HomeMy WebLinkAboutCUP 01-20; NEXTEL - RANCHO CARLSBAD; Site Plan.._
~
'-
i
~
() {
~'l:J.
I I
""-----1 ~ t %
~ ~ I I I
I I
I I
I I I I I
I
I
I
I
I
I
+
I //. I ,
I I I
I
'
i
'-, r-~
/--,-
l!lCISfflG PAAKJN(I
(7 11111111111 n 11111 1
1U n I I I I llTl.1lJTTTn I
le-.·. . SECTOR I
I Lf
I 920° t~ ~·'n-____:'-r------LL---_____J---==-...i....;~_*~____:_~ ~j
\
PROPOSED • A PANEL
-~7
>--~114 1-e.11 [
I I
'
ANTENNA!:> FACADE MOUNTED
ON EXl5TINcS SUILDINcS
----, !TYPICAL OF 4 ANTENNAS) 1---~
(ANTENNAS PAINTED TO
MATCH EXISTINcS SUILDINcS)
l!XllfflNQ IUI..DINB
PROPOSED -PW PANEL
~-ANTENNAS MOUNTED 5EHIND
/
EXISTINcS ¾REEN ~LL
(TYPICAL OF 4 ANTENNAS)
I .I
//
5ECTOR9
240'
(
I
l
ITIT1nn nrr111l,,--~rr urru inn lrrn r
rUWJlJJULn 111 / I I 111 r _,..,._
I
PROPOSED~ EGUIPMENT
SUILDINcS (SHOl"lN SHADED)
,,--t----t------J /MATERIAL AND COLOR TO
MATCH EXISTINcS SUILDINcS)
SEE SHEET A-2 FOR
/-t--,"----,---,------t ENLARcSED FLOOR PLAN I "'~ .. ,-
1
I
I
I
I .,, I
rn \ I\
\ \
I
I
I
o\ g\
la\
\
lWilWJJJ1111 I I 11111 11 ~✓-\
ilil ' r111 1 11 1 1 1 1 11 IW 111111 ~ ~L....L.jtW 1111111_
\\
"----
\
[ NOTE
SITE PLAN CD THE BUILDINcS DATE LE:<So!:ND STATINcS THAT YAl'tDS
USED FOR Al'itf:A I NCl'tE:ASES SHALL 6E PERMANENTi. Y
MAINTAINED
@ "ALL P1'tOPERTY LINES, EASEMENTS AND 5UILDIN<SoS,
50TH EXISTIN6 AND PROPOSED, ARE SHON-l ON THIS
SITE PLAN
GENERAL NOTES
I, ALL i'lOFtK $HALL COMl"L Y l'tlTH THE FOLLOl'tlNcS Al"PL.ICABLE CODES.
l"i"if> CALIFORNIA 5UILDINcS CODE (C6C!
4 SUILDINcS CODE AMENDMENTS
l'l'l"T UNIFORM SUILDINcS CODE STANDARDS, VOLUME a
l'l'lf> CALIFORNIA ELECTRICAL CODE
l"i'lf> CALIFORNIA FIRE CODE
2. et.eCTRICAI. 5YSTeM ~ 1'!: ISROUN~ Pelt N!:.C. AATICLI!: :2!50 AMP 1eo.
a. EXHAUST FANS MUST 5E DUCTED TO EXTEFl.1""-
I SPECIAL INSPECTION
• 5+101" l'f:LDINcS SEE DETAILS 55/DS, l>"T/D4, "T2/D4 AND f>O/D4
NOTE, ALL SPECIAL INSPECTIONS SHALL eE l"EFI.FORMED 5Y CITY 01"
CARLSBAD CERTIFIED SPECIAL INSPECTOFI.S. SEE LIST OF
APFFI.OVED SPECIAL INSPECTION/MATEF<IAL TESTINcS AcSENCIE!>
SPECIAL INSPECTION NOTE:
• WELDING
I. A CEFI.TIFICATE OF SATISFACTOf'tY COMPLETION OF l"lOFI.K REGUIF<INcS
SPECIAL INSPECTION MUST BE COMPLETED AND SUBMITTED TO THE
FIELD INSPECTION DIVl510N.
2. AN Al"l"LICATION l"OR OFFSITE l"AeRICATION Mt.eT 5E !ll.J15MITTED TO
THE FIELD INSPECTION DIVISION FOR APPROVAL PRIOR TO
FABRICATION.
a. A CERTIFICATE OF COMPLIANCE FOR OFFSITE FAeRICATION MUST ee
COMPLETED AND SUBMITTED TO THE FIELD INSPECTION DIVISION PRIOR
TO ERECTION OF PREFABRICATED COMPONENTS.
4. l'Cl!!LDS ID!!NTIFIED AS REGUIRINe CONTINUOUS 01'1: l"ERIODIC SPECIAL
l~PECTION NEED NOT HAVE SPECIAL l~ECTION 1-'lHEN THE l'IELDIN6
IS DONE IN A FABRICATOR'S SHOP APPROVED AND Rl:cSISTERED BY THE
CITY OF SAN DIE60. HOl'IEVER, THE APPROVED FABRICATOR MUST
SUBMIT A CERTIFICATE OF COMPLIANCE IN ACCORDANCE 1-'llTH CSC
SECTION 1101.1 . 1-'lHEN 1-'lELDING-IS DONE IN A SHOP 1-'lHICH IS NOT AN
APPROVED FABRICATOR; SPECIAL IN5FECTION IS REQUIRED AND AN
Al"l"LICATION TO PERFORM OFF-SITE FABRICATION MUST 13E !illl5MITTEt,
TO AND APPROVED 6'T' THE FIELD INSPECTION DIVISION.
~~~~~~~~-~
~I FIRE PROTECTION NOTES I
I. NEXTEL SHALL SE:CURE: PERMIT!:> "E:GUIRED 15Y THE CITY
OF CARLSBAD 5UILDINcS DE:PARTMENT FROM THE CITY
OF CARLSBAD FIRE CHIEF PRIOR TO INSTALLATION
:2. PLANS FOR ALL FIXED FIRE PROTECTION EGUIPMl!:NT
SUCH AS STAND-PIPES, SPRINKLER SYSTEMS AND FIRE
ALARM SYSTEM MUST BE SUBMITTED TO AND
APPROVED 13Y THE CITY OF CARL5AD FIRE CHIEF
6EFORE THIS E:OUIPMENT IS INSTALLED
5. BUILDIN6!$ UNDEF<601NcS CONSTUCTION, ALTERATION OR
DEMOLITION SHALL BE IN ACCORDANCE: 1-'llTH CFC
ARTICAL e1. [ CFC § e101 )
4. AT LEAST ONE FIFI!: EXTIN61Jl!:>HER Y'(ITH A MINIMUM
RATINcS OF 2-A-IOB,C SHALL SE PROVIDED 1-'llTHIN 15
FEET MAXIMUM TRAVEL DISTANCE FOR EACH t,poo
5GlUARE FEET OR PORTION THEROF ON EACH FLOOR.
[ CFC, § 1002, UFC, STENDARD 10-1, CALIF. CODE OF
REcSS, TITLE 1"1, § !3.2'1 )
!. COMPLETE PLANS AND SPECIFICATION FOf't FIRE:
ALAFI.M SYSTEMS; FIRl:-1:XTIN<SoUISHINcS SYSTEMS,
INCLUDIN6 AUTOMATIC SPRINKLERS AND OTHEFI.
FIRE-PROTECTION SYSTEM!:> SHALL eE SUBMITTED TO
FIRE AND LIFE SAFETY FOR REVIEY'( AND APPROVAL
PRIOR TO INSTALLATION.
[ C,FC, § 1001.9 )
-~_/'._~-~~-/'-..~__,A..._/'..__/
APPROVE:D
nllS II 1111! AlftOYlD'RlNF1~A! W..'lffflE
Pl.AN PER CONDfflON NO. ,6 OF PLA NNINO
COMMISSION IU!SOltJ1iiN?OC>. -~6'(_
~ '/:'""-cJ,,,_.. ~ 1-,.,..01... lliq;t11ec:rins Dept. -,.__,~~.~-o;.
~RCHITECTURE .. .. PL~NNING
WILllAl'I i'I BOOTH llf!.CHITECT f!.O0El'.T J. SURMZ Af!.CHITECT
,.O.llOX 4051. CIII\LSIIAD,CA. 9101& (700) 434·84?'-'I
======= :: =======
PREPARED FOR
__ I
NEXTEL OF CALIFORNIA
5761 COPLEY DRIVE, SUITE 100
SAN DIEGO, CALIFORNIA 92111
(858) 650-4250
FAX: (858) 650-4202
=====II======
PROJECT NAME
RANCHO CARLSBAD
PROJECT NUMBER
CA7-435A
5545 FERMI COURT
CARLSBAD, CA 92008
SAN DIEGO COUNTY
======== .. ..
APPROVALS
PROJECT MANAGER DATE
NEXTEL REVIEW DATE
RF REVIEW DATE
OWNER REVIEW DATE
======= :: =======
DRAWING DATES
10/5/01 PERMIT SUBMITTAL (WB)
11/19/01 &CITY REVISIONS (RAL)
======= 11 =======
SHEET TITLE
SITE PLAN
CUP Ql-2.-0 ..
PROJECTS\NEXTEL\01095cd\01095cA1 .OWG
======= == =======
A-1