HomeMy WebLinkAboutCUP 01-27; FOUR SEASONS RESORT PBW; Site PlanEXISTING PRIVATE DRIVE
"""'--~:UR SEASONS POINT
PROPOSED NEXTEL TELECOM _ _,,
FACILITY
PROPOSED VERIZON TELECOM _ _,,
FACILITY
-----------
• •
\ \
;--EXISTING RESORT
/ (TYPICAL)
BUILDING-~
•
BOUNDARY NOTE:
THE PROJECT BOUNDARY SHOWN ON THIS DRAWING IS
APPROXIMATE AND IS SHOWN FOR REFERENCE ONLY. A
BOUNDARY SURVEY WAS NOT PERFORMED BY CHRISTENSEN
ENGINEERING AND SURVEYING
SITE PLAN
SCALE: 1" • 80'· fY'
S 38' 56' 54" E 103.14'
PROPERTY LINE (TYPICAL)
SECTOR A o· I
I
PROPOSED CINGUIAR WIRELESS ANTENNAS MOUNTED
INSIDE A NEW "TELEFLAGE" EXTENSION TO AN EXISTING
PLASTER PLATFORM ON THE ROOF OF THE EXISTING
RESORT STRUCTURE. SEE ROOF PLAN SHEET A-1
·---......__......__ ___ SECTOR 8 • 120'
PROPOSED CINGULAR WIRELESS BTS
EQUIPMENT CABINETS ON AN EXISTING
CONCRETE LANDING ON THE FIFTH FLOOR
OF AN EXISTING BUILDING (SHOWN SHADED)
PROPOSED CINGULAR WIRELESS ANTENNA MOUNTED
INSIDE THE WALL OF THE EXISTING BUILDING. SEE
ROOF PLAN SHEET A-1
-~
~......._
·-....
• o~/ ,if! ~,
"' ---~
• •
---~
-· EXISTING RESORT COMPLEX
AND FACILITIES
~ EXISTING GOLF COURSE
--------
~-1-. ~ PROPOSED SPRINT TELECOM
FACILITY
44 .. E 155.98'
N 44' 51' •• -_.:;..._-?'-,._ "" ""-N 77 15' 55" W 26.84'
GENERAL SPECIFICATIONS
I. TH[ LATES'T EDITION OF THE AME~ICAN IN!lTIT\JTE or ARCHITECTS OOCUME:NT
A20I "GENER~ CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" ARE
INCLUDED IN THESE SPECIFICATIONS >:5 IF COMPLETELY REPRODUCED HEREIN.
2. THIS FACILITY IS AN UNOCCUPIE:D PCS TELECOMMUNICATIONS SITE AND IS
E:XEMPT FROM DISABLED ACCESS REQUIREMENTS.
3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS PARTICIPATING
SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL
CONDmONS AFFECTING Tl-IE PROPOSED PROJECT, WITH THE CONSTRUCTION
AND CONTRACT DOCUMENTS, FlELD CONDITIONS ANO CONFlRM THAT THE
PROJECT CAN BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH
CONSTRUCTION. SHOULO ANY ERRORS, OMISSION, OR DISCREPANCIES BE
FOUND, THE GENER~ CONTRACTOR SHALL IMME:DL>\TELY NOTIFY CINGUl.611
WIREUSS PROJE:CT MANAGER ANO THE ARCHITECT IN WRITING. IN THE
EVENT OF DISCREPANCIES THE CONTRACTOR SHALL INCLUDE THE MORE
COSTLY OR EXTENSIVE WORK IN THE BID, UNLESS SPECIFlCALLY DIRECTED
OTHERWISE. IF A DISCREPANCY EXISTS AND THE PROJECT MANAGER AND
ARCHITECT ARE NOT NOTIFIED, THE GENER~ CONTRACTOR SHALL BE: HELD
RESPONSIBLE FOR ALL COSTS INCURRED TO REPAIR OR CORRECT ALL
PROBLEMS THAT RESULT.
4. DRAWINGS SHALL NOT BE SCALED. FlGURED DIMENSIONS HAVE
PRECEDENCE OVER DRAWING SCALE AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK
ACCURACY OF ALL OIMENSIONS IN THE FlELO. UNLESS SPECIFICALLY
NOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN ANY CONSTRUCTION
UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAS BEEN VERIFIED
AGAINST ACTU~ FlELD DIMENSIONS.
~-CONTRACTOR SHALL NOTIFY THE CINIIUl..lft Wlftl!LESS PROJECT MANAGER
AND THE ARCHrTECT IF Alf'/ DETAILS ARE CONSIDEREO IMPRACTICAL,
UNSUITABLE, UNSAFE, NOT WATERPROOF. OR NOT WITHIN CUSTOMARY
TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT
THERE IS NO OBJECTION TO Alf'/ DETAIL DETAILS ARE INTENOED TO SHOW
THE E:ND RESULT ~ THE DESIGN. MINOR MODIFlCATIONS MAY BE
REQUIRE:D TO SUIT JOB CONDITIONS. AND SHALL BE INCLUDED AS PART OF
THE WORK.
&. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY
THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE
SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE CINGULAR
WIRELESS PROJECT MANAGER AND THE ARCHITECT SO THAT MODIFICATIONS
CAN BE t.lAOE BEFORE PROCEEDING WITH THE WORK.
7. ALL SYMBOLS AND ABBREVL>\TIONS USED ON THE DRAWINGS ARE
CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS
QUESTIONS REGARDING THEIR OOCT MEANING, THE CINGUl.611 WIRELESI
PROJECT MANAGER ANO THE ARCHITECT SH~L BE NOTIFIED FOR
CLARIFICATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK.
e. THE CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS. LICENSES ANO
INSPECTIONS NECESSARY FOR PERFORMANCE OF THE WORK AND INCLUDE
THOSE IN THE COST OF THE WORK TO CINOLI.AR WIREI..ESS
9. THE CONTRACTOR SHALL SUPERVISE ANO DIRECT ALL WORK, USING HIS
BEST SKILL ANO ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, MITHODS. TECHNIQUES, PROCEDURES ANO
SEQUENCES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER
THE CONTRACT.
10. WORKMANSHIP THROUGHOUT SHALL BE OF THE BEST QUALITY OF THE
TRADE INVOLVED, AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM
REFERENCE STANDARDS FOR QUALITY AND PROFESSIONAL CONSTRUCTION
PRACTICE:
NRCA NATIONAL ROOFING CONTRACTORS ASSOCL>\TION
O'HARE INTERNATIONAL CENTER
10255 w. HIGGENS ROAD, SUITE eoo
ROSEMONT, IL 60018
SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS
NATION~ ASSOCIATION
4201 LAFAYmE CENTER DRIVE
CHATILLY, VA 22021-1209
ITLP INTERNATIONAL INSTrTUTE FOR LATH AND PLASTER
820 TRANSFER ROAD
ST. PAUL, MN 55114-1406
AMA >IOHESIVE MANUFACTURERS ASSOCIATION
401 NORTH MICHIGAN AVENUE, SUITE 2400
CHICAGO, IL 60611
11. THE CONTRACTOR SHALL VERIFY, COOROINATE, AND PROVIOE ALL
NECESSARY BLOCKING. BACKING, FRAMING, HANGERS OR OTHER SUPPORTS
FOR ALL ITEMS REQUIRING THE SAME.
12. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL COMPLY WITH ALL
LOCAL CODES, REGULATIONS. AND ORDINANCES AS WELL AS STATE
DEPARTMENT OF INDUSTRIAL REGULATIONS AND DIVISION OF INDUSTRIAL
SAFE1Y (OSHA) REQUIREMENTS.
U THE CONT-TOR SHALL f'IIOTECT THE PROPEIITY OWNERS, ANO CINCULAI!
WIRELESS PROPER'lY FROM DAMAGE WHICH MAY OCCUR DURING
CONSTRUCTION. ANY DAMAGE TO NEW ANO EXISTING CONSTRUCTION,
STRUCTURE, LANDSCAPING, CURBS, STAIRS, OR EQUIPMENT, ETC. SHALL BE
IMMEDL>\TELY REPAIRED OR REPLACED TO THE SATISFACTION OF CINGUl..lft
WIRELESS, OR THE PROPERTY OWNER, OR THE OWNER'S REPRESENTATIVE.
AT THE EXPENSE OF THE CONTRACTOR.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REPLACE OR
REMEDY, Alf'/ FAULlY, IMPROPER, OR INFERIOR MATERI= OR
WORKMANSHIP OR Alf'/ DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR
AFTER THE COMPLETION AND ACCEPTANCE ~ THE WORK BY CINOULAI! WIRELESS UNDER THIS CONTRACT.
15. IT SHALL BE THE RESPONSIBILITY OF THE OEN£1'W. CONTRACTOR TO
LOCATE ALL EXISTING UTILITIES, WHETHER SHOWN HEREIN OR NOT, ANO TO
PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BE'.AR ALL
EXPENSES FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER
PROPERTY DAMAGED IN CONJUNCTION WITI-l THE EXECUTION OF WORK.
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOO THE COMPLETE SECURfTY
~ THE PROJECT SITE WHILE THE JOB IS IN PROGRESS ANO UNTIL THE
JOB IS COMPLETED AND ACCEPTED BY CINOULAR WIRELESS
17. THE CONTRACTOR SHALL PROVlOE TEMPORARY WATER, POWER AND TOILET
FACILITIES AS REQUIRED BY THE PROPERTY OWNER, CINOUl.611 WIRE
LESS, AND THE CITY OR GOVERNING AGENCY.
18. THE LATEST E:DITION OF ALL PERMITTED AND APPROVEO PLANS PERTAINING
TO THIS PROJECT SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE
USED BY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME
INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD
CONDITION, ONE: COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA
ANO CHANGE ORDERS ON THE PREMISES AT ALL TIUES. THESE ARE TO
BE UNDER THE CARE OF THE JOB SUPERINTENDENT.
19. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS ON
A DAILY BASIS, ANO SHALL EXERCISE STRICT CONTROL OVER JOB CLEANING
THROUGHOUT CONSTRUCTION, INCLUDING FINAL CLEAN-UP UPON
COMPLETION OF WORK. ALL AREAS ARE TO BE LITT IN A BROOM CLEAN
CONDITION AT THE: ENO OF EACH DAY.
20. THE GENERAL CONTRACTOR MUST PERFORM WOOK DURING PROPERTY
OWNER'S PREFERRED HOURS TO AVOID DISRUPTION OF NORt.lAI. ACTIVrrY.
21. ~L EXPOSE:D MET~ SH~l BE HOT-DIPPED GALVANIZE:D.
22. S~ ALL JNETRATIONS THROUGH FIRE-RATED AREAS WITH U.L. LISTED OR
FlRE MARS~LL APPROVED MATERIALS IF AND WHERE APPLICABLE TO THIS
FACILilY AN PROJECT SITE.
23. PROVlDE A ORTABLE FlRE EXTINGUISHER WrTH A RATING OF NOT LESS
THAN 2-A R 2-A 1 OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL
PORTIONS O THE PROJECT AREA CONSTRUCTION.
24. ELECTRICAL WER SYSTEM SHALL BE GROUNOEO PER NEC ARTICLES 250
AND 810.
25. ALL NEW O ENINGS IN THE: EXTERIOR ENVELOPE ~ CONDITIONED SPACES
SUCH AS A WALL ANO ROOF PENETRATIONS SHALL BE CAULKED OR
SEALED TO MIT INFlLTRATION OF AIR AND MOISTURE.
211. UPON COMP N OF CONSTRUCTION, CINOUl..lft Wlll!L!!S PROJECT
MANAGER S L CONDUCT A WALK-THRU WITH PROPEERTY OWNER OR
REPRESENTA VE OF PROPERTY OWNER
PROPRIETARY INFORMATION
THE INFOR ATION CONTAINED IN THIS SET OF DESIGN DOCUMENTS IS
PROPRtETA~ BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT
WHICH REL,\TES TO CINGULAR WIRELESS IS STRICTLY PROHIBrTED.
H PLA~NING
1,.J lll4M M COCTH ilRCH"TfCT rv)Df1T J SUA~~z ~fl.(HITEC:"
~(') 8C'JX ~/.',1 CA11'"illfl/l. r:~ ','2~'.fl (7 1,0) ~~4 t\~7~
II
PREPARED FOR
:-: cingular
WIRELESS
6170 CORNERSTONE CT., SUITE 180
SAN DIEGO, CA 92121
======== II
APPROVALS
OPERATIONS DATE
R.F. DATE
ZONING DATE
CONSTRUCTION DATE
SITE ACQUISITION DATE
OWNER APPROVAL DATE
H
PROJECT NAME
FOUR SEASONS
PROJECT NUMBER
SD-366-03
7100 FOUR SEASONS POINT
CARLSBAD, CA 92009
SAN DIEGO
■■ ■■
DRAWING DATES
7/20/00
7/27/00
8/10/00
8/12/01
11/19/01
11/21/01
PRELIM ZD REVIEW
ZD REVISIONS
ZD SUBMITTAL
ZD SUBMITTAL REVISIONS
ZD SUBMITTAL REVISIONS 2
ZD SUBMITTAL REVISIONS 3
n
SHEET TITLE
SITE PLAN
H
PROJECTS\PBW\0011 Ozd\0011 OzAO.DWG
II
A-0
NI
'4. • .,c ~
ti:)
t\.
t,. " I<'\ " • ,(. Ill
0 ~ \ "I
~ ~ • ~
't
I'( 1//
..!, V)
i ~ l' ~ 4. '1
APPI-.tOVEll
nns IS nm APPROVED TENTATIVl! MAP!SITE
Pl.AN !'ER OClN')!'f'":)Y NO. b Ol' PLANNING
COMMISSION !L'lilOLU"ITON NO. .5/ k ( __ .
ANTENNA A1
AZIMUTH 0' •
C ·.· -:µ,::1 -
------------------------[ff . IP . .,......_· "-H-
= = .=,
·'b ---·_•-_-J>.~
I I ' ---=H-"-~~
~rr'-1+'1..!--1--t"-_!,..,
' -~-.... ,)/_ -~
~ ~-
ANTENNA AND COAXIAL CABLE SCHEDULE
SECTOR DIRECTION AZIMUTH ANTENNA MODEL NUMBER DOWNTILT SERL<\L NUMBER
ANTENNA
A1 NORTH O" EMS WIRELESS 65-l 8-04DP o·
81 SOUTHEAST 120' EMS WIRELESS 65-l 8-04DP o·
C1 SOUTHWEST 240' EMS WIRELESS 65-l 8-04DP o·
NOTES:
1. FIELD VERIFY ALL CABLE LENGTHS PRIOR TO ORDERING CABLE
2. VERIFY ROUTE AND LENGTH OF CABLE PRIOR TO CUTTING. ADJUST INDICATED ROUTE
AS REQUIRED TO CLEAR EXISTING OBSTRUCTIONS AND MAINTAIN REQUIRED CLEARANCE OF EXISTING EQUIPMENT,
3. VERIFY MODEL NUMBER OF ANTENNA WITH CINGULAR WIRELESS.
PROPOSED CINGULAR WIRELESS ANTENNAS INSIDE A NEW
"TELEFLAGE" EXTENSION TO AN EXISTING PLASTER PLATFORM.
SEE ELEVATIONS SHEET A-3
18" EXTENSION '-'"'··. --"'4lac-l--,Hc-,H,.l -~ ANTENNA 81
• AZIMUTH 120'
I ' ' . I I I 1
I ' ' 12d >: I
' I
j, I
I • I
PROPOSED COAXIAL CABLE TRAY
MOUNTED INSIDE ATTIC SPACE DJ.,,.. __ _J
EXISTING MECHANICAL EQUIPMENT
PROPOSED COAXIAL CABLE TRAY ____.,,.
MOUNTED ON UNISTRUT MOUNTED TO
INSIDE FACE OF PARAPET WALL
EXISTING PARAPET
EXISTING BUILT-UP ROOFING
--
PROVIDE " TRAF-WALK" PADS-~
TO PROPOSED LNA LOCATIONS
PROVIDE YELLOW REFLECTIVE TAPE-,-_
ON EACH SIDE OF ''TRAF-WALK"
PAD PATH
I I
' I '
I ., I
I
' ,I
PARTIAL ROOF PLAN • ICAI.E: 118" • 1'-G"
ANTENNA C1
AZIMTH 240'
~~-3±
' ' ' . t
'
' ' r
' ' ' t:t,ttitti::o:xt' i r
PROPOSED CINGULAR WIRELESS BTS EQUIPMENT CABINETS ON
AN EXISTING CONCRETE LANDING ON THE FIFTH FLOOR
BELOW (SHOWN SHADED). SEE SHEET A-2 FOR AN
ENLARGED PLAN OF THIS AREA
LINE OF EXTERIOR WALL BELOW
~------' PROPOSED CINGULAR WIRELESS ANTENNA MOUNTED INSIDE AN
EXISTING WALL
EXISTING FASCIA
EXISTING TILE ROOF
COAY.. CABLE JUMPER COAX SIZE
LENGTH LENGTH
(+ / -5') (+ / -3')
95' 10' 7/8"
95' 10' 7/B"
40' 10· 7/B"
ARCHITECTU~E .. .. PLANNING
w LLIFM M C<OOT~ APCH HCT ~,-::'.lDEP,T J su,PEZ f'P,CHITECT
~O BOX ~651 CAl\LSBfD CA 9'!')18 (7t0) ~J~ 8'74
.. ..
PREPARED FOR
:-: cingular
WIRELESS
6170 CORNERSTONE CT., SUITE 180
SAN DIEGO, CA 92121
.. ..
APPROVALS
OPERATIONS DATE
R.F. DATE
ZONING DATE
CONSTRUCTION DATE
SITE ACQUISITION DATE
OWNER APPROVAL DATE
n
PROJECT NAME
FOUR SEASONS
PROJECT NUMBER
SD-366-03
7100 FOUR SEASONS POINT
CARLSBAD, CA 92009
SAN DIEGO .. ..
DRAWING DATES
7/20/00
7/27/00
8/10/00
8/12/01
11/19/01
11/21/01
PRELIM ZD REVIEW
ZO REVISIONS
ZD SUBMITTAL
ZD SUBMITTAL REVISIONS
ZD SUBMITTAL REVISIONS 2
ZD SUBMITTAL REVISIONS 3
======== :: ========
SHEET TITLE
PARTIAL
ROOF PLAN
======== :: ========
PROJECTS\PBW\0011Ozd\0011 OzA1 .DWG
.. ========= ..
A-1
I(.
t
f'f) OUTLINE OF 'TELEFLAGE" RF TRANSPARENT PANEL
IN FRONT OF ANTENNA,
TEXTURED AND PAINTED TO MATCH
EXISTING ADJACENT WALL SURFACE
PROPOSED CINGULAR WIRELESS BTS EQUIPMENT CABINETS ON
PROPOSED CINGULAR WIRELESS ANTENNA MOUNTED INSIDE
AN EXISTING CONCRETE LANDING ON THE FIFTH FLOOR.
SEE SHEET A-2 FOR AN ENLARGED PLAN DF THIS AREA THE WALL OF EXISTING BUILDING. ;
I I -I 1 10 , I \TOP OF ROOF
I A4 1 I I I ~
-PROPOSED CINGULAR WIRELESS ANTENNAS INSIDE A NEW r 11 , "TELEFLAGE" EXTENSION TO AN EXISTING PLASTER PLATFORM.
~y SEE ROOF PLAN SHEET A-1
TOP OF EXISTING ELEMENT -I fffr I ' I \ TOP OF ANTENNA
-~ ~ ~ / ~ ~ • ' ! . ' I 11 I C [['l . ' I 11 I
[•1i\li~
. -,
y: -' :,-' ' ' ' ' LI "' r .;-,, ' r ' ' ' , r . --' ' ' ' ' -. ---, :r • -' . ' --' --· ~ C ~ ~
-• C
C
,J__ 56'-0" '
\ TOP OF "TELEF~GE" EXTENSION
• ....
T TOP OF ' . ',, • ' <O "CHIMNEY" " -.. 111v I
~Ill -:..-
' r ' • r -LT -r . ;;
e!Hc ' ' . ' ): ' • " ' -r ' ~ ' ~ . ---};. r r . ' -:( j --, ' r r ' c, c, '" C ~ ~ ~ ----------------
-I-I-I-I-I-I-I-D m -I-I-I-I-I-I-I-
~ 1ffi -■ 111111,111111 .
m ---,-------I-I-I-I-
I-I--1--1-H-_,_ --
]11111111 -I Il[ mil [[II
'
----------. ---------
D :____J_ -1-----m '---I-I-I-I-I-• I [llI ____ EXISTING GUARDRAIL 0
IllIIII II I II I -{TYPICAL) • "' <O "' --I -;,, ---D EB "' ------------I-I-I-I-I-
m I-I--I--I-I-I-I-I-I-I-,__ --------t--1-i
• JIIIlilill I ■ I 1,1 ■ 0 • I <O
(!) I
"' -... ·-·--
"' [B I-I--I--I--I-I-I-I-I---------I-I-I-I--
Wl.l 1111 'WllllW 11111 "' llllJ Iii 1111 Ill . IJIIII" ""' I mill WII llll ; ~ illW II Wllll; llllJ
-0 0 EXISTING WINDOWS ----
(TYPICAL) ----------~ -------
~ -I--I--I---I--1--I-
D Ill 111111111
'
~ ' ~ ; ; ; I ~ \ ' --
\ .
C 0 0
I m -------------I -1---~ ----I--I-
L EXISTING PLASTER FINISHED
-r----------
STEEL STUD BUILDING II Ill 11mll rm Il ·■ I
I ~,,. .. . --·-·--···· ·-.
f-; i ~ ; ; f-
tE f-
. -----
.
'==
" 0"-0"
'
WEST ELEVATION
\
\. ____ EXISTING PLASTER FINISHED STEEL STUD BUILDING
'f' . GRADE
EAST ELEVATION
SCN.E: 119" • 1'· O" IICH.E: 1111" • 1"· O"
PROPOSED CINGULAR WIRELESS ANTENNAS INSIDE A NEW
PROPOSED BTS EQUIPMENT "TELEFLAGE" EXTENSION TO AN EXISTING PLASTER PLATFORM.
ON FIFTH FLOOR LANDING SEE ROOF PLAN SHEET A-1
~, EXISTING ROOF TILE
~ '' ' / -1111;
' 1111 r , ITTJ-
I -'
-' ' -' ----' -
' • ,. • ' ~ ---------------------
1-f-f-1-f-f-f-f--f--I-------------I-I-I-I-I-I-f-I--I--I--I-I-I-I-I-I-I-I-I-I-I-
I ITI I I 11 lllll g TI ' [[[I [fil I I I I
I I ------f-------I----I-I-I-I-I---I-I-LL
I-I-f-I-I-I-I : --.. --,---------~
II Ill I I [[[■I [[ill 11111 I I
/~ EXISTING PLASTER FINISHED STEEL STUD BUILDING
I
'
~ -----------. -f-----I-I--I--I--I-I-I-I-I--I--I-------,. -··---I--I--I-I-I-I-I--I--I----mII ~ I " """~ Willlilmllilill 11W mi; ;JJJJ);Wlt lllll 11111 l~ 1111 11111 WJJ11111 Ii 11W mm. I ilmW Wl1I
0 0 C 0 () 0 ' ' ,,,----EXISTING GUARDRAIL ~---------' =[J ~ / {TYPICAL) _,_ -I-------,--I-I--I--I-
-~ -I-1---+-~ /
v ..... -· ___ ,,,_ I-I--I--I--I-I-I-I-I--I-■ II 11111 rnn II ' -
1111 '
' I
--~ ,,_ .... " . -·---
.. ··-·--·-' .. ; ~ i ; ; ; ; ; ~ ; ; ~ . __ .,
SOUTH ELEVATION
8CAl.e: 119" • 1'· 0"
' ' '
A'\CHITECTURE ■■ ■■
11-0 UC 1; I
P./'.NNING
,;11.•IH I ARCIII ICCT
======== == ========
PREPARED FOR
:-: cingular
WI RE LE 55
6170 CORNERSTONE CT., SUITE 180
SAN DIEGO, CA 92121
II=====
APPROVALS
OPERATIONS DATE
R.F. DATE
ZONING DATE
CONSTRUCTION DATE
SITE ACQUISITION DATE
OWNER APPROVAL DATE
H
PROJECT NAME
FOUR SEASONS
PROJECT NUMBER
SD-366-03
7100 FOUR SEASONS POINT
CARLSBAD, CA 92009
SAN DIEGO
======== .. ■■
DRAWING DATES
7/20/00
7/27/00
8/10/00
8/12/01
11/19/01
11/21/01
PRELIM ZD REVIEW
ZD REVISIONS
ZD SUBMITTAL
ZD SUBMITTAL REVISIONS
ZD SUBMITTAL REVISIONS 2
ZD SUBMITTAL REVISIONS 3
======== == =======
SHEET TITLE
EXTERIOR
ELEVATIONS
======== == ========
PROJECTS\PBW\0011 Ozd\0011 OzA3.DWG
=====II=====
A-3