Loading...
HomeMy WebLinkAbout2855 GAZELLE CT; ; FPC2020-0207; PermitPERET REPORT Cr'city of Carlsbad F.iiIr1&eTr1mjt Print Date: 02/01/2021 Permit No: FPC2020-0207 Job Address: 2855 GAZELLE CT, CARLSBAD, CA 92010-6670 Status: Closed - Fina led Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091202000 Track #: Applied: 12/08/2020 Valuation: $162,319.90 Lot #: Issued: 12/16/2020 Occupancy Group: Project #: Finaled Close Out: 02/01/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: ION IS -SPRINKLER TI (32 HEADS) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTEMS INC DARIEN MORAN 249 E EMERSON AVE 13142 NELSON ORANGE, CA 92865-3304 CARLSBAD, CA (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Ffu-D -o -O2o1- MATERIAL DATA SUBMITTAL lonis Pharmaceuticals Tenant Improvement 2855 Gazelle Court Carlsbad, CA 92010 Pacific Fire Systems, Inc. 12316 Oak Knoll Rd. Suite A Poway, CA 92064 (858) 883-2333 Phone • (858) 883-2334 Fax April 8, 2011 Sprinkler 54a MIRAGE® STANDARD AND QR CONCEALED PENDENT N 1 1(1 N G47 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-pro- file cover assembly that provides up to 1/2" (12.7 mm) of vertical adjustment. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The 'push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Ref. No. 096e112 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to Approval Chart 1 and Design Criteria on page 54c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 54d for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C 19500 for Sprinkler VK462 Viking Technical Data may be found on Phosphor Bronze UNS-051000 for Sprinkler VK463 The Viking Corporation's Web site at Deflector Pins: Stainless Steel Alloy http://www.vikinggroupinc.com. Bulb: Glass, nominal 3 mm diameter The Web site may include a more recent Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel edition of this Technical Data Page. UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F 103005 Replaces page 54a-f, dated February 25, 2011. (Revised LPCB Approval. - Removed UL listing from 165 OF Cover 15394. Obsoleted sprinkler 14697.) Sprinkler 54b April 8, 2011 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage' Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = B, 175°I79° = D, 200°/93° = E For example, sprinkler VK463 with a 155°F/68°C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix (°F/°C): 1350/570 UL (1390/590 FM and LPCB) = A, 165°/740 = C For example, cover 13504 with a Polished Chrome finish and a 165°F/74°C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135°F (57°C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) —Requires a 1/2" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. April 8, 2011 Sprinkler 54c MIRAGE® STANDARD AND QR CONCEALED PENDENT sJ W*j SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Classification Temperature Rating' Ceiling Temperature' Assembly (Required) Bulb Color Ordinary 155°F (68°C) 100°F (38°C) Red 139'F (59°C) FM and LPCB Intermediate 175°F (79°C) 150°F (65°C) 165°F (74°C) Yellow Intermediate 200°F (93°C) 150°F (65°C) 165°F (74°C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. CUSTO zcl 0 Identification of Custom Paint Color: All custom color pointed cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint dot) of the paint on the label, Figure 1: Identification of Custom Paint Color for Concealed Covers DO NOT PAINT 3-5/16" (84,1 mm) Figure 2: Square Cover Assembly 15394 Sprinkler 54d April 8, 2011 MIRAGE® STANDARD AND QR CONCEALED PENDENT NIKJWG4j SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com SprnkIer Temperature Rating Approval Chart I (UL) j— coverPlateTemperatureRating Miragetm Concealed Pendent Sprinklers VK462 and VK463 fAWI4- Cover Plate Finish KEY I NPT Thread I Nominal I Maximum I Listings and Approvals4 Sprinkler I SIN I I Size I I K-Factor I Water Working I (Refer also to Design Criteria below.) I Inch mm I U.S. I metric' I cULus' I NYC I VdS I LPCB I CE Base Part No.1 Pressure Standard Response Applications 13503A VK462 1/2" 15 5.6 80.6 1 175 psi (12 bar) I -- -- AYI,CZ1 AY1,BZ1 AY1,CZ17 Quick Response Applications 13503A I VK462 I 1/2" 15 I 5.6 I 80.6 J 175 psi (12 bar) AV1, BX1 AV1, BW16-- 13667A I VK463 I 1/2" 15 5.6 80.6 I 250 psi (17.2 bar)' AV1, BX1 I AV1, BW16 -- -- - Cover Plate Assembly Temperature Ratings8 Cover Plate Assembly Finishes9 Sprinkler Temperature Ratings V - 135°F (57°C) cULus Listed cover 135041, 136421 (large diameter), 1 - Polished Chrome, Brushed Chrome, or 153941 (square cover plate) A- 155°F (68°C) W- 165°F (74°C) cover 135041 or 136421 (large diameter) Bright Brass, Antique Brass, B - 175°F (79°C) and 200°F (93°C) X - 165°F (74°C) cover 135041, or 136421 (large diameter) Brushed Brass, Brushed Copper, C - 200°F (93°C) Y - 135°F (57°C) cover 135041 LPCB Approved as 139°F (59°C) Painted White, Painted Ivory, or Z - 165°F (74°C) cover 135041 Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. ((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 The 135/139°F cover has an orange label. The 165°F cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. April 8, 2011 Sprinkler 54e MIRAGE® STANDARD AND QR CONCEALED PENDENT NIKJNG4 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) SprInMerTemperature Rating Mirage Standard Response Concealed Pendent Sprinkler VK462 L Awl* Cover Plate Finish KEY -- Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric2 Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1 Cover Plate Assembly Temperature Ratings4 Cover Plate Assembly Finishes' Sprinkler Temperature Ratings w - 139°F (59°C) cover 135041, 136421 (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F (68°C) or 153941 (square cover plate) Brass, Antique Brass, Brushed Brass, B - 175°F (79°C) and 200°F (93°C) X - 165°F (74°C) cover 135041, 136421 (large diameter), Brushed Copper, Painted White, Painted or 153941 (square cover plate) Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. The 139°F cover has an orange label. The 165°F cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. NEVER install the sprinkler by applying the installation wrench across the frame arms, DU NOT over-tighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. Sprinkler Wrench Flat rinkler cx me Arms 2-1/4' (57,2 mm) diameter opening is required in the ceRing, bly ap Dr .ise )IE) Sprinkler Wrench (Port No. 4047 is shown) Sprinkler 54f April 8, 2011 MIRAGE® STANDARD AND QR CONCEALED PENDENT "J II(1I1Gj SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com A 1/2' ratchet s required (not ilalole from Viking), Step 1: Carefully slide the wrench sideways around the deflector and pins. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. DO NOT apply more than 25 ft. tbs. of torque. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Correct Use of Wrenches NPT (15 mm) L 29/16 2 -1/16 3 /16; (65 mm) (52 mm) - Maximum Minimum _77777714:. r-LIL 2-3/4" (70 mm) or 3-5/16' (84.1 mm)] Note: Upon sprinkler activation, the deflector descends to approximately 13/16" (20,6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 Replaces page 54a-f, dated February 25, 2011. (Revised LPCB Approval. Removed UL listing from 165 °F Cover 15394. Obsoleted sprinkler 14697.) YOULL MOOSE' 'TUBE APPROVALS AND SPECIFICATIONS ASTM A135, Grade A ASTM A795, Type E, Grade A Pressure rated to 300 psi Underwriters Laboratories- United States of America Underwriters Laboratories-Canada Factory Mutual NFPA-13 NFPA-13R NFPA-14 CIVIL DEFENSE APPROVAL- United Arab Emirates Made in the United States of America UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, preaction and deluge sprinkler systems. LEED v4 Certified SCHEDULE 10 & 10 SPRINKLER PIPE SUBMITTAL DATA SHEET FINISHES AND COATINGS Schedule 10 & 40 Sprinkler Pipe receives an 00 mill coating of water-based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. Schedule 10 & 40 Sprinkler Pipe (black) receives an ID mill coating of Eddy Guard II MIC preventative coating. EG2 has been tested at independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. Schedule 10 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION Every length of Bull Moose fire sprinkler pipe features large, easy-to- read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. 0 ipy ow 91 1.0. (In) 1.097 1.442 1.682 2.157 2.635 3.260 4260 6.357 8249 Empty WeIght (Ib/ft) LWater 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Filled Weight (lb/ft) 1.800 2.518 3.053 4.223 5.893 7.951 11.796 23.038 40.086 C.R.L* 1527 9.91 7.76 6.27 4,92 3.54 2.50 1.158 1.805 Pieces per Lilt - - - 0.0. (in) 91 1 61 61 37 30 1 19 1 19 10 1 1.315 1.660 1.900 - - 0.0. (In) 1.315 1.660 1.900 2375 2.815 3.500 4.500 6.625 8.625 2.375 2.875 3.500 4.500 - I.D. (IN) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Empty Welght(lb/ft) 1.680 2.270 2.720 3.660 5.800 1.580 10.800 Water Filled Weight (Ib/ft) 2.055 2.978 3.602 5.114 7.875 10.783 16.316 t.R.R.* 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY SUBMITTAL INFORMATION (~D C(& <.8> Project ContractorL Engineer Specification I Reference System Type Date r Locations [ Comments ED Schedule 10- Black C) Schedule 10- Hot Dip Galvanized C) Schedule 40-Black () Schedule 40- Hot Dip Galvanized BULL]V[DDSETU B E.GDM 1I1I) '3, iAX Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring C®US USTED MPOtb Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2' thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4' thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm orlomm 31/ 25/8 400 11 3/4 3/8 8mm 0r10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 37/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13A6 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1A6 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 314" and 11/4" Throat Openings Component of State of California OSHPD Approved c 1k us LISTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8, 1/2 and 5/8 rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4 (Fig. 65) or 11/4 (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8 rod will support 1/2' thru 4 pipe, 1/2 rod will support 1/2 thru 8 pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH 951.737.5599 • FAX 951.737.0330 ii CUSTOMER SERVICE • 800.786.5266 wwwfolco.com Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8 thru 7/8 rod by 4 thru 16 length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1 Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 1/2 9/16 Specify Specify 2 5/8 11/16 3/4 13/16 Specify Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. Component of State of California OSHPD Approved I: @L LISTED Seismic Restraints System OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 • A www.tolco.com 0- DESCRIPTION SAMMYSO MODEL # HANG ROD SIZE 01? MSTR Hangennate+ For Concrete - Internally Threaded PFM221 1100 1/4" x 1-5/8" CST 200 Vertical 1/4' 25 125 1/4" x 1-5/8" CST 20 Vertical 3/8' 25 125 PFM221 1250 1/4x2-1/2" CCST516 Vertical 3/8' 25 125 - Hangermate+ For Concrete - Externally Threaded lDhiJI 1/4" x 1-5/8" - Vertical 3/8" 25 125 1!JEI1IIII 1/4" x 2.1/2" - Vertical 3/8" 25 125 Hangermate+ Pivot For Concrete - Angled Applications lM5III 1/4 x 2" SH-GST/CST 20 Variable 3/8" 25 125 Hangermate+ Suspender For Concrete - Dual-Directional - VNJrlhts1II 5/16" x 2-1/4 ' - Vert. & KarL 3/8" 25 125 The Complete Anchoring Solution - histallaUon Accessories and Tools DESCRIPTION HANGERMATE+ OTY MSTR 01? 1/4" Socket Driver Concrete Rod Hanger 1 5 I1OOflP1øI 3/8" Socket Driver Concrete Rod Hanger 1 5 1/2" Drive Socket Externally Threaded ccrete Rod Hanger 1 - - 5'2*IKIl1!I Suspender Driver Suspender 1 5 rP3dPJ!II Pivot Driver Pivot 1 5 1/2 impact Ratedw External 1 - Deep Socket bk'P1IAlI 1/4" Hex to 1/2" Square Adapter hIM 1/4" X 6" (4" usable length) SDS+ Full Head Carbide Masonry Dull Bit IYV.MOhJ Hex Shank SDS-Plus (only for Pivot for Concrete) 1mi1I Adapter for hanging 1/2" rod (3/8" to 1/2' Adapter) 20V MAX* Brushless Rotary Hammer IIi!W1PJ 20V MAX* XR Brushless 3-Speed Impact Driver I' 20V MAX* Lithium Ion 3/8" Impact Wrench Cordless Threaded Rod Cutter * Maximum initial battery voltage (measured without a workload) Is 20 volts. Nominal voltage Is 18. \JSTM Product Specifications I Hole-Cut System MODEL V-723 SADDLE-LET (Small Mechanical Tee) Ffi~~ The Model 723 Saddle-Let is the ideal outlet fitting for direct connections to sprinkler heads, drop nipples and or gauges. No need for welding, lust cut or drill a hole at the desired outlet location. Position the Saddle-Let so that the locating collar fits within the hole and secure with the U-bolt and nuts. The Saddle-Let comes with a standard black finish or as an option can be supplied electro zinc plated or painted orange. The Saddle- Let allows full bore flow and is pressure rated to 300 psi (20 bar). c®uS <::@> LISTED APPROVED Hole Dia. Dimensions-mm'n Take-Out Nominal Size +1.6,-0/+0.063,-0 T Bolt Size Bolt Torque Weight mm/in mm/in A B C mm/in in N-M/Lb-Ft Kgs/Lbs 32 x 15 30 53.0 89.0 56.0 35.0 3/8e 20-30 0,4 1.25 x 0.5 1.18 2.08 3.50 2.20 1.38 U-Bolt 15 -22 0.9 32 x 20 30 53.0 89.0 56.0 35.0 3/8e 20-30 0.4 1.25 x 0.75 1.18 2.08 3.50 2.20 1.38 U-Bolt 15 -22 0.9 32 x 25 30 56.0 89.0 56.0 38.0 3/8o 20-30 0.4 1.25 x 1 1.18 2.20 3.50 2.20 1.50 U-Bolt 15-22 0.9 40 x 15 30 55.0 89.0 56.0 35.0 3/80 20 -30 0.4 1.5 x 0.5 1.18 2.16 3.50 2.20 1.38 U-Bolt 15-22 0.9 40 x 20 30 55.0 89.0 56.0 35.0 3/8e 20 -30 0.4 1.5 x 0.75 1.18 2.16 3.50 2.20 1.38 U-Bolt 15-22 0.9 40 x 25 30 58.0 89.0 56.0 38.0 3/8e 20 -30 0.4 IS x 1 1.18 2.28 1 3.50 2.20 1.50 U-Bolt 15-22 0.9 sox 15 30 64.0 98.0 56.0 42.0 3/8o 20 -30 0.4 2 x 0.5 1.18 2.51 3.85 2.20 1.65 U-Bolt 15-22 0.9 50 x 20 30 64.0 98.0 56.0 42.0 3/8e 20 -30 0.4 2 x 0.75 1.18 2.51 3.85 2.20 165 U-Bolt 15-22 0.9 SO x 25 30 67.0 98.0 56.0 45.0 3/8o 20 -30 0.4 2 x 1 1.18 2.63 3.85 2.20 1.77 U-Bolt 15-22 0.9 65 x 15 30 69.0 111.0 56.0 51.0 3/8e 20 -30 0.4 2.5 X 0.5 1.18 2.71 4.37 2.20 2.00 U-Bolt 15-22 0.9 65 x 20 30 69.0 111.0 56.0 51.0 3/80 20-30 0.4 2.5 x 0.75 1.18 2.71 4.37 2.20 2.00 U-Bolt IS-22 0.9 65 x 25 30 72.0 111.0 56.0 54.0 3/8e 20 -30 0.5 2.5 x 1 1.18 2.83 4.37 2.20 2.13 U-Bolt 15-22 1.1 Hole diameters listed are suggested hole saw diameters. 1: Take-out (Center of run to end of pipe to be engaged) Trusted above all TM 25 N ~ YJ W63",