Loading...
HomeMy WebLinkAboutMS 16-05; 1284 PINE AVE; FINAL DRAINAGE STUDY; 2019-11-05FINAL DRAINAGE STUDY FOR PARCEL MAP MS16-05 1284 PINE AVENUE, CARLSBAD 92008 DWG 518-7A / GR201 9-0024 APN 205-020-57 In The CITY OF CARLSBAD, CA Prepared For 1284 PINE PARTNERS, LLC 1284 PINE AVENUE CARLSBAD, CALIFORNIA 92Ocr lemul NOVEMBER 5, 2019 MOD IODM William C. Hobbs L..- RCE 42265 W. C. HOBBS, CONSULTING ENGINEER 33892 COPPER LANTERN, UNIT A DANA POINT, CALIFORNIA 92629 951.660.9800 wchobbs@wwdb.org RECEIVED DEC 04 2019 LAND DEVELOPMENT ENGINEERING DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECALRE THAT I AM THE CIVIL ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT, AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS, SPECIFICATIONS AND TECHNICAL STUDIES BY THE CITY OF CARLSBAD IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS ENGINEER OF WORK OF MY RESPONSIBILITIES FOR PROJECT DESIGN. oss IQ' CiN NO. 42265 C I v % OF CP' RCE 42265 PURPOSE OF PROJECT The proposed project includes construction of a residential structure on a previously rough graded and city approved parcel recently split from a larger parcel. SITE LOCATION The site resides at 1284 Pine Avenue in the City of Carlsbad. A Vicinity map is attached herein as Figure 1 on the following page. DESCRIPTION OF WATERSHED The existing property (parcel 2 of parcel map 21580) is approximately 0.1741 acres, currently an undeveloped lot, however recently graded. There is currently no specific drainage system, and runoff flows westward as sheet flow and is discharged existing paver driveway and swale exiting onto Pine Avenue to the south Proposed development consists of a residential structure with permeable paver sidewalks and landscaping on the remainder of the site. Proposed drainage consists of roof drains that are collected and disposed into landscape area at the front or eastern end of the building; where it is allowed to infiltrate. Area drains are proposed There is no existing run on and there will be no post development run on of storm waters. Referring to the County of San Diego Hydrology Manual the following parameters were obtained regarding the site: 100 yr. - 6 hour Rainfall Event: 2.3 inches (adjusted) 100 yr. -24 hour Rainfall Event 4.1 inches Hydrologic Soil Group: B (based upon hydrology manual plates) Runoff Coefficient: C=0.25 for areas with 0% impervious cover and C=0.45 for areas of partial impervious cover (table 3-1) ---- two basin types analyzed in this study. 11 0 C DO VICINITY MAP NOT TO SCALE: THOMAS GUIDE COCA. PAGE 1106 F-5 METHODOLOGY Utilizing the rational method as outlined in the County of San Diego Hydrology Manual, the 100 year-6 hour storm event peak flows were calculated to drainage basin peak flows and corresponding drainage areas. A summary of the calculated peak flows follows in the chart titled Calculation Summary. In addition, on-site drainage pipes were sized utilizing Manning's equation. Inlet grates were analyzed using the weir and orifice equations. Calculations and corresponding documentation is provided in Appendix B. SUMMARY The 100 year peak flows for the parcel for the year storm indicated was calculated and is presented below for design purposes. Calculated 100 year peak flow, 0, in tables is cubic feet per second, CFS. CALCULATION SUMMARY Basin Dev Qi 00 Und Qi 00 Dev Ic Und Tc Parcel 0.204 cfs 0.153cfs 17.4 min. 12.6 mm. The parcel saw a slight increase of .05 cfs in the post development scenario. This is a negligible amount being added to the Pine Avenue stormwater collection swale on the north side of the Street. Conclusion It is our professional opinion that the additional flow of 0.05 cfs will have a negligible impact on the existing public storm drain system. APPENDIX A HYDROLOGY BASIN MAP(S) -- N F LECEND NOTE: TYPE "8" SO LS TYP. 0' 10' 40' I 20' SCALE: 1" 20' PROJECT DATA: DRAINAGE BASIN DATA: BASIN I.D. % IMP "C" (: D 0% 0.25 PROJECT ID. 829 SOUTH PACIFIC APN NO. : 150-356-18 ADDRESS: 829 SOUTH PACIFIC STREET OCEANSIDE CA 92054 AREA 0.174 AC BASIN LABEL EXISTING CONDITION iIYDROLOGY A F -- ------ - -------- -- ----- ------- ----, ---- ---- - - - --Ti - -- ---------- --- --- ------- --------- -- 11263 TW/10797 TF 11397 TW/11063 IF, 11330 TW/10797 IF 11333 T\'(N) 11263 lW(S) 11397 TW(S) 11263 TW(N)\ 10797 T,F DRAIN GUlLET r10900 IL 11263 lW(S) 10863 1F(N) 11063 IF(S) / ' ry MAX WALL, EXISTING Ln E WALL DGE'OT MIA FOOTING In 7 19' --- . ----------------6O RIGHT OF 'V TIO PVC PIPE 777 7 / CENTERLINE EXISTING TERMER (APP,) I 41O%4" / - 2329 -- EX. 8' SE LEGEND NOTE: TYPE "8" SOI LS TYP. ro 0' 10' DRAINAGE BASIN BOUNDARY PROJECT DATA: 20 SCALE: 1" 20' PROPERTY LINE PROJECT ID. 829 SOUTH PACIFIC ARN NO. :150-356-18 ADDRESS: 829 SOUTH PACIFIC STREET OCEANSIDE CA 92054 DRAINAGE BASIN DATA: BASIN I.D. % IMP "C" AREA 40.6% 0.45 0.174 AC 220 L.F. PLOW PATH & DIRECTION BASIN LABEL DEVELOPED CON D I TI ON HYD R OLOGY MA P APPENDIX B CALCULATIONS AND FIGURES RATIONAL METHOD PEAK FLOW CALCULATIONS Given the geographic coordinates of 33.162043° and -117.339504°, we determine: From the San Diego County Hydrology Manual "SOILS HYDROLOGIC GROUP MAP", the soils are identified as type "B" soils. From the San Diego County Hydrology Manual 'Table 3-1---RUNOFF COEFFICIENTS FOR URBAN AREAS", the runoff coefficients were determined to be C=0.25 for areas with 0% impervious cover and C=0.45 for areas under developed conditions---the two basin types analyzed in this study. From the San Diego County Hydrology Manual "FIGURE 3.1 --- INTENSITY DURATION DESIGN CHART TEMPLATE", the Intensity values are established for the 100 year storm. From the San Diego County Hydrology Manual Rainfall Isopluvial charts "100 YEAR RAINFALL EVENT 6-HOURS AND 24 HOURS", the rainfall events were established as: 100 year--6 hour precipitation is (P100-6) = 2.6 inches and the 100 year-24 hour precipitation is (P100-24) = 4.1 inches. Per SD County, P100-6 was adjusted to 2.3 Inches and used as the basis for this study. Utilizing the Rational Equation Q = CIA, the following flow rates on the next page can be calculated. Hydraulic Calculations/Documentation 1) Yard Drains (along drainage pipe) Calculation following indicate that a 4" drain pipe flowing full at 2% will carry 0.29 cfs. That is more that the developed condition for the entire project, so it will be assumed that the 4" pipe is adequate. A A ADcA&L I¼floD t4oLOi/• hr too ~jm = !,!he- c[co 4, !c1uAPtr t;. L.- i. —1 3 M110. iiILfiom_i AT z"/t L Z'Zo A9' 1AØ2 1: San Diego County Hydrology Manual Section: 3 Date: June 2003 Page: 6 of 26 Table 3-1 RUNOFF COEFFICIENTS FOR URBAN AREAS - Land Use I Runoff Coefficient "C" Soil Type Elements I % Permanent Open Space 0 0.20 0.25%/ 0.30 0.35 Residential, 1.0 DU/A or less 10 0.27 0.32 0.36 0.41 Residential, 2.0 DU/A or less 20 0.34 0.38 0.42 0.46 Residential, 2.9 DU/A or less 25 0.38 0.41 0.45 0.49 Residential, 4.3 DU/A or less 30 0.41 0.45 0.48 0.52 Residential, 7.3 DU/A or less 40 0.48 0.51 0.54 0.57 Residential, 10.9 DU/A or less 45 0.52 0.54 0.57 0.60 Residential, 14.5 DU/A or less 50 0.55 0.58 0.60 0.63 Residential, 24.0 DU/A or less 65 0.66 0.67 0.69 0.71 Residential, 43.0 DU/A or less 80 0.76 0.77 0.78 0.79 Neighborhood Commercial 80 0.76 0.77 0.78 0.79 General Commercial 85 0.80 0.80 0.81 0.82 Office Professional/Commercial 90 0.83 0.84 0.84 0.85 Limited Industrial 90 0.83 0.84 0.84 0.85 General Industrial 95 0.87 0.87 0.87 0.87 NRCS Elements Undisturbed Natural Terrain (Natural) Low Density Residential (LDR) Low Density Residential (LDR) Low Density Residential (LDR) Medium Density Residential (MDR) Medium Density Residential (MDR) Medium Density Residential (MDR) Medium Density Residential (MDR) High Density Residential (HDR) High Density Residential (HDR) Commercial/Industrial (N. Corn) Commercial/Industrial (G. Corn) Commercial/Industrial (O.P. Corn) Commercial/Industrial (Limited I.) The values associated with 0% impervious may be used for direct calculation of the runoff coefficient as described in Section 3.1.2 (representing the pervious runoff coefficient, Cp, for the soil type), or for areas that will remain undisturbed in perpetuity. Justification must be given that the area will remain natural forever (e.g., the area is located in Cleveland National Forest). DU/A = dwelling units per acre NRCS = National Resources Conservation Service 3-6 uiiiuuiniu iiiiiiiiii1111111111111111`1111111111111001111111111111111111111111111111 1111111111 Hill 11111111111111111111111111111111101 Mil 11 HIM HIM Ifflill II IIIIIIIIIllhI1IIIIII lull IIIII IIIIIIllIUhItIIIIliuIIIIIlIUhI IIIIIIIIIII !IIIIlIII1IOhIIIIIIllhIIIIIIItIIIl JIII ''IIIhIIIIi!i !!II1i!l1I!!!G 's••lI••••IIlIIIuIUI I'll IIiI IIIIIIIIIIII!1III IIIIIIIIIIuI;1 III 'UI IN IN IN I;!!!(IHhIIIInhIIIuaBill (I !!!1hJIIIIIIlIII II iri!IIiu1!lii II P till uuIIIli;Itlh:!iIII IllhIIIIIi!!iIIIh 1I IIIItIIII{'!IIIIUI!l IIIIUIIIIIIIIIII!ilh iIInIi!lllI1IIIiiI! IUIIIIIIIllIllflhi!iII aIluN•UuIllIUUuI .uu..u•.uIIIlIIuI ..a.....uuiulll ..0 • iu.••uuhuuuIII UII•.UU•IIIIuI,uI u ..ia. iii .uuuu ...Iu.1uIuIuIIIuII IUU 11 1111111111111 IIIuIIIuIIIlIJI uuuIIIuIIIu, uHIII .. gill luhuululllfl ulutlululllmhulll IltIlIlIflhll ui UU•U U•uIiiihih i,uii,1c111111 ..U...•IUIuIIuuU 11111511111 - ...n and urn. Pul ii huh, ul ii ..I...IIPI 1111111 HI U .u.uim. IIHIII iiiiii.. IUIUIIIIIIIIUII hiuiIlullHlihl••U i•uu•iiuiuiuui itiiiii IRS Nelson milli uHIM s iiiiiiiiiin. •u•uuiuuuuii.iiuii I IHIlIlIlUIl lIIIIIuIIlIIIIIII1 MANNING'S EQUATION FOR PIPE F Project: 11284 PINE AVENUE By: WCH Chk. By: jLocation: 11284 PINE AVENUE, CARLSBAD Date: 11/5/2019 Date: mdo version 12.8.00 Clear Data 0 Entry Cells INPUT Mannings Formula dl Q=(1 .486/n)ARh S1 R=A/P A=cross sectional area P=wetted perimeter S=slope of channel n=Manning's roughness coefficient lSolution to M Wetted Hydraulic Area,ft2 Perimeter, ft Radius, ft velocity I 0.09 1.05 0.08 I 3.34 D= winches d= 41inches n= 0.01 n= coeft 0= 0.0 degrees S=[ 0.02] slope in/in V=(1 .49/n) RhS1 Q=V x A n-values )w, cfs PVC PE (<9"dia) 0.01 0.015 0.29 1 PE (>12"dia) PE(9-1 2"dia) 0.02 0.017 CMP 0.025 ADS N12 0.012 HCMP 0.023 Conc 0.013 APPENDIX C WATERSHED INFORMATION County of San Diego Orange- Hydrology Manual 33*3(Y— ___ County Riverside County 61 \, Rainfall Isopluvials 33'15' 100 Year Rainfall Event 24 Hours OCEANSIDE — -, I ID ---.-.--------- IsopIuvial (inches) . - ° 61 -o s -- C) ENONI AS -. 3300 -- / _________ 3OO C) SOLANABEACF - /. ?( y SE) OE)NTY 50 - ----- - Q DEL MA C) Sb A I CD - -- di ANTE ASU 1.3 -' ______ — ____________ _____________________ - 32o45' ------ -.i--------- - -- 4 . .---- -.--- __________- - --------- 2 45 A DPW SID IMPERIAL ACH - - MeXfl 323O' S 32'30' Ell - 3 0 3Mjles County of San Diego Orange __________j__________ ________ __________ ____ Hydrology Manual County I Riverside County Rainfall Isopluvials 33 15 100 Year Rainfall Event 6 Hours 3315 _ ... 25 OCEANS!DE ....... .... Isopluvial (inches) Der ..: CARLSEAD ... ;••,• Cl ENCIN ._. / - , . ••..--. .. ,.•, 3300 -. _ ____________ ______ S3 *00' 0 SOLENA BEACI ________ / P(W j so coums ____________ . - - O DEL MA CD .....- - C / - 32 45 245' ,•-.•._.•. - - .. . . - ORON •" .' - ... ------- co J DP Sa1GIS GIS its IMPERCLACF . . , .,i ... ..------- - cos M e X 3230 3230 S ________________________ Ell __________________________ b 3 0 3MiIes County of San Diego Orange ____ _______ __________ ____________ ____ ______ Hydrology Manual --t. County l~ - - Riverside County - -- fl - . Soil Hydrologic Groups 3315-- . ___________ -33 d V, ffial . ,. - I gpnd F- I _.. - tt - r ISoil Groups rn- Elilili Group Al Group -0 - . -- ) ,.• - -_ II'j• . . 'i Group C - LJ C) - ENCIN -' I • - - :-<- r , ..'i & Group D - V Undetermined ___________ _______________ . - _____ Data Unavailable - 33 01 SONABF .. -'I' .. . --.•. - - DEL MAFik - -.- ( .• . . .a #1112 1 NIt !. '-... -- - V --. 1 o I -j 4* ,tflfiI!lI 32M5 - .- iss - -- - DPW jik, GISSflGIS \'L IMPERIAL M e x C 0 3230 3230 3O3Mes SOLANA BEAC - - :4 -A CARLS BAD ENCINITA 330 00' OCEANSID