HomeMy WebLinkAboutCUP 06-11B; PACIFIC RIDGE SCHOOL EXPANSION; GEOTECHNICAL UPDATE LETTER; 2013-05-144 Leighton and Associates, Inc. A LEIGHTON GROUP COMPANY (Lcfi&l cxr 1L1, APR 152O1S LA""" DEVELOPMENT ENGINEERING May 14, 2013 Project No. 971009-068 To: Pacific Ridge School 6269 El Fuerte Street Carlsbad, California 92009 Attention: Mr. Bob Buscher Subject: Geotechnical Update Letter, Pacific Ridge School Expansion, Bressi Ranch, PA-13, California Introduction In accordance with your request, this letter has been prepared to update our geotechnical report for Pacific Ridge School Expansion located in Bressi Ranch, Carlsbad, California (Figure 1). The purpose of our geotechnical update was to observe and evaluate the existing geotechnical conditions of the subject site, review the project geotechnical reports, update geotechnical recommendations for the seismic design parameters per 2010 California Building Code, provide updated geotechnical map and cross-sections, and provide appropriate conclusions and additional recommendations for the proposed development of the site. We understand that the Pacific Ridge School Expansion will include construction of a three new school buildings including middle school building, a performing arts building, and theater building. We also anticipate that the proposed development will include associated improvements such as concrete flatwork, underground utilities, landscaping, etc. Existing Site Conditions Currently, the Pacific Ridge expansion area is occupied by 4 modular administration and classroom temporary buildings with associated landscaping and a large lawn/sports field area to the north. The proposed improvements are underlain by the Santiago Formation and with artificial fills associated with original rough and fine grading at the site and existing site improvements (see Plate 1). 3934 Murphy Canyon Road, Suite B205 • San Diego, CA 92123-4425 858.292.8030 • Fax 858.292.0771 • www.lelghtongroup.com 971009-068 Conclusions and Recommendations Based on our review of the project geotechnical report (Leighton, 2008), the geotechnical conditions of the subject site have not significantly changed since the completion of our geotechnical report in 2008. Therefore, it is our professional opinion that the conclusions and recommendations in the referenced geotechnical report are still considered applicable and should be adhered to during the design and construction phase of this project unless superseded by recommendations presented below. The following recommendations should supersede those presented in our referenced reports (which is attached as Appendix A): Undocumented landscaping fill should be removed to competent material throughout the site. The bottom of the removal should be processed (i.e., scarified a minimum 8 inches, moisture-conditioned to 2 percent above optimum moisture- content) and recompacted to a minimum 90 percent relative compaction (based on ASTM Test Method D1557). Expansion and sulfate testing should be performed on finish grade soils are in accordance with referenced geotechnical report. Based on the proposed building locations (Hoffman, 2013) and our review of the as-graded conditions, fills on the order of approximately 2 to 75 feet will underlie the proposed buildings. As a result, significant fill thickness differentials will be present below the proposed buildings will need to be mitigated (see Figure 2). Mitigation measures include utilizing overexcavation of the shallow fill area in order to reduce the fill differential thickness or a deep foundation system (i.e. piles or caissons). Recommendations to mitigate differential fill thickness will be provided at a later date. The west side of the proposed theater and performing arts buildings will be underlain by relatively thin thickness of fill soils (on the order of 3 feet). As a result, cut/fill transition conditions may be present beneath the proposed buildings that may need to be mitigated by the overexcavation of the shallow fill and the formational material below. To mitigate cut to fill transition an overexcavation of 6 feet below finished grade or 4 feet below the foundations, whichever is deeper, is recommended. The excavations should extend laterally at least 5 feet outside building foundations. It should be noted that excavations for the overexcavation at the basement area in the theater will extend up to 17 feet west of building and into existing improvements (i.e. utilities). Shoring may be required to perform theater building overexcavations in this area. The limits and depths of overexcavation are provided on the attached updated geotechnical map and the geological cross-sections (see Plate I and Figure 2). -2- 4 Leighton 971009-068 The new storm drain planned between the new proposed buildings will likely make it extremely difficult to perform the recommended building pad overexcavations and excavations for the proposed theater basement. Therefore, we recommend that pad overexcavations and remedial grading for the proposed buildings adjacent to new storm be performed prior to or during storm drain construction. The following updated seismic design parameters, determined in accordance with the 2010 CBC and the USGS Ground Motion Parameter Calculator (Version 5.1.0), should be used in the design of the proposed improvements. CBC (2010) Seismic Code - Parameters for the Site Description Values CBC Reference Site Class D Table 1613.5.2 Short Period Spectral Acceleration S8 1.100 Figure 1613.5(3) 1-Second Period Spectral Acceleration S1 0.417 Figure 1613.5(4) Short Period Site Coefficient F8 1.06 Table 1613.5.3(1) 1-Second Period Site Coefficient F 1.583 Table 1613.5.3(2) Adjusted Short Period Spectral SMS 1.166 Equation 16-36 Acceleration Adjusted 1-Second Period Acceleration SMI 0.659 Equation 16-37 Design Short Period Spectral Response SDS 0.777 Equation 16-38 Parameter Design 1-Second Period Spectral SDI 0.440 Equation 16-39 Response Parameter Based on our review, the footings for the proposed buildings will be founded in competent fill material. Footings founded in compacted fill may be designed for a maximum allowable bearing pressure of 2,500 psf and should extend a minimum of 24 inches beneath lowest adjacent finish grade. To account for potential redistribution of forces during a seismic event, basement walls should also be checked considering an additional uniform seismic pressure distribution equal to 8 H psf, where H equals the overall retained height in feet. -3- Leighton 971009-068 Leighton should observe and test all fill placement during grading and observe footing excavations prior to concrete placement to confirm that the soil conditions are as anticipated. The conclusions and recommendations provided in this update letter are based on as- graded subsurface conditions observed during the previous site grading. The interpolated subsurface conditions should be checked in the field during construction. Construction observation of all onsite excavations and field density testing of all compacted fill should be performed by a representative of this office. All footing excavations should be reviewed by this office prior to placing steel or concrete. If you have any questions regarding this letter, please contact this office. We appreciate this opportunity to be of service. Respectfully submitted, LEIGHTON AND ASSOCIATES, INC. cc E%P- s;t ENGINEERING xp. IT1U1 LO Mike D. Jensen, CEG 2457 William D. Olson, RCE 45283 Project Geologist Associate Engineer Attachments: Appendix A - References Figure 1 - Site Location Map Figure 2— Cross-Section A-A' and B-B' Plate I - Geotechnical Map Distribution: (2) Addressee it -4- Leighton ? U' ii ft - ft j Approximate Site Boundary -1i or J C tit w Ak lie vie ft ft ' 4k : N ft/ ft4( / \V, (Jk ftft J5 ' 0 2,000 4,000 4 Feet I t i Project: 971009-068 Eng/Geol: WDO/MDJ SITE LOCATION MAP Figure 1 Scale: 1 = 2,000' Date: May, 2013 Pacific Ridge School Expansion Base Map; ESRI Resources 2013 Bressi Ranch PA-13 Thematic Into: Leighton mmurpy(mmurpfly) Carlsbad, California Leighton Mao Saved as Vrafttiod97100968\GIS)of 2013-05-14\Flsorel mod on 5114r201311:03:41 Mi 971009-069 I Appendix A References California Building Standards Commission (CBSC), 2010, California Building Code (CBC) Hoffman Planning, 2013, Preliminary Grading Plans, Sheets C-4 and C-5, Pacific Ridge School, Carlsbad, California Leighton and Associates, Inc., 1997, Preliminary Geotechnical Investigation, Bressi Ranch, Carlsbad, California, Project No. 4971009-002, dated July 29, 1997. -, 2001, Supplemental Geotechnical Investigation for Mass Grading, Bressi Ranch, Carlsbad, California, Project No. 971009-0015, dated March 14, 2001. 2004a, Deep Fill Area Settlement Monitoring Recommendations, Bressi Ranch, Carlsbad, California, Project No. 971009-014, dated February 13, 2004, revised February 16, 2004. -, 2004b, As-Graded Report of Mass Grading, Planning Areas PA-13 and PA-14, and a Portion of PA-15, Carlsbad Tract No. 00-06, Bressi Ranch, Carlsbad, California, Project No. 971009-014, dated September 17, 2004. -, 2006b, Preliminary Geotechnical Conclusions and Recommendations Concerning the Proposed Right-Turn Lane on the West Side of El Fuerte Street, Bressi Ranch Planning Area PA-13, Carlsbad, California, Project No. 971009-044, dated September 27, 2006. -, 2006c, Geotechnical Response to City of Carlsbad Review Comments and Addendum Recommendations for the Proposed Development of the Pacific Ridge Private School, Parcels 2 through 4 of Bressi Ranch Planning Area PA-13, Carlsbad, California, Project No. 971009-044, dated November 3, 2006. -, 2007, Final As-Graded Report of Rough, Fine, and Post Grading, Parcels 2 through 4,Planning Areas PA-13, Bressi Ranch, Carlsbad, California, Project No. 971009-049, dated October 30, 2007. -, 2008a, Geotechnical Update Study, Permanent Campus Facilities and Campus Expansion, Carlsbad, California, Project No. 971009-053, dated July 10, 2008. -, 2008b, Geotechnical Evaluation of Water Intrusion and Soil Moisture Beneath Temporary Building, Pacific Ridge School, Carlsbad, California, Project No. 971009- 056, dated November 8, 2008. -5-