HomeMy WebLinkAbout1911 PALOMAR OAKS WAY; ; FPC2021-0146; PermitPERMIT REPORT Fire PE!rmit Print Date: 06/16/2022 Job Address: 1911 PALOMAR OAKS WAY, CARLSBAD, CA 92008-6511 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel#: 2120910800 Track#: Valuation: $0.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: DRAMM ECHTER FARMS -COOLER SPRINKLER Tl (56 HEADS) Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION INC KELLY SANTOS 9925 PROSPECT AVE, # STE B SANTEE, CA 92071-4376-SAN DIEGO (619) 562-3010 FEE FIRE NFPA 13 or 13R System 7-100 heads Total Fees: $553.00 Fire Department Total Payments To Date: $553.00 (city of Carlsbad Permit No: FPC2021-0146 Status: Closed -Finaled Applied: 08/06/2021 Issued: 08/17/2021 Finaled Close Out: 06/16/2022 Final Inspection: INSPECTOR: Salcedo, Felix FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION INC 9925 PROSPECT AVE, # STE B SANTEE, CA 92071 (619) 562-3010 Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov -tqca Worldwide Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Side1111all Quick Response, Standard Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are decora- tive glass bulb automatic sprinklers designed for commercial use. Dry-type sprinklers are typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (for example, sprinkler drops from unheated portions of buildings) • sprinklers and/or a portion of the connecting piping are exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors • sprinklers are used on systems that are seasonally drained to avoid freezing (for example, vacation areas) 14•»@=1 The Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contact the installing contrac- tor or product manufacturer with any questions. The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Sprinkler Identification Nu,nbers (SINsJ 3/4 in. NPT: TY3935 -Pendent TY3735 -Horizontal Sidewall 1 in. NPT: TY3235 -Pendent TY3135 -Upright TY3335 -Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved NYC Approved under MEA 352-01-E Previous New York City Approval and MEA certification numbers apply to product as shown in this data sheet. In accordance with Section BC 3502 of the Construction Code, current NYC Approvals for use in the City of New York apply to all products that contain UL or FM Approvals and Listings; therefore, not all products currently Approved for use in the City of New York will carry an actual MEA Certifi- cation number. See Tables A and B. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 3/4 in. NPT 1 in. NPT or ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi½ (80,6 lpm/bar½) MARCH 2019 Temperature Ratings See Tables A and B Finishes Sprinkler: Natural Brass, Chrome Plated, or Signal White Escutcheon: Signal White, Chrome Plated, or Brass Plated Physical Characteristics Inlet ............................. Copper Plug ............................ Copper Yoke ....................... Stainless Steel Casing ............. Galvanized Carbon Steel Insert ........................... Bronze Bulb Seat. .................. Stainless Steel Bulb ............................... Glass Compression Screw ................. Bronze Deflector . . . . . . . . . . . . . . . . . . . . . . . . . Bronze Frame ............................ Bronze Guide Tube ................. Stainless Steel Water Tube ................. Stainless Steel Spring ..................... Stainless Steel Plug Spring* ................ Stainless Steel Sealing Assembly . Beryllium Nickel w/TEFLON Escutcheon .... Carbon Steel or Stainless Steel • For 3/4 in. NPT only TFP510 'TFP510 Page 2 of 10 PLUG WITH INLET SEALING ASSEMBLY YOKE PLUG INLET SPRING BAND WATER SPRING TUBE CASING GUIDE INSERT TUBE BULB FRAME SEAT 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1, 3/4 IN. NPT, DRY-TYPE SPRINKLER ASSEMBLY PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER TUBE CASING GUIDE INSERT TUBE BULB FRAME SEAT VENT HOLE 3 mm BULB COMPRESSION DEFLECTOR SCREW FIGURE2 SERIES DS-1, 1 IN. NPT AND ISO 7-R 1 DRY-TYPE SPRINKLER ASSEMBLY Operation When the TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprinkler to activate and flow water. Design Criteria The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hor- izontal Sidewall, Quick Response (3 mm bulb) and Standard Cover- age are intended for use in fire sprin- kler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install the 3/4 or 1 in. NPT Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 in. NPT outlet or run of the follow- ing fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI 816.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 in. NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. 3/4in. NPT TY3935 Pendent TY3935 Pendent with Recessed Escutcheon with Standard Escutcheon (Figure 4) (Figure 3) with Deep Escutcheon (Figure 5) without Escutcheon (Figure 6) Temperature Bulb Finish Rating Color Code Natural I Chrome I White Natural I Chrome I White Brass Plated Polyester Brass Plated Polyester 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 1, 2 1, 2 200°F (93°C) Green 286°F (141 °C) Blue Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 in.) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 in.) Light and Ordinary Hazard occupancies only TABLE A TFP510 Page 3 of 10 TY3735 Horizontal Sidewall with Top of Deflector-to-Ceiling Distance of 4 to 12 in. (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Natural I Chrome I White Brass Plated Polyester 1*, 2* 3/4 IN. NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1 in. NPT (and ISO 7-R 1) TY3235 Pendent TY3235 Pendent TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 in. (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) TY3135 Upritt without Escutcheon without Escutc eon5 (Figure 10) (Figure 7) Temperature Bulb Finish Rating Color Code Natural I Chrome White Natural I Chrome White Natural I Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F (57°C) Oranqe 155°F (68°C) Red 1, 2, 3, 4 1, 2, 4 175°F (79°C) Yellow 1, 2, 3, 4 1,2, 4 1 *, 2*, 3**, 4 1*, 2*, 4 200°F (93°C) Green 286°F (141 °C) Blue 1, 2, 4 Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 in.) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 in.) 3. Approved by Factory Mutual Research Corporation (maximum order length of 48 in.) 4. Approved by the City of New York under MEA 352-01-E 5. The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only . Light and Ordinary Hazard occupancies only •• Light Hazard occupancies only TABLES 1 IN. NPT (AND ISO 7-R 1) SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 'TFP510 Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF \ SPRINKLER FITTING 1 - \ L_ ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS i FACE OF CEILING 2-3/16" ± 1/8" (55,6 ± 3,2 mm) 1-3/4" DIA. (44,5 mm) r:l1 3" DIA. (76,2 mm) FACE OF t ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF CEILING 1-3/8" ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) FACE OF \ SPRINKLER FITTING .....-----\ ___ L_ t ORDER LENGTHS: 1/2" to 46" (12,7 to 1168,4 mm) IN 1/4" (6,4 mm) INCREMENTS 4-1/4" ± 1/8" (108,0 ± 3,2 mm) 3-1/2" DIA. (88,9 mm) I I 2-1/2" DIA. (63,5 mm) I • • I FIGURE3 FIGURE4 FIGURE5 PENDENT TY3235 AND TY3935 WITH STANDARD ESCUTCHEON PENDENT TY3235 AND TY3935 WITH RECESSED ESCUTCHEON PENDENT TY3235 AND TY3935 WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF \ SPRINKLER FITTING IL_ ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE6 PENDENT TY3235 AND TY3935 WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING ~- SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE7 UPRIGHT TY3135 WITHOUT ESCUTCHEON 1 IN. NPT ONLY ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING FACE OF MOUNTING SURFACE 2-3/8" ± 1/8" (60,3 ± 3,2 mm) ,.____ ---=c-----'\'---------'-t 3 11 DIA. SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) II....-I....L.L~i1---::::::=:,w / T7 (76,2 mm) 5•~1~ CENTERLINE 5/1611 OF WATERWAY (7,9 mm) FIGURES TY3335 AND TY3735 HOR/ZONAL SIDEWALL WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2" to 45-3/411 (12,7 to 1162, 1 mm) IN 1/4 11 (6,4 mm) INCREMENTS 4-1/411 ± 1/811 (108,0 ± 3,2 mm) 2-1/211 DIA. FACE OF (63,5 mm) SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF MOUNTING SURFACE ~---=-1'----'-t 3-1 /2" DIA. 1---..1...--,.11~=3111 I TJ (88,9 mm) s· __j CENTERLINE 5/1611 OF WATERWAY (7,9 mm) FIGURE9 TY3335 AND TY3735 HOR/ZONAL SIDEWALL WITH DEEP ESCUTCHEON ORDER LENGTHS: ------5-1/211 to 4811 (139,7 to 1219,2 mm)-----' IN 1/411 (6,4 mm) INCREMENTS MINIMUM 2-1/4u (57,2 mm) i------1-DEFLECTOR TO MOUNTING SURFACE • FACE OF SPRINKLER FITTING '--~ SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 10 ~=t~ /3.s· 5/16" / (7,9mm) CENTERLINE OF WATERWAY TY3335 AND TY3735 HOR/ZONAL SIDEWALL WITHOUT ESCUTCHEON TFP510 Page 5 of 10 The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. See the Exposure Length section. For wet pipe system installations of the 1 in. NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1 in. x 1 in. NPT Female Adapter (P/N 80145) • 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For wet pipe system installations of the the 3/4 in. NPT Series DS-1 Sprinklers connected to CPVC piping, use in the 3/4 in. x 3/4 in. NPT Female Adapter (P/N 80142). For dry pipe system installa- tions, use only the side outlet of maximum 2-1/2-in. reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Other- wise, use the configuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. 14•Ji@j Do not install the Series DS-1 Dry-Type Sprinkler into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe threads with consequent leakage Drainage In accordance with the mm1mum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use . TFP510 Page 6 of 10 FACE OF SPRINKLER FITTING -. DSB-2 INTENDED FOR FREEZER STRUCTURES 7 EXPOSURE LENGTH (SEE DESIGN CRITERIA SECTION) FIGURE 11 EXPOSURE LENGTH STRAP TIES (ENDS ON OPPOSING SIDES OF 8001) DSB-2 BOOT ADHESIVE 1-3/4u DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER TO WET SYSTEM -. DSB-2 INTENDED FOR FREEZER STRUCTURES SIDE OUTLET PLUGGED SPRINKLER FITTING (SEE DESIGN CRITERIA SECTION) FIGURE 12 SPRINKLER FITTING HEATED AREA 1-3/4" DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 BOOT STRAP TIES (ENDS ON OPPOSING SIDES OF 8001) DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER TO DRY SYSTEM RUN OUTLET PLUGGED SPRINKLER ■ FITTING (SEE DESIGN CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER STRUCTURES FIGURE 13 SPRINKLER FITTING UNHEATED AREA WRENCH FLAT WRENCH RECESS / t " , ~ PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 16 W-TYPE7 SPRINKLER WRENCH Temperatures for Heated Area1 Ambient Temperature 40°F 50°F 60°F Exposed to (4°C) (10°C) (16°C) Discharge End of Sprinkler Minimum Exposed Barrel Length2, in. (mm) 40°F 0 0 0 (4°C) 30°F 0 0 0 (-1°C) 20°F 4 0 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: 1. For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLEC EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 11 for an example. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and sub- sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprin- kler Boot, described in Technical Data Sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Installation The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be installed in accordance with this section. General Instructions The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that TFP510 Page 7 of 10 meet the requirements of the Design Criteria section. See the Design Crite- ria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) rating to 1/8 in. (3,2 mm) for the 286°F (141°C) rating. • A leak-tight 3/4 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 10 to 20 lb-ft (13,4 to 26,8 N·m). • A leak-tight 1 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 20 to 30 lb-ft (26,8 to 40,2 N·m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright position. The deflector of a pendent or upright sprinkler must be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their cen- terline of waterway perpendicular to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 2. With a non-hardening pipe- thread sealant such as TEFLON tape applied to the Inlet threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing (see Figures 1 and 2) • the W-Type 7 Sprinkler Wrench on the Wrench Flat (see Figure 16) Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. 'TFP510 Page 8 of 10 Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (see Figures 1 and 2) to indicate if the Dry-Type Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage (for example, an improper installation or an ice plug). Close the fire protection system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). DS-1 Dry-Type Sprinklers When ordering TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Stan- dard Coverage, specify the following information: • SIN: Pendent -TY3935 or TY3235 Sidewall -TY3735 or TY3335 Upright -TY3135 • 5.6 K-factor • Deflector Style: Upright, Pendent, or Horizontal Sidewall • Quick Response, Standard Cover- age, Dry-Type Sprinkler • Order Length: Dry-Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10. After taking the measure- ment, round it to the nearest 1/4 in. increment. • Inlet Connections: 3/4 in. NPT, 1 in. NPT, or ISO 7-R 1 • Temperature Rating • Sprinkler Finish • Escutcheon Style and Finish, as applicable • Part Number (P/N) from Table D The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only. Part Numbers are for 3/4 in. and 1 in. NPT standard order sprin- klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one (1) Boot, two (2) Strap Ties, and 1 /3 oz of Adhesive (a sufficient quantity for installing one boot). P/N* 60 -XXX X -XXX TFP510 Page 9 of 10 I I-----. .------------ 01 02 03 04 05 06 07 36 33 37 32 34 43 44 I 38 Pendent with Standard Escutcheon (3/4 in. NPT) Pendent with Deep Escutcheon (3/4 in. NPT) Pendent with Recessed Escutcheon (3/4 in. NPT) Pendent without Escutcheon (3/4 in. NPT) Sidewall with Standard Escutcheon (3/4 in. NPT) Sidewall with Deep Escutcheon (3/4 in. NPT) Sidewall without Escutcheon (3/4 in. NPT) Pendent with Standard Escutcheon (1 in. NPT) Pendent with Deep Escutcheon (1 in. NPT) Pendent with Recessed Escutcheon (1 in. NPT) Pendent without Escutcheon (1 in. NPT) Sidewall with Standard Escutcheon (1 in. NPT) Sidewall with Deep Escutcheon (1 in. NPT) Sidewall without Escutcheon (1 in. NPT) Upright without Escutcheon (1 in. NPT) SIN TY3935 (Figure 3) TY3935 (Figure 5) TY3935 (Figure 4) TY3935 (Figure 6) TY3735 (Figure 8) TY3735 (Figure 9) TY3735 (Figure 10) TY3235 (Figure 3) TY3235 (Figure 5) TY3235 (Figure 4) TY3235 (Figure 6) TY3335 (Figure 8) TY3335 (Figure 9) TY3335 (Figure 10) TY3135 (Figure 7) SPRINKLER FINISH 0 CHROME PLATED 2 4 NATURAL BRASS NATURAL BRASS SIGNAL WHITE (RAL9003) ESCUTCHEON FINISH1 SIGNAL WHITE (RAL9003) SIGNAL WHITE (RAL9003) BRASS PLATED SIGNAL WHITE (RAL9003) 8 CHROME PLATED STAINLESS STEEL 9 0 2 3 4 Notes: CHROME PLATED TEMPERATURE RATINGS 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F(93°C) 286°F (141°C) CHROME PLATED 055 082 180 187 372 480 SAMPLE ORDER LENGTHS2 5.50 in. 8.25 in. 18.00 in. 18.75 in. 37.25 in. 48.00 in. 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 2. Dry-Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 in. increment. Use Prefix "I" for ISO 7-R 1 Connection (for example, l-60-360-4-055). TABLED SERIES DS-1 DRY-TYPE SPRINKLERS PART NUMBER SELECTION ·TFP510 Page 10 of 10 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 C 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fin, Protection Association; TEFLON is a registered trademark of DuPont Johnson fj Controls I II 1 ~ ~ ~ ~ MALLEABLE IRON Ill Malleable Iron Th readed Pipe Unions Pressure -Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (OF) (°C) psi bar psi bar psi bar -20° -28.9° to to 300 20.7 500 34.5 600 41.4 150° 65.6° 200° 93.3° 265 18.3 455 31.4 550 37.9 250° 121.1° 225 15.5 405 27.9 505 34.8 300° 148.9° 185 12.8 360 24.8 460 31.7 350° 176.7° 150 10.3 315 21.7 415 28.6 400° 204.4° 110 7.6 270 18.6 370 25.5 450° 232.2° 75 5.2 225 15.5 325 22.4 500° 260.0° --180 12.4 280 19.3 550° 287.8° --130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F <8> APPROVED For Listings/Approval Details and Limitations, visit our website@ www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure -Temperature Ratings Pressure Temperature Class 300 Class 150 Sizes ¼"-1" Sizes 1 ¼"-2" (6-25 mm) (32-51 mm) (OF) (OC) psi bar psi bar psi bar -20° -28.9° to to 300 20.7 2,000 137.9 1,500 103.4 150° 65.6° 200° 93.3 265 18.3 1,785 123.1 1,350 93.1 250° 121.1 225 15.5 1,575 108.6 1,200 82.7 300° 148.9 185 12.8 1,360 93.8 1,050 72.4 350° 176.7 150 10.3 1,150 79.3 900 62.1 400° 204.4 --935 64.5 750 51.7 450° 232.2 --725 50.0 600 41.4 500° 260.0 --510 35.2 450 31.0 550° 287.8 --300 20.7 300 20.7 Sizes 2½''-3" (64-76 mm) psi bar 1,000 68.9 910 62.7 825 56.9 735 50.7 650 44.8 560 38.6 475 32.8 385 26.5 300 20.7 ca ~ en c:: Q)= c..C .e-§ zc.., Q) Q) Cl.Cl. 0:::0::: ~ ::, e 0.. € E en c:ci -j c:: 0 ~ E 42 E Anvil Class 150/300 Malleable Iron Fittings conform to ASME c:: -@ Bl6.3 and Unions conform to ASME Bl6.39. ~ ALL ELBOWS & TEES%" (10 DNJ and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) www.anvilintl.com 17 PF-11 .10 the industry c®usLISTED ~ APPROVED Ml. American Fire Sprinkler Association BULLMCCSETUBECCMPANV c®usLISTED <8> APPROVED m ONFSA """'--. ........ ~~ NFP~ 2 Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 BULLMCCSETUBECCMPANV EDDY PIPE® THE SUPERIOR SPRINKLER PIPE ~~ ~ - Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®usLISTED <8> APPROVm [i.] ONFSA NFP~ ADVANTAGES OF BULL MOOSE TUBE® E □DY PIPE® FAMILY • All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. • Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. • All products are certified to ASTM A135 and A795 Type E, Grade A. • Available in specific cut to order lengths from regular mill rollings. • More popular sizes available with coating or bare. • Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. • Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. • All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD II® MIC preventative coating. • Bull Moose Tube® sprinkler pipe is FBC™ compatible. PRODUCTS • Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. • Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. • Eddylite®: Lightwall threadable with standard outside diameter. • Eddy Flow®: Cost effective replacement for Schedule 10. • Ultra Eddy®: Lightwall roll groovable pipe. • Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. PROTECTION • Eddy Guard II®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard II®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard II® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube~ reserves the right to change product specifications without notice and without incurring obligation. 3 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. c®usLISTED <§> APPROVED Ii.] ONFSA ,..------Art:.......-........ NFPI( 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE 0.0. 1.0. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE H !I ·!!· ii 1.41 lbs/ft 1.81 lbs/ft .09 lbs/ft :G47 bs!ft 3.53 lbs/ft ---4.34 lbs/ft 5.62 lbs/ft ...:-.-'L---· ---__ _t IL - SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE 0.0. 1.0. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ~/1,. .. ~<'\® ~D6 BUU.. MOOSE TUBE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent.WA Casa Grande, Al.. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH Firelock® Outlet-T STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, ¾, and 1"/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1 ¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. __________ _ Location ___________ _ www.victaulic.com Gasket: • Grade "E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America, Asia Pacific) • Red enamel (Europe) CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect _____ Para ___ _ Date ____________ _ Approved __________ _ Date ____________ _ VI CTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV G ~taulic" 10.52 1 IPS CARBON STEEL PIPE ~ HOLE CUT PRODUCTS Firelock® Outlet-T STYLE 922 DIMENSIONS www.victaulic.com 1¼ 32 X ½ 15 l3/i6 30.2 1.30 33.0 1.83 46.5 1.10 27.9 3.87 2.56 98.3 65.0 ¾ 1 3/16 1.28 1.83 1.10 3.87 2.56 20 30.2 32.5 46.5 27.9 98.3 65.0 -----+--·--------·--··-•·-1 l 3/16 1.52 2.18 i 1.10 3.87 2.56 25 30.2 38.6 55.4 27.9 98.3 65.0 1.0 0.45 1.1 0.50 1.2 0.54 1---------+-------------·--+------1------1------ 1½ 40 2 50 X X ½ 15 l3/i6 30.2 1.42 1.95 36.1 49.5 1.22 4.08 2.56 31.0 103.6 65.0 1.2 0.54 -----i-------+----··~--- ¾ 20 l3/i6 30.2 1.40 1.95 1.22 4.08 2.56 1.2 35.6 49.5 -------·----~-~~ ---~~: I ~5;~ ·--_(}1~ --1 25 ½ 15 l3/i6 30.2 1.64 41.7 2.30 58.4 -----_ . --31.0 103.6 ~~--,__ 0~ 13fi6 1.66 2.19 1.46 I 4.60 I 2.56 l 1.3 _30_.2 ____ ..,.. __ 4_2 __ ._2 _____ 55_.6 __ +--~~---~:.? _ r ~5.~ __ o.?2 1 1 3/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 __ 2_0 __ + __ __Jo.2 ___ 4_!2 55.6 __ F !_ ____ 1~.8 -+-65.o . _ o.64 ¾ l 3/16 1.64 2.19 1.46 4.60 2.56 + 1.4 1---------+-----+----+----1------2½ 65 X 76.1 mm X ½ 1 3/i6 1.91 2.44 1.71 5.40 2.56 1.6 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 ¾ 20 1.89 2.44 48.0 62.0 1.71 43.4 5.40 137.2 2.56 65.0 1.6 0.73 ----------+-----+------+-----!-·---·-----1 25 ½ 15 l 3/i6 2.13 2.79 1.71 5.40 2.56 30 2 48 5 62 0 43 4 139 7 65 0 30 2 54 1 70 9 43 4 1 1372 65 0 1 3/i6 191 --244 ~-5 50 -l-;, 56-- __ 3_¼_-t-_1¼ ---189 ,--244--1 71 . 550 I -256 +-- 20 30 2 48 0 62 0 43 4 139 7 65 0 I ~ -·-----------------4----- 1 l3/i6 213 2 79 1 71 5 50 2 56 25 30 2 54 1 10 9 43 4 139 1 65 o I 1.6 0.73 1.6 0.73 1.6 0.73 1.7 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 ~taulic' REV G IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS Firelock® Outlet-T STYLE 922 PERFORMANCE 1¼ X 1 8.5 32 25 2.6 ---1½ X 1 8.5 40 25 2.6 ·"---------2 X 1 8.5 50 25 2.6 ---2½ X 1 8.5 65 25 2.6 ----~-- 76.1 mm X 1 8.5 25 2.6 * Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV r, -- ---- ~taulic' 10 '1? ~ Firelock® Outlet-T STYLE 922 INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~taulic' 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEEUCPVC 1/2 & 3/4 inch pipe 5 thru 8 Inch pipe SIZE -ROD-3/8" or 1/2" SIZE -SYSTEM PIPE -1/2" thru 8" MATERIAL -Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL- c~us203-EX 25511"-8" <§> Approval guide -1 "-8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE -650°F. FUNCTION -Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION -Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES- * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING -Part#, pipe size. 11/09 PIPE ROD 1 3/8 1 1/4 3/8 11/2 3/8 2 3/8 2 1/2 3/8 3 3/8 4 3/8 5 1/2 6 1/2 8 1/2 NFPA 13 UL 1WT. 5 WT.+250 TEST LOAD 30.75 403.75 750 43.95 469.75 750 54.15 520.75 750 76.95 634.75 750 118.35 841.75 850 162.30 1061.50 1050 246.00 1480.00 1500 349.45 1996.75 2000 476.35 2631.75 2650 711.00 3805.00 4050 PIPE A B IT B 1 1.8793 2.5259 1 1/4 2.1382 2.7850 1 1/2 2.2673 2.9140 2 2.6048 3.2516 il 2 1/2 3.4920 4.1150 3 3.7845 4.4311 4 4.3582 4.9992 6 6.0668 6.8180 8 7.5768 8.3290 @@Ii) P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 310 RING RESTRAINER Restraint SIZE -One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL-Carbon Steel. FINISH -Mil. Galvanized. LISTINGS -fu.'\ c\e/us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION -To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION -Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES- * Listed only for use with AFCON #300 Ring Hanger. ORDERING -Part# and size. ........ , ... I ', I ', ,...... ... ......... ...... ........................ 300--- Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warrnnty restriction will apply. DJSCLAJMER -AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited lo loss of business or profit, when non-AFCON products have been, or are used. 1/08 2· nominal width ~ Not less than 3" nominal thickness (2-1/2") (depth or side f vertical member) Composite/ Truss Consult truss manufacturer for recommended installation point "Pre-dnllmg may be reqwred for GST 25-380. Tool available on page 10 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. A I Rod Part M d I Screw Ultimate UL Test FM Test Box Case pprova s Size Number O e Descriptions Pullout (lbs) load (lbs) load (lbs) Qty Qty 1/4" 8002957 GST 100 1/4 X 1" 210 (7/16'' OSB) 25 125 670 (3/4" Ply) 1/4" 8003957 GST 200 1/4 X 2" 1760 (Fir) 25 1/4" 8004957 GST 300 1/4x 3" 2060 Fir 3/8" 8006957 GST .75 1/4 X 3/4" 564 (3/4" Ply) ~ 3/8" 8007957 GST10 1/4x 1" 210 (7/16" OSB) 670 (3/4" Ply) :@. .. ~ 3/8" 8008957 GST 20 1/4 X 2" 1760 (Fir) 3/8" 8068925 GST 20-SS 1/4 X 2" 1760 (Fir) 3/8" 8009925 GST 25-380 3/8 X 2-1/2" 2113 (Fir) 3/8" 8010957 GST30 1/4x 3" 2060 Fir 3/8" 8069925 GST 30-SS 1/4x 3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4x4" 2180 Fir) 25 125 3/8" 8012925 GST60 1/4 X 6" 2230 (Fir) 25 125 1/2" 8013925 GST2 1/4 X 2" 1760 Fir 25 125 1/2" 8014925 GST 2.5-380 3/8 X 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" 2275 Fir 25 125 1/2" 8016925 1/4x4" 2180 (Fir) 25 125 1/4x6" 2230 (Fir) 25 125 SAMMY Swivel Head® for Wood Product Features • Eliminates distortion of threaded rod. • Saves time from traditional methods. • Accommodates up to 3 ½" x 12 pitch roof. #14 Black Nut Driver Part# 8113910 }#14SWRed Nut Driver Part# 8114910 Nut Driver nd safe installation each time. When the face of the driver comes into Part # 811391 o Warranty requires the use of the appropriate nut driver for installations. A•~ w WA"iUUJ.-V Not less than 2' nominal width (1-1/2') up to 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe +---+ I Minimum 2-1/2" from bottom for branch lines. Minimum 3' from bottom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. ~ Floor Joist • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. A I Rod Part M d I Screw Ultimate UL Test Box Case pprova s Size Number O e Descriptions Pullout (lbs) Load (lbs) Qty Qty 1/4" 8018957 1/4" 8019957 3/8" 8020957 3/8" 8021957 I 3/8" 8073925 #14 SW Red 3/8" 8022925 Nut Driver 3/8" 8023925 Part# 8114910 VERTICAL 1. Insert the appropriate nut driver into a 318" or 112" portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (pin 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 114", 3/8", 112" or metric all thread rod, bolt stock. (The 112" requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SWG 100 SWG 200 SWG10 SWG20 SWG20-SS SWG 25-380 SWG30 1/4x 1• 622 Fir} 25 125 1/4 X 2" 1725 (Fir) 25 125 1/4x 1" 622 Fir) 300 25 125 1/4 X 2" 1725 (Fir) 1050 25 125 1/4x2" 1725 Fir) 850 25 125 3/8 X 2-1/2" 2249 (Fir) 1500 25 125 1/4x 3" 1884 Fir 25 125 HORIZONTAL 1. Insert the appropriate nut driver into a 318" or 112" portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (pin 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.