Loading...
HomeMy WebLinkAboutMS 15-13; QUARRY CREEK PA R-1 & R-2; SEWER DESIGN REPORT; 2016-03-07Sewer Design Report Project No. SDP 15-22 /SDP 15-17/MS 15-13 Private Access Road/ Driveway A R-1 Sewer 484-5H QUARRY CREEK PLANNING AREAS R-1 & R-2 City of Carlsbad, Ca County of San Diego PREPARED FOR: CORNERSTONE COMMUNITIES 4365 EXECUTIVE DRIVE, SUITE 600 SAN DIEGO, CA 92121 RECEIyI) MAR 09'2016 PREPARED BY: LAND DEVELOPMENT ENGINEERING rmB&C3~ PLANNING ENGINEERING SURVEYING 3990 RUFF1N ROAD, SUITE 120 SAN DIEGO, CA 92123 (858)560-1141 SB&O JOB NO. R-1 71820.60/R-2 71920.60 ((~~No.47107 II - Exp. 12-31-17 :\ eivijL TABLE OF CONTENTS Vicinity Map Scopeof Report ............................................................................................................................... 1 Quarry Creek Development............................................................................................................1 PlanningArea R-1 & R-2 ...............................................................................................................1 Methodology...................................................................................................................................2 SewerHydraulics............................................................................................................................2 Results.............................................................................................................................................3 Conclusion.......................................................................................................................................3 EXHIBITS SiteSewer Map..............................................................................................................Map Pocket APPENDIX City/CMWD Design Standards Volume I Chapter 6 (Gravity Sewer) Excerpts D:\71822 QC PA IRepoits\Sewe?UO 160307 QCRIRI Sewer Repoitdocx EL 0"INO COUNTRY CLUB AuRA I COSTA COLLEGE Iqz Iri . WAY DA 78\ HA YA64R I DR M4RRON SITE LAKE RD. VICINITY MAP NOT TO SCALE THOMAS BROTHERS P6'. 1107, GRID A-2 2006 EDI170N D\7 1822 QC PA I\Reports\Sewer\20 150307 QCR1R2 Sewer Report docx Scope of Report This report is limited to sewage flow estimates and hydraulic calculations of the proposed public sewer main and the private sewer mains connections from the R-1 and R-2 sites. The public 8" sewer will be located in a sewer easement at the southerly project limits, adjacent to the water quality / detention basins. Since these Planning Areas are part of the Master Quarry Creek Development, no calculations were prepared to analyze the downstream flow conditions or potential impacts. Quarry Creek Development The Quarry Creek development is located in the City of Carlsbad (City), but is bordered to the east by the City of Oceanside. The development is situated west of College Boulevard, east of Interstate 5 and south of Haymar Drive. The development is divided north and south by the Buena Vista Creek which runs east to west across the middle of the site. The Quarry Creek development is 155.36 acres in gross project size with the addition of some off-site grading and improvements. The first phase of Quarry Creek created large sheet graded pads, and infrastructure for the including public roads, backbone public utilities, and the water quality and detention facilities to support the entire development. Planning Area R-1 & R-2 The R-2 area will be a multi-family residential development. A total of 278 units will be constructed, consisting of various attached product types including 2 and 3 story buildings. A recreational area with restrooms will be modeled as 1 EDU, for a total of 279 EDUs. A private 8" sewer main will collect onsite flows and discharge into a proposed public 8" sewer line at 2 locations. Several of the buildings located adjacent to the public main may include a direct connection to the proposed public 8" line. A copy of the Sewer Site Map is provided in the Map Pocket at the back of the report. The R-1 area is a similar multi-family residential development. The R-1 area (64 EDU) is located upstream of the project and will discharge to the 8" public sewer located at the Street "A" cul-de-sac. A restroom building (modeled as 1 EDU) is expected to be constructed at the future Cultural Center to be located across Street "A" from the R-1 site. A total of 65 EDU will discharged to the upstream end of the proposed 8" sewer. See Proposed Sewer Exhibit located in the Map Pocket. D:V7 1822 QC PA flRepor1sSeweti20 160307 QCRIR2 Scwcr Rcpon.docx Methodology Public sewer lines are to be designed in accordance with City/ CMWD Engineering Design Standards Volume I, Chapter 6, as follows; Hydraulic calculations shall be based upon a normal "n" value of 0.011. Minimum 8" diameter main (6" mains may be used with a maximum of 10 units). Sewer mains shall be designed for a minimum velocity of 2 feet per second (peak dry weather). Depth of flow shall not exceed Mull for 12" diameter pipe and smaller. Flowrate generation using 1 Equivalent Dwelling Unit (EDU) = 220 gallons per day. Peaking factors for small basins (<100,000 gpd) are set at a constant 2.5. Small sewer basins are typically limited in achieving a target cleansing velocity of 2 fps. Due to the limited sewer demand from the future Cultural Center, and the relatively mild street slope, the minimum 6" dimeter main will be used for the uppermost public reach, located in Street "A". Sewer Hydraulics The following table summarizes the peak flows for the R-1 & R-2 projects; MH Tributary Area EDU Cumm. EDU Daily Flow (gpd) Average Flow (mgd) Peak Flow (mgd) Dia (in) Slope (%) Depth (ft) Velocity (fps) R-1 & Future Cultural Center______ 10-9 Restroom 1 1 220 0.0002 0.0006 [_6 1.03 0.013 0.60 9 R-1 Private 64 64 14,080 0.014 0.035 8 1.03 0.088 2.00 9-8 Street A 65 14,300 /Public 0.014 0.036 8 1.03 0.089 2.01 R-2 Sewer 8-5 Public Street A 65 14,300_f0.014] 0.03681.03 0.089_J2.01 5 R-2 (East) 51 11,220 0.011 0.028 8 1.25 0.075 2.00 5-4 Public Sewer 116 25,520 0.026 0.064 8 1.03 0.18 2.35 R-2 (West) 228 50,160 Private 0.050 0.126 8 1.03 0.166 2.87 4-1 Public Sewer I 344 75,680 0.076 0.293 8 1.03 0.205 3.22 Notes: n value =0.011 Results A review of the hydraulic results indicates flow depths less than 1/3 full. Peak velocities in the public mains, except for the reach above R- 1, will be at or greater than the 2 fps threshold. The private connecting sewer mains will achieve the 2 fps cleansing velocity. Onsite private mains may be sized at 6" to improve hydraulics. The upper reaches of the private main will not achieve the desired 2 fps, due to the limited population (future Cultural Center). Conclusion The proposed private 8" sewer mains will achieve the target 2 fps cleansing velocity under peak flow conditions, with depth at or below 1/3 full. The 6" public main upstream of R- 11, located in Street "A" will not achieve the 2 fps threshold, due to the limited future sewage demand. The minimum 1% design slope will be used for the 6" main. The proposed private main connection form R-1 and R-2 will achieve the 2 fps cleansing velocity using an 8" main at or slightly steeper than 1% slope. Onsite private mains may be sized at 6" to improve hydraulics. The upper reaches of the private 6" mains will not achieve the desired 2 fps, due to the limited population. APPENDIX City/CMWD Design Standards Volume I Chapter 6 (Gravity Sewer) Excerpts CHAPTER 6 - DESIGN CRITERIA FOR GRAVITY SEWER LINES AND APPURTENANCES Engineer will submit a rough layout of system for review and approval by the City Engineer prior to preparation of improvement plans. 1. SEWER MAIN DEPTH AND SIZE Sewer main depth and size shall be as shown below unless approved by the City Engineer. Minimum depth, finish grade to top of pipe 6 feet Maximum depth, finish grade to top of pipe 15 feet Design calculations shall be submitted to verify size and bedding design. (Manning "N" PVC = 0.011 is norm). Minimum size of mainline shall be 8". 6" main line may be allowed on cul-de-sac streets with a maximum of 10 units. All sewer laterals and main line invert elevations shall be shown in profile on the improvement plans and shall include stations, slope, and distance. All sewer mains over 15" in diameter shall require special design and City Engineer approval. 2. SEWER LATERAL DEPTH AND SIZE 4" minimum diameter for single-family residence. 6" minimum diameter for all other use. Desirable depth at property line is 5 feet (top of pipe to finish grade @ top of curb). 3. PIPELINE MATERIAL TYPES Gravity sewer pipe and fittings shall have PVC conforming to ASTM D3034 for diameters 4" - 15" and ASTM F 679 for 18" - 24", with integral-bell gasketed joints (gasket and spigot end joint design). Pipe shall be made of PVC plastic having a cell classification of 12454-B or 12364-B as defined in ASTM D 1784 and shall have SDR of 35 and a minimum stiffness of 46 psi according to ASTM D 2412. All fittings and accessories shall be as manufactured and finished by the pipe supplier or approved equal and have bell and spigot configurations compatible with that of the pipe. Volume 1 - Chapter 6 Rev. 6/30/08 Page 1 of 8 PVC pipe joints shall be elastomeric gasket joints type conforming to Standard Specifications for Public Works (Greenbook) most recent edition. Rubber gaskets shall be factory installed and conform to ASTM F 477. Pipe joints shall have been tested and meet watertight performance requirements of ASTM D 3212, "Joints for Pipe Using Flexible Elastomeric Seals." PVC C-900 shall be used for gravity sewer pipelines with depths equal or greater than 15 feet. Engineering calculations shall be provided to verify that the pipe material will accommodate the design depth. Use of other pipe and fitting materials and types may be required by the City Engineer to meet specific conditions during design or construction. Service connections to the sewer main shall be watertight and not protrude into the sewer pipe. All materials used to make the service connections shall be compatible with each other and with the pipe material to be joined and shall be corrosion proof. Couplings used for repair, or transition to dissimilar pipe materials shall be approved by the City Engineer and provide corrosion proof watertight seal. 4. DESIGN PARAMETERS FOR GRAVITY SEWER MAIN SLOPE, FLOW AND DEMAND Gravity sewer pipelines shall be designed for a minimum velocity of 2 feet/second. Velocity, unless otherwise stated, shall be calculated from peak dry weather flow. Pipeline slopes shall satisfy the minimum velocity requirement aforementioned. Maximum velocities greater than 10 ft/second should be avoided. Slopes for Specific Pipe Sizes 8 through 12-inch diameter: 8" minimum 0.40% desirable 0.50% 10" minimum 0.28% desirable 0.40% 12" minimum 0.21% desirable 0.30% Slopes for larger than 12-inch diameter pipe shall be designed to meet flow and velocity criteria and require specific approval of the City Engineer. Pipelines with horizontal curvature will require increase slope to achieve minimum required velocities. Gravity pipelines with diameters of 12" and less shall be designed to flow at depths of 0.51D during peak hour dry weather flow. Gravity pipelines with diameters greater than 12" shall be designed to flow at depths of 0.75D during peak hour dry weather flow. Peak hour sewer flow rates do not include infiltration or inflow (Ill). Infiltration is defined as the addition of groundwater into the sewer collection system and inflow is the addition of storm water into the sewer collection system. Because sewer collection system Ill is dependent on a number of factors including season, age of system, type of pipe material and joints, root intrusion, and presence of storm water system, the Ill flow rates will vary from system to system. The design of sewer pipelines connecting to sewer systems known to have I/I, or are susceptible to I/I, shall utilize peak wet weather flow estimates from the City of Carlsbad Sewer Master Plan or perform wet weather flow monitoring as directed by the City Engineer. Gravity pipelines designed to convey wet weather flow shall not exceed 0.90D for peak hour wet weather flow. Volume 1 - Chapter 6 Rev. 6/30/08 Page 2 of 8 E. Flowrate Generation 1) An Equivalent Dwelling Unit (EDU) = 220 gal/day, Average Daily Flow (ADF) 2) For ADF less than 100,000 gal/day, a peaking factor (PF) of 2.5 multiplied times the ADF shall be used to determine Peak Daily Flows (PDF). PDF = ADF x2.5 Residential: Single Family Residence = 1 EDU Commercial Property: I EDU/1 ,800 ft2 (building space) To convert raw land to square feet of building space, assume 30% coverage. This could vary significantly dependent development constraints. To convert improved pads to square feet of building space, assume 40% of coverage. 3) Industrial Property: I EDU/5,000 ft2 (warehouse space) I EDU/1 ,800 ft2 (office space) To convert raw land to square feet of building space, assume 30% coverage. This could vary significantly dependent issues such as environmental restrictions. To convert improved pads to square feet of building space, assume 40% of coverage. Assume 60% of building space is warehouse, and 40% is office space. 5. HORIZONTAL AND VERTICAL LAYOUT Streets: See City of Carlsbad Standard Drawing No. GS-6 for location. Alley: Main to centerline shall be a minimum of three feet (3') offset. Private Street: Shall require special design and conditions. Easement shall be 20 feet minimum. Horizontal Curve: SDR 35, PVC pipe may be curved horizontally through longitudinal bending with the following limitation: :RieDiametei i..tMinFmunvRadiUs óf cuatit'e -; 6-inch 150 feet 8-inch 200 feet 10-inch 250 feet 12-inch 300 feet 15-inch 375 feet City Engineer shall approve curvatures for larger diameter pipe. Volume I - Chapter 6 Rev. 6/30/08 Page 3 of 8 Vertical Curve: Vertical curves shall be permitted only when specifically approved by the City Engineer. A detailed design drawing shall be required for review and approval. Utility Clearances: Show all underground utilities in both plan and profile. Provide minimum separation per the State Department of Health Services "GUIDANCE MEMO NO. 2003-02: GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES". Manholes: Shall be located at areas described as follows: Maximum spacing of manholes shall be three hundred fifty feet (350') for mains twelve inches (12") and smaller and five hundred feet (500') for mains over twelve inches (12") unless otherwise approved by the City Engineer. Install manholes at all changes of slope that exceeds 2% and show inlet and outlet inverts on all manholes. Install manholes at all changes in horizontal direction. Install manholes at all intersections of mains. Install manholes at changes of pipe sizes. Install manholes at the end of all sewer mains. All standard manholes shall be a minimum of five feet (6) in diameter with no steps. Man holes shall be sequentially numbered on the plans with manhole numbers beginning at the lowest invert. Three-foot stubs shall be provided for future tie-ins and main extensions. Manholes shall be PVC lined per Std. Dwg. S-IA when: depth is 15-feet or greater; slope of sewer pipe coming into the manhole is greater than 7%; all force main discharge manholes; the immediate upstream and downstream manholes of inverted siphons; drop manholes; on sewer lines 15-inch and greater; when required by the City Engineer. Where there is a slope change from steep to flat of 5% or greater, the manhole at the grade change and the next manhole upstream shall be PVC lined. Install manholes for all lateral connection in pipelines 15-inch diameter and larger. When intercepting flows from smaller pipelines in manholes, set invert of a smaller main at % of the depth of the larger main. Locking manhole lids may be required in unpaved areas as directed by the City Engineer. The top cone shall be 6" below finished subgrade. Circular steel covers shall be placed on the manholes during subgrade preparation and base rock grade work, in order to keep the sewer system clean. Additionally, roadwork above live sewer manholes shall require plywood type sheeting be placed inside the manhole and above the channel to keep any debris from entering the sewer line. In unpaved areas, sewer manhole frames and covers shall be set 6"above finished grade with concrete ring and marker post marked "sewer" per Standard Drawing S-9. Volume I - Chapter 6 Rev. 6/30/08 Page 4 of 8 H. Cleanouts: Extend beyond permanent pavement when street is a temporary dead end. See Standard Drawing No. S-6 for type of cap and box. 1. Laterals: Laterals shall be constructed per Std. Dwg. No. S-7. Minimum horizontal distance from water service, fire hydrants, light standards, electrical transformers, etc., is 5 feet. Desirable horizontal distance is 10 feet. Install at right angle or radial to the main. Laterals shall jnot be located in driveways. No connections shall be permitted on laterals other than provided in Standard Drawing No. S-7. Location of property cleanout: See Standard Drawing No. S-7. If the lowest plumbing fixture on a property is lower than 2-feet above the nearest upstream manhole cover, then the owner must provide a Backwater Valve to prevent a sewage backup onto the property. The valve must be installed in a valve box for easy access and be visible from the public right-of-way. The property owner shall be responsible for the installation and maintenance of the sewer Backwater Valve. The Backwater Valve shall be shown on the precise grading and improvement plans. The Contractor shall install sewer laterals using wye fittings sized and located as shown on the Approved Plans. Laterals shall be bedded, backfilled and compacted in the same manner as the sewer main they are connected to. J. Steep Slope Protection: 1) Sewer pipelines on 20 percent slopes or greater shall be anchored securely with a cut-off wall per RSD SP-05 or SP-07, spaced as follows: Not over 36 feet center to center on grades 20 percent and up to 35 percent; Not over 24 feet center to center on grades 35 percent and up to 50 percent; and C. Not over 16 feet center to center on grades 50 percent and over. K. All sewer mains, not located within the public right-of-way shall be provided with a minimum 20-foot wide sewer easement. In some special cases, a wider easement may be required; the City Engineer shall determine size. All easements shall be easily accessible to City maintenance equipment with all weather roadways. Volume I - Chapter 6 Rev. 6/30/08 Page 5 of 8 CONNECTIONS TO EXISTING MANHOLES New connections to existing manholes where stubs have not been provided shall be made by core drilling through the walls and base as directed by the City Engineer or their representative. If intercepting flows from smaller pipelines in manholes, set invert of a smaller main at 3/4 of the depth of the larger main. Special care shall be used to facilitate the flow when forming the tributary channel into the existing channel. MISCELLANEOUS REQUIREMENTS The City of Carlsbad will only maintain sewer mains located in dedicated City right-of-ways and easements which have all weather vehicular access. New sewer lines and appurtenances shall remain plugged and/or disconnected until the City authorizes its use. Maintenance of sewer laterals from the main to the building shall be the responsibility of the property owner. Sewer laterals constructed from the property line to the building shall be per the Uniform Building Code. The vertical cleanout shall be stubbed and capped 3 feet above rough grade during grading and/or construction of project. All sewer lateral taps on existing sewer lines shall be by "shewer" or approved equal. All work will be inspected by a City Representative. A three-inch (3") high "5" shall be stamped on the curb face at all sewer lateral locations. GENERAL GUIDELINES FOR SEWER FORCE MAINS The developers engineer shall submit a preliminary design report showing the alignment; pipe size, pressure conditions, pipe materials, a rough layout plan including surge protection design and flow analysis for review and approval by the City Engineer prior to the preparation of improvement plans. Minimum cover of sewer force mains shall be 48 inches (48") from top of pipe to ultimate finished grade. Top of pipe profile shall be shown on the improvement plans. Show all other underground utilities in both plan and profile. Provide minimum clearances per the State of California Department of Public Health (CDPH) "GUIDANCE MEMO NO. 2003-02: GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES". Sewer force mains shall be High Density Polyethylene (HDPE) manufactured in accordance with ASTM F714, or ductile iron pipe with polyethylene liner, and exterior corrosion control as approved by the City Engineer. Where possible, force mains shall be designed with a continuous uphill slope without high points so that air-release valves are not required on the force mains. If this is not possible, provide air-release valves manufactured by Vent-O-Mat. Dual force mains may be required at the discretion of the City Engineer where maintenance will be required on a regular basis or due to environmental constraints. At the discretion of the City Engineer, Force mains longer than 1-mile or with excessive detention times may require the use of chemical addition to prevent odors at the discharge location of the force main. Volume I - Chapter 6 Rev. 6/30/08 Page 6 of 8 - __..J..._. -.. .- .-... . . .-.. .. .. ..-. . ..- .. . .. - - !ZILf;1;1 1i'IfiJi½ T//j Wi J;itwi7iYi V'i 9 LEGEND DESCRIPTION PROPERlY LINE/PROJECT BOUNDARY RIG/IT-OP-WAY LINE CURB AND GUTTER SEWER MAIN SEWER 401. £X/517/VQ CONTOUR DIRECT/ON OF DRAINAGE SEWER BASIN R-1 64 EDU R-2 279 EDU CULTURAL / EDU CENTER TOTAL 344 EDU 7 'N -- PRELIMINARY II CR14 PH/C SCALE wwff_ . . 60 0 60 120 180 FOR REVIEW ONLY Ell Exp. 12 31-17 3990 Ruffin Road, Suite 120 IN 658-5BO-1 141 85B-E56C)-Bl 57 Fax ii flat 7 ' ALLEN L. BUTCHER DATE LU 713-4 2-4-16 71922EX02-PROPOSED SEWER.DWC 71920.20