Loading...
HomeMy WebLinkAbout2855 GAZELLE CT; ; FPC2017-0108; Permitj;1 l4rI .]Fi Uity of Carlsbad Print Date: 10/19/2021 Permit No: FPC2017-0108 Job Address: 2855 GAZELLE CT, CARI.SBAD, CA 92010-6670 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091201800 Track #: Applied: 05/02/2017 Valuation: $820,319.00 Lot U: Issued: 07/25/2017 Occupancy Group: Project U: DEV09042 Finaled Close Out: 07/29/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: IONIS PHARMACEUTICALS Description: lONIS DETACHED FITNESS CENTER - SPRINKLER <100(35 HEADS) Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC JAZZMIN DEEKEN 9925 PROSPECT AVE. USTE B 9925 PROSPECT AVE. U B SANTEE, CA 92071 SANJTEE, CA 92071 (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 System < 100 heads $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov - - - Fire Protection b, Computer Design AMERICAN AUTOMATIC FIRE 9510 PATHWAY ST. SUITE B SANTEE, CA 92071 619-562-3010 Job Name : ION IS FITNESS CENTER Building Location : 2855 GAZELLE COURT CARLSBAD, CA System : Contract Data File Ionis-Calculations-R1 .WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AMERICAN AUTOMATIC FIRE Page IONIS FITNESS CENTER Date 4.17.17 Hydraulic Desion Information Sheet Name - IONIS FITNESS CENTER Date - 4.17.17 Location - 2855 GAZELLE COURT CARLSBAD, CA Building - System No. - Contractor - Contract No. - Calculated By - Drawing No. - Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - 161 -0" Occupancy - FITNESS CENTER S ( ) NFPA 13 (X) Lt. Flaz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1266 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make TYCO D Area Per Sprinkler - 225 ( ) Dry Model TY3131 E Elevation at Highest Outlet - 16 ( ) Deluge Size 1/2' S Hose Allowance - Inside - 100 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - N Note Calculation Flow Required - 269.3 Press Required - 56.4 BASE OF RISER Summary C-Factor Used: 120 Overhead 140 Underground Water Flow Test: Date of Test - 4.16.17 Time of Test - Static Press - 96.3 Residual Press - 56.7 Flow - 7900 Elevation - -9.5 Pump Data: Tank or Reservoir: Cap. - Rated Cap.- Elev.- 8 Press - Elev. - Well Proof Flow W A T E R S U P P L Y Location - Source of Information - CARLSBAD FIRE DEPT. C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C AMERICAN AUTOMATIC FIRE Page 2 IONIS FITNESS CENTER Date 4.17.17 City Water Supply: Demand: Cl - Static Pressure : 96.3 Dl - Elevation : 11.044 C2 - Residual Pressure: 56.7 D2 - System Flow :169.259 C2 - Residual Flow : 7900 D2 - System Pressure : 65.344 Hose (Demand) :100 D3 - System Demand : 269.259 Safety Margin : 30.879 150 140 130 p120 R11° E 100 : S 90 s80 U 70 - -2- C2 D3 R 60 E 50 40 30 20 10 DT I I I I 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary AMERICAN AUTOMATIC FIRE Page 3 IONIS FITNESS CENTER Date 4.17.17 Fitting Legend Abbrev. Name ½ 3/4 1 11/4 1½2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zin Wilkins 450DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD AMERICAN AUTOMATIC FIRE Page 4 IONIS FITNESS CENTER Date 4.17.17 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 16.0 5.6 16.14 na 22.5 0.1 225 7.0 2 16.0 5.6 16.64 na 22.84 0.1 225 7.0 3 16.0 5.6 18.46 na 24.06 0.1 225 7.0 5 16.0 5.6 16.44 na 22.71 0.1 225 7.0 6 16.0 5.6 16.95 na 23.05 0.1 225 7.0 7 16.0 5.6 18.8 na 24.28 0.1 225 7.0 50 16.0 5.6 28.35 na 29.82 0.1 225 7.0 4 16.0 28.05 na 8 16.0 28.55 na 51 16.0 30.36 na 9 16.0 34.62 na TOR 16.0 42.99 na BOR 1.0 56.45 na 100.0 UG1 -3.0 58.23 na BF1 -3.0 58.71 na BF2 -3.0 62.2 na UG2 -3.0 62.42 na UG3 -6.0 63.73 na UG4 -6.0 63.8 na SRC -9.5 65.34 na The maximum velocity is 14.43 and it occurs in the pipe between nodes 7 and 8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 AMERICAN AUTOMATIC FIRE Page 5 IONIS FITNESS CENTER Date 4.17.17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn 1 22.50 1.408 0.0 12.900 16.143 K Factor = 5.60 to 120.0 0.0 0.0 0.0 2 22.5 0.0386 0.0 12.900 0.498 Vel = 4.64 2 22.84 1.408 0.0 12.900 16.641 K Factor = 5.60 to 120.0 0.0 0.0 0.0 3 45.34 0.1411 0.0 12.900 1.820 Vel = 9.34 3 24.07 1.408 1 J 6.617 24.300 18.461 K Factor = 5.60 to 120.0 0.0 6.617 0.0 4 69.41 0.3101 0.0 30.917 9.588 Vel = 14.30 0.0 69.41 28.049 K Factor = 13.11 5 22.71 1.408 0.0 12.900 16.440 K Factor = 5.60 to 120.0 0.0 0.0 0.0 6 22.71 0.0392 0.0 12.900 0.506 Vel = 4.68 6 23.05 1.408 0.0 12.900 16.946 K Factor = 5.60 to 120.0 0.0 0.0 0.0 7 45.76 0.1435 0.0 12.900 1.851 Vel = 9.43 7 24.28 1.408 1 J 6.617 24.300 18.797 K Factor = 5.60 to 120.0 0.0 6.617 0.0 8 70.04 0.3154 0.0 30.917 9.750 Vel = 14.43 0.0 70.04 28.547 K Factor = 13.11 50 29.82 1.408 1J 6.617 24.300 28.348 K Factor= 5.60 to 120.0 0.0 6.617 0.0 51 29.82 0.0650 0.0 30.917 2.009 Vel = 6.14 0.0 29.82 30.357 K Factor= 5.41 4 69.41 2.203 0.0 14.200 28.049 to 120.0 0.0 0.0 0.0 8 69.41 0.0351 0.0 14.200 0.498 Vel = 5.84 8 70.03 2.203 0.0 14.200 28.547 to 120.0 0.0 0.0 0.0 51 139.44 0.1275 0.0 14.200 1.810 Vel = 11.74 51 29.82 2.203 1J 11.593 11.800 30.357 to 120.0 0.0 11.593 0.0 9 169.26 0.1824 0.0 23.393 4.266 Vel = 14.25 9 0.0 2.203 21 9.547 36.300 34.623 to 120.0 0.0 9.547 0.0 TOR 169.26 0.1824 0.0 45.847 8.362 Vel = 14.25 TOR 0.0 2.203 1 8.183 15.000 42.985 to 120.0 1S 15.003 23.186 6.496 BOR 169.26 0.1824 0.0 38.186 6.965 Vel = 14.25 0.0 169.26 56.446 K Factor = 22.53 BOR 269.26 5.86 1 E 15.749 4.000 56.446 Qa = 100 to 140.0 0.0 15.749 1.732 UG1 269.26 0.0028 0.0 19.749 0.055 Vel = 3.20 UG1 0.0 5.86 3E 47.247 125.800 58.233 to 140.0 0.0 47.247 0.0 BF1 269.26 0.0028 0.0 173.047 0.478 Vel = 3.20 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AMERICAN AUTOMATIC FIRE Page 6 IONIS FITNESS CENTER Date 4.17.17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn BF1 0.0 6.16 3E 60.252 12.000 58.711 to 140.0 iZin 0.0 60.252 3.337 * * Fixed Loss = 3.337 BF2 269.26 0.0022 0.0 72.252 0.156 Vet = 2.90 BF2 0.0 5.86 1E 15.749 27.000 62.204 to 140.0 1G 3.375 52.872 0.0 UG2 269.26 0.0028 iT 33.748 79.872 0.221 Vet = 3.20 UG2 -203.30 9.42 iT 49.229 327.800 62.425 to 140.0 0.0 49.229 1.299 UG3 65.96 0.0 0.0 377.029 0.008 Vel = 0.30 UG3 0.0 7.68 SE 99.262 1196.000 63.732 to 140.0 iT 38.602 137.864 0.0 UG4 65.96 0.0001 0.0 1333.864 0.073 Vet = 0.46 0.0 65.96 63.805 K Factor = 8.26 UG2 203.29 9.42 1E 21.661 425.600 62.425 to 140.0 1 49.229 70.890 1.299 UG4 203.29 0.0002 0.0 496.490 0.081 Vel = 0.94 UG4 65.97 11.2 1E 26.318 117.400 63.805 to 140.0 1 58.484 84.802 1.516 SRC 269.26 0.0001 0.0 202.202 0.023 Vel = 0.88 0.0 269.26 65.344 K Factor = 33.31 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2855 Gazelle Court CITY: Carlsbad PHONE: (619) 562.3010 (AAFS, Inc.) FAX NUMBER: (619) 562.8094 Largest Building (ft.2): Sprinkled? Construction Type:_________________ SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): end of Gazelle Court TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 107 PSI Hydrant Number (if applicable):H61674 Elevation of test: 453 Feet Date/Time of Test': 1 rPitot Tube Readin PS11 çorresponding Flow - GPM] Total Flow: 7,900 GPM Residual Pressure 63 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this exceeds the District's maximum velocity criteria of 15 fps. Therefore, the maximum allowable fire flow for this site is 7,900 gpm. 1Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:________________________________________ /_ Title/Org: P( _ctManager Date: 04/16/2017 Model 7000 Model 7200 MODEL SIZE A B C 7000 ½" 1/4" 1" 35A6" (44 mm) (25 mm) (83 mm) 7200 ~" 1A" 1" 35A6" (44 mm) 1 (25 mm) 1 (83 mm) From the 2013 Edition of NFPA 13 Pressure Relief Valves Model 7000 & Model 7200 100 Quaker Lane, Malvern, PA 19355 • Phone: 610-240-4900 • Fax: 610-240-4906 • www.agfmanufacturing.com Sizes: 1//211 3,1411 LISTED APPROVED AGE Manufacturing Model 7000 and 7200 Pressure Relief Valves are designed specifically for all wet fire sprinkler systems*. Both models relieve excess system pressure caused by surges or temperature changes. The Model 7000 and 7200 comply with the requirements of NFPA 13 that stipulate a pressure relief valve must be installed on all wet systems and downstream of all pressure reducing valves. The Model 7000 has a 1/2" MlPT inlet and FIPT outlet and is featured on our Models 1011A, 1011 T, 2511 A, and 2511 T TESTANDRAIN® valves, Models 3011 A and 3011ASG INSPECTOR'STEST® valves, and lh/4"_6" Model 8011 RlsERPACKTM assemblies. The Model 7200 has a 3/4" MIPT inlet and FIPT outlet and is included with our 1" Model 8011 Residential RIsERPACKT. Features IN, Factory rated 175 PSI** UL Listed and FM Approved. Bronze body with stainless steel spring. IN, Integral flushing handle removes debris that causes leaks through the valve seat and disc. 165 PSI, 185 PSI, 195 PSI, 205 PSI, 225 PSI, and 250 PSI ratings are also available for the Model 7000. *Chapter 7.1.2.1 - Unless the requirements of 7.1.2.2 are met, a wet pipe system shall be provided with a listed relief valve not less than ½ in. (12mm) in size and set to operate at 175 psi (12.1 bar) or 10 psi (0.7 bar) in excess of the maximum system pressure, whichever is greater. Chapter 7.1.2.3 - A relief valve per 7.1.2.1 shall be required downstream of check valves required by 8.17.5.2.2(1). Chapter 8.16.1.2.3* - A listed relief valve of not less than ½ in. (13mm) in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding the rated pressure of the components of the system. Chapter A.8.16.1.2.3 - Where the relief valve operation would result in water being discharged onto interior walking or working surfaces, consideration should be given to piping the discharge from the valve to a drain connection or other safe location. MADE IN U.S.A. "NOTE: UL and FM standards for sprinkler system pressure relief valves require relief valves to operate within a range of their ratings. FM requires a relief valve to OPEN at a pressure no less than 85% of their rating and UL requires OPENING at a pressure no greater than 105% of their rating. Both standards require the relief valves to CLOSE within a percentage below OPEN. Choose the relief valve comparing static pressure to 90% of the relief valve's rating to determine the estimated minimum OPENING and 80% of the relief valve's rating for approximate maximum CLOSING. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTDRAIN is a registered trademark of AGE Manufacturing, Inc. SellSheet-7000-7200 . 3/17 TESTANDRAIN® Model 1011 Model 1011 Model 3011A Model 3011ASG Model 2511A Model 2511T RISERPACK -r 'The Model 7000 Pressure Relief Valve is available with the following ratings: F F F F F F F 165 PSI 175 PSI 185 PSI 195 PSI 205 PSI 225 PSI 250 PSI The Model 7000 Pressure Relief Valve is also used on the Following AGF Products The Model 7200 Pressure Relief Valve is used on the Following AGF Product Residential RIsERPACK 1" Model 8011 11/4"_6' M8011 Commercial & Residential RIsERPACK AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Job Name: Architect: Engineer: Contractor: tqco Fire Protection Products Worldwide Contacts Series TYFRB - 2.8,42,56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in this data sheet are quick response, standard coverage, deco- rative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. EEM The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NOVEMBER 2015 Sprinkler Identification Number (SIN) TY1131 - Upright 2.8K, 1/2" NPT TY1231 - Pendent 2.8K, 1/2- NPT TY2131 - Upright 4.2K, 1/2" NPT TY2231 - Pendent 4.2K, 1/2" NPT TY3131 - Upright 5.6K, 1/2" NPT TY3231 - Pendent 5.6K, 1/2" NPT TY4131 - Upright 8.0K, 3/4" NPT TY4231 - Pendent 8.0K, 3/4" NPT TY4831 - Upright 8.0K, 1/2" NPT TY4931 - Pendent 8.0K, 1/2" NPT TFPI7I 2-7/8 (73,0 mm) DIA. RECESSED PENDENT * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 1/2 NPT* UPRIGHT - TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE I 7/16" (39,7 mm) (11,1 mm) NOMINAL 2-1/4MAKE-IN (57,2 mm) 2-3/16" 1-9/16 ____ (55,6 mm) I 1/2 NPT** WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing JSS. CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS - 2.8 K-FACTOR, 1/2 INCH NPT * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. ESCUTCHEON PLATE SEATING SURFACE 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* 7/16 (11,1 mm) NOMINAL ..(55,6 mm) 2-3/16 I MAKE -IN 2-3/16 1-1/2' I (38,1 mm) (55,6 mm) 1/2 NPT** I WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON III H— 2-7/8' (73,0 mm) DIA. —H RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16' _ :11,1 mm) MAKE-IN (55,6 mm) JOMINAL 2-3/16 2-3/16 1-1/2 (38,1 mm) I (55,6 mm) WRENCH STYLE 10 or 20 FLATS RECESSED PENDENT ESCUTCHEON CROSS SECTION [.-.--- 2-7/8' (73,0 mm) DIA. - RECESSED PENDENT FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT TFPI7I Page 3 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE Lq~ 1/2" _ (12,7 mm) MAKE-IN 2-1/4' (58,7 mm) 1-9/16" NOMINAL ////q;JJ 2-5/16" (39,7 mm) (57,2mm) 3/4' NPT** WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS - 8.0 K-FACTOR, 3/4 INCH NPT UPRIGHT CEILING PLATE SEATING SURFACE 2-1/4" "I (57,2 mm) 2-3/16" 1-9/16" (55,6 mm) 1 (39,7 mm) H WRENCH FLATS I!' 1 - Frame 5 - Compression 2 - Button Screw 3 - Sealing 6 - Deflector * Assembly 4 - Bulb * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. - PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END "B' USED FOR 3/4" NPT MODELS) FIGURE 6 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 W-TYPE 7 RECESSED SPRINKLER WRENCH V TFPI7I Page 4 of 10 Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion- resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 gpm/psV (40,3 1pm/bar1/) K=4.2 gpm/psi½ (60,5 1pm/bar½) K=5.6 gpm/psi'° (80,6 1pm/bar½) K=8.0 gpm/psi'12 (115,2 1pm/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table D. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8).....................Bronze Operation The glass bulb Contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft, lbs. (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 6). With ref- erence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 7). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED POLYESTER*** 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY113I) 135°F (57°C) Orange 1, 2, 3, 4 Blue 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY1231)° Figure 8 135°F (57°C) Orange 1,2,4 Green 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green RECESSED PENDENT (TY1231)** Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (1Y2131) 135°F (57°C) Orange 1,2 Green 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY2231)* Figure 10 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY2231)** Figure 11 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS PLATED I CHROME POLYESTER'LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C) Orange 1, 2, 3,4, 5, 6,7 Blue 1,2, 3,5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)* Figure 12 135°F (57°C) Orange 1, 2, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)** Figure 13 135°F (57°C) Orange 1,2,3, 4,5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C) Orange 1, 2, 3,4, 5, 6, 7 Blue 1,2, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)* Figure 14 135°F (57°C) Orange 1, 2, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)** Figure 15 135°F (57°C) Orange 1,2,3, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 80 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C) Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME POLYESTER LEAD FACTOR BRASS PLATED COATED PENDENT(TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) and 5.6 UPRIGHT (TY3131) 250 PSI (17,2 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) PENDENT (TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and 175 PSI (12,1 BAR) (12,1 BAR) UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing afire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but TABLE C MAXIMUM WORKING PRESSURE have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers -before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. TFPI7I Page 8 of 10 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4" (19,1 mm) I (15,9±6,4 mm) I 1/4 (6,4 mm) I / FACE OF 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER 7_ PLATE FITTING 1/8 - __ - 1/ (3,2 mm) -_ _ ___ ___ $ MOUNTING SURFACE 1-5/16" (33,3 mm) CLOSURE SERIES TY-FRB 13/16" (20,6 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON - 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8 DIA. 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 m CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (127±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE 1/8 FITTING 1/ I (3,2 mm) __ 2J MOUNTING SURFACE $ (33,3 CLOSURE SERIES TY-FRB 1-1/16" (27,0 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8 DIA. - (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF [E572 mm) ?i MOUNTING SPRINKLER PLATE FITTING 1/8 (3,2 mm) 7-I y . MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 9 of 10 2-7/8 DIA. 5/8±1/4 (73,0 mm) I 3/4(19,1 mm) I (159±6,4 mm) 2-1/4 DIA. 1/4(6,4 mm) MOUNTING PLATE SPRINKLER FITTING / FACE OF - (57,2 mm) MOUNTING - glizz, J (3,2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. -i 5/8±1/4" (73,0 mm) j 3/4 (19,1 mm) (15,9±6,4 mm) - 2-1/4 DIA. 1/4 (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER I PLATE ) 1/8 FITTING (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 13/16" (20,6 mm) FIGURE 14 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. (73,0 mm) 1/2±1/8" I 1/2" (12,7 mm) (12 7±3,2 mm) I 1/4(6,4 mm) FACE OF 2-1/4° DIA. I MOUNTING SPRINKLER PLATE FITTING 57,2 1/8' (3,2 mm) MOUNTING SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 1/2±1/8" (73,0 mm) 1/2 (12,7 mm) (12,7±3,2 mm) - 2-1/4' DIA. 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8 \ (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 1-1/16" (27,0 mm) FIGURE 15 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT .1 1 NATURAL BRASS - PURE WHITE POLYESTER (RAL901O)1 - SIGNAL WHITE POLYESTER (RAL9003) JET BLACK POLYESTER (RAL9005)2 7 LEAD COATED 9 I CHROME PLATED TFPI7I Page 10 of 10 P/N 57-XXX-X-XXX SPRINKLER SIN FINISH 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.81K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.21K PENDENT (1/2"NPT) TY2231 370 5.61K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.01K PENDENT (1/2"NPT) TY4931° TEMPERATURE RATINGS I 135 155 I 155-F (68-C) 175 I 175°F(79°C) 200 I 200°F (93°C) 286 I 286-F (141-C) NOTES: Eastern Hemisphere sales only. Available in only 2.8K, 4.2K, and 8.0K, 155F (68CC) and 200F (93CC); requires lead time to manufacture. TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 * Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright© 2015 Tyco Fire Products, LP. All rights reserved. - tqca TEFLON is trademark of The DuPont Corporation. Fire Protection Products FirëLock® Butterfly Valve \4taulicr Series 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12/50 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS USTED 0410001 104j/04 NOTES Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.81 5662 Rev H updated 03/2017 © 2017 Victaulic company. All rights reserved. 1 '.JtauIic vjçuic.com S 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa io up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psil2068kPa up to 300psi/2068kPa n/a up to 300 psif2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 2 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 1 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS— MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6'750 - 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"I200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TEE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 2-8/50-200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing El 10 - 12/250 - 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev H Updated 03/2017 © 2017 victaulic Company. All rights reserved. victaulic.com 2 JtauIic victaglic.com ¶ I 4.0 DIMENSIONS Series 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 425 228 641 400 422 450 212 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 - - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3.000 377 228 754 - 400 422 450 177 761 mm 76.1 95.8 57.9 191,5 - 101.6 1072 114.3 45.0 3 3.500 3.77 2.53 7.79 - - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 4.250 4,63 2.88 8.81 - - 5.50 4.22 4.50 2,20 10 8mm 1080 1176 732 2238 1397 1072 1143 559 4 4.500 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5.88 3.35 10.88 - 6.56 6.19 6.30 2.58 13 3mm 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 5.500 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 139.7 mm 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 - 6.56 6.19 6.30 2.58 1413 1413 1494 851 2764 1666 1572 1600 655 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159mm 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 - 65.5 6.500 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 165.1 1651 1494 975 2891 104 1910 1572 1600 655 6 6.625 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37,3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 - 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 1 228.6 __ 12 12.750 6.50 7.36 16,64 2.30 2.80 14.25 8.10 9.00 - 323.9 323.9 165.1 186.9 422,7 58.4 71.1 362.0 2051 NOTE Optional W/15 mm tap available. Contact Victaulic for details. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4 tauiic 4 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic company. All rights reserved. victaulic.com ,h1tauIic victajic .com ' I 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/rn inches inches of pipe 2 2.375 6 50 60.3 1.8 2½ 2.875 6 65 73.0 1.8 3.000 76.1 mm 76.1 18 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 284 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 5.500 12 139.7 mm 139.7 3.7 6 6.625 14 150 168.3 4.2 14 159 mm 159 mm 4.3 6.500 165.1 mm 14 165,1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 - 12 12.750 19 300 323.9 5.8 5 10.81 5662 Rev H Updated 03/2017 © 2017 victaulic Company. All rights reserved. victaulic.com 'Ltauiic victatilic.com 5.1 PERFORMANCE Series 705 Cv values for flow of water at +60°F/+160C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K values = Q2 Where: = Q2 Q = Flow (GPM) v AP = Pressure Drop (psi) Q = C x C= Flow Coefficient Q = K Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches CV mm mm 2 2.375 170 50 60.3 21/2 2.875 260 65 73.0 76.1 mm 3000 76.1 260 3 3.500 44 0 80 88.9 4 4.500 820 100 114.3 108mm 108 mm 820 5 5.563 1200 125 141.3 133 mm 133 mm 1200 rl- 139.7 mm 5.500 1200 197 6 6.625 1800 150 168.3 159 mm 159 mm 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 000 300 323.9 Where: Q = Flow (M3 /hr) AP = Pressure Drop (Bar) K = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches K mm mm 2 2.375 147 50 60.3 21/2 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108 mm 108 mm 710 5 5.563 1040 125 141.3 133 mm 133 mm 1040 139.7 mm 5.500 1040 139.7 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 7790 300 323.9 victa 5i11c .com 6.0 NOTIFICATIONS %law Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage.. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC Switches supervise the valve in the "OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = 51 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Si Normally Closed: (2) Blue Common: (2) Yellow S2 f Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe UL LISTED JUNCTION BOX CONDUIT lWNIT CONDUIT CONNECTORS WIRE NUTS FIRE ALARM TO END-OF-LINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR SUPERVISORY CIRCUIT COM. SWITCH CONTACT PJsflNG: 1 TA AT 125 AND 2SOVAC, 5, BELL 0.5A AT I2SVDC, OR 0,25 AT 250 VDC VOLTAGE SOURCE HORN Switch 1 2 leads per terminal Switch 2 1 lead per terminal NOTES The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe - 52) and the normally closed terminal (blue - Si and blue-with-orange stripe —S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81 5662 Rev H updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com jtauIicr victatHic.com 7.1 REFERENCE MATERIALS 10.01: Reference Guide 2901: Terms and Conditions/Warranty -100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries, Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic,com, Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details, Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/sr its affiliated entities, in the U.S. and/or other countries, 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved, victaulic.com 7 xArctauhil P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING Part #077-........ SIZE - SYSTEM PIPE: Nominal Pipe Size Sch. 40 Steel 1" - 8" Sch. 10 Steel 1 1/4" - 8" MATERIAL - Carbon Steel or S.S. (Type 304) FINISH - Plain or E.G. LISTING/APPROVAL - C@UI 203A-EX 2625, 203-EX 2551 USTED OSHPD OPA-0601 See Website. FUNCTION - Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions and NFPA 13. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Align brace member parallel through 410 fastener flanges. Tighten 1/2" bolts to 40 lb-ft. ORDERING - Part #, size - system pipe and finish. ® Listed Max. Horizontal Load 1"- 4" 1000 6"- 8" 1 2015 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 7/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL K 5 thru 12 Inch pipe SIZE -SYSTEM PIPE: Nominal Steel 1" thru 12" * Steel Specially listed - see chart. CPVC 1" thru 3". Brace common O.D. - Copper, Plastic, FRP, Ductile and Cast Iron SIZE - BRACE PIPE: 1" thru 2" Sch. 40 Mm. 11/4" required for 12" system pipe MATERIAL - Carbon steel and ductile iron. FINISH - Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL - 203A EX 2625 USTED le> FM Approved - 1950 OSHPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented - designed for system pipe of varying material. * Improved assembly - extra large bore for brace pipe. * Visual inspection, verifies proper installation. * Superior load ratings. ORDERING - Part #, size - system pipe, size - brace pipe and finish. ® Listed Max. Horizontal Load System NPS Sch. 30"-44" 45"-59" 60"-89" 90" 1°-i 1/2' 10-40 1383 1956 2394 2765 2"- 4" 10 13831956 2394 2765 iQ 1383 1956 2394 2765 1383 i 2 27 10" 10-40 1383 1956 2394 2 765 12" 40 70 2645 3238 11 Certified Max. ASD Horizontal Loads System Sch. 30n44 45"-59" 60"-74" 75"-90" NPS 1"-1 1/2" 10.40 1680 20 2920 3250 2-3" 10,40 1800 2350 3120 3490 4" 10,40 1370 1 1930 2370 2640 5", 6,8" 10,40 730 1040 1270 1420 * SPECIALLY LISTED PIPE A ST Pipes PVT LTD Al Juzeern Steel Products Co. SAOG Allied Tube & Conduit Corp. Bihar Tubes LTD. Bluesteel Services L L C Borarsan Mannesmann Born AS Boll Moose Tube Co. Conures Metal Supply LTD. Hai Chin Worldwide LTD Hickman Pipe & Tube Corp. Jiedo,,g Economy Development Testing Zone Jindal Industries LTD Jutindru Steel & Tubes LTD Mittal Canada Inc. MS Pipe Co. LTD Northwest Pipe Co. Pacific Pipe Public Co. LTD Saha Thai Steel Pipe Public Co. LTD Shield Fire Safety & Security LTD Suryn Roshini LTD Swnstik Pipes LTD Tex-Tube Cu. Universal Take & Plastic Industries LTD Weifung East Pipe Industry Technical Co. LTD Welded Tube - Berkeley LLC Wheatland Tube Co. Wit Div. Yieh Phui Enterprise Co. LTD Youngstown lobe Co. Zenith Birla (India) LTD * COMMONLY KNOWN AS SCH. 7 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When condition exists - shift mounting location. Specific AFCON products are exclusively designed to be Compatible ONLY with other AFCON products including ports and fasteners, resulting in listed sway brace, restrainer or hanger assembly. Be advised the following womanly restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of ifs products when used in combination with other products, parts or systems out manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages crony kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 3/13 Lá5!!kcj P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org ATTACHMENT FITTING LOCKING 9/16 DIa. SIZE - BRACE PIPE: 1" and 1 1/4" Sch. 40 MATERIAL - Carbon Steel or S.S. (Type 304). FINISH — Plain or E.G. LISTING/APPROVAL - Part #077—......_ rt#078 C®Us 203A-EX 2625 '&" FM Approved - 1950 OSHPD See Website. LISTED FUNCTION — Structure attachment fitting of an AFCON sway brace assembly. Common transition component with 411 sway brace fitting — see drawing Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8. Load rating - see chart. DO NOT BEND - If angle required use part 070, 075, 076 or 077. ASSEMBLY Combine with proper AFCON components- see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * Visual inspection, verifies proper installation. * Bolt hole fits 410/411 sway brace fitting. ORDERING - Part #, size - brace pipe and finish. ® Max. Horizontal Load 30°-44° 450590 600-890 906 1008 1 1425 1 1745 2015 4 Max. Horizontal Load 300-4401 450-59-1 600-740 75--90- 430 6207 760 1 940 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCONwill NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited In loss of business or profit, when non-AFCON products have been, or are used. 4/14 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX- 1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .1 7A 94 78 6(150) I20VAC PBAI206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* 1 .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK- 1 or BBX- I. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 . www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-I PAGE 1 OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance 53/4" (\ - L__. 33/8" 51, (146) -.._.1 (86) (127) (41) 4 1/4" (108) DWGO 776-2 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 A.C. BELLS WHITE (IN) WHITE (OUT) - 1" FROM CONTROL (2 PANEL OR C PRECEDING BELL (20) (10) BLACK (IN) IAK (OUT) CAUTION, WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. H (68) DWGII 776-I NOTES, I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. SWG# 776.3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. 65400776- REV Y-1 PAGE 2 OF 2 01/13 VSR (DPOTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2' DNSO VSR-2 1144402 2 1/2' DN65 VSR-2 1/2 1144425 3' DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 4' DN100 VSR-4 1144404 5' - VSR-5 1144405 6' DN150 VSR-6 1144406 8 DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adlustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved, LPCBApproved,For CE Marked (EN12259-5) / VdSApproved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM)- UL Maximum Surge: I8 FPS (5.5m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 3OVDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTION I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. 45401146 - REV L PAGE 1 OF 4 3/09 VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6' (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. DO NOT LEA VE CO VER OFF FOR Retard Adjustment "' EXTENDED 0ji Fig. I PERIOD OF liME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms Y TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect P e O (3 ROLL PADDLE IN OPPOSITE DIRECTION DIRECTION J OF WATERFLOW I owing waierac activates device in one direction only) DWG. 1146-11 ADAPTER ADApTER 20mm *2mm MAX. DNSO ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWG/* 1146-IF Compatible Requirements _Pipe/ _Installation Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm fl-lb n-rn VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 I.25+.125/-.062 33.0±2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 1 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ±.125 50.8 ± 2.0 VSR-3 1/2 3.5 - 4.000 1 101.6 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 0.134 3.40 0,258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 1 3.76 1 0.322 8.18 1 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. 45401146 - REV L PAGE 2 OF 4 3/09 (E)POTTER The Symbol of Protection Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. NOTICE Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. ME Fig. 7 Mounting Dimensions 3.50 in 2.00 (508 PIPE DIA. U-BOLT NUT + 5,25 in (+133.4mm) A234,~ U-BOLTWASHER PIPE SADDLE PLASTIC PADDL OWn 1116-14 Fig. 8 GREEN GROUND SCREWS tnI.g VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal rJ1 1(0 MG. ff1146-I6 uninsulated section of a single conductor should not be looped nd the terminal and serve as two separate connections. The must be severed, thereby providing supervision of the nection in the event that the wire become dislodged from under terminal. Failure to sever the wire may render the device 2erable risking severe property damage and loss of life. not strip wire beyond 3/8' of length or expose an uninsulated ductor beyond the edge of the terminal block. When using nded wire, capture all strands under the clamping plate. Fig. 5 Typical Electrical Connections Notes: The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). 'U! POWER SOURCE SUITABLE FOR BELL OWO. 1146.12 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR ON 50- ON 652-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR ON 80- ON 200 3-8 in PRINTED IN USA MFG. #5401146 - REV L PAGE 3 OF 4 3/09 (E)POTTER VSR VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 6 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTH[N SECTION OFCOVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY / Aul (2) LOCATING PINS fl t DO NOT REMO\ (2) RETARD HOL SCREWS (2) LOCATD BOSSES IN DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV L PAGE 4 OF 4 3/09 Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ____________ Pressure _ Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar psi bar -200 to 1500 -28.90 to 300 65.60 20.7 500 34.5 600 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31' 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 550° 287.8° - - 130 9.0 1 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c®us <:i3~> APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 ___________ Sizes '/4 -1" (6-25 mm) Sizes 11h'-2" (32-51 mm) Sizes 2'/x -3" (64-76 mm) ("F) (°C) psi bar psi bar psi bar psi bar -200 to 1500 -28.90 to 300 20.7 2,000 65.60 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 3500 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41,4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 5500 287.8 - - 300 20.7 300 20.7 300 20.7 Anvil Class 150/300 Malleable Iron Fittings conform to ASME 616.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES %' (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) [)7T4i!I www.anvilintl.com 17J "U .c j -a I— c C - a) mc 0 I— I Li c®us LISTED <> APPROVED C;] 4 NFPA LJ •IkVA1JA - .-.- - Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. • www.BullMooseTube.com ICHE sales@bullmoosetube.com 800.325.4467 4 THREAD •• S •1 BULL MOOSE TUBE COMPANY c®us LISTED <> APPROVED no ALI NFPR ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM A135 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. EddyLhead 40w: Light threadable Schedule 40 replaceIIIf!!t with corrosion resistance iatio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED <> APPROVED I] NFSA NFPN ri NOMINAL PIPE O.D. SIZE (IN) I.D. (IN) (IN) WATER FILLED BUNDLE CRR** WEIGHT/FT WEIGHT SIZE 1.315 1 097 - 1527 - 11 1.4 1 lbs/ft 1.820 91 1 i114 J[— 9T91 1iiS1ftj12.518 ][ 61 1 11/2i L 1-900 iiii !JlA 61 [ 2 1[ 2375 ][ 2.157iL 627 JL2 64 Ibs/ff] 223 IL 37 j lfl 75 1r 492 [ -3.5 3 Ib7ft 93 fl TL 3500 L3260 ][ - 3_.54= 1 4341 ff11 7957 II - 19 1 TII - ' 4.566 - 4260 [ 250 562I6s/ft - 11796 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1315 1049 j 100 j168(ft 2o55 - IL zc r 1-1/4 11 1.660 ][ i380 II 1.00 I[2.27 ibVfTh 2918 J( 51 100h 272 Ib7ft 3602 r 2 1( 2375 1 207 11 100 j[36617ff1j 51f4 11 30 21/2 I28ThL 60 11 ,J1 3068 IL 1 00 ![7 5iLfF1, 10783 1[ 19 4.500 4.026 LiO 11080IbS/ft 16316'r19 *Oflly available in Casa Grande, AZ **corrosion Resistance Ratio per latest UI Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com C~31 , D Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 01 I 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, 1)( Masury, OH BULL. MOOSE TUBE CONIPANV 63017 FfreLock® Outlet-I ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-I provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11% through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vlclAuuc is A REGISTERED TRADEMARK OF VICTAULIC COMPANY, © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G \4taulacr 10.52 1 Nominal Size mche~,mrn Hole Diameter Dimensions Iiinches/millimeters Approx. Weight _________ 1 Moab _. 1.0 1¼ ½ / 1 o 1.30 1.83 1.10 3.87 2.56 x 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 1/4 1 3/16 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3/16 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 1/2 1 3Ao 1.42 1.95 1.22 4.08 2.56 1.2 x 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1 3A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 1 49.5 31.0 103.6 65.0 0.54 1 1 3A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 584 31.0 103.6 650 0.59 2 1,5 A 1', 1.66 2.19 1.46 4.60 2.56 1.3 x 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3% 1 3A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41,7 55.6 37.1 116.8 65.0 0.64 1 1 3A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 1/2 1 3A6 1.91 2.44 1.71 5.40 2.56 1.6 x 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3% 1 /6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1/16 2.13 2.79 1.71 5,40 2.56 1.6 25 30.2 541 70.9 43.4 137.2 65.0 0.73 ½ 1'A6 1,91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0,73 3% 1 3A6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1'/6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 DIMENSIONS PON PS CARBON STEEL PIPE- HOLE CUT PRODUCTS FiréLock® Outlet-I STYLE 922 'f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vIcTAULIC IS REGISTERED TRADEMARK OF vIcTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 4tauIic REV ( IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS ' '.r4 PERFORMANCE Run Size Inc x Outlet es Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 36) (C=120)*, FT FtImters 1/4 32 25 1 1/2 4. L.1•iiiaa Hazen-Williams coefficient of friction is 120 FireLock® Outlet-T STYLE 922 www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. tau, i c RFV r, 10J12 FirLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com Ii 10.52 3355 REV G UPDATED 1212009 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X.0 A-C —ts 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEELICPVC 1/2 & 3/4 Inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - C&L us 03-EX 2551 1"- 8" LISTED 2 Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-FI-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I WT. 5 WT.+250 UL TEST LOAD 1 3/6 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/6 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 1 2650 8 1/2 1 711.00 1 3805.00 1 4950 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to toss of business or profit, when non-AFCON products have been, or are used. 1/08 S Al .:: . Not less than 1 F! 2" nominal width .. 325nominal Product Features 4l1hI2") - V "No pre-drilling required. ) / ' Not less than "Quick to install using the Sammy Wood Joist 'drill/ddver Nut Driver with an 18V cordless / 1 / of vertical member) - - Saves time from traditional Double Sheetrock c methods. I ' Ceiling "Reduces installation cost 1 • Made in the U.S.A. I 114" 8002957 GST 100 114 x r 210 (7/16" OSB) 670 (3/4" Ply) 25 125 1 #14 Black Nut Driver Part #8113910 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4x3" 2060 (Fir) 25 125 1 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 [" 3/8" 8007957 GST 10 1/4 xl" 210 (7/16" OSB) 300 25 670 (3/4" Ply) 3/8" 8008957 GST 20 1/4x2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 i) 850 25 125 1 3/8" 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 1"'" 3/8" 8010957 GST 30 1/4 2060 (FirL_ 1500 1475 25. 125 I 3/8" 8069925 GST30SS 1/4x3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4x4" 2180 (Fir) 25 125_i 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 - 1/2" 8013925 GST2 1/4x2" 1760 (Fir) 25 125_I #14SWRed 1/2" 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 " I 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 12 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 I 1/2" 8017925 GST6 1/4x6" 2230 25 125 _(F L Nut Driver Part # 8114910 Product Features Eliminates distortion of threaded rod. "Saves time from traditional methods. "Accommodates up to 3 1/2 x 12 pitch roof. Reduces installation cost. "Allows 17° deflection from vertical. Made in the U.S.A. Li 3/8" 8139957 SH-GST 1/4x2" 1257 (F() 1050 1475 25 12° 125 J 3/8" 8141957 SH-GST30 1/4x3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. I 4 I ,'. -... Product Features Not less than T nominal width (1-1/2') up to 3-1/2' pipe; not less than ' "' "' No pre-drilling required. 3' (2-1/2') nominal width 4' & 5' pipe 4 ,1 Floor Joist Quick to install using the Sammy /TT Minimum 2-1/2' from bottom for Nut Driver with an 18V cordless branch lines Minimum 3' from bottom for main lines. Exception: This ". ' drill/driver. requirement shall not apply to 2' or thicker nailing ships resting on top of Saves time from traditional steel beams. methods. Reduces installation cost. Made in the U.S.A. It - - ..1.... .... .. .... - #14 SW Red Nut Driver J 1/4' 8018H SWG 100 1/4x1' 622 (jr),_________ --- ______. 125 1/4" 8019957 SWG 200 1/4 x 2 1725 (Fir) 25 125 8020957 SWG 10 1/4x1"622(Fir) 300 25 125 4 3/8"8021957 SWG 2O 1/4x2_1725(Fir)1050 25 125 3/8' 8073925 SWGS ii4 x 2' 1725JFir) 850 25 125 4 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/5' 8023925 SWG 30 1/4x3' 1884 ()_25 7-2 Part # 8114910 [STALLATIONSTEPSA. INTO WOOD '& STEEL:] STLLO TEPS'"INTO WOOD & STEELj Insert the appropriate nut driver into a 3/8' or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. INOT, WFIN Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. MGM mi-:04161' SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.