Loading...
HomeMy WebLinkAboutPD 2019-0015; CARLSBAD INN MITIGATION; RESPONSE TO CITY COMMENTS, ON PLANS DATED 7/23/19; 2019-07-23SHORING DESIGN GROUP' CORD copy J ( L' [ initial jute July 23, 2019 - Mr. Mark Elliott Elliott Drilling Services, Inc. 1342 Barham Drive San Marcos, CA 92078 REcr; 'if 'JUL 31 2tS Office (760) 722-1400 Fax (760) 722-1404 Re: Carlsbad Inn Carlsbad, California LAND DEVL....frNT .EN GIN"EL JOB #19-109 Subject: Response to City Comments, on Plans Dated 7/31/2019 Dear Mr. Elliott: Shoring Design Group is in receipt of the plan review comments prepared by Michael Baker International, on behalf of the City of Carlsbad, regarding the above referenced project. In response, Shoring Design Group (SDG) offers the following, responses: Response to Shop Drawing Review All internally braced soldier beams (supporting adjacent building surcharge), limit lateral deflection to 0.25" along the top of pile (see -calculations). All remaining beams (cantilevered and not supporting building surcharge), are designed for a maximum deflection of 1-inch. All soldier beams, supporting adjacent building surcharge, are internally braced and limit lateral deflection to 0.25" along the top (see response to item 1 above). All internally braced soldier beams have been re-designed to the at-rest pressure provided by the geotechnical engineer of record. The adjacent building & parking garage will not be adversely affected by the loads imposed by the temporary strut supports. Attached, please find the requested analysis that demonstrate threshold stresses below service requirements. Response to Comments on Plans Response to comments on sheet 10 [New sheet 8]: Please see updated title-block information & sheet count. As requested, please see the updated sheet range within declaration. The temporary cut slope for the pool removal & basement grade will vary depending on the selected grader & demo contractor. The exact extents of the sloping are to be determined ,by the awarded contractor & shall be conducted in conformance with CAL—OSHA & geotechnical requirements, as noted on (new) sheets SH10 & SH11. Please see updated street call out "Carlsbad Village Drive". Response to Comments on Plans (Continued) Response to comments on sheet 19 [New sheet 17]: Please see updated "General Note" #13, with the corrected spelling typo. Please see added "General Notes" #19-20 & updated "Monitoring" notes for the requested information. Should you have any additional questions or comments regarding this matter, please advise. Sincerely, SHORING DESIGN GROUP, P. CD C 80503 &p. 3/31/21 J 1* '- cgv/) Roy P. Reed, P.E. Project Engineer Enclosed: Existing Wall Finite Element Analysis Shoring Design Group Carlsbad Inn 7755 Via Francesco #1 Eng: RPR Sheet _of_ San Diego, CA 92129 Date: 7/2212019 CMU Wall Properties Typical Strut Reaction (Max. Load)' CMU Wall Properties H := 10-ft = Maximum height of retained cmu wall tw := 12-in = Masonry wall thickness b:= 1.ft = Width of cmu (for-analysis /.ft) fm := 2000-psi = Masonry wall compressive strength Em := 900 -fm' = Modulus of elasticity u:= 0.20 = Poisson's ratio for fully grouted cmu 150 .psl = Modulus of rupture Em = 259200000.psf - Units for finite analysis consistency WALL STRESS OUTPUT (SEE LISA FINITE ANALYSIS) Mu := 1087-lb-ft = Maximum bending moment per analysis Vu := 9774. lb . = Maximum shear per analysis Nominal Cracking Moment Nominal Shear in Masonry 2. r (Mu '1 Mcr: 6 Vm:14 _ 1.75•1 Vu— .dvjl•tw•b•Vlfm'•Psi 0.90Mcr = 3240ftlb O.lOVm = 16978.8 lb Wall cracking Et shear not exceeded ---> Okay CMU Properties.xmcdz * Shoring Design Group Carlsbad Inn 7755 Via Francesco #1 Eng: RPR Sheet of San Diego, CA 92129 Date: 7/22/2019 CMU Wall Properties "Strut Reaction at Elevator Shaft" CMU Wall Properties H := 10-ft = Maximum height of retained cmu wall tw:= 12-in = Masonry wall thickness b:= 1•ft = Width of cmu (for analysis / ft) fm := 2000- psi = Masonry wall compressive strength Em := 900 .fm' = Modulus of elasticity u:= 0.20 = Poisson's ratio for fully grouted cmu f r := 150-psi = Modulus of rupture Em = 259200000.psf - Units for finite analysis consistency WALL STRESS OUTPUT (SEE LISA FINITE ANALYSIS) Mu := 3081-lb-ft = Maximum bending moment per analysis Vu := 6708. lb = Maximum shear per analysis Nominal Cracking Moment Nominal Shear in Masonry fr.b.tw 2 r ( Mu 11 ____ M := . V := 4 - 1.75.1 I •tw.b• fm'.psi cr 6 m Vu.dvJ' O.9OMcr = 3240ft1b O.lOVm = 13683.6 lb Wall cracking Et shear, not exceeded --- > Okay CMU Properties - Max Span.xmcdz