Loading...
HomeMy WebLinkAboutPS 2019-0109; WR KITCHEN & BAR; Sign Permits/Programs (PS){'city of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov ,:,G\}:JDl '1 -02-14 PLANNING APPLICATION #'PS2-01~-0\o:, REC'D BY-4io""-~,........---------- DATE 10%;;4,;; SIGN FEE1___.$-'2-7~• t10 _________ _ SIGN PROGRAM FEE ----------RECEIPT NO. _s:Jo .......... Y ..... Y .... h..._ _______ _ NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: _w_R_K_1r_c_H_E_N_&_B_A_R ____________________ _ Address of Project: ____ 2_66_8_G_A_TE_W_A_Y_RO_A_D __ ,_#_1_70 __ ,_C_A_R_LS_B_A_D __________ _ Assessor Parcel Number: ------------------------ Related Planning Case Number(S): ____________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) (b) Commercial (e) (c) Office/Industrial (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA 0) Produce Stand (k) Nursery (I) P-U/OS Zone Yes □ No □ Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes, o/ease comolete information on oage 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0 SIGN ORDINANCE: Yes O No O COASTAL ZONE: Yes O No 0 P-11 Page 1 of 4 No □ No □ Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No □ Date ------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** (.J '-•" 'I 6-~ '(1 Wall A,B,C THREE (3) 2. 'l, S' t;I 'V J '-tL,1,tr·. --••-· ..,,-_,,4 Suspended/Projecting '21.13~ ,, ,0 Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner 1 I ~ g. cJ. !.J-y 7lffl J.+'-~ Interim I **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of4 Rev. 02/28/18 , SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I l I P/L : Sjpt Dis~ce Requirement Show building/s I I . : I i I : I ~----I Show setbacks from all curbs --- I . I ' : I I I Show all property lines I P/L ! I I :/ I curb line i . : . ----------~--- • • Sight Visibility I Street N ame(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: ~2-9~5P~------sq. ft. Total Building Street Frontage: 204' -2" linear ft. Total Signage Allowance: 234·8 sq. ft. Existing Signage (sq. ft.): o sq. ft. Remaining Sign Allowance at Present: 234.8 ,sq. ft. Proposed Signage (sq. ft.): 97-5 sq. ft. Remaining Sign Allowance After Proposed Sign: 137.3 sq. ft. VILLAGE REVIEW AREA Total Signable Area: _________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 PROPERTY OWNER SHEA PROPERTIES APPLICANT ARCHITECTURAL DESIGN & SIGNS, INC NAME PRINT OR TYPE NAME PRINT OR TYPE MICHAEL LAWSON BARBARA COHEN MAILING ADDRESS MAILING ADDRESS 130 VANTIS, # 200, ALISO VIEJO, CA 92656 1160 RAILROAD STREET, CORONA, CA 92882, CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE I CERTIF ANDT T ISTR MY K--.__r,.,_ HAT I AM THE LEGAL OWNER L THE ABOVE INFORMATION D ORRECT TO THE BEST OF OGE. DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 714.906.2029 I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFOR TION IS TRUE AND CORRECT TO THE B OF Y NOWLEDGE. DA TE 09-25-09 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~ , Date: 10,6-,-. /1"', ✓ I . P-11 Page4 of4 Rev. 02/28/18 Shea Propcnie£ NO LABELS, PLAQUES OR STICKERS MAY BE AFFIXED TO THE SIGN WHICH ARE VISIBLE TO THE PUBLIC UNLESS REQUIRED BY COOE. file path: 6 \ADS Draw1ngs\Wood Ranch BBm & 6rill\WR Carslbad\31237\J • per11it\2 • emmr 11guge D Conceptual Package 0 Permit Package D Production Package REALITY BEGINS WITH VISION Pre pa red for: BY WOOD RANCH Project Address: 2668 Gateway Rd. Suite 170 Carlsbad, CA 92009 From: BARBARA COHEN cell: 714.906.2029 email: bcohen@od-s.com COLOR DISCLAIMER From: MILTON SOLOMON cell: 949.678.2878 email : msolomon@od-s.com SIGNAGE C)APPROVED ~) APPROVED AS NOTED ( ) RESUBMIT THE DESIGN TEAM HAS REVIEWED YOUR SUBMITTAL OF SIGNAGE DESIGN PLANS FOR SPACE ____ AND FINDS THEM IN SUBSTANTIAL CONFORMANCE WITH THE TENANT DESIGN CRITERIA. THIS APPROVAL IS FOR DESIGN AND MATERIALS ONLY. ANY AND AU ADDITIONAL PERMITS MUST BE OBTAINED SEPARATELY. CONTACT THE LANDLORD'S REPRESENTATIVE TO REVIEW THE MANNER AND ACCEPT ABILITY OF ATTACHMENT OF THISITHESE SIGN(S). Date: 10/25/19 By:Michael Lawson Scope of Work: SIGN TYPE SIGN NUMBER ILLUM DIMENSIONS Halo-Illuminated Channel Letters -y 4' -6" X 6' -3" Halo-Illuminated Channel Letters -1l 4'-4" X 6'-3" Holo-llluminoted Channel Letters -y 4' -4" X 6' -3" I Temporary Bonner N ]'-6" X 4'-0" Client Name (Please Print) ________ _ Date _/ __ / __ Due lo lhe fim11a1~11 ti Nskt11 mmrs a,d Ill 11la1,e 11ms1s1m11s 11,anm i~1lay MODnm a,d 1n1ters. 1h1 ctltrs 11• ma, rm scrm 1111 ,,,,, ma111th a !Ital~ acmate 111rai1ct11111 tie acttal 1raiacl We stnve 11 ■ake '" c1ltrs as acc,rale as 11ss1lle. l1t scrm 11i 1natei ,mges are 11t11ied as 11uide 11~ ui sl1uld 111 be re11rdei as ais1l1telr ctrrtel Site miihm aal m,11 h1lt111 ca als1 alltct law tie 111i,ct a,,urs (1 t LIO itff1111t fler11cu1 hit Matml IJ!IL Bad fit Na~fil Face I rt) We reco■■e■• lht yo■ ,e.■est a color sH1ple as CIIYI (C111. llaguta Y1l~wa1I Blackl are the colers mi ,a lie 1nat,ng ,~ms. whereas R681Rd. Grm anl 81111 are tie caltrs mi ly scrm ,~,1a,s sach as 1oar■1n1ttr far ti11 rmu a.I lue t1,ana1rans iolraimi by hpt Iii tanllS ~11,..HL Lie ail1rs 11 ,,., scrm II a ,n,t ■II Ht wct11 ■atci ti, fi■ttlei ,rid,ct Client Name [S1gna1ure) ________________ _ If 1o■ wet1• like to see a sa-,le ti a■y colot please !!•■est a■ act■al sa■pte lro■ yo■r Sales,erneor l'Jtject Maea,er. WITHOUT A SIGNED COLOR SAMPII. AO/S COMPANIES. ITS VENDORS AND AFFILIATES ARE NOT RESPONStBU FOR DIFFERENCES. REAL OR PERCEIVED, BETWEEN THE WAY YOUR PRODUCT APPEARS ON SCREEN OR PAPER ANO THE FINAL PRODUCT. PlfASE INITIAL All PAGES AD/S Drawing #30237 Rev. #06 (PS) Rev. Date, 10-24-19 Pages, 12 (Including Cover Sheet) QTY SQ FT 1 22.5 1 21.0 1 21.0 30.0 D Approved D Approved as Noted D Revise & Resubmit D Rejected Shea Properties. KITCHEN & BAR • BY WOOD RANCH KITCHEN & BAR BY WO O D RANCH KITCHEN & BAR - TOTAL BUILDING LINEAR FOOTAGE = 204'-2" GATEWAY ROAD NORTH CD SITE PLAN SCALE: 1/32' = l' · o• ffl~ 1160 Railroad St. ■ Sign age+ Fabrication Client: Project: Revisions: Project No: 30237-R06 (PS) Corona, CA 92882 ■Display s + Fixtures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad \ This is an original unpublished drawing created by AO/S Inc. It is T 800.862.3202 _4_ Rl 10.21.19-dimensions odded 10 show spacing between line, of copy Date: 2019-08-20 MS/JI/RT submitted loryour personal use in conjunction with a project being F95l .278.0681 ■L ighting+ Maintenance c/o Wood Ranch USA Inc. Caporale Offices 2668 Gateway Rd. Suite 170 _5 0 RI 10.23.19 -Sign B updored lo holo-illuminolion planned lor rou by AO/S Inc. It is not to be shown to anyone outside ■ ■ ■ www.ad-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your organizalion, nor is it to be used, reproduced. copied or Sign Trpe: Site Plan Westlake Village, CA 91361 _L RI 10.24.19-Sign A, olum pone! revised loorchirecturol element exhibited in any fashion without written permission lrom AO/S Inc. lile path 6:\AOS Orawings\Wood Ranch 880 & Grill\WR Carslbad\30137\J • pmrit\1 · exteriorsignage Sheet No: SPl.00 1 ol 11 COLOR SPECIFICATIONS: Pl: ■ Matthews Paint lo match Pantone PMS 7623 C P2: ■ Matthews Paint lo match Pantone PMS 7709 C P3: ■ Matthews Paint lo match Sherwin Williams SW 7068 •Griule Gray' P4: □ Matthews Paint SVOC 1304SP "White• Area of sign 0 face & returns 1 4'-4" 22.5 sq. ft. 0 face & returns ----------------------------·-------- I I 6'-3" \ I 1/8' ALUMINUM ---------- WALL STUD------------ 2 1/2" 11/2" .040" FABRICATED ALUMINUM RETURN ------~ Sha Properties. NO LAIIELS, PLAQ\JES OR STICKERS MAY BE AFFIXED TD TliE SIGN WHICH ARE VISIBLE TO TliE PUBLIC UNLESS REQUIRED BY CODE. .060' FABRICATED ALUMINUM FACE ---- NON-CORROSIVE 1/4' DIA. RIVNUT & ----4----c.:cl==:l THREADED ROD • NUT & WASHER FROM BACKSIDE -2• NON-CORROSIVE SPACER MIN. FOUR (4) PER LITTER .187" THICK CLEAR LEXAN SACK _____ __jl!----11 LIQUID TIGHT CONNNECTOR --------i~--,,l~J}:Jr.lI.lI.\! POWER CABLE THRU 1/2' DIA. FLEXIBLE-----!!---- METALLIC CONDUIT TO POWER SUPPLY AS REQ'D 12V POWER SUPPLY --- LOCATED IN RACEWAY BEHIND WALL LED STRIP.LIGHTING DOUBLE-STICK TAPED AND SCREWED TO LITTER BACK MIN. (2) 1/4" DIA. WEEP HOLES PER LITTER 2'-6" toll x 2 1/2 " deep halo-illuminated channel letters pin-mounted 1 1/2' from 1/a" aluminum architectural feature Internally illuminated with Agilight SignRayz 4500K LEO modules Architectural Feature: 1/a " thick aluminum panel flush mounted to building exterior wall surface *NOTE: not part of signage 8 ¾" toll x 2 1/2" thick aluminum fabricated sign panel w/ routed copy backed with 1/ a• thick white (7328) acrylic Internally illuminated with Agilight SignRayz 4500K LEO modules located around interior perimeter of panel 0 all exposed surfaces PLYWOOD BACKING REQUIREMENT\ FOR ELECTRICAL ILLUMl~ATION ttiMAff [lKIIICAI KlSSI lOOJM lO .. Pt(M!lO l'fOfl{[lS. • tl(DOfiD amm 'KIHJllwt£D•lllblSUOJ.6'0IJlltltflUft\[t:ilOOl!M l~rf001tf0fOil!ISW.I..Ul'II NOTE: nuSPEllUSIOllifSS-~OlllllW.Wl!lllil»iltl,IIOflKf:tt'JMl'l'~tl!l6 1U Tf.U6KIRMEMl!Yfl~11'.lWUSIJffl.lfSS!WilE: 16ft)6RDllNl'lf'-illl•1Mf!lml!O IUSl9r'i!<J.YI: -OED!CAfEOIIA.'t010lCUl1 -li!tEEWlll:5 llllE,!UUTUl.l£1lOlll"J 'MtfSllE .WM!l!Ui[f 12&1.. JlnttHOP,tlWtE ILSOMOH 6l,iJ6f [f'MlE~tllU#.:ll{OffllflHl6ntC1tl.~ & liM.blii: ASrU IIClillCU llC 6lOliliD W"JE WISI ll COO'llt:DJS Nll>60 FIIM !'!If SIGN JO Tl!E '1NHllilt:>6IOOICl'IUS.. .'!OlU6ESWJlllDIUii)11JAll()tifltll(l'IOIJSIUWHll61JlJIIII.UDNhllW.. .ffill,.IITUM!IJIBEUSEl>ASQOmNJH • f"(MH Rl SD M:JSI II OOI("' IJlliSEO mmw Ol HKftNll CDIITOOOi. Th~ sign ,s mttndN! to be uutalW m ,KtOfd.ance with the rrquu;:i~tnU ol Article-600 ol tht Nation.I E.lectrul C~ and1or oth"r appkabl.> loul todM. Th•~ 1ndudes pro~ grounding and bond1"9 of the sign _1_ Dedicated ~ Amp Circuit at~ Volts E-Note #I: All requirements not in sign company's 1<ope of work must be in place prior to installation. E-Nate #2: Electrical to be brought to base of sign (by others) and not in sign company's scope of work. E-Note #3: Timers and/ar photocells for signs to be furnished and installed by lhe cuslome~s eledrician, who should also ensure !hut the completed eledricol system is code compliant. AU COMPONENTS TO BE® APPROVED All SIGNS TO BE ® LISTED LED HALO-ILLUMINATED CHANNEL LETTER SECTION PAINT SPACER PINS TO MATCH UNDERLYING ARCHITECTURAL FEATURE COLOR 2'-6" tall x 2 1/2 • deep halo-illuminated channel letters pin-mounted 1 1/2 • from 1/a • aluminum architectural feature Architectural Feature: 1/s • thick aluminum panel flush mounted to building exterior wall surface *NOTE: not part of signage 2 1/2 " tall x ¼•thick aluminum FCO copy pin-mounted flush to exterior wall surface 8 ¾•tall x 2 1/2" thick aluminum fabricated sign panel w/ routed copy bocked with 1/s • thick white (7328) acrylic CD SIGN A-HALO-ILLUMINATED CHANNEL LETTERS SCALE: 3/4" = 1' · o• QTY: [1] REF S.O. #30237 r,;\2 ?IDEVIEW \.!:.) SCALE: 3/4" = 1' -o• ffl~ 1160 Railroad St. ■ Sign age+ Fabrication Client Project: Revisions: Projecl No. 30237-R06 (PS) Corona, CA 92882 ■Displays+ Fixtures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad This is an original unpublished drawing crealed by A0/S Inc. It is T 800.862.3202 .L RI 10.21.19-dimensions odded lo show spoang belween lines ol copy Date. 2019-08-20 MS/JK/RT F951.278.O681 ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Caporale Offices 2668 Gateway Rd. Suite 170 sub mined foryourpersonal use in conjunction with a projecl being 5 Rl 10.23.19 -Sign B updated lo holo~illuminolion planned loryou by A0/S Inc. It is notlo be shown to anyone outside ■ ■ • www.ad-s.com 2835 Townsgote Rd. Suite 200 Carlsbad, CA 92009 your organization, nor is it lo be used, reproduced, copied or Sign Type. Sign A Westlake Village, CA 91361 c...L RI 10.24.19 -Sign A, olum panel revised to orchilecturol element exhibiled in any fashion without written permission fromAD/S Inc. file path. 6:\A0S 01awings\Wood Ranch B80 & Grill\WR Carslbad\30237\3 • permit\2 • exterior signage Sheet No: A.00 Jof12 "7 0,. ffl~ ■ ■ • 0 u.J 66'-0" DD □ ________,□ ~~ D [:J ,.___________, CD NORTH ELEVATION -CONTEXT ELEVATION, SIGN A SCALE: 1/8" = 1' -O" 1160 Railroad St. ■ Signage + Fabrication Corona, CA 92882 ■Dis p lays+ fixtures T 800.862.3202 F 951.278.0681 ■Ligh t ing+ Main t enance www.ad-s.com Clienl: WR Kitchen & Bar Carlsbad c/o Wood Ranch USA Inc. Caporale Offices 2835 Townsgate Rd. Suite 200 Westlake Village, CA 91361 file path: G:\A OS O rawings\Wood Ranch BB D & 6rill\WR Carslbad\30237\J -permit\1-exterior sign age Shea Properties. 11--------;C:J111--------1E::J Project Revisions: Projecl No: 30237-R06 (PS) WR Kitchen & Bar -Carlsbad ,\ RT: 10.21.19 -dimensions added lo show spacing between lines of copy This is an original unpublished drawing created by AD/S Inc. II rs 2019-08-20 . 4 Dale. MS/JK/RT submitted for your personal use in conjunction wilh a projecl being 2668 Gateway Rd. Suite 170 .:._l RT: 10.23.19-Sign B updo!ed lo holo-illuminolion planned for you by AD/S Inc. II is nol lo be shown lo anyone outside Sign A Carlsbad, CA 92009 your organilalion, nor is ii lo be used. reproduced. copied or Sign Type: ~-6~ RT: 10.24. 19 -Sign A, alum panel revised lo orchilecturol element exhibited in any fashion without written permission frorn AD/S Inc. Sheel No. A.10 4 of 11 COLOR SPECIFICATIONS: Pl : ■ Matthews Paint to match Pantone PMS 7623 C P2: ■ Matthews Paint to match Pantone PMS 7709 C P3: ■ Matthews Paint to match Sherwin Williams SW 7068 'Grizzle Gray' P4: LJ Matthews Paint SVOC 1304SP 'White' Shea Properties. Area of sign 0 face & returns 1 21.0 sq. ft. 0 face & returns 4'-4" I I I I I I I I I I I I I I STUCCO FASCIA----------- WALL STUD------------ 2 1/2" 11/2" .040" FABRICATED ALUMINUM RETURN -------, .060" FABRICATED ALUMINUM FACE -----rr==''== NON-CORROSIVE 1/4' DIA. RIVNUT & ----11---.:al:ll==~ THREADED ROD -NUT & WASHER FROM - BACKSIDE -2' NON-CORROSIVE SPACER MIN. FOUR (4) PER LITTER .187' THICK CLEAR LEXAN BACK ------11-----11 LIQUID TIGHT CONNNECTOR--------11---,rmJtiJ)i\l_illilll'i. POWER CABLE THRU 1/2° DIA. FLEXIBLE -----+I----_,,. METALLIC CONDUIT TO POWER SUPPLY AS REQ'D 12V POWER SUPPLY --- LOCATED IN RACEWAY BEHIND WALL LED STRIP-LIGHTING DOUBLE-STICK TAPED AND SCREWED TO LITTER BACK MIN. (2) 1/4" DIA. WEEP HOLES PER LITTER PAINT SPACER PINS TO MATCH UNDERLYING ARCHITECTURAL FEATURE COLOR 2'-6" toll x 2 1/2" deep halo-illuminated channel letters pin-mounted l 1/2 • from exterior wall surface Internally illuminated with Agilight SignRoyz 4500K LED modules PLYWOOD BACKING / -DISCONNECT SWITCH I l REQUIREMENT\ FOR ELECTRICAL ILLUMINATION J't'.lm EUOnc.tl. klSllill tOOfOWS JO IE fOltll:rJ ITOO!tS. A DHIICAJIO(lf(lJIT W'lN IIOWlf.lJllElflW.SOOAGIOtllilltffUtll lllilOlttl tU£llS H !IEOfOl.l'ifSl.llWI<N NOTE: ll'ilS N:tl&lliS ro IM[ SICili'S lNIEIMlil. Wlll!iGONl!, liOl lhE PIUU.ffW.lllfG. 1U ru.G<Ul:~MtSmM!:lSUH\llS Sltlll M flif ~GIOIJll:I fl,LIJ~"l'.TUltll'IU 1U ~ HA~ 1101r.mo SUl(H atom -rtmfWIRl:S UNt.~EUIU!.&GlO.;IIO ~W.lfSilE .11.li;.tllJMOfl16,lTliHNCOfflUU! .ll50 IIOflG,l.l;Q_ OF WIil IS DEIUM:,n IY Ill[ UliliTH Of a:!J~ ! .wtUGE AS PU NH u.rru Jll • GIDll!CIW'ltl Mll'iJ l'E CONtX'J(lJS UiD60fllM tHf SlGN TO lllf flJ$flllOUO 6200!1~ 9\.IS -VOllliGf. SH)UtfJ UAD ll)lOt[ TlWI l 'IJ!.JS mwm GIOI.~~ .urn !ltUruL -CONOOIICAIIIKlt8lUSlO.lSlilOCIIOM ,own Kl Sl6II Ml.'St IE ID["' OOIISEO [UilliCWI Ot EUOlKAl CONTOOOI. This ugo tS inteodtd 10 be Y'l~t.Ued in .ilccordaoce with tht-1eql11rements of Arte~ 600 of the N.iillOMI EIKtncal (odP .ilnd 'or Olher appfiablp loul codes ihis inc:ludtt propP1 grounding .ilnd bondmg of the ugn _1_ Dedicated ~ Amp Circuit ot ~ Volts E-Note # 1: A.II requirements not in sign company's scope of work must be in ploce prior ta installation. E-Note #2: Electrical to be brought to base of sign (by others) and not in sign company's scope of work. E-Note #3: Timers and/or photocells for signs to be fumished and instolled by the customer's electrician, who should also ensure that the completed electrical sy>lem is code compliant. ALL COMPONENTS TO BE® APPROVED ALL SIGNS TO BE ® LISTED LED HALO-ILLUMINATED CHANNEL LETTER SECTION 2' -6" toll x 2 1/2 • deep halo-illuminated channel letters pin-mounted l 1/ 2 • from exterior wall surface ---------------------/ 0 W O O D B A 1'T C H : 2 1/2" toll x 1/4" thick aluminum FCO copy I I I I I I I I I : BY 2 1/2 • toll x 1/4 • thick aluminum FCO copy pin-mounted flush to exterior wall surface ..,. --..,., I I I -----r------ ;:;:;-'-"' I co I •..,. . [: _____ 1__ __ ---------------------------------------------~ nl ■ ■ ■ 6'-3" CD ?IGN B -HALO-ILLUMINATED CHANNEL LITTERS SCALE: 3/4' = 1' -O' 1160 Railroad St. ■ Signage + Fabrication Corona, CA 92882 ■Dis plays+ Fixtures T 800.862.3202 F95l.278.0681 ■Lighting+ Ma intenance www.ad-s.com file path. G:\AOS O rawi ngs\Wood Ranch 880 & Grill\WR Carslbad\30237\3 · pmtil\1-exterior signage Client: WR Kitchen & Bar Carlsbad c/o Wood Ranch USA Inc. Coporote Offices 2835 Townsgote Rd. Suite 200 Westlake Village, CA 91361 pin-mounted flush to exterior wall surface 8 3/4 • tall x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy bocked with 1/ a• thick white (7328) acrylic Internally illuminated with Agilight SignRoyz 4500K LED modules located around interior perimeter of panel 0 all exposed surfaces 8 3/4 • toll x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy bocked with 1/s • thick white (7328) acrylic QTY: [1] REF S.O. #30237 r-;;\2 SIDEVIEW \!:.) SCALE: 3/4" = 1' -0" Project: Revisions Project No: 30237-R06 ( PS} WR Kitchen & Bar -Carlsbad This is an original unpublished drawing created by AO~ Inc. II is ...i.:,, RT, 10.21.19 -dimemion, added lo show spacing between lines ol copy submined loryour personal use in conjunclion wilfi a project being Date: 2019-08-20 2668 Gateway Rd. Suite 170 ...i~ RI 1013.19-Sign B updated to holo-illuminalion planned for you by AO~ Inc. II is not lo be shown to anyone outside Carlsbad, CA 92009 your oryanization, nor is it to be used, reproduced, copied or Sign Type: Sign B _6_ RT, 10.24.19-Sign A, alum panel revised lo orchilectural element exhibited in any fashion without written permission from AO~ Inc. Sheet No. B.00 MS/JI/RT 5 of 12 I I I I I I I I : 3'-4 ¾" : 1' I I l' 5'-8" t WR a T woo; •.a•o• KITCHEN & BAil 28' -4" 3'-4 ¾" 1 § ~-'---------'---------'--', ½ Shea! Properties. \ I ' I \/ __ ____.__.,GJ~-----'-', ffl~ ■ ■ ■ f"l\ SOUTH ELEVATION -CONTEXT ELEVATION, SIGN B V SCALE, 3/16' = r. o· 1160 Railroad St. ■ Sign age+ Fobrication Corona, CA 92882 ■ Oisploys + Fixtures T 800.862.3202 F 951.278.068 l ■Lighti ng+ Mointenonce www.ad-s.com file path: G.\ADS 0rawings\Wood Ranch BBll & Grill\WR Carslbad\J02JJ\J • pm1it\2 · uteri or signage Client Project: Revisions: WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad 4 RT, 10.21.19 -dimensions odded lo show spacing between lines of copy c/o Wood Ranch USA Inc. Coporate Offices 2668 Gateway Rd. Suite 170 ..f0 Rl 10.23.19-Sign B updated to halo-illumination 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 91361 _L RT, 10.24.19-Sign A, alum panel revised roorchilecturol elemenr Project No: 30237-R06 (PS) This is an original unpublished drawing created by AD/S Inc. It is 2019-08-20 submitted loryourpersonal use in conjunction with a project being Date. MS/JK/RT planned loryou by AD/S Inc. II is not to be shown to anyone outside Sign B your organization, nor is it to be used, reproduced, copied or Sign Type. exhibited in any fashion without written permission from AD/S Inc. Sheet No: 8.10 6 ol 12 COLOR SPECIFICATIONS: Pl: ■ Malthews Paint to motch Pantone PMS 7623 C P2: ■ Malthews Paint to match Pantone PMS 7709 C P3: ■ Malthews Paint to match Sherwin Williams SW 7068 "Griule Gray' P4: □ Malthews Paint SVOC 1304SP 'White• Area of sign 0 face & returns 1 4'-4" 21.0 sq. ft. 0 face & returns I I I I I I I I I I I I I I STUCCO FASCIA ---------- WALL STUD------------ 2 1/2' 11/2' .040' FABRICATED ALUMINUM RETURN ------~ .060" FABRICATED ALUMINUM FACE -----1<=1=d===;;i NON-CORROSIVE 1/4' DIA. RIVNUT & -----1\----..:::qj)!===t• THREADED ROD -NUT & WASHER FROM BACKSIDE -2' NON-CORROSIVE SPACER MIN. FOUR (4) PER LETTER .187" THICK CLEAR LEXAN BACK ------~---"11 LIQUID TIGHT CONNNECTOR-------~--,td~!.fil{t POWER CABLE THRU 1/2' DIA. FLEXIBLE ------jc\---- METALLIC CONDUIT TO POWER SUPPLY AS REQ'D 12V POWER SUPPLY -- LOCATED IN RACEWAY BEHIND WALL LED STRIP-LIGHTING DOUBLE-STICK TAPED AND SCREWED TO LETTER BACK MIN. (2) 1/4' DIA. WEEP HOLES PER LETTER PAINT SPACER PINS TO MATCH UNDERLYING ARCHITECTURAL FEATURE COLOR 2'-6" tall x 2 1/2 • deep halo-illuminated channel letters pin-mounted 11/2" from exterior wall surface Internally illuminated with Agilight SignRayz 4500K LED modules ---------------------/ 0 B Y W O O D B A N C H : 21/2"tallx ¼"thickaluminumFCOcopy : pin-mounted flush to exterior wall surface .,.., I PLYWOOD BACKING / -DISCONNECT SWITCH , REQUIREMENTS FOR ELECTRICAL ILLUMINATION rtawYHfOWlTOSl&lrilOWDSIOM"1t'!Ol:DIYOO!ltS A9f31UJIIIOi!C\ill 1ffll MOWltO Ml:UIWSA.110 .1.Gm:•11 minx 115 TO ~E ML IS tt01Jlt(0 fOt OISU.U.IJ:Oli NOTE: llf!SrU:WIISTOlrilSIGaSt~WI.Wlli'«iCNllr,NOIIHErlllWl'WftNG 1U llAISf(IIM{l:y'(li:Ml!S,fflMI SllfflJlS Wl.l If (Gf?6IOO'l f.WLl..fliTlltU"Eil ,US,QS!tAYf -DEO!W!IIWiCHOfflFI IBtf.EW'liS U'IIE,.li!t.1Ul,,&&ROI.INO 'MU\llt.Mi!ri:MUMOf l76l l}!l'l ct'ffl.W'tf. AISOIIOlf;&f.OCiE\)f W.tf. SOOttt.:"11:DIYniE Ult!il'H II t\Jli &W'UM.iEAS,ullECUJKU.JOO -GIOIJqw;lf MIJSI IEOlllTl.kOOiJS4N360fJOMI~ ~ IOl1if i'll!ELIIC»JOGIOl.li!GM WUJi6E SIOJLO READ MOUE 111.l~ l YOUS t[TWHN Gal.HID 4110 lillJIUL -CONlltlnCMlllllEUSl'D.I.SfitOOlrial'iN -POWEIIOSRMUSIIEDOll!ITAOOMHKIIIOO'OIHKlilCAI.IDNtOOOl TI11s s,gn rs intended to bt ms ta Red in accord.nee with thi' r~11~ment\ of ArtKk>600of the N.l1Jonal Electnc,1ICodeo1nd oroltm app!Kablt local codt-s TM includes proper grourn:hng i11nd bonding of tht sign _1 _ Dedicated ~ Amp Circuit al~ Volts E-Note #1: All requirements not in sign company's scope of work must be in place priar to instollatian. E-Note #2: Eledrical to be brought to bose of sign (by others) ond not in sign company's scope of work. E-Note #3: Timers and/or photocells lor signs la be furnished ond installed by the customers elecllician, who should also ensure that the completed electricol system is ,ode compliant. ALL COMPONENTS TO BE® APPROVED AU SIGNS TO BE ® LISTED LED HALO-ILLUMINATED CHANNEL LETTER SECTION 2'-6" tall x 2 ½" deep halo-illuminated channel letters pin-mounted l 1/2 • from exterior wall surface 2 1/2 " tall x ¼ • thick aluminum FCO copy pin-mounted flush to exterior wall surface 8 3/4 • tall x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy backed with 1/ a• thick white (7328) acrylic Shea Propenies. CD SIGN C -HALO-ILLUMINATED CHANNEL LETTERS SCALE: 3/4" = l' -o• QTY: [l] REF S.O. #30237 r,;\2 ?IDEVIEW \.!:..) SCALE: 3/4" = l' -O" ffl~ 1160 Roilrood St. ■ Sig n age + Fabrication Client: Project: Revisions. Project No: 30237-R06 (PS) Corona, CA 92882 ■Di splays+ Fi.tures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad ' This is an original unpublished drawing created by AO/S Inc. It is T 800.862.3202 ~ Rl I 0.21.19 -dimensions added 10 show spacing between lines ol copy submitted for your personal use in conjunction with a project being Date. 2019-08-20 F 951.278.0681 ■lighting+ Ma in te nance c/o Wood Ranch USA Inc. Coporate Offices 2668 Gateway Rd. Suite 170 ~ Rl 10.23.19-Sign 8 updoted lo holo-illuminotion planned loryou by AD/S Inc. It is not to be shown to anyone outside ■ ■ • www.od-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your organization, nor is it to be used, reproduced, copied or Sign Type. Sign C Westlake Village, CA 91 361 _L Rl 10.24.19 -Sign A, olum pone! revised lo orch1tecturol element exhibited in any fashion without written permission from AO/S Inc. file path. G:\A OS O rawings\Wood Ranch BBB & Crill\WR Carslbad\30237\3 · per111t\1 · eiterior signage Sheet No. C.00 MS/JK/RT 7 of 12 ffl~ • • • ½ ½ ½ ' ½ ½ ½ ½ ½ CD SOUTH ELEVATION -CONTEXT ELEVATION, SIGN C SCALE: 3/16" = 1' -o• 1160 Railroad St. ■ Signage + Fabrication Corona, CA 92882 ■Displays+ Fix t ures T 800.862 .3202 F951 .278.0681 ■L i ghting + Maintenance www.ad-s.cam file path: 6:\A0S 0rawings\Wood Ranch BB0 & Grill\WR Carslbad\30237\J · pm1it\2 · exterior signage 43'-9" 6'-3" 2'-4 3/4" WR KITCHEN & BAR ½ 1----7 I I ffi I I I I I I ½ I I I I I I ½ I I I I Client: Project WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad c/o Wood Ranch USA Inc. Coporate Offices 2668 Gateway Rd. Suite 170 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 91361 □ Shea Propenies. □ ' -' -.,.. Revisions. Project No: 30237-R06 ( PS) 4.:,. RT, 10.21.19-dimensiom odded lo show spacing between lines of copy This is an original unpublished drawing created by A0/S Inc. II is submitted for your personal use in conjunction wilh a project being Dale: 2019-08-20 MS/JK/RT _L RI 10.23.19 -Sign B updated 10 halo-illumination planned for you by A0/S Inc. II is nol to be shown lo anyone outside Sign C your organi1alion, nor is ii to be used, reproduced, copied or Sign Type. J__. RT, I 0.24.19-Sign A, olum panel revised to orchiledural element exhibited in any fashion without written pennission Imm A0/S Inc. Sheet No: C.10 80112 Area of banner 30.0 sq. ft . 7'-6" : BY WOOD RANCH @ o'-----------------------------------------------o -- ffl~ 1160 Railroad St. ■ Signage + Fabrication Client: Project: Corona, CA 92882 WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad T 800.862.3202 ■Display s+ Fixtures F951.278.0681 ■Light in g+ Mointenonce c/o Wood Ranch USA Inc. Coporote Offices 2668 Gateway Rd. Suite 170 ■ ■ • www.od-s.com 2835 Townsgote Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 91361 file path. G:\A0S 0rawings\Wood Ranch 880 & Grill\WR Carslbad\38237\J · permit\2 · exterior signage 0 Revisions: A Shea I Properties. 13oz. White banner; Digitally printed to match colors shown Bonner to be hemmed with grommets. 4 \ RT, I 0.21.19 -dimension, odded lo ,how ,pacing between lines of copy J.'... Rl 10.23.19-Sign B updated lo holo-illuminalion J_ Rl 10.24.19 -Sign A, alum panel revised lo architectural element This is an original unpublished drawing created by A0/S Inc. It 1s submitted for your personal use in conjunction with a project being planned for you by A0/S Inc. It is not to be shown to anyone outside your organi1ation, nm is it to be used, reproduced, copied or exhibited in any fashion without written permission from AD/S Inc. Project No: 30237-R06 (PS} Date: 2019-08-20 MS/J,JRT Sign Type: Sign D Sheet No: D.00 9 of 12 STATE OF CAUFORNIA SIGN LIGHTING CEC-NRCC-LTS-01· 08118 CALIFORNIA ENERGY COMMISSION II CERTIFICATE OF COMPLIANCE NRCC-L TS-01-E Shea Properties. Sign Lighting (Page 1 of S) .._...., Wood Ranch Kitchen & Bar• Carlsbad 10-23-19 A.. General Information ProjKt Address: 2668 Gateway Rd. Suite 170 Carlsbad, CA 92009 Location of Sign ~-Outdoor s;gns D Indoor Signs Phase of Sign Construction B NewSlgns D Sign Att:er.aitions !f' Not lnstallinR LiRhtinR Controls Type of Uirhtiru, Control 0 New Lighting Controls D Replaced Lil'htin" Controls This Ctrtific.ate of Compliance includes the following components (check 311 thiit appty): l?f' Specific Lighting Sources 0 Mandatory Measures (Lighting Controls) 0 Maximum Allowed Lighting Power 1. Mandatorv Si1n Lighting Controls NOTES: 1. The same responsible person may install both the sign lighting power and the sign lighting controls, or a different responsible person may install the sign lighting controls than the responsible person installing the sign lighting power. 2. The Mandatory Measures (sign lighting controls} are required for compliance with the sign lighting Standards. If the person responsible for installing the sign lighting power is not also responsible for the sign lighting controls1 then the owner of the sign, general contractor, or architect shall be responsible to have the sign lighting controls installed. 3. If more than one person has responsibility far compliance1 each responsible person shall prepare and sign a Certificate of Compliance and on Installation Certificate applicable to the portion of construction for which they ore responsible; alternatively, the person with chief responsibility for construction shall prepare and sign the Certificate of Compliance Declaration Statement for the entire construction (e.g. o C-10 contractor may complete parts 1a and lb on one compfiance document and a C--45 contractor may complete ports 2a and 2b an a separate compliance document -the Responsible Designer shall submit the two comolionce documents toaether for the same complete installation 1. I have responsibility for installing the sign lighting controls: 0 Yes, I have responsibility for the sign lighting controls, and will l?1" No, I do not have responsibility for installing the sign lightinc: controls. complete parts 13 3nd lb of this compliance document Someone else will complete parts la and lb of this compliance document. l a. Check Yes or No for all of the following statements: 1 There are existing sign lighting controls that comply with the applicable provisions of §110.9 and §130.3 □~ n ~ There are no existing sign lighting controls and I will be installing sign lighting controls that comply with the applicable 2 provisions of §110.9 and §130.3 0 Yes n No There are existing sign lighting controls that do not comply with the applicable provisions of §110.9 and §130.3 and I will be 3 installing sign lighting controls that comply with the applicable provisions of §110.9 and §130.3 □~ n ~ STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCC-lTS-01-Re'tlsed 08116 CAUFORNIAENERGYCOMMISSION 111 CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting (Page 2 of S) ,_._ Wood Ranch Kitchen & Bar• Carlsbad 10-23-19 lb. Mandatory Sien Lighting Controls If the person signing the Certificate of Compliance Declaration Statement on this NRCC-LTS-01-E is responsible for complying with the shim lighting control requirements, that person shall answer all of the followino questions: If there are construction documents, indicate where on the building plans the I mandatory measures (sion li11htino control) note block can be located: 1 §130.3(a)1. All indoor sign lighting is controlled with an automatic time-switch control or astronomical time-y N NA switch control. 0 0 0 §130.3(a)2A. AJI outdoor sign lighting is controlled with a photocontrol in addition to an automatic time-y N NA 2 switch control, or an astronomical time-switch control. 0 0 0 EXCEPTION to Section 130.3(a)2A: Outdoor signs in tunnels, and signs in large permanently covered outdoor y NA areas that are intended to be continuously lit, 24 hours per day and 365 days per year. 0 0 §130.3(a)2B. All outdoor sign lighting that is ON both day and night is controlled with a dimmer that provides the ability to automatically reduce sign lighting power by a minimum of 6S% during nighttime hours. Signs that y N NA 3 are illuminated at night and for more than 1 hour during daylight hours shall be considered ON both day and 0 0 0 ni•ht. EXCEPTION to Section 130.3(a}28: Outdoor signs in tunnels and large covered areas that are intended to be y NA illuminated both day and night. 0 0 §130.3(a)3. Demand Responsive Electronic Message Center Control. An Electronic Message Center (EMC) y N N/A having a new connected lighting power load greater than 15 kW has a control installed that is capable of 0 0 0 4 reducina. the lia.htimr: power bv a minimum of 30% when receivinR a demand response sianal. EXCEPTION to Section 130,3(a)3: Lighting for EMCs that is not permitted by a health or l~e safety statute, y NA ordinance, or regulation to be reduced by 30%. 0 0 Field Inspector Notes: CA Building Energy Efficiency Starwtards -2016 Nonresidential Compliance August 2016 STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCC-US-01-E/Revised 08/161 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-l TS-01-E Sign lighting (Page 3 of 5) Profec:t Name; Wood Ranch Kitchen & Bar -Carlsbad I O.te Prepal'M: 10-23-19 2. Mandatory Sign Lighting Measures I have responsibility for installing the sign lighting @ Yes, I have responsibility for the sign lighting, and will complete D No, I do not have responsibility for installing the sign lighting. Someone parts 2a and 2b of this compliance document else will complete parts 2a and 2b of this compliance document. 2a. Maximum Allowed lighting Power Method of Compliance Certificate of Compliance and Field Inspection Energy Checklist. Complete this part if there are signs using the maximum allowed lighting power method of compliance. (Complete part 2b of this Certificate of Compliance if there are signs using the Specific lighting Sources method of compliance). A B C DE F G H I J Symbol or Code A B C D G H Description of the Sign OPTIONAL- Energy Verified Label (see instructions below) ✓ □ □ □ □ □ □ □ □ □ □ □ □ □ □ i "' ~ < C: .!!!' V, Allotted Watts 0 w -0 0-N-tl =-C1J 0. "'.t: :!:.. "' ->~ ~~3 3.:.:->= .. = .. C: 3 N ~ 'O X ~ E ·e .. 0 ~ .. ::, ~~';: 3:-i iE = .2 < =-~ < 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Symbol or code used on the plans (when plans are required) and other documents. Design Watts Complies Y/N .., VI I -~ .!!1 a. E 0 u Field Inspector Check that Sign Complies ✓ □ □ □ □ □ □ □ □ □ □ □ □ □ □ A description of the sign, or location of sign on the building; and the location of sign on construction documents. OPTIONAL• Check this box only if this sign has a permanent, pre-printed, factory-installed, ENERGY VERIFIED label, confirming that the sign complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the Maximum Allowed Lighting Power method of compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories [UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, columns 'D' through 'I' are not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance. The sign area in square feet. List "I" if the sign is internally illuminated. List "E" if the sign is externally illuminated. Allowed watts per square foot. Enter 12 if t he sign is listed as "I" in column E. Enter 2.3 if sign is listed as "E" in column E. Multiply the square footage in column D times the allowed Lighting Power Density (LPD = watts) in column F. Show the total installed watts in the sign, as determined according to the applicable provisions of §130(c). Enter Y if the number in column H is less than or equal to the number in column G. Otherwise, the sign does not comply. This page doubles as a field inspection checklist. Field Inspector Notes: CA Building Energy Efficiency Standards· 2016 Nonresidential Compliance August 2016 ffl~ 1160 Roilrood St. ■ Signage + Fobrication Clienl: Prnjecl: Revisions: Project No: Corono, CA 92882 D isplays+ Fixtures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad This is an original unpublished drawing crealed by AD/S Inc. It is T 800.862.3202 ■ c..L RT: 10.21.19-dimensions added to show spacing between line, of copy submitted for your personal use in conjunction wilh a project being Date. F 951.278.0681 ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Coporate Offices 2668 Gateway Rd. Suite 170 , ,._L RT: 10.23.19 -Sign B updoled lo holo-illuminolion planned for you by AD/S Inc. II is not lo be shown to anyone outside ■ ■ • www.od-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your o<gani1ation. nor is it to be used. reproduced, copied or Sign Type. Westlake Village, CA 91361 ...!.., RT: 10.24.19-Sign A: alum panel revised lo architectural elemenl exhibited in any fashion withoul written pennission from AD/S Inc. file palh: G:\ADS D1awings\Wood Ranch 8 80 & Grill\WR Carslbad\30237\3 · pentit\2 · exterior signa ge Sheet No. 30237-R06 (PS) 2019-08-20 MS/JKJRT Title 24 T24.00 10 of 12 STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCC-US--01 E(Revised 08/16) - CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting (Page 4 of S} Project Name: Wood Ranch Kitchen & Bar -Carlsbad I ~te'1fl!:$Mlred: 10-23-19 CALIFORNIA ENERGY COMMISSION ■ STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCC-L TS--01-E{Revised 08/16\ CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting (Page 5 of 5) Project Name: Wood Ranch Kitchen & Bar -Carlsbad I Date Pre~red: 10-23-19 II 2b. Specific lighting Source Method of Compliance Certificate of Compliance and Field Inspection Energy Checklist Complete this part if there are signs using the Specific Lighting Source method of compliance. (Complete part 2 of this Certificate of Compliance if there are signs using the maximum allowed lighting power method of compliance} A B C D E DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signat~ Barbara Cohen Company: Signature Date: ~ Architectural Desion & Si11ns 08-20-19 Address: CEA Certification Identification (if applteable): OPTIONAL 1160 Railroad Street ENERGY Specific light source used for Field Inspector Symbol VERIFIED compliance or Description label Shall include only lighting Check that Sign Complies Code (see technologies listed below ✓ instructions (List all that apply) below} A Halo-Illuminated Channel Letters D 7 □ B Halo-Illuminated Channel Letters D 7 □ C Halo-Illuminated Channel Letters D 7 □ □ □ City/State/Zip: Phone: Corona, CA 92882 {951) 278-0680 X 124 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of (alifornia: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the california Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement □ □ □ □ □ □ □ □ A Symbol or code used on the plans (when plans are required) and other documents. B A narrative description of the sign, or location of sign on the building; and the location of sign on construction documents OPTIONAL -Check this box only if this sign has a permanent, pre-printed, factory-installed ENERGY VERIFIED label, confirming that this sign complies with the Section 140.8 of the california 2016 Title 24, Part 6 Standards, using the Specific Lighting Source Method of Compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories C (UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, column 'O' is not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the buililing owner at occupancy. Responsible Designer Name: Responsible Designer Signature: ~~ Milton Solomon Company: Date Signed: (IC Architectural Design & Signs 10-23-19 Address: License: 1160 Railroad Street 714309 City/State/Zip: Phone: Corona, CA 92882 (951) 278-0680 x122 compliance. Specific Light Source Compliance Method. The sign(s) identified above use only the following lighting technologies: List all applicable numbers (1 through 9) that apply in column D above for each row. 1 High pressure sodium lamps Shea I Properties. Metal halide lamps that are pulse start or ceramic served by a ballast that has a minimum efficiency of 88% or greater. 2 Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when tested according to ANSI C82.6-200S. Metal halide lamps that are pulse start that are 320 watts or smaller, are not 250 watt or 175 watt lamps, and are 3 served by a ballast that has a minimum efficiency of 80%. Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when tested according t o ANSI C82.6-2005. Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 75% when D 4 the transformer or power supply rated output current is less than 50 mA. The ratio of the output wattage to the input wattage is at 100% tubing load. Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 68% when 5 the transformer or power supply rated output current is 50 mA or greater. The ratio of the output wattage to the input wattage is at 100% tubing load. 6 Fluorescent lighting systems meeting one of the following requirements: A.) Use only lamps with a minimum color rendering index (CRI) of 80; or B.) Use only electronic ballasts with a fundamental output frequency not less than 20 kHz. 7 Light emitting diodes (LEDs) with a power supply having an efficiency of 80% or greater. Single voltage external power supplies that are designed to convert 120 volt AC input into lower voltage DC or AC output, and have a 8 nameplate output power less than or equal to 250 watts, shall comply with the applicable requirements of the Appliance Efficiency Regulations (Title 20). 9 Compact fluorescent lamps that do not contain a medium screw base sockets (E24/E26). E This page doubles as a field inspection checklist. Field Inspector Notes: CA Building Energy Efficiency Standards· 2016 Nonresidential Compliance August 2016 CA Building Energy Efficiency Standards -2016 Nonresidential Compliance August 2016 ffl~ 1160 Roilrood St. ■ Signage + Fabrication Client: Project: Revisions: Projecl No: 30237-R06 (PS) Corono, CA 92882 ■ Displays+ Fixtures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad ' This is an original unpublished drawing created by AO/S Inc. II is T 800.862.3202 _4~ RT, 10.21.19-d,mensions added la shaw spacing belween lines of copr 2019-08-20 submitted for your personal use in conjunction with a project being Date: MS/Jl/RT F 951 .278.0681 ■Light ing+ Maintenonce c/o Wood Ranch USA Inc. Coporote Offices 2668 Gateway Rd. Suite 170 5 RT: 10.23.19 -Sign B updoled lo holo-illuminalion planned for you by AO/S Inc. II is notlo be shown lo anyone outside • ■ • www.od-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your oryanizalion, nor is ii to be used, reproduced, copied or Sign Type . Title 24 Westlake Village, CA 91361 ~' RT: 10.24.19-Sign A, alum panel revised lo archilectural elemenl e1hibited in any fashion without written permission from AO/S Inc. file path. 6 :\AO SD rawings\Wood Ranch BB O & Grill\W R Carslbad\30137\3 • pmril\2 · exterior signage Sheet No: 124.10 110111 STATE OF CALIFORNIA SIGN LIGHTING STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCI-LTS-01-E {Revised (01/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTS-O1-E Sign Lighting Page 1 of 2 Project Name: Wood Ranch Kitchen & Bar -Carlsbad Enforcement Agency: Pennit Number: ProjectAddress: 2668 Gateway Rd. Suite 170 City: Carlsbad Zip Code: 92009 CEC-NRCI-LTS-01-E {Revised 101/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTS-O1-E Sign Lighting Page 2 of 2 Project Name: Wood Ranch Kitchen & Bar -Carlsbad Enforcement Agency: Pennit Number: Project Address: 2668 Gateway Rd. Suite 170 City: Carlsbad Zip Code: 92009 Ill GENERAL INFORMATION DATE OF PE RMIT: PERMIT NUMBER: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: LOCATION OF SIGN(S): □ Outdoor Sign(s) □ Indoor Sign(s) Documentation Author Company Name: Date Signed: PHASE O F CONSTRUCTION: □ New Sign(s) □ Sign Alteration Address: CEA Certification Identification (If applicable): SCOPE OF RESPONSIBILITY City/State/Zip: Phone: Enter the date of approval by enforcement agency of the Certificate of Compliance that provides the specifications for the energy efficiency measures for the scope of responsibility for this Installation Date: RESPONSIBLE PERSON'S DECLARATION STATEMENT Certificate. I certify the following under penalty of perjury, under the laws of the State of California: In the table below identify all applicable construction documents that specify the requirements for the scope of responsibility reported by this Installation Certificate (continued). Document Title or Description Applicable Sheets or Pages, Tables, Date Approved by Schedules, etc. Enforcement Agency 1. The information provided on this Certificate of Installation is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements 4. given on the plans and specifications approved by the enforcement agency. I reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements SheaJ Properties. that apply to the construction or installation have been met. 5. I will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Company Name: {Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (TiUe): Address: CSLB License: City/State/Zip: Phone I Date Signed: CA Building Energy Efficiency Standards -2016 Nonresidential Compliance January 2016 CA Building Energy Efficiency Standards -2016 Nonresidential Compliance January 2016 ffl~ 1160 Railrood St. ■ Signage + Fabrication Client: Project: Revisions: Project No: 30237-R06 (PS) Corona, CA 92882 ■Displays+ Fixtures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad T 800.862.3202 _J_, RI 10.21.19-dimensions added to show spacing belween lines ol copy This is an original unpublished drawing created hy AD/S Inc. It is 2019-08-20 c/o Wood Ranch USA Inc. Caporale Offices suh111ined for your pmonal use in conjunction with a project being Date: MS/JK/RT F 951.278.0681 ■Lighting+ Maintenance 2668 Gateway Rd. Suite 170 s'~ RT: 10.23.19 -Sign 8 updated lo halo-illumination planned for you hy AD/S Inc. It is not ID he shown lo anyone outside ■ • ■ www.od-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your organization. nor is it to he used. reproduced, copied or Sign TYJ!e: Title 24 Westlake Village, CA 9136 l ~ RT, 10.24.19-Sign A, olum panel revised lo orchile<lurol element uhihited in any fashion without written permission fromAD/S Inc. Iii e path. 6. \ADS O rawings\Wood Ranch B BO & 6rill\WR Ca rslhad\30237\3 · per111it\2 · exterior signage Sheet No. 124.20 12 of 11 file palh: G:\AOS Orawings\Wood Ranch 8 80 & Grill\WR Ca rslbad\3023713 • permil\2 • exleri or signage D Conceptual Package 0 Permit Package D Production Package REALITY BEGINS WITH VISION Prepared for: BY WOOD RANCH Project Address: 2668 Gateway Rd. Suite 170 Carlsbad, CA 92009 'OOJdOl't-C2.\'1 SIGN PERMIT NO. PS ~ottt-o\t:1'\: APPROVED BY PLANNING at : lh-., ~-T - BUILDING Scope of Work: From: BARBARA COHEN cell: 714.906.2029 email: bcohen@od-s.com COLOR DISCLAIMER From : MILTON SOLOMON cell: 949.678.2878 email: msolomon@od-s.com SIGN TYPE SIGN NUMBER ILLUM DIMENSIONS Halo-Illuminated Channel Letters -y 4'-6" X 6' -3" Halo-Illuminated Channel Letters -N 4' -4" X 6' -3" Halo-Illuminated Channel Letters -y 4' -4" X 6' -3" Temporary Banner CD N 7'-6" X 4'-0" Clienl Name !Please Prinl) _________ _ Dale_/_/_ Dae ta tie limitaliois ol des~o, scmm and the 1elative ,ncm,stencies thanm d~play■Hilm a,d ,n,teis. the colors rn see oa you, mm aru papei~a, 111 le a ttlal~ accmle 111rod1ct10, 11th, actial ,rod.ct We st1oe t1 ■ale 11r c11trs as accmt, as ,essillt, bat sc11t1 ad ,nnted images m 11teedeias a guide enl1 and should ,01 le rega1ded as absol1tel1mrect. Site md1t1m and mite lighting can also afftct how the 11oducta,,ea1S r, ,. LEO, difft111illtrescent lalhs, ~ateral ~!bl BacUit Hal1lit facelrt). We 1eco11mend tbt you request• color sample as CIIYl (Cyan. lla1uta, Yellowa,d Black) are the celo,s md i, tht Jrilting proctss. wht1tas RGB (Rei 61m and B1111 are the tl~IS md b1 sc1m displays mh as )'11" m11rto1. fDltltis 1eam a Ad due to 1ariat1m i,t1educed Irr light ao1,arim eqUJpmut tit colt,s "y,11 scrm a, a Jrilt mar HI mctlr 1atcb tbt fi•~itd p11d,ct Clien!Name !Signature) ________________ _ If you would like to see a sample of any color, please req■est a■ aclllaf sample kom yoar Salesperso■ or Project Maaager. WITHOUT A SIGNED COLOR SAMPU, AD/S COMPANIES, ITS VINDORS ANO AFFILIATES ARE NOT RESPDNSIBU FOR DIFFERENCES, REAL OR PERCEIVED. BETWEEN THE WAY YOUR PRODUCT APPEARS ON SCREEN OR PAPER ANO rHE FINAL PRODUCT. PLIASE INITIAL All PAGES AD/S Drawing #30237 Rev. #06 (PS) Rev. Date, lD-24-19 Pages, 12 (Including Cover Sheet) DATE t o/~f"- I QTY sa FT 1 22.5 1 21.0 1 21.0 30.0 □ Approved □ Approved as Noted □ Revise & Resubmit □ Rejected , • KITCHEN & BAil - BY WOOD B.ANCB KITCHEN & BAil BY WOOD B.ANCB KITCHEN & BAil - GATEWAY ROAD NORTH CD SITE PLAN SCALE: 1/32' = l' · O" '111 1160 Railroad St. ■ Signoge + Fabrication Client: Project: Revisions: Project No: 30237-R06 (PS) Corona, CA 92882 ■Displays+ Fix t ures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad ~ Rl 10.21.19 -dimensions odded to show spacing between lines of copy This is an original unpublished drawing created by AD/S Inc. II is T 800.862.3202 submitted for your personal use in conjunction with a project being Date: 2019-08-20 MS/JK./RT F 951.278.0681 ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Coporote Offices 2668 Gateway Rd. Suite 170 L.L. Rl 10.23.19-Sign B updoted lo holo·illuminotion planned for you by AD/S Inc. It is not lo be shown to anyone outside • • • www.ad-s.com 2835 Townsgote Rd. Suite 200 Carlsbad, CA 92009 your oryanization, nor is it lo be used, reproduced, copied or Sign lype: Site Plan Westlake Village, CA 91361 ~ RT: l 0.24.19 -Sign A: olum panel revised lo orchiterturol elemenl exhibited in any fashionwilhoul written permission from AD/S Inc. file path: G. \ADS Drawings\Wood Ranch B Bll & 6rill\WR Carslbad\J D2J7\J · p mril\1-exterior signage Sheet No: SPl .00 2 of 12 • COLOR SPECIFICATIONS: Pl: ■ Matthews Paint to match Pantone PMS 7623 C P2: ■ Matthews Paint to match Pantone PMS 7709 C P3: ■ Matthews Paint to match Sherwin Williams SW 7068 'Grizzle Gray' P4: ~ Matthews Paint SVOC l304SP 'White' Area of sign 22.5 sq. ft. ffl~ • • • 0 face & returns 4'-4" 1 --------------------- 6'-3" CD SIGN A -HALO-ILLUMINATED CHANNEL LETTERS SCALE: 3/4' = l' -o• 1160 Railroad St. ■ Signoge + Fabrica tion Corona, CA 92882 T 800.862.3202 ■Displays+ Fixtures F951.278.0681 ■Lighting + Maintenance www.ad-s.com file path: 6:\AO S O rawings\Wood Ranch B Bll & Grill\WR Carslbad\30137\3 · per1nit\1 · uteri or signage 0 face & returns Client WR Kitchen & Bar Carlsbad c/o Wood Ranch USA Inc. (operate Offices 2835 Townsgote Rd. Suite 200 Westlake Village, CA 9136 l 1/8' ALUMINUM --------~ WALLSTUD ------------ 2 1/2" 11/2" .040" FABRICATED ALUMINUM RETURN ------~ .060' FABRICATED ALUMINUM FACE ---- NON-CORROSIVE 1/4' DIA. RIVNUT & -----lt-----.::iq~==:;'.F THREADED ROD -NUT & WASHER FROM BACKSIDE -2' NON-CORROSIVE SPACER MIN. FOUR (4) PER LETTER .187' THICK CLEAR LEXAN BACK ------l!-----■J LIQUID TIGHT CONNNECTOR-------~--1itt!lllllll~ POWER CABLE THRU 1/2' DIA. FLEXIBLE---~:1--_,.- METALLIC CONDUIT TO POWER SUPPLY AS REQ'D 12V POWER SUPPLY --- LOCATED IN RACEWAY BEHIND WALL LED STRIP-LIGHTING DOUBLE-STICK TAPED AND SCREWED TO LETTER BACK MIN. (2) 1/4' DIA. WEEP HOLES PER LETTER 2' -6' tall x 2 1/2 • deep halo-illuminated channel letters pin-mounted l 1/2 • from 1/a • aluminum architectural feature Internally illuminated with Agilight SignRayz 4500K LED modules 8 3/4 • tall x 2 1/2' thick aluminum fabricated sign panel w/ routed copy backed with 1/a • thick white (7328) acrylic Internally illuminated with Agilight SignRayz 4500K LED modules located around interior perimeter of panel 0 all exposed surfaces REQUIREMENTS FOR ELECTRICAL ILLUMINATION f't.lUJfEUCUIOtfOSSI.OC.lllONSlOIEN(JVl.1101'!'00!1ts. l DUl!C11EOO'(Un Wlr!I JIOSH1lH!tl:llTRAI.Sl'OAGIOt11Drffib N610tff[Ml1Stf0t; IEOFOII !llstAU.AJ!O!I PLYWOOD BACKING NOTE: lhlS l'UIAINS 10 ltlf ~ Hrdtt'UI. Wltllil60lllY, .of TIIE ffiiW'I' Wlt.116. AUtUNSfOtME~tSIJffl.JfSSHAUIIE~l)GilOl.lf)fAIIU--OOlrtUffiO JUSPSlii't'I ~~DIOJ(0WllOI0IOJII f111H WltlS Ull, liltUIUl. l61NJiD -WllfSllE fiJl;MLMOf 11GA. 0'-lltt«ffl•W'.tE llSOl10ll(.AL161 (I llllrEtSlllElllJIDff Pit l.EllfilltC,M tilNftMiE iSPEI ~1{UOOf 300 -&IDLINDW'l:l:.rsfSf(Ollll!U)liSA.it.,60fil)lflfl'SliNIOJIIEf'.l.li!OOIJDGIQ';IIDltlS.. -'IOLUGESKOOtDIEA,,11>.wlRtTHUilWl.~8£1WHN6lOU!llliNOli[tillil -CCll:llllCAII !1,)1 t£USEnAS90!NDM PIMf.t JOSS! MUSI Sl !lOIIE Sf A OOltS(DHKJb'.WI OIHI-OIICALCOOOOOl. DISCONNECT SWITCH TlHS sign~ IT\(NidPd to be IMtalled ,n occOl'd.111'JCt with lh~ feQ\Jlft'M~nu of Art1clP600 of the National Ek-c1nul Code and 10, OlhH apphcabl(> local codes Th,~ w,clude! pro~r ground mg end bonding of the \tSn I _1 _ Dedicated ~ Amp Circuit at~ Volts E-Note #I: All requirements~ in sign company's scope of work must be in ploce prior lo inslallotion. E-Nole #2: Eleclrical to be broughl lo base of sign (by others) ond nol in sign company's scope of work. E-Note #3: nmers and/or photocells for signs to be furnished and installed by the custome(s electrician, who should also ensure that the completed elec1rical system is code compliant. ALL COMPONENTS TO BE® APPROVED ALL SIGNS TO BE ® LISTED LED HALO-ILLUMINATED CHANNEL LETTER SECTION 2' -6' tall x 2 1/2 • deep halo-illuminated channel letters pin-mounted l 1/2 • from 1/a • aluminum architectural feature Architectural Feature: 1/a • thick aluminum panel flush mounted to building exterior wall surface *NOTE: not part of signage 2 1/2 • toll x ¼ • thick aluminum FCO copy pin-mounted flush to exterior wall surface 8 3/4 • tall x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy backed with 1/a' thick white (7328) acrylic QTY: [l] REF S.O. #30237 r,;\2 SIDEVIEW \...V SCALE:3/4' = l' -o• Project: Revisions: Project No: 30237-R06 {PS) WR Kitchen & Bar -Carlsbad .'\ This is an original unpublished drawing created by AO/S Inc. It is ,.._!:,. Rl 10.21.19 -dimensions added lo show spacing belween lines of copy Date. 2019-08-20 submitted for your personal use in conjunction with a project being 2668 Gateway Rd. Suite 170 ~5~ Rl 10.23.19 -Sign B updated lo holo-illuminotion planned for you by AO/S Inc. It is not 10 be shown to anyone outside Carlsbad, CA 92009 your organiiation. nor is it to be used. reproduced, copied or Sign Type: Sign A LL, RT: 1014.19 -Sign A, olum panel revised to orchitedural elemenl eihibited in any fashion withoul written permission from AO/S Inc. Sheel No: A_OO MS/JI/RT J of 11 n • • • C!I ..... C!I ..... 66' -0" I ,,.--,--.... I 8'-2" 6',j3" 1" ~·/ f ,/ I . . -------------------------------- -------------------------- DD □ □ .L------.------Tl D [:] .,__________,__ □ 1160 Railroad St. ■ Signage + Fabrication Client: Corona, CA 92882 WR Kitchen & Bar Carlsbad T 800.862.3202 ■Displays+ Fixtures F 951.278.0681 ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Caporale Offices www.ad-s.com 2835 Townsgate Rd. Suite 200 Westlake Village, CA 91361 file path. G:\ADS Drawings\Wood Ranch 880 & Grill\WR Carslbad\30237\3 · permit\2 · exterior signage ll-------ilte:J,......_ __ ____.,C=:J . I fl Project: Revisions: Project No: 30237-R06 {PS) WR Kitchen & Bar -Carlsbad \ This is an original unpublished drawing created by AD/S Inc. It is ~ RI 10.21.19-dimensions odded lo show spodng belWeen lines of copy submitted for your personal use in conjunction with a project being Date: 2019-08-20 MS/Jl/RT 2668 Gateway Rd. Suite 170 _5~ RT: 10.23.19-Sign B updated to halo-illuminotion planned for you by AD/S Inc. It is not to be shown to anyone outside Sign A Carlsbad, CA 92009 !..£,, RT: 10.24.19 -Sign A: alum ponel revised to orchitecturol element your oryanization, nor is it to be used, reproduced, copied or Sign Type: exhibited in any fashion without written per11ission fro11 AD/S Inc. Sheet No: A.10 4ol12 COLOR SPECIFICATIONS: Pl: ■ Matthews Paint to match Pantone PMS 7623 C P2: ■ Matthews Paint to match Pantone PMS 7709 C P3: ■ Matthews Paint lo match Sherwin Williams SW 7068 'Grizzle Gray" P4: □ Matthews Paint SVOC 1304SP 'White• Area of sign 0 face & returns 21.0 sq. ft. 0 face & returns 2 1/2" I 1/2" STUCCO FASCIA ------------ WAU STUD ------------ .040" FABRICATED ALUMINUM RETURN ------~ .060" FABRICATED ALUMINUM FACE ---- NON-CORROSIVE 1/4' DIA. RIVNUT & ----+---cqt===t THREADED ROD -NUT & WASHER FROM BACKSIDE -2' NON-CORROSIVE SPACER MIN. FOUR (4) PER LETTER .1ar THICK CLEAR LEXAN BACK ______ --l[..---1 1 LIQUID TIGHT CONNNECTOR-------+---,,l~~il1.,il1.,(L.il{ POWER CABLE THRU 1/2' DIA. FLEXIBLE METALLIC CONDUIT TO POWER SUPPLY ASREQ'D 12V POWER SUPPLY ---- LOCATED IN RACEWAY BEHIND WALL LED STRIP-LIGHTING DOUBLE-STICK TAPED AND SCREWED TO LETTER BACK MIN. (2) 1/4' DIA. WEEP HOLES PER LETTER PLYWOOD BACKING r DISCONNECT SWITCH REQUIREMENTS FOR ELECTRICAL ILLUMINA !ION !'t'JUlf!UOIIC.lllOSSIIDCAIIONSIOII PIJ'f:IOITOfil[ts. AOE!lWEOmam WllliNOSWEDIIEJTWSiN'li~WDtfM!illlliTOill!f'i.llllSl!OiJ'UOfc.lltSU,ll.llllft NOH: Jt<IS l'lll,1.IISI001fSIGll'itlll£tNAI.W.t!ll60ND',liOf lllt N:JUJ'\'W:il~ JU IU.'ISfOOilr:/.W"YEl5r'l'OWEtSUl'fll!SSIIIILlllfGFQQ)UND f.lUU.Jlfnttt.,m Jl.l.SIGICSRI.Yl -tfDICl!EOW..'CIORrull -lrltUWltlS 1.ililllEUTUl,&GJDI.IID WltfSlliML~CWl2""1H"lll(OffltWm tiSOliOU CllJQ(fW.tftSllflUM.NIOl'fUt(lf!IGn!CftlJll&AM:IAGl.SN:tHE(IJOO!l)O 6IOUMIW11:EM,JSll~IJOU'S.fJD60flDlilOIISQTOMPij!OOUQ6IOU-:IIJS -WU"61:SHCllllllEA3llODtlhU3WUSlfTWHMGlOl.lOIJi)MI.UTUL ·CON!lHTWIMJTIEWIJI.SlilOOl!IJPWI POO.tIOS8.llll'iJlf:DOM IYll.klNSEDHKTml'ot!UOtKAl(OtllOOOt_ This stgn rs ,nt!'flded tobe ,mr.tled m acconf.anci.-w1th the rt'q'Jn·t,.,@'flh of Ar11Cle 600ol 1he Nar10nal E~trw:al(odt i1ndlo1 ottm ilppliublll!- loul codes Th1\ indudts proper grounding ilnd bondmg of th~ 119n _1 _ Dedicated 1!_ Amp Circuit at~ Volts E-Note #1: All requirements not in sign company's scope of work must be in place prior lo installation. E-Note #2: Eledrical to be brought to base of sign (by other>} and not in sign company's scope of work_ E-Note #3: nmers ond/or photocells for signs lo be furnished ond installed by the customer's ele<tri<ion, who should also ensure tho! the completed ele<trical system is code compliant. ALL COMPONENTS TO BE® APPROVED ALL SIGNS TO BE ® LISTED LED HALO-ILLUMINATED CHANNEL LETTER SECTION 1 4'-4" 2112 · M 1112· Ll"'I ffl~ 1160 Railroad St. Corono, CA 92882 T 800.862.3202 F 951.278.0681 ■ ■ ■ www.ad-s.com ---, I I I ---'-'------- I I I I I I I I I I I I I I I I I I I I I I I I I I I I 2'-6" tall x 21/2" deep halo-illuminated channel letters pin-mounted l 1/2" from exterior wall surface Internally illuminated with Agilight SignRayz 4500K LED modules ! ----------------------/ 0 : B Y WO O D R AN C H : 2 1/2"tallx l/4"thickaluminumFCOcopy : pin-mounted flush to exterior wall surface I 6'-3" ■ Sign age + Fabrication Clienl: 8 ¾ • tall x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy backed with 1/a" thick white (7328) acrylic Internally illuminated with Agilight SignRayz 4500K LED modules located around interior perimeter of panel 0 all exposed surfaces QTY: (1] REF S.O. #30237 Projecl: Revisions: " r,;\2 SIDEVIEW \!:.) SCALE: 3/4" = 1' -0' 2'-6" tall x 2 1/2" deep halo-illuminated channel letters pin-mounted l 1/2 • from exterior wall surface 2 1/2" tall x 1/4 • thick aluminum FCO copy pin-mounted flush to exterior wall surface 8 3/4 • tall x 2 1/2" thick aluminum fabricated sign panel w/ routed copy backed with 1/a" thick white (7328) acrylic Project No: 30237-R06 (PS) ■Display s+ Fixtures WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad This is an original unpublished drawing created by AD/S Inc. II is ,_L RT, 10.21.19 -dimen1ion1 added lo show spacing between lines ol copy Date. 2019-08-20 submitted for your personal use in conjunclion with a project being ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Coporate Offices 2668 Gateway Rd. Suite 170 c..L RT: 1013.19-Sign B updated lo holo-illuminotioo planned for you by AO/S Inc. II is not Jo be shown to anyone outside 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your organization, nor is ii lo be used, reproduced, copied or Sign Type: Sign B Westlake Village, CA 91361 _L, RT, I 0.24.19 -Sign A, alum panel revised lo orchitedurol elemenl exhibited in any lashion wilhoul wrilten permission fromAO/S Inc. lile path: 6:\AOS Orawings\Wood Ranch 880 & Grill\WR Carslbad\30237\3 · permit\2 • exterior signage Sheet No: B.00 MS/JJJRT 5 ol 12 28' -4• ffl~ ■ ■ • I I I I I I I I : 3'-4 ¼" : 1· I I 1· 5'-8" 3'-4 ¼" 1 f WR KITCHEN & BAB ½ ½ I I I ½ ½ \ / I \ I I I CD SOUTH ELEVATION -CONTEXT ELEVATION, SIGN B SCALE: 3/16' = l' -o• 1160 Railroad St. ■ Sign age + Fabrication Corona, CA 92882 T 800.862.3202 ■Displa y s + Fixtures F 951 .278.0681 ■Lighting+ Ma intenance www.od-s.com file path: G:\AOS Orawi ngs\Wood Ranch BB O & Grill\WR Carslbad\30137\3 -pm,it\1 · exterior signage _----'--'iGJ______....., Clienl: Project: WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad c/o Wood Ranch USA Inc. (operate Offices 2668 Gateway Rd. Suite 170 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 9136 l Revisions: Project No: 30237-R06 (PS) \ This is an original unpublished drawing created by AO/S Inc. It is Li... RT, 10.21.19-dimensions added to show 1po,ing between lines of ,apy Date: 2019-08-20 MS/mRT ., submitted for your personal use in conjunction with a project being c..i.. Rfc 1013.19-Sign B updated to halo-illumination planned for you by AO/S Inc. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or Sign Type. Sign B _L RT, 1014.19-Sign A, alum ponel revised to or<hitecturol element exhibited in any fashion without written permission from AO/S Inc. Sheet No. B.10 6 of 11 COLOR SPECIFICATIONS: Pl: ■ Matthews Paint to match Pantone PMS 7623 C P2: ■ Matthews Paint to match Pantone PMS 7709 C P3: ■ Matthews Point to match Sherwin Williams SW 7068 'Grizzle Gray• P4: □ Matthews Paint SVOC l304SP "White• Area of sign 0 face & returns 1 4'-4' 21.0 sq. ft. 0 face & returns --------------------------------1 I I I I I I I I I I I I I I I I STUCCO FASCIA------------ WALL STUD ------------ 2 1/2" 11/2" .040' FABRICATED ALUMINUM RETURN ------~ .060' FABRICATED ALUMINUM FACE ______ rr======n1 NON-CORROSIVE 1/4' DIA. RIVNUT & ----+---.qt==~ THREADED ROD -NUT & WASHER FROM BACKSIDE -2' NON-CORROSIVE SPACER MIN. FOUR (4) PER LITTER .187" THICK CLEAR LEXAN BACK -------Jt----■I LIQUID TIGHT CONNNECTOR--------1!------tlJJl~.Jl.Jl.ill-;. POWER CABLE THRU 1/2' DIA. FLEXIBLE-------- METALLIC CONDUIT TO POWER SUPPLY AS REQ'D 12V POWER SUPPLY ---- LOCATED IN RACEWAY BEHIND WALL LED STRIP-LIGHTING DOUBLE-STICK TAPED AND SCREWED TO LITTER BACK MIN. (2) 1/4" DIA. WEEP HOLES PER LITTER 2'-6' toll x 21/2' deep halo-illuminated channel letters pin-mounted l 1/2" from exterior wall surface Internally illuminated with Agilight SignRoyz 4500K LED modules I I I I I I I I I I I I I I I I I I I I I I : BY ---------------------/ 0 WO O D B. A l'l C B : 21/i"tollx ¼'thickoluminumFCOcopy I I I -----r -----~ ;;;-U"\ I co I · .... [: _____ I -----------------------------------------------" 6'-3" pin-mounted flush to exterior wall surface 8 ¼ • toll x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy bocked with 1/a • thick white (7328) acrylic Internally illuminated with Agilight SignRoyz 4500K LED modules located around interior perimeter of panel 0 all exposed surfaces QTY: [l] REQUIREMENTS FOR ELECTRICAL ILLUMl~ATION PIIJiUJ't'!lKftlll.lOS81lOCAJIOIISIOlf PIJ'i':JEIIIYOf1iUS AD«KAftDCIIOHl W'lHliOWl!DII.IIIWSllllAGI001'3tf1Uth1'1iJOTifEl'UiEllSftOUIIIDfOllltSW.LAl'O'C NOTT. UtlSPflllltSIOntESl&fS NTIWI.W'U&CNilY,J(IIMPtwll'W".lllli IUIW5fOtMl.fi'MMl'vPIMtlgiPftJlsSIW.l.•l'6fQGIOUlllf&i.;U~IITTIUfEO PLYWOOD BACKING Ml SPSHAVl -tlUMWED WllQIORCl./11 Tl!tHW11fS,Ult£,NH!WL.lW~ W!l£W£,.1.NlMU.IOf 1264.IHIINCOPnlW'll JiSOIIOH GALlliOfW.11:ISIUEbiMEOlflMUNGIBOfl'Jll&WfltMiEASN:tMKWIClJXXI. -GlOWitlW!tEIIAI.ISlat:COll1b:tJOUS~60fllMIH£51GNKIIHE11mM»JDGROJ!tCt:JS VOl.1.IGE St!Ol,'UIJl@~ ,Gt lrJ.11 l VOi.i'S l{IWUN EiDI.ICJ Alf) ~EUR.Al ctli:1!11{.Ul!(II.USEDAS!il(l,lflM . ,o#lt Kl S1611 llUSI IE IIO!i£ r, A OOJISEO UfObCW! OlU.EOltlC&l CDIIJOOOi DISCONNECT SWITCH Thts ugn 15 mtimded to ht lMt<I~ lfl ,il((O!diiOCf WJ!h tlw ffqUlf{'"1tOt\ of Artide600 of the Na110rwl El!'<trul(OM •nd1orotht-r applic.iblt loc.alcodf'\ Tlu\ indudes propff grounding and bonding of the 119n I _I _ Dedicated _!!_ Amp Circuit at~ Volts E-Note #1: All requirements not in sign company's stope of work must be in place prior to installation. E-Note #2: Eledricol to be brought to bose of sign (by others) and not in sign compony's scope of work. E-Note #3: Timers ond/or photocells for signs to be furnished ond installed by the customer's ele<lrician, who should olso ensure that the completed electricol system is code compliont. ALL COMPONENTS TO BE® APPROVED All SIGNS TO BE @ LISTED LED HALO-ILLUMINATED CHANNEL LETTER SECTION 2'-6' toll x 21/2" deep halo-illuminated channel letters pin-mounted l ½•from exterior wall surface 2 ½ • toll x ¼ • thick aluminum FCO copy pin-mounted flush to exterior wall surface 8 ¼•tall x 2 1/2 • thick aluminum fabricated sign panel w/ routed copy bocked with 1/a" thick white (7328) acrylic REF S.O. #30237 ("";;"\2 ~IDEVIEW \.!:.) SCALE: 3/4' = l' -o• ffl~ 1160 Railroad St. ■ Signage + Fabrication Client: Project: Revisions: Project No: 30237-R06 (PS) Corona, CA 92882 WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad "' This is an original unpublished drawing created by AD/S Inc. It is T 800.862 .3202 ■D isplays+ Fixtures 4 RI 10.21.19-dimensions added to show spacing between lines ol copy 2019-08-20 submitted for your personal use in conjunction wilh a project being Dale: F 951.278.0681 ■Lighting+ Ma intenan ce c/o Wood Ranch USA Inc. Coporote Offices 2668 Gateway Rd. Suite 170 _t, RI 10.23.19-Sign B updated lo holo-illuminotion planned for you by AD/S Inc. It is not 10 be shown to anyone outside ■ ■ ■ www.ad-s.com 2835 Townsgote Rd. Suite 200 Carlsbad, CA 92009 j _, your oryani1ation, nor is it to be used, reproduced. copied or Sign lype: Sign C Westlake Village, CA 91361 RT: 10.24.19 -Sign A: olum panel revised lo orchitecturol element exhibited in any fashion wilhout written permission from AO/S Inc. file path: G.\AO S D rawin gs\Wood Ranch BB n & Grill\WR Carslbad\30237\3 • permit\2 • uteri or signage Sheet No: C.00 MS/JKIRT 70112 ffl~ ■ ■ ■ ½ ½ ½ ½ \ ½\ ½ I ½ CD SOUTH ELEVATION -CONTEXT ELEVATION, SIGN C SCALE: 3/1 6' = l' -O" 1160 Railroad St. ■ Signage + Fabrication Corono, CA 92882 ■Displays+ Fixtures T 800.862.3202 F95l.278.0681 ■Lighting+ Maintenance www.ad-s.com file palh : G:\AOS D rawings\Wood Ranch 880 & Grill\WR Canlbad\30237\3 · permil\1 · exlerior signage 43' -9" 6'-3" 2'-4 3/4" □ WR KITCHEN & BAR -------------------------____________________________ l _____ _ ½ ,----7 I I tE □ . I I ' ~ I I ½ I I I I I I I I ½ I I I I Client: Project: Revisions: Projecl No: 30237-R06 (PSl WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad ~ RT, 10.21.19-dinumsions odded to show spacing betoeen lines of copy This is an original unpublished drawing created by AD/S Inc. II is 2019-08-20 submitted for your pmonal use in conjunction wilh a project being Dale: MS/JMIT c/o Wood Ranch USA Inc. Caporale Offices 2668 Gateway Rd. Suite 170 l_, RT: 10.23.19-Sign B updoted to holo•illuminotion planned for you by AD/S Inc. II is nol lo be shown lo anyone outside 2835 Townsgote Rd. Suite 200 Carlsbad, CA 92009 J:.. RT: 1014.19-Sign A: olum panel revised lo orchitecturol element your organizalion, nor is ii to be used, reproduced, copied or Sign Type Sign C Westlake Village, CA 91361 exhihiled in any fashionwilhoul written per111ission from AD/S Inc. Sheel No: C.10 80111 ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' BY Area of banner 7'-6" WOOD 30.0 sq. ft. RANCH @ 13oz. White banner; Digitally printed to match colors shown Banner to be hemmed with grommets. 0 :_ --------------------------------------------------------------------------------o ·---------------------------------------------------------------------o ffl~ 1160 Railroad St. ■ S ignage + Fabrication Client: Project: Revisions: Corona, CA 92882 WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad ' T 800.862.3202 ■Displays+ Fixtures fu Rl 10.21.19-dimensions odded lo show sporing between lines of ropy F 951.278.0681 ■Lighting + Maintenance c/o Wood Ronch USA Inc. Coporote Offices 2668 Gateway Rd. Suite 170 ...f... Rl 10.23.19-Sign B updoted to holo-iltuminolion ■ ■ ■ www.ad-s.cam 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 91361 __L RT: 10.24.19-Sign A: olum ponel revised to orchitectural element file path: G.\ADS Drawings\Wood Ranch 880 & 6rill\WR Carslbad\30237\3 • pmtit\2 • exterior signage Project No: 30237-R06 IPS) This is an original unpublished drawing created by AD/S Inc. It is Date: 2019-08-20 MS/JK/RT submitted for your personal use in conjunction with a project being planned for you by AD/S Inc. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or Sign Type: Sign D eihibited in any lashion without written permission lrom AD/S Inc. Sheet No: 0.00 9 of 12 STATE OF CALIFORNIA SIGN LIGHTING CEC-NRcc.t.TS-01·FIR~ 08/18) CALIFORNIA ENERGY COMMISSION 111 I CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E I Sign Lighting I """"""'"' Wood Ranch Kitchen & Bar -Carlsbad (Page 1 of S) 1--10-23-19 A. General Information Project Address: 2668 Gateway Rd. Suite 170 Carlsbad, CA 92009 Locattc>n of Sign ~ Outdoor Signs D Indoor Signs Phase of Sign Construction [i!'NewSigns 0 Sign Alterations I!( Not lnstallinR Lillhtine Controls Tvoe of Uahtina. Control D New Lighting Controls D Replaced Uriltin.11 Controls This Certificate of Compliance includes the following components (check all that appty): 0 Mandatory Measures (Lighting Controls) D Maximum Allowed Lighting Power I!( Specific lighting Sources 1. Mondatory Sign Lighting Controls NOTES: l. The same responsible person may install both the sign lighting power and the sign lighting controls, or a different responsible person may install the sign lighting controls than the responsible person installing the sign lighting power. 2. The Mandatory Measures (sign lighting controls) are required for compliance with the sign lighting Standards. If the person responsible for installing the sign lighting power is not also responsible for the sign lighting controls, then the owner of the sign, general contractor, or architect shall be responsible to hove the sign lighting controls installed. 3. If more than one person has responsibility for compliance, each responsible person shall prepare and sign a Certificate of Compliance and on Installation Certificate applicable to the portion of construction for which they ore responsible; alternatively~ the person with chief responsibility for construction shall prepare and sign the Certificate of Compliance Declaration Statement for the entire construction (e.g. a C-10 contractor moy complete parts la and lb on one compliance document and a C-45 contractor may complete parts 2a and 2b on a separate compliance document -the Responsible Designer shall submit the two compliance documents toqether for the some complete installation). I have responsibility for installing: the sign lighting controls: D Yes, I have responsibility for the sign lighting controls, and will l2f No, I do not have responsibility for Installing the sign lighting controls. complete parts l a and lb of this compliance document Someone else will complete parts la and lb of this compliance document. la. Check Yes or No for all of the lollowin• statements: 1 There are existing sign lighting controls that comply with the applicable provisions of §110.9 and §130.3 O fu n~ There are no existing sign lighting controls and I will be installing sign lighting controls that compty with the applicable 2 provisions of §110.9 and §130.3 O ves 0 No There are existing sign lighting controls that do not comply with the applicable provisions of §110.9 and §130.3 and I will be 3 installing sign lighting controls that comply with the applicable provisions of §110.9 and §130.3 0 fu □~ STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCCLTS-01 Re"Ased08/18 CALIFORNIA ENERGY COMMISSION Iii CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign lighting (Page 2 of S) ,_.-. Wood Ranch Kitchen & Bar -Carlsbad 10-23-19 lb. Mandotory Sien Uehling Controls If the person signing the Certificate of Compliance Declaration Statement on this NRCC-l TS-01-E is responsible for complying with the siR.n lighting control requirements, that person shall answer all of the following questions: If there are construction documents, indicate where on the building plans the I mandatory measures (sign lighting control} note block can be located: §130.3(a)l. All indoor si&n ll1hting is controlled with an automatic time-switch control or astronomical time-y N NA 1 switch control. 0 0 0 §130.3(a)2A. AU outdoor sign lichtlng: is controlled with a photocontrol in addition to an automatic time• y N NA switch control, or an astronomical time-switch control. 0 0 0 2 EXCEPTION to Section 130.3(a)2A; Out door signs in tunnels, and signs in large permanently covered outdoor y NA areas that are intended to be continuously lit, 24 hours per day and 365 days per year. 0 0 §130.3(a)2B. All outdoor sign llchtlng that is ON both day and night is controlled with a dimmer that provides the ability to automatically reduce sign lighting power by a minimum of 65% during nighttime hours. Signs that y N NA 3 are illuminated at night and for more than 1 hour during daylight hours shall be considered ON both day and 0 0 0 night. EXCEPTION to Section 130.3(a)28: Outdoor signs in tunnels and large covered areas that are intended to be y NA illuminated both day and ni•ht. 0 0 §130.3(a)3. Demond Responsive Electronic Message Center control. An Electronic Message Center (EMC) y N N/A having a new connected lighting power load greater than 15 kW has a control installed that is capable of 0 0 0 4 reducinll the liRhtinl power by a minimum of 30% when receivinll a demand response si.11nal. EXCEPTION to Section 130.3(a)3: Lighting for EMCs that is not permitted by a health or life safety statute, y NA ordinance, or reaulation to be reduced by 30%. 0 0 Field Inspector Notes: CA Building Energy Effidency Standards· 2016 Nonresidential Compliance August 2016 ffl~ 1160 Roilrood St. ■ Si gnoge + Fo b r icotion Clienl: Projecl: Corono, CA 92882 WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad T 800.862 .3202 ■ Dis plays+ F i xtur e s c/o Wood Ranch USA Inc. Coporote Offices F951 .278.0681 ■L i g h t ing+ Mointenonce 2668 Gateway Rd. Suite 170 ■ ■ ■ www.ad-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 91361 lile path: G:\AO S Orawings\Wood Ranch 8 80 & Grill\WR Carslbad\30 237\3 · pm1it\2 · ex1e1i or signage STATE OF CALIFORNIA CALIFORNIA ENERGY COMMISSION ■ SIGN LIGHTING CEC NRCCU S-01 E(Revlsed 08/16) CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting (Page 3 of 5) Project.Name: Wood Ranch Kitchen & Bar -Carlsbad I Dilte Prepa~: 10-23-19 2. Mandatory Sign Lighting Measures I have responsibility for installing the sign lighting @ Yes, I have responsibility for the sign lighting, and will complete D No, I do not have responsibility for installing the sign lighting. Someone parts 2a and 2b of this compliance document else will complete parts 2a and 2b of this compliance document. 2a. Maximum Allowed Lighting Power Method of Compliance Certificate of Compliance and Field Inspection Energy Checklist. Complete this part if there are signs using the maximum allowed lighting power method of compliance. (Complete part 2b of this Certificate of Compliance if there are signs using the Specific Lighting Sources method of compliance). A B C DE F G H I J Symbol or Code A B C D G H Description of the Sign OPTIONAL- Energy Verified Label (see instructions below) ✓ □ □ □ □ □ □ □ □ □ □ □ □ □ □ 1=. .. ~ < C bO vi Allotted Watts Symbol or code used on the plans (when plans are required) and other documents. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Design Watts Complies Y/N I.!) VI ::t: -~ .!!! Q. E 0 u A description of the sign, or location of sign on the building; and the location of sign on construction documents. Field Inspector Check that Sign Complies ✓ □ □ □ □ □ □ □ □ □ □ □ □ □ □ OPTIONAL -Check this box only if this sign has a permanent, pre-printed, factory-installed, ENERGY VERIFIED label, confirming that the sign complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the Maximum Allowed Lighting Power method of compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories (UL) or other Product Certification Body accredited to ISO/IEC Guide 6S by the American National Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, columns 'D' through 'I' are not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance. The siRn area in square feet. List •1• if the sign is internally illuminated. List "E" if the sign is externally illuminated. Allowed watts per square foot. Enter 12 if the sign is listed as •1• in column E. Enter 2.3 if sign is listed as "E" in column E. Multiply the square footage in column D times the allowed Lighting Power Density (LPD = watts) in column F. Show the total installed watts in the sign, as determined according to the applicable provisions of §130(c). Enter Y if the number in column H is less than or equal to the number in column G. Otherwise, the sign does not comply. This page doubles as a field inspection checklist. field Inspector Notes: CA Building Energy Efficiency Standards -2016 Nonresidential Compliance August 2016 Revisions: Project No. A 41 RT: 10.21.19 -dimensions added lo show spacing between lines ol copy This is an onginal unpublished drawing crealed by AD/S Inc. It is submitted for your personal use in conjunction with a project being Date: 5' ~ RT: 10.23.19 -Sign 8 updated to holo-illuminotion planned for you by AO/S Inc. It is not lo be shown to anyone oulside your organi1a1ion, nor is it lo be used, reproduced, copied or Sign Type: lL RT, 10.24.19 -Sign A, olum panel revised lo orchiledurol elemenl eihibited in any fashion withoul written permission fromAO/S Inc. Sheet No. 30237-R06 (PS) 2019-08-20 MS/JK/Rl Title 24 T24.00 10 of 12 STATE OF CALIFORNIA SIGN LIGHTING CEc-NRCC·L TS.01-E(Revised 08/16) CALIFORNIA ENERGY COMMISSION ■ STATE OF CALIFORNIA SIGN LIGHTING CEc-NRCC-LTS.01·E(Revised 08/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC·LTS-01-E CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting {Page 4 of 5) Sign Lighting (Page 5 of 5) Project Name: Wood Ranch Kitchen & Bar • Carlsbad I Date P~pared: 10-23-19 ProjectN;1me: Wood Ranch Kitchen & Bar • Carlsbad I Date Prepar~: 10-23-19 2b. Specific Lighting Source Method of Compliance DOCUMENTATION AUTHOR'S DECLARATION STATEMENT Certificate of Compliance and Field Inspection Energy Checklist 1. I certify that this Certificate of Compliance documentation is accurate and complete. Complete this part if there are signs using the Specific Lighting Source method of compliance. (Complete part 2 of this Certificate of Compliance if there are signs using the maximum allowed lighting power method of compliance) A B C D E Documentation Author Name: Documentation Author Signat~ Barbara Cohen Company: Signature Date: ~ Architectural Design & Signs 08-20-19 OPTIONAL ENERGY Specific light source used for Field Inspector Symbol VERIFIED compliance or Description label Shall include only lighting Check that Sign Code (see technologies listed below Complies ✓ instructions (List all that apply) Address: CEA CertifJCation ldentrfication (if applicable): 1160 Railroad Street Clty/State/Zip: Phone: Corona, CA 92882 (951) 278-0680 X 124 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California; 1. The information provided on this Certificate of Compliance is true and correct. below) 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified A Halo-Illuminated Channel Letters □ 7 □ B Halo-Illuminated Channel Letters □ 7 □ on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of ntle 24, Part 1 and Part 6 of the California Code of C Halo-Illuminated Channel Letters □ 7 □ Regulations. □ □ □ □ 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. □ □ □ □ □ □ A Symbol or code used on the plans (when plans are required) and other documents. 8 A narrative description of the sign, or location of sign on the building; and the location of sign on construction documents 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the b~j!lling owner at occupancy. Responsible Designer Name: Responsible Designer Signature: //JI/If\ Milton Solomon Company: Date Signed: 1/V Architectural Design & Signs 10-23-19 OPTIONAL· Check this box only if this sign has a permanent, pre-printed, factory-installed ENERGY VERIFIED label, confirming that this sign complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the Specific Lighting Source Method of Compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories C (UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National Standards Institute in accordance with 150/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A Address: License: 1160 Railroad Street 714309 Clty/State/z;p: Phone: Corona, CA 92882 (951) 278--0680 x122 Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, column 'D' is not required to be filled out. Note; Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance. Specific Light Source Compliance Method. The sign(s) identified above use only the following lighting technologies, List all applicable numbers (1 through 9) that apply in column D above for each row. 1 High pressure sodium lamps Metal halide lamps that are pulse start or ceramic served by a ballast that has a minimum efficiency of 88% or greater. 2 Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when tested accord ing to ANSI C82.6-2005. Metal halide lamps that are pulse start that are 320 watts or smaller, are not 250 watt or 175 watt lamps, and are 3 served by a ballast that has a minimum efficiency of 80%. Ballast efficiency is the measured output w attage to t he lamp divided by the measured operating input wattage when tested according to ANSI C82.6-2005. D Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 75% when 4 the transformer or power supply rated output current is less than 50 mA. The ratio of the output wattage to the input wattage is at . 100% tubing load. Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 68% when 5 the transformer or power supply rated output current is 50 mA or greater. The ratio of the output wattage to the input wattage is at 100% tubing load. 6 Fluorescent lighting systems meeting one of the following requirements; A.) Use only lamps with a minimum color rendering index (CRI) of 80; or 8.) Use only electronic ballasts with a fundamental output frequency not less than 20 kHz. 7 Light emitting diodes (LEDs) with a power supply having an efficiency of 80% or greater. Single voltage external power supplies that are designed to convert 120 volt AC input into lower voltage DC or AC output, and have a 8 nameplate output power less than or equal to 2SO watts, shall comply with the applicable requirements of the Appliance Efficiency Regulations (Title 20). 9 Compact fluorescent lamps that do not contain a medium screw base sockets (E24/E26). E This page doubles as a field inspection checklist. Field Inspector Notes; CA Building Energy Efficiency Standards -2016 Nonresidential Compliance August 2016 CA Building Energy Efficiency Standards -2016 Nonresidential Compliance August 2016 IJ~ I 160 Roilrood St. ■ Sign age + Fobricotion Clienl: Project Revisions: Projecl No. 30237-R06 (PS) Corona, CA 92882 WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad '\ T 800.862.3202 ■Displays+ Fixtures ~ RT: l 0.21.19-dimensions odded lo show spacing between lines ol copy This is an original unpublished drawing crealed by AD/S Inc. It is 2019-08-20 c/o Wood Ranch USA Inc. Coporate Offices 2668 Gatewoy Rd. Suite 170 sub11itted for your personal use in conjunction willl a projecl being Dale: MS/JJJRT F 951.278.0681 ■Lighting+ Mointenonce .1.. RT: 10.23.19-Sign B updated to holo-illuminotion planned for you by AO/S Inc. II is nol lo be shown to anyone oulside ■ ■ • www.od-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your organization, nor is ii 10 be used, reproduced, copied or Sign Type: Title 24 Westlake Village, CA 9136 l j_ RT: 10.24.19 -Sign A: alum panel revised to orchitecturol elemenl exhibited in any fashion withoul written permission fromAO/S Inc. file path: 6:\AOS Drawi ngs\Wood Ranch 880 & Grill\WR Cars Iba d\J 02 37\J . permil\2. exlerior signage Sheet No. T24.l0 11 of 12 STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCI-LTS-01-E (Revised (01/16) CALIFORNIA ENERGY COMMISSION. STATE OF CALIFORNIA SIGN LIGHTING CEC-NRCI-LTS-01-E (Revised (01/16) CALIFORNIA ENERGY COMMISSION • CERTIFICATE OF INSTALLATION NRCI-L TS-O1-E CERTIFICATE OF INSTA LLATION N R C I-LTS-O1-E Sign Lighting Page 1 of 2 Sign Lightin g Pag e 2 of 2 Project Name: Wood Ranch Kitchen & Bar -Cartsbad Enforcement Agency: Permit Number: Project Name: Wood Ranch Kitchen & Bar -Cartsbad Enforcement Agency: Permit Number: ProjectAddress: 2668 Gateway Rd. Suite 170 City: Carlsbad Zip Code: 92009 ProjeclAddress: 2668 Gateway Rd. Suite 170 City: Carlsbad Zip Code: 92009 GENERAL INFORMATION DOCUMENTATION AUTHOR'S DECLARATION STATEMENT DATE OF PERMIT: PERMIT NUMBER: 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: LOCATION OF SIGN(S ): □ Outdoor Sign(s) □ Indoor Sign(s) Documentation Author Company Name: Date Signed: PHASE OF CONSTRUCTION: □ New Sign(s) □ Sign Alteration Address: CEA Certification Identification (If applicable): SCOPE OF RESPONSIBILITY City/State/Zip: Phone: Enter the date of approval by enforcement agency of the Certificate of Compliance that provides the specifications for the energy efficiency measures for the scope of responsibility for this Installation Date: RESPONSIBLE PERSON'S DECLARATION STATEMENT Certificate. I certify the following under penalty of perjury, under the laws of the State of California: 1. The infonnation provided on this Certificate of Installation is true and correct. In the table below identify all applicable construction documents that specify the requirements for the scope of responsibility 2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the reported by this Installation Certificate (continued). system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work Document Title or Description Applicable Sheets or Pages, Tables, Date Approved by Schedules, etc. Enforcement Agency identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. I reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. I will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building pennit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (Title): Address: CSLB License: City/State/Zip: Phone I Date Signed: CA Building Energy Efficiency Standards -2016 Nonresidential Compliance January 2016 CA Building Energy Efficiency Standards -2016 Nonresidential Compliance January 2016 ffl~ 1160 Railroad St. ■ Signoge + Fabrication Client: Project: Revisions: Project No: 30237-R06 (PS) Corona, CA 92882 ■Di splays + Fixtur es WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad This is an original unpublished drawing created by AD/S Inc. It is T 800.862.3202 ,...h RI 10.2l.l9-dimensions odded to show spacing between linei of copy 2019-08-20 submitted for your personal use in conjunction with a project being Date: MS/JI/RT f 951.278.0681 ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Coporate Offices 2668 Gateway Rd. Suite 170 ...'.L Rl 10.23.19-Sign B updated to halo-illumination planned for you by AO/S Inc. It is not to be shown to anyone outside ■ ■ • www.ad-s.com 2835 Townsgate Rd. Suite 200 Carlsbad, CA 92009 your organization. nor is it to be used, reproduced, copied or Sign Type: Title 24 Westlake Village, CA 91361 _6~ RI 10.24.19 -Sign A, alum panel revised to architectural element exhibited in any fashion without written permission from AO/S Inc. file path: 6:\AOS O rawings\Wood Ranch BBQ & 6rill\WR Cars Iba d\30137\3 • permit\1 · exterior signa ge Sheet No: 124.20 11 ol 11 Checklist: '111 1160 Railroad St. ■ Sig noge + Fabrication Clienl: Project: Corona, CA 92882 WR Kitchen & Bar Carlsbad WR Kitchen & Bar -Carlsbad ■Displays+ Fixtures T 800.862.3202 F 951 .278.0681 ■Lighting+ Maintenance c/o Wood Ranch USA Inc. Coporote Offices 2668 Gateway Rd. Suite 170 ■ ■ ■ www.ad-s.com 2835 Townsgote Rd. Suite 200 Carlsbad, CA 92009 Westlake Village, CA 91361 Iii e path: 6:\AOS Orawi ngs\Wood Ranch 8 BO & Grill\WR Carslbad\302 3713 • permit\2 · uteri or signage Summary of outstanding issues (TBD ite ms): remove items from this list o information is received & integrated l) Sign C. l -missing thing-a-mo-jig to be provided 2) Sign L. l -waiting on point color from client 3) Sign M. l -waiting on vector artwork from client Summary of Revisions: Rev # & hrs s ent: Rev 01: 2.5 hrs Po e: Demi tion: Revisions: \ I 4 RI 10.21.19 -dimensions added ta shaw spacing between lines of copy .l.., RI 10.23.19 -Sign 8 updoted ta halo-illumination ' ....!_. RI 10.24.19-Sign A, olum panel revised to orchitecturol elemenl Project No: 30237-R06 (PS) This is an original unpublished drawing created by AO/S Inc. It is Date: 2019-08-20 submitted for your personal use in conjunction with a project being planned for you by AO/S Inc. It is not to be shown to anyone outside Checklist / TBD Tally your organization. nor is it to be used, reproduced, copied or Sign Type: exhibited in any fashion without written pennissionfro11 AO/S Inc . Sheet No: Cll.10 MS/JK/HT 13 of 11