Loading...
HomeMy WebLinkAboutCUP 99-14; CARLSBAD HIGH SCHOOL - SD 295-01; Consistency Determination' ,J I( 11 Q 0 ~ ' II V) ~ ' ii-. :t: ' Cl I ~ ... \ " ~ .. ~ I\. tj ~ st '-' \j JUMP RUNWAY AND PIT (SHOWN \ INSTALL NEW TRACK & FIELD LONG \ SHADED) \ EXISTING CONTOUR LINES ----\ \ AT 1' INTERVALS \ EXISTING JOINT TRENCH--\ 1 FOR TELEPHONE & POWER '\ SERVICE FEEDS \ \ \ \ \ EXISTING GATES TO REMAIN ' \ -,---EXISTING 6'-0" HIGH CHAINLINK \ FENCE TO REMAIN 18' -3" "INTERIOR" PROPERTY LINE EXSITNG ELECTRICAL BOX 159'-6" / EXISTING LAWN AREA I EXISTING CONCRETE---~ / DRAINAGE SWALE TO REMAIN. \ I REPAIR AS REQUIRED \ I I \ ---------------======t:~ --;.-,---·-•·\4--~~-:=_ _, -I I ___ ,---•--\ 12'-8" \ /,-~·--· LEXISTING \ \ • "COMMUNICATION" 1\ ,/'\ BOX -----//' \ ~ 1-· , .. / \\\ \, EXISTING TRACK & FIELD :-\ \ LONG JUMP RUNWAY TO REMAIN \ , (TYPICAL) REMOVE AND RELOCATE ,_,_,_,_,_,_, ,_ I EXPAND EXISTING CINGUL.AR WIRD.ESS TELECOMMUNICATION EQUIPMENT CABINET ENCLOSURE. INSTALL A NEW CONCRETE SLAB. CONCRETE BLOCK WALL AND CHAINLINK FENCE. (SHOWN SHADED). SEE SHEET A-1 FOR ENLARGED EQUIPMENT PLAN EXISTING PALM TREES TO REMAIN EXISTING CONCRETE GRANDSTAND AND STAIRS TO REMAIN SECTOR B AZIMUTH 120' 19'-4" , 13'-o" 2'-4" EXISTING CINGULAR WIRELESS ANTENNAS MOUNTED AT 58' -6" ON A 70' -0" HIGH LIGHT STANDARD TO REMAIN VERIFY VERIFY I ERIFY END OF_// ~ EXISTING CONCRETE • WALK SECTOR C AZIMUTH 240" CENTERLINE OF LIGHT STANDARD EXISTING CURB, GUTTIER AND SIDEWALK TO REMAIN \ \ ."-REMOVE EXISTING CHAINLINK FENCE --~ "·· ••••••• _ EXISTING SDG&E TRANSFORMER AND SBC ) / / f \\ \ SAND PIT (SHOWN DASHED) \ ~ EXISTING CHAINLINK FENCE ,,\ AROUND RUNNING TRACK \\ ~--EXISTING FOOTBALL FIELD AND TRACK REPLACE EXISTING CINGUL.AR WIRD.ESS METER PEDESTAL. WITH NEW 200 AMP TESCO PEDESTAL \ POC ON EXISTING UTILITY POLE #127740 \ \ ENLARGED SITE PLAN SCALE: 1' • 'Ill EXISTING "AIRTOUCH" TELECOMMUNICATIONS EQUIPMENT BUILDING AND ANTENNA TOWER STRUCTURE EXISTING ACCESS GATE TO RUNNING TRACK EXISTING SDG&E AND SBC ---~ UTILITY POLE SITE PLAN . I / I / HIGH \. \ \ \ SCHOOL-----, TO REMAIN ~---REMOVE EXISTING TRACK & FIELD LONG JUMP RUNWAY AND PIT. INSTALL NEW RUNWAY AND PIT (SHOWN SHADED) ~----EXISTING GATE TO REMAIN NOTE: FOR ADDITIONAL SITE DIMENSIONS AT PROPOSED EQUIPMENT ENCLOSURE AND LIGHT STANDARD SEE SHEET A-1 EXPAND EXISTING CINGUL.AR WIRELESS TELECOMMUNICATION EQUIPMENT ~--~ENCLOSURE. SEE ENLARGED SITE PLAN ABOVE. ' EXISTING CINGULAR WIRELESS ANTENNAS ~---1MOUNTED ON A 70'-0" HIGH LIGHT STAN DARO TO REMAIN \\ DIMENSION NOTE: ~ DIMENSIONS SHOWN FROM PROPERTY LINES ARE APPROXIMATE \ / AND ARE SHOWN FOR GENERAL REFERENCES. REFER TO 1 / DIMENSIONS ON ENLARGED SITE PLAN ABOVE FOR POLE AND , / EQUIPMENT LOCATIONS REFERENCED TO EXISTING FEATURES IN \ // THE IMMEDIATE VICINITY OF PROPOSED WORK \ ___ ,.,..,.,,. /\ ' \ \ \ ~ \ \\ \\ -i ~ \~ \.'\\i. ~ '~ ' \~\ ,11 I 'b . \ 'O, \\\\ cuP CONSISTENCY DETERMINATIOro iXBJBft \J¼£..,p~Q01 I DATI: 1/r~/M-IIOCBAELJ. no Plwa.tiu1 Dircctm MCXIMMENDED av-11~ ,J lw~ IIAff: <./, f DI/ CINGULAR WIRELESS TELECOMMUNICATIONS TRANSMITTER FREQUENCIES AND POWER LEVELS: ~\ ~ \ \ ' ~.,:,,, 1121.IIB' '~ '\ 1850-1990 MHz BAND WIDTH 800 WATTS ERP PER SECTOR , ' N er57'3o" E llENCHMARK: TOP OF FIRE HYDRANT ON THE WEST SIDE OF MONROE STREET, EAST OF HIGH SCHOOL CAFETERIA PER CITY OF CARLSBAD FIELD BOOK 2, PAGE 73. ELEVATION 215.02' (MEAN SEA LEVEL N.G.V.D. 1929). l!IOUNDARY NOTE: THE PROJECT BOUNDARY SHOWN ON THIS DRAWING IS APPROXIMATE AND IS SHOWN FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED BY CHRISTENSEN ENGINEERING & SURVEYING. GENERAL SPECIFICATIONS 1. THE LATEST EDITION OF THE AMERICIIN INSTITUTE OF ARCHITECTS DOCUMENT A201 "GENERA!. CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" ARE INCLUDED IN THESE SPEClflCATIONS AS IF COMPLETELY REPRODUCED HEREIN. 2. THIS FACILITY IS AN UNOCCUPIED PCS TELECOMMUNICATIONS SITE AND IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. J. PRIOR TO THE SUBMISSION OF BIDS, THE CON'TRACTORS PARTICIPATING SHALL ~SIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT, WITH THE CONSTRUCTION /IND CONTRACT DOCUMENTS, flELD CONDITIONS AND CONflRM THAT THE PROJECT CAN BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. SHOULD AfN ERRORS, OMISSION, OR DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY CINOUlAR WIRELESS PROJECT MIINAGER AND THE ARCHITECT IN WRITING. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL INCLUDE THE MORE COSTLY OR EXTENSIVE WORK IN THE BIO, UNLESS SPECIFICALLY DIRECTED OTHERWISE. IF A DISCREPANCY EXISTS AND THE PROJECT MANAGER AND ARCHITECT ARE NOT NOTIFIED, THE GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL COSTS INCURRED TO REP.oJR OR CORRECT ALL PROBLEMS THAT RESULT. ~-DRAWINGS SHALL NOT BE SCALED. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE AND DETAIL DRAWINGS HAVE PRECEDENCE QI/ER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAS BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. 5. CONTRACTOR SHALL NOTIFY THE CINGIJlAR WIREl!SS PROJECT MANAGER AND THE ARCHITECT IF ANY DETAILS ARE CONSIDERED IMPRACTICAL, UNSUITABLE. UNSAFE. NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF' WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TO ANY DETAIL. DET.oJLS ARE INTENDED TO SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS, ANO SHALL BE INCLUDED AS PART OF THE WORK. 6. EXISTING ELEVA.T10NS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF' THEY DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE CINGUlAR WIRELESS PROJECT MANAGER AND THE ARCHITECT SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 7. ALL SYMBOLS AND ABBRE"1ATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING. THE CINOUlAR WIRELESS PROJECT MANAGER AND THE ARCHITECT SHALL BE NOTIFIED FOR ClARIFlCATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK. 8. THE CON'TRACTOR SHALL OBT.oJN AND PAY FOR PERMITS, LICENSES AND INSPECTIONS NECESSARY F'OR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN THE COST OF THE WORK TO CINGULAR WIRELESS 9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT ALL WORK. USING HIS BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES /IND SEQUENCES ANO FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 10. WORKMANSHIP THFIOUGHOUT SHALL BE OF THE BEST QUALl!Y OF THE TRADE INVOLVED, AND SHALL MEET OR EXCEED THE F'OLLOWING MINIMUM REFERENCE STANDARDS FOR QUALIIY AND PROFESSIONAL CONSTRUCTION PRACTICE: NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION O'HARE INTERNATIONAL CENTER 10255 w. HIG~NS ROAD, SUITE 80D ROSEMONT, IL 60018 SMACNA SHEET METAL ANO -'JR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION 4201 LAFAYETTE CENTER DRIVE CHANTILLY, VA 20151-1209 IILP INTERNATIONAL INSTITUTE FOR LATH AND PLASTER 820 TRANSFER ROAD ST. PAUL, MN 55114-1405 AMA ADHESM: MANUFACTURERS ASSOCIATION 401 NORTH MICHIGAN AVENUE, SUITE 2<IOO CHICAGO, IL 60611 11. THE CONTRACTOR SHALL VERIFY, COORDINATE, AND PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORTS FOR ALL ITEMS REQUIRING THE SAME. 12. THE CONTRACTOR AND ALL SUBCON'TRACTORS SHALL COMPLY WITH ALL LOCAL CODES, REGULATIONS, AND ORDINANCES AS WELL >S STATE DEPARTMENT OF INDUSTRIAL REGULATIONS AND DMSION OF INDUSTRIAL SAFElY (OSHA) REQUIREMENTS. 13. THE CONTRACTOR SHALL PROTECT THE PROPERTY OWNERS, AND CINGUlAR WIAE.J!SS PROPERTY FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. /\NY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE. LANDSCAPING, CURBS, STAIRS, OR EQUIPMENT, ETC, SHALL BE IMMEOIATELY REP.oJREO OR REPLACED TO THE SATISFACTION OF' CINGUlAR WIRELESS, OR THE PROPERTY OWNER, OR THE OWNER'S REPRESENTATIVE, AT THE EXPENSE OF THE CONTRACTOR. 14. THE CONTAACTOR SHALL BE RESPONSISLE FOR, AND SHALL REPLACE OR REMEDY, ANY F'AUL!Y, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE: YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK BY CINGULAR WIRELESS UNDER THIS CONTRACT. 1~. IT SHALL BE THE RESPONSIBIU!Y OF THE GENERAL CONTRACTOR TO LOCATE'. ALL EXISTING UTILITIES, WHrn-lER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES F'OR REPAIR OR REPu\CEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK. 1 &, THE CONTRACTOR SHALL BE RESPONSIBLE F'OR THE COMPLETE SECURITY OF THE PROJECT SITE WHILE THE JOB IS IN PROGRESS ANO UNTIL THE JOB IS COMPLETED AND ACCEPTED BY CINGUlAR WIRELESS 17. THE CONTRACTOR SHALL PROIIIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED BY THE PROPER!Y OWNER, CINGUlAR WIRELESS, AND THE Cl!Y OR GOVERNING AGENCY. 18. THE LATEST EDITION OF ALL PERMITTED AND APPROVED PLANS PERTAINING TO THIS PROJECT SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. THESE ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 19. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS ON A DAlLY BASIS, AND SHALL EXERCISE STRICT CONTROL OVER JOB CLEANING THROUGHOUT CONSTRUCTION, INCLUDING FINAL CLEAN-UP UPON COMPLETION OF WORK. ALL AREAS ARE TO BE LEFT IN A BROOM CLEAN CONOITION AT THE END OF EACH DAY. 20. THE GENERAL CONTRACTOR MUST PERFORM WORK DURING PROPERTY OWNER'S PREFERRED' HOURS TO AVOID DISRUPTION OF NORMAL ACTM1Y. 21. ALL El<POSED METAL SHALL BE HOT-DIPPED GALVIINIZED. 22. SEAL ALL PENETRATIONS THROUGH flRE-RATED AREAS WITH U,L LISTED OR F'IRE MARSHALL APPROVED MATERIALS IF AND WHERE APPLICABLE TO THIS FACILITY AND PROJECT SITE. 23. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA CONSTRUCTION. 24. ELECTRICAL POWER SYSTEM SHALL BE GROUNDED PER NEC ARTICLES 2M ANO e10. 2~, ALL NEW OPENINGS IN THE EXTERIOR ENVELOPE OF CONDITIONED SPACES SUCH AS AT WALL /IND ROOF PENETRATIONS SHALL BE CAULKED OR SEALED TO LIMIT INFILTRATION Of AIR AND MOISTURE. 25. UPON COMPLETION or CONSTRUCTION, CIIIOUI.AR WIREl!SS PROJECT MANAGER SHALL CONDUCT A WALK-THRU WITH PROPEERTY OWNER OR REPRESENTATIVE or PROPERlY OWNER PROPRIETARY INFORMATION THE INFORMATION CONT.oJNED IN THIS SET OF DESIGN DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CINGUL.AR WIRELESS IS STRICTLY PROHIBITED. ARCHITECTURE PLANNING WILLIAM M. aooTH. ARCHITECT P.OBEP..T ). SUAI\EZ. Ali.CHITECT P.O. DOX --4651. CAkLSBIID, CA. '1''201& (760) 434·8H4 == ========= PREPARED FOR ~ cingular .. WIRELESS 6170 CORNERSTONE CT., SUITE 180 SAN DIEGO, CA 92121 APPROVALS R.F. DATE ZONING DATE CONSTRUCTION DATE SITE ACQUISITION DATE OWNER APPROVAL DATE H PROJECT NAME CARLSBAD HIGH SCHOOL PROJECT NUMBER SD-295-01 3557 MONROE STREET CARLSBAD, CA 92008 SAN DIEGO ========= .. .. 10/01/03 10/08/03 10/31/03 DRAWING DATES PRELIM ZD REVIEW (raw) FINAL ZD REVIEW (ral) SCHOOL DISTRICT REVISIONS (Jab) SHEET TITLE SITE PLAN, ENLARGED SITE PLAN & GENERAL SPECIFICATIONS C LA P q 'I-I</ II PROJECTS\clngular\03071 zd\03071 zAO.DWG .. ========= .. A-0