Loading...
HomeMy WebLinkAboutSDP 15-10; CARLSBAD OAKS NORTH BUSINESS PARK LOT 13; SOIL NAIL WALL PLAN REVIEW AND GLOBAL STABILITY ANALYSIS; 2016-01-18GEO CON INCORPORATED GEOTECHNFcAL 1 ENVIRONMEN,TA:L • MATERIALS Project No. 06442-32-20 January 18, 2016 SR22 Carlsbad Oaks Distribution, LLC % SR Commercial 127 Lomas Santa Fe Drive Solana Beach, California 92075 Attention: Mr. Adam Robinson Subject: SOIL NAIL WALL PLAN REVIEW AND GLOBAL STABILITY ANALYSIS CARLSBAD OAKS NORTH BUSINESS PARK - LOT 13 CARLSBAD, CALIFORNIA References: 1. Permanent Soil Nail Walls, Tier 1, Tier 2, Tier 3-1 & Tier 3-2, Carlsbad Oaks Lot 13, Carlsbad, California, prepared by Drill Tech Drilling and Shoring, Inc., PDF copy received October 15, 2015. 2. Update Geotechnical Report, Carlsbad Qaks North Business Park - Lot 13, Carlsbad, California, prepared by Geocon Incorporated, dated March 18, 2015. Dear Mr. Robinson: In accordance with your request, we have reviewed the retaining wall plans for the Carlsbad Oaks North Business Park - Lot 13 project. The purpose of our review was to check that the plan and details have been prepared in substantial conformance with the recommendations presented in the referenced project geotechnical report. In addition, we performed a global slope stability analysis for the proposed soil nail wall. Based on our review, it is our opinion that the wall plan and details have been prepared in substantial conformance with the recommendations presented in Reference No. 2. We utilized the computer program GeoStudio 2007 distributed by Geo-Slope International to perform the slope stability analysis. This program uses conventional slope stability equations and a two- dimensional limit-equilibrium method to calculate the factor of safety against deep-seated failure. For our analysis, Spencer's Method with a circular failure mode was used. Spencer's Method satisfies both moment and force equilibrium. We used the shear strength parameters presented in Reference No. 2. These shear strength values are shown on Figures 1 and 2 (attached herein). We used Special Publication 117A guidelines adopted in 2008 by the California Geologic Survey (CGS) for evaluating static and seismic slope stability. An equivalent site acceleration, kEQ, of 0.15g was used to perform the seismic slope stability analysis. Based on our slope stability analyses, the proposed soil nail retaining wall exhibits a minimum factor of safety of at least 1.5 and 1.0 for static and seismic loading, respectively, and is considered grossly 6960 Flanders Drive 0 SOn DiegO, California 921212974 0 Telephone 85.558.6900 U Fax 858.558.6159 (e-mail) (e-mail) (e-mail) Emilio Alvarado RCE 66915 Attachments: Figures 1 and 2. EA:DBE:dmc Addressee Excel Engineering Attention4 Mr. Andrew Van Loy TFW Construction Attention: Mr. Ted Weeks IV stable as designed. This opinion assumes that the recommendations presented in the referenced report are implemented during construction. The results of the slope stability analyses are presented in Figures 1 and 2. Our plan review was limited to geotechnical aspects of project development and did not include the review of other details on the referenced plan. Geocon Incorporated has no opinion regarding other details found on the referenced plan, structural, civil, or otherwise, that do not directly pertain to geotechnical aspects of site development. If you have any questions regarding this correspondence, or if we may be of further service, please contact the undersigned at your convenience. Very truly yours, GEOCON INCORPORATED David 4B. )t CEG 1860 - DAVID B. EVANS NO. 1860 CERTIFIED ENGINEERING GEOLOGIST, Project No. 06442-32-20 -2- January 18, 2016