HomeMy WebLinkAbout6128 INNOVATION WY; ; AS130217; Permit7/28/22, 3:01 PM AS 130217 Permit Data City of Carlsbad Sprinkler Permit Job Address: 6128 INNOVATION WY Permit Type: SPRINK Parcel No: 2132621301 Lot#: 0 Reference No.: Permit No: AS130217 Status: ISSUED Applied 12/10/2013 Approved: 12/13/2013 Issued: 12/13/2013 PC #: Inspector: Project Title: LABRUM WEALTH Tl Tl INSTALL NEW TENANT PIPING AND (29) SPRINKLERS. 1627 SF Applicant: Owner: INDUSTRIAL FIRE SPRINKLER CO INC 3845 IMPERIAL AV SAN DIEGO CA 619-266-6030 619-266-6035 Fees($) Add'I Fees ($) 268 0 about:blank LABRUM CAPITAL ADVISORS L L C 5650 EL CAMINO REAL #230 CARLSBAD CA Total($) Balance($) 268 0 1 /1 ., QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES FIRE SPRINKLER CORPORATION UPRIGHT• PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL ·-<· DESCRIPTION AND OPERATION CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design require- ments. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. TECHNICAL DATA • See reverse side for Approvals and Specifications. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL • Temperature Ratings -135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141 °C) • Water Working Pressure Rating -175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame -bronze • Deflector -brass • Screw -brass • Bulb seat -copper • Spring -nickel alloy • Seal -teflon • Bulb -glass with alcohol based solution, 3mm size QUICK RESPONSE HORIZONTAL SIDEWALL • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES ORDINARY 135°F/155°F 57°C/68°c INTERMEDIATE 175°F/200°F 79°C/93°C HIGH 286°F 141°c \ 4077 AIRPARKDRIVE, STANDISH, MICHIGAN 48658 DECEMBER 2006 A-20 BULB COLOR ORANGE/RED YELLOW/GREEN BLUE N.F.P.A. MAXIMUM CEILING TEMPERATURE 100°F 38°C 150°F 66°C .225°F 107°C 989-846-4583 • FAX 989-846-9231 BULLETIN GL5615, REV. #6 AS130217 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONA L (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH 1 FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 _ cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1 HORIZONTAL SIDEWALL IS 2 9/16". STYLE SIN K 135°F MODEL FACTOR s1°c GL2815 2.8 X GL4215 4.2 X UPRIGHT GL5615 5.6 X GL8115 7.8* X GL8118 8.1 X GL2801 2.8 X GL4201 4.2 X PENDENT GL5601 5.6 X GL8101 7.8* X GL8106 8.1 X VERTICAL GL5632 5.6 X SIDEWALLt GL8133 8.1 X GL2826 2.8 X HORIZONTAL GL4226 4.2 X SIDEWALL§ GL5626 5.6 X GL8127 8.1 X CONVENTIONAL GL5624 5.6 X (OLD STYLE) GL8125 8.1 X 2 FINISHES AVAILABLE ON SPECIAL ORDER 3 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER 155°F 175°F 200°F 286°F NYC -DOB 68°C 1s0c 93°c 141°c cULus F.M. LPC CE MEA 101-92-E X X X X X -----X X X X X X ----X X X X X X X X X X X X X X X X ---X X X X X X X X X X X X X X X ----X X X X X X -----X X X X X X X X X X X X X X X X --X X X X X X X X X X X X X X X X ---- X X X X X ------- X X X X X ------X X X X X X -----X X X X X X X ----X X X X X X -------- X X X X ------X X -- X X X X ---X X - § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity -Wrenches -P/N 325390 (1/2"); P/N 312366 (LO.) FIRE SPRINKLER CORPORATION DECEMBER 2006 PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. *1/2" NPT. GLOBE!SJ PRODUCT WA RRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #6 RECESSED ESCUTCHEONS AND COVER PLATES FIRE SPRINKLER co:RPORATION TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C, D, & E RECESSED ESCUTCHEONS 2 PC RECESSED 1 /2" Adjustable • Finish/Part No. 1/2" NPT Chrome: 326201 White: 326203-W /4" tustable • Finish/Part No. 1/2" NPT ~hmme: 326170 W ite-326172-W Finish/Part No. 3/4" NPT Chrome: 326208 White: 326210-W Finish/Part No. 3/4" NPT Chrome: 326177 White: 326179-W 1/2" Adjustable Recessed Model Numbers • cULus Approved: 2810,4110,4210,4230,4231, 4234,4710,5628,5630,5631,8101,8107,8128,8129, 8151 & 8174 .cULUs & FM Approved: 5601,8106, 8156 & 5635 3/4" Adjustable Recessed Model Numbers Seismic • cULus Approved: 2801,2826,2851,2870,4201,4226, 4231,4251,4270,5601,5602,5626,5628,5635,5636,5641, 5642,5652,5670,5680,5685,5686,8101,8102,8152,8106, 8107,8109,8127,8128,8129,8135,8141,8157,8159,8171, 8174,8179,8185 •cULus & FM Approved: 5651, 8156, 8151 & 5679 • FOR FULL DESCRIPTIONS SEE PAGES: A-24-EQ, A-41-EQ, A-55-EQ, A-67-EQ, A-76-EQ & A-90-EQ CONCEALED COVER PLATES For "The Inch" Quick Response GL5606& Standard Response GL5653 • Finish/Part No. 135° Chrome: 332821 White: 332822 • Finish/Part No. 155° Chrome: 332827 White: 332828 • cULus Approved: GL5653 -135°F (57°C) with plate 135°F (57°C); 155°F (68°C) with plate 135°F (57°C); 155°F (68°C) with plate (68°C); 175°F (79°C) with plate 155°F (68°C); 200°F (93°C) with plate 155°F (68°C) OPTIONAL IBC SEISMIC RECESSED ESCUTCHEON OPTIONAL 4 1/2" diameter WHITE ADJUSTABLE CONCEALED COVER PLATE • FOR FULL DESCRIPTIONS SEE PAGES: A-38-EQ, & A-69-EQ MAY 2009 BULLETIN: EQ ESCUTCHEON B-3 TO ATT STREET CI1Y PHONE INDUSTRIAL FIRE SPRINKLER CO., INC. 3845 IMPERIAL AVE., SAN DIEGO, CA, 92113 C-16 558084 Phone (619) 266-6030 Fax (619) 266-6035 Carlsbad Fire Department I STATE I I ZIP I I FAX I GENTLEMEN: WE ARE SENDING YOU { 181 HEREWITH 0 UNDER SEPARATE COVER VIA 0 PRELIM. DRAWINGS 181 PRINTS 0 APPROVED PLANS DATE 12-4-13 I JOB# I 13-?so JOB Labrum Wealth TI-Bressi Ranch ,, STREET CITY I STATE I I ZIP I PHONE I FAX I } THE FOLLOWING ITEMS: 0 SAMPLES 181 MATERIAL CUT SHEETS 0 CALCULATIONS 0 SAFETY DATA SHEETS 0 COPY OF LETTER 0 OTHER: QUANTITY SHEETS DESCRIPTION 3 1 Bressi TI Piping Plan (sheet 1 of 1) 1 3 Material cut sheets (Globe Quick Response sprinklers, Globe seismic escutcheon) THESE ARE TRANSMITTED: 181 FOR APPROVAL . 0 FOR YOUR USE O AS REQUESTED 0 FOR REVIEW AND COMMENT 0 OTHER 0 DISTRIBUTION TO ARCHITECT O DISTRIBUTION TO MEP TRADES REMARKS: CC: FROM: Kira Sandage SIGNED: ______________ _ IF ENCLOSURES ARE OTHER THAN INDICATED, PLEASE CONTACT OUR OFFICE AT ONCE. __ --{ Deleted: AS130217