Loading...
HomeMy WebLinkAbout1775 DOVE LN; ; FPC2022-0002; PermitPERMIT REPORT Fire Permit Print Date: 06/15/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 1775 DOVE LN, CARLSBAD, CA 92011-4048 FIRE-Construction Commercial Work Class: 2150507000 Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Fire Alarm {city of Carlsbad Permit No: FPC2022-0002 Status: Closed -Finaled Applied: 01/04/2022 Issued: Finaled Close Out: 06/13/2022 Final Inspection: INSPECTOR: Cheung, Nathaniel Description: DOVE LIBRARY -REPLACEMENT OF EXISTING FIRE ALARM SYSTEM (240 DEVICES, ADDRESSABLE) Applicant: GREGORY COX 920 S ANDREASEN DR, # STE 102 ESCONDIDO, CA 92029-1936 (619) 719-2633 FEE FIRE Tl Fire Alarm System Total Fees: $682.00 Fire Department Total Payments To Date: $682.00 FPContractor: AD T COMMERCIAL LLC PO BOX 310702 BOCA RATON, FL 33431-0000 (561) 989-7919 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov AMOUNT $682.00 $0.00 Page 1 of 1 AflT- commercia1 Equipment Specifications Fire Alarm System Replacement FOR DOVE LIBRARY 1775 DOVE LANE CARLSBAD, CA 92011 ADT Commercial 1O107 Carroll Canyon Rd. San Diego, CA 92131 Phone (760) 233-9787 I Fax (760) 233-9788 C-10, C-16 I C-1065604 Hon~~~ I Addressable Fire Alarm Control Panels ~KNICHf 6820 Addressable Fire Alarm Control Panel The 6820 is an addressable fire alarm control panel (FACP) and is a direct replacement for the 5820XL FACP. The 6820 can be configured to achieve a point capacity of 1110 points and connect up to 17 panels in a single communications link. The 6820 has one built-in signaling line circuit (SLC), which can support 159 (SK) System Sensor<e) sensors and 159 SK modules or 127 (SO) Hochiki® devices per loop. To increase point capabilities, additional SLC loops can be added using the 6815 SLC expander for SK devices or the 5815XL expander for SD devices, increasing the point capacity to a maximum of 1110 points for SK devices and 635 points for SD devices. Three additional SLCs are needed to reach 1110 points CSK devices). Four additional SLCs are needed to reach 635 points (SD devices). A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. It also has a built-in, dual- line POTS and IP communicator with additional cellular options available. The 6820 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT® wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6820 compatible devices. FEATURES & BENEFITS • Capable of providing • Connect up to 17 • Built-in dual path up to 1110 points for panels on one site with POTS and IP enhanced design convenient single-communications with flexibility. Additional point access using the optional cellular Signal Line Circuits SK-NIC Network models available for can be added until Interface Ca rd. reliable backup maximum point levels Connected panels can reporting are reached have mixed compatible • 6860 annunciator with • Built-in USB interface FACP models a 4 x 40 large display for convenient and • Convenient • JumpStart® auto quick programming field-upgradeable programming reduces firmware installation time 6820 The 6820 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre-trouble maintenance alert, a built-in sensortestto comply with NFPA 72 calibration testing requirements, and calibration trouble alert. The 6820 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • Four user- programmable buttons minimize time spent executing complex or routine tasks • Flexput'"' circuits can be individually programmed to function as notification circuits, auxiliary power outputs, or initiating circuits that support both 2-and 4-wire smoke detectors SIGNAL LINE CIRCUIT (SLC) The 6815 signal line circuit (SLC) supports multiple device types of SK protocol, while the 5815XL signal line circuit (SLC) supports multiple device types of SO protocol. You cannot mix SO and SK SLC devices on a FACP. The 6820 has one built-in signaling line circuit (SLC) which supports multiple devices. Additional points can be added using the 6815 SLC expanders to increase overall capacity to system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4-to ?-digit operator's code. PROGRAMMING 1,110 maximum points CSK devices) or by The 6820 system offers several options adding up to four 5815XL SLC expanders to simplify and speed-up programming. to reach 635 maximum points (SO devices). The number of SLCs which can be used within one system is limited by point count. (See the Manual for additional information.) The 6820 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Troubles (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6820 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touch pad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, Page 2 of 4 -351610:B 9/26/2018 JumpStart® AutoProgramming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on-site access to current system programming. Programming can also be accomplished using the Windows®-based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows<'!' software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft" Windows"''. ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6820 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station: remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory CDACT non-coded) signaling services. • UL Listed: S2766 • CSFM: 7165-0559:0500 • FDNY: COA# 6249 • FM approved ORDERING INFORMATION 6820: Addressable Fire Alarm Control Panel. (Red cabinet). COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880:The 5880 LED/ 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6820 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SO or SWIFT devices. 53623: SK Devices Data Sheet 53624: SO Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.silentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector C135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (190°F), white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed tern peratu re) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module 8300-6(-IV): 6" base for SK-W Series B210LP: 6" mounting base 8501(-WHITE, -IV, -BL): 4" Flangeless base 8501: 4" Flangeless mounting base B200S(-IV, -WH): Intelligent sounder base B200S: Intelligent sounder base B200S-LF(-IV, -WH): Low-frequency intelligent sounder base. B200S-LF: Low-frequency intelligent sounder base B224RB(-IV, -WH): Relay base B224RB: Relay base 8224BI(-IV, -WH): Isolator base 822481: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SDSOS-6I8: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6' relay base SDSOS-6S8: Addressable 6" sounder base SDSOO-AIM: Addressable input module (switch input) SDSOO-ANM: Addressable notification module SDSOO-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the SD505-DUCTR SDSOS-DUCT: Addressable Duct Smoke Detector. SDSOS-DUCTR: Addressable Duct Detector housing with relay base. SDSOS-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F(0°C-37°Cl SDSOO-LIM: Addressable Line isolator module 5D500-MIM: Addressable Mini input monitor module (switch input) 5D505-PHOTO: Photoelectric smoke detector 5D500-PS/-PSDA: Addressable Single or dual action pull station SDSOO-SDM: Addressable smoke detector module AUDIBLEfVISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W' denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SO) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and B510W 4" base WSK-HEAT: Wireless Heat, (135°F fixed temperature) and 8510W 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 6815: Each Single Line Circuit allows for an additional 159 SK modules and 159 SK sensors to be added to the system-up to 1,110 total points. Supports System Sensor SK devices only. 5815XL: Each Single Line Circuit provides an additional 127 SD devices to be added to the system -for a maximum of 635 points. Supports SD devices only. 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay Interface. Provides 10 Form C relays. 5824: Serial/Parallel Printer Interface Module for printer connection. 5895XL: Power Supply with six Flexput™ circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/B"W x 10-3/16"H x 3"0 COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL-MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm';;i receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6820. SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 -351610:B 9/26/2018 6820 Technical Specifications PHYSICAL Overall Dimensions: 16.36" W x 26.37" H x 3.91" D Shipping Weight: 32 lbs Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (non- condensing) ELECTRICAL 6820 Primary AC: 120AC @ 60Hz, 3.3A Total Accessory Load: 6A@ 27.4VDC power-limited Standby Current: 190mA Alarm Current: 250mA Battery Charging Capacity: 7 to 35AH Battery Size: 18AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 www.silentknight.com FLEXPUT CIRCUITS Six programmable circuits which can be programmed individually as: Notification Appliance Circuits: 3A @ 27.4VDC per circuit, power-limited (with a panel maximum current of 6A) Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiating Circuits (Circuits 5 and 6 Only): lO0mA @ 27.4VDC per circuit, power limited Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits WIRING: See the product manual for wiring details 351610 I B I 09/18 © 2018 Honeywell International Inc. Flexput"', Honeywell@, JumpStart"'. Silent Knight", SWIFP ', and System Sensor'' are reg istered trademarks of Honeywell International Inc. Hochiki® is a registered trademark of Hochiki Corporation. Microsoft" and Windows"' are registered trademarks of Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell m ILENT. ~KNIGHT Honeywell 5860 rr!!ISILENT' LliKNIGHT Remote Annunciator The 5860 remote annunciator, can be used to operate and program Honeywell Silent Knight fire alarm control panels (FACPs) from anywhere within the system. The 5860 features include an BO-character backlit LCD providing easy-to understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The 5860 annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820: Add ressable fire alarm control pane l with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808: Ad dressable fire alarm control panel with up to 198 addressable points 6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addres sable fire alarm control panel 5820XL-EVS: Addressa ble fire alarm control panel with an emergency communication systems 5808: Addressa ble fire alarm control panel 5700: Addressable tire alarm control panel FEATURES & BENEFITS • BO-character backlit LCD display (4 lines with 20 characters per line) • Tactile/ audible feedback when a key is pressed on the annunciator • Uses the RS-485 SBUS to interface with the panel • Supportfor simultaneous use of multiple 5860s • Easily view current status by alarms, supervisories, or troubles • Five Status LEDs • Available in red or Light gray color 5860/SSG0R • Accommodates wiring lengths up to 6000 ft. from the control panel for added design and install flexibility • Accepts user codes or fire fighter's key • Larger keypad buttons makes it easier to maneuver for system reset and silencing 5860 Technical Specifications Wire Runs Up to 6000 Feet From FACP SBUS 5860 5860 5860 • Up to Eight 5860s Per 5700 or 6700 System • Up to 12 5860s Per 5808, 6808, 5820XL, or 5820XL-EVS System Compatible Silent Knight FACP • Up to 16 5860s per 6820 or 6820EVS System 5860 Features PHYSICAL Dimensions: 9.l"W x 7.4"H x 1.5"0 (23.lW x 18.8H x 3.80 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color: 5860R: Red; 5860: Gray ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10% -93% non-condensing) ELECTRICAL Operating Voltage: 24VDC Standby Current: 20mA Alarm Current: 25mA For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 064 72 800-328-0103 ORDERING INFORMATION 5860: Remote Annunciator, four line (4x20) LCD annunciator with 20 characters per line. Gray 5860R: Remote Annunciator, four line (4x20) LCD annunciator with 20 characters per line. Red ACCESSORIES 5860TR: Red Trim Ring for surface mounting 5860TG: Gray Trim Ring for surface mounting AGENCY LISTINGS AND APPROVALS UL listed CSFM approved Meets NFPA 72 requirements FM approved MEA approved Doc 3502241 Rev JI 12/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight') and Honeywell~ are registered trademarks of Honeywell International. Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support. call 800-446-6444. Honeywell r';!!ISILENT" UKNIGHf LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0559:0500 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 2 Silent Knight Model 6820 and 6820-EVS, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only) and mass notification services (6820-EVS). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model 6820 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAG Expander 5880 LED 1/0 Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network lnerface Card SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SKC Seismic Complaince Kit 5815XL SLC Expander 6815 SLC Expander Model 6820EVS System Components: EVS-50W 50 Watt Amplifier EVS-1 00W 100 Watt Amplifier EVS-125W 125 Watt Amplifier *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 RATING: INSTALLATION: MARKING: APPROVAL: Listing No. 7165-0559:0500 EVS-100WBU External Backup Amplifier EVS-INT50W 50 Watt Internal Amplifier EVS-CE4 Circuit Audio Expander EVS-SW24 24 Switch Expander EVS-VCM Voice Control Module EVS-LOC Local Operator Control 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED 1/0 Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network lnerface Card SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SCK Seismic Complaince Kit 5815XL SLC Expander 6815 SLC Expander SK-NIC-KIT Primary Operating Power Supply: 120VAC, 60HZ, 3.25A Secondary Operating Power Supply: 24VDC, 750 mA, 55Ah Page 2 of 2 In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices and for mass notication. Refer to listee's Installation Instruction Manual for details. *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 TELGUARD Telguard Portal Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. TG-7FS LTE-V CELLULAR ALARM COMMUr\JICATOR FOR LTE NETWORKS P/N: TG7LVF01 d COMMERCIAL FIRE PRODUCT FEATURES 1-Certified for use on Verizon's LTE network for long, sunset- free installation. I-Meets UL 864 requirements for sole, primary or backup path communications. I-Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS L TE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. Telguard Cellular Service Telguard Cellular Service provides Verizon LTE network coverage for all Telguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. -Advanced Reliability • Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. • Automatic self-tests with central station notification ensure the cellular system is operating. • Available relay output for tripping the alarm control panel when a trouble condition occurs. TELGUARD Power • Transmit Power: 200mW in all bands. Power Consumption: 60mA (Standby) 250mA (Transmission). • Transformer: 12VAC, 800mA UL listed plug-in. Radio Transceiver • LTE Bands: 4 & 13. • Antenna: 9" dipole with 2d8i gain 12 ft of cable and universal mounting bracket. • FCC part 15, 27 and 68 compliant. Physical Details • TG-7FS LTE-V: 7.5" H x 11.5" W x 3.5" D. • Shipping Weight: 8Ibs. • Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). Standard Features • Full data reporting. • Automatic self-test (60 min. & daily). • Power supply with battery harness. • Locking, red metal enclosure. • Two programmable supervisory trip outputs. • Supports virtually all alarm formats (Contact ID, SIA2, and others) using dial capture for universal panel compatibility. • Telephone line monitor built-in, with Standard Line Security. TG-7FS LTE-V P/N: TG7LVF01 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. • HGDL-0: High gain directional antenna. • EXDL-0: External antenna. UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems • For the most current product specifications and UL Listings visit www.Telguard.com. Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright ©2017 Telular Corporation• All Rights Reserved LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1402:0110 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES TELULAR CORP.3325 Cumberland Blvd, NE, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (800) 229-2326 Fax (678) 945-1651 Email: customerservice. telular@ametek.com Models *TG7LV001, *TG7LVA01 , *TG7LVF01 and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations 120 Vac In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *04-07-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 SIGNALING @ LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector • 2 Key ring hooks to hold system keys • Business card holder for key contacts • Overall Dimensions are 12" x 13" tall and 2 ¼ deep • 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available • Standard ¾"cat 30 key lock other lock as- semblies available • Solid stainless steel piano hinge • Permanently screened white ink 1" high "Fire Alarm Documents" • Legend sheet for passwords and system information FAD ACE-11 FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FOB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. II] ~-.-·. NFP~ NEMBER l •ll!!fi~~.-1111! ,·=~-= ~ .... ., ... ~ Made In U .S.A. ISO9001 R GIST RED COMPANY Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 L T10559 Rev.D 1/2 No Excuses, Just Solutions! SPACEAGE ----------- ELEcTRoNrcs. INC./ Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1 /2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Space Age (;:lectronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! USB Storage Interface ~ Requires Standard USB-B Connector Key Ring Hooks ForreplacementbrmsorderPIN:EA0316(0ty.10) Property Information ~::s~property __ _ =;:~·-· """_'-_-_-_-_- Certifications and Approvals 16.1 System Installation Contractor: Thi11ystem,u1pedfledhereln,hatbeenlnstalled1nd teswd1CCOfdiogtoINNFPAst:andardlcitedhereln. Signed: __ _ Printed name. __ O..te:_,_,_ ~•nitatio11: __ Ph<>n,· __ _ 16.5 Authority Having Jurisdiction· lhavewltnessed1satlsfacta,y1CCeptancelestofthia ,yst11mancltlndlttobelnltaled1ndoperatwlgproperly lnIcc«d1ncewlthlts1pproYedplans1ndspeclrieatlons, :i:,~=r:.d::::roper.ilions, ■ndwlth afl Slgnod __ _ Printed name. __ Date:_/_/_ ~•nlzatlon:_· __ Phone: __ _ Equipment Information _,-SpaceAgeEledronics,lnc. Minimum Required Documentation {SIG-FUN) (RetereraNFPA-722013SeC11on7.2.1) 1 ~ltJ!":~,:~~,_~:::nlY_"••-"'oc_"""'_" ___ _ u:~'J:."~~=·~11.•i:::i:•nancedocumentatlonlnaccordancewlth5ectlon7.6 &erling,MA01564 800-486-1723 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part# Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc# ED0479 for legal disclaimer ED0549 L T10559 Rev. D 2/2 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STA TE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0553:0110 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SPACE AGE ELECTRONICS58 Checkett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-47 40 Email: bobs@1sae.com Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IF1, IFX/A and IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number and UL label. Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 de This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 Honeywell 5496 r,?!SILFNT' LliKNIGHf Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMS ECO, and Wheelock®. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with the Honeywell Silent Knight series fire alarm control panels (FACPs). The 5496 is the cost-effective solution· for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence pattern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power (configurable for constant, resettable, or door holder power). Compatibility The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820 I 6820EVS • 5820XL / 5820XL-EVS • 6808 • 6700 • 5808 • 5700 FEATURES & BENEFITS • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • 24 VDC filtered output voltage • Built-in synchronization for appliances from Gentex, AMS ECO, System Sensor, and Wheelock • Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • NAcs are programmable as notification appliance circuits, or as auxiliary power to be used as constant, resettable, or door holder power • 3 amps per output circuit • Ground fault detector • CSFM approved 5496 • Communicates to the FACP via 4-wire SBUS (wire runs up to 6000 ft) • AC loss delay option shuts off power to non-essential high current accessories like magnetic door holders • MEA approved • L1ghtwe1ght design adds to ease of installation and reduces shipping costs • ANSI Cadence pattern output capability built-in • UL 864,1481 & 1971 listed • OSHPD (CA) OSP-0065-10 (see accessories) 5496 Technical Specifications Output 1 Output 2 Output 3 Output 4 PHYSICAL 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power Overall Dimensions: 16' H x 12.25' W x 3" D (40.6 x 30.9 x 7.6 cm) Shipping Weight: 8.7lbs ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non- condensing) ELECTRICAL: AC Input: 120VAC at 2.7A Output: 24VDC at 6A Standby&Alarm Current: lOmA Notification/Aux. Power Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) 1 Class A & 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) Notification Circuit Output: 20.4 -27.3VDC @ 3.0A each End-of-Line Resistance: 4 .7k W EOL resistor For more information Learn more about Silent Knight's Product and other products available by visiting www.si lent knight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 064 72 800-328-0103 www.silentknight.com SBUS Communication To a Compatible Silent Knight FACP required on each Class B circuit Battery Charging Capacity: 7.0 -35.0AH ORDERING INFORMATION 5496: Intelligent Power Module ACCESSORIES RBB: Remote Battery Box Accessory Cabinet. 16" Wx 10" H x6'' D (406 mm Wx 254 mm H x 152 mm D) SK-SCK: Seismic Compliance Kit AGENCY LISTINGS AND APPROVALS • CSFM approved • NFPA 72 • UL listed • FM approved • City of NY: 429-90-E Vol XIV Doc 3503871 Rev Fl 11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows. and the Windows Logo are registered trademarks or traden,arks of Microsoft Corporation. System Sensor@' and Honeywell~ are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support. call 800-446-6444 Honeywell ~SILENT. UKNIGIIT LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0559:0171 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Model 5496 Intelligent power module. The power module consists of the following: Model 054960; main board Model 122599; enclosure Model SK-F485C; fiber to sbus converter Refer to listee's data sheet for additional detailed product description and operational considerations. 120 Vac In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a power module for use with listee's Models 5820XL and IFP-1000 (CSFM No. 7165-0559-135), 5808 and IFP-100 (CSFM No. 7165-0559-142), IFP-50 and 5700 (CSFM No. 7165-0559-144), IFP-100ECS and IFP-1000ECS (CSFM No. 7165-0559-169) fire alarm control units. Refer to listee's Installation Instruction Manual for details. 03-06-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 Honeywell ri!ISILENT' LliKNIGHT SK-PULL-SA/ SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel CFACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor'"J PN BG-TR) trim ring if the station is being semi-flush mounted. FEATURES & BENEFITS • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets ADA requirement for 5 lbs maximum pull force to active • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Shell, door, and handle molded from durable LEXAN' SK-PULL-SA SK-PULL-DA • Reliable analog communications for trouble-free operation • Braille text on station handle • Rotary address switches for fast installation • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • MEA Listed SK-PULL-SA/ SK-PULL-DA Technical Specifications PHYSICAL Dimensions: 5.5" H x 4' W x 1.45" D (14 x 10.2 x 3.7cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (S PST) normally open (N/0) switch which closes upon activation of the pull station ELECTRICAL Operating Voltage: 15 -32VD C SLC Standby and Alarm Current: 350µA Wire Gauge: Up to 12AWG (3.1 mm2) ENVIRONMENTAL Operating Temperature: 32°F-120°F (0°C- 490C) Humidity: 10%-93% non-condensing For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 ORDERING INFORMATION SK-Pull-SA: Single Action Pull Station SK-Pull-DA: Dual Action Pull Station ACCESSORIES BG-TR: Optional trim ring. SB-1/O: Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to SK-Pull-SA and SK-Pull-DA COMPATIBILITY The SK-PULL-SA AND SK-PULL-DA are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system Doc 350135 I Rev EI 11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or tradernarks of Microsoft Corporation. Silent Knight®, System Sensor~ and Honeywell"' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell r?!Sll.ENT ll.':ilKNIGHT LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-0559:0161 Page 1 of 1 7150--FIRE ALARM PULL BOXES SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. 7150-0028:0199 04-16-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 Honeywell r,?!SILENT' ~KNIGHT SK-MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-MONITOR is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. INSTALLATION The SK-MONITOR mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SM B500) is available from Silent Knight. FEATURES & BENEFITS • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • SEMS screws for easy wiring • UL Listed • Rotary address switches for fast installation SK-MONITOR SK-MONITOR Technical Specifications PHYSICAL Height: 4.5"H x 4" W x 1.25"0 (11.4 X 10.2 X 3cm) Shipping Weight: 6.3 oz (196 g) ELECTRICAL Operating Voltage: 15 -32VDe Current Draw (LED on): 5.0mA max Operating Current (LED flashing): 375~tA Standby Current: 400 µA max @ 24 voe Cone communication every 5 sec with 47K EOL); 550 µA max @ 24 voe (one communication every 5 sec with EOL <lK) 5.5 mA (with LED latched on) LED Current: 5.5 mA (with LED latched on) End-of-Line Resistance: 47K Q Initiating Device Circuit Wiring Resistance: 1,500 Qmax SLC Loop Resistance: 40 Q max. ENVIRONMENTAL Operating Temperature: 32°F-120°F C0°e - 49°C) Humidity: 10%-93% non-condensing For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 ORDERING INFORMATION SK-MONITOR: Monitor Module ACCESSORIES. SMB500: 4" Square surface mount electrical box COMPATIBILITY The SK-MONITOR is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency mass notification system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system Doc 350131 I Rev GI 11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows. and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight~'. System Sensor~ and HoneyweW' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific · applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell n!!SILENT. UKNIGHT LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0559:0155 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK-Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, I DP-Monitor, IDP-Minimon, !DP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, !DP-Control, !DP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules.and *IDP-RELAYMON-2, *SK-RELAYMON-2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. 16-33 voe Primary In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 SK-PHOTO-W SERIES Addressable Photoelectric Smoke Detectors The Silent Knight® SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two-wire SLC connection • LEDs blink every time the unit is polled • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device-type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper-resistant feature • Designed for direct-surface or electrical- box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws for wiring of the separate base • Optional remote, single-gang LED accessory • Optional sounder, relay, and isolator bases Honeywell ~SILENT ~KNIGHT SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Sensitivity: -UL Applications: 0.5% to 4.0% per foot obscuration. -ULC App lications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter -8300-6: 6.1" (15.6 cm) diameter -8501: 4' (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W: 32°F to 122°F (0°C to 50°C) • SK-PHOTO-T-W: 32°F to 100°F(0°C to 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% -93% non- condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 -32 volts DC peak Standby current (max. avg.): 200µA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.lm). For specific information regarding detector spacing, placement, and special applications refer to N FPA 72. A System Smoke Detector Application Guide, document A05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S6173 • FM Approved • CSFM: 7272-0559:0512 351634 I B I 07 /19 ©2019 Honeywell International Inc. Silent Knighf:' and System Sensor'~ are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico Honeywell ~SILENT. ~KNIGHT SK-HEAT-W SERIES Addressable Heat Detectors The Silent Knight® SK-H EAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 180°F/88°C fixed high-temperature detectors and are direct replacements for the SK-HEAT Series heat detectors. The point ID address, set using rotary decimal switches, provide specific detector locations. These thermal detectors provide effective, intelligent property protection in a variety of applications. • SK-HEAT-W offers 135°F fixed thermal detection. • SK-H EAT-ROR-W offers 135°F fixed and rate-of-rise thermal detection. • SK-HEAT-HT-W provides fixed high-temperature detection at 190°F. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Sleek and stylish contemporary design • Advanced thermal technology for fast response • Fixed temperature model (SK-HEAT-W) factory preset to 135°F (57°C) • Rate-of-rise model (SK-HEAT-ROR-W), 15°F (8.3°C) per minute • High temperature model (SK-HEAT-HT-W) factory preset to 190°F (88°C) • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two-wire SLC connection • LEDs blink every time the unit is polled • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device-type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper-resistant feature • Designed for direct-surface or electrical- box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws for wiring of the separate base • Optional remote, single-gang LED accessory • Optional sounder, relay, and isolator bases • Optional flanged surface mounting kit Honeywell ~SILENT ~KNIGHT SK-HEAT-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Size: 2.0" (5.3 cm) high; base determines diameter -B300-6: 6.1" (15.6 cm) diameter -B501: 4" (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Operating temperature range: SK-HEAT-W, SK-HEAT-R0R-W:-4°Fto 100°F (-20°C to 38°C) SK-HEAT-HT-W:-4°Fto 150°F (-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m) center to center; FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity: 10% -93% non- condensing Thermal ratings: Fixed-temperature set point 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 -32 volts DC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled) LED current (max.): 4.5mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Cli ntonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S6228 • FM Approved • CSFM: 7270-0559:0511 351637 I B I 07 /19 ©2019 Honeywell International Inc. Silent Knight!' and System Sensor;[,:· are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico Honeywell ~SILENT. ~KNIGHf ~SYSTEM '--~ SENSOR® Select Series Mounting Base Options System Sensor mounting bases and kits provide a variety of installation options tor detectors in any application. Features • Bases enable quick and secure detector plug-in • SEMS screws provide easy wiring connection • Support for 12-24 AWG provides installation flexibility • Multiple base formats meet application requirements • Standard white color with ivory and black options • UL 268 compliant • Mechanical locking feature restricts removal of attached sensor head Specialty Base Features • Pre-wired mounting plate simplifies installation • Application driven feature sets • Sounder bases both UL 268 and UL 464 compliant Agency Listings SIGNALING @ LISTED S911 rii ~ 3062622 4· & 6" bases: 7300-1653:0109 Relay & Isolator bases: 7300-1653:0126 Sounder bases: 7135-1653:0213 Low-frequencybases:7300-1653:0238 To meet local code and application requirements, System Sensor offers standard 4" and 6" bases, as well as, specialty base designs including relay, isolator, sounder and low frequency sounder options for Select Series detectors. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+and -), and remote annunciator connections. Communication takes place over the power (+and -) lines. The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The Select Series specialty bases support application driven requirements. The bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. Relay bases (B224RB-WH/B224RB-IV) provide one form C contact relay for control of auxiliary functions, such as door closure and elevator recall . The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60 ms to 100 ms, while the activation time for the long delay is 6 sec to 10 sec. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/B224B1-IV) allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. The Select Series sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The t Consult your fire alarm control panel manufacturer for compatibility with the addressable model of the sounder base. SPDS901-00 • 04/04/2018 • Page 1 Electrical Specifications: B200S-WH, B200S-IV External Supply Electrical Ratings External Supply 16 to 33 voe (VFWR) Voltage Standby Current: 500 µA maximum Alarm Current: 35 mA maximum (at high volume setting); 15 mA maximum (at low volume setting) SLC Electrical Ratings SLC Operating 15 to 32 voe Voltage: SLC Standby 300 µA maximum Current: Sound Output High Volume: Low Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 1 0 feet, 24 Volts (in continuous tone) Greater than 75 dBA minimum measured in a UL reverberant room at 1 0 feet, 24 Volts (in continuous tone) Electrical Specifications: 8200SR-WH, B200SR-IV External Supply Electrical Ratings External Supply 16 to 33 voe (VFWR) Voltage Standby Current: 500 µA maximum Alarm Current: 35 mA maximum SLC Electrical Ratings SLC Operating 15 to 32 voe Voltage: SLC Standby Current: Sound Output 300 µA maximum Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) Electrical Specifications: B200S-LF-WH, B200S-LF-IV External Supply Electrical Ratings External Supply 16 to 33 voe (VFWR) Voltage Standby Current: 550 µA maximum voe Alarm Current, High-volume setting 70 mA maximum @ 33.0 voe 90 mA maximum @ 24.0 voe 140 mA maximum @16.0 voe Alarm Current, Low-volume setting 15 mA maximum @ 33.0 voe 20 mA maximum @ 24.0 voe 25 mA maximum @ 16.0 voe SLC Electrical Ratings SLC Operating 15 to 32 voe Voltage: SLC Standby Current: Sound Output High Volume: Low Volume: 300 µA maximum (base only, refer to applicable sensor specification) Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) Greater than 75 dBA minimum measured in a UL reverberant room at 1 0 feet, 24 Volts (in continuous tone) Electrical Specifications: B200SR-LF-WH, B200SR-LF-IV External Supply Electrical Ratings External Supply 16 to 33 voe (VFWR) Voltage Standby Current: 1 mA maximum voe Alarm Current 65 mA maximum @ 33.0 voe 90 mA maximum @ 24.0 voe 125 mA maximum @16.0 voe SLC Electrical Ratings SLC Operating 15 to 32 voe Voltage: SLC Standby Current: Sound Output Refer to applicable sensor specification. Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) SPDS901-00 • 04/04/2018 • Page 3 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1653:0109 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, B501 B, 14506587-002, B501 BH, B501BHT, B401BH, B110LP, B110RLP, B110RLP750, B112LP, B114LP, B114LPBT, B116LP, B210LP, B501-BL, B501 -IV, *B501-WHITE, B300-6, B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, *model number, *electrical rating and UL label. Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. Formerly 7300-1209: 128 *Rev 04-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 202.2 OSI-RI-SK TECHNICAL SPECIFICATIONS PHYSICAL Dimensions (Detector): Height 6" (152.4 mm); Width 10" (254 mm); Depth 4.5" (114.3 mm) Dimensions (Reflector): Height 9.06" (230 mm); Width 7.87" (200 mm) Weight (Installed): 2.48 lbs (1.12 kg) Weight (Shipping): 3.91 lbs (1.77 kg) Wire Gauge for Terminals: 14 AWG (2.08 mm2) ELECTRICAL OSI-RI-SK Operating Voltage Range: Nominal: 24 VDC Minimum: 15 VDC Maximum: 32.0 VDC Maximum Standby Current: 13 mA @32VDC 14mA@24VDC 20 mA @15VDC Maximum Alarm Current (LED on): 22 mA @32 voe 15 mA @24 voe 22 mA @15 voe Maximum Devices per SLC Loop: The number of OSID-R devices are limited due to SLC current draw restrictions. Current draws listed above must be considered in coordination with any other devices on a circuit. In general, this limits the number of OSID-R detectors to up to 4 detectors per loop on a dedicated circuit on Silent Knight panels. Any non-beam devices, increased distances or higher gauge wiring on the circuit will decrease available current and total capacity of OSID-R detectors. Available panel current: • 6700: 1.00ma Normal operating current • 6808: 150ma Normal operating current • 6820: 150ma Normal operating current BEAMHKR Voltage Range: 15 to 32 V Maximum Current: 450 mA Max at 32 V Power Consumption: 7.7W@24V 15W @32 V RTS151KEY Voltage Range: 10.2 to 32 VDC Current Range: 9 mA Min to 11 mA Max ENVIRONMENTAL Operating Temperature: UL-Listed for use from 32°F to 100°F (0°C to 37.8°C). Honeywell Silent Knight 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.silentknight.com Application Temperature Range: -4°F to 131 °F (-20°C to +55°C) Humidity Range: 0 to 95% relative humidity, non-condensing OPERATIONAL Protection Range: 16 ft to 328 ft (5 m to 100 m) Adjustment Angle: 20 degrees vertical, 50 degrees horizontal Sensitivity Levels: Level 1 25%, Level 2 30%, Level 3 40%, Level 4 50% Test/Reset Features: Local alarm test switch, local alarm reset switch, Remote test and reset switch (compatible with RTS151 and RTS151KEY(-A) test stations), OSID-R test filter. Smoke Detector Spacing: On smooth ceilings, 30-60 feet between projected beams and not more than one-half that spacing between a projected beam and a sidewall. Other spacing may be used depending on the ceiling height, airflow characteristics, an d response requirements. See NFPA 72. AGENCY LISTINGS UL: S911 FM: PR449231 CSFM: 7260-0559:0515 PRODUCT LINE INFORMATION OSI-RI-SK: Intelligent imaging beam smoke detector including reflector OSP-002: Laser alignment tool OSP-004: Test filter, 10 pack RTS151: Remote test station RTS151KEY: Test and reset station with key lock, flush mount BEAMHKR: Heater kit for the reflector 6500-MMK: Multi-mountaccessoryforceiling or wall mounting with additional mounting adjustment SK-61052 I D I 07 /20 ©2020 Honeywell International Inc. Silent Knights is a registered trademark of Honeywell International Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico Honeywell ~SILENT" ~KNIGHf SK-DUCT-WAND DNRW Intelligent Photoelectric Duct Smoke Detectors The SK-DUCT-Wand DNRW use photoelectric technology to detect smoke and combustion particles present in air moving through an HVAC air handling system. The Silent Knight® SK-DUCT-W intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 -20.32 mis), temperatures of -4°F -158°F (-20°C - 70°C), and a humidity range of O -93 percent (non-condensing). An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble signal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Silent KnightSK-DUCT-W duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accessories. ACCESSORIES Silent Knight provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. FEATURES AND BENEFITS • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min -4,000 ft/min C0.5 mis -20.32 mis) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (- 40F -158°F, -20°C -70°C) and humidity • Cover tamper signal • Increased wiring space with a newly added 314" conduit knockout • Easily accessible code wheels on sensor head (included with SK-DUCT-W) • Clear cover for convenient visual inspection (SK-DUCT-W only) • Remote testing capability (0% -93% non-condensing) • Requires com line power only • Sampling tube installs from front or back of the detector with no tools required • Housing accommodates an addressable relay module, sold separately, for applications requiring a Form-C relay Honeywell ~Sn.ENT· ~KNIGHT LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 3242-0559:0518 Page 1 of 1 3242 --DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Model SK-DUCT-W Photoelectric duct analog smoke detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 24 Vdc In accordance with the listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as photoelectric duct analog smoke detector for use with System Sensor Model 8501 base (CSFM Listing 7300-1653:0109) and separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 08-01-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 Specifications, Duct Smoke Detector Accessories APA 151 Piezo Annunciator Voltage Regulated 24 VDC Operating Voltage 16 to 33 voe Maximum Alarm Current 30mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 1 Oto 93% non-condensing Wire Gauge 12to 18AWG Dimensions 4.6"H x 2.9"W x .45"0 MHR/MHW SpectrAlert® Advance Mini-Horns Voltage Sounder Current Draw Temperature Range Humidity Range Nominal Sounder Frequency Wire Gauge Dimensions Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 voe or FWR 22 mA RMS max. at 8 to 17.5 Volts DC 29 mA RMS max. at 16 to 33 Volts DC 0°C to 49°C (32°F to 120°F) 10 to 93% non-condensing 3 kHz 12 to 18 AWG 4.6"H x 2.9"W x 0.45 "0 RA 100ZJRA100ZA Remote Annunciator Voltage Range Maximum Alarm Current Dimensions RTS151 UL S4011 RA100Z UL S2522 Conventional System: 3.1 to 32 voe Intelligent System: 18 to 32 voe 10mA 4.6 "H x 2.8"W x 1.3"0 RTS151 KEY UL S2522 MHW ULS4011 RTS151 Remote Test Station Power Requirements Test Switch Reset Switch Alarm Response Time Temperature Range Relative Humidity Wire Gauge Dimensions Alarm LED: 2.8 to 32 voe, 12 mA max. Total Current: 105 mA max. 10 VA@32 voe 10 VA@32 voe 40 seconds max. -10°C to 60°C (14°F to 140°F) 95% non-condensing 14to 18AWG 4.B"H X 2.90"W X 1.4"0 RTS151 KEY Remote Test Station with Key Power Requirements Alarm Response Time Temperature Range Relative Humidity Wire Gauge Dimensions Power LED (Green): 14 to 35 voe, 12 mA max. Alarm LED (Red): 2.8 to 32 voe, 12 mA max. Total Current: 105 mA max. 40 seconds max. -10°C to 60°C (14°F to 140°F) 95% non-condensing 14to 18 AWG 4.6 "H x 2.75"W x 1.8"0 RTS2 and RTS2-AOS Multi-signaling Accessory Voltage Power Requirements Sounder Temperature Range Relative Humidity Wire Gauge 20 to 29 voe Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. 85 dBA at ten feet -10°C to 60°C (14°F to 140°F) 95% non-condensing 14to22AWG Dimensions 4.8"Wx5.3"H x 1.6"0 For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. APA151 UL S4011 RTS2-AOS UL S2522 MHR ULS4011 AOS ~SYSTEM '-~ SENSOR~ 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. HVDS20202 • 8/13 ~SYSTEM '-~ SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12-or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING ® LISTED S5512 S4011 <8> APPROVED FM approved except for ALERT models 3057383 I . 7125-1653:0504 7135-1653:0503 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 • 12/01/2017 • Page 3 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33Volts 8-17.5 Volts 16-33Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15-177 cd) 8-17.5 Volts 16-33Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 ~SYSTEM '-~ SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modem aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12-or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75 , 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units f I R E • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING @ LISTED S5512 54011 <8> APPROVED FM approved except for ALERT models 3057383, 3057072 -~ 7125-1653:0504 7135-1653:0503 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS865-05 • 2/22/2018 • Page 1 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33Volts 8-17.5 Volts 16-33Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 NIA 107 136 Non-Temporal High 43 47 54 95 NIA 121 155 Non-Temporal Low 29 32 54 110 NIA 148 179 3.1 KHz Temporal High 39 41 54 135 NIA 172 209 3.1 KHz Temporal Low 29 32 54 185 NIA 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd) 8-17.5 Volts 16-33Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVDS865-05 • 2/22/2018 • Page 3 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-1653:0504 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Page 1 of 2 System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-1653:0503 7135 --AUDIBLE DEVICES Page 1 of 2 System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mou~ted Back Boxes: Revision 08-21-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022