Loading...
HomeMy WebLinkAbout6172 GATEWAY RD; ; FPC2018-0232; PermitPERMIT REPORT C(City of Carlsbad Print Date: 10/19/2021 Permit No: FPC2018-0232 Job Address: 6172 GATEWAY, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel if: Track if: Applied: 07/30/2018 Valuation: $0.00 Lot if: Issued: Occupancy Group: Project if: DEV12023 Finaled Close Out: 07/29/2021 #of Dwelling Units: Plan if: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check if: Inspector: Plan Check if: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI - UNDERGROUND BLDG #4 Applicant: FPContractor: CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION GONZALO PENA 8361 COMMONWEALTH AVE 8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525 BUENA PARK, CA 90621-2525 (714) 912-4552 (714) 912-4552 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $625.00 Total Fees: $625.00 Total Payments To Date: $625.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov - - - Fire Protection by Computer Design Cal-West Fire Protection 1113 N Gates St. Santa Ana, Ca. 92703 866-374-9378 Job Name : Uptown Bressi "Bldg. #4" Building Location El Fuerte St. & Gateway Rd. System Contract : 18-099 Data File : Bldg. - 4.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cal-West Fire Protection Page 1 Uptown Bressi Bldg. #4" Date 7.19.18 City Water Supply: Demand: Cl -Static F5ressure : 100 Dl - Elevation : 1.516 C2 - Residual Pressure: 20 D2 - System Flow : 500 C2 - Residual Flow : 2500 D2 - System Pressure : 15.387 Hose ( Demand) D3 - System Demand : 500 Safety Margin : 80.539 150 140 130 p120 R° E100 -. 890 80 u 70 R 60 E 50 40 - 30 20 —02 10 30 r600900 1200 1500 1800 2100 2400 2700 FLOW( N ' 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cal-West Fire Protection Page 2 Uptown Bressi "Bldg. #4 Date 7.19.18 Fitting Legend Abbrev. Name Y2 % 1 1% 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Cal-West Fire Protection Page 3 Uptown Bressi Bldg. #4 Date 7.19.18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. BOR 0.5 0.0 na 500.0 UG1 -3.0 2.89 na UG2 -3.0 4.81 na UG3 -3.0 13.4 na SRC -3.0 15.39 na The maximum velocity is 12.15 and it occurs in the pipe between nodes UG2 and UG3 Computer Programs by Hydratec Inc. Revision: 50.52.1 4 Final Calculations - Hazen-Williams Cal-West Fire Protection Page 4 Uptown Bressi "Bldg. #4" Date 7.19.18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 500.00 4.26 E 13.167 12.000 0.0 Qa = 500.00 to 120.0 0.0 13.167 1.516 UG1 500.0 0.0545 0.0 25.167 1.372 Vel = 11.25 UG1 0.0 4.23 2E 38.446 13.000 2.888 to 150.0 0.0 38.446 0.0 UG2 500.0 0.0373 0.0 51.446 1.921 Vel= 11.42 UG2 0.0 4.1 3E 49.537 10.000 4.809 to 150.0 Zif 0.0 49.537 6.000 * * Fixed Loss = 6 UG3 500.0 0.0435 0.0 59.537 2.588 Vel = 12.15 UG3 0.0 4.23 G 3.845 11.000 13.397 to 150.0 T 38.446 42.290 0.0 SRC 500.0 0.0373 0.0 53.290 1.990 Vel = 11.42 0.0 500.00 15.387 K Factor = 127.47 Computer Programs by Hydratec Inc. Revision: 50.52.1 A-2102 Wafer Check Valve 4 9 6, 811 175 psi (1207 kPa) Working Pressure 350 psi (2413 kPa) Test Pressure Listed by Underwriters Laboratories, Inc. and Approved by Factory Mutual Research Corporation. PARTS LIST Catalog Parts Description Number Material Material Standard CW-1 Seat Ring Cast Bronze ASTM B584 CW-2 Body Cast Iron ASTM A126 CW-3 0-Ring (2 req'd) Buna-N ASTM D2000 CW-4 Clapper Cast Bronze ASTM B584 CW-5 Bushing (2 reqd) Brass ASTM B16 CW-6 Spring Stainless Steel Type 302 CW-7 Hinge Pin Stainless Steel Type 303 CW-8 Seal, Seat EP Rubber ASTM D2000 C.1 WAFER CHECK VALVES Rev. 2-03 IMueller Ca.1 UL /FM FIRE PROTECTION PRODUCTS DIMENSIONAL INFORMATION FOR WAFER CHECK VALVES Size DIMENSIONS In. A (mm) In. B (mm) C In. (mm) In. D (mm) In. E (mm) 4 3.75 (95) 1.34 (34) 6.88 (175) 3.00 (76) 4.03 (102) 6 3.75 (95) 1.53 (39) 8.75 (222) 4.56 (116) 6.06 (154) 8 1 4.25 (108) 1 1.92 (49) 11.00 (279) 6.00 (152) 7.98 (203) WAFER CHECK VALVE ORDERING INFORMATION WAFER CHECK VALVE WEIGHTS Specify: Quantity, Size and Catalog Number. WAFER CHECK VALVE PARTS ORDERING INFORMATION Specify: Quantity, Catalog Number, Part Name, Size of Valve, La1aIog iumuer 01 vaive and rear uate 01 valve. - -- Page C-1-6 4 6 8 Lb 15.75 22.50 36.50 Kg 7.14 10.21 16.56 0 No. 135 E) CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Sprouts Farmers Market SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 6217 El Fuerte St CITY: Carlsbad PHONE: ( 714) 914-4552 (Cal-West Fire) FAX NUMBER: ( 714 ) 912-4641 Largest Building (ft.2): 26.000 Sprinkled? Yes Construction Type: LINK SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable):H20910 Elevation of test: 402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet Date/Time of Test: Pitot Tube Reading PSI Corresponding Flow:GPM Total Flow: 8,000 GPM Residual Pressure 110 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer_R.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:_________________________________________ / Title/Org;diectManager Date: 01/11/2018 / JO ç.I I I/s I I I N + Legend I wHydrant Pipe ZONE 8 -550 -700 4 cP eL 12 tl % 7"WY L*RTINGT n AMMEDA CR L HANCOCKCR4 H LENRD Sprouts Farmers Market - Fire Flow Analysis MJ Accessories ANSI/AWWA C111/A21.11 O.D. B.C. -I I I I BA I FULLBODY GLANDS NOM. O.D. B C I.D.B.C.OLT BOLT WT SIZE HOLE QTY (LBS.) 2 6.12 0.62 1.18 3.40 2.61 4.75 00.75 2 1 3 7.69 9.12 0.62 0.75 1.37 1.50 4.84 5.92 4.06 4.90 6.19 7.50 00.73 00.88 4 4 5 6 4 6 11.12 0.88 1.63 8.02 7.00 9.50 00.88 6 10 8 13.37 1.00 1.75 10.17 9.15 11.75 00.88 6 14 10 1562 100 17 1222 1120 1400 0088 8 20 12 17.88 1.00 1.75 14.32 13.30 16.25 00.88 8 24 14 20.25 1.25 2.00 16.40 15.44 18.75 00.88 10 45 1.31 21.00 16 22.50 2.06 18.50 17.54 00.88 12 55 18 2475 138 213 2060 1964 2325 0088 12 55 20 27.00 1.44 2.19 22.70 21.74 25.50 00.88 14 66 24 31.50 1.56 2.31 26.90 25.94 30.00 00.88 16 90 30 39.12 2.00 2.75 33.29 39.59 32.17 38.47 36.88 43.75 01.13 01.13 20 24 220 286 36 46.00 2.00 2.75 42 53.12 2.00 2.75 45.79 44.67 50.62 01.38 28 288 48 6000 200 275 5209 5097 5750 0138 32 400 jig _:_rjr' M UCAT.I4,OI REGISTERED TRADEMARK OF STAR FIFE PRODUCTS STAR FIFE PRODUCTS 471 HOUSTON CORPOIATETOLL FREE 1.800.9993(4)9FAX 281 - dl )8.9000 Page 15 JMagIe Building essentials for a better tomorrow PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 12 13.20 12.08 0.528 8.80 15.31 14.4 PRESSURE CLASS 235psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 1 0.733 1 8.80 16.13 1 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 13.20 11.20 0.943 8.80 16.97 25.1 Consult JIM Eagle" for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. * Contact your JIM eagleTM sales representative for location availability. I.D. Inside Dameter O.D. Outside Diameter T. : Wall Thickness D9 Bell Outside Diameter I.D. E: Distance between Assembly Mark to the end of spigot. D9 1 T / 1 O.D. E I __________I Assembly Mark Product Standard: ANSI/AWWA C900 Pipe Compound: ASTM D1784 Cells Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length Installation: AWWA C605 JIM Eagle* Installation Guide JM EagleTM also manufactures this pipe in green for sewer force main applications and purple, specifically for reclaimed water systems. This pipe is made to the same requirements as our standard products. The only difference is that the pigment used is green or purple. These products will not be marked with UL or NSF listing marks. Additionally, the green pipe will be marked "Forced Sewer" and the purple pipe will be marked: "Reclaimed Water... Do Not Drink." For Non-Health Hazard Applications Job Name Contractor Job Location Approval Engineer Contractors P.O. No. Approval Representative MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 21/211 - 8" (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backfiow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4" Backfiow Assembly No Special Tools Required for Servicing Field Replaceable Seats & Discs Tt Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AWINA Standard C510. The auxiliary bypass line contains a %")0/4' Water Meter that complies with ANSI/A\MNA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWvVA Standard C51 0 flow and pressure loss performance parameters. NOTICE I The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. —(,1tt,1— Inquire with governing authorities for local installation requirements Detect Potential Underground Water Leaks "The wetted surface of this product contacted by consumable Detect Unauthorized Water Usage water contains less than 0.25% of lead by weight. AMMMMONNEEMMMMEMENNEW Z~~S~C~Z7~ FEBCO product specifications in U.S. customary units and metric are approximate and are prodded for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A W41S Brand Options - Suffix OSY: UL'FM Approved OS&Y Gate Valves [ANSI/A\MNA C515 Compliant] CFM: Totalizing Cubic feet/mm %'x 3/4' Water Meter [ANSI! AWWA C700 Compliant] GPM: Totalizing Gallons/mm 5/8'x 3/4' Water Meter [ANSI! AWINA C700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4' LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer: FDA Approved [ASME B16.1 Class 125 & AWINA Class D Range] Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical Joint [AWWAC111!A21.11] MJ x FL - Mechanical Joint x Range [AWiNAC111/A21.11;ASMEB16.1 Class 125!A\MNA Class D Range] FL x FL - Flange x Flange [ASME B16.1 Class 125 &AW\NA Class D Range] Materials Below is a genera] materials list of the Model LF876V All assemblies size 21/2 ' through 8" is similar in materials and construction. Please contact your local FEBCO Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external A\MNA C550-90 Shutoff Valves: OSY resilient wedge gate valve AW\NA C515 PL/FM Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc: Silicone Spring: Stainless Steel Clamp: AWA C606 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [FCCCHR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO!cUPC AWiNA Standard C510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & AVVWA Class D Range **Assembly configured with U[JFM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2 ' - 8') - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattern 21/2" - 8") - Approved by FCCCHR-USC, ASSE, cULus, FM, lAPMO/cUPC ILIA F. ® <e:; ssIP4; G Approved C ®US 1048 864.5 Pressure - Temperature Max. Working Pressure: 175psi (12.1 bar) Min. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350ps1 (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous 1 Dimensions - Weights Size: 21/211 - 8" Below are the nominal dimensions and physical weights for the Model LF876V size 21/2 through 8 . PJlowances must be made for normal manufacturing tolerances. Please visa our websfte to download a copy of this products installation instnjctions, or contact your local FEB00 Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE(DN) -- DIMENSIONS WE1GHT in. mm in. A mm B in. mm in. C mm 0 in. mm E in. mm F in. mm G in. mm in. H mm I in. mm J in. mm K in. mm I in. mm OSY lbs. kg. 21/2 65 291A 740 121/2 318 61/4 159 251/4 642 171/2 445 135A 346 271/4 692 51/2 140 11'/8 283 31/2 89 163's 416 11½ 292 216 98 3 80 291/8 740 121/2 318 61/4 159 251/4 654 17Y4 451 141/8 359 281/4 718 51/2 140 11'/8 283 3Y4 95 221/4 565 11112 292 242 110 4 100 31½ 791 14 356 7 178 27Y4 705 18Y4 476 151/2 394 31 787 1 6 152 111/8 283 41/2 114 231/4 591 13 330 347 157 6 150 351/4 908 16 406 8 203 32Y4 831 221/8 562 1 181A 473 371A 946 7¼ 184 121/2 316 51/2 140 301/8 765 13 330 529 240 8 200 40/i 1035 181/2 470 91/4 235 363/4 933 25Y8 638 203/4 527 1 411/2 1054 81/2 216 14 356 6N 172 373/4 959 1 141/2 368 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backtlow Assemblies with specified Gate Valves 6" LF876V psi Service Flaw Rated Flow *UL Rated Flaw 18 16 14 9 12 10 Vi U 8 6 0 200 400 600 800 1000 1200 1400 1600 gpm 757 2,271 3785 5300 Ipm 7.5 11.4 17.0 fps 8" LF876V psi Service Flaw Rated Flow lii Rated Flaw 18 16 14 t 2 0 S 8 6 0 400 800 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps 4" LF876V psi 18 16 14 12 3 10 8 6 L_ N Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. A\AiWA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than lOfps. UL flow rate is determined by typicafly rated Velocity of 15 feet/sec. Capacity N-Pattern ern 2½" LF876V psi Service Flow Rated Flaw lii Rated Flaw 22 20 I I 18 i I I 16 I I 14 I C 12 I I 10 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350gpm 284 568 852 1135 IPM 7.5 14.7 22.0 fps 3" LF876V psi Service Flaw Rated Flaw *01 Rated Flow 22 20 I 18 8 16 14 09 V5 12 I 10 ttT 0 50 100 150 200 379 757 7.5 250 300 350 1136 14.5 400 450 500 gpm 1514 1pm 22.0 fps Pipe Support (furnished by customer) Al for valve weight only. Verbcal Orientaton Z-Patlem" Flow Curve z Standard Orientation N-Patlem Flow curie N 0 100 200 300 400 500 600 700 800gpm 379 1136 1893 2650 1pm 7.5 12.8 19.1 fps h%O~W A WATTS Brand ES-F-LF876V 1515 USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBcoonline.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBCOonline.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonline.com 0 2017 FEBCO ES-A-InBuildingRiser Series IBR Pk A M E S In-Building Risers FIRE Sizes: 4" - 10" (100— 250mm) = CAP 01 NOW Features Cost savings Corrosion resistant stainless steel construction, type 304 Ease of installation and light weight allows one person to position and handle the riser Minimal site preparation; joint restraint one-piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals Includes Test Cap and Coupler ULJFM approved Sizes: available in 4" - 10" (100-250mm) with various lengths to meet all local requirements Designed to meet NFPA 24-2007 Section 10.6.5 AWWA C900 Inlet/DIP Series lBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without joints and extends up through the floor. Provided with installation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA 24-2007, the ULJFM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel signifi- cantly increases the reliability and life of the riser. The wetted surface of this product contacted by consumable water contains less than one quarter AWWA C606 Outlet of one percent (0.25%) of lead by weight. Job Name Contractor Job Location Approval - Engineer Contractor's P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the tight to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration class 1920 HKQA (4-10') Specifications In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tub- ing, maximum working pressure 200psi (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a CIPS coupler on the inlet (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground piping. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. Approvals Fittings FM UL <6> S Dimensions - Weights A Grooved End f (Range Optional) J— li CIPS Coupling Tie-Rod Bracket C in. mm A(OD) in. mm B ft. cm C ft cm lbs. kg 4 100 41/2 114 6 183 6 183 71 32 6 150 65/8 168 6 183 6 183 98 44 8 200 1 85/8 219 6 183 6 183 129 59 10 250 1 103/4 273 1 6 183 1 6 183 1 202 92 Consult factory for custom leg dimensions. Standards NFPA - Designed to allow the contractor to conform to NFPA 24-2007 Section 10.6.5: Where a riser is close to building foundations, under- ground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. NFPA 24-2007, 10.1.1, 10.6.7 End Connections tM1W MATING IlPIPE I1' in. mm in. mm 4 100 4.8 122 6 150 6.9 175 8 200 9.1 230 10 250 11.1 282 Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-gao pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory SIZE •DESIGN J IPROOF PRESSURE in. mm psi bar 4 100 1000 70 6 150 1000 70 8 200 800 56 10 250 RUO 56 IMPORTANT: Inquire with governing authorities for local installation requirements. A AM ES FIRE &WATERWORKS www.amesfirewater.com 0 A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • T: 916-928-0123 • F: 916-928-9333 Control Valves- 18550 Hansen Road • Houston, TX 77075 • T: 713-943-0688 • F: 713-944-9445 Canada: 5435 North Service Rd. • Burlington, ONT. L7L 5H7. T: 905-332-4090 • F: 905-332-7068 ES-A-InBuiIdingRiser 0935 © 2009 Ames Fire & Waterworks PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF McWANE, INC. P.O. BOX 1219, PROVO, UTAH 84803 TELEPHONE (AREA CODE 801) 373-6910 STANDARDS In each of the following, standards are developed by committees consisting of consumer, general interest and manufacturing members: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) MH 16433(N) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) 61-1989 Factory Mutual (FM) J12VOA8.AH For ready reference, standards for ductile iron pipe are listed below: Standard Designation ANSI/AWWA C150/A21.50 ANSI/AWWA C1511A21.51 ANSI/AWWA C11O/A21.1O ANSI/AWWA C153/A21.53 ANSI/AWWA Cli 1/A21.11 ANSI/AWWA C1151A21.15 ANSI/AWWA C104/A21.4 ANSI/AWWA Cl 05/A21.5 & ASTM A674 ANSI/AWWA C600 ASTM A746 NFPA Outside Protection 24 Subject Covered Design Water Pipe Fittings - Cast Iron Fittings - Ductile Iron Rubber - Gasket Joints Flanged Pipe Cement - Mortar Linings Polyethylene Encasement for Ductile Iron Pipe Installation Gravity Sewers Fire Protection Piping Pacific States ductile iron pipe meets and exceeds the requirements of all of the above national standards relating to pipe manufacture and performance. PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF McWME, INC. P.O. BOX 1219, PROVO, UTAH 84603 TELEPHONE (AREA CODE 801) 373-6910 FAX: (801) 377-0338 EMAIL: salespscipco.com WEBSITE: www.pscipco.com Thickness, Dimensions and Weights of Mechanical Joint Ductile Iron Pipe by Size for Each Thickness. Nominal Wt. of Barrel Mechanical Joint Wt. of Wt. Per Avg. Wt. Thickness Thickness OD* Per Ft. t Bell Lgth.t Per Ft4 Size Class In. In. Lb. Lb. Lb. Lb. 3 53 .31 3.96 10.90 11 230 11.4 4 53 .32 4.80 13.80 16 290 14.6 6 53 .34 6.90 21.40 18 405 22.4 8 53 .36 9.05 30.10 24 565 31.4 10 53 .38 11.10 39.20 31 735 40.9 12 53 .40 13.20 49.20 37 925 51.3 tlncluding be)); calculated weight of pipe rounded off to the nearest 51b*Tolerances of OD of spigot end; 3-12 in. ±0.06 in. *Including be)); average weight per foot, based on calculated weight of pipe before rounding. Visit our website at www.kennedyvalve.com K KENNEDY VALVE A DIVISION OF MCWANE, INC I ASSOCIATED WITH AWWA, NSF AND ULFM C-509 FULL BODY CAST IRON RESILIENT WEDGE VALVE III During the decade of the 1980's, the waterworks industry was introduced to the Resilient Seated Gate Valve, a design principle that is dominant in preference for use in distribution systems. Kennedy Company was at the forefront in this industry-wide movement by introducing the Ken Seal Series, our AWWA C509 Resilient Seated Gate Valve. In 2002, with the end user in mind, Kennedy redesigned the Ken Seal Series introducing the model KS-FW. The goal of the redesign was to eliminate the customer need for any anti- rotational bolts. Kennedy did this by designing a machined elliptical bolthole in place of an as-cast opening. This elliptical design allows valve installers to slide a standard sized bolt into the slot, therefore eliminating the need to have two different types of bolts on the installation. RECOMMENDED SPECIFICATIONS FOR C-509 CAST IRON RESILIENT WEDGE GATE VALVES KENNEDY VALVE COMPANY Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves for all water supply service. The valves shall have a cast iron body, bonnet, and 0-ring plate. The wedge shall be totally encapsulated with rubber. The sealing rubber shall be permanently bonded to the wedge per ASTM D429. J. Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets shall be allowed. Blind bolts shall not be allowed. The valves shall be either non-rising stem or rising stem, opening by turning left or right, and provided with 2" square operating nut or a handwheel with the word "Open" and an arrow to indicate the direction to open. Stems for NRS assemblies shall be cast bronze with integral collars in full compliance with AWWA. OS&Y (rising stems) shall be bronze. All stems shall operate with bronze stem nuts independent of wedge and of stem (in NRS valves). Stainless stems are available but not standard. NRS stems shall have two 0-rings located above thrust collar and one 0-ring below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full pressure. The NRS stems on 2"-12" shall also have two low torque thrust bearings located above and below the stem collar to reduce friction during operation. Waterway shall be smooth, unobstructed and free of all pockets, cavities and depressions in the seat area. Tapping valves 4" and larger shall accept a full size tapping cutter. The body, bonnet, and 0-ring plate shall be fusion-bond epoxy coated, both interior and exterior on body and bonnet. Epoxy coating shall be NSF 61 certified and applied in accor- dance with AWWA C550. Each valve shall have manufacturers name, pressure rating, and year in which it was manu- factured cast in the body. Prior to shipment from the factory, each valve shall be tested by hydrostatic pressure equal to the requirements of AWWA C-509 (and UL/FM where applicable). Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the Kennedy Valve Company. (Revised 03-27-2011) I.1tLF4I. 1a 11 .i4tIP DELRIN THRUST BEARINGS ABOVE AND BELOW THE THRUST COLLAR REDUCE FRICTION AND MINIMIZE OPERATING TORQUES LONG, TROUBLE FREE LIFE WITH HIGH STRENGTH, NON-CORRO- SIVE BRONZE STEM AND STEM NUT. ALL NRS STYLE VALVES ARE STAIN- LESS THE OPERATING MECHANISM IS TRIPLE 0-RING SEALED TO COMPLETELY SEAL AGAINST LEAKAGE PAST THE STEM. TWO 0-RINGS ARE PROVIDED ABOVE THE THRUST COLLAR AND ONE BELOW. UPPER 0-RINGS CAN BE REPLACED UNDER PRESSURE WITHOUT REMOVING THE STEM WHEN THE VALVE IS FULLY OPENED. 0-RING SEALS AT STUFFING BOX AND BONNET TO BODY FLANGES TO ENSURE THE BEST POSSIBLE SEAL. NO FLAT GASKETS. 100% EPDM COATED WEDGE WITH TWIN SEAL DESIGN ENSURES BUBBLE- TIGHT SEAL UP TO 250 PSI EVERY TIME. ELLIPTICAL BOLT HOLE DESIGN ELIMINATES THE NEED FOR ANTI-ROTATION BOLTS KENNEDY CORROSION RESISTANT FUSION- BONDED EPDXY COATING, CONFORMING TO AWWA 0.550 AND NSF61 CERTIFIED, PROTECTS BOTH INSIDE AND OUTSIDE OF VALVE. SMOOTH, UNOBSTRUCTED PADS ON THE BOTTOM OF FULL SIZE WATERWAY IS ALL VALVES KEEP VALVE FREE OF POCKETS, CAVI- IN UPRIGHT POSITION TIES, AND DEPRESSIONS FOR EASIER STORAGE ALLOWING FOR MINIMAL AND PROTECTION FROM FLOW LOSS AND LOWER THE ELEMENTS. PUMPING COSTS. ALL TAPPING VALVES ACCEPT FULL SIZE TAPPING CUTTER. ALL VALVES ARE RATED AT 250 PSI FOR AWWA SERVICE AND 200 PSI FOR ULFM SERVICE. ALL VALVES ARE HYDROSTATICALLY TESTED TO 500 PSI. 10 YEAR LIMITED WARRANTY (Revised O327-2O11) 8571 8561 8057 8572 MECHANICAL JOINT ENDS FLANGED ENDS THREADED ENDS FLANGED X MJ 12° 2° • 12° 2" • 3° Y'•12° 8597 8576 8901 8701 PUSH-ON FOR PVC MECHANICAL TYTON ENDS FLANGED ENDS 2" 8" CUTTING-IN JOINT PUSH-ON FOR (DL & C900) POST INDICATOR VALVE (PIV) 4" • 12° 4' • 12" 3° • 12' F T 0 1E WEN) h 1 8902 8950 8071 8068 FLANGED & TYTON JOINT TAPPING X MJ MECHANICAL JOINT FLANGED ENDS PUSH-ON FOR (DI. & C900) TAPPING VALVE POST INDICATOR VALVE (PIV) OS&Y CONSTRUCTION 4" • 12" 4" • 12" 3' • 12" 21/2" • 12" A B C 0 E G H P Q IR S U V No of Turns In 'Full Open 7 3 1/4 - 51/4 10 7/8 - - 3 - - 71/4 - - 43/4 2 1/2° 7 1/2 - - 7 11 3/8 - - 3 1/4 163/8 13 7/8 71/4 - - 51/2 3 8 3 1/2 - 7 1/8 123/8 - 5 3/4 3 1/2 18 7/8 15 5/8 10 - - 10 4 9 41/2 63/4 - 14314 4 1/2 6 3/4 41/2 223/4 18 1/4 10 63/4 93/4 13 1/2 6° 101/2 5 77/8 - 19 51/4 7 3/4 5 30 1/8 23 3/4 12 75/8 11 3/16 191/2 8° 111/2 51/2 81/2 - 221/2 55/8 8 1/2 51/2 373/4 29 1/4 14 81/2 113/4 251/2 10° 13 7 10 - 261/2 7 10 - 453/4 35 3/8 18 10 131/2 311/2 12' 14 63/4 111/4 - 30 1 81/2 1 107/8 1 - 531/8 1 405/8 1 18 1 11 1 143/4 1373/4 KENNEDY VALVE A DIVISION OF MC WANE, INC. www.kennedwalve.com 2007 1021 E. Wafer Sfreet Elmira, New York 14901 P.O. Box 981 Phone (607) 734-2211 Fax 1-607-734-3288 (Revised 03-27-2011) MJ Accessories ANSI/AWWA C111/A21.11 H 00 _ :f q I I p I 28 for sizes 3-24 in. F 20 for sizes 30-60 in. MECHANICAL-JOINT GASKET1 NOM PIPE B C OD SIZE 0.13. A *1% E F G 2 2.50 0.48 0.62 0.31 2.48 0.12 0.15 1.05 3 3.96 0.48 0.62 0.31 3.86 0.12 0.15 1.05 4 4.80 0.62 0.75 0.31 4.68 0.16 0.22 1.22 6 690 062 075 031 673 016 022 122 8 9.05 0.62 0.75 0.31 8.85 0.16 0.22 1.22 10 11.10 0.62 0.75 0.31 10.87 016 0.22 1.22 12 13.20 0.62 0.75 0.31 12.95 0.16 0.22 1.22 14 15.30 0.62 0.75 0.31 14.99 0.16 0,22 1.22 16 17.40 0.62 0.75 0.31 17.07 0.16 0.22 1.22 18 19.50 0.62 0.75 0.31 19.13 .0.16 0.22 1.22 20 21.60 0.62 0.75 0.31 21.20 0.16 0.22 1.22 24 25.80 0.62 0.75 0.31 25.34 0.16 0.22 1.22 30 32.00 0.73 1.00 0.38 31.47 0.16 0.37 1.54 36 38.30 0.73 1.00 0.38 37.67 0.16 0.37 1.54 42 44.50 0.73 1.00 0.38 43.78 0.16 0.37 1.54 48 50.80 0.73 1.00 038 49.98 0.16 0.37 1.54 Cf kF TRANSITION MECHANICAL-JOINT uGASKET NOM PIPE I A B C(REF) OD 8 F G 2 2.375 0.56 0.66 0.31 232 0.12 0.21 1.10 3 3.500 0.72 0.64 034 3.43 0.12 038 1.10 4 4.500 0.76 0.73 - 0.33 4.43 0.20 0.37 1.26 6 6625 075 073 032 653 020 036 125 8 8.625 0.82 0.73 0.34 8.50 0.20 0.43 1.27 10 1O70 079 075 031 1059 020 039 126 / 12 12.750 0.84 0.75 0.33 12.56 0.20 0.44 1.28 UCAT.I4.OI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS FM HOUSTONCORPOMATE TOLL FREE 1-SOO-999-3E9 FAXZSI.SSS.MAO pippdMA.m Page 17 MJ Accessories ANSI/AWWA C111/A21.11 1-Bolts, Double Ended Rods & Nuts HSLA STEEL SPECIFICATIONS: Bolts & Nuts are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1 Material is High Strength Low Alloy Steel per ANSI/AWWA C1 11 /A21 .11. Threads per ASME B].] unified standard coarse (Class 2A & 213) MECHANICAL PROPERTIES CHEMICAL PROPERTIES Carbon 0.20% Max Manganese 1.25% Max Sulfur 0.05% Max Nickel 0.25% Mm Copper 0.20% Mm Combined 1.25% Mm (Ni, Cu, Cr) BLUE BOLT/NUT/ROD T-Bolts, Rods & Nuts have fluoropolymer coating material which is VOC-compliant, resin-bonded, thermally cured and dry lubricant, COATING PHYSICAL PROPERTIES Film Thickness: 0.3 to 0.4 mil per coat Number of Coats: 3 to 4 coats Adhesion: 1 mm cross hatch test + 5 Pulls. Good knife resistance Cure Test: 50+Rubs with MEK. No substrate exposure Pencil Hardness: Pencil Hardness: 4-6H Volatile Organic Compounds 2.74lbs/gal Yield Strength 45000 PSI (mm) Elongation in 2in. 20% (mm) Stainless Steel 1-Bolts & Nuts ALLOYS SS 304 & SS 316 PER ASTM F593 SPECIFICATIONS: 1-bolt dimensions are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. 1-bolt alloys SS 304 and SS 316 per ASTM F593 Heavy Hex Nut Alloys SS 304 & SS 316 per ASTM F594. MECHANICAL PROPERTIES Tensile Strength: 85,000 PSI to 140,000 PSI Yield Strength: 45,000 PSI (mm) COATING SPECIFICATION Nuts have fluoropolymer coating material which is VOC-Compliant, resin-bonded, thermally cured and dry lubricant. Film Thickness: 0.3 to 0.4 mil per coat • Pencil Hardness: 4-6H Number of Coats: 3 to 4 coats • Volatile Organic Compounds 2.74 lbs/gal Adhesion: 1 m cross hatch test + 5 Tape Pulls. • Continous use temperature - 356°F Cure Test: 50+ Rubs with MEK, no substrate exposure • Color: SS 304 is green. SS 316 is red A. AWWA MEMBER REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STARE PIPE PRODUCTS HOUSTON CORPORATEITOLL FREE I.NO-999.MA9 F4X 281.SSS.9000 Page 18 MECHANICAL JOINTIIBOLT PIPE SIZE (IN) ITORQUE 1 BOLT SIZE RANGE' OF (IN) TORQUE (FT-LBS) 2-3 5/8 45-60 4-24 3/4 75-90 30-36 1 100-120 42-48 11/4 120-150 'These torque ranges are requirements ofAWWA C600 Accessories ANSI/AWWA C111/A21.11 C B12 Minimum 1/16-inx45Chamfer. D T-HEAD (LOW NOM. SIZE ALLOY A IEEL) BOLT B itei C D THREADS PER IN. F H R %x3 ½x3½ 3/4X3½ 3/4 4 3/4x4¼ 1.50 150 1.75 175 1.75 0.625 0625 0.750 0.750 3.00 350 3.50 400 2.00 27 0 2.50 300 11 11 10 10 10 0.625 0625 0.750 0.750 1.062 06 02 1.250 1.250 0.625 0625 0.750 0.750 0.312 0.312 0.375 0375 0.375 0.750 4.50 3.00 0.750 1.250 0.750 1/4xS 1.75 0.750 5.00 3.00 10 0.750 1.250 0.750 0.375 3/4X5 ¼ - 1.75 0.750 5.50 3.70 10 0.750 1.250 0.750 0.375 1x5¼ 2.25 1.000 5.50 3.00 8 1.000 1.625 1.000 0.500 1x6 2.25 1.000 6.00 3.00 8 1.000 1.625 1.000 0.500 11/4 x 6 1 '/4X6 1/z 2.50 2.50 1.250 1.250 6.00 6.50 3.00 3.50 - 7 - 7 1.250 2.000 1.250 0.625 1.250 2.000 1.250 0.625 1'/4x8¼ 2.50 1.250 8.50 '_3,56_'_-_7 1.250 2.000 1.250 0.625 II - --T7TTT7I I1I'!17TI.-I1i - L ANTI-ROTATION T-HEAD (LOW ALLOYaSTEEL) p:isili isi NOM A SIZE B C D E THREADS PER IN. F H J R ¼x3 1.50 0.625 3.00 2.00 0.63 11 0.625 1.062 0.625 0.312 ~x3¼ 150 0.625 350 2.50 063 11 0.625 1.062 0.625 0.312 1/4 x3½ 1.75 0.750 3.50 2.50 0.63 10 0.750 1.250 0.750 0.375 34x4 1.75 0.750 4.00 3.00 0.63 10 0.750 1.250 0.750 0.375 3 x4½ 1.75 0.750 4.50 3.00 0.63 10 0.750 1.250 0.750 0.375 ~z5 1.75 0.750 5.00 3.00 0.63 10 0.750 1.250 0.750 0.375 UCATI4.OI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS HOUSTON CORPORATE TOLL FREE I-leo-999-3I9 FAXRSI-SS8-9000 L) Page 19 LI MI x MI BENDS 90, Mj x Mj 45, Mj x Mj 22 '/2- Mj x Mj 11 '/4o Mj X Mj NOM. T A R w'r A R 'v'r A R Vt" A R WT SIZE (LBS.) (LBS.) (LBS.) (LBS.) 2 0.39 3.25 2.25 14 1.80 1.96 13 1.80 4.02 13 1.80 8.12 13 3 0.48 5.50 4.00 35 3.00 3.62 30 3.00 7.56 30 3.00 15.25 30 4 0.52 6.50 4.50 55 4.00 4.81 50 4.00 10.06 50 4.00 20.31 so 6 8.00 6.00 85 5.00 7.25 75 5.00 15.06 75 5.00 30.50 75 0.55 8 0.60 9.00 7.00 125 5.50 8.44 110 5.50 17.62 110 5.50 35.50 110 10 0.68 11.00 9.00 190 6.50 10.88 155 6.50 22.62 160 6.50 45.69 160 12 0.75 12.00 10.00 255 7.50 13.25 215 7.50 27.62 220 7.50 55.81 220 14 0.66 14.00 11.50 340 7.50 12.06 270 7.50 25,12 275 7.50 50.75 275 16 0.70 15.00 12.50 430 8.00 13.25 340 8.00 27.62 345 8.00 55.81 345 18 0.75 16.50 14.00 545 8.50 14.50 420 8.50 30.19 430 8.50 60.94 430 20 0.80 18.00 15.50 680 9.50 16.88 530 9.50 35.19 535 9.50 71.06 540 24 089 2200 1850 1025 1100 15.00 1812 27.75 755 1380 1100 15.00 3769 765 57.81 1400 1100 15.00 7612 116.75 770 1410 30 1.03 25.00 21.50 1690 36 115 2800 2450 2475 1800 3500 2095 1800 72.88 2135 1800 14725 2145 42 1.28 31.00 27.50 3410 21.00 42.25 2955 21.00 88.00 3020 21.00 177.69 3035 48 142 3400 3050 4595 2400 4950 4080 2400 10306 4170 2400 20812 4190 BENDS NOM. T SIZE A B R WT (LBS.) I B R WT (LBS.) A B R 'WT (LBS.) A B R WT (LBS.) 3 0.48 5.50 13.50 4.00 35 3.00 11.00 3.62 30 3.00 11.00 7.56 30 3.00 11.00 15.25 30 0.52 6.50 14.50 4.50 50 4.00 12.00 4.81 45 4.00 12.00 10.06 45 4.00 12.00 20.31 45 6 0.55 8.00 16.00 6.00 80 5.00 13.00 725 70 5.00 13.00 15.06 70 5.00 13.00 30.50 70 8 0.60 ' 0.68 9.00 17.00 7.00 120 3.50 13.50 8.44 105 5.50 13.50 17.62 105 5.50 13.50 35.50 105 10 11.00 19.00 9.00 190 6.50 14.50 10.88 155 6.50 14.50 22.62 160 6.50 14.50 45.69 160 12 075 1200 2.000 1000 255 750 1550 1325 215 750 1550 2762 220 750 1550 5581 220 14 0.66 14.00 22.00 11.50 325 7.50 15.50 12.06 255 7.50 15.50 25.12 260 7.50 15.50 50.75 260 16 0.70 15.00 23.00 12.50 410 8.00 16.00 13.25 320 8.00 16.00 27.62 325 8.00 16.00 55.81 325 24 0.89 22.00 30.00 18.50 985 11.00 19.00 18.12 715 11.00 19.00 37.69 725 11.00 19.00 76.12 730 30 1.03 25.00 33.00 21.50 1585 15.00 23.00 27.75 1275 15.00 23.00 57.81 1295 15.00 23.00 116.75 1305 36 1.15 28.00 36.00 24.50 2310 18.00 26.00 35.00 19 i__ 30 18.00 26.00 72.88 1970 18.00 26.00 147.25 1980 42 1.28 I ll 31.00 39.00 27.50 3200 21.00 29.00 42.25 2745 21.00 29.00 88.00 2810 21.00 29.00 177.69 2825 UCAT.I4.OI -REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR' PIPE PRODUCTS HOUSTON CORPORATE ITOLL FREE IIOO999.3R)9 F4X28I.558.9REO FMçva Page 22 GUARDIAN I MIAMI, FL VqL8Ph.FIREEQLRPMENT,IN C. DETAIL AND SUBMITTAL SHEET EET 00.327.6584• Fax 800.827.3869 6300 Seri es Fire De pt. Inlet .11 . r.i i Bodies Project/Location: Date: Architect/Engineer: Qty: Contractor: [Appropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow (minimum), per 21/2" inlet. Two and three-way - inlet connections feature clappered brass bodies (straight or angle pattern), with female hose thread swivel inlets and female outlets. Cast brass construction, standard. Model N— 6314* Outlet Back Two and IThree-Way Size 4" x 2/" x 21/2" Co ,1,II,I[.1IT. 1 51/2 F B 81/8 0 6315* Angle 4" x 21/2" x 21/2' 1 81/a 8I4" E] 6324 Back 4" x 21/2" x 21/2" 2 71/4"10V2" 0 6325 Angle 4" x 21/2" x 21/2" 2 81/4" 10h/2" E] 6326 Back 6" x 21/2" x 21/2" 2 71/4 101/2" 0 6327 Angle 6" x 21/2' x 21/2" 2 1 10" 10V2" 0 6336 Back 6" x 21/2" x 21/2" x 21/2" 3 101I2" 0 6337 Angle 6" x 21/2" x 21/2" x 21/2" 3 111/2" 141/2" Body Lettering IJ AUTO SPKR DSTANDPIPE t:i Blank (unlettered) *Auto Spkr lettering only Optional Finish:[] -B Polished Brass Threads: 0-C Rough Chrome Plated 0 NST 0 -D Polished Chrome Plated 0 Other Plugs with Chains and Break Caps - Used to keep fire dept. inlet connections free of debris and protect female threads. Contact factory for current listings and approvals Plugs with Chains Model No. I Size Type I[J 6404 1 21/2" I Brass Optional Finish: 0-B Polished 0-C Rough Chrome Plated 0 -D Polished Chrome Plated Break Caps Model No. I size I Type . 06406 I21/2" 111Aluminum 0 6407 21/" I Plastic Threads: Adjustable Plugs ONST Model No. I Size I Type 0 Other 0 6408 21/2" 1 Aluminum 0 6409 1 21h" I Plastic 6337