HomeMy WebLinkAbout5475 CAR COUNTRY DR; ; AS100153; PermitSprinkler Permit 5475 CAR COUNTRY Job Address: DR Permit Type: SPRINK Parcel No: 2110800900 Lot #: 0 Permit No: AS100153 Status: ISSUED Applied 12/6/2010 Approved: 12/6/2010 Reference No.: Issued: 12/6/2010 PC #: Inspector: Project Title: HOEHN MERCEDES BENZ T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: TATE FIRE PROTECTION SERVICES, INC STEC 13691 DANIELSON ST POWAY, CA Owner: HOEHN GROUP LL C P0 BOX 789 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 AS~c6S~ TATE FIRE I PROTECTION SERVICES INC. DATE: 12/1/10 PROJECT: Hoehn Mercedes Benz 5475 Car Country Drive Carlsbad, CA 92008 JOB NUMBER: S-10-0105 GENERAL CONTRACTOR: White Construction FIRE SPRINKLER HYDRAULIC SUBMITTAL 13691 Danielson Street Suite C - Poway, CA 92064 t. 858-486-0900- F. 858-486-0950 California Cl 6/Cl 0 License # 926322 Carlsbad Municipal Water District Potable Water Discharge Event Report Date: 11j2? 13 Location 5 :t. C2 COljfl2)1 Reason for Discharge Event: Type of Event: initial Dewatering Water Mains ( IA- Estimated Discharge Flow: 1O11G &?M Note: Includes flow testing and flushing - Dewatering Reservoirs ____ Start Time Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. )k End Time Pre-Dechiorination Residual: Post-Dechlorination Residual: 0,057 (less than 0.1 mgiL) pH within limits of 6.0 and 9.0 Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharge water. Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediment or silted areas are cleared. Water Sampling Performed by: CT Comments: Submitted by: Rev,ewd by: (Name & Date) - (Name & Date Flow Test Record Test Hydrant Location Hydrant ID No. Size Main____________ Static............... Residual ......... l,z:) Pressure Drop -1 C5 (PDI 1).....K factor for P1)11.41 Flow Hydrant(s) Hydrant I location Hydrant 2 location Hydrant 3 location Hydrant I Pitot PSI GPM: 100 Size of Orifice 22. Hydrant 2 Pitot PSI GPM: Size of Orifice__________ Hydrant 3 Pitot PSI GPM: Size of Orifice.__________ Total:O1-O (Qi) Calculated test and flow data - 0 x PD2 k =Q2 PDI*k Static: .................... . Desired Residual.......20 Pressure Drop (PD 2). 44 K factor PD 2: 1 040 x —IJ51 by E__41 _equals 3 4_GPM at 20 psi residual QI PD2k POlk Q2 Comments: Test conducted for: Conducted by: C-' / C..1 Date: Time: WATER FLOW TEST REPORT 14 HYDRANT# & LOCATION North and South side of site along Car Country Drive DATE: 11/23/2010 TEST BY: JC & CM Day or Week: Tuesday TIME OF DAY: 8:00 MIN. OF FLOW:2 WATER SUPPLIED BY: Carlsbad Municiple Water District PURPOSE OF TEST: Hoehn Mercedes Benz Remodel DATA FLOW HYDRANT(S) Al A2 A3 SIZE OPENING: 2.5 COEFFICIENT: 0.9 PITOT READING: 38 GPM: 1040 0 0 TOTAL FLOW DURING TEST: 1040 GPM STATIC READING: 65 PSI RESIDUAL: 55 PSI RESULTS: AT 20 PSI RESIDUAL 2341 GPM AT 0 PSI 2858 GPM ESTIMATED CONSUMPTION: 2080 GAL. REMARKS: 100 90 80 70 60 0. U) 1 : 30 20 10 0 0 500 1000 1500 2000 2500 Flow, gpm 13771 Danielson St., Suite G Provided by: Poway, CA 92064 - - - Fire Protection by Computer Design Tate Fire Protection 13771 Danielson Street Suite G Poway, CA. 92064 858-486-0900 Job Name : SI0-0105 Hoehn Design Showroom Building : New Showroom Addition Location : 5475 Car Country Drive System Contract : S-10-0105 Data File S10-0105 Hoehn Hydraulic Calc Showroom.wxf Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Tate Fire Protection Page 1 S10-0105 Hoehn Design Showroom Date 12-1-10 Hydraulic Design Information Sheet Name - Hoehn Design Date - 12-1-10 Location - 5475 Car Country Drive Building - New Showroom Addition System No. - Contractor - White Construction Contract No. - S-10-0105 Calculated By - Lindsey Drawing No. - FP-2 Construction: (x) Combustible ( ) Non-Combustible Ceiling Height - Varies Occupancy - Auto Showroom S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 C ) 2 ( ) 3 C ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C C ) Figure Curve S Other T Specific Ruling Made By Date - a M Area of Sprinkler Operation - 1574 System Type Sprinkler/Nozzle Density - .15 (x) Wet Make TYCO D Area Per Sprinkler - Varies (T) Dry Model TY- FRB ,,/ E Elevation at Highest Outlet - 251211 C ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - C ) Other Temp.Rat.155 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - 275.76 Press Required - 44.39 Summary C-Factor Used: Overhead Underground Water Flow Test: Date of Test - 11/23/10 Time of Test - Static Press - 58.5 Residual Press - 49.5 Flow - 1040 Elevation - Pump Data: Tank or Reservoir: Cap. - Rated Cap.- Elev.- @ Press - Elev. - Well Proof Flow W A T E R S U P P L Y Location - North and South side of site along Car Country Drive Source of Information - Tate Fire Protection C Commodity •Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled Palletized Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage C Encap. S R ( ) Double Row C ) Slave Pallet ( ) Solid Shelf C ) Non T A C ) Mult. Row C ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) Tate Fire Protection Page 2 S10-0105 Hoehn Design Showroom Date 12-1-10 City Water Supply: Cl - Static Pressure : 58.5 C2 - Residual Pressure: 49.5 C2 - Residual Flow : 1040 Demand: Dl - Elevation : 9.961 D2 - System Flow : 275.758 D2-System Pressure : 55.610 Hose (Adj City) Hose ( Demand) : 250 D3 - System Demand : 525.758 Safety Margin : 0.342 150 140 130 P 120 R 110 E 100 90 S 80 U 70 Cl R 60 C2 E 50 D3 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N" 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Tate Fire Protection Page 3 S10-0105 Hoehn Design Showroom Date 12-1-10 Fitting Legend Abbrev. Name ½ % 1 11/4 11/2 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Ziu Wilkins 975 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Pressure I Flow Summary - STANDARD Tate Fire Protection Page 4 S10-0105 Hoehn Design Showroom Date 12-1-10 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. P1 23.0 5.6 10.08 na 17.78 0.15 110 7.0 P2 24.42 10.63 na P3 23.0 5.6 10.33 na 18.0 0.15 120 7.0 P4 24.42 10.9 na P5 23.0 5.6 10.8 na 18.41 0.15 120 7.0 P6 24.42 11.42 na P7 23.0 5.6 11.8 na 19.23 0.15 123 7.0 P8 24.42 12.52 na P9 24.42 14.36 na RNI 24.72 14.82 na Ml 23.5 16.22 na M2 23.5 16.23 na M3 23.5 16.27 na M4 23.5 16.34 na M5 25.0 16.83 na El 25.0 18.81 na E2 25.0 23.94 na E3 25.0 26.6 na 1ST 9.79 34.55 na FEED 11.5 38.2 na TOR 11.5 38.29 na BOR 0.0 44.39 na UGl -3.0 45.69 na BF1 -3.0 45.75 na BF2 -3.0 56.87 na TEST 0.0 55.61 na 250.0 P10 23.0 5.6 7.28 na 15.11 0.15 93 7.0 P11 24.79 7.38 na P12 23.0 5.6 7.46 na 15.29 0.15 101 7.0 P13 24.79 7.59 na P14 23.0 5.6 8.19 na 16.02 0.15 101 7.0 P15 24.79 8.4 na P16 23.0 5.6 9.74 na 17.48 0.15 103 7.0 P17 24.79 10.12 na RN2 24.79 12.55 na P18 23.0 5.6 7.24 na 15.06 0.15 93 7.0 P19 25.17 7.2 na P20 23.0 5.6 7.42 na 15.25 0.15 101 7.0 P21 25.17 7.4 na P22 23.0 5.6 8.14 na 15.98 0.15 101 7.0 P23 25.17 8.21 na P24 23.0 5.6 9.68 na 17.43 0.15 103 7.0 P25 25.17 9.93 na RN3 25.17 12.34 na P26 23.0 5.6 10.45 na 18.1 0.15 110 7.0 P27 25.17 10.81 na P28 23.0 5.6 10.7 na 18.32 0.15 120 7.0 P29 25.17 11.09 na P30 23.0 5.6 11.19 na 18.73 0.15 120 7.0 P31 25.17 11.63 na P32 23.0 5.6 12.2 na 19.56 0.15 123 7.0 P33 25.17 12.77 na RN4 25.17 14.67 na E4 25.0 19.11 na The maximum velocity is 13.17 and it occurs in the pipe between nodes P17 and RN2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Tate Fire Protection Page 5 S10-0105 Hoehn Design Showroom Date 12-1-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C', or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P1 17.78 1.08 2E 4.61 2.375 10.083 K Factor =5.60 to 120.0 iT 5.762 10.372 -0.615 P2 17.78 0.0908 0.0 12.747 / 1.158 Vel = 6.23 P2 0.0 1.408 0.0 11.000 Vl' 10.626 to 120.0 0.0 0.0 0.0 P4 17.78 0.0250 0.0 11.000 0.275 Vel = 3.66 0.0 17.78 10.901 KFactor= 5.39 P3 18.00 1.08 2E 4.61 2.375 10.332 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.615 P4 18.0 0.0929 0.0 12.747 1.184 Vel = 6.30 P4 17.78 1.639 0.0 12.040 10.901 to 120.0 0.0 0.0 0.0 P6 35.78 0.0434 0.0 12.040 0.523 Vel = 5.44 0.0 35.78 11.424 K Factor= 10.59 P5 18.41 1.08 2E 4.61 2.375 10.805 K Factor =5.60 to 120.0 iT 5.762 10.372 -0.615 P6 18.41 0.0968 0.0 12.747 1.234 Vel = 6.45 P6 35.78 1.639 0.0 11.710 11.424 to 120.0 0.0 0.0 0.0 P8 54.19 0.0937 0.0 11.710 1.097 Vel = 8.24 0.0 54.19 12.521 KFactor= 15.31 P7 19.23 1.08 2E 4.61 2.375 11.796 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.615 P8 19.23 0.1051 0.0 12.747 1.340 Vel = 6.73 P8 54.19 1.639 iT 8.727 2.500 12.521 to 120.0 0.0 8.727 0.0 P9 73.42 0.1642 0.0 11.227 1.843 Vel= 11.16 P9 0.0 2.104 1E 5.451 6.500 14.364 to 120.0 0.0 5.451 -0.130 RN1 73.42 0.0487 0.0 11.951 0.582 Vel= 6.78 RN1 0.0 2.104 IT 10.902 1.710 14.816 to 120.0 1E 5.451 16.353 0.528 Mi 73.42 0.0487 0.0 18.063 0.880 Vel = 6.78 Ml 0.0 4.31 0.0 1.500 16.224 to 120.0 0.0 0.0 0.0 M2 73.42 0.0013 0.0 1.500 0.002 Vel = 1.61 M2 63.91 4.31 0.0 8.420 16.226 to 120.0 0.0 0.0 0.0 M3 137.33 0.0046 0.0 8.420 0.039 Vel = 3.02 M3 63.72 4.31 0.0 8.000 16.265 to 120.0 0.0 0.0 0.0 M4 201.05 0.0096 0.0 8.000 0.077 Vel = 4.42 M4 74.71 4.31 31 29.268 14.840 16.342 to 120.0 1J 22.299 51.567 -0.650 MS 275.76 0.0171 0.0 66.407 1.138 Vel = 6.06 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Tate Fire Protection Page 6 SI0-0105 Hoehn Design Showroom Date 12-1-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn M5 -142.48 2.703 ii 9.325 36.500 16.830 to 120.0 0.0 9.325 0.0 El 133.28 0.0433 0.0 45.825 1.983 Vel = 7.45 El 0.0 2.703 II 9.325 92.410 18.813 to 120.0 1J 16.786 26.111 0.0 E2 133.28 0.0433 0.0 118.521 5.131 Vel= 7.45 E2 142.48 4.26 21 18.434 107.170 23.944 to 120.0 1J 21.067 39.501 0.0 E3 275.76 0.0181 0.0 146.671 2.659 Vel = 6.21 E3 0.0 4.26 IJ 21.067 35.750 26.603 to 120.0 21 18.434 39.501 6.587 1ST 275.76 0.0181 0.0 75.251 1.365 Vel= 6.21 1ST 0.0 4.26 2J 42.135 162.820 34.555 to 120.0 41 36.868 79.003 -0.741 FEED 275.76 0.0181 0.0 241.823 4.384 Vet = 6.21 FEED 0.0 6.357 0.0 34.860 38.198 to 120.0 0.0 0.0 0.0 TOR 275.76 0.0026 0.0 34.860 0.090 Vet = 2.79 TOR 0.0 6.357 2E 35.205 11.500 38.288 to 120.0 lFsp 0.0 35.205 5.981 * Fixed loss = 1 BOR 275.76 0.0026 0.0 46.705 0.121 Vet = 2.79 BOR 0.0 8.27 0.0 8.630 44.390 to 150.0 0.0 0.0 1.299 UG1 275.76 0.0005 0.0 8.630 0.004 Vet = 1.65 UG1 0.0 8.044 1L 20.411 92.500 45.693 to 150.0 0.0 20.411 0.0 BF1 275.76 0.0005 0.0 112.911 0.061 Vet = 1.74 BF1 0.0 8.27 4L 93.437 10.000 45.754 to 150.0 lZiu 0.0 93.437 11.065 * Fixed loss= 11.065 BF2 275.76 0.0005 0.0 103.437 0.049 Vet = 1.65 BF2 0.0 8.044 1G 6.28 15.060 56.868 to 150.0 iT 54.952 61.231 -1.299 TEST 275.76 0.0005 0.0 76.291 0.041 Vet = 1.74 250.00 Qa = 250.00 525.76 55.610 K Factor= 70.50 P10 15.11 1.08 2E 4.61 2.750 7.276 K Factor= 5.60 to 120.0 1 5.762 10.372 -0.775 P11 15.11 0.0671 0.0 13.122 0.881 Vet= 5.29 P11 0.0 1.408 0.0 11.000 7.382 to 120.0 0.0 0.0 0.0 P13 15.11 0.0185 0.0 11.000 0.203 Vet= 3.11 0.0 15.11 7.585 KFactor= 5.49 P12 15.29 1.08 2E 4.61 2.750 7.459 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.775 P13 15.29 0.0687 0.0 13.122 0.901 Vet = 5.35 P13 15.11 1.408 0.0 12.040 7.585 to 120.0 0.0 0.0 0.0 P15 30.4 0.0674 0.0 12.040 0.811 Vet = 6.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Tate Fire Protection Page 7 S10-0105 Hoehn Design Showroom Date 12-1-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 30.40 8.396 KFactor= 10.49 P14 16.02 1.08 2E 4.61 2.750 8.188 K Factor = 5.60 to 120.0 IT 5.762 10.372 -0.775 P15 16.02 0.0749 0.0 13.122 0.983 Vel = 5.61 P15 30.40 1.408 0.0 11.710 8.396 to 120.0 0.0 0.0 0.0 P17 46.42 0.1474 0.0 11.710 1.726 Vel = 9.57 0.0 46.42 10.122 KFactor= 14.59 P16 17.48 1.08 2E 4.61 2.750 9.742 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.775 P17 17.48 0.0880 0.0 13.122 1.155 Vel = 6.12 P17 46.42 1.408 iT 6.617 2.500 10.122 to 120.0 0.0 6.617 0.0 RN2 63.9 0.2662 0.0 9.117 2.427 Vel = 13.17 RN2 0.0 1.408 iT 6.617 1.790 12.549 to 120.0 1E 3.308 9.925 0.559 M2 63.9 0.2662 0.0 11.715 3.118 VeI= 13.17 0.0 63.90 16.226 K Factor= 15.86 P18 15.06 1.08 2E 4.61 3.125 7.237 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.940 P19 15.06 0.0669 0.0 13.497 0.903 Vel = 5.27 P19 0.0 1.408 0.0 11.000 7.200 to 120.0 0.0 0.0 0.0 P21 15.06 0.0184 0.0 11.000 0.202 VeI= 3.10 0.0 15.06 7.402 K Factor= 5.54 P20 15.25 1.08 2E 4.61 3.125 7.418 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.940 P21 15.25 0.0685 0.0 13.497 0.924 Vel = 5.34 P21 15.07 1.408 0.0 12.040 7.402 to 120.0 0.0 0.0 0.0 P23 30.32 0.0669 0.0 12.040 0.806 Vel = 6.25 0.0 30.32 8.208 K Factor= 10.58 P22 15.98 1.08 2E 4.61 3.125 8.142 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.940 P23 15.98 0.0745 0.0 13.497 1.006 Vel = 5.60 P23 30.32 1.408 0.0 11.710 8.208 to 120.0 0.0 0.0 0.0 P25 46.3 0.1466 0.0 11.710 1.717 Vel= 9.54 0.0 46.30 9.925 K Factor= 14.70 P24 17.43 1.08 2E 4.61 3.125 9.684 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.940 P25 17.43 0.0875 0.0 13.497 1.181 Vel = 6.10 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 final Calculations - Hazen-Williams ' Tate Fire Protection Page 8 S10-0105 Hoehn Design Showroom Date 12-1-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P25 46.29 1.408 iT 6.617 2.500 9.925 to 120.0 0.0 6.617 0.0 RN3 63.72 0.2649 0.0 9.117 2.415 Vel = 13.13 RN3 0.0 1.408 iT 6.617 2.170 12.340 to 120.0 1E 3.308 9.925 0.723 M3 63.72 0.2647 0.0 12.095 3.202 Vel = 13.13 0.0 63.72 16.265 K Factor= 15.80 P26 18.10 1.08 2E 4.61 3.500 10.446 K Factor= 5.60 to 120.0 IT 5.762 10.372 -0.940 P27 18.1 0.0939 0.0 13.872 1.302 Vel = 6.34 P27 0.0 1.408 0.0 11.000 10.808 to 120.0 0.0 0.0 0.0 P29 18.1 0.0258 0.0 11.000 0.284 Vel = 3.73 0.0 - 18.10 11.092 K Factor = 5.43 P28 18.32 1.08 2E 4.61 3.500 10.701 K Factor = 5.60 to 120.0 IT 5.762 10.372 -0.940 P29 18.32 0.0959 0.0 13.872 1.331 Vel = 6.42 P29 18.10 1.639 0.0 12.040 11.092 to 120.0 0.0 0.0 0.0 P31 36.42 0.0449 0.0 12.040 0.541 Vel = 5.54 0.0 36.42 11.633 K Factor = 10.68 P30 18.73 1.08 2E 4.61 3.500 11.185 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.940 P31 18.73 0.1001 0.0 13.872 1.388 Vel = 6.56 P31 36.42 1.639 0.0 11.710 11.633 to 120.0 0.0 0.0 0.0 P33 55.15 0.0967 0.0 11.710 1.132 VeI= 8.39 0.0 55.15 12.765 KFactor= 15.44 P32 19.56 1.08 2E 4.61 3.500 12.202 K Factor = 5.60 to 120.0 iT 5.762 10.372 -0.940 P33 19.56 0.1083 0.0 13.872 1.503 Vel = 6.85 P33 55.15 1.639 1 8.727 2.500 12.765 to 120.0 0.0 8.727 0.0 RN4 74.71 0.1696 0.0 11.227 1.904 Vel = 11.36 RN4 0.0 2.104 1 10.902 2.540 14.669 to 120.0 1E 5.451 16.353 0.723 M4 74.71 0.0503 0.0 18.893 0.950 Vel = 6.89 0.0 74.71 16.342 K Factor = 18.48 M5 142.48 2.635 ii 8.237 32.960 16.830 to 120.0 0.0 8.237 0.0 E4 142.48 0.0554 0.0 41.197 2.284 Vel = 8.38 E4 0.0 2.635 ii 8.237 64.040 19.114 to 120.0 1J 14.827 23.064 0.0 E2 142.48 0.0555 0.0 87.104 4.830 Vel = 8.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Tate Fire Protection Page 9 S10-0105 Hoehn Design Showroom Date 12-1-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 142.48 23.944 K Factor= 29.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TATE FIRE PROTECTION SERVICES INC. C-16 License #926322 13691 Danielson Street, Suite C - Poway, CA 92064 Phone (858) 486-0900 - Fax (858) 486-0950 DATE: 12/1/10 PROJECT: Hoehn Mercedes Benz 5475 Car Country Drive Carlsbad, CA 92008 JOB NUMBER: S-10-0105 GENERAL CONTRACTOR: White Construction FIRE SPRINKLER MODIFICATION MATERIAL SUBMITTAL Page Product 1-4 Sprinkler Piping 5-12 Sprinkler Piping 13-14 Sprinkler Piping 15-18 Sprinkler Piping 19-22 Sprinkler Piping 23-29 Sprinkler 30 Pipe Hangers & Supports 31 Pipe Hangers & Supports 32 Pipe Hangers & Supports 33 Pipe Hangers & Supports 34 Pipe Hangers & Supports 35 Pipe Hangers & Supports 36-37 Pipe Hangers & Supports Description ALLIED Dyna Thread & Dyna Flow Pipe TYCO Ductile Iron Fittings TYCO Mechanical Tee TYCO Grooved Fittings TYCO Grooved Couplings TYCO. TY-FRB Upright & Pendent Sprinkler AFCON 00 1/020 Sway Brace Fitting-Model E AFCON 076 Attachment Fitting Universal Locking AFCON 300 Ring Hanger AFCON 3 10 Ring Restrainer AFCON 410 Sway Brace Fitting AFCON 655 All Thread Rod SAMMY Wood Screw DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preven:ing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-I 35, Grade A and is in compliance with NFPA- 13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21) Wt/1.ift (24) Wtl1Jft (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105 11/4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/2 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 16100 S. Lathrop ' Harvey, IL 60426 tLICO/F/ow Control ) cIIjecJ 11350 Norcom Rd. Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S3 -3 4 SPECIFICATION SUBMITTAL JAL SHEET FEATURES Sizes: 021/2" 03" L14" L36" 08" L3110" Maximum working water pressure 175 psi Maximum working water temperature 1400 F End connections flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with NRS gate valves (standard) U G - with grooved by flanged NRS gate valves U L - less shut-off valves U OSY - with OS & Y gate valves U OSYG - with grooved by flanged OS & Y gate valves U FS - with cast iron "V' type flanged strainer U FSC - with cast iron "V' type flanged strainer, fusion epoxy coated, inside and out U BMS - with integral battery-operated relief valve monitor switch U MS - with integral relief valve monitor switch ACCESSORIES U Repair kit (rubber only) U Air gap (Model AG) U Water thermal expansion tank (Model WXTP) DIMENSIONS & WEIGHTS (do not include pkg.) APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. The Model 975 provides protection where a potential health hazard exists. STANDARDS COMPLIANCE ASSE®Listed 1013 IAPMO® Listed CSA® Certified UL® Classified C-UL® Classified FM® Approved AWWA Compliant C511 Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California MATERIALS Main valve body Cast iron, ASTM A 126 Class B Acess covers Cast iron, ASTM A 126 Class B Coatings Fusion epoxy finish (FDA approved) Internals Stainless steel, 300 Series Cast bronze, ASTM B 584 Elastomers EPDM (FDA approved) Buna nitrile (FDA approved) Polymers Acetal (DelrinTM), NSF® Listed Springs Stainless steel, 300 Series DIMENSIONS (approximate) WEIGHT MODEL B WITHOUT E OS&Y E OS&Y E NRS WITHOUT WITH NRS WITH OS&Y GATE E SIZE A GATE C D GATEVE GATE F G GATE GATE GATE VALVES VALVE. VALVES VALVES VALVES OPEN CLOSED 21/2 65 1 371/8 943 22 559 4 102 10 254 163/8 416 137/8 352 113/8 289 83/8 213 16 406 91 41.3 193 87.6 201 91.3 3 80 381/8 968 22 559 4 102 10 254 187/8 479 155/8 397 12 3/8 314 91/4 235 16 406 91 41.3 215 97.6 221 100.3 4 1001501/4 1276 321/8 816 5 127 10 254 223/4 578 181/4 464 143/4 375 12 1/2 318 22 559 232 105.3 412 187 422 191.6 6 1501621/8 1578 41 1041 6 152 11 279 301/8 765 233/4 603 19 483 14 356 30 762 526 238.8 810 367.7 826 375 8 200171 1/8 1807 48 1219 71/2 191 12 305 373/4 959 291/4 743 22 1/2 572 173/4 451 31 787 837 380 1289 585.2 1313 596 70 2501841/8 2137 58 1473 9 229 14 356 453/4 1162 353/8 899 26 1/2 673 211/4 540 41 104 1400 635.6 2160 980.6 2218 1007 age 1 of 2 U) a. U) U) 0 —j Ui U) U) Ui 20 15 10 PROTECTIVE FLOW CHARACTERISTICS MODEL 975 2 1/2",3" & 4 (STANDARD & METRIC) FLOW RATES (Its) 12.6 25.2 37.9 200 400 600 FLOW RATES (GPM) I 50.5 138 a- U) 104 U) 0 -J 69 35 cc 800 - - BEEIR - iIl,ll MODEL 975 6', 8' & 10'(STANDARD & METRIC) FLOW RATES (us) 63.1 126.2 189.3 252.4 MEMNON -I Ks1ii1Th .. IL 0 1000 2000 3000 4000 FLOW RATES (GPM) TIlP Al lt.IYAl I ArlFtl Local codes shall govern installation requirements. Un- less otherwise specified, the assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Assem- bly shall be installed with adequate drain and sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged or where relief valve discharge could cause damage. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 21/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 TYPICAL OUTDOOR INSTALLATION TYPICAL INDOOR INSTALLATION SPECIFICATIONS The Reduced Pressure Principle Backf low Prevention Assembly shall be ASSE® 1013 Listed and supplied with full port gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM A 126 Class B), the seat and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM (FDA approved). The first and second checks shall be accessible for mainte- nance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral relief valve monitor switch. The Reduced Pressure Principle Backflow Prevention Assembly shall be a WILKINS Model 975. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) 9 Website: http://www.zurn.com Submittal Data Sheet Dyna-Thread® Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NI'S Nominal I.D. WI. WI. (H20 Filled) Pcs/ WI/Lift (21) Wt/Uft (24) Wt1l.ift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1051 11/4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 11/2" 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is (P (~~ manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: S3 -4 Dyna-Flow® High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule- 10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Specif 'fl [I] II. NPS Nominal I.D. Wt. WI. (H20 Filled) Pcs/ WI/Lift (211) WI/Lift (24') WI/Lift (251) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11/2 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2" 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. @ <~> (q~ Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tLICO/Flow Control () allied 16100 S. Lathrop. Harvey, IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S2 -3 Stamp Here American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufac- tured with Black lacquer coating. (IJ L &L Listed Approved Listed Submittal Data Sheet Dyna.Flowo High Strength Steel Pipe Dyna-Flow pipe is the "original" high-strength lightwall sprinkler pipe. Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Light- weight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. Additional Benefits Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. Superior Hydraulics With an inside diameter of up to 11% larger than Schedule 40 and up to 7% larger than SchedulelO, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna- Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Coatings & Fabrication Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or, water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment is needed for fabrication and installation. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications & Approvals Dyna-Flow/Super 40 pipe is manufactured to meet ASTM A 795 Type E, Grade A and are in compliance with NFPA-I 3 and NFPA-14. All sizes of Dyna Flow are UL Listed, FM Approved and ULC Listed. Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, thy, pre-action and deluge systems. It is FM Approved for roll grooved, plain-ended, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna-Flow/Super Flo is now available "hot-dip" galvanized and has been spe- cifically approved by FM for thy systems uses. Speci fications NPS Nominal I.D. Wt. WI. (H20 Filled) Pcsl WI/Lift (21') Wtllift (24) WI/Lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg V 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11/2" 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2" 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2" 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Tate Fire Protection Project: Sprinkler Contractor Date: Engineer: Specification Reference: System Type: Locations: Comments: S2 -4 tqCLY /Fire & Building / )Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco® Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Material: Series 800 and California Fittings Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or ar.y other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. registered trademark of E. I. du Pont de Nemours and Company or its affiliates. TFPI7IO Page 1 of 10 JANUARY, 2008 Page 2of 10 TFPI7I0 _ A FIGURE 811 FIGURE 813 9Q0 ELBOW 450 ELBOW Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) TABLE 1 NOMINAL DIMENSIONS FIGURES 811 & 813 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 DN25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DNSO (57,1) (0,70) 2-1/2 2.69 2.70 86782 DN65 (68,3) (1,22) 0 TFPI7IO Page 3 of 10 FIGURE 812 90° REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Inches Inches Inches Inches Inches Weight Lbs. Part DN (mm) (mm) (mm) (mm) Number (kg) 3/4 x 1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20x 15 (302) (30,2) (16,0) (16,0) (0,15) I x 1/2 1.25 1.38 0.56 0.81 0.44 86210 DN25x15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-1/4x 1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4 x 3/4 1.44 1.63 0.75 1.06 0.75 DN32x20 (36,6) (41,4) (19,0) (26,9) (0,34) 86213 1-1/4 x 1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40x20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2x1 1.63 1.81 0.88 1.13 0.99 86215 DN40x25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-1/2x1-1/4 1.81 1.88 1.13 1.19 1.14 DN40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 86216 2 x 3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22,4) (35,1) (0,63) 2 x 1 1.75 2.06 2.00 1.31 1.58 86218 DN50 x 25 (44,4) (52,3) (50,8) (33,3) (0172) 2x1-1/2 2.00 2.19 1.25 1.44 1.67 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 86220 2-1/2x2 2.38 2.63 1.25 1.88 3.01 86262 DN65 x 50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 (D TFPI7IO Page 5 of 10 FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING Nominal Pipe Figure 814 Figure 818 Size A B Approx. A B Approx. ANSI Inches Inches Inches Weight Part Inches Inches Weight Part DN (mm) (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) 1/2 1.13 0.56 0.33 86340 1.38 0.31 0.18 72779 DN15 (28,7) (14,2) (0115) (35,1) (7,9) (0,08) 3/4 1.31 0.75 0.50 86341 1.63 0.56 0.26 72778 DN20 (33,3) (19,0) (0,23) (41,4) (14,0) (0,11) 1 1.50 0.81 0.85 86230 1.75 0.38 0.44 72755 DN25 (38,1) (20,6) (0,38) (44,4) (9,7) (0,20) 1-1/4 1.75 1.06 1.30 86231 2.00 0.56 0.54 72754 DN32 (44,4) (26,9) (0,59) (50,8) (14,0) (0,24) 1-1/2 1.94 1.19 1.63 86232 2.19 0.75 0.71 72753 DN40 (49,3) (30,2) (0,74) (55,6) (19,0) (0,32) 2 2.25 1.50 2.63 86233 2.63 1.13 1.15 72752 DN50 (57,1) (38,1) (1,19) (66,8) (28,7) (0,52) 2-1/2 2.69 1.56 4.55 86234 3.00 0.75 2.29 72758 0N65 (68,3) (39,6) (2,06) (76,2) (19,0) (1,04) TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 TFPI7I0 Page 60f 10 Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C D E F Approx. ANSI Inches Weight Part DN Inches Inches Inches Inches Inches Inches (mm) (mm) (mm) (mm) (mm) (mm) Lbs. Number (kg) 1-1/2 x 1-1/4 x 1/2 1.44 1.31 1.69 0.69 0.63 1.13 1. DN40 x 32 x 15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,7) (0 147) 8625703 1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 DN40x32x20 (38,1) (36,6) (44,5) (19,0) (19,0) (30,1) (0,50) 86258 1-1/2 x 1-1/4 x 1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 DN40x32x25 (41,4) (39,7) (46,0) (22,4) (22,4) (28,7) (0,59) 86259 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 DN40x32x50 (55,6) (54,1) (50,8) (36,6) (36,6) (57,1) (0,88) 86260 1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 DN40 x 40 x 15 (36,6) (36,6) (42,9) (17,5) (17,5) (28,7) (0,52) 86261 1-1/2 x 1-1/2 x 3/4 1.50 1.50 1.75 0.75 0.75 1.19 1.23 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19,0) (30,1) (0,56) 86262 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 DN40x40x25 (41,2) (41,2) (46,0) (22,4) (22,4) (28.7) (0,62) 86263 1-1/2 x 1-1/2 x 1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68) 86264 1-1/2 x 1-1/2 x 2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 DN40x40x50 (55,5) (55,5) (50,8) (36,6) (36,6) (31,7) (0,91) 86265 2 x 1 x 2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 DN50x25x50 (57,2) (50,8) (57,2) (38,1) (33,3) (38 (0,99) 86266,1) 2 x 1-1/4 x 2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 DNSO x 32 x 50 (57,2) (54,1) (57,2) (38,1) (36,6) (38,1) (1,05) 86267 2 x 1-1/2 x 1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 DN50 x 40 x 15 (38,1) (36,6) (47,8) (19,0) (17,5) (33,3) (0,68) 86268 2 x 1-1/2 x 3/4 1.63 1.50 1.94 0.88 0.75 1.38 1.61 DNSO x 40 x 20 (41,4) (38,1) (49,3) (22,4) (19,0) (35,0) (0,73) 86269 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 DN50x40x25 (44,5) (41,4) (50,8) (25,4) (22,4) (33,3) (0,75) 86270 2x1-112x1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 DN50x40x40 (52,4) (49,2) (55,5) (33,3) (30,2) (36,6) (0,92) 86272 2 x 1-1/2 x 2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 DN50x40x50 (57,1) (55,5) (63,5) (38,1) (36,6) (38,1) (1,07) 86273 2x2x1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 DN50x50x15 (38,1) (38,1) (47,8) (19,0) (19,0) (33,3) '(0,68) 86222 2x2x3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 DN50x50x20 (41,4) (41,4) (49,3) (22,4) (22,4) (35,0) (0,76) 86223 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 DNSO x 50 x 25 (44,5) (44,5) (50,8) (25,4) (25,4) (33,3) (0,86) 86224 2x2x1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2.05 DN50x50x32 (47,8) (47,8) (54,1) (28,7) (28,7) (36,6) (0.93) 86225 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 DN50x50x40 (50,8) (50,8) (55,6) (31,8) (31,8) (38,1) (0,96) 86226 2x2x2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3.67 DN50x50x65 (66,8) (66,8) (60,5) (44,5) (47.8) (36,6) (1,66) 86227 2-1/2x2x3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 DN65x50x20 (44,5) (41,4) (58,7) 1 (15,9) (22,4) 1 (44,5) (1,01) 86274 TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO Err!,%-.H0jwM FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) __ (kg) (kg) 1/2 0.88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) __ (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0,10) __ (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0 ,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 DN32 (33,3) (0,24) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 DN50 (38,1) (0,43) (79,5) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) ________ ________ ________ ________ ________ ________ TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 (B TFPI7IO Page 9 of 10 FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - DN15x15 (381) (0,09) 1/2x1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0,10) 3/4x3/4 2.00 0.31 73982 - - - - - - - DN20 x 20 (50,8) (0,14) 3/4x 1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - - - (43,2) (17,5) (0,17) 1 x 1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25x 15 - - - (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25 x 20 - - - (26,9) (0,08) (43,2) (12,7) (0,24) 1-1/4x1 1.19 0.31 DN32 x 25 - - - (30,2) (0,14) 1-1/2x1 1.25 0.53 DN40x25 - - - (31,7) (0,24) 1-1/2x1-1/4 1.25 0.35 72764 - - - - DN40x32 - - - (31,7) (0,10) 2x1 S 1.38 0.75 72759 - - - - DNSO x 25 - - - (35,1) (0,34) 2 x 1-1/4 1.38 0.69 72761 - - - - DN50x32 - - (35,1) (0,31) 2x1-1/2 1.38 0.62 72775 - - - - DN50x40 - - - (35,1) (0,28) TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 (D General Description istirigiipprovai intormation tqC0 /Fire & Building I Products Technical Services: Tel: (800) 381-9312! Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap The Figure 40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las with the app/ica blestandards of the National Fire Protection Association, in addition to the standards of any otherauthorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershouldbe contacted With any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade E" EPDM green color code. (See Data Sheet 1FP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownershipwith Tyco Fire Products orfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and!orthe standards of any otherAuthonties Having Jurisdiction. MateaIs found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumefor it, any otherobligation in connection with the sale of products or parts of products. Tyco Fire Productsshall notbe responsibIeforspnklersystem design errors or inaccurate orincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCO FIRE PRODUCTSWAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRE&S OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 0 TFPI72O Page 1 of 2 September 2004 Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11/4 X 1/2" 2.00 1.50 3.50 1.20 1/16 0.84 50.8 38.1 88.9 30.5 30.2 0.4 11/4"x3/4' 2.00 1.50 3.50 1.20 1/i6 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/4 2.31 1.68 3.50 1.20 1/16 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/2 X /2,1 2.12 1.62 3.50 1.32 13A6 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/2' x 3/4" 2.12 1.62 3.50 1.32 13A6 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/2 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2" x /2" 2.36 1.86 3.74 1.55 13A6 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2'x3/4' 2.36 1.86 3.74 1.55 13A6 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2" x 1 2.67 2.04 3.74 1.55 13A6 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2 X 1/2 2.61 2.11 4.25 1.80 13A6 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2 X3/4" 2.61 2.11 4.25 1.80 1/16 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2" x 1" 2.92 2.29 4.25 1.80 13A6 1.21 74.2 58.2 1 108.0 1 45.7 1 30.2 1 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 1h/4 x 1' 8 11/2" x 1" 6 2'x 1° 1 6 21/2' x 1" 1 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP 1720 Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. (:14) General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tqC0 Fire & Building IProducts Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description 1 1 See Fire Protection [LBJ VdSJ Submittal Sheet for Pressure Rating and Listing/Approval UL (Information . The grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile iron or fabricated steel as indicated. Note: Figure 510S and 519S fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there maybe interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 510S and 519S fittings. Contact Tyco Fire Products for details. WARNING The Fittings described herein must be installed andmaintainedin compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershouldbe contacted with any questions. Technical Data Approvals: UL, FM, ULC, VdS, and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing / Approval information. Material: Cast: Figures: 201,210,219, 250,260,501,510, 519,51ODE, 501S, 510S and 519S - Ductile iron conforming to ASTM A-536, Grade 65-45-12 Fabricated Steel: Figures 391, 392, 393, 312, 313, 321, 327, 341 and 350 - Carbon Steel, (Sizes 11/4 - 6' are Schedule 40); (Sizes 8"- 12" are Schedule 30), conforming to ASTM A-53 Grade B Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicabe standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractoror product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Productsorfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthe standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Productsshall not beresponsibleforspdnklersystem design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCOFIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTiES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 6 September 2004 TFPIBIO Figure 210 EtoE1 - Figure 260 Figure 219 Friction Resistance* (Expressed as Equivalent Straight Pipe) Elbow Tee Size 90° 45° Branch Run Feet Feet Feet Feet Inches MM Meters Meters Meters Meters 1 '/4 1.9 1.0 4.8 1.9 42.4 0.6 0.3 1.5 0.6 11/2 2.3 1.2 5.8 2.3 48.3 0.7 0.4 1.8 0.7 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1.0 21/2 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 4.1 2.1 10.3 4.1 76.1 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 6.5 3.3 16.3 6.5 108.0 2.0 1.0 5.0 2.0 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 8.0 4.0 20.0 8.0 133.0mm 2.4 1.2 6.1 2.4 139.7mm 8.0 TT 20.0 8.0 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 2.5 9.5 4.8 23.8 9.5 159.0mm 2.9 1.4 7.2 2.9 9.5 4.8 23.8 9.5 165.1mm 2.9 1.4 7.2 2.9 6 9.9 • 24.8 9.9 168.3 3.0 1.5 7.6 3.0 13.1 -- 32.8 13.1 216.3mm 4.0 2.0 10.0 4.0 8 13.1 32.8 13.1 219.1 4.0 2.0 10.0 4.0 10 16.5 41.3 16.5 273.0 5.0 2.5 12.6 5.0 12 19.9 9.9 49.7 19.9 323.4 6.1 3.0 15.1 6.1 Figure 201 Figure 210 Figure 219 HgurebU; 45° Elbow 90° Elbow Tee EndCap Nominal C to E Appx. Wt. CtoE Appx. Wt. C to E Appx. Wt. E to E Appx. Wt Size Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. mm Kg. 11/4 1.75 0.9 1.0 2.75 1.4 0.88 0.4 44.5 0.4 69.9 0.5 69.9 0.6 22.4 0.2 11/2* 1.75 1.1 T7 1.2 2.75 1.8 0.6 44.5 0.5 1 69.9 0.5 1 69.9 0.8 22.4 0.3 2' 2.00 1.8 2.0 3.25 2.7 0.9 50.8 0.8 82.6 0.9 82.6 1.2 22.4 0.4 21/2 2.25 2.2 3.0 3.75 5.8 0.9 57.2 1.0 95.3 1.4 95.3 2.6 22.4 0.4 76.1 mm 2.25 2.2 3.0 3.75 5.8 0.94 1.1 57.2 1.0 95.3 1.4 95.3 2.6 23.9 0.5 2.50 3.5 4.25 4.5 4.25 7.0 0.88 1.1 63.5 1.6 108.0 2.0 1 108.0 3.2 22.4 0.5 108.0mm 2.88 5.5 4.75 8.5 4.75 11.5 73.0 2.5 120.7 3.9 120.7 5.2 - 3.00 5.2 5.00 8.5 5.00 11.8 1.00 2.6 76.2 2.4 127.0 3.9 127.0 5.4 25.4 1.2 133.0mm 3.25 7.7 5.25 11.3 5.25 10.6 - 82.6 3.5 133.4 5.1 133.4 4.8 - - 139.7mm 3.25 7.7 - 5.50 11.3 5.50 15.3 0.92 4.7 82.6 3.5 139.7 5.1 1 139.7 6.9 23.4 1 2.1 3.25 8.5 5.50 13.5 5.50 17.0 1.00 5.0 82.6 3.9 139.7 6.1 139.7 7.7 25.4 2.3 159.0mm 3.50 12.0 6.00 14.6 6.00 13.9 - 88.9 5.4 152.4 6.6 152.4 6.3 - - 165.1mm 3.50 12.0 6.50 18.5 . 6.50 26.0 1.00 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 6° 3.50 12.0 6.50 18.5 6.50 26.0 1.00 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 216.3mm 4.25 23.0 7.75 36.5 7.75 45.0 - 108.0 10.4 196.9 16.6 196.9 20.4 - - 8° 4.25 23.0 7.75 36.5 7.75 45.0 Ti 12.8 108.0 10.4 196.9 16.6 196.9 20.4 30.2 5.8 4.75 31.0 9.00 60.0 9.00 72.1 1.25 20.0 10.1 120.7 14.1 228.6 27.2 228.6 32.7 31.8 9.1 12' 5.25 1 40.0 1 10.00 1 67.0 10.00 92.5 1.25 36.0 133.4 18.1 254.0 30.4 254.0 42.0 1.L&. 16.3 -Available with tapped plugs, contact Tyco Fire & Building Products. C to?\ C to .,.. Figure 201 -CtoE - - Page 2 of 6 TFP 1810 Figures 201, 2109 219, and 260 For reducing tees and branches, use the value that is corroaponding to the branch size. Example: for 8" a 8" a 2" tee, the branch value 2' is 8.0 feet. * Friction resistance for all elbows and tees except Figures 510S and 519S. 8 Figure 501S Friction Resistance 501S, 510S & 519S (Expressed as Equivalent Straight Pipe) Elbow Tee 900 45° Branch Run Size Feet Feet Feet Feet Inches MM Meters Meters Meters Meters 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1.0 21/2 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 4.1 2.1 10.3 4.1 76 1 °° 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 8.0 4.1 20.0 8.0 1397 °°° 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 2.5 uu..,.umm 9.5 4.8 23.8 9.5 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 7.6 3.0 8 13.1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 Page 3of 6 TFP1810 Figures 501, 510, 519 and 51 ODE T, L 101 r4 ;- G to E 1--A~- :cto E Figure 501 Figure 510 Figure 519 Figure 51 ODE Figure 501 Figure 510 Figure 519 Figure 51ODE 45° Elbow 90° Elbow Tee 90° Drain Elbow Nominal C to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. C to E A B Appx. Wt. Size Inches Lbs. Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. mm Kg. mm Kg. mm Kg. mm mm mm Kg. 1 1 /4 1.75 0.9 2.75 1.0 2.75 1.4 44.5 0.4 69.9 0.5 69.9 0.6 - - - - V /2" 1.75 1.1 2.75 1.2 2.75 1.8 44.5 0.5 69.9 0.5 69.9 0.8 - - - - 2 2.00 1.8 3.25 2.0 3.25 2.7 50.8 0.8 82.6 0.9 82.6 1.2 - - 21/2" 2.25 2.2 3.75 3.0 3.75 5.8 3.75 2.00 2.75 2.7 57.2 1.0 95.3 1.4 95.3 2.6 95.3 50.8 69.9 1.2 2.50 3.5 4.25 4.5 4.25 7.0 4.25 2.34 2.75 3.7 63.5 1.6 108.0 2.0 108.0 3.2 108.0 59.4 69.9 1.7 3.00 5.2 5.00 8.5 5.00 11.8 5.00 2.85 2.75 7.0 76.2 2.4 127.0 3.9 127.0 5.4 127.0 72.4 69.9 3.2 3.25 8.5 5.50 13.5 5.50 17.0 5.50 3.38 2.75 13.0 82.6 3.9 139.7 6.1 139.7 7.7 139.7 85.9 69.9 5.9 6 3.50 12.0 6.50 18.5 6.50 26.0 6.50 3.92 2.75 13.4 88.9 5.4 165.1 8.4 165.1 11.8 165.1 99.6 69.9 6.1 8° L 4.25 23.0 7.75 36.5 7.75 45.0 7.75 4.95 2.75 26.3 ______ 108.0 10.4 196.9 16.6 196.9 20.4 196.9 125.7 69.9 11.9 Figures 501S, 510S and 519S Cto E c ' to E Figure 510S° Figure 519S° Figure 501S Figure 510S Figure 519S 45° Elbow 90° Elbow Tee Nominal C to E Appx Wt. C to E Appx. Wt. C to E Appx. Wt. Size Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. 2 2.00 1.8 2.75 1.5 2.75 2.1 50.8 0.8 69.9 0.7 69.9 1.0 2/2 2.25 2.2 3.00 2.2 3.00 3.0 57.2 1.0 76.2 1.0 76.2 1.4 76.1mm 2.25 2.2 3.00 2.3 3.00 3.1 57.2 1.0 76.2 1.0 76.2 1.4 2.50 3.5 3.38 3.0 3.38 4.1 63.5 1.6 85.9 1.3 85.9 1.9 3.00 5.2 4.00 5.6 4.00 7.7 76.2 2.4 101.6 2.6 101.6 3.5 139.7mm 3.25 7.7 4.88 8.6 4.88 12.0 82.6 3.5 124.0 3.9 124.0 5.4 3.25 8.5 4.88 8.8 4.88 12.0 82.6 3.9 124.0 3.9 124.0 5.4 165.1mm 3.50 12.0 5.50 11.00 5.50 15.0 88.9 5.4 139.7 5.0 139.7 6.8 6 3.50 12.0 5.50 11.2 5.50 15.2 88.9 5.4 139.7 5.1 139.7 6.9 8 4.25 23.0 6.88 23.4 6.88 31.2 108.0 10.4 174.8 10.6 174.8 14.2 Note. Figure 510S and 519S fillings are special short radius fittings with smauer center tn end dimensi than standard grooved fittings. Depending on the size and coupling used, there may be Interfere ce at the hell pads which requires repositioning 01 the coupling orientation. The use of flange adapt rs is net recommended with Figures 510S and 519S fittings. Contact Tyco Fire Products for details. Page 4of6 TFP1810 Figures 250 and 350 h-F toE-1 Figure 250 Cast h-EtoE1 Figure 350 Fabricated Sizes 3" to 6" h-Et0 F-1 Figure 350 Fabricated Sizes 8" to 12" Note: Sizes marked with an asterisk () are only available in Figure 250 Cast. Sizes without an asterisk are only available in Figure 350 Fabricated. ADA CAP® Patented Figures 250 and 350 Concentric Reducer - Groove x Groove Nominal E to E Appx. Wt. Nominal E to E Appx. WI. Nominal E to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. Inches mm Kg. 2.50 1.0 3.50 4.2 4.00 5.8 *2 X 1¼ 63.5 0.5 *139.7mm X 88.9 1.9 *6 X 101.6 2.6 2.50 1.3 3.50 4.4 5.00 12.2 *2x U/2 63.5 0.6 *1397x4 88.9 2.0 8x2 127.0 5.5 2.50 1.2 3.50 4.6 5.00 12.1 *2½x2 63.5 0.5 5X11/2 88.9 2.1 8x2½ 127.0 5.5 2.50 1.5 3.50 4.6 5.00 12.0 mm *761 x 1½ 63.5 0.7 5 x 2 88.9 2.1 8 x 127.0 5.5 2.50 1.6 3.50 4.5 5.00 11.9 M. *761 x 2 63.5 0.8 5 x 2V 88.9 2.0 8 x 127.0 5.4 2.50 1.3 3.50 4.4 5.00 11.3 3x1¼ 63.5 0.6 5x3 88.9 2.0 8x5 127.0 5.1 2.50 1.3 3.50 4.5 5.00 10.8 3 x 1½ 63.5 0.6 *5 x ' 88.9 2.0 8 x 6 127.0 4.9 2.50 1.3 4.00 5.5 6.00 21.9 *3 x 2 63.5 0.6 *1651 x 101.6 2.5 lOx 4 152.4 10.0 *3 x 2½ 3.00 76.2 1.5 0.7 *165.1mm X 4.00 101.6 6.0 2.7 lOx 5 6.00 152.4 21.6 9.8 3.00 2.0 4.00 5.6 6.00 21.1 mm *3 x 761 76.2 0.9 165.lm*X139.7*m 101.6 2.5 10x6 152.4 9.6 3.00 2.2 4.00 6.0 6.00 19.5 4x 1¼ 76.2 1.0 *6 x 2 101.6 2.7 10x8 152.4 8.9 3.00 2.3 4.00 6.0 7.00 28.0 4x1½ 76.2 1.0 6 x 2½ 101.6 2.7 12x4 177.8 12.7 3.00 2.3 4.00 6.0 7.00 30.0 *4 X 2 76.2 1.0 *6 X 76.1 mm 101.6 2.7 12 x 6 177.8 13.6 3.00 2.3 4.00 6.0 7.00 28.0 *4 x 2½ 76.2 1.0 6x3 101.6 2.7 12 x 8 177.8 12.7 3.00 3.2 4.00 5.9 7.00 33.0 *4 x 76.1 mm 76.2 1.5 *6 X 101.6 2.7 12 X 10 177.8 15.0 3.00 2.6 4.00 6.3 x 76.2 1.2 *6 X 139.7mm 101.6 2.9 Pi )e Nominal Dimensions Net O.D. Takeout Center to End Size Outlet Wt. A B C D Inches NPT* Inches Inches Inches Inches Lbs. Inches mm mm mm mm Kg. 1/2 1.25 1.75 1.89 0.77 31.8 44.5 48.0 0.3 1.25 1.75 1.89 0.77 lh/2 1.900 48.3 31.8 44.5 48.0 0.3 1 1.37 2.00 2.02 0.88 34.8 50.8 51.3 0.4 1/s 1.25 1.75 1.89 0.92 31.8 44.5 48.0 0.4 3/4 1.25 1.75 1.89 0.92 2 2.375 60.3 31.8 44.5 48.0 0.4 1 1.37 2.00 2.02 1.06 34.8 50.8 51.3 0.5 1/2 1.47 1.97 1.89 1.28 37.3 50.0 48.0 0.6 1.47 1.97 1.89 1.28 14 73.0 37.3 50.0 21/2 E 2.875 48.0.6 1.37 2.00 1. 2.02 34.8 50.8 51.3 0.7 F L * 50-7 threaded outlets are available upon request. tqCo Fire & Building IlProducts Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 705 Flexible Coupling General Description Listing/Approval Intormation The Figure 705 Flexible Coupling is capable of pressures up to 300 psig (2068 kPa) depending on pipe size and wall thickness when used in fire protection services. It provides a dependable method of joining pipe and is suitable for use in a variety of applications. Rigid Couplings are recommended for dry pipe and freezer applications. WARNING The Figure 705 flexible Coupling described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities ha ving jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Figure: 705 Sizes: 11/4" - 12' Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing! Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) Grade 'A" EPDMA violet color code ambientto +150°F(+66°C)forfire protection systems. Not recommended for hot water systems. Tr-seal (Grade "E" EPDM), green color code. Prelubricated (Grade A" EPDMA) (See Data Sheet 1FP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) or Grade "E" EPDM Tr-Seal, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Productsorfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and!orthe standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit, any other obligation in connection with the sale of products or parts of products. Tyco Fire Productsshall notbe responsible for spnklersystem design errors or inaccurate orincomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCO FIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRAVT1ES EXPRESS OR IMPLIED, INCLUDING WARRANTIES MERCHANTABILITY AND FITNESS FO PARTICULAR PURPOSE. Page 1 of 2 July 2004 TFP1826 Page 2of 2 TFP1820 Figure 705 Grooved Coupling Pipe Max. °f End Gap Max.t Pressure Max.t End load Nominal Dimensions Deflection ° Bolt Net Wt. 0. D. A B C Inches! Size Inches Inches psi Lbs. Inches Inches Inches 'Per Foot Size** Lbs. mm mm kPa N mm mm mm Coupling mm/rn Dia. x Lg. Kg. 1.660 0.13 300 649 2.56 4.19 1.81 0.90 /8 x 21/4 1.5 1 1 42.4 3.3 2,068 2,887 65.0 106.4 46.0 - 4° 19' 75.0 M10 x 57 0.7 1.900 0.13 300 850 2.75 4.44 1.81 0.79 !8° x 21/4"T 1 1 /2 48.3 3.3 2,068 3,781 69.9 112.8 46.0 30 - 46' 65.8 M10 x 57 0.7 2.375 0.13 300 1,328 3.25 4.88 1.88 0.63 3!8"X2V4" 1.7 2 60.3 3.3 2,068 5,907 82.6 124.0 47.8 30 1 - 52.5 M10x57 0.8 2.875 0.13 300 1,947 3.69 5.50 1.88 0.52 !" x 2V4" 2.0 1 2/2 73.0 3.3 2,068 8,660 93.7 139.7 47.8 - 2° 29 43.3 Mb x 57 0.9 3.000 0.13 300 2,120 4.00 5.75 1.88 0.50 3.1 76.1 mm 76.1 3.3 2,068 9,430 101.6 146.1 47.8 2• -23 41.7 M12x76 1.4 3.500 0.13 300 2,885 4.38 6.50 1.88 2° 3 0.43 1!2' x 3' 3.0 88.9 3.3 2,068 12,832 111.3 165.1 47.8 - 35.8 M12x76 1.4 4.250 0.25 300 4,256 5.50 7.50 2.06 0 0.70 4.2 108.0mm 108.0 6.4 2,068 18,931 139.7 190.5 52.3 3 -22 58.3 M12x76 1.9 4.500 0.25 300 4,769 5.69 7.75 2.06 30 11' 0.67 1/211 x 3' 4.0 114.3 6.4 '2,068 21,213 144.5 196.9 52.3 - 55.8 M12x76 1.8 5.250 0.25 300 6,494 6.56 9.50 2.06 0.56 7.2 133.0mm 0 2 -44 M16x83 133.0 6.4 2,068 28,885 166.6 241.3 52.3 46.7 139.7mm 5.500 0.25 300 7,127 6.81 9.75 2.06 , 2 -36 0.56 7.2 139.7 6.4 2,068 31,701 173.0 247.7 52.3 46.7 M16 x 83 3.3 5.563 0.25 300 7,288 6.88 9.75 2.06 2° 35 0.54 5 !8' x 31/4' 7.0 141.3 6.4 2,068 32,417 174.8 247.7 52.3 - 45.0 M16x83 3.2 6.250 0.25 300 9,204 7.56 10.31 2.06 0.48 7.4 159.0mm 2' -17, M16 x 83 3.4 159.0 6.4 2,068 40,939 192.0 261.9 52.3 40.0 165.1 mm 6.500 0.25 300 9,950 7.75 10.69 2.06 0 2 12 0.46 M16x83 7.1 165.1 6.4 2,068 44,258 196.9 271.5 52.3 38.3 3.2 6" 6.625 0.25 300 10,336 7.94 10.69 2.06 2° 10' 0.45 !8" x 31/4"7.1 168.3 6.4 2,068 45,975 201.7 271.51 52.3 - 37.5 M16x83 3.2 216.3mm 8.500 0.25 300 17,024 10.07 13.50 2.31 • 1 -40 0.35 M20 X 121 12A 216.3 6.4 2,068 75,723 255.8 342.9 58.7 29.2 5.6 8.625 0.25 300 17,519 10.19 13.56 2.50 0.35 3/4 x 43/4' 14.5 8 1° 40 219.1 6.4 2,068 77,925 258.8 344.4 63.5 - 29.2 M20 121 6.6 10.750 0.25 250 22,679 12.69 16.38 2.63 0.28 1' x 61/2 28.0 10 1° 20' 273.0 6.4 1,724 100,876 322.3 416.1 66.8 - 23.3 M24 165 12.7 12.750 0.25 250 31,903 14.94 18.88 2.63 0.23 1'x61!2' 36.5 1 2" 1° 7' 323.9 6.4 1,724 141,905 379.5 479.6 66.8 - 19.2 M24 x 165 16.6 * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. ** Gold color coded metric bolt sizes are available upon request. I Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be ½ that of cut grooved. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation `~ 07 instructions (11-1-1 000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Compa TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tqCU /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 577 Rigid Coupling - Patented General Description rressure Kaung ana Listing/Approval Information The Figure 577 Rigid Coupling pro- vides a rigid joint by firmly gripping along the circumference of the pipe grooves. Rigid couplings are preferred for dry pipe and freezer applications. Figure 577 Rigid Couplings are a proven dependable method of joining pipe and are an economical alternative to welding, threading, or using flanges. It is capable of pressures up to 300 psig (2069 kPa) depending on pipe size and wall thickness when used in fire protection services. Rigid Couplings are recommended for dry pipe and freezer applica- tions. WARNING The Figure 577 Rigid Coupling de- scribed herein must be installed and maintained in compliance with this document, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the integrity of this device. The owner is responsible for maintain- ing their system and devices in proper operating condition. The installing contractor or manufacturer should be contacted with any questions. Technical Data Figure: 577 Sizes: 1-1/4 - 8' Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing/Approval in- formation. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12. Protective Coatings: Non-lead orange paint. Fire brigade red (optional) non-lead paint. Hot dipped galvanized conforming to ASTM A-153. Bolts/Nuts: Track Head Bolts - con- forming to ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 psi/758,422 kPa). Metric - conforming to ASTM F568M. Gasket: Prelubricated Grade "A" EPDMA violet color code ambient to +150°F (+66°C) for fire protection systems. Not recommended for hot water sys- tems. Tr-seal (Grade "E" EPDM), green color code for use in dry pipe or freezer system. (See Data Sheet TFP1865 for aid in selecting proper gasket.) Ordering Information When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gas- ket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) or Grade "E" EPDM Tr-Seal, and size. Grinnell Grooved Piping Products, valves, accessories, and other prod- ucts are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire & Building Products. No warranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire & Building Products or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applica- ble Standards of the the standards of any other Authorities Having Jurisdic- tion. Materials found by Tyco Fire & Building Products to be defective shall be either repaired or replaced, at Tyco Fire & Building Products' sole option Tyco Fire & Building Products neith r'- 1 Page 1 of 2 JULY, 2005 TFPI85 Page 2 of 2 TFP1854 assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire & Building Products shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS BE LIABLE, Figure 577 Grooved Coupling IN CONTRACT, TORT, STRICT LI- ABILITY OR UNDER ANY OTHER LE- GAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE & BUILDING PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT B -.--lC - SHALL TYCO FIRE & BUILDING PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- Pipe Max.* :1: End Gap Max. t Pressure Max. t End Load Nominal Dimensions Bolt Net Weight O.D. A B C Size Inches Inches psi Lbs. Inches Inches Inches Size** Dia L X g. Lbs. mm mm kPa N mm mm mm Kg 11/4" 1.660 0.06 300 649 2.68 4.21 1.65 3/8" x2 1/4" 1.3 42.4 1.5 2,068 2,888 68 107 42 M10x57 0.6 11/2" 1.900 0.06 300 851 2.91 4.45 1.65 3/8' x2 1/4" 1.5 483 1.5 2,068 3,783 74 113 42 M10x57 0.7 2" 2.375 0.06 300 1329 3.39 5.00 1.69 3/8' x2 1/4" 1.8 60.3 1.5 2,068 5,912 86 127 43 M10x57 0.8 21/2" 2.875 0.06 300 1947 3.90 5.43 1.77 3/8"x2 1/4" 2.0 730 1.5 2,068 8,663 99 138 45 M10x57 0.9 761 mm 3.000 0.06 300 2121 3.98 5.59 1.77 3/8" x2 1/4" 2.0 761 1.5 2,068 9,433 101 142 45 M10x57 0.9 3fl 3.500 0.06 300 2886 4.49 6.14 1.77 3/8" x2 1/4" 3.3 88.9 1.5 2,068 12,839 114 156 45 M10x57 1.5 4" 4.500 0.19 300 4771 5.71 7.52 1.85 3/8" x2 1/4" 3.3 114.3 4.8 2,068 21,223 145 191 47 M10x57 1.5 5.500 0.19 300 7127 6.81 8.74 1.93 1/2"x3' 5.3 1397 mm 139.7 4.8 2,068 31,704 173 222 49 M12x76 '2.4 5.563 0.19 300 7291 6.85 8.82 1.93 1/2"x3" 5.3 141.3 4.8 2,068 32,434 174 224 49 M12x76 2.4 1651 mm 6.500 0.19 300 9955 7.80 9.76 1.93 1/2"x3' 5.7 1651 4.8 2,068 44,280 198 248 49 M12 76 2.6 6" 6.625 0.19 300 10341 7.91 9.88 1.93 1/2" x 3' 5.9 1683 4.8 2,068 46,000 201 251 49 M12 x 76 2.7 8" 8.625 0.19 300 17527 10.24 12.80 2.40 5/8" x 3 1/4" 11.7 2191 4.8 2,068 77,966 260 325 61 M16x83 5.3 * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire & Building Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. ** Gold color coded metric bolt sizes are available upon request. Max. End Gap is for cut grooved standard weight pipe. Valves for roll grooved pipe will be 1/2 that of cut grooved. Figure 577 Rigid Couplings have an Anti-Rotation Feature of "gripping teeth" along the coupling keys, which make the Figure 577 perfectly suited for "arm over" installations where the likelihood of rotation is greatest. This feature may eliminate the need of extra hangers to support the arm over due to increased rigidity and gripping force saving time and cost. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (I1-1-1000). Never remove any piping component or correct or modify any piping 9001 deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certitied Company TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqC01Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB —28,4.2,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch N PT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. '!l Model/Sprinkler Identification Numbers TYII3I - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.0K, 3l4NPT TY4231 - Pendent 8.0K, 314"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 AUGUST, 2007 (B TFPI7I SSU * DEFLECTOR 1/2' NPT UPRIGHT CROSS SECTION 7/16" :11,1 mm) ¼JOMINAL MAKE-IN 2-3/16" (55,6 mm) 5 4 2 3 * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. TFPI7I ESCUTCHEON 7/16(11,1 mm) STYLE 10or20 PLATE SEATING NOMINAL RECESSED SURFACE 1/2,, MAKE-IN ESCUTCHEON NPT 2-3/16 $EM (55,6 mm) I _______I (38,1 mm) _W L - SSP DEFLECTOR * 2 7/8 (730 mm) DIA PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw Page 3 of 10 FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE NPT MAKE-IN 2-5/16" (58,7 mm) 1-9/16" I (39,7 mm) I SSP DEFLECTOR * 2-7/8" PENDENT RECES STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR 6* 1/2" 5 (1 mm) OMINAL WRENC (57,2 mm) iI4,,NPT 13 m)DIA. PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing b 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 ,-QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Page 4oflO TFPI7I 7/16 (11,1 mm) NOMINAL SSU 1/2 MAKE-IN DEFLECTOR NPT 2-1/4 2-3/16 (57,2 mm) (55,6 4 1-9/16' WRENCH 2 (39,7 mm) FLATS SP* I EFLECTOR CROSS PE NT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 ulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly - Compression orifice seat on frame. Screw FIGURE 5 UICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/p5i1/2 (40,3 LPM/barl'2) K = 4.2 GPM/psi112 (60,5 LPM/barll2) K = 5.6 GPM/psi1/2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/bar112) Temperature Ratings Refer to Table Aand B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. B 25 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED WHITE 1POLYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and 135°F/57"C Orange 1,2,3,4,5,6,7 1,2,3,5 155"F/68°C Red 175°F/79°C Yellow UPRIGHT (TY3131) I200"F/93"C Green I 286°F/141°C Blue NPT RECESSED PENDENT (TY3231)" Figure 10 135°F/57°C Orange 1,2,4, 5 N/A FIE °F/68°C Red 175°F/79°C Yellow 200"F/93°C Green RECESSED PENDENT (TY3231)** Figure 11 135°F/57"C Orange 1,2, 3,4, 5 N/A 155°F/68"C Red 175°F/79"C Yellow 200°F/93°C Green 8.0 3/4', PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2, 3,4, 5,6, 7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231)" Figure 12 135°F/57°C Green 1,2,4, 5 N/A 155°F/68"C Orange 175°F/79°C Red 200°F/93°C Yellow RECESSED PENDENT (TY4231) Figure 13 135°F/57"C Orange 1,2, 3,4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93"C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1,2,4, 5, 6 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286"F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2' RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (1Y4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) UPRIGHT (TY3131) 5.6 OR 1/2' 175 PSI (12,1 BAR) RECESSED PENDENT NPT (1Y3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) RECESSED PENDENT NPT (TY4231) N/A 80 PENDENT (1Y4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141'C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft. lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed TFPI7I - 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4" (19,1 mm (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 FACE OF (57,2 mm) MO TING SPRINKLER PLATE FITTING I 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TYFRB 3/4" (19,1 mm) FIGURE 10 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 m (57,2 mm) FACE OF MO ING SPRINKLER LATE FITTING / 1/8" / (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 13/16" (20,6 mm) FIGURE 12 S IES TY-FRB RECESSED PENDENT WIT 0-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2 (12,7m (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 m) FACE OF (57,2 mm) M TING SPRINKLER PLATE FITTING M 71 / (3,2 mm) ;56K SERIES 1-1/4" (31,8 mm) TY-FRB 1" (25,4 mm) FIGURE 11 Y-FRB RECESSED PENDENT CE 1/2 INCH TOTAL ADJUSTMENT 0 RECESSED ESCUTCHEON -FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/211/8" (73,0 mm) 1/2" (12,7 rum) (12,7±3,2 mm) - 2-1/4" DIA. _-....I 1/4" (6,4 (57,2 mm) FACE OF MO TING SPRINKLER LATE FITTING / 1/8" I - (3,2 mm) _____ II MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY..FRB 1-1/16" (27,0 mm) FIGURE 13 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler, systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. 8 IPERATU RATING 135 135°F/57°C 155 155°F/68°C 175 175°F/79°C 200 200°F/93°C Page 10 of 10 TFPI7I PIN 57-XXX--X-XXX I MODEL/SIN I I .1.. 1 4 3 SPRINKLER 330 2.8K UPRIGHT (1/2"NPT) TYI13I 331 2.8K PENDENT (1/2"NPT) TY1231 NATURAL BRASS 340 4.2K UPRIGHT (1/2"NPT) 1Y2131 WHITE POLYESTER 341 1 4.2K PENDENT (1/2"NPT) 1Y2231 WHITE (RAL9010)* E370 5.6K UPRIGHT (1/2"NPT) TY3131 9 CHROME PLATED 286 286°F/141°C 371 5.6K PENDENT (1/2"NPT) TY3231 I 7 LEAD COATED 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) TY4931* TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any, other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table 0). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 001/020 SWAY BRACE MODEL E SIZE - Pipe to be braced: 1" thru 8" Steel SCH 7 thru 40 IPS. Pipe used for bracing: 1" and 1 1/4" SCH 40 IPS. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized, H.D.G. and Stainless Steel. LISTING - UL in US and CANADA. Only for use with other AFCON bracing products. APPROVAL - OSHPD pending. PATENT - No. 3,570,794 FUNCTION - For bracing pipe against sway and seismic disturbances. The sprinkler pipe attachment component of a lateral sway brace assembly, consisting additionally of AFCON 70 series attachment end joined with brace pipe sized per N.F.P.A. INSTALLATION - Place Model E over pipe to be braced. Insert brace pipe through MODEL "E" under channel bracket, leaving 1" minimum extension beyond. Tighten both hex nuts until gage spring lays flat. Install as a lateral sway brace per N.F.P.A. FEATURES * UL Horizontal Load Ratings: 2015# Sch. 10 thru 40, All Sizes 655# Sch. 7 - 1" thru 4" 1500# Sch. 7- 6" * Can be used as a 4-way sway brace. * Visual inspection, proper installation when gage spring lays flat. ORDERING - Part #, Pipe size to be braced, Brace pipe size and Index 02/01 (B AFCON PART # 076 410 (B 076 UNIVERSAL LOCKING ATTACHMENT END SIZE - One size fits 1 thru 2 inch bracing pipe, 12 GA. strut channel and all structural steel up to 1/4". thick. Use in combination with I thru 8 inch AFCON sway braces. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and H.D.G. LISTING - UL in US and CANADA. Only for use with other AFCON bracing products. APPROVAL - OSHPD pending. PATENT - Pending. FUNCTION - For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace assembly, consisting additionally of AFCON 001 thru 40 series sway brace joined with bracing pipe sized per N.F.P.A. INSTALLATION - Insert brace component into fitting. Tighten set screw until it contacts tightly against the fitting. Install per N.F.P.A. FEATURES * UL Horizontal Load Rating: 2015# * Fits multiple sizes of plain end brace pipe, strut or structural steel. * Swivel design allows attachment at any angle. * Visual inspection, proper installation when set screw head contacts Bracket. ORDERING - Part #, pipe size and finish. Index 03/01 WIAc!n 300 RING HANGER <jq> C®US I thru 4 inch pipe 1/2 and 314 Inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H- 171(Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru 3 inch: * UL listed to accept AFCON #310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE ROD 1/2 3/8 400 10 3/4 400 20 10 l 3/8 400 25 10 3/8 400 32 10 11/2 3/8 400 2 3/8 400 10 21/2 3/8 600 10 3 600 80 10 31/2 3/8 600 10 4 3/8 1000 100 5 112 1250 125 12 6 1250 150 12 8 1250 Order Part #300m Note: 1/2' Ring Hanger not <FM> approved 310 SURGE RESTRAINER Ring Hang estrainer SIZE - Fits 3/4 thru 4 inch Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING - UL in US and CANADA. Only listed for use with AFCON Ring Hanger. FUNCTION - Used with Ring Hanger to restrict upward movement of piping. Use with steel or C.P.V.C. pipe. INSTALLATION - Snap into locking position on swivel nut of Ring Hanger. Install or remove without tools. FEATURES - Ring Hanger may be adjusted with Surge Restrainer installed. ORDERING - Part #. Index 12/00 ( D 410 PIPE CLAMP FOR SWAY BRACING SIZE - 1 thru 8 inch pipe. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized, H.D.G. and Stainless Steel. LISTING - UL in US and CANADA Only for use with other AFCON bracing Products. APPROVAL - OSHPD pending. FUNCTION - For bracing pipe against sway and seismic disturbances. The pipe attachment component of a longitudinal sway brace assembly, consisting additionally of AFCON 70 series attachment end joined with bracing pipe sized per N.F.P.A. INSTALLATION - Place #410 over pipe to be braced and bolt together. FEATURES * UL Horizontal Load Rating: 1-3 pipe size = 500# 4-8 pipe size = 2015# * Made with 1/2" bolts to conform with sway brace fittings. * Can be used as a 4-way sway brace. ORDERING - Part #, Pipe size and Finish. Ifl d ex Part U 41( 02/01 01 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1510 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in linch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 8 i #14 (Item #100-black) Sammys 1/4,3/8" rod WOOD — Sammys 1•II rIi" Rod (Ve ilicali.N1rrniim Use #14 Nut Driwr (Item #100) Item # Model Shk Lgth Shk Dia Box Qty 1 Weight (per 100) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 6.50 1000 23 GST 300 3 1/4 100 7.50 1000 24 GST 600 6 1/4 50 9.00 500 S NE WOOD ii1 .i& rrniim Use #14 Nut Driver (Item #100) Approuls Item # Model Shk Lgth Shk th FMTest Load, lb. ULTest Load lb. ULIFMa Pipe Size Actual Pullout Box Qty 10 GST.75 3/4 1/4 564#-6Ply 100 NFPA 11 GST 10 1 1/4 210# - 7/16 OSB100 670# - 3/4" Ply UL-FM-NFPA 12 GST20 2 1/4 9404 850# 3/4-2 1/2 1760# - Fir 100 UL-NFPA * 27 GST 25-380 21/2 3/8 15004 4 2113# - Fir 50 UL-FM-NFPA 13 GST 30 3 1/4 14754 1500# 3/4-4 2060# - Fir 100 NFPA 403 GST40 4 1/4 2180# - Fir 50 NFPA 14 GST6O 1 6 1/4 2230#-Fir 1 50 Consult truss manufacturer for recommended installation point *pre_drilling may be required for items #27 and #06. Tools available on page 9. 'C Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance Note: Screws must be installed with appropriate nut driver to comply with warranty Page 4 [_UL Listings and CAD Drawings are available at www.SammySuperScrew.com I&IIII] FEIRod T(Horizontal I flhliti Use #14SW Nut Driwr (Item #101) Item# Model Shk Lgth I 1 Shk Actual Actual I Box Qty I I Weight I Case Qty (per 100) I I 4016 SWG1001 1 1/4 100 7.50 I 1000 300 ISWG200 2 1/4 17254-Fir 100 8.00 1000 WOOD - 3/8 1T Ifi 1111 yAaui1 L flTTITI Use #14SWNut Driver (Item #101) Appro'uls Item # Model Shk Lgth Shk Dia UL Test Load lb. UIJFM Pipe Size Actual Box Shear/Pullout Qty Weight (per 100) 18 SWG10 1 1/4 100 6.00 UL•NFPA 19 SWG20 2 1/4 12504 3 1725# - Fir 100 7.00 UL•NFPA * 26 SWG25-380 2 1/2 3/8 15004 1 4 2249# - Fir 1 50 10.25 - 25 SWG30 3 1/4 50 8.50 #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod #14 (Item #100-black) Sammys 1/4", 3/8" rod Prestressed Concrete +c: (B Page 5 WOOD—Sidewinders Not less than 2" nominal width (11/2") up to 3 1/2" pipe; not less than 3" nominal width 4" & 5" pipe Floorjoist r TJI Joist/Truss Consult truss manufacturer for recommended installation point. *pre_drilling may be required for item #26. Tools available on page 9. 13 SHEETROCK Minimum 2 1/2" from bottom for branch lines. Minimum 3" from bottom for mainlines. Exception: This requirement shall not apply to 2" orthlcker nailing strips resting on top of steel beams. - Toggle I iiSHEETRIOCK - 1/4" Rod (Vertical Mount) Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia I Actual Pullout Box Qty I Weight I Case Qty (per 100) I 71 SST 300 3 1/4 4504 Lath & Plaster 50 12.00 I 500 4044 2 Layers 5/8 Rock J ii :1 i 1iI yk 1T (Vertical Mount) Use #14 Nut Driver (Item #100) Item# Model Shk Lgth Shk Dia Actual Pullout Pkg Qty Weight I Case Qty (per 100) I 70 3 1/4 450# Lath & Plaster I 50 I 12.00 I 500 ISST 30 404# 2 Layers 5/8 Rock j Note: Screws must be installed with appropriate nut driver to comply with warranty