Loading...
HomeMy WebLinkAboutCUP 99-14; CARLSBAD HIGH SCHOOL - SD 295-01; Site PlanEXISTING "AIRTOUCH" TELECOMMUNICATIONS EQUIPMENT BUILDING AND ANTENNA TOWER STRUCTURE EXISTING ACCESS GATE TO RUNNING TRACK I .X I / I CENTERLINE OF LIGHT STANDARD (TYPICAL) I I I l I I I I I I I I I I / I I I I ATHLETIC FIELDS SITE PLAN SCALE; 1" • 200' ·--cl, I I I I I I _j I I I I I I I I I I \ \ NOTE: FOR ADDITIONAL SITE DIMENSIONS AT PROPOSED EQUIPMENT ENCLOSURE AND LIGHT STANDARD SEE SHEET A-1 \~ \ 11 PROPOSED PACIFIC BELL WIRELESS BTS EQUIPMENT ENCLOSURE. 1 -1_,,-----1SEE SHEET A-1 FOR AN ENLARGED \ / PLAN OF THIS AREA. ,\ \ I \ \ / \ I I ;\ \ I/ \ I / \ I I ~ \/ i A \/ ' \ \ I \ \. ·\ . \\ \ '"' ,. 0 "' \ I I \ \ I \ \ PROPOSED PACIFIC BEU_ WIRELESS ANTENNAS MOUNTED AT 58' -6" ON -------< A 70' -0" HIGH LIGHT STANDARD. \ \ \_ \ \ I \ \ SEE SHEET A-1 FOR AN ENLARGED PLAN OF THIS AREA (REPLACE EXISTING LIGHT STANDARD) I DIMENSION NOTE: DIMENSIONS SHOWN FROM PROPERTY LINES ARE APPROXIMATE AND ARE SHOWN FOR GENERAL REFERENCES. REFER TO DIMENSIONS ON SHEET A-1 FOR POLE AND EQUIPMENT LOCATIONS REFERENCED TO EXISTING FEATURES IN THE IMMEDIATE VICINITY OF PROPOSED WORK _L:::,_ __ _ CARLSBAD HIGH SCHOOL I I I \ I I I ' \ \ \ \ \ \_ PROPERTY LINE (TYPICAL) BENCHMARK: TOP OF FIRE HYDRANT ON THE WEST SIDE OF MONROE STREET, EAST OF HIGH SCHOOL CAFETERIA PER CITY OF CARLSBAD FIELD BOOK 2, PAGE 73. ELEVATION 215.02' (MEAN SEA LEVEL N.G.V.D. 1929). BOUNDARY NOTE: THE PROJECT BOUNDARY SHOWN ON THIS DRAWING IS APPROXIMATE AND IS SHOWN FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED BY CHRISTENSEN ENGINEERING AND SURVEYING APPROVE!) f"l tlS l~ lt·•:·;·.~ ,·11·; •. ,~")VFD Tf)\T.-'\TIVF ~.,ff\P 1S/TE Pi.A'', ~'i_F ~ "( :··, , '.J': '7'6_6_1·_1._or PL/: \~\iT\G ( ,;:·ll•vtf" ,.\ ., :>s!i l ,.,J:~ NO . .1.b.t.1'. ___ _ ~~~1~ ~4,._ ~ ·--)-UOD r:+:_;·:1-,. -1·i1· ,,_ ... ., r·u,: GENERAL SPECIFICATIONS 1. THE LATEST EDITION OF THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A2D1 "GENERAL CONDITIONS OF THE CONTRACT FDR CONSTRUCTION" ARE INCLUDED IN THESE SPECIFICATIONS AS IF COMPLETELY REPRODUCED HEREIN. 2. THIS FACILITY IS AN UNOCCUPIED PCS TELECOMMUNICATIONS SITE AND IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS PARTICIPATING SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS AFFECTING THE PROPOSED PROJECT INCLUDING DEMOLITION, ELECTRICAL, MECHANICAL AND STRUCTURAL INSTALLATIONS, AS WELL AS WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS AND SHALL CONFIRM THAT THE PROJECT CAN BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. SHOULD ANY ERRORS, OMISSION, OR DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT IN WRITING. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL INCLUDE THE MORE COSTLY DR EXTENSIVE WORK IN THE BID, UNLESS SPECIFICALLY DIRECTED OTHERWISE. IF A DISCREPANCY EXISTS AND THE PROJECT MANAGER AND ARCHITECT ARE NOT NOTIFIED, THE GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FDR ALL COSTS INCURRED TO REPAIR OR CORRECT ALL PROBLEMS THAT RESULT. 4. DRAWINGS SHALL NOT BE SCALED THESE DRAWINGS ARE INTENDED TO BE DIAGRAMMATIC ONLY. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAS BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS 5. THE CONTRACTOR SHALL INCLUDE IN HIS OR HER BID ALL MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE THE WORK AS INDICATED DR IMPLIED BY THESE DRAWINGS. 6. CONTRACTOR SHALL NOTIFY THE PACIFIC BELL WIRELESS PROJECT MANAGER, THE PROPERTY OWNER AND THE ARCHITECT IF ANY DETAILS ARE CONSIDERED IMPRACTICAL. UNSUITABLE, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TD ANY DETAIL DETAILS ARE INTENDED TD SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TD SUIT JOB CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK. 7. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT SD THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 8. THE CONTRACTOR SHALL VERIFY ALL TELEPHONE & RADIO EQUIPMENT LAYOUTS, SPECIFICATIONS, PERFORMANCE. INSTALLATION AND FINAL LOCATIONS WITH PACIFIC BEU_ WIRELESS PROJECT MANAGER PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH ERICSSON RADIO SYSTEMS. 9. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK. 10. THE CONTRACTOR SHALL OBTAIN AND PAY FDR PERMITS, LICENSES AND INSPECTIONS NECESSARY FDR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN THE COST OF THE WORK TD PACIFIC BEU_ WIRELESS 11. THE CONTRACTOR SHALL PROVIDE CONTINUOUS SUPERVISION WHILE ANY SUBCONTRACTORS OR WORKMEN ARE ON THE SITE AND SHALL SUPERVISE AND DIRECT ALL WORK, USING HIS BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FDR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT 12 WORKMANSHIP THROUGHOUT SHALL BE OF THE BEST QUALITY OF THE TRADE INVOLVED, AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM REFERENCE STANDARDS FOR QUALITY AND PROFESSIONAL CONSTRUCTION PRACTICE: NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION O'HARE INTERNATIONAL CENTER 1 0255 W. HIGGENS ROAD, SUITE 600 ROSEMONT, IL 60018 SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION ITLP 4201 LAFAYETTE CENTER DRIVE CHATILLY, VA 22021-1209 INTERNATIONAL INSTITUTE FOR LATH AND PLASTER 820 TRANSFER ROAD ST. PAUL, MN 55114-1406 13. INSTALL ALL EQUIPMENT AND MATERIALS PER THE LATEST EDITION OF THE MANUFACTURER'S INSTALLATION SPECIFICATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED, DR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 14, THE CONTRACTOR SHALL VERIFY, COORDINATE, AND PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORTS FOR ALL ITEMS REQUIRING THE SAME. 15. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL GIVE ALL NOTICES AND SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES, REGULATIONS, LAWS AND ORDINANCES AS WELL AS STATE DEPARTMENT OF INDUSTRIAL REGULATIONS AND DIVISION OF INDUSTRIAL SAFETY (OSHA) REQUIREMENTS. 16. THE CONTRACTOR SHALL PROTECT THE PROPERTY OWNERS, AND PACIFIC BELL WIRELESS PROPERTY FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING FINISHES, CONSTRUCTION, STRUCTURE, LANDSCAPING, CURBS, STAIRS, OR EQUIPMENT, ETC, SHALL BE IMMEDIATELY REPAIRED OR REPLACED TD THE SATISFACTION OF PACIFIC BELL WIRELESS. AND THE PROPERTY OWNER, OR THE OWNER'S REPRESENTATIVE, AT THE EXPENSE OF THE CONTRACTOR. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REPLACE OR REMEDY, ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK BY PACIFIC BELL WIRELESS UNDER THIS CONTRACT. 18. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, OR CONTACT AN OUTSIDE AGENCY TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK 19 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE PROJECT SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED AND ACCEPTED BY PACIFIC BEU_ WIRELESS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SE"J' OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RE:;LATE:S TO PACIFIC BELL WIRELESS IS STRICTLY PROHIBITED. ARCHl"EC:lUR( ■■ ■■ PL.Al'l'lll'IG \.JILLll'IM M. BOOTH. 1'11\CH TKT fl,OClOT J SIJAl\O /lf\CHl'lla:C::-1 P. 0 ~ox ~<,;ii C:f!Rl'.'>~fl[). C/1. 9'2011:> (7~0) 4-3-4 8474 .. .. PREPARED FOR PACIFIC ti BELL® Wireless 4420 ROSEWOOD DRIVE BUILDING 2, FOURTH FLOOR PLEASANTON, CALIFORNIA 94588 •• .. APPROVALS OPERATIONS DATE RF. DATE ZONING DATE CONSTRUCTION DATE SITE ACQUISITION DATE ===== :: ===== PROJECT NAME CARLSBAD HIGH SCHOOL PROJECT NUMBER SD-295-01 3557 MONROE STREET CARLSBAD, CA 92008 SAN DIEGO ========= :: ========= DRAWING DATES 6/9/99 6/16/99 6/22/99 6/28/99 11/4/99 11/17/99 PRELIM ZD REVIEW ZD SUBMITTAL ZD REVISIONS FINAL ZONING PRELIM CO REVIEW CD SUBMITTAL ========= :: ========= SHEET TITLE SITE PLAN GENERAL SPECIFICATIONS •. ======== ■■ PROJECTS\ PBW\ 9 9 033cd\ 99 033cAO, OWG ===== :: ===== A-0