HomeMy WebLinkAbout6112 INNOVATION WAY; ; AS130127; Permit7/28/22, 12:56 PM AS130127 Permit Data City of Carlsbad Sprinkler Permit Job Address: 6112 INNOVATION WY Permit Type: SPRINK Parcel No: 2132621321 Lot#: 0 Reference No.: Permit No: AS130127 Status: APPROVED Applied 7/30/2013 Approved : 7 /31/2013 Issued: 7/31 /2013 PC #: Inspector: Project Title: CAMBRIDGE T.I. INSTALL NEW TENANT PIPING AND SPRINKLERS . LIGHT HAZARD OCCUPANCY WITH SPACING FOR NEW OFFICE Tl. Applicant: Owner: INDUSTRIAL FIRE SPRINKLER CO INC 3845 IMPERIAL AV SAN DIEGO CA 619-266-6030 619-266-6035 about:blank PALOMAR AIRPORT ROAD LLC C/O RYAN CO US INC/M JINDRA 50 S 10TH ST #300 MINNEAPOLIS MN 1/1 . Contractor's Material and Test Certificate for Aboveground Piping AS\~t21- PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving aulhoritv's requirements or local ordinances. Property name: Date 0 A-111 n ,-; C> c-. ti -r. ( -J'f.1 ·-·~ l .. "'2,c/3 Address: (!, fe(j;j{!,fll) I/ l / -z._ I 11/ /VO V ~ J-.t..:> ,,-, VVAt,f -+ l-J?l Accepted by approving authorities (names): ' 0 kr J,.-5> 8 ,4-0 F-iL€ f}eyT Address: P ,,tht.-14-o • .a.<, 1 iv~ Plans Installation conforms to accepted plans ' ~YES □ NO Equipment used is approved ~ES □ NO If no, explain deviations Has person in charge of fire equipment been instructed as [lV'YES □ NO To location of control valves and care and maintenance Of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? ii ~ES □ NO I. System components instruction YES □ NO 2. Care and maintenance instructions ~ES D NO 3. NFPA#25 YES □ NO Location of Supplies buildings: system YEAR OF ORIFICE TEMPERATURE MAKE MODEL MANUFACTURER SIZE QUANTITY RATING C:;; l,,n tl P /-. 1 .:::,/,,, 0 I ~ '-'17 1 /,., --7_ "3 IS,:;, SPRINKLERS 0 0 PIPE AND Type of pipe Sched 10/40 FITllNGS Type of fittings Ductile/Cast iron threaded Grooved MAXIMUM llME TO OPERATE Al.ARM VALVE AlARM DEVICE --THROUGH TEST CONNECTION OR FLOW TYPE MAKE (MODEL _/ MINUTES SECONDS INDICATOR VANE ( VSR-SF __,) 0 45 p ... fr~/1-- HYDROSTATIC: Hydrostatic tests shall be made al not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure TEST in excess of 150 psi (10.2 bar) for 2 hours. Differential dry-pipe valve clappers shall be left open during the test to prevent damage. All DESCRIPTION aboveground piping leakage shall be stopped. 9-13 -2-0 /3 HYDROSTATIC TEST: ALL PIPING TESTED AT 200 PSI FOR 2 HRS TESTS lF NO EXPLAIN '\ 1.f > BELL TEST: ALL BELU TESTED THRU INSPECTORS TEST. IF NO EXPLAIN L,f e> HYDRAULIC NAMEPLATE PROVID~· ~ IF NO EXPLAIN: DATA ~ YES ·, □ NO REMARKS DATE LEFT IN SERVICE WITT{ ALL CONTROL VALVES OPEN I U -71--zo /;> ____ ,, ,,,,.-::. NAME OF SPRINKLER CONTRACTOR:<JNDUSTRIAL FIRE SPRINKLER CO. INC. 619-260-ou.>u _/ TESTS WITNESSED BY FOR ~RTY OW~NED) TITLE: DATE: SIGNATURES /d .> ~A-V f · JO -3/-/-'j FOR-SPRINKLER CONTRACTOR (SIGNED) TITLE: I DATE: ADDITIONAL EXPLANATIONS AND NOTES: