Loading...
HomeMy WebLinkAboutCUP 00-29; TECHBILT WAREHOUSE; Site PlanEXISTING LANDSCAPE PLANTER EXISTING PARKING STRIPES (TYPICAL) EXISTING CONCRETE CURB (TYPICAL) PROPOSED PACIF'IC BELL WIRELESS ANTENNAS FACADE MOUNTED TO EXISTING BUILDING WALL WITH LNA UNITS MOUNTED TO INSIDE FACE OF PARAPET. ANTENNAS, ANTENNA MOUNTS AND ALL EXPOSED CABLE SHALL BE PAINTED TO MATCH EXISTING ADJACENT SURFACES. SEE EXTERIOR ELEVATIONS SHEET A-2 AND ROOF PLAN SHEET A-1 "' z ~----------=:_------=: SECTOR C AZIMUTH 250' --~----------=:-~ -- PROPOSED PACIF'IC BELL WIRELESS ANTENNAS FACADE MOUNTED TO EXISTING BUILDING WALL WITH LNA UNITS MOUNTED ON INSIDE FACE OF PARAPET. ANTENNAS, ANTENNA MOUNTS AND ALL EXPOSED CABLE SHALL BE PAINTED TO MATCH EXISTING ADJACENT SURFACES. SEE EXTERIOR ELEVATIONS SHEET A-2 AND ROOF PLAN SHEET A-1 -EXISTING CONCRETE CURB (TYPICAL) EXISTING DRIVEWAY BUILDING ENTRANCE --.._ EXISTING ASPHALT----, ~-. •• ..._____;RIVEWAY / -------...-----,--------I OUTLINE OF EXISTING TILT-UP CONCRETE BUILDING PROPOSED STEP-DOWN TRANSFORMER FOR PACIF'IC B'ELL WIRELESS IN ELECTRICAL ROOM Ba~ I \\ PROPOSED SDG&E METER BASE FOR PACIFIC ----, BELL WIRELESS IN ELECTRICAL ROOM BELOW \ I EXISTING PACIFIC BELL MPOE ON TELEPHONE------\ \\ 1 \\ BACKBOARD ON BACKSIDE OF WALL BEHIND ELECTRICAL SWITCHGEAR (TELEPHONE SERVICE \\ \ I ) ' I CONNECTION \ \ \ \'\\ EXISTING LOADING DOCK --\ I ~cr-l~..--------,,1 EXISTING MAIN SWITCHGEAR IN ELECTRICAL ROOM BELOW (POWER SERVICE CONNECTION) I • 0 I R I \/ X \ \ SECTOR B ) AZIMUTH 120' \ ./ ITT \ '--EXISTING PLANTER I \ I I ) APPROVED i,.g.01 . -··· .. ··•----- / EXISTING CURB & GUTTER / (TYPICAL) PROPOSED PACIFIC BELL WIRELESS ANTENNAS FACADE MOUNTED TO EXISTING BUILDING WALL WITH LNA UNITS MOUNTED TO INSIDE FACE OF PARAPET. ANTENNAS, ANTENNA MOUNTS AND ALL EXPOSED CABLE SHALL BE PAINTED TO MATCH EXISTING ADJACENT SURFACES. SEE EXTERIOR ELEVATIONS SHEET A-2 AND ROOF PLAN SHEET A-1 EXISTING CONCRETE TILT-UP --1 A LANDSCAPE A I I 111 I I ~ 11 I I I I I I ~-----'-+-------L-~// TRASH ENCLOSURE WITH CORRUGATED STEEL GATES I I PROPERTY LINE _j I :::~~:) ASPHALT PAVING _JI (TYPICAL) SITE PLAN SCALE: 1" • 30'· O" I N 49' 35' 19" W 464.02' PROPOSED PACIFIC BELL WIRELESS BTS EQUIPMENT CABINETS ON A CONCRETE PAD ON GRADE INSIDE A 6' -0" HIGH POURED-IN-PLACE,-_~ CONCRETE SCREEN WALL WITH A CORRUGATED STEEL GATE (SHOWN SHADED). SEE SHEET A-1 FOR AN ENLARGED PLAN OF THIS AREA CUP NOTES: 1 . THE PANEL ANTENNAS SHALL BE PAINTED TO MATCH THE BUILDING FACADE COLOR AND THE EQUIPMENT ENCLOSURE SHALL BE CONSTRUCTED TO MATCH THE EXTERIOR BUILDING WALLS. 2. ANY TREE WHICH IS REMOVED SHALL BE TRANSPLANTED OR REPLACE IN-KIND. ANY DAMAGED PLANT MATERIALS OR IRRIGATION SYSTEMS SHALL BE REPAIRED OR REPLACED. 136'-0" I L DIMENSION NOTE: DIMENSIONS SHOWN FROM PROPERTY LINES ARE APPROXIMATE AND ARE SHOWN FOR GENERAL REFERENCE. REFER TO DIMENSIONS ON SHEET A-1 FOR EQUIPMENT LOCATION REFERENCED TO EXISTING FEATURES IN THE IMMEDIATE VICINITY OF PROPOSED WORK BENCHMARK: SAN DIEGO COUNTY SURVEY CONTROL. MONUMENT "R1 800 335+00 POT". ELEVATION 313.79 MEAN SEA LEVEL (N.G.V.D. 1929) BOUNDARY NOTE: THIS SITE PLAN WAS DEVELOPED FROM THE RECORD PLAT PROVIDED WITH THE TITLE REPORT AND WAS NOT SURVEYED IN ITS ENTIRETY. FOR DETAILED DATA IN THE VICINITY OF THE PROPOSED PROJECT, SEE SHEETS A-1 AND C-1 ELSEWHERE IN THESE PLANS GENERAL SPECIFICATIONS 1. THE LATEST EDITION OF THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" ARE INCLUDED IN THESE SPECIFICATIONS AS IF COMPLETELY REPRODUCED HEREIN. 2. THIS FACILITY IS AN UNOCCUPIED PCS TELECOMMUNICATIONS SITE AND IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS PARTICIPATING SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITIH ALL FIELD CONDITIONS AFFECTING THE PROPOSED PROJECT INCLUDING DEMOLITION, ELECTRICAL, MECHANICAL AND STRUCTURAL INSTALLATIONS, AS WELL AS WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS AND SHALL CONFIRM THAT THE PROJECT CAN BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. SHOULD ANY ERRORS, OMISSION, OR DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY PACIFIC sru WIRELESS PROJECT MANAGER AND THE ARCHITECT IN WRITING. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL INCLUDE THE MORE COSTLY OR EXTENSIVE WORK IN THE BID, UNLESS SPECIFICALLY DIRECTED OTHERWISE. IF A DISCREPANCY EXISTS AND THE PROJECT MANAGER AND ARCHITECT ARE NOT NOTIFIED, THE GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL COSTS INCURRED TO REPAIR OR CORRECT ALL PROBLEMS THAT RESULT. 4. DRAWINGS SHALL NOT BE SCALED. THESE DRAWINGS ARE INTENDED TO BE DIAGRAMMATIC ONLY. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAS BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. 5. THE CONTRACTOR SHALL INCLUDE IN HIS OR HER BID ALL MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE THE WORK AS INDICATED OR IMPLIED BY THESE DRAWINGS. 6. CONTRACTOR SHALL NOTIFY THE PACIFIC BELL WIRELESS PROJECT MANAGER, THE PROPERTY OWNER AND THE ARCHITECT IF ANY DETAILS ARE CONSIDERED IMPRACTICAL, UNSUITABLE, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TO ANY DETAIL. DETAILS ARE INTENDED TO SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK. 7. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE PACIF'IC BELL WIRELESS PROJECT MANAGER AND TIHE ARCHITECT SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 8. THE CONTRACTOR SHALL VERIFY ALL TELEPHONE & RADIO EQUIPMENT LAYOUTS, SPECIFICATIONS, PERFORMANCE, INSTALLATION AND FINAL LOCATIONS WITH PACIFIC BEl.L WIRELESS PROJECT MANAGER PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH ERICSSON RADIO SYSTEMS. 9. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK. 10. THE CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS, LICENSES AND INSPECTIONS NECESSARY FOR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN THE COST OF THE WORK TO PACIFIC BELL WIRELESS 11. THE CONTRACTOR SHALL PROVIDE CONTINUOUS SUPERVISION WHILE ANY SUBCONTRACTORS OR WORKMEN ARE ON THE SITE AND SHALL SUPERVISE AND DIRECT ALL WORK, USING HIS BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 12. WORKMANSHIP THROUGHOUT SHALL BE OF THE BEST QUALITY OF THE TRADE INVOLVED, AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM REFERENCE STANDARDS FOR QUALITY AND PROFESSIONAL CONSTRUCTION PRACTICE: NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION O'HARE INTERNATIONAL CENTER 10255 W. HIGGENS ROAD, SUITE 600 ROSEMONT, IL 60018 SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION 4201 LAFAYETTE CENTER DRIVE CHATILLY, VA 22021-1209 ITLP INTERNATIONAL INSTITUTE FOR LATH AND PLASTER 820 TRANSFER ROAD ST. PAUL, MN 55114-1406 13. INSTALL ALL EQUIPMENT AND MATERIALS PER THE LATEST EDITION OF THE MANUFACTURER'S INSTALLATION SPECIFICATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 14. THE CONTRACTOR SHALL VERIFY, COORDINATE, AND PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORTS FOR ALL ITEMS REQUIRING THE SAME. 15. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL GIVE ALL NOTICES AND SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES, REGULATIONS, LAWS AND ORDINANCES AS WELL AS STATE DEPARTMENT OF INDUSTRIAL REGULATIONS AND DIVISION OF INDUSTRIAL SAFETY (OSHA) REQUIREMENTS. 16. THE CONTRACTOR SHALL PROTECT THE PROPERTY OWNERS, AND PACIFIC BELL WIRELESS PROPERTY FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING FINISHES, CONSTRUCTION, STRUCTURE, LANDSCAPING, CURBS, STAIRS, OR EQUIPMENT, ETC. SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF PACIF'IC BELL WIRELESS, AND THE PROPERTY OWNER, OR THE OWNER'S REPRESENTATIVE, AT THE EXPENSE OF THE CONTRACTOR. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REPLACE OR REMEDY, ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK BY PACIFIC BEl.L WIRELESS UNDER THIS CONTRACT. 18. IT SHALL BE TIHE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, OR CONTACT AN OUTSIDE AGENCY TO LOCATE ALL EXISTING UTILITIES. WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTIHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK. 19. TIHE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE PROJECT SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED AND ACCEPTED BY PACIF'IC BELL WIRELESS PROPRIETARY INFORMATION THE INFORMATION 001'/TAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO PACIFIC BEIL WIRELESS IS STRICTLY PROHIBITED. fRCHITECTUr,E .. .. \,,J!lllflM M ]()()"II ~R.Cllll"F\"" fli)OFr,-_I SL~~JZ ,HCH1r,c-:T PO DO/\ ~651 C/11\LS~fl~• C/'.I ;1 ·20'16 (:tO) '1i,t. M,11~ ========= .. .. PREPARED FOR PACIFIC El BELL@ Wireless 4420 ROSEWOOD DRIVE BUILDING 2, FOURTH FLOOR PLEASANTON, CALIFORNIA 94588 ======= II APPROVALS R.F. DATE ZONING DATE CONSTRUCTION DATE SITE ACQUISITION DATE OWNER APPROVAL DATE PROJECT NAME CARLSBAD OAKS PROJECT NUMBER SD-377-04 2875 EAST LOKER AVENUE, SUITE C CARLSBAD, CA 92008 SAN DIEGO H DRAWING DATES 4-/20/00 4/25/00 7/5/00 8/17 /00 10/5/00 t 1/2/00 11/16/00 1/8/01 1/18/01 PRELIM ZD REVIEW ZD REVISIONS ZD SUBMITTAL PRE LIM CD REVIEW CD REVISIONS CD REVISIONS PLANCHECK SUBMITTAL PERMIT SET CUP NOTES ========II======== SHEET TITLE SITE PLAN & GENERAL SPECIFICATIONS .. ======== .. PROJECTS\PBW\00073zd\00073zAO.DWG ======== == A-0