HomeMy WebLinkAbout2646 STATE ST; ; FPR2020-0142; PermitPERMIT REPORT Fire Permit Print Date: 08/24/2022 Job Address: 2646 STATE ST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: 2031012000 Track#: Valuation: $0.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: (city of Carlsbad Permit No: FPR2020-0142 Status: Closed -Finaled Applied: 12/24/2020 Issued: Finaled Close Out: 04/06/2022 Final Inspection: INSPECTOR: Cheung, Nathaniel Description: SEAGLASS -NEW DIGITAL ALARM COMMUNICATOR/TRANSMITTER CONTROL PANEL TO MONITOR SPRINKLER SYSTEM Applicant: FIRE ETC FRANCHOT DAVIS 2190 MAIN ST SAN DIEGO, CA 92113 (760) 859-7443 FEE FIRE Reinspection (per inspection) FIRE Reinspection (per inspection) FIRE Sprinkler Monitoring Total Fees: $769.00 Fire Department Total Payments To Date: $769.00 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov AMOUNT $193.00 $193.00 $383.00 $0.00 Page 1 of 1 SEA GLASS 2646 STATE STREET CARLSBAD, CA 92008 FIRE ALARM SYSTEM CONTRACTOR FIRE ETC. 2190 MAIN STREET SAN DIEGO, CA 92113 PH: (760) 672-5914 CA LIC. Cl0-1028927 TABLE OF CONTENTS ITEM QTY. PART# DESCRIPTION MANUFACTURER 1 1 SK-6700 Addressable Fire Alarm Control Panel Silent Knight 2 2 NP12-12 Battery 12 Volt, 12.0 Amp/Hr. Genesis 3 SLE-LTEV-FIRE Cellular Communicator Panel Starlink Fire 4 1 SK-PHOTO-W Addressable Photo-Electric Smoke Detector Silent Knight 5 1 B300-6 Detector Mounting Base, 6" Silent Knight 6 1 SK-Pull-SA Addressable Pull Station Silent Knight 7 2 SK-MINMON Addressable Mini Monitor Module Silent Knight 8 1 SSU00672 Fire Alarm System Document Box Spaceage Elect. 9 23 MHW Mini-Horn System Sensor 10 AIR 18/2 FPL Fire Cable Genesis Cable 11 AIR 14/2 FPL Fire Cable Genesis Cable Honeywell I Addressable Fire Alarm Control Panels n.!!ISilENT. ~KNIGHT 6700 Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor® (SK) sensors and 50 SK modules or 50 Hochiki(li) (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT® wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices. SWIFT is only compatible with System Sensor CSK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with N FPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single- point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable firmware • Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting • 6860 annunciator with a 4 x 40 large display • Four user- programmable buttons minimize time spent executing complex or routine tasks • Built-in USB interface for convenient and quick programming 6700 The 6700 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • JumpStart® auto programming reduces installation time • 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with N FPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4-to 7-digit operator's code. Page 2 of 4 -351607:B 9/26/2018 PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStartn) auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on-site access to current system programming. Programming can also be accomplished using the Windows®-based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows® software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft~-' Windows®. ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services • UL Listed: S2766 • CSFM 7165-0559:0501 • FDNY COA# 6250 ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED/ 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.silentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. ., SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (190°F), white SK-ISO: Fault isolator module SK-Ml NIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module 8300-6(-IV): 6" base for SK-W Series B210LP: 6" mounting base 8501(-BL,-IV,-WHITE): 4"flangeless base 8501: 4" Flangeless mounting base 8200S(-IV,-WH): Intelligent sounder base 8200S: Intelligent sounder base 8200S-LF(-IV,-WH): Low-Frequency intelligent sounder base 8200S-LF: Low-frequency intelligent sounder base B224RB(-IV,-WH): Relay base 8224RB: Relay base 82248I(-IV,-WH): Isolator base 822481: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-6IB: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SDSOS-6S8: Addressable 6" sounder base S0500-AIM: Addressable input module (switch input) S0500-ANM: Addressable notification module 5D500-ARM: Addressable relay module SDSOS-DTS-K: Remote test switch and LED indicator for the SD505-DUCTR S0505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SDSOS-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F (0°C-37°C). SDSOO-LIM: Addressable Line isolator module S0500-MIM: Addressable Mini input monitor module (switch input) S0505-PHOTO: Photoelectric smoke detector S0500-PS/-PSDA: Addressable Single or dual action pull station SDSOO-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRUCHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SO) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and 8510W 4· base WSK-HEAT: Wireless Heat, (135°F fixed temperature) and 8510W 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and 8510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput® circuits, and two Form C relays. Max. 16 per system. 5815RM K: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"0 COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL-MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm® receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm 0). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 -351607:B 9/26/2018 6700 Technical Specifications PHYSICAL Overall Dimensions: 12.71" W x 15.12" H x 3.33" D Weight: 15 lbs. Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (non- condensing) ELECTRICAL 6700 Primary AC: 120 VAC @ 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC power-limited Standby Current: 165mA Alarm Current: 310mA Battery Charging Capacity: 7 to 35AH Battery Size: 7AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Honeywell Silent Knight 12 Clintonville Road Northford, CT 064 72 800-328-0103 www.silentknight.com NOTIFICATION APPLIANCE CIRCUITS (NACs) Two programmable circuits which can be programmed individually as: NACs: 2.5A @ 27.4VDC per circuit, power-limited (with a panel maximum current of 2.5A) Auxiliary Power Circuits: 2.5A@ 27.4VDC per circuit, power-limited Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for the SLC WIRING: See the product manual for wiring details 351607 I B I 09/18 © 2018 Honeywell International Inc. Flexput~, Honeywell®, JumpStartt, Silent Knight®, SWIFT®, and System Sensorfl are registered trademarks of Honeywell International Inc. Hochiki® is a registered trademark of Hochiki Corporation. Microsoft® and Windows~ are registered trademarks of Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell rr!!I ILENT. ~I<NIGlIT LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST A TE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0559:0501 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Page 1 of 2 Silent Knight Model 6700, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model 6700 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED 1/0 Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network lnerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SCK Seismic Complaince Kit Primary Operating Power Supply: 120VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a commercial fire alarm control unit for use with separately listed initiating and This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2019 DA V/D CASTILLO, Program Coordinator Fire Engineering Division Listing Expires June 30, 2020 Listing No. 7165-0559:0501 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2019 DA V/D CASTILLO, Program Coordinator Fire Engineering Division Listing Expires June 30, 2020 • Universal full event sole & dual path cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere nationwide • Code-compliant, replaces 2 POTs lines per FACP saves thousands of dollars per year over the leased landlines • Supports 12V-24V control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels), as primary or backup • Full data Reporting to any Central Station nationwide, via choice of LTE Networks, Verizon® or AT&T®. Communicate critical life and safety alarm reports on LTE (Long Term Evolution) 10+ year life, cyber-protected multi-billion dollar cellular network, for maximum life safety & liability protection. • Proven to work even where other's won't-using Signal Boost™ & twin dual diversity antennas -Max. signal acquisition & null avoidance (receives signals simultaneously on both antennas) • Easiest installation, powered by panel, NO extra power supply, NO extra conduit. (Excludes Direct AC-Powered "-PS" models, with transformer option.) t • Dual Path Cellular/IP Models Save Time & Money -Uniquely including 4 programmable EOLR zone inputs; 2 Form C Relay outputs (no extra supervision modules to buy or install); plus, 2 Telephone- style jacks for easy FACP-connection. Self-supervised on 4 wires. • Preactivated to ensure communications -saves time and labor onsite • LED Status /Trouble Indicators 3 Radio Status LED Indicators (visible from outside standard model housing) -Green, Signal Strength; Amber-Busy/Activation; Red-Trouble (4 additional LEDs, not visible, for network status & troubleshooting). Power LED indicator viewable on outer metal enclosure models. • Over-the-Air Upgradable Communicator Firmware. Remote ability for critical/mandatory updates, without a truck-roll • Cost-saving models and plans for any code requirement. Dramatic savings over monthly dedicated landline charges. Code-compliant standard or metal models on choice of Verizon or AT&T L TE networks. UL and NFPA 72 Fire Code-Compliant, the Starlink Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest LTE coverage footprint, Verizon or AT&T, using proven Starlink circuitry, they are also available in locking metal models. All provide the most economical solution for easy, versatile installation. Also regional compliances, i.e., CSFM, NYCFD, LAFD and more. Easy, Universal Installation at Every Application; Panel- Powered Technology™. Starlink Fire Communications are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating between 12V and 24V. Flexible in any application, Starlink Fire also comes in standard, or models in metal housings, with code-compliant supervision, and choice of power options, Panel-Powered Technology™ (powered by the panel), or direct-connect 120VAC models. Signal Boost circuitry & dual diversity antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennae. Flexible Performance & Reporting Options. Starlink Fire provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes and requirements, with supervisory check-ins from 200 seconds, to 5 minutes; and/or from 1 to 6 hours. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www.napcocomnet.com. Napco Starlink Universal Fire Alarm Communicators • Sole Path Cellular and Dual Path Cellular &/or IP Models • Choice of LTE Networks, Verizon or AT&T models • Choice of plans (varies by model) -check-ins from 200 seconds to 5-minutes, and from 1 hour; up to 6 hours for dual path • Patented Signal Boost™and Dual Diversity Antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit for security professionals, on new or retrofit fire systems, i.e., tradeup missing/retired POTs lines, old radios & networks or new installations • Bonus: Full High-Speed Napco Panel remote uploading/ downloading • COMPLIANCES: NFPA 72 Editions: 2019, 2016, 2013, 2010, 2007; UL 864, 10th Ed., UL 1610, UL985, UL 1023, NYCFD; CSFM; LAFD connected by verizon✓ Ci.) NFPN Model Ordering & Specifications SOLi PATH SLE-LTEA-FIRE AT&T Yes SLE-LTEV-FIRE Verizon Yes DUAL PATH SLE-LTEAI-FIRE AT&T Yes SLE-LTEVI-FIRE Verizon Yes MODELS IN MUAL ENCLOSURE SOU PATH SLE-LTEA-CFB AT&T Yes SLE-LTEV-CFB Verizon Yes SLE-LTEA-CFB-PS AT&T Yes SLE-LTEV-CFB-PS Verizon Yes DUAL PATH SLE-LTEAI-CFB AT&T Yes SLE-LTEVI-CFB Verizon Yes SLE-LTEAI-CFBPS AT&T Yes SLE-LTEVI-CFBPS Verizon Yes ACCESSORIES: No No No No 2 TelCo jacks for EZ Yes Yes FACP Connect; 4 Programmable EOLR zone inputs; 2 Form C Yes Yes Relay outputs (avoids reqt for supervision 9 63 x 11 75 x 3 38" (HWD) No No No No No No No No 2 TelCo jacks for EZ Yes Yes FACP Connect; 4 Programmable EOLR zone inputs; 2 Form C Relay outputs (avoids Yes Yes reqt for supervision module) 2 Tel Co jacks for EZ Yes Yes FACP Connect; 4 Programmable EOLR zone inputs; 2 Form C Relay outputs (avoids Yes Yes reqt for supervision module) Panel-Powered Tech'y:tt Input Voltage/Input Current: 1 OV = 90mA; 12-25V= 71mA, 200mA peak during transmissions Panel-Powered Tech'y:tt Input Voltage: 10-25VDC: lnputCurrent: 162mA to 100mAstandby; 300mA peak during transmissions Panel-Powered Tech'y:tt Input Voltage/Input Current: 1 OV = 90mA; 12-2SV= 71mA, 200mA peak during transmissions Direct AC-Powered: Input Voltage: 120VAC nominal Input Current: 150mA max; maximum charging current: 200mA Panel-Powered Tech'y:tt Input Voltage:10-2SVDC: lnputCurrent: 162mA to 100mA standby; 300mA peak during transmissions DirectAC-Powered: Input Voltage: 120VAC nominal Input Current: 200mA max; maximum charging current: 200mA SLE-WIFI-MODULE Optionally connects supported dual path models to Internet via WiFi, eliminating Ethernet cable connection. Requires 7AH batt'y. (**See details Wl2191) SLE-ANTEXT75 Optional extended range omni. antenna w/ 75' cable, premium low-loss cable & full mounting hardware & ground fault isolation mounting plate SLE-ANTEXTS0 As above, with SO' cable SLE-ANTEXT30 As above, with 30' cable TRF12 Optional Plug in AC Transformer, 16.SV / 20VA (use is subject to local code compliance)t Free Commercial Fire LTE Tradeup Trifold Brochures I Mailers/Stujfers (A747) NaStarLf nk Fire 333 Bayview Ave., Amityville, NY 11701 • 1-800-645-9445 • www.napcosecurity.com IN1,IN2, IN3 IN1,IN2, IN3, IN4, INS IN1, IN2, IN3 IN1, IN2, IN3 IN1 , IN2, IN3, IN4, INS IN1, IN2, IN3, IN4, INS Input Ratings IN1: 9-25VDC Max input current 2mA IN2,IN3: 9-25VDC Max input current 1.2mA IN1: 9-2SVDC Max input current 2mA IN2,IN3,IN4,INS: 9-2SVDC Max input current 1.2mA IN1: 9-25VDC Max input current 2mA IN2,IN3: 9-2SVDC Max input current 1.2mA IN1 : 9-2SVDC Max input current 2mA IN2,IN3: 9-2SVDC Max input current 1.2mA IN1 : 9-2SVDC Max input current 2mA IN2,IN3,IN4,INS: 9-2SVDC Max input current 1.2mA IN1 : 9-2SVDC Max input current 2mA IN2,IN3,IN4,INS: 9-2SVDC Max input current 1.2mA PGM1, PGM2, PGM3 OUT1, OUT2, PGM3 PGM1, PGM2, PGM3 PGM1, PGM2, PGM3 OUT1 , OUT2, PGM3 OUT1 , OUT2, PGM3 ~AT&T ~ connectea oy verizon✓ Output Ratings Open Collector Outputs Max 3V when active, Max 2SV when not active. Max current 24mA@25V OUT1 ,OUT2:Dry Contact, Form C Relay, 30V AC/DC, SOOmA Max PGM3: Open Collector Outputs Max 3V when active, Max 2SV when active. Max current 24mA@ 2SV Open Collector Outputs Max 3V when active, Max 25V when not active. Max current 24mA@2SV Open Collector Outputs Max 3V when active, Max 2SV when not active. Maximum current 24mA@2SV OUT1 ,OUT2:Dry Contact, Form C Relay, 30V AC/DC, SOOmA Max PGM3: Open Collector Outputs Max 3Vwhen active, Max 2SV when active. Max current 24mA@ 2SV OUT1,0UT2:Dry Contact, Form C Relay, 30V AC/DC, SOOmA Max PGM3: Open Collector Outputs Max 3Vwhen active, Max 2SV when active. Max current 24mA@ 2SV Transformer (TRF12 16VAC, 20VA transformer) Transformer (TRF12 16VAC, 20VA transformer) Fi relink™ Integrated Fire Alarm Control Panel w/ Starlink Fire L TE Built In 10· FL-32FACP-L TEV Firewolf 8 Zone 24V Conventional Commercial Fire Alarm Control Panel with onboard Starlink Fire® Sole Path, Verizon L TE Cellular Alarm Communicator and integral menu-driven LCD annunciator, w/ 4amp, 24V power supply. Optionally expandable up to 32 points/zones via commercial addressable, wireless or conventional fire devices (2 onboard NACs providing up to 4A notification power). Locking, metal red enclosure,(surface or flush mount*) removable 16"x17" door w/14.25"x16" base. Houses 16Ah battery backup. Note: Nways consult technical manual and/or AHJ for compliance requirements for your area/appllication. Starlink, Starlink Fire, Firelink, Signal Boost, Panel-Powered Technology, Gemini & Gemini Commercial are trademarks of Napco. AT&T, Verizon, LTE, etc. are trademarks of their respective companies. *Starlink offers full data coverage in US from virtually all panel brands reporting in Contact ID or 4/2. tt For Panel-Powered technology, regulated auxiliary power outputs are required on Listed FACP. ** Add 40mA to input current & Standby Battery requirement. tWhere permitted by AHJ; requires conduit.. For full details on the Starlink tradeup incentive see online under http://www.napcosecurity.com/starlink/starlink4gupgrade/ tPromo subject to change w/o prior notice. LTE lifespan claims are based on those of carriers. ©NAPCO, NAPCO Security Technologies Inc. (NASDAQ:NSSC) A734A 2019.8 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0992:0144 Page 1 of 2 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Napco333 Bayview Avene, Amityville, NY 11701 Contact: David Wagner (631) 842-9400 Fax (631) 842-2726 Email: dwagner@napcosecurity.com Models SLE3/4G-CB, SLE3/4G-CB-TF, SLE3/4G-CFB, SLE3/4G-CFB-PS, SLE-CDMA, SLE-CDMA-FIRE, SLE-GSM-3/4G, SLE-GSM-FIRE, SLECDMA-CB, SLECDMA-CB-TF, SLECDMA-CFB, SLECDMA-CFB-PS, SLE-L TEV-FIRE, SLE-L TEV-8D, SLE-L TEV, SLE-L TEV-CFB-PS, SLE-L TEV-CB-TF, SLE-L TEV-CFB, SLE-L TEV-CB, SLE-L TEA-CFB, SLE-L TEA-CFB-PS and SLE-L TEA-FIRE Sole Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. Models SLECDMAI-CFB-PS, SLE3/4GI-CFB-PS, SLECDMAI-CB-TF, SLE3/4GI-CB-TF, SLECDMAI-CFB, SLE3/4GI-CFB, SLECDMAI-CB, SLE3/4GI-CB, SLE-GSMl-3/4G, SLE-CDMAI, SLE-GSMI-FIRE, SLE-CDMAI-FIRE, SLE-L TEVI-CFBPS, SLE-L TEVI-CFB, SLE-L TEVI-FIRE, *SLE-L TEAI-CFBPS, *SLE-L TEAI-CFB and *SLE-L TEAi-FiRE. Dual Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. Refer to listee's data sheet for additional detailed product description and operational considerations. 120 Vac -SLE3/4G-CB, SLE3/4GI-CB-TF, SLE3/4G-CFB-PS, SLE3/4GI-CFB-PS, SLECDMA-CFB-PS, SLECDMAI-CFB-PS, SLECDMA-CB-TF, SLECDMAI-CB-TF, SLE-L TEV-CFB-PS, SLE-L TEV-CB-TF, SLE-L TEVI-CFBPS, SLE-L TEA-CFB-PS, *SLE-L TEAI-CFBPS 10-15 Vdc-SLECDMAI-CB, SLE3/4GI-CB, SLE-GSMl-3/4G, SLE-CDMAI, SLE-LTEV, SLE-L TEV-8D, SLE-L TEV-CB 10-25 Vdc-SLECDMAI-CFB, SLE3/4GI-CFB, SLE-GSMI-FIRE, SLE-CDMAI-FIRE, SLE-L TEV-FIRE, SLE-L TEV-CFB, SLE-L TEVI-FIRE, SLE-L TEA-CFB, SLE-L TEA-FIRE, *SLE-L TEAi-FiRE, *SLE-L TEAI-CFB, SLE-L TEVI-CFB 11-15 Vdc-SLE3/4G-CB, SLE-CDMA, SLE-GSM-3/4G, SLECDMA-CB 11-25 Vdc-SLE3/4G-CFB, SLECDMA-CFB, SLE-CDMA-FIRE, SLE-GSM-FIRE *Rev 09-23-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 INSTALLATION: MARKING: APPROVAL: Listing No. 7300-0992:0144 Page 2 of 2 In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev 09-23-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 Honeywell ~SILENT. ~KNIGHT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DN R Series duct detector housings. FEATURES & BENEFITS • New modern profile for improved aesthetics • Stable communication technique with noise immunity • Low standby current • Two-wire SLC connection • Optional remote, single-gang LED accessory • Dual LED design provides 360° viewing angle • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Built-in tamper- resistant feature • Sealed against back pressure • Expanded color options • SEMS screws for wiring of the separate base SK-PHOTO-W • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of installation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with N FPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to N FPA 72. System Smoke Detector Application Guide, document A0S-1003, is available at systemsensor.com INSTALLATION The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. • When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector, white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with ON R(W) duct smoke detectors, white. SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES 8300-6: White, standard flanged low-profile mounting base. 8300-6-BP: Bulk pack of 8300-6, package contains 10. 8300-6-IV: Ivory, standard flanged low-profile mounting base. 8501-WHITE: White, standard European flangeless mounting base.UL listed. 8501-BL: Black, standard European flangeless mounting base. UL listed. 8501-IV: Ivory, standard European flangeless mounting base. UL listed. 8200S-WH: White, Intelligent, programmable sounder base. 8200S-IV: Ivory, Intelligent, programmable sounder base. 8200SR-WH: White, Intelligent sounder base for retrofit applications. 8200SR-IV: Ivory, Intelligent sounder base for retrofit applications. 8200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. 8200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. 8200S R-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. 8200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. 8224RB-IV: Ivory, plug-in System Sensor relay base. 822481-WH: White, plug-in System Sensor isolator detector base. 82248I-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RAl00Z: Remote LED annunciator SMBG00: Surface Mounting Kit (flanged). TR300: Replacement trim ring for 8300-6, white. TR300-IV: Replacement trim ring for 8300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B300-6 base Diameter: 6.2" (156mm) installed in B300-6 base 4.1" (104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 32°F to 122°F (0°C to 50°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) UL listed Velocity range: Photo/Photo with Thermal: 0 to 4,000 fpm CO to 20 m/sec) (suitable for installation in ducts) Humidity: 10% to 93% non-condensing Thermal Ratings: Fixed Temperature Set point: 135°F (57°C) ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Operating Current@ 24VDC: 200µA (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford. CT06472 800-328-0103 COMPATIBILITY The SK-PHOTO-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S6173 FM approved CSFM: 7272-0559:0523 Doc 351634 I Rev A I 04/18 © 2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft. Windows. and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®. System Sensor® and Honeywell~' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support. call 800-446-6444. Honeywell rr?!SILENT ~KNIGHT LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-0559:0512 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Page 1 of 1 Models IDP-PHOTO-W, IDP-PHOTO-R-W, IDP-PHOTO-T-W, SK-PHOTO-W, SK-PHOTO-R-W, and SK-PHOTO-T-W analog addressable, photoelectric smoke detectors for open area and duct installations. Models IDP-PHOTO-T-W and SK-PHOTO-T-W have complementary heat detectors. All models are similar except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. 24 voe. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models *B224BI and B224RB (CSFM Listing 7300-1653:0126), *B501, *B210LP (CSFM Listing 7300-1653:0109), B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition, January 11, 2016. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. 7272-0028:0503 *Revision 12-17-19 \/WW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 Honeywell a~~ SK-PULL-SA/ SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. FEATURES & BENEFITS • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets ADA requirement for 5 Lbs maximum pull force to active • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Shell, door, and handle molded from durable LEXAN- SK-PULL-SA SK-PULL-DA • Reliable analog communications for trouble-free operation • Braille text on station handle • Rotary address switches for fast installation • Handle Latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • MEA Listed SK-PULL-SA/ SK-PULL-DA Technical Specifications PHYSICAL Dimensions: 5.5" H x 4" W x 1.45" D (14 x 10.2 x 3.7cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Ala rm Switch: Single pole, single throw (SPST) normally open (N/0) switch which closes upon activation of the pull station ELECTRICAL Operating Voltage: 15 -32VDC SLC Standby and Alarm Current: 350µA Wire Gauge: Up to 12AWG (3.1 mm2) ENVIRONMENTAL Operating Temperature: 32°F -120°F (0°C - 49°C) Humidity: 10% -93% non-condensing For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT06472 800-328-0103 ORDERING INFORMATION SK-Pull-SA: Single Action Pull Station SK-Pull-DA: Dual Action Pull Station ACCESSORIES BG-TR: Optional trim ring. SB-1/O: Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to SK-Pull-SA and SK-Pull-DA COMPATIBILITY The SK-PULL-SA AND SK-PULL-DA are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system Doc3501351RevEl11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight'!!, System Sensor® and Honeywell'~' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell ~SILENT. a..llI<NIGHf LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-0559:0161 Page 1 of 1 7150 --FIRE ALARM PULL BOXES SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. 7150-0028:0199 04-16-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 Honeywell ~SILENT. ~KNIGHf SK-MINI MON Intelligent Mini Monitor Module The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels (FACPs). The SK- MINIMON acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-MINIMON supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. INSTALLATION The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. FEATURES & BENEFITS • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL Listed • CSFM Listed • FM Approved SK-MINIMON SK-Ml NIMON Technical Specifications PHYSICAL Dimensions: 2.75~ W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) ELECTRICAL Operating Voltage: 15 -32VDC SLC Standby and Alarm Current: 350 µA End-of-Line Resistance: 47Kn Initiating device circuit wiring resistance: 1,5000 max SLC loop resist ance: 400 max Wire Length: 6" min. ENVIRONMENTAL Operating Temperature: 32°F -120°F (0°C - 49°C) Humidity: 10% -93% non-condensing For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT06472 800-328-0103 ORDERING INFORMATION SK-MINIMON: Mini monitoring module COMPATIBILITY The SK-MINIMON is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Ad dressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Ad dressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system Doc 350133 I Rev G 111/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell~ are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800 -446-6444. Honeywell f;?!SILENT' ~KNIGHT LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0559:0155 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Page 1 of 1 Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, !DP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, !DP-Control, !DP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules.and *IDP-RELAYMON-2, *SK-RE LA YMON-2 with 2 inpuU2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. 16-33 VDC Primary In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 ~SYSTEM '-~ SENSOR® Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • Listing for ceiling or wall mounting Agency Listings ®<e> LISTED APPROVED S4011 3028007 CS1099 7135-1653:196 SPECT~rf A.&XA"alJi •. l The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions Weight Operating Temperature Range Mounting Electrical Specifications Input Terminals Nominal Voltage Operating Voltage Operating Voltage with MDL 4.6'L x 2.9W x .45'D 2.67 oz. 32°F to 120°F (0°C to 49°C) Surface: deep single-gang back box (2¾,, deep) Flush: Standard 4" x 4" back box with single gang mud ring, which allows sufficient clearance for conduit entrance. 12 to 18 AWG Regulated 12DC/FWR or regulated 24DC/FWR 8-33 9-33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8-17.SVDC 8-17.SVFWR Nominal Temporal High 2 Temporal Low 3 Non-High temporal 4 Non-Low temporal Sounder Current Draw (mA RMS) Switch Position Sound Pattern 1 Temporal 2 Temporal 3 Non-temporal 4 Non-temporal Ordering Information Part No. Description MHR Mini-Horn, Red MHW Mini-Horn, White ~SYSTEM '-~ SENSOR® VDC 68 67 71 66 65 69 72 71 75 70 69 73 8-17.5 Volts Volume DC FWR High 12 10 Low 10 9 High 22 17 Low 17 13 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 12 Nominal 12 16--33 16--33 VFWR VDC VFWR 70 78 76 68 76 75 74 80 79 72 78 77 16--33 Volts DC FWR 17 15 14 13 29 25 21 19 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01500 • 3/12 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST A TE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-1653:0196 Page 1 of 1 7135 --AUDIBLE DEVICES System Sensor, Unincorporated Div of Honeywell lnt'I lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Models MHR, MHW and APA151 horns. The Model APA151 is a remote sounder intended to be connected to the alarm indicating circuit of listed duct smoke detectors. All units are for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. Electrical: APA 151: Regulated 24 VDC Operational 16-33 Volts, 30mA MHR and MHW: Regulated 12V DC/FWR and 24V DC/FWR Operational 8-17.5 and 16-33 Volts, 18mA at 12Vand 30mA at 24V Audibility: MHR and MHW Tones 1, 2, 3 & 4 are Public Mode at 24V DC/FWR Tone 3 is Public Mode at 12V DC Tones 1, 2 & 4 are Private Mode at 12 V DC Tones 1, 2, 3 & 4 are Private Mode at 12V FWR In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Models MHR and MHW are listed as an audible signal appliance for use with separately listed compatible fire alarm control units. Model APA 151 is listed as an accessory horn for use with separately listed 4-wire conventional duct smoke detectors. (REF: 3240-1653:119) Refer to manufacturer's Installation Manual for details. 03-15-07 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert NIA in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: March 18, 2022 Supplemental Pages Attached: Alarm Signals to CS 1. PROPERTY INFORMATION Nameofproperty: _S_e_a_G_la_s_s_H_o_m_es _______________________________ _ Address: 2646 State Street Description of property: Eight attached privately owned residential units. Name of property representative: Rod Boone, Prophet Solutions, Inc. Address: 814 S. El Camino Real Phone: 858-334-9490 Fax: E-mail: rod@prophetsolutionsinc.com 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Fire Etc. ------------------------------------- Address: 2190 Main Street, San Diego, CA 92113 Phone: 760-67 4-5914 Fax: E-mail: Service organization: Alarms of San Diego Address: PO Box 143, Hemet, CA 92546 Phone: 760-747-4232 Fax: E-mail: alarmsofsandiego@gmail.com Testing organization: _S_a_m_e_a_s_A_b_o_v_e ______________________________ _ Address: Phone: Fax: E-mail: Effective date for test and inspection contract: March 18, 2022 Monitoring organization: National Monitoring Center Address: 25341 Commercentre Drive, Lake Forest, CA 92630 Phone: 800-662-1711 Fax: 800-662-1513 E-mail: Account number: A 1 -7184 Phone line 1: NIA Phone line 2: N/A ---------- Means of transmission: Cellular Entity to which alarms are retransmitted: N/A Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: _A_t _F_ire_P_a_n_el _____________ _ 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: 181 New system D Modification to existing system Permit number: NFPA 72 edition: 2016 ------- 4.1 Control Unit Manufacturer: _S_ile_n_t_K_n_ig ___ h_t _______________ _ Model number: 6700 4.2 Software and Firmware Firmware revision number: 3.4.1 .2707 4.3 Alarm Verification 181 This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright© 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. p. 1 of 3) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power SYSTEM RECORD OF COMPLETION (continued) Input voltage of control panel: _1_2_0v_a_c ____________ _ Control panel amps: _1_.5 _______ _ Overcurrent protection: Type: _B_re_a_k_e_r ___________ _ Amps: _20 ___________ _ Branch circuit disconnecting means location: Breaker Panel SDG&E Rm 5.1.2 Secondary Power Type of secondary power: 24vdc Location, if remote from the plant: Calculated capacity of secondary power to drive the system: Number: 6 In standby mode (hours): _24 _____________ _ In alarm mode (minutes): 5.2 Control Unit 181 This system does not have power extender panels D Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Signaling Line SLC 4 Device Power SLC 4 Initiating Device SLC 4 Notification Appliance Style Y B Other (specify): 7. REMOTE ANNUNCIATORS Type Location 8. INITIATING DEVICES Addressable or Type Quantity Conventional Alarm or Supervisory Manual Pull Stations 1 Addressable Alarm Smoke Detectors 1 Addressable Alarm Duct Smoke Detectors Heat Detectors Gas Detectors Waterflow Switches 1 Addressability Alarm Tamper Switches 2 Addressable Supervisory 5 Survivability Level 1 1 1 1 Sensing Technology Pull Photo Electric Mechanical Mechanical Copyright© 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p 2 ot 3) SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible 23 Mini Horns Visible Combination Audible and Visible 10. SYSTEM CONTROL FUNCTIONS Type Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS 181 This system does not have interconnected systems. D Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor been installed according to all NFP A standards cited herein. Printed name: Francho Davis Title: President 12.2 System Operational Test ed according to all NFP A standards cited herein. Signed: Printed name: Tony Gonzalez Organization: _F_ire_E_tc_. ________ _ Title: Installer 12.3 Acceptance Test Quantity Date: 3/18/2022 Phone: 619-654-7063 Date: 3/18/2022 Phone: 619-654-7063 Date and time of acceptance test: _3/_1_8_/2_0_2_2 __________________________ _ Installing contractor representative: _T_o_n_..y_G_o_n_z_a_le_z ________________________ _ Testing contractor representative: _T_on .... y __ G_on_z_a_le_z _________________________ _ Property representative: _R_o_d_B_o_o_ne ______________________________ _ AHJ representative: Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. , p 3 of 3)