Loading...
HomeMy WebLinkAbout1911 PALOMAR OAKS WAY; ; FPC2021-0145; PermitPERMIT REPORT Fire Permit Print Date: 06/16/2022 Job Address: 1911 PALOMAR OAKS WAY, CARLSBAD, CA 92008-6511 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel#: 2120910800 Track#: Valuation: $66,974.40 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: DRAMM ECHTER FARMS -MEZZANINE SPRINKLER Tl (17 HEADS) Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION INC KELLY SANTOS 9925 PROSPECT AVE, # STE B SANTEE, CA 92071-4376-SAN DIEGO (619) 562.:.3010 FEE FIRE NFPA 13 or 13R System 7-100 heads Total Fees: $553.00 Fire Department Total Payments To Date: $553.00 (city of Carlsbad Permit No: FPC2021-0145 Status: Closed -Finaled Applied: 08/06/2021 Issued: 08/17/2021 Finaled Close Out: 06/16/2022 Final Inspection: INSPECTOR: Salcedo, Felix FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION INC 9925 PROSPECT AVE, # STE B SANTEE, CA 92071 (619) 562-3010 Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-73 14 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov Job Name Building Location System Contract Data File . __ Fire Protection by Computer Design AMERICAN AUTOMATIC FIRE 9925 PROSPECT AVE. SUITE B SANTEE, CA 92071 D.E. FARMS MEZZANINE 1911 PALOMAR OAKS WAY CARLSBAD, CA DE Farms-Calculations. WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 AMERICAN AUTOMATIC FIRE D.E. FARMS Hydraulic Design Information Sheet Name -D.E. FARMS Date -8 .4 .21 System No . - Location -1911 PALOMAR OAKS WAY CARLSBAD, CA Building -MEZZANINE Contractor -Contract No. - Drawing No. -Calculated By - Construction: (X) Combustible ( ) Non-Combustible Occupancy -STORAGE Ceiling Height -11 '-0" s y s T E M D E s I G N ( ) NFPA 13 ( ) NFPA 231 Other Lt. Haz. NFPA 231C Ord.Raz .Gp . ( ) 1 (X) 2 ( ) 3 ( ) Ex .Raz. ( ) Figure Curve Specific Ruling Area of Sprinkler Operation -1500 Density -.20 Area Per Sprinkler -120 Elevation at Highest Outlet -25.8 Hose Allowance -Inside Rack Sprinkler Allowance Hose Allowance -Outside -250 Note Made By System Type (X) Wet ( ) Dry ( ) Deluge ( ) Preaction ( ) Other Date Sprinkler/Nozzle Make TYCO Model TY313 Size 1/2" K-Factor 5.6 Temp.Rat .200 Calculation Summary Flow Required -347.7 C-Factor Used: 120 Press Required -42 .6 Overhead 140 BOR Underground w A T E R s u p p L y C 0 M M s R T A 0 C R K A G E Water Flow Test: Date of Test -4.30 .21 Time of Test Static Press -60.3 Residual Press -54 Flow -1570 Elevation Location - Pump Data : Rated Cap .- @ Press Elev. Tank or Reservoir: Cap . - Elev .- Well Proof Flow Source of Information -CARLSBAD FIRE DEPT Commodity Storage Ht. Storage Method: Single Row Double Row Mult. Row Flue Spacing Longitudinal Solid Piled Class Area % Conven. Pallet Slave Pallet Horizontal Barriers Provided : Location Aisle W. Palletized g. 0 ( ) Auto. Storage ( ) Solid Shelf ( ) Open Shelf Rack Encap. Non Clearance:Storage to Ceiling Transverse Computer Programs by Hydratec Inc. Revision: 50.52.1 Page Date 1 8.4.21 Water Supply Curve C AMERICAN AUTOMATIC FIRE D.E. FARMS City Water Supply: C 1 -Static Pressure . 60. 3 C2 -Residual Pressure: 54 C2 -Residual Flow 1570 150 140 130 p 120 R 110 E 100 s 90 s 80 U 70 C1 R 60 I 02 E 50 40 03 30 20 10 200 400 600 800 ,-i::l -e 1000 1200 1400 1600 FLOW ( N A 1.85 ) Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 2 Date 8.4.21 Demand: D1 -Elevation : 6.063 02 -System Flow D2 -System Pressure Hose ( Demand ) : 347.708 : 52.559 : 250 03 -System Demand Safety Margin 1800 : 597.708 : 6.685 Fittings Used Summary AMERICAN AUTOMATIC FIRE D.E. FARMS Fitting Legend Abbrev. Name E NFPA 13 90' Standard Elbow I 90' Grvd-Vic Elbow #10 J 90'T ee-Branch Grv Vic #20 T NFPA 13 90' Flow thru Tee Zwd Watts 709DCDA Unit Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 2 2 3 4 5 0 0 2 3 4 3.5 0 0 4.5 6 8 8.5 3 4 5 6 8 10 Fitting generates a Fixed Loss Based on Flow Inches Feet US Gallons per Minute Pounds per Square Inch 2½ 3 6 7 6 5 10.8 13 12 15 Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors 3½ 8 8 17 17 of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a* will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 10 12 14 7 8.5 10 16 21 25 20 25 30 Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 3 Date 8.4.21 8 10 12 14 16 18 20 24 18 22 27 35 40 45 50 61 13 17 20 23 25 33 36 40 33 41 50 65 78 88 98 120 35 50 60 71 81 91 101 121 Pressure/ Flow Summary-STANDARD AMERICAN AUTOMATIC FIRE Page 4 D.E. FARMS Date 8.4.21 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. 1 11.0 5.6 18.37 na 24.0 0.2 120 7.0 2 11.0 18.45 na 3 11.0 5.6 18.46 na 24.06 0.2 120 7.0 4 11.0 5.6 18.62 na 24.17 0.2 120 7.0 5 11.0 5.6 18.98 na 24.4 0.2 120 7.0 6 11.0 5.6 19.63 na 24.81 0.2 120 7.0 7 11.0 5.6 20.63 na 25.43 0.2 120 7.0 8 11.0 5.6 22.08 na 26.31 0.2 120 7.0 9 11.0 5.6 18.38 na 24.01 0.2 120 7.0 10 11.0 18.45 na 11 11.0 5.6 18.5 na 24.09 0.2 120 7.0 12 11.0 5.6 18.74 na 24.24 0.2 120 7.0 13 11.0 5.6 19.22 na 24.55 0.2 120 7.0 14 11.0 5.6 20.02 na 25.05 0.2 120 7.0 15 11.0 5.6 21.21 na 25.79 0.2 120 7.0 16 11.0 5.6 22.9 na 26.8 0.2 120 7.0 17 11.0 25.67 na 18 11.0 27.03 na 19 25.8 22.82 na 21 25.8 25.97 na 22 25.8 28.78 na 24 25.8 26.02 na 25 25.8 28.88 na 27 25.8 26.06 na 28 25.8 29.25 na 30 25.8 30.82 na 31 25.8 30.21 na 33 25.8 30.83 na 34 25.8 30.57 na 36 25.8 30.63 na 38 25.8 30.84 na 39 25.8 30.71 na 40 25.8 30.71 na 42 25.8 30.87 na 43 25.8 30.76 na 44 25.8 30.78 na 47 25.8 30.91 na 48 25.8 30.85 na 50 25.8 30.96 na 51 25.8 30.91 na 53 25.8 31.01 na 54 25.8 30.96 na 56 25.8 31.07 na 57 25.8 31.0 na 59 25.8 31.13 na 60 25.8 31.13 na 62 25.8 31.2 na 63 25.8 31.17 na 65 25.8 31.27 na 66 25.8 31.23 na 68 25.8 31.35 na 69 25.8 31.28 na 37 25.8 30.92 na 41 25.8 30.92 na 45 25.8 30.92 na 49 25.8 30.93 na 52 25.8 30.95 na 55 25.8 30.96 na 58 25.8 30.98 na 61 25.8 30.99 na 64 25.8 31.0 na 67 25.8 31.01 na Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary -Standard AMERICAN AUTOMATIC FIRE Page 5 D.E. FARMS Date 8.4.21 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. 23 25.8 30.18 na 26 25.8 30.19 na 29 25.8 30.24 na 32 25.8 30.34 na 35 25.8 30.61 na 46 25.8 30.81 na 20 25.8 25.94 na TOR 25.8 31.78 na BOR 1.0 42.55 na UG1 -3.0 44.31 na UG2 -3.0 44.35 na BF1 3.0 41.78 na BF2 3.0 49.87 na UG3 -3.0 52.5 na SRC -3.0 52.56 na 250.0 The maximum velocity is 15.81 and it.occurs in the pipe between nodes 16 and 17 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations -Hazen-Williams -2007 AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 1 to 2 2 to 3 3 to 4 4 to 5 5 to 6 6 to 7 7 to 8 8 to 17 2 to 10 9 to 10 10 to 11 11 to 12 12 to 13 13 to 14 14 to 15 Qa Qt 24.00 24.0 -5.52 18.48 24.06 42.54 24.17 66.71 24.40 91.11 24.81 115.92 25.43 141.35 26.31 167.66 0.0 167.66 5.52 5.52 0.0 5.52 24.01 24.01 5.52 29.53 24.08 53.61 24.24 77.85 24.55 102.4 25.06 127.46 Dia. "C" Pf/Ft 2.157 120.0 0.0055 2.157 120.0 0.0033 2.157 120.0 0.0157 2.157 120.0 0.0361 2.157 120.0 0.0643 2.157 120.0 0.1003 2.157 120.0 0.1448 2.157 120.0 0.1986 2.157 120.0 0.0004 2.157 120.0 0.0055 2.157 120.0 0.0080 2.157 120.0 0.0241 2.157 120.0 0.0480 2.157 120.0 0.0798 2.157 120.0 0.1196 Fitting or Eqv. Ln. J 10.461 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.307 0.0 0.0 J 10.461 0.0 0.0 J 10.461 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Pipe Ftng's Total 4.100 10.461 14.561 5.400 0.0 5.400 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 13.800 4.307 18.107 12.000 10.461 22.461 4.100 10.461 14.561 5.400 0.0 5.400 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 Computer Programs by Hydratec Inc. Pt Pe Pf 18.367 0.0 0.080 18.447 0.0 0.018 18.465 0.0 0.157 18.622 0.0 0.361 18.983 0.0 0.643 19.626 0.0 1.003 20.629 0.0 1.448 22.077 0.0 3.596 25.673 18.447 0.0 0.008 18.455 18.375 0.0 0.080 18.455 0.0 0.043 18.498 0.0 0.241 18.739 0.0 0.480 19.219 0.0 0.798 20.017 0.0 1.196 Pt Pv Pn Revision: 50.52.1 Page 6 Date 8.4.21 ******* Notes ****** K Factor= 5.60 Vel= 2.11 Vel= 1.62 K Factor= 5.60 Vel = 3.73 K Factor= 5.60 Vel= 5.86 K Factor= 5.60 Vel= 8.00 K Factor= 5.60 Vel = 10.18 K Factor= 5.60 Vel = 12.41 K Factor= 5.60 Vel = 14.72 K Factor= 33.09 Vel = 0.48 K Factor= 1.28 K Factor= 5.60 Vel= 2.11 Vel= 2.59 K Factor= 5.60 Vel = 4.71 K Factor= 5.60 Vel= 6.84 K Factor= 5.60 Vel= 8.99 K Factor= 5.60 Vel = 11.19 Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 15 to 16 16 to 17 17 to 18 18 to 19 19 to 20 21 to 22 22 to 23 24 to 25 25 to 26 27 to 28 28 to 29 30 to 31 31 to 32 Qa Qt 25.79 153.25 26.80 180.05 167.66 347.71 0.0 347.71 0.0 347.71 0.0 347.71 112.91 112.91 -50.69 62.22 0.0 62.22 113.96 113.96 -53.79 60.17 0.0 60.17 120.84 120.84 -69.24 51.6 a.a 51.60 -49.32 -49.32 66.15 16.83 Dia. "C" Pf/Ft 2.157 120.0 0.1682 2.157 120.0 0.2266 3.26 120.0 0.1025 3.26 120.0 0.1025 3.26 120.0 0.1025 2.157 120.0 0.0956 2.157 120.0 0.0317 2.157 120.0 0.0972 2.157 120.0 0.0298 2.157 120.0 0.1083 2.157 120.0 0.0224 2.157 120.0 -0.0207 2.157 120.0 0.0028 Fitting or Eqv. Ln. a.a a.a a.a J 10.461 a.a a.a 6.72 a.a 0.0 6.72 0.0 0.0 T 20.159 0.0 0.0 T 12.307 0.0 a.a T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 Pipe Ftng's Total 10.000 a.a 10.000 1.800 10.461 12.261 6.500 6.720 13.220 14.800 6.720 21.520 10.300 20.159 30.459 17.100 12.307 29.407 31.900 12.307 44.207 17.100 12.307 29.407 31.900 12.307 44.207 17.100 12.307 29.407 31.900 12.307 44.207 17.100 12.307 29.407 31.900 12.307 44.207 Pt Pe Pf 21.213 a.a 1.682 22.895 a.a 2.778 25.673 0.0 1.355 27.028 -6.410 2.205 22.823 0.0 3.121 25.944 25.966 0.0 2.811 28.777 0.0 1.403 30.180 26.016 0.0 2.859 28.875 0.0 1.319 30.194 26.064 0.0 3.186 29.250 0.0 0.992 30.242 30.818 0.0 -0.608 30.210 0.0 0.125 Pt Pv Pn Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 7 Date 8.4.21 ******* Notes ****** K Factor= 5.60 Vel = 13.46 K Factor= 5.60 Vel = 15.81 Vel = 13.37 Vel = 13.37 Vel = 13.37 K Factor= 68.27 Vel= 9.91 Vel = 5.46 K Factor= 11.33 Vel = 10.01 Vel= 5.28 K Factor= 10.95 Vel = 10.61 Vel= 4.53 K Factor= 9.38 Vel= 4.33 Vel= 1.48 Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 33 to 34 34 to 36 36 to 37 38 to 39 39 to 40 40 to 41 42 to 43 43 to 44 44 to 45 47 to 48 48 to 49 50 to 51 51 to 52 Qa Qt 0.0 16.83 -30.71 -30.71 41.66 10.95 10.79 21.74 0.0 21.74 -22.13 -22.13 25.24 3.11 15.09 18.2 0.0 18.20 -19.79 -19.79 26.21 6.42 8.44 14.86 0.0 14.86 -9.58 -9.58 20.56 10.98 0.0 10.98 -8.42 -8.42 15.40 6.98 Dia. "C" Pf/Ft 2.157 120.0 -0.0086 2.157 120.0 0.0013 2.157 120.0 0.0046 2.157 120.0 -0.0047 2.157 120.0 0.0001 2.157 120.0 0.0033 2.157 120.0 -0.0038 2.157 120.0 0.0005 2.157 120.0 0.0022 2.157 120.0 -0.0010 2.157 120.0 0.0013 2.157 120.0 -0.0008 2.157 120.0 0.0006 Fitting or Eqv. Ln. T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 Pipe Ftng's Total 17.100 12.307 29.407 31.900 12.307 44.207 51.200 12.307 63.507 17.100 12.307 29.407 31.900 12.307 44.207 51.200 12.307 63.507 17.100 12.307 29.407 31.900 12.307 44.207 51.200 12.307 63.507 49.000 12.307 61.307 51.200 12.307 63.507 49.000 12.307 61.307 51.200 12.307 63.507 Computer Programs by Hydratec Inc. Pt Pe Pf 30.335 30.826 0.0 -0.253 30.573 0.0 0.056 30.629 0.0 0.289 30.918 30.844 0.0 -0.138 30.706 0.0 0.006 30.712 0.0 0.207 30.919 30.873 0.0 -0.112 30.761 0.0 0.021 30.782 0.0 0.142 30.924 30.913 0.0 -0.061 30.852 0.0 0.081 30.933 30.959 0.0 -0.048 30.911 0.0 0.035 Pt Pv Pn Revision: 50.52.1 Page 8 Date 8.4.21 ******* Notes ****** K Factor= 3.06 Vel= 2.70 Vel = 0.96 Vel= 1.91 K Factor= 3.91 Vel= 1.94 Vel= 0.27 Vel= 1.60 K Factor= 3.27 Vel= 1.74 Vel= 0.56 Vel= 1.30 K Factor= 2.67 Vel= 0.84 Vel = 0.96 K Factor= 1.97 Vel= 0.74 Vel= 0.61 Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 53 to 54 54 to 55 56 to 57 57 to 58 59 to 60 60 to 61 62 to 63 63 to 64 65 to 66 66 to 67 68 to 69 69 to 70 Qa Qt 0.0 6.98 -8.74 -8.74 10.33 1.59 0.0 1.59 -10.12 -10.12 4.52 -5.6 0.0 -5.60 -2.95 -2.95 -11.07 -14.02 0.0 -14.02 -6.54 -6.54 -9.41 -15.95 0.0 -15.95 -8.80 -8.8 -9.38 -18.18 0.0 -18.18 -10.69 -10.69 -9.92 -20.61 Dia. "C" Pf/Ft 2.157 120.0 -0.0008 2.157 120.0 0.0 2.157 120.0 -0.0011 2.157 120.0 -0.0004 2.157 120.0 -0.0001 2.157 120.0 -0.0020 2.157 120.0 -0.0005 2.157 120.0 -0.0025 2.157 120.0 -0.0008 2.157 120.0 -0.0033 2.157 120.0 -0.0012 2.157 120.0 -0.0041 Fitting or Eqv. Ln. T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 T 12.307 0.0 0.0 Pipe Ftng's Total 49.000 12.307 61.307 51.200 12.307 63.507 49.000 12.307 61.307 51.200 12.307 63.507 45.000 12.307 57.307 55.200 12.307 67.507 45.000 12.307 57.307 55.200 12.307 67.507 45.000 12.307 57.307 55.200 12.307 67.507 45.000 12.307 57.307 55.200 12.307 67.507 Pt Pe Pf 30.946 31.011 0.0 -0.052 30.959 0.0 0.003 30.962 31.069 0.0 -0.068 31.001 0.0 -0.023 30.978 31.134 0.0 -0.006 31.128 0.0 -0.136 30.992 31.202 0.0 -0.029 31.173 0.0 -0.172 31.001 31.274 0.0 -0.048 31.226 0.0 -0.220 31.006 31.354 0.0 -0.070 31.284 11.174 -0.277 Pt Pv Pn Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 9 Date 8.4.21 ******* Notes ****** K Factor= 1.25 Vel= 0.77 Vel= 0.14 K Factor= 0.29 Vel= 0.89 Vel= 0.49 K Factor= -1.01 Vel= 0.26 Vel= 1.23 K Factor= -2.52 Vel = 0.57 Vel= 1.40 K Factor= -2.86 Vel= 0.77 Vel = 1.60 K Factor= -3.26 Vel= 0.94 Vel= 1.81 Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 37 to 41 41 to 45 45 to 49 49 to 52 52 to 55 55 to 58 58 to 61 61 to 64 64 to 67 67 to 70 23 to 26 26 to 29 29 to 32 32 to 35 35 to 36 Qa Qt 0.0 -20.61 21.74 21.74 18.21 39.95 14.85 54.8 10.99 65.79 6.98 72.77 1.59 74.36 -5.60 68.76 -14.02 54.74 -15.95 38.79 -18.18 20.61 0.0 20.61 62.22 62.22 60.17 122.39 51.60 173.99 16.83 190.82 0.0 190.82 Dia. "C" Pf/Ft 4.26 120.0 0.0001 4.26 120.0 0.0005 4.26 120.0 0.0009 4.26 120.0 0.0013 4.26 120.0 0.0016 4.26 120.0 0.0016 4.26 120.0 0.0014 4.26 120.0 0.0009 4.26 120.0 0.0005 4.26 120.0 0.0001 4.26 120.0 0.0012 4.26 120.0 0.0040 4.26 120.0 0.0078 4.26 120.0 0.0092 4.26 120.0 0.0092 Fitting or Eqv. Ln. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 J 21.067 0.0 0.0 0.0 0.0 0.0 Pipe Ftng's Total 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 12.000 0.0 12.000 12.000 0.0 12.000 12.000 0.0 12.000 8.600 21.067 29.667 2.400 0.0 2.400 Computer Programs by Hydratec Inc. Pt Pe Pf 42.181 30.918 0.0 0.001 30.919 0.0 0.005 30.924 0.0 0.009 30.933 0.0 0.013 30.946 0.0 0.016 30.962 0.0 0.016 30.978 0.0 0.014 30.992 0.0 0.009 31.001 0.0 0.005 31.006 11.174 0.001 42.181 30.180 0.0 0.014 30.194 0.0 0.048 30.242 0.0 0.093 30.335 0.0 0.272 30.607 0.0 0.022 Pt Pv Pn Revision: 50.52.1 Page 10 Date 8.4.21 ******* Notes ****** K Factor= -3.17 Vel= 0.49 Vel= 0.90 Vel= 1.23 Vel= 1.48 Vel= 1.64 Vel= 1.67 Vel = 1.55 Vel= 1.23 Vel= 0.87 Vel= 0.46 K Factor= 3.17 Vel= 1.40 Vel = 2.75 Vel= 3.92 Vel= 4.30 Vel= 4.30 Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 36 to 40 40 to 44 44 to 46 46 to 48 48 to 51 51 to 54 54 to 57 57 to 60 60 to 63 63 to 66 66 to 69 69 to TOR 22 to 25 25 to 28 28 to 31 31 to 34 Qa Qt -10.80 180.02 -15.09 164.93 -8.44 156.49 14.47 170.96 -20.57 150.39 -15.40 134.99 -10.33 124.66 -4.52 120.14 11.06 131.2 9.41 140.61 9.39 150.0 9.92 159.92 0.0 159.92 50.69 50.69 53.79 104.48 69.24 173.72 -66.14 107.58 Dia. "C" Pf/Ft 4.26 120.0 0.0083 4.26 120.0 0.0070 4.26 120.0 0.0062 4.26 120.0 0.0076 4.26 120.0 0.0059 4.26 120.0 0.0048 4.26 120.0 0.0042 4.26 120.0 0.0039 4.26 120.0 0.0045 4.26 120.0 0.0053 4.26 120.0 0.0058 4.26 120.0 0.0066 2.635 120.0 0.0082 2.635 120.0 0.0312 2.635 120.0 0.0800 2.635 120.0 0.0330 Fitting or Eqv. Ln. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 21 18.434 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 I 9.217 J 21.067 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Pipe Ftng's Total 10.000 0.0 10.000 10.000 0.0 10.000 4.200 0.0 4.200 5.800 0.0 5.800 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 14.000 18.434 32.434 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 44.200 30.284 74.484 12.000 0.0 12.000 12.000 0.0 12.000 12.000 0.0 12.000 11.000 0.0 11.000 Computer Programs by Hydratec Inc. Pt Pe Pf 30.629 0.0 0.083 30.712 0.0 0.070 30.782 0.0 0.026 30.808 0.0 0.044 30.852 0.0 0.059 30.911 0.0 0.048 30.959 0.0 0.042 31.001 0.0 0.127 31.128 0.0 0.045 31.173 0.0 0.053 31.226 0.0 0.058 31.284 0.0 0.493 31.777 28.777 0.0 0.098 28.875 0.0 0.375 29.250 0.0 0.960 30.210 0.0 0.363 Pt Pv Pn Revision: 50.52.1 Page 11 Date 8.4.21 ******* Notes ****** Vel= 4.05 Vel= 3.71 Vel = 3.52 Vel = 3.85 Vel= 3.39 Vel= 3.04 Vel= 2.81 Vel = 2.70 Vel= 2.95 Vel= 3.17 Vel= 3.38 Vel= 3.60 K Factor= 28.37 Vel= 2.98 Vel= 6.15 Vel = 10.22 Vet= 6.33 Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 34 -41.66 2.635 0.0 to 120.0 0.0 39 65.92 0.0133 a.a 39 -25.24 2.635 0.0 to 120.0 0.0 43 40.68 0.0055 a.a 43 -26.21 2.635 I 8.237 to 120.0 J 14.827 46 14.47 0.0008 0.0 a.a 14.47 20 112.91 4.26 a.a to 120.0 a.a 21 112.91 0.0033 a.a 0.0 112.91 20 234.80 4.26 a.a to 120.0 a.a 24 234.8 0.0133 0.0 24 -113.96 4.26 0.0 to 120.0 0.0 27 120.84 0.0040 0.0 a.a 120.84 30 49.32 4.26 0.0 to 120.0 a.a 33 49.32 0.0007 a.a 33 30.70 4.26 0.0 to 120.0 0.0 38 80.02 0.0018 0.0 38 22.13 4.26 a.a to 120.0 a.a 42 102.15 0.0029 a.a 42 19.79 4.26 0.0 to 120.0 a.a 47 121.94 0.0040 0.0 47 9.59 4.26 a.a to 120.0 0.0 50 131.53 0.0046 0.0 50 8.42 4.26 a.a to 120.0 a.a 53 139.95 0.0052 a.a 53 8.74 4.26 a.a to 120.0 a.a 56 148.69 0.0058 a.a 56 10.12 4.26 a.a to 120.0 a.a 59 158.81 0.0065 0.0 Pipe Ftng's Total 10.000 0.0 10.000 10.000 0.0 10.000 36.100 23.064 59.164 6.600 0.0 6.600 5.400 a.a 5.400 12.000 a.a 12.000 11.000 a.a 11.000 10.000 a.a 10.000 10.000 a.a 10.000 10.000 0.0 10.000 10.000 a.a 10.000 10.000 a.a 10.000 10.000 a.a 10.000 10.000 0.0 10.000 Pt Pe Pf 30.573 0.0 0.133 30.706 0.0 0.055 30.761 a.a 0.047 30.808 25.944 a.a 0.022 25.966 25.944 0.0 0.072 26.016 a.a 0.048 26.064 30.818 a.a 0.008 30.826 0.0 0.018 30.844 a.a 0.029 30.873 a.a 0.040 30.913 a.a 0.046 30.959 0.0 0.052 31.011 0.0 0.058 31.069 0.0 0.065 Pt Pv Pn Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 12 Date 8.4.21 ******* Notes ****** Vel= 3.88 Vel= 2.39 Vel= 0.85 K Factor= 2.61 Vel= 2.54 K Factor= 22.16 Vel= 5.29 Vel= 2.72 K Factor= 23.67 Vel= 1.11 Vel= 1.80 Vel= 2.30 Vel= 2.74 Vel= 2.96 Vel= 3.15 Vel= 3.35 Vel= 3.57 . Final Calculations -Hazen-Williams AMERICAN AUTOMATIC FIRE D.E. FARMS Hyd. Ref. Point 59 to 62 62 to 65 65 to 68 68 to TOR TOR to BOR BOR to UG1 UG1 to UG2 UG2 to BF1 BF1 to BF2 BF2 to UG3 UG3 to SRC Qa Qt 2.95 161 .76 6.54 168.3 8.80 177.1 10.69 187.79 159.92 347.71 0.0 347.71 0.0 347.71 0.0 347.71 0.0 347.71 0.0 347.71 0.0 347.71 250.00 597.71 Dia. "C" Pf/Ft 4.26 120.0 0.0068 4.26 120.0 0.0072 4.26 120.0 0.0080 4.26 120.0 0.0089 8.249 120.0 0.0011 8.249 120.0 0.0011 8.27 140.0 0.0008 8.27 140.0 0.0008 8.27 140.0 0.0008 8.27 140.0 0.0008 8.27 140.0 0.0008 Fitting or Eqv. Ln. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 I 9.217 J 21.067 0.0 0.0 0.0 0.0 E 21.141 0.0 0.0 E 28.468 0.0 0.0 E 28.468 0.0 0.0 Zwd 0.0 0.0 0.0 E 28.468 0.0 0.0 T 55.354 0.0 0.0 Pipe Ftng's Total 10.000 0.0 10.000 10.000 0.0 10.000 10.000 0.0 10.000 17.200 30.284 47.484 24.800 0.0 24.800 4.000 21.141 25.141 24.500 28.468 52.968 6.000 28.468 34.468 6.000 0.0 6.000 6.000 28.468 34.468 17.800 55.354 73.154 Pt Pe Pf 31.134 0.0 0.068 31.202 0.0 0.072 31.274 0.0 0.080 31.354 0.0 0.423 31.777 10.741 0.028 42.546 1.732 0.028 44.306 0.0 0.044 44.350 -2.599 0.029 41.780 8.087 0.005 49.872 2.599 0.028 52.499 0.0 0.060 52.559 Pt Pv Pn Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 13 Date 8.4.21 ******* Notes ****** Vel= 3.64 Vel= 3.79 Vel = 3.99 Vel= 4.23 Vel = 2.09 Vel = 2.09 Vel = 2.08 Vel= 2.08 * Fixed Loss = 8. 087 Vel= 2.08 Vel= 2.08 Vel= 2.08 Qa= 250.00 K Factor= 82.45 tq ,i; 'i!tection Worldwide Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 18•Ji@j The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Nu111ber (SIN} TY313 ....... Upright 5.6K, 1/2" NPT TY323 ...... Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar1t2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155° F (68°C) 175°F (79°C) 200° F (93°C) 286°F (141 °C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . Bronze Button .............. Brass/Copper Sealing Assembly ......... Stainless Steel w/TEFLON Bulb ...................... Glass Compression Screw ........ Bronze Deflector. . . . . . . . . . . . . . . . . Bronze TFP172 "" • r TFP172 Page 2 of 4 Components: 1 -Frame 4 -Bulb * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 2 -Button 3 -Sealing 5 -Compression Screw STYLE 15 or 20 ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED Assembly 6 -Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 7/16" (11,1 mm) NOMINAL MAKE-IN , -~ j ~r 2" I ~IJ __ (lo (50,8 mm) j__ 1-3/8" (34,9 mm) w~E 2-7/8" (73,0 mm) DIA. J l DEFLECTOR* CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE WRENCH RECESS (USE ONLY END "A") FIGURE2 W-TYPE6 SPRINKLER WRENCH WRENCH RECESS t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE3 W-TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 3/8±5/16" -71~ (9,5±7,9 mm) ~~ t I MOUNTING SURFACE ~:-.a;:~ 1/8" (3,2mm) CLOSURE SERIES TY-FRB MOUNTING PLATE FIGURE4 TFP172 Page 3 of 4 5/8" (15,9 mm) FLUSH 1-3/8" (34,9 mm) 3/4" (19, 1 mm) SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2mm) J 5/16±1/4" (7,9±6,4 mm) 1/2" (12,7 mm) FLUSH -'-----'--~---+-----'--'----_____.....,.,.........._ ==i_J_ ~t ~/ MOUNTING SURFACE CLOSURE SERIES TY-FRB 1/8" (3,2mm) MOUNTING PLATE 1-3/8" (34,9 mm) 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TF;;172 Page 4 of 4 P/N* 77 -XXX -X -XXX I I I SPRINKLER FINISH SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2H NPT) TY313 3 PURE WHITE (RAL9010)** POLYESTER 371 5.6K PENDENT (1/r NPT) TY323 4 SIGNAL WHITE (RAL9003) POLYESTER • Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-1 •• Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. PART NUMBER SELECTION Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright© 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. tL/f 'i!tection Products 11 Malleable Iron Threaded Pipe Unions Pressure -Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (OF) r0e) psi bar psi bar psi bar -20° -28.9° to to 300 20.7 500 34.5 600 41.4 150° 65.6° 200° 93.3° 265 18.3 455 31.4 550 37.9 250° 121.1° 225 15.5 405 27.9 505 34.8 300° 148.9° 185 12.8 360 24.8 460 31.7 350° 176.7° 150 10.3 315 21.7 415 28.6 400° 204.4° 110 7.6 270 18.6 370 25.5 450° 232.2° 75 5.2 225 15.5 325 22.4 500° 260.0° --180 12.4 280 19.3 550° 287.8° --130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c@us <8> APPROVED For Listings/Approval Details and Limitations, visit our website@ www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. MALLEABLE IRON Malleable Iron Threaded Fittings Pressure -Temperature Ratings Pressure Temperature Class 300 Class 150 Sizes ¼"-1" Sizes 1 ¼"-2" Sizes 2½"-3" (6-25mmJ /32-51 mm) (64-76mm) (OF) r0e) psi bar psi bar psi bar psi bar -20° -28.9° to to 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 150° 65.6° 200° 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 250° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 300° 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 400° 204.4 --935 64.5 750 51.7 560 38.6 450° 232.2 --725 50.0 600 41.4 475 32.8 500° 260.0 --510 35.2 450 31.0 385 26.5 550° 287.8 --300 20.7 300 20.7 300 20.7 11 oa~ Cl) C: Q)= °g: g-z 8 Q) Q) a.a. a::a:: f :::::, -c e Q.. :5 .E Cl) cri -; c:: 0 ~ § .E E Anvil Class 150/300 Malleable Iron Fittings conform to ASME c:: B16.3 and Unions conform to ASME B16.39. ~ ALL ELBOWS & TEES ¾11 (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) (..) www.anvilintl.com 17 PF-11.10 The best sprinkler pipe in the industry! c®usLISTED <§> APPROVED III ~~~ NFP.: Sprinklff Auoclatlon BULLMOOSETUBECOMPANV c®usLISTED <J9 APPROVED Ci.) NFP~ ONFSA Amertoan,i,. __ .,._,,. __ Sprinkler A••oclatlon 2 Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 ,,er' . @ ' ·~ ~"'' ,,/'/' /' ·. .r•,.r.'/ BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®usLISTED <@> APPROVED Ci] NFP• ONFSA Amertoan pt,. ,... ......... ,.~~ Sp,tnlllerAHoclallon ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY • All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. • Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. • All products are certified to ASTM A 135 and A795 Type E, Grade A. • Available in specific cut to order lengths from regular mill rollings. • More popular sizes available with coating or bare. • Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. • Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. • All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD II® MIC preventative coating. • Bull Moose Tube® sprinkler pipe is FBC™ compatible. PRODUCTS • Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. • Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. • Eddylite®: Lightwall threadable with standard outside diameter. • Eddy Flow®: Cost effective replacement for Schedule 10. • Ultra Eddy®: Lightwall roll groovable pipe. • Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. PROTECTION • Eddy Guard II®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard II®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard II® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube~ reserves the right to change product specifications without notice and without incurring obligation. 3 Bull Moose Tube's® Schedule 1 0 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 1 0 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED <§:> APPROVED [i.] NFP• ONFSA Amet'loanPIN n.,_..,.,.. .. ,.,....,..._._..,,. Spr1nkler AuoclaUon 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) {IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 \ 9.91 1: 1.81 lbs/ft · 11 ·· 2.518 11 61 I ---_J._ --=--- 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 [i 2.64 lbs/ft 1: 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft -1 7.957 19 --· 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE {IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft I 10.783 19 ---_,l ----~' - 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ~o~ BULL M0oea TUBII COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH Firelock® Outlet-T STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating½,¾, and l"/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for l¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. ®<&>~8 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. __________ _ Location ___________ _ www.victaulic.com Gasket: • Grade "E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America, Asia Pacific) • Red enamel (Europe) CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect _____ Para ___ _ Date ____________ _ Approved __________ _ Date _____________ _ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G ~taulid 10.52_1 IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS 10.52 Firelock® Outlet-T STYLE 922 DIMENSIONS y rl-r !Iz=J ¥ X T ¾ l3A6 1.28 1.83 1.10 3.87 2.56 1.1 ------~-20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 w 1 11/16 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ X ½ l3A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 ¾ l1/i6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 PA6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 X ½ 11/i6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 ¾ l3A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 l3A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2½ X ½ l3A6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 ¾ l3A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 l3A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.l mm X ½ l3A6 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 ¾ l3A6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 l3A6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52_2 ~tauhd' REV_G IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS Firelock® Outlet-T STYLE 922 PERFORMANCE 1¼ X 1 8.5 32 25 2.6 1½ X 1 8.5 40 25 2.6 2 X 1 8.5 so 25 2.6 2½ X 1 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 * Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.52 ~taulid 10.52_3 STYLE 922 INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~taulid 10.52 3355 REV G UPDATED 12/2009 VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEEUCPVC 1/2 & 3/4 inch pipe 5 thru 8 inch pipe SIZE -ROD-3/8" or 1/2" SIZE -SYSTEM PIPE -1/2" thru 8" MATERIAL -Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - c~us 203-EX 25511 "-8" <9> Approval guide -1 "-8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE -650°F. FUNCTION -Pipe hanger component ofanAFCONhanger. To support steel, CPVC or copper pipe. INSTALLATION -Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES- * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING -Part #, pipe size. 11/09 PIPE ROD 1 3/8 11/4 3/8 1 1/2 3/8 2 3/8 2 1/2 3/8 3 3/8 4 3/8 5 1/2 6 1/2 8 1/2 NFPA 13 UL 1WT. 5WT.+250 TEST LOAD 30.75 403.75 750 43.95 469.75 750 54.15 520.75 750 76.95 634.75 750 118.35 841.75 850 162.30 1061.50 1050 246.00 1480.00 1500 349.45 1996.75 2000 476.35 2631.75 2650 711.00 3805.00 4050 PIPE A B 1 1.8793 2.5259 11/4 2.1382 2.7850 1112 2.2673 2.9140 2 2.6048 3.2516 2112 3.4920 4.1150 3 3.7845 4.4311 4 4.3582 4.9992 6 6.0668 6.8180 8 7.5768 8.3290 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 310 RING RESTRAINER t Restraint SIZE -One size fits 3/4 thru 2 inch AFCON#300 Ring Hanger. MATERIAL -Carbon Steel. FINISH -Mil. Galvanized. LISTINGS -,u:\ c~us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION -To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION -Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES- * Listed only for use with AFC ON #300 Ring Hanger. ORDERING -Part# and size. ,, , ...... I .._ I ', ,...... ... ......... ...... ......... ...... ......... 300--- Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER -AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 2" nominal width ~ Not less than 3" nominal thickness (2-1/2") (depth or side f vertical member) Composite / Truss Consult truss mcinufacturer for recommended 1nstallat1on point 'Pre-drtllmg may be reqwred for GST 25-380 Tool avadable on page 10 • No pre.<Jrilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. A rovals Rod Part Model Sere~ Ultimate UL Test FM Test Box Case PP Size Number Descnpt1ons Pullout (lbs) Load (lbs) Load (lbs) Qty Qty 1/4" 8002957 GST100 1/4x 1" 210 (7/16" OSB) 25 125 670 (3/4" Ply) 1/4" 8003957 GST200 1/4x 2• 1760 (Fir) 25 125 1/4" 8004957 GST300 1/4x 3" 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4x 3/4" 564 (3/4" Ply) 25 125 ~ 3/8" 8007957 GST10 1/4x 1• 210 (7/16" OSB) 300 25 125 670 (3/4" Ply) ~~ 3/8" 8008957 GST20 1/4x2" 1760 (Fir) 850 1475 25 125 ~ 3/8" 8068925 GST20-SS 1/4x2" 1760 (Fir) 850 25 125 ~ 3/8" 8009925 GST 25-380 3/8 X 2-1/2" 2113 (Fir) 1500 25 125 ~~ 3/8" 8010957 GST30 1/4x 3" 2060 (Rr) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4x 3" 2060 (Fir) 25 125 Part#8113910 3/8" 8011925 GST40 1/4x4" 2-180 (Fir) 25 125 3/8" 8012925 GST60 1/4x6" 2230 (Fir) 25 125 1/2" 8013925 GST2 1/4x2" 1760 (Fir) 25 125 t SWROO 1/2" 8014925 GST 2.5-380 3/8 X 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST3 1/4x 3" 2275 (Fir) 25 125 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 1/2" 8017925 GST6 1/4x6" 2230 (Fir) 25 125 Nut Driver Part#8114910 SAMMY Swivel Heacf> for Wood Product Features • Eliminates distortion of threaded rod. • Saves time from traditional methods. • Accommodates up to 3 ½" x 12 pitch roof. • Allows 17° deflection from vertical. 1500 1475 25 125 Nut Driver and safe installation each time. When the face of the driver comes into Part# 8113910 . Warranty requires the use of the appropriate nut driver for installations. Not less than 2• nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" & s• pipe +---+ I Minimum 2-1/2" from bottom for branch ~nes. Minimum 3" from bottom for main lines. Exception: This requirement shall not apply to 2• or thicker naifing strips resting on top of steel beams. )'f Floor Joist • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Approvals R_od Part Model Sc~e~ Ultimate UL Test Box Case Size Number Descnpt1ons Pullout (lbs) Load (lbs) Qty Qty 1/4" 8018957 1/4" 8019957 ~ 3/8" 8020957 ~ 3/8" 8021957 ~ 3/8" 8073925 ~ 3/8" 8022925 3/8" 8023925 VERTICAL 1. Insert the appropriate nut driver into a 3/8" or 112" portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (pin 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4", 3/8", 112" or metric SWG100 SWG200 SWG10 SWG20 SWG20-SS SWG 25-380 SWG30 all thread rod, bolt stock. (The 112" requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purfin steel. 1/4x 1" 622 (Fir) 25 125 1/4x 2" 1725 (Fir) 25 125 1/4x 1" 622 (Fir) 300 25 125 1/4x 2" 1725 (Fir) 1050 25 125 1/4x2" 1725 (Fir) 850 25 125 3/8x 2-1/2" 2249 (Fir) 1500 25 125 1/4x3" 1884 (Fir) 25 125 HORIZONTAL 1. Insert the appropriate nut driver into a 3/8" or 112" portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (pin 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 114", 3/8" or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purfin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.