Loading...
HomeMy WebLinkAboutCD 2019-0020; PARK HYATT AVIARA; FIRE LANE ACCESS RECOMMENDATIONS FOR CONCRETE SURFACE AREAS; 2019-12-19A14 T RECORD COPY - Initial Date Leighton Consulting, Inc. A LEIGHTON GROUP COMPANY December 19, 2019 Project No. 12493.001 To: Xenia Hotels & Resort, Inc. 200 S. Orange Ave. Suite 2700 Orlando, FL 32801 Attention: Mr. Stephen Long Subject: Fire Lane Access Recommendations, Proposed Renovations to the Park Hyatt Aviara Resort, Carlsbad, California References: Leighton Consulting, 2019, Geotechnical Investigation Report, Exterior Renovations, Park Hyatt Aviara Resort Golf Club & Spa, Carlsbad, California, ProjectNo. 12493.001, dated October 23, 2019. As background, Leighton Consulting, Inc. (Leighton) has performed a geótechnical investigation for improvements at the Park Hyatt Aviara Resort Golf Club & Spa (Hyatt Aviara) in Carlsbad, California (Leighton, 2019). Improvements include new areas of fire lane access that could be subjected to a 75,000-pound loading. Based on our investigation and loading requirements above, we recommend a "Grasspave2" product be used for the proposed fire lane areas. This product consists of a HDPE plastic confinement rings that can be infilled with clean washed concrete sand for supporting grass sod turf or a synthetic turf material (Nutmeg Ultra), as specified by the Landscape Architect. The "Grasspave2" section should be underlain by a 12-inch Class 2 Permeable Base section, over a compacted subgrade. The upper 12 inches of subgrade and the Class 2 Permeable material should be compacted to a minimum of 95 percent relative compaction (ASTM D 1557). If a synthetic turf material is being proposed, the "Grasspave2" product should be underlain by a filter fabric (Mirafi 140N) and the clean washed concrete sand infill should be mechanically densified and/or jetted into place for compaction in accordance with the manufactures guidelines. 3934 Murphy Canyon Road, Sue B205 • San Diego, CA 92123-4425 858.569.6914 • Fax 858.292.0771 • www.leightongroup.com. 12493.001 The findings and conclusions contained within this letter are based on data obtained from limited number of observations, site visits, soil excavations, samples, and tests. Such information is, by necessity, incomplete. The nature of many sites is such that differing soil or geologic conditions can be present* within small distances and under varying climatic conditions. Changes in subsurface conditions can and do occur over time. In addition, changes made during design development and construction should be reviewed by Leighton to determine if recommendations are still applicable. If you have any questions regarding our letter, please do not hesitate to contact this office. We appreciate this opportunity to be of service. Respectfully submitted, D. LEIGHTON CONSULTING, INC. . FED 0• SSi ENGINEERIN ExpJZ No. 45283 46 o 06. Joi William D. Olson, RCE 45283 Mike Jensen,.CEG 2457 Associate Engineer . Associate Geologist Distribution (1) Digital Copy ) 2 Leighton