Loading...
HomeMy WebLinkAbout2855 GAZELLE CT; ; FPC2017-0043; Permit(ity of Carlsbad Print Date: 10/19/2021 Permit No: FPC2017-0043 Job Address: 2855 GAZELLE CT, CARLSBAD, CA 92010-6670 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Applied: 02/16/2017 Valuation: $0.00 Lot #: Issued: 04/18/2017 Occupancy Group: Project #: Finaled Close Out: 07/29/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: IONIS PHARMACEUTICALS - C WING VIVARIUM PHASE 1- SPRINKLER TI 7 - 100 HEADS (69) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A jITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 16-310 IONIS PHARMACEUTICALS 2855 Gazelle Court Carlsbad, CA 92010 ES-A-3000SS Series 3000SS EXISTING A M E S Din ihie Check Detector Assemblies FIRE Sizes: 21/2 - 12' (65 - 300mm) Series 3000SS Double Check Detector Assemblies are designed for use in accordance with water utility non-health hazard containment requirements. It is mandatory to prevent the reverseflov-iof fire protection system substances, i.e., glycerinwetting agents, stagnantwater and water of non-potable quality from being pumped or siphoned into the potable water supply. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when conneoted to a drinking water supply. Degree of hazard present is determined by the local authority having jurisdiction. The main valve body shall be manufactured from 300 Series stainless steel to provide corrosion resistance, 100% lead free* through the waterway. Tie double check detector assembly consists of two independently operat- ing, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double chock including shutoff valves and required test cocks. Each cam-check shall be internally loaded and provide a positive drip tight closure against reverse flow. Cam-check includes a stainless steel cam arm and spring, rubber faced disc and a replaceable. seat. There shall be no brass or bronze parts used within the cam-check valve assembly. The check valve seats shall be of molded thermoplastic construction. The use cf seat screws as a retention method is prohibited. All internal parts shall be accessible through a single cover on the valve assembly. The valve cover shall be held in place through the use of a single grooved style two-bolt coupling. The bypass line shall be hydraulically sized to accurately measure low flow. The bypass line shall con- sist of a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 300C-SS. Materials All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless steel, Check assembly: Noryl® Flange dimension in accordance with AW'INA Class D. Noryl® is a registered trademark of General Electric Company. V!'h1 1lI[I It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. Contractor Approval Contractor's P.O. No. Representative Features Cam-Check Assembly valve provides low head loss Short lay length is ideally suited for ret- rofit installations Stainless Steel body is half the weight of competitive designs reducing installa- tion and shipping cost Stainless steel construction provides long term corrosion protec:ior and maximum strength Single top access cover with two-bolt grooved style coupling for ease of main- tenance No special tools required for servicing Compact construction allows br smaller vaults and enclosures Furnished with 1/8" x 3/4" bronze meter (gpm or cfm) Detects underground leaks aid unauthorized water use Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG - less shutoff valves OSY - UL/FM outside stem ard yoke resil- ient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate conrection OSY GxG - grooved inlet gate conr:ection and grooved outlet gate connection CFM - cubic feet per minute GPM - gallons per minute motor Post indicator plate and operating nut available - consult factory *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name - Job Location Engineer - Approval - Ames product specifications in U.S. customar, units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modiN product design, construction specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com Pressure - Temperature Temperature Range: 33°F - 110°F (0.5°C - 43°C) Maximum Working Pressure: 175psi (12 bar) Capacity Flow curves astested byUnderwriters LaboratoryperUL1469, 1996. * Rated flow **UL Tested °• _____.I_.I____. _______. I__I u• ., .. :u (Pa psi 4" (1 00mm) ** 103 15 - - 83 12 - - - - - 62 9 - 213 7X---- 1 41 6 0 0 - - - - - 0 50 100 150 200 250300 350 400 450 500 550 600 650 700 750 gpm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 2280 2470 26602850 1pm 5 10 15 tps 1.5 3 4.6 mps Standards ASSE 1048, AWWA C510-92, CSA B64.5, UL 1469 Approvals UL Classified (OSY only), FM (sizes 21/2* - 10°, OSY only) G FM 4~ S UP. Appmed 11 MMMEMMMMMENEWME MENEEMENEEMEMME ••••u u•ui I••• I _•____..I NPAMOMMIM - - ..---- i•u I I ¶1 rn............ ti.......i uui u••••ii • i ........i i•• I -------- F -. -------- - ------ —----- t --------- SIZE (ON) DIMENSIONS NET WEIGHT NET WEIGHT in. mm in. A mm in. C (OSY) mm D in. mm ______________ G in. mm L in. mm P in. mm wiGates lb. kg. w/o Gates lb. kg. 21/2 65 37 965 16/8 416 31/2 89 10 250 22 559 12'I2 318 155 70 68 31 3 80 38 965 18/8 479 33/4 95 10 250 22 559 13 330 230 104 70 32 _4100 401016 22/4578 41/2 114 10250 22559 141/2 368 240109 7333 6 150 481/2 1232 301/8 765 51/2 140 15 381 27'/2 699 1 151/2 394 390 177 120 54 8 200 521/2 1334 373/4 959 6/4171 15381 291/2 749 18'/2464 572259 18082 10250 551/2 1410 453/4_1162 8200 15381 1 291/2 749 1 19'/2 495 774351 1 19086 12300 571/2 1461 53'/n 1349 9'/2 241 15381 1 291/2 749 1 21533 1 1044474 1 220100 A M E S •_9001 -2008 __ FIRE &WATERWORKS amesfirewater.com __ 2RTIFI ED ____ A Watts Water Technologies Company USA: Backflow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 Latin America: Tel: (52) 81-1001-8600 ES-A-3000SS 1410 © 2014 Ames Fire & Waterworks V3801 and V3802 FireLock® V38, K5.6 Models V3801, V3802 Adjustable Concealed Standard Spray Standard and Quick Response Approvals/Listings: L _PC B 04 umn 0832 104-la/02 See Victaulic Publication 10.01 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2f/13 mm adjustment to accommodate concealment needs. The 'standard" design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. \4taulicr 40.50 Technical Specifications: Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: 1/2 /13 mm K-Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: /2"/15 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. For K-Factor when pressure is measured in Bar, multiply Si. units by 10.0. Exaggerated far clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 \4tauIic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Material Specifications: Deflector: Bronze per UNS C22000 Cover Plate: Fusible solder Bulb: Glass with glycerin solution. Bulb Nominal Diameter: LI Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene Accessories: Installation Wrench: LI Concealed: V38-4 or V38-5 Sprinkler Finishes: LI Plain Brass (only) Cover Finishes: LI Chrome Plated LI White Painted3 LI Flat Black Painted3 LI Custom Painted3 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. 40.50 2558 Rev. 0 Updated 07/2014 02014 Victaulic Company. All rights reserved. victaulic.com 2 \)tauIic victaulic.com I Sprinkler I FireLockw I K5.6, V38 I Publication 40.50 Approval/Listings: Approvals/Listings Model V3801 V3802 Orifice Size (inches) 1/2" 1/2" Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor S.l. 8.1 8.1 Response Standard 5mm bulb Quick4 3mm bulb DefiectorType Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings F°/C° V3801 V3802 135 F/57 C 135 F/57 C 155F/68C 155F/68C cULus 175F/79C 175F/79C 200 F/93 C 200 F/93 C 155 F/68 C4 FM5 NONE 175 F/79 C4 200 F/93 C4 135 F/57 C 135 F/57 C NYC/MEA5 #62-99-E 155 F/68 C 155 F/68 C 175 F/79 C 175 F/79 C 200 F/93 C 200 F/93 C 135 F/57 C 135 F/57 C 155 F/68 C 155 F/68 C CSFM5 #7690-0531:112 175 F/79 C 175 F/79 C 200 F/93 C 200 F/93 C 155°F/68C Sprinkler/1 38°F/59°C Cover i 55°F/68°C Sprinkler/1 38F/59C Cover LPCB 175°F/79C Sprinkler/1 65°F/74°C Cover 175°F/79°C Sprinkler/1 65°F/74C Cover 200F/93°C Sprinkler/1 65°F/74°C Cover 200°F/930C Sprinkler/1 65°F/740C Cover 135 F/57 C 135 F/57 C 155F/68C 155F/68C VNIIPO 175 F/79 C 175 F/79 C 200 F/93 C 200 F/93 C 286 F/141 C 286 F/I41 C CCCf ZSTDY NONE 155 F/68 C For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 \JtauIic 2H//59 mm - victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 255'/68 mm E Max. Hole /60 nnnn in. Hole "— Finished Surface Minimum Extension Distribution Patterns: 8mm 35A,/8U mm 2®ra7l mm ½/l3 mm Adjustment , 3W/83 mm Cover Plate Maximum Extension 2/51 mm Typical Ceiling Pie - Finished Surface Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory uiaisuiaau iiu aiaauiaiiiu .uuIi uuuuuu iIiiIIINUIII IiIIIIiINIII iiu.uuuuIuI "III"' uuauuuiauIUL 2' 4' 6' 8' 10' 12' 14' 0.6 m 1.2 m 1.8 rn 2.4 m 3.0 m 3.7 m 4.3 m 7psi _.._.. 15 psi 30 psi ______ 48 kPa 103 kPa 207 kPa NOTES 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 \#tauIiC 10' 3.0 m 8' 2.4 m 6' 1.8 m 4 1.2 m 2' 0.6 m 0 victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -67°FI-55°C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature - F! C Temperature - F! C Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color Identification Rating Allowed Ordinary A 135 F/57 C 100 Ff38 C Orange A6 1358 57 100 57 Ordinary C 155 F/68 C 100 Ff38 C Red D7 165 74 10 65 Intermediate E 175 F/79 C 150 F165 C Yellow Intermediate F 200 F/93 C 150 Ff65 C Green High J 286 Ff141 C 225 F/107 C Blue Extra High 8 K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb 6 A For use with Standard or Quick Response Concealed Sprinkler 135°F/57°C or 155°F/68°C. D For use with Standard or Quick Response Concealed Sprinkler 175°F/79°C or 200°F/93°C. I 138°F/59°C per LPCB Note Custom Finish - Customer to provide paint specification, allow 4- 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent - V3801, V3802 V38-4 or V38-5 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 JtauIic0 victaulic.com I Sprinkler I FireLock5 I K5.6, V38 I Publication 40.50 WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: ME 001-610-559-3300. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victastic installation/assembly instructions. products for complete installation and assembly data, and are available in POE format Victaulic reserves the right to change product specifications, designs and standard on our websile at www.nictaalic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Zero-Flex are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 '/''ctauIic UlISA Tube'sO B SCHEDULE 10 PIPE SPECIFICATIONS 10 and Schedule 40 are FM Approved and UL Listed (for U.S. NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE and Canada), even though these SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE products do not require separate approvals and listings. Bull 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 Moose Tube made the decision 1-1/4 1.660 1.442 991 11.81 lbs/ft 2.518 61 to have them approved and listed. 1-11.2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 Our Schedule 10 and Schedule 40 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 have a pressure rating of 300 PSI 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 and have been through the same 3 3.500 3.260 3.54 434 lbs/ft 7.957 19 rigorous testing as our other fine 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 pipe products. Schedule 10 can be supplied roll grooved or plain end. SCHEDULE 40 PIPE SPECIFICATIONS Bull Moose Tube's® Schedule 10 111111111111r, and Schedule 40 pipes are hot NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE dipped galvanized to meet ASTM SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE A123 standards. All products are stencilled to meet FM & UL 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 specifications. 1 1/4 1 660 1.380 1.00 227 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 100 366 lbs/ft 5.114 30 2-1/2. 2,875 2.468 1.00 580 lbs/ft 7.M_ 30 3* : 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 'Only available in Casa Grande, AZ "Corrosion Resistance Ratio per latest UL Directory listing c®us LISTED AppRoval NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com C~3, 6, Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grand" DallaD( Masurti OH 63017 Dull Mooselube'sa Eddythread40 ADVANTAGES OF BULL MOOSE TUBED EDDYTHREAD 40® I) is a lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 psi. Resistance Ratio of 1. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 1111 MIC preventative coating. EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB/FT WEIGHT SIZE c®us LISTED APPROVED (;] 4f NFPA' 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 100 3.308 4.842 30 Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U l8ro Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa GraadAZ DallasjX MasurV OH 63017 5 Bull Moose Tube's Eddylite is a lightwall threadable pipe manufactured in NPS 1 'through 2". EddyliteO is truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylitee is manufactured to meet the requirements of ASIM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APP RU [;] 4A I NFPA' 6 ADVANTAGES OF BULL MOOSE TUBEa EDDYLITP Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASIM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 008 479 1.617 2,364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 016 431 2.617 4.230 37 .Corrosion Resistance Ratio per latest UL Directory Iis6n1 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q1 For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO kentwA Casa Grand AZ Dallas TX Masurtt OH 63017 Dull Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® LI is specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10 FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight -saves shipping costs and offers easier handling. as UL listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD Il® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NPS O.D. EDDY FLOW" EDDY FLOW@ WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR* PER FT. Wt SIZE an opportunity for downsizing and further cost savings.1-1/2 11/4 1.660 1.530 1.98 1.222 2.019 61 1.900 1.728 344 1 844 2.860 61 2' 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 - 4.968 11.290 19 Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED tiPPR0Vffl [;] 4 NFPA ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO KentWA Casa Grande AZ Dallat,TX Masury.OH 6301? 7 Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® U a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit° Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. 'With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WI. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1 00 1.604 3.344 37 'Presslir is a Registered Trademark of Victaulic Company of America Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling cus LISTED I assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROV8J ,4 ONAj For Additional Information Contact (800) 325-67 .buIImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com L NFPA' 1819 Clarkson Road Chesterfield. MO Gerald, MO Kent WA Casa Grande. AZ Dallao,IX Masurt OH 63017 8 NIPS (IN) 1 1-1/4 1-1/2 2 2-1/2 0.D. (in) 1.315 1.660 1.900 2.375 ID(n) 1.201 1.546 1.786 2.261 ULTRA EDDY EmptyWerghtOb/ft 0.868 1.107 1,274 1.604 Water-Filled WeightOb/Et) 1.359 1.920 2.360 3.344 CRR 217 140 111 100 OD.(ln) 1.660 1.900 2.375 2.875 3.500 4.500 ID(n) 1.530 1.728 2.203 2.705 3.334 4.310 EDDY FLOW L Empty Weight (lb/fl) 1.222 1 844 2.330 2.809 3.361 4.968 jWater -filled Werghttb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 CRR 198 344 278 7 166 100 100 0.0(m) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 0(n) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Empty Weight (bfft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 Water-Fliled Weight (lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 - [ (HR. 1 1527 991 776 627 492 354 250 r 0.6.(in) 1.315 1.660 1.900 2.375 .0(n) 1.137 1,482 1.712 2.177 EDDYLITE Empty Weight (lb/ft) 1.260 1.617 1'.967 2.617 Water Filled Wetght(lb/ft) 1,700 2.364 2.965 4.230 r CR0 013 008 012 016 0.D. (in) 1.295 1.650 1.900 2.375 EDDYTHREAD L - 1.083 1.418 1.645 2.123 400 EmpyWeight(lb/111' 1.461 2.070 2.547 3.308 Water-Filled Weight (lb/ti) 1.860 2.754 3.468 4.842 C.R.R.100 100 100 100 00(n) j 1.315 1660 1,960 23)5 2875 3.500 4.500 ['Th(in) 1049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE EmpWeigh 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 Water-Filled Weight(lb/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 i.oó 1.00 -tbb 1.00 1.00 10'0 - A A For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas, X Masury, OH 63017 c®os LISTED <*> APPROVED (;] 4f9 NFPA 9 c®us LISTED APPROVHJ (;] A NFPA' 10 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDYe 0.868 91 1,659 1,896 1,975 rSCHEDULE 10 1.410 91 2.695 3,079 3,208 1 EDDYLITES 1.260 91 2,408 2,752 2,867 EDDY1I1READ40 1.461 70 2,148 2,454 2,557 SCHEDULE40 ULTRA EDDY e 1.680 1.107 70 61 2,470 1,418 2,822 1,621 2,940 1,688 EDDYFL0W 1222 61 1565 1789 1,864 SCHEDULE1O 1.810 61 2,319 2,650 2,760 11/4 [EDDYLITE 1.617 61 [____2,071 2,367 2,466 [EDDYTHREAD40' 2.070 51 2,217 2,534 2,639 SCHE60LE40 2.270 51 2,431 2,778 2,894 [ ULTRA EODY 1.274 61 1,632 1,865 1,943 [ EDDY FLOW 1.844 61 2,362 2,700 2,812 SCHEDULE 16- 2.090 61 2,677 3,060 3,187 1-1/2 - EDDYLITE 1 967 61 2,520 2,880 3,000 EDDYTHREAD40 2.547 44 2,353 2,690 2,802 SCHEDULE46 ULTRAEDDY 2.720 1.604 44 37 . 2,513 1,246 2,872 1,424 2,992 1,484 EDDYFL0W 2330 37 1810 2069 2155 { SCHEDULE 10 2.640 37 ' 2,051 2,344 2,442 2 EDDYLITE 2.617 37 2.033 2,324 -, 2,421 EDDYTHREAD 4O 3.308 30 2,084 2382 2,481 SCHEDULE 40 r 66YFL0W 3.660 2.809 30 2,306 1,770 2,635 2,022 2,745 2,107 2-1/2 r SCHEDUL1' 3.530 30 2,224 2,542 2-648 - ISCHEDULE4O EDDY FLOW 5.800 3.361 3,654 1,341 4,176 1,533 4350 ' 1,596 3 [ si5W66i1d 4.340 19 1,732 1,979 - 2,062 SCHEDUIE40 E 156Y -FL6-V-P 7.580 4.968 1,024 1,982 3,456 2,265 - 3,601 2,360 4 SCHEDULE 10 5.620 19 2,242 2,563 2,670 SCHEDULE4O*T SCHEOULE10 10.800 9.289 10 4,309 1,951 4,925 2,229 5,130 2,322 1 8 ir SCHEDULE 10 AZ. 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande, BULL MOOSE ThEE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings MaxZone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Ci for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 1 0.75 1.00 125 1.50 1.75 2.00 2.25 1 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 1 809 648 531 455 381 40 40 40 1 40 37 34 31 29 28 26 25 24 4 1 1544 1 1235 1 1012 1 867 1 726 40 1 40 40 1 40 1 40 1 37 1 34 1 32 30 29 28 1 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 BC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe * Transverse Brace Spacing Size 20 ft. T25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 10.75 1.00 1.25 11.50 1.75 2.00 2.25 2.50 2.75 3.00 1 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 1114 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 L518414 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED <> APPROVE NFPA Q1 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, X Masurtt OH 63017 11 STYLE 922 The Style 922 Outlet-I provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, _PCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2O68kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade 'E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No, Submitted By Spec Sect Para__________ Location Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2009 VICTALJLIC COMPANY. ALL RIGHTS RESERVED. REV..G \4taulicf 10.52_i IPS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 r .. I1iilNlIiD1I.pflllflvflhllmrnta. 14 1/2 13A6 I 130 1.83 1.10 1 3.87 2.56 1.0 32 15 30.2 + 33.0 - 46.5 - 27.9 98.3 65.0 0.45 3/4 13A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1- 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 - 13/16 - 38.6 - - 55.4 1.42 1 1.95 27.9 1.22 98.3 4.08 j 65.0 2.56 j 0.54 1.2 11/2 ½ 40 15 30.2 36.1 49.5 31.0 j 103.6 65.0 0.54 ~ 1,io 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 i 2.30 1.22 4.08 f 2.56 1.3 25 30.2 1 41.7 58.4 1.66 2.19 31.0 1.46 103.6 4.60 65.0 1 2.56 0.59 1.3 2 1/2 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/4 1 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 J 116.8 65.0 0.64 1 25 13,16 30,2 - 1 A6 1.88 2.54 478 4645 1.91 2.44 1.46 37.14 1.71 4.60 116.8 I 5.40 2.56 LoS.0 I 2.56 1.5 - 0.68 1.6 2½ ½ 65 15 30.2 40.5L 610 414j260.0 .073 - 3/4 1,i6 1.89 1 2.44 1.71 5.40 2.56 1.6 20 1 30.2 1,10 48.0j 610 2.13 2.79 - 414 1.71 137.2J 5.40 65.0w 2.56 0.73 1,6 25 30.2 13A6 541 470.9 1.91 2.44 434 1.71 1372k 5.50 65.0 2.56 0.73 j 1.6 761 mm x ½ 15 30.2 1 40.5 610 414 139.74610± 0.73 1 3/16 34 ' 1.89 2.44 1.71 5.50 2.56 1.6 20 30 48.0610 414 130.7J 60.0 0.73 1,71 5.50 I 2.56 1.7 1 1 3/16 2.13 2.79 25 30.2 54.1 70.9 43.4 139.7 1 65.0 0.80 FireLock® Outlet-T STYLE 922 DIMENSIONS IIL i_Ill II 'L Aru !3•• I!h t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. 612009 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 10.522 \4taulic REV_G IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X04-c-ta -U1 i d REV_G 10.523 STYLE 922 INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaulic vIcTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 4; Ductile Iron Threaded Fittings SMITHCOOPER® INTERNATIONAL 1 1 !.1 io ii to ii cI ffl, ui Specifications - 1_lull <:branded ductile iron threaied fittings are UL Listed and FM Approved at 500 psi o Rated to 300 WSP QO Ductile iron castings conform tuASTM A53& C L US LISTED Fitting dimensions conicrm to ASME B16.3 Bushings and plugs conform to ASME B1614 < > Fittings are 100% air te:ted APPROVED NPT threads on all fittings confcrm to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degree 3 F Workin] Pressure, Nonshock psiG 300# Class Threaded Fittings -20t0:100 500 -- 153 500 203 480 253 460 300 440 350 420 400 400 330 450 500 330 550 340 6C0 320 65) 300 c®uS <> APPROVED LISTED Fig. 35E 3_900 Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 03 - 3/4 35E 3006 1.31 70 140 1 35E 3010 1.50 40 80 0.5 0 1-114 35E 3012 -1.75 25 50 1-1/2 2 35E3014 35E 3020 1.94 18 36 1.1 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 i!!•ZI1IIII! Fig. 35RE3 - 900 Reducing Elbow Size in I Part Number a urn er A in B in Packing Weight lb Inner Master 3/4x 1/2 35RE3006004 1.20 1.22 80 160 0.3 I 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 11/4x1/2 35RE3012004 1.34 1.53 35 70 05 1-1/4 x 3/4 351RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 351RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 -36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 - 2.51 6 12 2.2 2-1/2x2 I 351RE3024020 2.39 2.60 6 12 2.5 Fig. 35F3 -45° Elbow Size in Part Number ________ A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 - 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 - 1.29 25 - 50 0.7 1-1/2 35F3014 1.44 20 40 1.0 2 - 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in I Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 - 1.31 80 160 0.3 3/4 3513006 30 60 0.5 1 3513010 1.50 25 50 0.7 _1i1_. 351 3012 1.75 10 20 1.1 1-1/2 35T3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 8904456 • www.smithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1x1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 1x 3/4x1 35R13010006006 1.38 1.31T.45 35 70 - 0.6 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-114x1/2x1-1/4 1-1/4x3/4 35R13012004012 1.75 1.53 .75 25 50 0.9 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x3/4x1-1/4 35RT3012006012 1.75 1.62 - .7520 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x 1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35R13012010006 1.45 1.38 1.63 20 40 0.8 1114x1x1 35R13012010010 158 150 169 20 40 09 1-1/4x1x1-1/4 1-1/2x1/2 35R13012010012 1.75 1.69 1.75 15 30 1.0 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35R13014004014 7.94 1.66 1.94 12 24 1.2 1-1/2x314 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35R73014006012 1.94 1.66 1.88 20 40 1.1 = 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 11/2x1x3/4 35R13014010006 TA 175 16 32 09 1-1/2x1x1 35R13014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-114 35R13014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35R13014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 - 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35R13014012004 1.41 1.34 1.66 16 32 0.9 - 1-1/2x1-1/4x3/4 35R13014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2x1x2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 2x1-112x3/4 35R13020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 1 35RT3020014014 2.02 1.94 2.16 1 8 16 1.8 C I C®uS <> APPROVED LISTED Fig. 35RT3 - Reducing Tee Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packg_ Weight lb Inner Master 3/4x1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1x1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35BT3012010014 1.88 1.80 1.82 15 15 30 30 1.2 1.3 1-1/4x 1-1/2 35BT3012014 1.88 1.88 1.82 1-1/4x2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONALO • TOLL FREE 1-800-766-0076 • FAX (323) 8904456 • www.smithcooper.com 112 Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 - 3/4 35CP3006 - 1.63 100 200 0.2 1 35CP3010 35CP3012 1.75 60 120 0.4 1-1/4 - 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Ni Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35RC3010004 1.69 80 - 160 - 0.3 1x3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 -80 - 0.6 2x1 (not hex) 35RC3020010 2.81 20 40 1.0 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2x1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 35H83020014 1 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 -0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 353P3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 4 1 LN 1 0 fflo, P0004901 VO i Fig. 35CP3 - Straight Coupling with Ribs c(DUS <~> APPROVED LISTED Fig. 35RC3 - Hex Reducing Coupling Fig. 351113 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 - 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com A A Size in Part Number A in Packing Weight lb Inner Master 1 1-1/4 1-112 35X 3010 1.50 20 40 0.9 35X3012 35X 3014 175 12 8 24 -74-- 1.94 16 - 1.8 2 - 35X 3020 2.25 1 6 12 2.8 Size in Part Number A in Packing Weight lb Inner Master 1/2 35C3004 0.87 300 600 0.1 3/4 35C3006 0.97 200 400 0.1 1 35C3010 1.16 110 220 0.2 1-1/4 35C3012 - 1.28 70 140 0.4 1-1/2 2 35C 3014 1.33 50 100 0.5 - 35C3020 1_45 25 - 50 0_8 - 2-1/2 35C3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp h""o IIPi c®uS <E> APPROVED A A Fig. 35X 3- Cross LISTED Fig. 35RX3 - Reducing Cross Size in Part N umber u A in B in Packing Weight lb Inner Master 1-1/4x1 35RX3012010 1.58 15 30 1.2 1-1/2x1 35RX3014010 _1.67 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size i n Part Number A in Packing Weight lb Inner I Master 3/8 - 358C3003 0.75 100 200 0.3 1/2 358C3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 S A 114114 Y X- P R E S S Installs into Metal Deck, Purlin, or Tubular Steel 141 The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or pudin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press It° Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor baffler fabric. Less jobsde material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Watch a vkiaadnossfrstun\ wvw.itwbuiIdex.comJ 1/4' 8181922 XP 200 Sammy 1146 (22 ga) 185 (Luminaire) .027' X-Press 200 250 (Luminaire) .056, .125' 25 125 Metal Deck 850(2W Pipe) .027' 940 (2 'Pipe) 020' "3 3/8' 8150922 XP 20 Sammy 1146 (22 ga) 185 (Luminaire) .027 1475 (4 Pipe) 104' .125" 25 125 Metal Deck X.Press 20 250 (Luminaire) .056' 283 (Conduit &Cable) _ 1500(4" Pipe) .060" . <S' 3/8' 8153922 XP 35 Sammy X-Press 1783 (16 gal 250 (Lurnin:ire) 056: 1475 e) .125' 25 125 Pert/n 416 (Conduit & Cable) .059" r r 3/8' 8150922 XP 20 Sammy X-Press 1146 (22 ga) 850 (24 Pipe) Pre-Pour twctamIConcrete©3O00p 25 125 Metal Deck Post-Pour Range llLWC~35PCFfbs/ft) - Pre-Pour Structural Concrete @3000 psi Post-Pour Range II LWCS 35 PCF (thst fill E The SidewinderX-Press expands to provide horizontal attachment in: -16 ga -3/16" steel- pudin, tubular steel. 'Installs in seconds with Sammy X-Press It" Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof (SWXP) deck, tubular steel, or vapor baffler fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. 'Made in the U.S.A. j -Itehtcha WW Wmonhotuni\ c.'V-Fwww.itwbuildex.comJ L 3/8" 8293957 SWXP35 ' 1798 (16 gal 80 (Luminaire) .059" X-Press 35 ..416 (Conduit&(;able). V Q) 25 125 Purtin The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1. Please refer to the publication in its entirety for complete details on this product including data development, product specifications, general suitability, installation, corrosion and spacing and edge distance guidelines. US: http://submittals.us.hilti.com/PTGVoI2/ CA: http://submittals.us.hilti.com/PTGVoI2CA/ To consult directly with a team member regarding our anchor fastening products, contact Hilti's team of technical support specialists between the hours of 7:00am - 6:00pm CST. US: 877-749-6337 or HNATechnicalServices(hilti.com CA: 1-800-363-4458, ext. 6 or CATechnicalServiceshiIti.com Hilt!, Inc. 7250 Dallas Parkway, Suite 1000 Piano, TX 75024 1-800-879-8000 www.hilti.com 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Orderinci information Listings/Approvals KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor LLAODR~BS <g> -- APPROVRJ IndeDendent code evaluation IBC®/ Inc® 2015 IBC®/ IRC® 2012 IBC®/ IRC® 2009 IBC®/ IRC®2006 II Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dbs in. 1/4 Nominal embedment h 0 in. 1-5/8 2-1/2 Effective embedment he, in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size da eanch : : r he hnom hc Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2,3,4,5 Nominal Nominal Tension - 4N Shear - qv anchor embed. f = 2,500 psi f' = 3,000 psi f = 4,000 psi f' = 6,000 psi f' = 2,500 psi f' = 3,000 psi f = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2,3,4,5 Nominal Nominal Tension - Shear - anchor embed. f' = 2,500 psi f' = 3,000 psi f = 4,000 psi f', = 6,000 psi f, = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, A = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a5 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - a5 = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile' Shear' Seismic shear' diameter thread diameter qv V. in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1 / UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASO value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension (ON. = A,aNf as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with <0.64A,5 U as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with (PV_ :5 4 0.60 f., as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I err espatol 1-800-879-5000 1 Hilt (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete12 Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 uncracked concrete fIN fRN JAy IRS fRy JUV______ Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hflRy (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 _______ _______ 0.70 0.63 _______ 0.68 0.88 n/a '-- 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 1 0.66 0.97 1.00 0.81 CO 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) _______ _______ _______ _______ 1.00 0.86 _______ Ca 10 (254) 0.89 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 cracked concrete f fRN lAy fRy fRy JHV______ Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) _______ 0.89 _______ 0.77 0.68 1.00 0.85 zi 5 (127) 0.93 0.80 0.70 0.89 f 5-1/2 (140) 0.98 0.83 0.72 0.93 . 6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 8(203) 0.98 0.82 1 9 (229) 1.00 0.86 10 (254) 0.90 11(279) 0.94 12 (305) 0.98 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROMS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f v assumes an influence of a nearby edge. If no edge exists, then fAA = IAN- 4 Concrete thickness reduction factor in shear, f assumes an influence of a nearby edge. If no edge exists, then f iV = 1.0. EJ If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.ushiltLcom I en español 1-800-879-5000 1 Huh (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 'Mechanical Anchoring Systems 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWlK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6.7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Shear - 4V Tension - 4N Shear - On anchor thread embed. f'= 3,000 psi f= 4,000 psi f',= 3,000 psi f'= 4,000 psi f'= 3,000 psi f'= 4,000 psi f'= 3,000 psi f'= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N ___________ " Shear - Tension - N Shear - anchor thread embed. f'= 3,000 psi f'= 4,000 psi f'0 = 3,000 Ps f'= 4,000 psi f' 3,000 psi f'0= 4,000 psi f'= 3,000 psi f'= 4,000 Psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 _____ (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1/4 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by oN, = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth o,, = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espatoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 I KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Min. 3/4 Minimum 20 gauge steel deck (typical) Mm. 1-1/4 - Mm. 12 (typical) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor' .2 Nominal Internal anchor thread Tensile Shear' Shear' diameter diameter N r V in. (UNJC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = A N cp f R as noted in GSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V, < Asev 4 0.6 f,,. R as noted in GSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with v < A q, 0.6 f R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 II Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. da in. 1/4 (mm) (64) in. 1.18 1.92 Effective embedment2 het (mm) (30) (49) in. 1-5/8 2-1/2 Minimum nominal embedment2 h m (mm) (41) (64) in. 3-1/4 4-1/8 Minimum concrete thickness h ,,. (mm) (83) (105) in. 2.00 2.78 Critical edge distance cec (mm) (51) (71) Minimum spacing at critical edge distance in. 1.5 (mm) (38) in. 1.50 Minimum edge distance cmi,, (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) in. 2 2-7/8I Mininimum hole depth in concrete h0 (mm) (51) (73) psi 125,000 Minimum specified ultimate strength (N/mm2) (862) in 0.045 Effective tensile stress area A,,N (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 lb 3,370 Factored steel resistance in tension N er (kN) (15.0) D.6.1.2 lb 750 Factored steel resistance in shear Vsa D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic Vsareq (kN) (1.5) lb 725 Factored steel resistance in shear V 0.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V,,,,eq (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k,, - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k6,,1 - 7 0.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 qJpN - 1.0 D.6.2.6 Anchor category - - 3 1 0.5.3 (c) Concrete material resistance factor k - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 lb 665 1,645D.6.3.2 Factored pullout resistance in 20 MPa uncracked concrete" N pr,urCr (kN) (3.0) (7.3) lb 340 815 Factored pullout resistance in 20 MPa cracked concrete Np,cr (kN) (1.5) (3.6) 0.6.3.2 lb 275 815 Factored seismic pullout resistance in 20 MPa cracked concrete Np,eq (kN) (1.2) (3.6) 0.6.3.2 Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. For all design cases, qi,,,, = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (kom) or uncracked concrete (k,,,,,,,) must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section 0.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qi,,1, 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete' 2'345 Nominal Tension - N Shear - V, __________ f' = 20 MPa f = 25 MPa f', = 30 MPa f'c = 40 MPa f, = 20 MPa f = 25 MPa f' = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concrete 1,2,3,4,5 Nominal Tension - N Shear - V __________ f', = 20 MPa f', = 25 MPa f'c = 30 MPa f'c = 40 MPa f' = 20 MPa f', = 25 MPa f', = 30 MPa f', = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, l = 0.68; for all-lightweight, l = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - 0N,seis = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNseis = 0.75 See section 3.1.8.7 for additional information on seismic applications. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hiIti.com len español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck" 2'3'4'56'7 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Nr Shear - Vr Tension - Nr Shear - Vr anchor thread embed. f'c = 20 MPa f' = 30 MPa f' = 20 MPa f' = 30 MPa f' = 20 MPa f'c = 30 MPa f'c = 20 MPa f, = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 / UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck 1'2'34'5'6'7'8 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N Shear - V ___________ r Tension - N Shear - V anchor thread embed. f' = 20 MPa f = 30 MPa f' = 20 MPa f = 30 MPa f = 20 MPa f'c = 30 MPa f = 20 MPa f, = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,Ce, = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor - = 0.45 For the 1/42-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 - 1 Tested in accordance with FM Approval Standard for Pipe Ranger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Mm. effective embedment hef in. Allowable load' Ultimate load Tension lb Shear lb4'5 Tension lb Shear lb4'5 1/4-20 UNC 1-3/8 1 455 1 485 1,810 1 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-I Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 3.3.7 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information" Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty / box KH-EZ 1/4x1-5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1/16 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1A6 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max.loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 314" and 11/4" Throat Openings Component of State of California OSHPD Approved c us USTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2' and 5/8' rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8' pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.137.5599 • FAX: 951.737.0330 ii CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25- Surge Restrainer c®uS LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 /7 'N 'N X. COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved C@ us usmo Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8' thru 7/8' rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE.. CORONA. CA 92879 PH: 951.137.5599 • FAX: 951.137.0330 CUSTOMER SERVICE . 800.186.5266 www.toko.com Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) ::x nuts (74 in place of a knurl nut. ' Order By- Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Fig. 200-1I2. 200-/4 Fig. 200_21/2 to 200-8 Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B3170NF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut ©li°OLCcT c®uS LISTED ____ ____ 0_1/2 i 1/2" (15) /8-16 31/8"(79.4) 2/8" (66.7) 11 (5.0) 0-/4 3/4 (20) /a'-16 31/8' (79.4) 21/2" (63.5) 11 (5.0) 0-1 1" (25) /8'-16 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200-1/4 11/4" (32) /8"-16 33/4" (94.0) 2/8 (73.0) 13 (5.9) 200_11/2 11/2" (40) /8"-16 3/8" (98.4) 2/8' (73.0) 14 (6.4) 200-2 (50) /81-16 41/2" (114.3) (76.3) 15 (6.9) 200-2/2 21/2 (65) /81-16 5/8' (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /811-16 5/8" (149.1) 4' (101.6) 29 (13.3) 200-3/2 1 31/2 (90) /8"-16 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4' (100) /8"-16 7/81- (187.3) 5' (127.0) 35 (16.0) 200-5 (125) 1/2"_13 91/8'.(231.8) 61/4" (158.7) 66 (30.2) 200-6 (150) 1/2"_13 101/8° (257.2) 63/4' (171.4) 73 (33.4) 200-8 8' 1 (200) 1/2"_13 131/8' (333.4) 1 83/4 (222.2) 136 (62,3) Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COO ER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod C®US Size Range: Fig. 200 1/2" (15mm) thru 8" (200mm) pipe LISTED Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe / I44 I types and protect CPVC plastic pipe from abrasion. Captured design /''/ keeps adjusting nut from separating with hanger. Hanger is easily I I .;' ") I44 I \ \ installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig. 200-1 to 200-2 Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. - Fig. 200-i /2. 200-/4 Maximum Temperature: 650°F (343°C) Fig. 200-21I2 to 200-8 Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. " W'-P 200M8-1/2 rrr 31/8° (79.4) 2/a" (66.7) 11 (5.0) 200M10-1/2 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/41, (20) M8 31/8 (79.4) 21/2° (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2" (63.5) ii (5.0) 200M8-1 1° (25) M8 3 /8" 1 (85.7) 2/8° (66.7) 12 (5.5) 200Mb-1 1° (25) M10 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 11/4° (32) M8 33/4° (94.0) 2/8' (73.0) 13 (5.9) 200M10-11/4 11/4° (32) M10 33/4" (94.0) 2/8° (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8' (98.4) 2/8' (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3/8" 1 (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 2° (50) M8 41/2" (114.3) 31, (76.3) 15 (6.9) 200M10-2 211 (50) 1 M10 41/2" (114.3) 3° (76.3) 15 (6.9) 200M-21I2 21/2' (65) M10 5/8" (142.9) 4/8" (104.7) 27 (12.3) 200M-3 3 (75) M10 5/8" (149.1) 411 (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7/8' (187.3) 5/4' (133.3) 34 (15.6) 200M-4 4° (100) M10 7/8" (187.3) 5° (127.0) 35 (16.0) 200M-5 511 (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200M-8 8' (200) M12 13/8' (333.4) 1 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 24 ___ 1:ItTi T4.1.l1.:uJ C® US I uSTED 1 TT . . . . . . ...... .... A. ONO Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2"13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 1) 200H-2-3/8 2° (50) /8"-16 4/16" (115.9) 3I32" (81.7) 48 (21.8) 200H-2-1/2 2° (50) 1/2"13 423/32' (119.8) 33/8" (85.7) 45 (20.4) 200H-2112-318 21/2" (65) /811-16 5/16" (134.9) 3/32" (94.4) 59 (26.7) 20011-21/2-1/2 21/2° (65) 1/2"_13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"13 5/8" (148.1) 331/32" (100.8) 60 (27.2) 200114-3/8 1 4° (100) /8"-16 6/" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4" (0) 1/2"13 71/32" (178.6) 419/32" (1116.7) 73 ° Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COO ER B-Line FiGaskeii!ant pPI Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ° System Compatible Program* Certified to NSF/ANS/Std 61-G FOC/1. SYSTEM COMPATIBLE *FBC® System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 -- FAX + 1800 344-3775 Nu © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ", Blaze-Master®, FlowGuard Gold® and Conan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. 1_ ffiij E1 [I flNL F P P I® Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. F8CK SYSTEM COMPATIBLE *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. [ 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL +1 760 599-1168 +1 800 344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPI5, LubeFit5 are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMaster, FlowGuard Golds and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. - vv liI - v -M ITibsieaiI F1i tE-_ALTB1Titir1e:a:dLeJtthnrgith I F PP I® Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. L] ThFedFit Th,,d C,.Ol,,0 Oil Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBT/:~7. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. 0_0 Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. Nu © 2013 Fire Protection Products, Inc. FPPI, ThreadF,tA are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A.