAC DISCONNECT SWITCH--l!--~►.11: FLEX (FLEXIBLE CONDUID / ___;11---~I--..J LIOUlll TIGHT CONNECTIONS #10 x 3 1$" DFIVE SCREWS --.t::::;;::J1-+-MINIMUM THREE {3) PER LETTER = OR AS REQUIRED PER FIELD CONDITIONS -t ONE (1) Y.-WEEP HOLE ___j LOCATED AT ALL AREAS THAT MAY COLLECT WATER POWER SUPPLY J.BOX WITH 120-277VAC DISCONNECT SWITCH PRIMARY POWER @2 A3~TY_P~IC_AL_S_E_CT_IO_N~O~Et~A~IL_-~IL~LU~M~IN~M~E~O~LE~TT_E~R;._ ____________ _ Scale: n.t.s Project McDonald's #7582 Address: 5990 Avenlda Ave., Carlsbad, CA Account Manager. S.Janocha Designer. L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061-06 P Date: 06.20.12 Reg. No.: 218490 Revisions: R1 7/1B/12 LR New elev. & site plan (1.75) R2 7/20/12 LR New elevations (1.75) R3 7/24/12 LR New site plan (1.75) R4 10/23/12 LR New elev. & sile plan (1.75) R5 10/24/12 LR Show cod canopy & opo (.75) RS 01/08113 LR Show opo 3 menuboard (.75) •APPROVALS• FOR JOB CHECK PAJE Acct. Mgr. FOR CONSTRUC110N DATE AcclMgr. Design Production FOR INSTALL ONLY Accl Mgr. Page: 05 Of: 08 DATE Tlisbonoriginallfllll.tlsl1eddmmgmiated by Superior Electica1Adl'l111s,,g. In~ Ills suwritted r« yoor appr1Mli II ls 110110 be shown lo M)<)flll outside of :,,,ur-nizatiu\ norlsM lo be ropnn.,cod. copied « oxNblltd In "1Y ra.Non The chatogcl!I of oclon. sizes, melerials otluminal!mmelhod does not alter !he deS9I 0-r>lip of !his design is held by Superior Eledrical Advtrt,ing. Inc Aulhorizalion lo usa t,s de,lgn In wry fasl'ion ....i be oblainod In wrilfng from SuperioJ Eladrical Advert,ing. lno. ©SEA2012 Ndo, Tho ColoBd'1)icfod htnaroa !1"flhlt ,.._....,1,11on, A<:W cota, may v,ry See Dllor spedllcab,s !81 !ljiil2 LED ILLUMINATED CHANNEL LOGO 14.0 Sq. Fl IJ!AJ~a~ua::n:-:;-tity::-:-:-:: S::-:e--ve::n-:(~7)~R::-:e"'."'qu"'.":'ir--e~d ....... ,_,.. ___________________ ..,S,..c-al-e:_1.;.,/2;.;;";.,;=;.;1~'-;.;0" (U]~ ~[g] ll1] SPECIFICATIONS: LOGO: RETURNS : ILLUMINATION: POWER REO: NOTE: INJECTION MOLDED YELLOW POLYCARBONITE SILVER WHITE LED'S 1.3 AMPS 4" 4" RETURNS PAINTED SILVER / I i PDLYCARBONITE FACES CHEMICALLY WELDED\.-.....,.,=="'='!'=as.J TO OPAQUE MODIAED ACRYLIC RETURNS ·, ......... WITH SMOOTH EDGES LIGHT EMITTING DIODES (LEDs) --11---.i-11:1 LOW VOLTAGE WIRING FROM LED TO LED --li----+11111 .063 ALUMINUM C-CHANNEL BACK --1!----t-!I~ EDGE DETAIL PRIMARY POWER --tt----::""'11ff-+--, SELF-CONTAINED POWER SUPPLY --- 1 20A 120-277VAC DISCONNECT SWITCH THREADED NIPPLE AND COUPLING #10 x 3 ½" DRIVE SCREWS MINIMUM THREE (3) PER LETTER OR AS REQUIRED PER FIELD CONDITIONS PAN HEAD SCREW --!!---.. ONE (1) ¼" WEEP HOLE _.=I LOCATED AT ALL AREAS THAT MAY COLLECT WATER TYPICAL SECTION DETAIL -SELF-CONTAINED BUILDING LOGO Scale: n.t.s Project McDonald's #7582 Address: 5990 Avenida Ave., Carlsbad, CA Account Manager: S.Janocha Designer: L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061-06 P Date: 06.20.12 Reg. No.: 218490 Revisions: R1 7/18112 LR New elev. & s~e plan (1,75) R2 7/20/12 LR New elevations (1.75) R3 7/24/12 LR New site plan (1.75) R4 10/23/12 LR New elev & site plan (1.75) R510/24/12 LR Show cod canopy & opo (.75) R6 01/08/13 LR Show opo 3 menuboard (.75) •APPROVALS• FOR JOB CHECK QAJE Acct. Mgr. FOR CONSTRUCTION DATE Acct Mgr. Design Production FOR INSTALL ONLV DATE Aa:J..Mgr. Page: 06 ot 08 llisllai011gil11..-,..,dnl,,i,gaulld bySi,penar 8oc:ttcai~ 1n1:. lls ll.blilldlcr,.ulllll0¥al llleot1Dbl._ 1o..,..,...-olyourGIPml<Jl.norlsl ID bl~ "'lllod«-ln flff -lhocta,gi,gdcdtn.-,,,_ .. ---nol-lltdosl!,1 OwnlnNpdlD11"'91 itheld t,ys.pnr ElodrlcalAd,ortslng.trc-lDuse IDcll'91lnanyfmllionnaatblablllnodln ~-Supellar-~lllo © SEA2012 __ lhoCcmrsdflliclld---•~ --..-cdorl,uy""Y Seocolarspociblarw • r t 4'-6" -----1- +- (]] NON-ILLUMINATED FREESTANDING FLAT CUT OUT LETTERS Quantity: One (1) Required SPECIFICATIONS: 3.0 Sq. Ft. Scale: 1/2" = 1'-0" • LETTERS: • RAIL: FLAT CUT OUT ALUMINUM PAINTED BLACK W/GREY VINYL INSET ALUMINUM PAINTED BLACK MOUNTED TO AWNING SUPPORT WITH 1/4 -20 SELF DRILLING SCREWS FOUR (4) PLACES 1 • x 1 • Steel Angle with ¼• Plate 2'-10" 3'-0" 10• T SINGLE FACE NON-ILLUMINATED WINDOW POSITION PANEL W/MOUNTING BRACKET 2.49 Sq. Fl L.£...J Quantity: One (1) Required Scale: 1" = 1'-0" SPECIFICATIONS: • 1/8" PAINTED ALUMINUM WITH VINYL OVERLAY • TWO (2) STAINLESS STEEL S-HOOKS AT TOP SO TO CONNECT TO EYEBOLTS ABOVE • PANEL: GRAY • COPY: WHITE • MOUNTING BRACKET: 1" X 1" STEEL ANGLE AND PLATE PAINTED BLACK 1" x 1 • Steel Angle _ ..... with¼" Plate 2'-10" ------..- I I -- Pick Up Here 3'-0" I 10" -+ I m SINGLE FACE NON-ILLUMINATED WINDOW POSITION PANEL W/MOUNTING BRACKET Quantity: One (1) Required SPECIFICATIONS: • 1/8" PAINTED ALUMINUM WITH VINYL OVERLAY • TWO (2) STAINLESS STEEL S-HOOKS AT TOP SO TO CONNECT TO EYEBOLTS ABOVE • PANEL: GRAY • COPY: WHITE • MOUNTING BRACKET: 1 fl X 1 fl STEEL ANGLE AND PLATE PAINTED BLACK 2.49 Sq. Fl Scale: 1" = 1'-0" Project: McDonald's #7582 Address: 5990 Avenida Ave., Carlsbad, CA Account Manager: S.Janocha Designer: L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061-06 P Date: 06.20.12 Reg. No.: 218490 Revislons: R1 7118/12 LR New elev. & site plan (1.75) R2 7/21¥12 LR New elevations (1.75) R3 7/24112 LR New site plan (1.75) R4 10/23112 LR New elev. & site plan (1.75) RS 10/24/12 LR Show cod canopy & opo (.75) R6 01/08113 LR Show opo 3 menuboard (.75) •APPROVALS • FOR JOB CHJ&K ll!Il AcclMgr. FOR CONSTR!.!£T!5ZN DATE Acct. Mgr. Design Production FOR INST!!:!, 211,Y (?ATE Acd. Mgr. Page: 07 Of: 08 TNslsanorl!ila~ lhwngaulld t,ys.,!ore.c.talAd""""'9,lnc.Kls -fcrY<UIPP'O'III llsncllDbolhown ID--d yo.r~ nor ls l 1Dbo.-_a,pec101-lnftlf r..tian Tho~dlDCn._,_ 01---ncl-hde!i!,\ o.n..Npol .. dts9'ilheldby&4'ft' Ellcllcal~.tnc.-lDuse Nsdlsi!l>lnfffflnlialnmlbe-.cll> WID,gtan~-AIMrtslf19 Inc ©SEA2012 -ThoColcndepclldhn .. ,~ ~ Aculcdorsmay'ill'f Soocdor$jlldllcalol1o . l J1 □ 10'-10" 9'·7" CLEARANCE SIIM One (1) Uni! R■qul,.d N W'------+- IQ) IE H \V/@ 'i' 1F lID U' M Clearance 9 Feet .I P TWTPI --p ;;w 1 ACM Cladding • Alucoband 'Bone White" Metal Base Enclosure Benjamin Moore "Deep Caviar" #2130-20 6" Tall Curb -L , . ..--r- 9'-11" To Pavement ** ALL FOOTINGS BY THE GENERAL CONTRACTOR ** (for signs on this page) 9'-4' canon 8'-8 • break-away clearance arm 1• H I I 'l I I I I 1 1 o I I 6'--0 1/4 • exlruded / bar i 15 •QIIDEB HEll" CANDPT WITH INTEGRATED COD Two (2) Unlls Roqulrtd .1-I r-1½• !-©wHw@ 9 JLIDlU'M Clearance 9 Feet 1 ·~--=--=----'- 9'-0" To Pavement ACM Clldllag • AllcGballd ·Beu Wli1I" Metal laH Encloare Betjlmlllllloare 'Deep Cnill" #2130-20 6" Tall Curb □ T 10'-111" 9•.7• I " 7'-0 . I • Iii ~ • 2'-3 . Seal■: N.tS. GATEWAY CllilWICE IAII lllllE NCI 111111-lW_.TD IOUMI 811 lcae:N.tl. On■ (1) UnH Requlrld Ont (1) Unit ......... • PMS 109 yellow reflective message panel with black decal graphics/letters lak:N.ts. Project McDonald's #7582 Address: 5990 Avenida Ave., Carlsbad, CA Account Manager: S.Janocha Designer: L. Ramirez 3.50 Scale: AS NOTED Design No.: 12-06-5061-06 P Date: D6.20.12 Reg. No.: 218490 Revisions: R1 7/18112 LR New elev. & sile plan (1.75) R2 7/2<Y12 LR New eleYations (1.75) R3 7/24/12 LR New sile plan (1.75) R4 10/23112 LR New elev & site plan (1.75) RS 10/24/12 LR Show cod canopy & opo (.75) R6 01/08113 LR Show opo 3 menuboard (.75) •APPROVALS• FOR JOB CHECK DATE Acct Mgr. FOR CONSTRUCTION DATE Acct. Mgr. Design Production FOR INSTALL ONLY DATE Acct. Mgr. Page: 08 Of: 08 This Is an Dlfgrlal tqlllbished ckavmg ttoale<I by Superiof Eleaical Ad~ R-Ills subm111edbjl)Ur appro,,ai fthoollllbe"10WTI la 1>1yoru, aublde cl yo<K o,garlzaior. no,)! l tabe rljlro<!Ucod. copied at u!,lijledln -arrt fashion Tho ~i,g of 0lkn, sizes, malerials or llurrinallon method dou rd alter the deslg, o..nenNp rl ... dosign Is held by Superiof ElodricalAdvartising. Inc. AIIU\crtzation tause llis deslgn 1n..,.,, fashion rr<J>I be obtained ii wrillng rn.n Superior Eledrical AMrlslng, Int ©SEA2012 No!~ The Cdor> depided here are a !1"plic "'"1serution.Atwlcoknmayva,y Seecolor'!)ldllarions 0 < m ?; r r en =1 m -0 ► z (/J ~ ~1 II 9 'Gl WWNo 0 ~o i; i ~ OJ • • I I I I I I en I!'> r I I -'I ,.,, I I u I )> I ,...... I 0 .$'." )> I :::0 I )> I :::0 u 0 I I :::0 -j :::0 0 )> 0 I' I I I I I I I I I I I ;1 i' ,-..; I :: I j ~8) I I ~ a; z I G) I~ ~ -0 . ~ ~ 0 ...... ~ ~ 1 .. o..: o : -"' . -+· ~ .:... ·~ ~" / '\,'\,?.i .,, .,, <;)\,"/ r.c;_'\. ,,_,,/ I,'> ::✓ ' ........ ---~' -----=::: --· co 0 AV[NfDA EN!CiNAS --~.--------:::----;;.G~ -I I ~ L) co co 1" ' I ,~ .., ,,.,, "' 1:::;1 ,~ I I I , ~========== =- fltJHl :JA/tJO 0 fltJHl :J,1/tJO 0 u .. .. [@ ~ 'z rnJ I~ ,~i ' I,.,, lLJLlLJL_Jl__Jj_JL___u_~:-~-,----e.._,I ~ ,-+J □: ~ " ' \ I I I 90•-,· fT7 X (j) ---j C) ~~ ~ ~ 0 0 ~ ., ~ w 0 z )> ' 0 (j) ~ L I I I I 1:-' <O 1"'. i===/ I ~=== :===========::::' I 1==I ,JI I ~ --------__ 68.J4• -------N 45• -- 42'14" -------[ -- --------- -~ff ~ 92' ====-t-1 1'43'25" ( c:::~ I I fil 3 ~ ;,;; z C i 0 en =1 m -0 ► z naid's .:cb,1 bad STD 155:: "'" m McDonald's USA, LLC 1 2 1 0 Th ... :'lllfng, ond apecH1caUon1 or• thl conrid-,itlol ond proprltitory ,•,L.gnur.l REV DAT£ 00MB MENU BOARD LAYOUT SH£ IV 1 · SITE: ADORtsS 00-4-1210 5990 """riido El'IC1t'l(IS, Corlsbod, CA 92006 RCV1CW£D BY prop.,;y Qf McOonokl'e US4. LLC ond lholl not ~ cQflMtd « ,..-v,du<:ed without writt,n outhorb:aUon. TM c;onll"oct document.I w..-. pr.por.d for IJff on th'-1p.c:lfic llil• In conjunction with ita \Hu. dab ond ~ a.-rr 1ssvm not suitable fOf' UM on a diffllfWlt ,it, or ot a later tim,. u., of J/5/19 !:9r!:,:ruo~~ r.i~= :Ch~:C"r:'!.: :;!~~-proA:.=t= ::r the controct documenla for rlUN on onother project le not oulhoriied. PLANNING ANO DESIGN 12832 Valley View Street I Slite C I Garden Grove I CA I 928-45 Phone 11•.892-3900 I Fax 71-4.892-394• .. t ~ CJ 0 1 c::=::::::::.: :i ►~~ )> ,, :;:a O<"'U ~ C~m r;;: "' >Gl-<o ~ r ffi~~~ .... m C/J m r;;: \2 en ! G') 0 )> ;gffi ~ 0 r 6(/J"' -0 0 ~ ~ m m 0 en ;o ;;:: "Tl 0 w m ~ ;:o ~ z 'u C ;o w -I 0 ~ ;:o 6 ~ ;o ;,;; z 0 0 ;o (/) ~ ~ 0£SCRIPTION OY .• MENU BOARD LAYOUT SCALE: 3116"=1'-0" GENERAL NOTES 1. DRIVE--HRU El EMENTS: COD. DRIVE-THRU PYLON/CLEARANCE POLE AND BOLLARD SIGN SrALL BE CONSISTENT WITH THE STANDARD BUILDING DESIGN DRIVE-THRU ELEMENTS. OTHER DESIGNS MAY NOT BE USED. " CONTRACTOR SHALL COORDINATE WliH APPLICABLE PLANS, McDONALD'S AREA CONSTRUCTION MANAGER, CONTENT SUPPLIER ANO SIGNAGE SUPPLIER TO DETERMINE EXACT LOCATION, ORIENTA.Tl()N. MOUNTING HEIGHTS, ANO NUMBER OF BO.&.ROS ANO OTHER ORJVE-THRU ELEMENTS TO BE INSTALLED AT iHIS SITE. ALL WORK TO BE COORD NATED WITH OTHER TRADES. J. CONTACT McDONALD'S AREA CONSTRUC70N MANAGER FOR ORIVE-THRU ELE~ENT FOOTING ANO WIRING REQUIREMENTS NOT S1--0'NN. (l~FORMATION ALSO AVAILABLE ThROUGH VENDOR NEBSITES) SIGNAGE WANUFACTURER TO PROVIDE FOOTING ANCHORS de. TEMPLATES TO G.C. PRIOR TO F"OUNDATION POURING. 4. SEE ELECTRICAL SHEETS F"OR DETECTOR LOOP DETAILS. 5. CONTRACTOR TO COORDINATE THE RESPONSIEJIUTIES or THE ELECTRICAL CONTRACTOR. CONTENT SUPPLIER AND THE SIGN SUPPLIER. 6. CONTRACiOR TO INSTALL PRE-FORMED. PRE-WIRED VEHICLE DETECTOR LOOP. 7. CONTRACTOR SHALL VERIFY CONDUIT SIZES REOU'REO SY VEHICLE LOOP DETECTOR SUPPLIER. SIDE BY SIDE DR IVE -THRU STANDARD 1.? 3. SIDE BY SIDE ORIVE-THRU STANDARD 1.2 EQUIPMENT PDSmONING FOR PRIMARY LANE· l}E] NOT USED ~ :~ g~~i~~ g~ :~ ~~~6u~i:~O~~~~ ~~~Nr~i>'°~~S o~O r~i i·,;;~:ROM MENU BOARD NOT BE LESS THAN 12· FROM FACE OF CURB. [gJ !~~l~R~~~ :~ ii~7io~~gu!f ~~ A;o~N ~~G~~THOFl~;R~;::i~y 35· L_ SIDE BY SIDE DRIVE-THRU STANDARD 1.2 EOUIP~ENT PcsmoNING FOR SECONDARY 16NC"· ~ ~~M c~=R06rTH~l~i~~~~YND~~NouN ~~o rt~utr%T~ ~~iHfEsEc5~~g;RY MENU BOARD NOT 3E LESS ThAN I 2• FROl.1 FACE OF CURB. [ill ~~ r5R~CJNf~REYH1~Ct0pa8s~~~E~H~¥l~i~~ ~:~~ii ~60:.p~~~:i:r::ELY NOTE: ® EXISTING EOUIPl.1E~T TO REMAIN @ NEW MENU BOARD SIGN SCHEDULE • McDONALD'S SIGNAGE NO. DESCRIPTION ILLUM. AREA QUANl'. A CHANNEL LETTERS y 32.8 3 B CHANNEL ARCH y 14.0 7 C D 'WELCOME" LETTERS N 3.0 1 E WINDOW BANNER N -1 F WINDOW BANNER .N .. 1 G MENUBOARD y ;,,o 2 H COD CANOPY .. -2 I J GATEWAY CLEARANCE N .. 2 K BOLLARD N .. 1 TOTAL SQ. FOOTAGE = TOTAL i 98A 9B,O I -.. - '$IC ! -. -' -~.,,,, ,. a, I'! ~ ~ ! -I ~ ;l J ~ H ;i Jt I c,-: cn.;u. i!l •-o"~ :.,t, ~}'~ !U 1' a t e ~ /, ~ ~ •' ~ •'-!. ~ 1' n a 'O C -5l I -= 0 u "' ~ C I .~ >-u ~ C w 0 ,.. g 0 :3 "' Ii C 0 "' er ~ ., 0 "' 0 a, q ~ C N ~ ~ C: -~ 0 J ~ m :,; ~ 0 u gd ~ -::i; -oDMB MENU BOARD .. DESIGN PARAMETERS: MATERIALS: 2016 CALI FORNIA BUILDING CODE GRADE F1554 GR 36 ANCHOR BOLTS ASCE. 07-10 GRADE A615 60 KSI REBAR WIND SPEED DATA 3000 PSI CONCRETE @ 28 DAYS 1. BASIC WIND SPEED = 110 MPH CLASS D SOIL: (3 S C. GUS T) r 2. WIND IMPORTANCE FACTOR 1.0 1,500 PSF SOIL BEARING 3. WIND EXPOSURE C 250 PSF /LF SOIL LATERAL BEARING 4. INTERNAL PRESSURE COEF N/ A UNDISTURBED SOIL 5. COMPONENT A D CLAD DING N/A UL LISTING : C o I c.o 0 L..() = . CXJ N 1/4" I n 0) I n HSS8X6X1,5 POST OR PER MANUFACTU ER'S 19"x12 .S"x5/8" THIC K BASE PLATE / (E) GRAD E H--+-( 4) ¾" DIA. x 24" LONG W/ HEAD OR NUT EMBEDDED -coNCRETE FOUNDATION (4) #4 O.C.E.W. MENU BOARD W/ SPREAD FOOTING DETAIL 20 SQ FT VP ENGINEERING LICENSE# C 57550 12832 VALLEY VIEW ST., #0 GARDEN GROVE, CA 92845 TEL: (714) 251 4537 Email: benphanconsultant@gmail.com ,._ a, I t ,z -~ ~ ~ ~ i ~ ~ ! ~ "O 0 D " "§ u " g ·.:; C w 0 "O ·2 " ~ Vl i:, _, "' z 0 0 u "' ~ ~~ !fE "0 ~N ~,!. ~ c!r!i I ~ i 0 ~ er .., ~ 0 (D ~ ::::, j z w g :::. ~ i 0 ~ N I -I 2 -q-~ 0 ~ 0 S-1 i SCALE: 3/4";]' NOTES: a) ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS ANO COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15" MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. b) CONTROL SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM TOP OF OUTLET BOX NOR LESS THAN 36" MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. a. LIGHTING STANDARDS REQUIRE A SEPARATE PERMIT. b. ALL SIGN REQUIRE SEPARATE PERMITS AND APPROVALS. c. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. ALL EQUIPMENTS SHALL BE U.L. LISTED AND INSTALLED ACCORDING TO THE LISTING ALL WORK TO COMPLY WITH THE 2016 CBC, CPC AND CMC AND THE 2016 CEC (201 4 NEC) WITH STATE AND LOCAL AMENDMENTS. CONDUCTORS ALL CONDUCTORS SHALL BE COPPE~ AS FOLLOWS: #12 AWG AND SMALLER -SOLID, THHN/THWN-2 #10 AWG AND LARGER -STRANDED, THWN-2, THHN OR XHHW ALL TERMINATIONS AND CONDUCTOR SIZES ARE BASED ON 75'C TEMPERATURE RATING GENERAL NOTES 1. REFER TO EQUIPMENT SCHEDULE FOR ELECTRICAL SPECIFICATIONS FOR EQUIPMENT PROVIDED BY TENANT OR OWNER. 2. ELECTRICAL CONTRACTOR SHALL FURNISH, INSTALL, AND , FOR THE COMPLETION OF WOPKS, ALL WIRE WAYS, CONDUITS, CONNECTORS, OUTLETS ETC ... 3. COMPLETE ALL ELECTRICAL WORK IN ACCORDANCE AND COMPLIANCE WITH ALL LOCAL,STME AND N.E.C. ANY MODIFICATION REQUIRED TO THESE PLANS FOR PROPER COMPUA.NCE SHALL BE THE RESPONSIBILITY OF THE ELEC RICAL CONTRACTOR. 4. THE E.C SHALL PROVIDE CIRCUIT DIRECTORY WITH A TYPED CIRCUIT DESIGNATION CARD UNDER PLASTIC COVER ON THE INSIDE OF EACH PANEL DOOR. 5. ALL EQUIPMENT SHALL BE U.L. LISTED AND APPROVED. 6. 7. ALL CODUIT RUNS ARE SHOWN DIAGRAMMATICALLY ONLY AND SHALL BE RUN TO SUIT CONDITIONS IN THE FIELD. ALL CONDUCTORS SHALL BE STANDARD ANNEALED COPPER TYPE THHN, THW, OR OTHERWISE AS NOTED. 8. EXACT LOCATION OF EQUIPMENT, SWITCHBOARDS, SUBPANELS AND LIGHT FIXTURES SHALL BE VERIFIED AT THE FIELD AND APPROVED BY OWNER OR ARCHITECT PRIOR TO INSTALLATION. 9. AL FLUORESCENT UGH FIXTURES SHALL BE ENERGY SAVER TYPE AND APPROVED BY C.E.C. 10. T rlE E.C. SHALL BE RESPONSIBLE FOR PROPER PHASING AND BALANCING OF ALL CIRCUITS. 11. ALL CONTROL WIRING FOR A/C , HEATER, AND COMPRESSOR SHALL BE RATED WITH MINIMUM SIZE # 14 COPPER. 12. ALL WORK TO COMPLY WITH THE 2014 NEC. & 2016 C.E.C. 13. LIGHT FIXTURES IN CONTACT WITH INSULATION TO BE U.L LISTED FOR THERMAL BARRIER OR WITH 3" MINIMUM CLEARANCE. 14. ALL HOME RUN J-BOXES SHALL BE IDEN IFIED WITH PANEL DESIGNATION AND CIRCUIT NUMBER. 15. LIGHTS MUST NOT BE RECESSED IN FIRE RATED CEILING OF CORRIDOR UNLESS BOXED WITH EQUIVALENT CONSTRUCTION. 16. THE E.C SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS. 17. THIS ENGINEER ASSUMES NO LIABILITY OR RESPONSIBILITY TO ANYONE WHATSOEVER AS A RESULT OF ANY INACCURACY OR CHANGE IN INFORMATION GIVEN TO THE ENGINEER ON WHICH THESE PLANS ARE BASED. 18. THE E.C SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS PRIOR TO THE START OF THE JOB. 19. LIGHT SWITCHES SHALL NOT BE LOCATED BEHIND ANY DOORS OR EQUIPMENT. 20. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY AN APPROVED TESTING COMPANY. 21. A NEUTRAL FAULT TEST IS REQUIRED BEFORE ENERGIZING NEW CIRCUITS. 22. EMT CONDUIT IS NOT TO BE USED IN DAMP OR WET LOCA IONS UNLESS CORRISION RESISTANT PAINT IS APPLIED. 23. CLEARANCE IN FRONT OF "MSB" & PANELS MUST BE 36" MINIMUM. PROVIDE IN COTRASTING COLOR "CLEAN ARE" WORKING SPACE BOX WITH DIAGONAL LINES ON THE FLOOR OR LARGE STICKER ON FACE OF MSBAND SUBPANEL SYMBOL j $ ◄ <J D-' (J) s • UP o ON (E) (N) (R) (ER) (NL) ELECTRICAL SYMBOL LIST DESCRIPTION f-'OMERUN TO PANEL OR EQUIPMENT AS NOTED CONDUIT RUN CONCEALED IN WALL OR ABOVE FINISHED CEILING OR AS NOTED CONDUIT IN OR UNDER, OR UNDERGROUND, 3/4" MINIMUM SIZE. CONDUIT RU WI H EQUIPMEW GROUNDING CONDUCTOR, SAME SIZE AS CIRCUIT CONDUCTORS, OR AS NOTED. CONDUIT RUN WITH ISOLATED GROUNDING CONDUCTOR, SAME SIZE AS CIRCUIT CONDUCTORS, OR AS NOTED. BRANCH CIRCUIT WIRING, 2#12 IN 1/2" CONDUIT AS NOTED OR SYMBOLIZED --11.;½--' -1/2"C.-3 #12 --ll.17j1-,lfiW-!'-3/4"C -6 #12 --1»:rmW-1/2"C.-4#12 1½hW 3/4"C.-7 #12 __,,~,,_,y,,,..f/-3/4"C -5#12 liWlW 3/4"C -8#12 ELECTRICAL PANELBOARD, AS DESIGNATED, FLUSH OR SURFACE MOUNTED AS INDICATED LffiERED BALLOON INDICATING PANELBOARD OR EQUIPMENT DESIGNATION DUPLEX RECEPTACLE IN WALL, + 18" OR AS NOTED GFCI DUPLEX RECEPTACLE IN WALL, +42" OR AS NOTED TWO-GANG DUPLEX RECEPTACLE (OUADPLEX) IN WALL. + 18" OR AS NOTED DUPLEX RECEPTACLE (20 AMP) + 18" OR AS NOTED (ON A SEPARATE CIRCUIT) CFCI DUPLEX RECEPTACLE (20 AMP) +42" OR AS NOTED (ON A SEPARATE CIRCUIT) SPECIAL RECEPTACLE TYPE AS DESIGNATED, + 18" OR AS NOTED JUNCTION BOX, ABOVE CEILING, OR AS REQUIRED TO SUIT THE APPLICATION APPROXIMATE LOCATION EXISTING J-BOX IN ACCESSIBLE CEILING SPACE SINGLE POLE SWITCH, t 42" OR AS NOTED TELEPHONE OUTLET IN WALL, + 18" OR AS NOTED SINGLE GANG OUTLET BOX WITH 3/ 4" CONDUIT AND PULL WIRE TO ACCESSIBLE CEILING SPACE. DATA OUTLET IN WALL + 18" OR AS NOTED. SINGLE GANG OUTLET BOX WITH 3/ 4" CONDUIT AND PULL WIRE TO ACCESSIBLE CEILING SPACE. COMBINATION TELEPHONE/DATA OUTLET BOX, +18" OR AS NOTED. SINGLE GANG OUTLET BOX WITH 3/ 4" CONDUIT AND PULL WIRE TO ACCESSIBLE CEILING SPACE. DISCONNECT SWITCH, FUSED AS NOTED ON PLAN REFERENCE TO PLAN NOTES MANUAL MOTOR RATED SWITCH LOCATED @ EQUIPMENT CONDUIT STUBBED UP CONDUIT STUBBED DOWN DENOTES EXISTING TO REMAIN DENOTES NEW TO MATCH EXISTING DENOTES EXISTING RELOCATED DEVICE AT NEW LOCATION DENOTES EXISTING DEVICE TO BE RELOCATED DENOTES FIXTURE SHALL BE EQUIPPED WITH 90 MINUTE BATTERY PACK L4 ENGINEERING LIC. #E15596 12832 VALLEY VIEW STREET. STE.D GARDEN GROVE, CA 92845 TEL (949) 521-3092 Email. lanvnguyen@sbcglobal.net I:' is ~ ! I -< <.> -' 13 -i. I ~;;,; -'? u S: ~~ ' -: .. ~ ~i ~'? ,~ :il j ~Q. -0 0 .0 "' I ,:: 0 u "' ~ 0 1 C ·;:; ~ C w j 0 -0 'E ~~ ., i ~ ~ ~1 "' 0 ~I ::2 -0 ~~ C 0 0 I ~ 9§ ~~ iu ~t 0 ~ E-1 :'5 SYMBOL UST & NOTES 'ti ., (E) MAIN SWITCHBOARD 'MSA' ~~~CRtmYtD AIC= 65,000A OR 881.9 A (E) 1200A I 120/208V-30-4W I TOTAL CONNECTED LOAD = 317.5 KVA I _______________________ J __________________________________________________________________________________________________________ _ _ GNO BUS I I ' , (E) 200,.\ 3P 1, . (E) • )60A [ 2P 1200A BUS i, (E) ... -200A 3P : . _(E) , )200A ' 3P I' (E) .,. :200A 3P ' '(E) ,. i 125A .. 3P \,,(E) . /30A r 3P \ ,(E) • )30A ' 3P 6, (E) i30A 3P : .. (E) • )70A • 3P J '(E) i30A ,. 3P I --------------rr-_ _L _____ _ i _r-(E) GROUND ---------- (EXISTING PANELBOARD) PAr-EL: LP LOCATION: KfTQ-IBII MOUNTING: RECESSED 0 VA LOAD z f--'T"'-~--i 5 A s I c +-=-(E) GROUND ! =-EXIST. SERVICE . ' ., FEEDER PA1'8..VOLTAGE: BUS: 120/208 3P. 4W 250A M'IIN: ML.O. Ct'. w 0 w W i ...... sl (E) PANEL 'LP' 29.5 KVA 106.4 A AIC RA TING: 65.000A Sffi!ES RA TED Ct:: 0::: 0::: 0::: a::: w w w w w a:: 8 8 8 8 8 W' LL ~ t: ~ ~ I:= LL f:i f5 ~ § ~ SI sl !:::, S; Si ~ S: ~ ~ ~w ~w; LL (E) (E) PANEL PANEL •cp· 'p' .... 9.4 KVA 36.3 KVA 42.7 A 124.1 A \ (E) (E) (E) PANEL PANEL K1 'AP!' 'AP2' 25.6 KVA .. -71.0 A 49.3 KVA 47.5 KVA 137.0 A 132.0 A ..... ._ -g: ........,! -~--(E) (E) D1 CENTER ISL.AND PANEL 25.6 KVA 71.0 A 34.2 KVA 95.0 A I (E) (E) CLAM GRILL CLAM GRILL 9.9 KVA 27.5 A 9.9 KVA 27.5 A NO WORK IN THIS PANEL/EQUIPMENT NO CHANGE IN LOAD 278.6 KVA (E) i (E) (E) ICE ' ICE l ICE MACHINE ; MACHINE ; MACHINE ----.. ···-···•-···· 5.4 KVA 5.4 KVA 5.4 KVA 15.0 A 15.0 A 15.0 A -;~-E: N_l~_T_I N_G_S_I_N_G_L_E_L_IN_E_D_IA_G_R_A_M----!0 (EXISTING PANELBOARD) 0:: w 0 w w ..... (E) P-1 ---- 17.6 KVA 49.0 A I Ct'. w 0 w w ..... (E) TVSS ···--·--------------· 6.5 KVA 18.0 A CIRa...lT CODE: N : IION-CONTIIIIJOUS L : LOr-K;-CONTN.JOUS PANEL: CP Locanon: KITCHEN M:>unang: RECESSED PANELVOLTAGE: 120/208 1P,3W BUS: 60A CIRCUIT CODE: N : NON-CONTINUOUS L : LONG-cONTINUOUS R DEM<\~BLE RECEPTAQ.E5 K KfTQ-IBII MAIN: 60A R: DEMANDABLE RECEPTACLES AIC RATING: 65,000, SERIES RATED K: KITCHEN LOAD DESCRPTION ~ TYPEO'i'T. C.8. BUS C.B. TYPEO'i'T. ~ 8 M R L TR P ABC TR P L R M 8 LOAD DESCRIPTION 0 z t--A-~-8~-C--<I;; CJ VA LOAD ~ !TYPE CNT C.B. BUS C.B. TYPE CNT ~ 0 VA LOAD z LOAD DESCRIPTION 8 M R L TR p A B TR p L R M 8 LOAD DESCRIPTION ~ A B u 1 500 VA LOAD A 600 0 z B ~ u CD-2 I l-'-(E)~PO_v,1,R __ LN< ____ --,t--t-+-+--+--,t--tX SPACE X SPACE 2 4 ~ f-CD 3 800 (E) D/T TIii.ER N 20 1 X 20 1 N (E} POS 1-=t---+--==-+-c=E);-,P,..,o""s,.,P""R""Ec:P""L""IN""E~---+--t--,t--+-+=2-=-o+-,1-i X -20,-+71 +-+--+--+N,.,+(':Eic} P:,o""'s""s""'E"'R""v""c""N""T,:Rc,D"'!T=--+----+--=-=--+"'7'1 600 2 kD 4 1 5 I ",~ (E) PARKING LOT LTG L 20 2 X 9 1...1..:2c:.oo'-+-I -+·---_---------+--+--,t--+-+--+--,-; 11 I 1200 (E) PARKINGLOTLTG L .. - L 20 2 "i3!1200l t---+.~ .. -. --------+-+--+-t--+--+-, L .. .. X 15 1...1..:20c:.o.;..+-l -+<""E)'-EXTERJO=~-R_s_1G_N ___ -+--+--,t--+-+--+--,-; 17 l,__500_+<~E)~DIRECT10 ___ NA_L_S_IG_N __ -+-+--+-t--+--+-, "'i9115C07 (E) SHOW\MNOOW REC. L 1 20 1 L 20 1 L 20 1 X 21 L....:.90'-'0'-+-l-+("'E)'-ROO'-'-'-F_RB::_. ____ -+--+--,t--+-+,-t--,-i '23 I SPACE 2511 t---+S-PA-CE-------+-+--+--+--+-+--< R 20 1 20 1 20 1 X 21 1.....:.60"'0'-+-l-=<E)'-CO-'--UNT __ ER_r..ENUl __ o_A_RD_-+--+--,t--+-+--+--,-; 29 I 540 (E} ONr-K; AREA LTG L 20 1 L 36 20 1 3111zool ,___+(c.E)~R-'A-::RKcclccNG-:-,-LO=-:T=cL-::T:::G---,-:-+-;-1---t-::-=c+-::-1 L 20 2 X 33 L..:1200=+-1-+·----·--------+--+--,t--+-+--+--,-i 35 I SPARE L .. - L 20 1 37l2107 t---t,(=E)-::RE5=TROO==-=-:M-:cL-::T::::G---r.-t-t-+-:+-::-:c+-:-'1 L 14 20 1 39 1.....:.8=.:80'-+-l-=<E>;:..;:.;ST-'OO</--s_UPFQ __ RT_L T_G_-+-+--,t--+-+--+-,-; Ti I 500 (E) EM+"'- L 20 1 5310 59801 2740 A-IASETOTALS Total Fhase A: 9230 >-----------< Total Fhase B: 10480 Total Fhase c,1---------9::::7:-::-20:1 L 20 1 X X 20 1 20 1 X 20 1 X 20 1 20 1 X 20 1 X 20 1 20 1 X 20 1 X 20 1 20 1 X 20 1 X 20 1 X X 20 1 20 1 X 20 1 X 20 1 L (E) KITCHEN LTG ~~ 1 L (E) KITCHEN LTG 720 8 (E) EXTERJOR SOFFfT LTG 600 10 (E) EXTERJOR SOFFfT L TG ~...!! L (E) EXTERJOR SOFFrT LTG 600 14 L ( E) EXlERIOR SIGN 1200 16 L (E) EXlERIOR SIGN ~~ L (E) SEOJRITY C'A MERA 500 20 L (E) DINING AREA REC. 900 22 L (E) EXTERJOR SIGN ~~ L ( E) ROAD SIGN 1200 26 L (E) EXTERJOR SIGN 1200 28 L (E) KfTQ-IBII LTG SPACE SPACE L (E) FREEZERLTG L (E) TRASH CXJMPACTOR 900 1 L EXTERJOR !IENUBOARDS 600 L EXTERJOR l'.ENU8OA RDS A-IASE TOTALS 3920 4500 CX)t>N:C'TH) VA (CXJDE N): CXJNNECTcD VA (CODE L): CX)t>N:C'TH)VA (CODER): CX)~VA (CXJDEK): TOTAL CONNECTID KV A: DEM'lr-D KV A: ~~ 32 34 ~36 38 40 600 42 6980 27330 900 29.5 TOTALADJUSTEDKVA: 29.5 TOTAL PANS.. Al.f'S: 87.4 AM'S W/LCL: 106.4 CD DE OTES EXISTING CIRCUIT BREAKER TO REMA! ; ALL OTHERS ARE NEW TO MATCH EXISTING, TYPE AND AIC RATING. I 5 540 7 ---=+---+---+<=cEc,) P,.,o~s~------+-N-+-+-+--+-2_0-+-1--1 X f-=,20,-+..,.1 +--+--+-1-+N,.,+C=-O:,D,-..,.J-8=0-=-X~#~1~----+----+--=-=--+~ SPACE 1 N COO J-8OX#2 X 20 1 600 600 6 8 I 9 540 (E) PCS N 1 N MENUBOARD #1 (i}-+ 1 11 540 (E) POS N 1 N MENUBOARD # 1 13 540 (E} PCS N 1 N MENUBOARD #2 f,.,1,.,5+-5=-4"'0-+---+-(=E};-,P,..,o""s~-------N+--+--+-+=+c-i 1 N MENUBOARD #2 20 1 X 20 1 20 1 X 20 1 20 1 X 20 1 20 1 X 20 1 600 600 600 600 10 12 14 16 17 SPACE 1 N PRESELL X 20 1 600 18 2120 1880 PHASE TOTALS PHASE TOTALS 3000 2400 Total Phase A: 5120 >-----------! Total Phase B: 4280 t----------~ CONNECTED VA(CODE N): 8600 CONNECTED VA(CODE L): 0 CONNECTED VA(CODE R): CONNECTED VA(CODE K): TOTAL CONNECTED KVA: 9.4 DEMAND KVA: 0.0 TOTAL ADJUSTED KVA: 9.4 TOTAL PANEL AM'S: 42.7 1/24/17 11:00 PM AM'S WILCL: 42.7 CD DENOTES EXISTING CIRCUIT BREAKER TO REMAIN; ALL OTHERS ARE NEW TO MATCH EXISTING, TYPE AND AIC RATING. L4 ENGINEERING UC. #E15596 12832 VALLEY VIEW STREET. STE.D GARDEN GROVE, CA 92845 TEL (949) 521-3092 Email. lanvnguyen@sbcglobal.net 1 ? :So..; u !J1:o!aj -p•ux·i~~ ...J ... ;..=~ !10 ...J ~~r8•Ui <( ;l;!~t.: i~!~il!f rn ~~it~§t" ~ ::::> 3 C O 8 .. 11u~.i1 II) ~ .. tlilj; ~ :l~§d~1 j~~.,hh ns C: ]~f~"~l; 0 l;FiU~ C ~ I l · ~1 CJ •A. ~~x :!!: :;.~;il •~'O 1 ~t .~r~] • ~i-:1~-1 E a•• =I· Hi~H:~ ~ " ~ !~ t ~ ~ I ~ 'a~ ' ~ le~ I ~ " 'O 0 ~ I 'C 0 u "' ;S 0 l C ·u ~ C w l 0 'O I~ 'E ., > <( ' "' 0 q 'O ~ 0 ~ ~ C 0 0 J~m ~ ~ 0 ~ u gd ~ 8 s ::, ~ E-2 ~ PANELS ~(N) 1--@)(E) 0EP:_,,_~ 0EP-~ _ SITE PLAN GENERAL NOTES 1. CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATING AND TRENCHING ON THIS SITE TO AVOID EXISTING DUCTS. PIPING OR CONDUITS, ETC., AND TO PREVENT HAZARDS TO PERSONNEL AND/OR DAMAGE TO EXISTING UNDERGROUND UTILITIES OR STRUCTURES WHETHER OR NOT SHOWN AND INSTALLED BY ANY OTHER CONTRACTS. THE ENGINEER IS NOT RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES WHETHER OR NOT SHOWN OR DETAILED AND INSTALLED BY ANY OTHER CONTRACTS. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER SHOULD SUCH UNIDENTIFIED CONDITIONS BE DISCOVERED. THESE DRAWINGS AND SPECIFICATIONS DO NOT INCLUDE THE NECESSARY ELEMENTS FOR CONSTRUCTION SAFETY. 2. CALL UNDERGROUND ALERT BEFORE YOU DIG. 1-800-227-2600. 3. ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. 4. MINIMUM CONDUCTOR SIZE SHALL BE #10 AWG. ALL UNDERGROUND CONDUIT SHALL BE PVC SCHED. 40. 5. ALL ELECTRICAL DEVICES/EQUIPMENT MOUNTED OUTDOORS SHALL BE WEATHERPROOF (NEMA 3R). 6. ALL FUTURE AND SPARE CONDUITS SHALL BE PROVIDED WITH A NYLON PULL STRING. 7. BURY CONDUITS AT MINIMUM OF 24" BELOW GRADE. PLAN KEY NOTES (D VERIFY IN FIELD FOR EXACT PANEL LOCATIONS. © PROVIDE 3/4"PVC. 2#10, 1#10 E.G., 1#10 ISOLATED GROUND FOR MENUBOARD. BURY CONDUIT AT 24" BELOW GRADE. SEE SHEET E-4 FOR ADDITIONAL INFORMATION AS PART OF THIS INSTALLATION. ALL ELECTRICAL ASSEMBLIES THAT ARE COVERED BY A LISTING AGENCY INCLUDING LIGHTED SIGHT SHALL HAVETHEIR LABEL AND STICKER OF INFORMATION REQUIRED BY CEC 2016-600 L4 ENGINEERING UC. #E 15596 12832 VALLEY VIEW STREET. STE.D GARDEN GROVE, CA 92845 TEL (949) 521-3092 Email. lanvnguyen@sbcglobal.net ~ ~ ~ I I "' u ~ /l -!;J m ~~ u§ ~:i "'~ I -~ ;;~ i::-~~ !i ~. ~r: ~I " 0 .0 "' I .::: 0 '-' "' ~ 0 I C I-·.::; C :::, w 0 >-~ 0 j " ! ·c C I 1 ., "' > <( <( 0 "' ~ 0 a, q 0 NI :::, C I ~ 0 0 Q 5 g~ V '~ Ii~ 8 8 E-3 El..ECTRICAL. SITE Pl.AN NOTE: • VERIFY EXACT CIRCUITS & QUANTITIES OF CIRCUITS WITH PANEL SCHEDULES AND MANUFACTURERS INSTALLATION INSTRUCTIONS. • IF IMPLEMENTING NEW EXTERIOR DIGITAL MENUBOARDS AT AN EXISTING RESTAURANT, VERIFY EXISTING CP PANEL HAS AMPACITY AND SUFFICIENT SPARES/SPACE FOR TWO (2) NEW 20A/1 P CIRCUITS. UPGRADE CP PANEL TO 42 CIRCUITS IF NECESSARY. • IF IMPLEMENTING NEW EXTERIOR OIGrTAL MENUBOARDS AT AN EXISTING RESTAURANT, VERIFY EXISTING PULLBOXES ARE SIZED FOR NEW CONDUIT ROUTING. MODIFY PULLBOXES IF NECESSARY. @ (1) 1-1/4"C.2#12, 1#12 GND & 1#12 ISOLATED GROUND TO IG PANEL 'EP /CP' FOR ISOLATED GROUND POWER TO MENUBOARD INSIDE OUTSIDE I MENU f--l BOARD #1 r PRIMARY DT LANE ----------.--1--,-------- ~~p I MENU f--- BOARD #2 1 SECONDARY DT LANE (3\ DRIVE THRU POWER DIAGRAM \__:___) NOT TO SCALE b MANAGER I OFFICE I I I I cb '----(1) 2"C. l<l>:---(1) 2"C. (1) 2"C. FOR CAT.6 CABLESl I MENU I l r tJ BOARD # 1 1'-'v+------Jl.:.u. PULL BOX FOR FOR INSIDE OUTSIDE CAT.6 CABLES CAT.6 CABLES PRIMARY DT LANE '~ (1) 2"C. FOR CAT.6 CABLES (1) 2"C. FOR CAT.6 CABLES7 r MENU 1 1 - BOARD #2 I PULL BOX ALL CAT.6 CABLES ARE PROVIDED BY: OMNITRONIX. JASON ERNST EMAIL: jasanernst@omintronix.com TELE: 630-209-0182 PROVIDE 3 CAT.6 CABLES -MENU BOARD ---------------SECONDARYDT (2\ OT LOW VOLT AGE \__:___) NOT TO SCALE CONDUIT DIAGRAM LANE L4 ENGINEERING UC. #E1 5596 12832 VALLEY VIEW STREET. STE.D GARDEN GROVE, CA 92845 TEL. (949) 521-3092 Email. lanvnguyen@sbcglobal.net ~ ~ ~ ' I -<( u - ~ /l -b m u!,j 4!~ Jj;:::: q; -~ .~ 1:-i~ i! f;r::. ~i ~o. .,, 0 .0 (I) I ,:: 0 u (I) .1 0 i C ·o C w l 0 .,, I~ ·c Q) I ~ (I) 0 ~i 'o ~ 0 Jim .....!'. C 0 0 QE §~ O il ~~ 0 0 ~ E-4 i OETAJL.S