HomeMy WebLinkAbout2855 GAZELLE CT; ; FPC2020-0212; Permitk-city of PERMIT REPORT Carlsbad Print Date: 02/03/2021 Permit No: FPC2020-0212 Job Address: 2855 GAZELLE CT, CARLSBAD, CA 92010-6670 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2091202000 Track #: Applied: 12/22/2020 Valuation: $162,319.90 Lot #: Issued: Occupancy Group: Project #: Finaled Close Out: 02/03/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: IONIS - INSTALLATION OF 3 NEW NOTIFICATION DEVICES Applicant: ELECTRONIC CONTROLS SYSTEM LLC RICHARD SAYLORS 12575 KIRKHAM CT POWAY, CA 92064-8844 (858) 813-1911 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE TI Fire Alarm System $620.00 Total Fees: $813.00 Total Payments To Date: $813.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov P1'CZDO - JA _ Albireo Energy Partnering for Success Seminar Room Conversation TI lonis Pharmaceuticals 2855 Gazelle Court Carlsbad, CA 92010 Product Data Submittal Fire Alarm Tenant Improvement December 21, 2020 Albireo Energy. 12575 Kirkham Ct • Poway, CA 92064 Phone: 858-513-1911 • www.albireoenergy.com N 'N S S _ Albireo Energy Partnering for Success Table of Contents 1. Fire Alarm Equipment BPS6A Existing Notification Power Supply (Provided for Reference Only) GCF-HDVM Ceiling Horn Strobe fl S Albireo Energy• 12575 Kirkham Ct • Poway, CA 92064 • Phone: 858-513-1911 • www.albireoenergy.com \ 'N AEA 76-91-E Vol.13 * 7300-1657: 0229 W-FUh'Iie I> Power Supplies and Accessories n Remote Booster Power Supplies BPS6A, BPS1OA Overview The Booster Power Supply (BPS) is a UL 864, 9th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NAGs) or auxiliary power for Mass Notification/ Emergency Communication (MNEC), as well as life safety, security, and access control applications. The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS's unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition (UO)X)Fire Alarm Systems UL636 (ANET, UEHX7) Holdup Alarm Units and Systems UL609 )AOD(, AOD<7) Local Burglar Alarm Units and Systems UL294 (ALVY. UEHX7) Access control Systems UL365(APAW APAW7) Police Station Connected Burglar Alarm Units and Systems UL1 076 (APOU, APOU7) Proprietary Burglar Alarm System Units UL1610 (AMC)q Central Station Alarm Unit ULC-S527 (UOXXC) Control Units, Fire Alarm (Canada) 0L33AoD7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) Page 1 of 4 Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 DATA SHEET E85005-0125 Not to be used for nstaletion purposes Issue 1 S ON (I) CL CD CD 02 03 D4 05 06 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in (43.2 cm) (8.9 cm) (33.0 crr) (16.5 cm) (8.6 cm) (30.4 cm) Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Dimensions D0 00 , 5 1 Top View Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be act - vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. BPS NACs can be configured for a 3-3-3 temporal or continuojs output. California temporal rate outputs are also available on cer- tain models. This makes the BPS ideal for applications requiring signaling rates that are not available from the main system. In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- Route AC supply ments of the main system. The BPS shall be capable of supervis- through these ing and charging batteries having the capacity of 24 ampere-hcurs knockouts only for Mass Notification/Emergency Communication (MNEO), life (Nonpower-limited safety and security applications, and the capacity of 65 ampere- and supervised) hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall not impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 Power-limited wiring area C Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxil arty power. Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. S DATA SHEET E85005-0125 Not to be used for installation purposes Issue 1 Configuring the Booster for AC Power Fail delay operation* INotification aooliance circuit UL listed EOL 15 kO Notification appliance circuit (NAC) UL listed EOL 15 kO EOL 47 kO CC1(S) module [l][3] 0 0 - Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAC end-of-line resistors are not required to be installed at the booster's terminals. This allows multiple boosters to be driven from a single NAG circuit without the need for special configurations. NAC Circuit I ___ To next signaling NAC Circuit j device, booster, or EOL resistor °' ° l CD ) NAC output #1 Fire Alarm ,, , ) NAC output #2 Control Panel i > NAC output #3 ) NAC output #4 0 C C Booster Power SuDDIV Multiple CC1(S) modules using the BPS's sense inputs T1310 Notification appliance circuit (NAG) NAG1/ + UL listed AUX1 -j_ — EOL 15 KW NAC2/ + AUX2 Notification appliance circuit (NAC) NAG3/ +L UL listedJ— AUX3 -3— 3z IF EOL 15 KW NAG4/ +] AUX4 - 200 mAAUX , - Continuous CO IN Sense 1 COM OUT -EOL 47K II IN Sense 2 COM fjJ - It oUTE1J EOL47K II II NO EIl -11+ -11+ Trouble COM 5I 5I If NC 109 109 TB2 CC1(S) module CG1(S) module 0 00 00 Data in from previous device or Signature controller Security and access • • Data in from \J I L4_,. Data out to moul[4] or Signature CT1 previous device 5__J l. next device controller *The Booster supports AC Power fail delay Data out to of three hours via its trouble contact when next device dip switch SW2-6 is on. All other troubles are reported to supervising module or panel without delay via Sense inputs. [3] BPS TB1 24V 12V / + i&:l 240C12 6 Security - device / + fNAC3/ - + - = Security — EOL monitoring device - device Control panel S [1] Disable the BPS's ground fault jumper (JP3) Page 3 of 4 Card reader Card reader controller controller BPS [1] Card reader controller +— +— A A A To next device or end DATA SHEET E85005-0125 Not to be used for 'nsta"at or purposes Issue 1 Fe ;FE' t',. [EF. M-N.EMEI Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Model 6.5 amp Booster 10 amp Booster AC Line Voltage 120VAC or 220-240VAC 50/60Hz 120VAC or 220-240VAC 50/60Hz 390 watts 580 watts Notification Appliance Circuit Ratings 3.OA max. per circuit @ 24Vdc nominal 6.5A max total all NACs 3.OA max. per circuit @ 24Vdc nominal 1 O max total all NACs Trouble Relay 2 Amps @ 30Vdc Auxiliary Outputs Four configurable outputs replace NACs 1 2, 3 or 4. as auxiliary outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current (from an existing NAC) 3mA © 12Vdc, 6mA © 24Vdc Booster Internal Supervisory Current 70mA + 35 mA for each circuit set to AUX Booster Internal Alarm Current 270mA Signature Mounting Space Accomodates three two-gang modules. Maximum Battery Size 10 Amp Hours (2 of 12V1 OA) in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing @32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper S Agency Listings UL, ULC, CSFM Model BPSCAA provides selection for California rate, in place of temporal. Maximum of 8 Amps can be .jsed for auxiliary output. Ordering Information Catalog Number Description Shipping Wt. lb (kg) BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS6AC 6.5 Amp Booster Power Supply (ULC) 13(5.9) BPS6A/230 6.5 Amp Booster Power Supply (220 13(5.9) BPS6CM 6.5 Amp Booster Power Supply with California rate 13(5.9) BPS10A 10 Amp Booster Power Supply 13(5.9) BPS10AC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS10N230 10 Amp Booster Power Supply (220\i) 13(5.9) BPS10CM 10 Amp Booster Power Supply with California rate 13(5.9) Requires installation of sepa- rate battery cabinet. Related Equipment BPS supports batteries greater - 12V6A5 7.2 Amp Hair Battery, two required 3.4 (1.6) than 24 Amp hours for access control applications Only. 12V1 OA 10 Amp Hour Battery, two required 9.5 (4.3) For earthquake anchorage, 3-TAMP Tamper switch including detailed mounting BC-1 EQ Seismic Kit for BC-1. Order BC-1 separately. See note 3. weights and center of gravity BPSEQ Seismic kit for BPS6A or BPS1 0 Booster Power Supplies. See detail, refer to Seismic Applica- note 3 tion Guide 3101676. Approval of panel anchorage to site BC-1 Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) structure may require local BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) AHJ, structural or civil engineer 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) review. 12V24A 24 Amp Hour Battery, two required (see note 1) 20 (9.07) 12V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40(18.14) 12V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) 5 Page 4 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 m0 nmm~w~fflsa t 19g,4 W~W Uihiies ( '•' Field Configurable Ceiling Horn -Strobes Genesis Series D Strobes, Horns, Bells, Chimes One or more patents pending. FC MEA CE 7300-1657: 0202 S218 L Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required 'cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Page 1 of 4 Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration DATA SHEET E85001-0559 Not to be used for installat,on purposes Issue 1 S Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for :he hearng impaired. Prevailing codes require strobes to be used where ambi ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where amb - ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for detals. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequa:e to alert or waken occupants in the protected area. Researc indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 Cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguarcs such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. Al models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambien: sound level, or 5 dB above the maximum sound level having a duraticn of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions 6.8' dia. "I (173 mm) .,.- t (25 mmi 0.60"(15 mm) Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. Polarity alarm EO next fiance, I-of-line etum to ontrol iipment Note: Strobes must have continuous voltage. S S Page 2 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting UL 15 c 30 c 75 c S Rating RMS RMS RMS 95 c RMS GC-HDVMH High Cd Temporal Horn-strobe: High dB Setting 95 c 115 c 150 Cd 177 c RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16Vfwr 189 253 417 451 487 578 670 711 GC-HDVMH High Cd Temporal Horn-strobe: High dB GC-HDVM Temporal Horn-strobe: High dB Setting Setting Typical 15 c 30 c 75 c 95 c 95 c 115 c 150 c 177 c Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24 Vdc 80 71 108 101 185 180 212 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 GC-HDVMH High Cd Temporal Horn-strobe: Low dB GC-HDVM Temporal Horn-strobe: Low dB Setting Setting Typical 15 c 30 c 75 c 95 c 95 c ll5cd 150 Cd 177 Cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 S 33Vfwr Notes and Comments 1 Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used 'mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output UL464 Average Peak High dB ------ Sttinn T,nnrI i qtandw Temporal! Temporal! - - - ieauy 3WdUy 16 Vdc j 79.8 83.2 90.6 93.6 24 Vdc I 83.3 85.4 93.6 96.6 33 Vdc 1 85 87.8 95.7 98.7 Low dB UL464 Average Peak - T Temporall ' Temporal! Steady 1 Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33Vdc 80.9 85.9 91.8 95.1 Notes 1. At values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 Light output - (effective cd) Percent of UL rating versus angle DATA SHEET E85001-0559 Not to be used for nstallat.ori purposes Issue 1 S Rk Specifications H ousing Textured LA/ stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear) Mounting North-American 4" square box 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-S526, year 2004 UL Agency listings/app-ovals requirements for standards UL1638 and UL1971, and complies with UL1 480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAG only) when used with optional Cl M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe fash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional G1 M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, then repeat cycle S FE FEr. . NE ElY MNAnEMEN° Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information Catalog Housing Ship Number Marking Color Description Wt. lbs (kg) GC-HDVM White None GCF-HDVM White "FIRE" Genesis Ceiling/Wall Horn-Strobe GCFR-HDVM Red "FIRE" with selectable 15, 30, 75, or 95 cd output 0.82 GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe (1.8) GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories Cl M-RM Genesis Signal Master - Remote Mount (1 -gang) 0.2 (0.1) SIGA-CC1 S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 (0.08) White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. S Page 4 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657-.0202 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models "EST G1-HV15, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, Gi R-HDV1575, Gi F-HDV1575, and Gi RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33Vdc/V1Wr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, Gi R-HDV1575, G1F-HDV1575, G1RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd S 15 -95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, Gi F-HDV1575, Gi RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GCHDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division