HomeMy WebLinkAbout5823 NEWTON DR; ; FPC2017-0382; Permit7c(tyof PERMIT REPORT Cdrlsbad Print Date: 12/14/2020 Permit No: FPC2017-0382 Job Address: 5823 NEWTON DR, CARLSBAD, CA 92008-7361 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120504300 Track #: Applied: 12/27/2017 Valuation: $1,413,904.00 Lot #: Issued: 01/10/2018 Occupancy Group: Project #: Finaled Close Out: 12/14/2020 #of Dwelling Units: Plan #: Bedrooms: . Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: THERMO FISHER -FIRE ALARM TI AT PHASE 1 NORTHEAST OFFICE AREA FPContractor: JMG SECURITY SYSTEMS 17150 NEWHOPE ST, # 109 FOUNTAIN VALLEY, CA 92708-4273 (714) 545-8862 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov HIGHLIGHTED SET UL & FM Certificates of Compliance 'F PC 2bl:r- 0382. Cut Sheets and CSFM listings Thermo Fisher S C I E N T I F I C Phase I Tenant Improvements 5823 Newton Drive, Carlsbad, CA 92008 Installation Company: ,j MG SECURITY SYSTEMS Our service is your security. 17150 Newhope Street Fountain Valley, CA 92708 (714) 545-8882 U Applicant ID No 257057-001 Service Center No: I Expires: 31-MAR-2018 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate Listed Service From: LAKE FOREST, CA Alarm Service Company: (257057-001) Service Center: (257057-001) ADVANCED PROTECTION INDUSTRIES INC, ADVANCED PROTECTION INDUSTRIES INC, OBA NATIONAL MONITORING CENTER DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR 25341 COMMERCENTRE DR LAKE FOREST CA 92630 LAKE FOREST CA 92630 The Alarm Service Company is Listed in the following Certificate Service Categories File -Vol No. CCN Listing Category BP10307 I CRZM Monitoring Stations, National Industrial Security 581261 UUFX [Signal and Fire Alarm Equipment añdServicés] (Protective Signaling Services) Central Station I . 7 . ULLLC CERTIFICATE OF COMPLIANCE COVER PAGE MRTSHUFF Applicant Subscriber No: 257057-001 ADVANCED PROTECTION INDUSTRIES INC, Service Center Number: 1 DBA NATIONAL MONITORING CENTER Service Contract No: - 25341 Commercentre Dr ACTIVE LISTINGS Lake Forest CA 92630 CCN File No. Vol. No. UUFX S8126 1 CRZM BP10307 1 Listed Service From: LAKE FOREST, CA Alarm Service Comoan ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 01-APR-15 SILENT KNIGHT lntelliKnight® Model 5820XL 130 Addressable Fire by oneyvveII Alarm Control System The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits 13 pie-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL signal line circuit (SLC) supports multiple device types of the same protocol: SK (System Sensor) SD You cannot mix SD and SK SLC devices on a FACP. lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, inluding: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (SK protocol only) Addressable multi-criteria smoke detector (SK protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the IntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The lntelliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows® based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved 5*ISXL acor IF 5*60 noleommuricsoor 6*24 rOerJGone/ I/OdU 2 UiL Ma3&jO) ud.$ao,.IIOfl. .nAI Nd lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Wndfa% Based InteHiKnight582OXL Facillitty Addressable Fire Alarm System Uanigsm.nt$oftwsri SK (System Sensor) Protocol Devices Wr6ws6snsd L!PomnIoed Stwsr• ftJ1 3~22 JJ Compitib in Reodvur SMAre 0' kbrnet 5$20XL SK.212UD Connection VwAlarm IP Communicator 6*I5xl. __________ tnehmt PcnerModul. 3F Relays mzOb Wolfitx h1ouIO Nnron RG WOW Irt9taC tIacor MO0L0 noncor MO2JO *l-Pt2OtOT U-0mortor M14999 SK44e-ROR ROIe/ I — Aoote Module tdMoror S44t4IT BM 13— coo. WO Rd ,u ÔmaUe rwedar 11000000001000 6883 sK.eeMn SK.Mun-lO KPtOA *KDI1 Q4.IilmOn Icctr4 SKZone ac.ftday M0000do ccP.ill-SA 00000o000t10 1010100. P,OCorool AdousaOa Ado00onD A000.*0000 Mnnitro M1e.o 11oc1 Module Modulo In100Moe Relay 800*001e1tO1 Module PuIlS10000 todeclm hludide 1100000 5855.4cr 5865.3 i Use the 5$6010 control upto4 1 J Itodolo Intellil(night Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiation Circuits: 100 mA@ 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5W x 24.75"H x 3.9"D (36.8W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 A max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S-BUS Accessories 58601R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the lntelliKnight system. 5820XL supports three 5815XL's. Each 5815XL can support 99 5K detectors and 99 5K modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) 5D505-DTS-K Remote test switch. Used with SD505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and 5K Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 SK Devices Data Sheet D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 by Honeywell Phone: (203)484-7161, Fax: (203) 484-7118. www.silentknight.com IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight Made in America PNJ 350210 Rev H2 © 2012 Honeywell International Inc. 5D505-APS (Base not included) SD505-DUCTR A duct smoke detector that detects smoke and products of combustion present in air moving through an HVAC duct. The SD505- DUCTR provides a fully programmable Form C contact. This duct detector is housed in a heavy duty metal housing with a preinstalled 5D505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the detector communicates the condition to the SD505-DUCTR D SILENT KNIGHT by Honeywell Analog/Addressable Devices with Hochiki (SD) Protocol SD Devices SD devices are intelligent analog/addressable devices for use with the following IntelliKnight addressable fire alarm control panels (FACPs): 5820XL, 5808 and 5700. SD detectors, modules, and accessories communicate to the FACP over the signaling line circuit loop (SLC loop) using a two wire connection. Shielded or twisted wire is not required. Up to 127 addressable SD devices can communicate with the FACP on a single SLC loop. Any combination of addressable SD devices and SD modules can be used on a single SLC loop. The assortment of SD detectors, modules, and accessories that are compatible with IntelliKnight addressable FACPs are described below. For detailed information on SD devices, see the device specification sheet. SD505-AIS An ionization smoke detector that has a sampling chamber and reference chamber for high stability and for a variety of applications where early warning of trouble from r U super-heated or flaming combustibles is desired. Presence of / visible smoke or invisible gases greatly influences the current flow in SD505-AIS the sampling chamber, changing the (Base not included) voltage ratio between the chambers. The difference is amplified inside the detector. When reaching a critical level, the detector triggers an alarm. SD505-DUCT A addressable duct smoke detector that detects smoke and products of combustion present in air moving through an HVAC duct. This duct detector is housed in a . . \ heavy duty metal housing with a preinstalled 5D505-APS C.. / photoelectric smoke detector. 5D505-DUCT has an air / ) velocity rating from 300 feet per minute to 4,000 feet per * minute. Order 5D505-12, 5D505-T5, or 5D505-T10 air - sampling tubes separately. FACP. The built-in relay module then turns off fans, blowers, and other devices. SD505- DUCTR has an air velocity rating from 300 feet per minute to 4,000 feet per minute Order SD505-12, SD505-T5, or SDSOS-TI 0 air sampling tubes separately. Optional 5D505-DTS-2 remote test switch available. Detectors SD505-APS A photoelectric smoke detector. 5D505-APS has an LED light source and silicon photo diode receiving element. The detector features automatic drift compensation for contamination and a simple detector calibration test procedure that can be run at the FACP or remotely using 5650/5651 Silent Knight Software Suite. SD505-AHS A fixed temperature heat detector that uses an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. SD-505-AHS offers a programmable trip point temperature from 135°F - 150°F (57°C - 651C). This detector is well suited for environments where smoke rfrtr.tnrs cannot be used because of the presence of 5D505-AHS (Base not included) steam or cooking fumes, such as in a kitchen. SD Devices Modules SD500-AIM TY 71 A dry contact input module that acts as an . IHHl interface to contact devices, such as a waterfiow switches and pull stations. The 0 0 SD500-AIM supports Class B supervised 1 wiring.This module monitors for alarm contact closures and open circuit wiring fault conditions. Mounts in a 4" square box. SD500-AIM SD500-MIM A compact and light weight monitor module that acts as an interface to contact devices, such as waterfiow switches and pull stations. The SD500-MIM supports Class B supervised wiring. This module mounts in a single gang box. SD500-ARM A relay module that provides one relay with two Form C contacts rated at 2.OA @ 30 VDC or 0.6A @ 120 VAC. The SD500-ARM can control a wide variety of normally open or normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. SD500-ANM A notification module that lets you add notification circuits wherever they are needed on an FACP SLC loop. The SD500-ANM provides supervised monitoring of wiring to load devices such as bells, horns, and strobes. You can supply power to this module near the signaling appliance to reduce wire gauge requirements or supply power from a main power supply and control it separately by the individual notification modules. The SD500-ANM supports Class B and Class A wiring and all 16 notification patterns available on the FACP. SD500-SDM A two-wire interface module that allows an FACP to interface with and monitor two-wire conventional devices. This means you can retrofit an existing building and use existing conventional devices, including two-wire smoke detectors and devices with dry contacts, such as pull stations and heat detectors. The SD500-SDM transmits the status condition (normal, open, or alarm) of one full zone of two-wire devices to the FACP. The SD500-SDM supports Class B and Class A wiring SD500-LIM A line isolator module that isolates a short circuit wiring fault on an SLC .. I loop. When a short occurs on the SLC loop, it is detected as a trouble but all * of the SLC devices protected by a - SD500-LIM will continue to operate. . SD500-LIM SD500-LED An LED driver module that connects to the SLC loop and is capable of driving 80 LEDs. lntelliKnight FACPs support up to 40 S1,500-LEDs per SLC loop. Accessories SD500-PS/SD500-PSDA The SD500-PS is a single action pull station requiring only one motion to activate the station. The SD500-PSDA is a dual action pull station requiring two motions to activate the station. Both pull stations feature a rugged metal construction and mount in a single gang box. SD505-DTS-2 SD500-PS A remote test switch for use with the SD505-DUCTR that provides remote key operated test function and annunciation of detector alarm. SD505-6SB A 6" mounting base adds an audible output function to SD505- APS, SD505-AIS, and SD505-AHS. The SD505-6SB can be used as a single station, multi-station, or as a system sounder. SD505-6RB A 6" mounting base with one Form C relay contact. The SD505- 6RB lets you control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. Because this relay is addressable, the relay device can be located at any point on the SLC loop. SD505-61B A 6" mounting base with a built-in isolator for SD505-APS, SD505-AIS, and SD505- AHS detectors. When the SD505-61B is connected to the SLC loop, a short, open, or ground fault occurring on the SLC loop . is detected as a trouble but all SLC devices continue to operate. SD505-61B .. - fits under 3D505-6AB detector base (included). SD505-61B Isolator Base SD505-6AB A 6" mounting base is for use with SD505-APS, SD505-AIS, and SD505-AHS. SD505-4AB A 4" mounting base is for use with SD505-APS, SD505-AIS, and SD505-AHS. SILENT This document is not intended to be used for installation purposes. We try to keep KNIGHT D our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, by Honeywell Northiord, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA PN 53624 Rev B2 © 2010 Honeywell International Inc. 0 1-1- 0 Route all low voltage wiring through any of these kriocl<outs. lo Before You Begin Installing To AC Input - .- J.:—tJ. 1I i Zn J MainT4 - :7 qtte~ urider ihum osag I spacingetween ----- --— batten cal4es All circuits, exce t battery an input wiring.cables anc AC, are ower limited. Maintain at least 1/4 spacing between power limited an1 non-power limited circuits. Separate high and low lack voltage circuits. ------------------- ----------------------- Fire alarm power-limited circuits are 'installed using types FPL, FPLR, FPLP or permitted substitute cables, provided these power-limited cable i conductors extending beyond the I jacket are separated by a minimum of 0.25 in. (6.35 mm) or by a nonconductive sleeve or nonconductive barrier from i all other conductors. Figure 3-1 Wire Routing Example 151209 3-5 0 0 0 sis iting Switch it og ramming ts C M N lnteiiKnight 5820XL Installation Manual 3.5 Board Assembly Diagram On-board Annunciator To AC 4 Figure 3-2 Model 5820XL Assembly Figure 3-2 shows the circuit boards, metal housing and annunciator that attach the 5820XL assembly to the cabinet. If you should need to remove the board assembly for repair, remove the four mounting nuts which hold the assembly in the cabinet. Then lift the entire assembly out of the cabinet. Do not attempt to remove the circuit boards from the metal bracket. 3-6 151209 Intel/Knight 5820XL Installation Manual 3.6 Calculating Current Draw and Standby Battery This section is for helping you determine the current draw and standby battery needs for your installation. 3.6.1 Current Draw Worksheet Requirements The following steps must be taken when determining 5820XL current draw and standby battery requirements. You will use the Current Draw Worksheet to determine current draw and standby battery requirements. Use Table 3-1 if installing SK SLC Devices and Table 3-2 if installing Hochiki SLC Devices. For the 5820XL, the worst case current draw is listed for the panel, addressable devices, and all SBUS expanders. Fill in the number of addressable devices and expanders that will be used in the system and compute the current draw requirements for alarm and standby. Record this information in the Current Draw Worksheet on Line A. Add up the current draw for all auxiliary devices and record in the table at Line B. Add up all notification appliance loads and record in the table at Line C. For notification appliances and auxiliary devices not mentioned in the manual, refer to the device manual for the current ratings. Make sure that the total alarm current you calculated, including current for the panel itself, does not exceed 6.0 A. This is the maximum alarm current for the 5820XL control panel. If the current is above 6.0 A you will need to use a notification power expander(s) such as the Silent Knight 5495 or the 5895XL intelligent power expander, to distribute the power loads so that the 5820XL or the power expanders do not exceed their power rating. Refer to the current draw worksheets provided with the 5495 or the 5895XL manuals so you do not exceed their power requirements. 6. Complete the remaining instructions in the appropriate Current Draw Worksheet for deter- mining battery size requirements. 3-6 151209 Before You Begin Installing 3.6.2 Current Draw Worksheet for SK SLC Devices Use Table 3-1 to determine current requirements during alarm/battery standby operation when SK SLC devices are installed. You can install up 99 SK detectors per loop (396 max per panel) and 99 SK modules per loop (396 max per panel). Copy this section if additional space is required. Table 3-1: Current Draw Worksheet for SK SLC Devices Device #of Devices Current per Device Standby Alarm Current Current For each device use this formula: This column X This column = Current per number of devices. Fire Panel (Current draw from battery) I I Standby: 215 mA 215 mAl I Alarm: 385 mA 385 mA Addressable SLC Detectors SK-Photo (99 max/loop & 396 max! panel)' Standby/Alarm: 0.27 mA mA mA SK-Photo-T mA mA SK-Ion mA mA SK-Heat mA mA SK-Heat-HT mA mA SK-Beam (without integral test) SLC Standby! Alarm: 2 m Aux. Pwr Standby: 2 mA mA Alarm: 8.5 mA mA SK-Beam-T 5(with integral test) SLC Standby! Alarm: 2 m Aux. Pwr Standby: 2 mA mA Alarm: 8.5 mA mA SK-Duct6 SLC Standby/ Alarm: 0.27 mA mA mA SK-Acclimate Standby/Alarm: 0.3 mA mA mA SK-Heat-ROR mA mA 151209 3-7 lntelliKnight 5820XL Installation Manual Device # of Devices Current per Device Standby Current Alarm Current Addressable SLC Modules SK-Control (99 max/loop & 396 max! panel)' SLC I Standby! 0.375mA mA I Alarm 0.375mA mA Aux Pwr I Standby! 1.7mA I mA Alarm: 7mA mA SK-Monitor Standby/Alarm: 0.375 mA mA mA SK-Minimon mA mA SK-Pull-SA mA mA SK-Pull-DA SK-Monitor-2 Standby/Alarm: 0.75 mA mA mA SK-MonlO Standby/Alarm: 3.5 mA mA mA SK-Relay-6 Standby/Alarm: 1.45 mA mA mA SK-Control-6 SLC Standby! 2.25 mA mA Alarm: 2.25 mA Aux Pwr Standby! 1.7 mA mA Alarm: 20 mA mA SK-Relay Standby/Alarm: 0.255 mA mA mA SK-Zone Aux Pwr Standby 12 mA mA Alarm 90 mA mA SLC Standby/ Alarm 0.27mA mA mA SK-Zone-6 Aux Pwr Standby 50 mA mA Alarm 270 mA mA SLC Standby/Alarm 2 mA mA mA SLC Accessories B501BHT-2 Sounder Base (99 max/loop & 396 max! panel) Aux Pwr Standby: 1 mA mA Alarm: 15 mA mA SLC Alarm: 0.7 mA mA B224RB Relay Base Standby/Alarm: 0.5 mA mA mA RTS151!151KEY Alarm: 7.5 mA mA RAIOOZ Alarm: lOmA mA SLC Isolator Devices SK-Iso (Isolator Module) 1(100 max/loop I I &400 max! panel) Standby/Alarm: 0.45 mA mA mA B224B1 Isolator Base Standby/Alarm: 0.5 mA mA mA Accessories Modules 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA 5860 Remote Fire Alarm Annunciator (8 max) Standby: 20 mA mA Alarm: 25 mA mA 5824 Serial/Parallel Printer Interface Module (2 max.) Standby/Alarm: 45 mA mA mA 5496 Intelligent Power Module (8 max.) Standby/Alarm: 10 mA 5895XL IntelliKnight Power Module Standby/Alarm: 10 mA mA mA 3-8 151209 A IV C D E F G H I J Before You Begin Installing Device # of Devices Current per Device Standby Current Alarm Current 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 I/O Module Standby: 35 mA mA Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA mA Alarm: 220mA (22 mA per relay) mA Total System Current Auxiliary Devices3 Refer to devices manual for current rating. Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Notification Appliance Circuits Refer to device manual for current rating. Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines E and F. Total standby AU AH Alarm sounding period in hours. (For example, 5 minutes =.0833 hours) H Multiply lines E and H. Total alarm AU AH 4 Total ampere hours Add lines G and I. required AH 1. Total does not include isolator devices or accessory bases. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. SK-Beam-T draws a maximum of 500mA from Auxiliary power only when the test feature is used. this should be considered when determining auxiliary power capacity but not calculated into current requirements for day to day operation. The SK-Duct housing contains a vacant mount for a SK-Relay (sold separately). Current draw for the SK-Relay is calculated by increasing the SK-Relay row of the calculation sheet by one for each SK-Relay used with a SK-Duct. 151209 3-9 lntelliKnight 5820XL Installation Manual 3.6.3 Current Draw Worksheet for Hochiki SLC Devices Use Table 3-2 to determine current requirements during alarm/battery standby operation when Hochiki SLC devices are installed. You can install up 127 Hochiki devices per loop (508 max per panel). Copy this section if additional space is required. Table 3-2: Current Draw Worksheet for Hochiki SLC Devices Device # of Devices F Current per Device Standby Current Alarm Current For each device use this tormula: this column X This column = Current per number of devices. IntelliKnight 5820XL Fire Panel (Current draw from battery) IStandby: 215 mA I 215 mA Alarm: 385 mA 385 mA Addressable SLC Devices SD500AIM (508 max.)' Standby/Alarm: 0.55 mA mA mA SD500-MIM mA mA SD500-PS SDSOO-ARM mA mA SD505.AHS mA mA 5D505AIS mA mA SD505-APS mA mA SD500.ANM (508 max.)' Aux. Pwr Standby: 8 mA mA Alarm: 60 mA mA ______ SLC Standby/ Alarm: .55 mA mA mA SD500SDM (508 max.)' SLC Standby/ Alarm: .55 mA mA mA Aux. Pwr Standby: 20 mA mA Alarm: 106 mA mA SD500-LED (100 max.)' Aux. Pwr Standby: 10 mA mA Alarm: 220 mA mA LED: 10 mA mA mA SLC Standby/ Alarm: 0.55 mA mA mA SLC Accessory Bases 5D505-6RB (508 max.) Standby/A ram: .082 mA mA mA 5D505-6SB (508 max.) Aux. Pwr Standby: 1 mA mA Alarm: 32 mA mA SLC Standby/ Alarm: .082 mA mA mA 5D505.ADHR 5D505.DUCTR (508 max.) Aux. Pwr ______ Standby: 35 mA2 mA Alarm: 75 mA2 mA SLC Standby/ Alarm: .082 mA mA mA 5D505-DTS 5D505-DTS.K (508 max.) None, included with 5D505-ADHR worst case. 5D505-ADH SD505-DUCT (508 max.) None, included with detector current. SLC Isolator Devices SD500-LIM (1024 max.) Standby/Alarm 0.092 mA I mA I mA I 5D505-61B (508 max.) Accessories Modules 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA 5860 Remote Fire Alarm Annun. 5860 (8 max.) Standby: 20 mA mA - I Alarm: 25 mA j mA 3-10 151209 Before You Begin Installing A IF C D E F G H J Device # of Devices Current per Device Standby Alarm Current Current 5824 Serial/Parallel Printer Interface (2 max.) Standby/Alarm: 45 mA mA mA 5895XL IntelliKnight Power Expander (8 max.) Standby/Alarm: 10 mA mA mA 5496 Intelligent Power Module Standby/Alarm: 10 mA mA mA 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 LED I/O Module Standby: 35 mA mA Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA mA Alarm: 220 mA (22 mA per relay) mA Total System Current Auxiliary Devices3 Refer to devices manual for current rating. Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines E and F. Total standby AH AH Alarm sounding period in hours. (For example, 5 minutes =.0833 hours) H Multiply lines E and H. Total alarm All All 4 Total ampere hours Add lines G and I. required All Total does not include isolator devices or accessory bases. If using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC, 120 VAC or 240 VAC. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. 151209 3-11 Intel/Knight 5820XL Installation Manual 3.6.4 Maximum Battery Standby Load Table 3-3 shows the maximum battery standby loadfor the 5820XL based on 24 and 60 hours of standby. The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-1 for SK devices and Table 3-2 for Hochiki devices) must be less than the number shown in Table 3 -3 for the battery size used and standby hours required * 33AHmax battery size for FM (Factory Mutual) installations.. Table 3-3: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm *Max Load for 60 hrs. Standby, 5 mins. Alarm 7 A 270 m 105 m 12 A 475 m 190 m 18 A 685 m 270 m 35 A 1.3A 540 m * Requiredfor NFPA 72 Auxiliary Protected Fire Alarm systemsfor Fire Alarm Service (City Box) andRemote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter (DACT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-3. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the required 24 hours standby power. Use Table 3-3 to calculate the correct battery amperes/hour rating needed for your installation. 3.7 Installation Tasks Overview This section provides a chart listing tasks that need to be performed when installing the IntelliKnight 5820XL system. The chart is intended to be a handy way for you to make sure you have completed all necessary tasks. Unless noted, these tasks do not have to be performed in the order they are listed here. Important: Connect and address SLC devices before running JumpStart. Task See Sec. (for more info.) Main Panel Hardware Installation El Mount the control panel cabinet. 4.1 El Connect AC. 4.2 El Connect phone lines. 4.11 El Install 5815XL SLC expander modules (if needed). Required if more than 127 SLC devices are used. 4.6 El Install 5860 Remote Fire Alarm Annunciator modules if used. 4.5 El Install 5865 or LED Annunciator modules if used. 4.9 El Install 5880 LED I/O module if customized LED annunciation will be used. 4.8 El Install notification appliances. 4.13 El Install auxiliary power devices (if used). 4.13.5 El If using a printer, install the 5824 Serial/Parallel Printer Interface Module. 4.7 El Connect batteries (typically last step). 4.3 3-12 151209 5815XL Specifications System Capacity 5820XL FACP supports three 5815XL SLC Expanders. Each expander supports 99 SK detectors and 99 SK modules or 127 SD addressable devices. Operating Voltage 24 VDC Current Draw 55 mA minimum - 125mA max. Ambient Temp. 32°F to 120°F (0°C to 49°C) Mounting Inside 5820XL, 5895XL cabinet, or 5815RMK cabinet D SILENT KNIGHT by Honeywell Model 5815XL Signaling Line Circuit Expander Add flexibility to lntelliKnight® applications with the 5815XL SLC Expander The Model 5815XL SLC Expander is a signaling line circuit controller for Silent Knight's lntelliKnight 5820XL FACP or 5820XL-EVS FACP with Emergency Voice System. It allows you to add 99 SK modules and 99 SK devices or 127 SD addressable devices to the lntelliKnight system. Add up to three 5815XLs to a system to achieve the maximum number of devices on the system. 5815XL signaling circuits have the same functionality as the SLC that is built into the lntelliKnight panel and support the same addressable devices as the main panel. The 5815XL connects to the panel via the RS 485 bus. Model 5815XL Signaling Line Circuit Expander The 5815XL expands the capabilities of the lntelliKnight fire control panel by allowing an additional 99 SK modules and 99 SK detectors or 127 SD addressable devices to be attached to the system. All functionality of the built-in SLC is provided with the 5815XL. Three 5815XLs can be added to an 5820XL or 5820XL-EVS lntelliKnight system for a total of 396 5K detectors and 396 SK modules or 508 SD addressable devices per system. Operation The 5815XL communicates with the lntelliKnight FACP via an RS 485 system bus. A green LED on the 5815XL board blinks to indicate good communication. If an addressable device on a 5815XL fails, the loop communicates the failure to the panel and continues to operate normally. Features Adds 99 SK modules and 99 SK detectors or 127 SD addressable devices to an 5820XL/EVS lntelliKnight system Three 5815XLs per system 5815XL SLCs have same functionality as the 5820XL/EVS, including Style 6 (Class A) configuration Communicates with the lntelliKnight panel via RS 485 system bus LED indicates good communication UL 864 listed, complies with NFPA 72 and 101 Communicates on most standard wiring systems (ideal for retrofits) FM approved; CSFM approved; MEA 5815XL sC- s+sC- s+ - + A B IN OUT 0000 L1J V ID SIC Used for Loop 5(yfo6SLC Coolgurotion 23 22 21 20 19 18 Used In Class A configurations Model 5815XL SLC Expander Engineering Specifications The contractor shall provide a signaling circuit expander compatible with the lntelliKnight 5820XL fire control panel that allows 99 SK Modules and 99 SK Detectors or 127 SD addressable devices to be added to the system. The lntelliKnight panel shall support three expanders per system. The expanders shall provide signaling line circuits that have the same installation and functionality as built-in SLCs and shall communicate to the main panel via an RS 485 system bus. A green LED on the expander board shall blink to indicate communication with the main panel. 5815XL Block Diagram SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA D KNIGHT to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350098 Rev G subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 © 2013 Honeywell International Inc. Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.siIentknight.com SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an lntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your lntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence Install up to twelve 5860s per 5820XL/EVS or 5808 system Install up to eight 5860s per 5700 system Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color 5860R: Red 5860: Gray 5860 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Compatibility The 5860 is compatible with the following FACP's: 5820XL Addressable Fire Control Panel 5820XL-EVS Fire Control Panel with Emergency Voice System 5808 Addressable Fire Control Panel 5700 Addressable Fire Control Panel PN 350224 Rev G © 2014 Honeywell International Inc 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP SBUS 5860 5860 5860 Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System Up to Eight 5860s Per 5700 System Compatible lntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559:135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all D specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYI985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor InteIliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SDSOO-ANM : Addressable Notification Module SDSOO-LIM: Line Isolation Module SD505-6113: Isolation Base SD-500 SDM: Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB : Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT © by Honeywell SD500-AIM & SD500-MIM Addressable Input Modules InteIliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description DIP switch programmable for fast The SD500-AIM and SD500-MIM are installation addressable input modules for use with • Up to 2500 ft wiring distance from the lntelliknight fire alarm control either input module to contact c1t panels (FACPs). The SD500-AIM Use up to 14 gauge wire 10. 0 Jij addressable input module mounts to a UL listed 4-square box. The SD500-MIM mini input module fits inside a single gang Electrical Specifications box. Both input modules are designed Standby Current: 0.55 mA switches, and other applications device; 46 mA max for o devices; sD500AlM to be used with pull stations, water flow Alarm Current: 23 mA max for one devices. requiring dry contact alarm initiation 0.55 mA for each additional device These modules are supervised, single Line Resistance: 502 max input contact monitors. Using an EOL Mechanical Specifications resistor, they monitor for alarm contact SD500-AIM Physical Description closures and for open circuit wiring Dimensions: fault conditions. If a fault occurs in the 4.9" W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4w x 12.4 H x 2.5D cm) SD500.MIM Each addressable input module is Weight: 3.6 oz (120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500-MIM Physical Description Approvals Features Dimensions: NFPA 71 & NFPA 72 Single contact monitor 1.5" W X 2.5" H x.0.7" D, UL 864 (3.8 W 6.4 H 1.8 D cm) SDSOO-AIM supports Class A (Style CSFM 7300-0559: 132 D) or Class B (Style B) contact Weight: 1.6 oz (45.4 g) MEA 429-92-E Vol. IX monitor wiring Environmental FM Approved for use with the 5820XL SD500-MIM support for Class B Operating Temperature: (Style B) contact monitor wiring 32°F - 120°F (0°C - 49°C) Attractive ivory cover plate with the SD500-AIM Humidity: Small and lightweight size allows for 10% - 93% non-condensing flexible mounting options with the SD500-MIM SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The 5D500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate 11 being UL Wed 762g Lot. Compatible FACPs 5820XL 5820XL-EVS 5808 5700 Ordering Information SD500-AIM Input Module Addressable input module with ivory cover plate. SD500-MIM Input Module Addressable mini input module. D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350231 Rev. F © 2013 Honeywell International Inc D SILENT KNIGHT 5) by Honeywell Model SD500-ARM Addressable Relay Module Place relay applications anywhere on the lntelliKnight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SD500-ARM Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A @ 30 VDC or .6A @ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Features Two sets of Form C contacts. Contacts are rated at 2A @ 30 VDC or .6A @ 120 VAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible through cover plate. Specifications Contact Rating: Form C 2A@3OVDC, .6A@12OVAC Standby Current: .55 mA Alarm Current: .55 mA Ambient 32°F to 120°F Temperature: (0°C to 49°C) Mounting: 4-square electrical box CAUC)) 0 0 0 Model SD500-ARM Listings UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved Compatible Control Panels 5820XL 5820XL-EVS 5808 5700 Model SD500-ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW N / CAUTION REMOVE POWER PRIOR TO SERVICING W~E / 4-7/8" 1" Model SD500-ARM Addressable Relay Module Dimensions DSILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350218 Rev. E subject to change without notice. For more information, contact Silent © 2013 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.siIentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE N7 LISTING No. 7300-0559:0132 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT 5ECUR11Y1985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac©honeywell.com DESIGN: Model 5D500-ARM Relay Module and 5D500-AIM, 5D500-MIM Addressable Input Modules*. Models 5D500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models 5D500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell Model SD505-DUCTR and SD505-DTS-K Detect smoke in air handling systems and prevent re-circulation with Silent Knight's addressable duct smoke detector The SD505-DUCTR addressable duct smoke detector detects smoke and products of combustion present in air moving through an HVAC air handling system. The SD505-DUCTR is a heavy duty metal housing with a pre-installed SD505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. Now there's even more power and flexibility available to the lntelliKnight family of products. For more information on this product or to locate your nearest source, please call 800-328-0103. Model SD505-DUCTR Analog Duct Smoke Detector with Relay Module The Model SD505-DUCTR Addressable Duct Smoke Detector with Relay provides early detection of smoke and products of combustion present in air moving through an HVAC duct to prevent re-circulation of smoke into the air handling system. The SD505- DUCTR is a heavy duty metal housing with a pre-installed SD505-APS Analog Photo Electric Smoke Sensor and relay module. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight FACP. The built-in relay module, in turn, turns off fans, blowers, and other devices. Operation Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7.5") is provided with the detector housing. Intake sampling tubes (ordered separately) are supplied in three standard lengths. Duct mounting is accomplished through a template and 4 sheet metal screws (provided). Features Two-wire connection to SLC Detects and limits spread of smoke LED alarm indication and communication on sensor head Rugged steel backbox with clear plastic cover Installation template included No screens or filters to clean SD505-APS Photoelectric Smoke Detector pre-installed 3 standard tube lengths UL listed, complies with NFPA 72 and 101 CSFM listed MEA Approved 429-92-E, Vol 9 FM Approved Specifications Physical Dimensions: 21/ H x 9" L x 71/" W Weight: 31bs Electrical Operating Voltage: 24 VDC Alarm Relay Contact rating: 10A@24VDC;10A@115VAC; 10A @ 240 VAC Trouble Relay Contact Rating: 2.5A @ 30 VDC Aux. Power Input Current: 20mA Standby, 62 mA Alarm SLC Input Current: 0.5 mA Max. SLS resistance: 50 Ohms SD505-DUCTR SD505-DTS-K Environmental Operating Temp: 32°F to 100°F (0°C to 37°C) Humidity: 10%-85% non-condensing Other Ratings: Air Velocity 300 - 4000 ft/mm Sampling Tubes: SD505-12 2.5ft sampling tube SD505-T5 5ft sampling tube SD505-T10 lOft sampling tube DTS-K connection FACP/5815XL Con nection.j (Style 4) Model SD505-DUCTR and SD505-DTS-K Duct Smoke Detector with Relay and Remote Test Switch Engineering Specifications The air duct smoke detector shall be Silent Knight Model SD505-DUCTR and remote test switch shalFbe SD505-DTS-K. The housing shall contain a Silent Knight model SD505-APS, Photoelectric Smoke Sensor. The duct detector shall be of metal construction. Complete mechanical installation must be able to be performed without removal of the detector cover. Terminal connections shall be screw type using a minimum of #6 screw. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350005 Rev B subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Copyright © 2011 Honeywell International Inc. Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0559:0163 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: Models 5D505-DUCT and 5D505-DUCTR duct smoke detector units, 5D505-DTS-K remote test switch. Each unit consists of a smoke detector head, plastic enclosure, plastic cover, relays, electrical components, and sampling and exhaust tubes. The smoke detector heads are not suitable for use as open area detection. Refer to listee's data sheet for additional, detailed product description and operational considerations. RATING: 120 VAC, 230 VAC, 24 VAC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as duct smoke detector units for use with separately listed compatible fire alarm control units to detect an abnormal amount of smoke density in the*supply air ducts of air conditioning and ventilating system. The air velocity in the duct shall be between 3004000 fpm. NOTE: For duct application only. Not suitable for open area protection. XLF: 3240-0410:0155 06-28-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SD500-PS and SD500-PSDA Addressable Pull-Station IntelIiKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & SD500-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Extremely easy to operate Corrosion-resistant gold-plated contacts. Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby current: .55mA Alarm current: .55mA SD500-PS Ambient Temperature: 32°F to 120°F (0°c to 49°c) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB D SILENT KNIGHT 4.r4!..,, Mounting to Single Gang Electrical Box Mounting to Optional Surface Mount Box SD500-PSDA ... . __F L. Installing SD500-LK SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com FACP Wiring I I1 - !1(2" MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright © 2003 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING. MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0136 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT 5ECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model PS-SKSA and SD500-PS fire alarm pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Updated 08-29-2011 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ON the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT 5499 Distributed KNIGHT Power Module by Honeywell The NAC expander that packs quite a combination punch, a whopping nine amps and built-in synchronization for appliances The 5499 Distributed Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 9 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, AMSECO, Faraday, Gentex®, and Wheelock® - what you need to drive power-hungry components like ADA notification appliances. The 5499's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5499 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5499. Call Silent Knight today for more information at 1-800-328-0103. Description Ground fault detector/indicator The 5499 is a 9 amp notification power Independent trouble relay expander that provides its own AC AC loss delay option shuts off power power connection, battery charging to non-essential high-current circuit, and backup battery for use with accessories like magnetic door holders fire and security controls that have 9-32 Stand alone operation. VDC outputs, such as the Silent Knight Model 5208 Fire Control/Communicator. Lightweight design adds to ease of installation and reduces shipping The 5499 is the cost-effective solution costs for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5499 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 9 amps of notification power Built-in synchronization for appliances from System Sensor®, AMSECO, Faraday, Gentex®, and Wheelock® Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A (Style Z) or 4 Class B (Style Y), or I Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit '2 inputs; 2 Class B (Style B) or 2 Class A (Style D) Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in Connection to Local Fire Control Firepower 5499 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5499. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the Firepower 5499, which provides supervision between the 5499 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5499 signal circuits using the 4.7kw end-of-line resistors provided. Since the 5499 draws very little power from the control, it is possible to connect one Firepower 5499 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. 5499 Supervision The 5499 supervises a variety of functions including: Low AC power. Low battery condition. Earth ground fault. Auxiliary output power limit condition. EOL supervision trouble or power limited condition at an output. when a trouble condition occurs, Firepower 5499 creates a trouble condition on the host control signal circuits to which it is connected. Firepower 5499 still maintains the ability to be activated by the host control. In addition, the 5499 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Model 5499 Distributed Power Module Model 5499 Block Diagram Signal Circuit Output Signal I Signal I Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5499 _______ Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Electrical Specifications Mechanical Specifications Ordering Information AC Input: 120 VAC at 3.OA Dimensions: 12.25" W X 16" H X 3" D 5499 Distributed Power Module Output: 24 VDC at 9 A 30.88 cm W x 40.64 cm H x 7.62 D cm Accessories: Current Operating Temp: SK-SCK Seismic Compliance Kit Standby: 75 mA 32° to 120° F (0° to 49° C) Alarm: 205 mA Humidity: 93% non-condensing max. Auxiliary Power Circuit: 1 Indicator Lights Notification Circuits: 4 AC power on : Green Output Configuration: Battery trouble: Yellow 2 Class A (Style Z) Ground fault: Yellow 4 Class B (Style Y) (1 Class A & 2 Class B) Aux Trouble: Yellow Amps Per Output: 3.0 (9.0 amps total) Output troubles (1-4): Yellow Notification Circuit Output: 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kQ EOL Installation resistor required on each Class B Surface mount circuit Approvals No. of Inputs: 2 NFPA 72 Input Configuration: 2 Class B (Style Y) . UL Listed or 2 Class A (Style Z) CSFM 7300-0559: 123 Input Voltage Range: 9 - 32 VDC MEA 429-92-E Vol. XII OSHPD (CA) OSP-0065-10 Battery charging Capacity: 35.0 AH (see accessories) DSILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are FORM# 350396 Rev F subject to change without notice. For more information, contact Silent © 2013 Honeywell International Inc by Honeywell Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or (203) 484-7161, Fax: (203) 484-7118. For Techinical Support, Please call 800-446-6444. www.silentknight.com Terminal # Description Ratings TB1 I AC (black—hot') 120 VAC 60 Hz, 3A 2 Earth Ground 3 AC (white—neutral") TB2 1 Auxiliary Power (-) 27.4 VDC 3.0 amps 2 Auxiliary Power (+) 3 Notification 4 Output (-) 27.4 VDC 3.0 amps 4 Notification 4 Output (+) 5 Notification 3 Output (-) 27.4 VDC 3.0 amps 6 Notification 3 Output (+) 7 Notification 2 Output (-) 27.4 VDC 3.0 amps 8 Notification 2 Output (+) 9 Notification 1 Output (-) 27.4 VDC 3.0 amps 10 Notification I Output (+) 11 Normally Closed contact 2.5 A @ 250 VAC or 2.5 A @ 30 VDC 12 Common 13 Normally Open contact 14 Input 9-3OVDC 15 Input 2(-) 16 Input 2(+) 17 Input 1 9-3OVDC 18 Input 1 (-) 19 Input 1 (+) Although each output is rated for 3 amps, the total current draw from the outputs and the auxiliary power must not exceed 9 amps. System Overview - Section 3 System Overview Each output circuit is rated at 3 amps. DO NOT OVERLOAD. Overloading a circuit will cause it to shut down (power limit). The circuit will automatically reset once you remove, the overload condition. 3.1 Terminal Descriptions and Electrical Ratings 151253 3 System Overview 3.3 Notification Appliance Circuit Terminals Terminals 3 through 10 are the notification appliance circuit output terminals. Each of the four circuits are rated at 3 amps, although you can only draw a total of 9 amps from the 5499. The 5499 outputs are short-circuit protected (power limited) according to UL 864 standards. Overcurrent indicators are yellow LEDs. The output voltage can vary depending on the load and input voltage. The four power-limited NAC outputs can be configured as follows: Four Class B circuits Two Class A circuits One Class A and two Class B circuits Class B, ANSI temporal-coded circuits AMSECO synchronized outputs Faraday synchronized outputs Gentex synchronized outputs System Sensor synchronized outputs Wheelock synchronization outputs One or both 5499 signal inputs control the NAC outputs, depending on the specific configuration setup. Possible configurations for the 5499 are: For Option: These Inputs: Control These Outputs: As: 1 Input 1 All outputs Class B circuits Input I or Class B ANSI temporal- 2 Outputs 1,2,3, and 4 Input 2 coded circuits Input 1 Outputs I and 2 Class B circuits Input 2 Outputs 3 and 4 Class B circuits Input 1 Output I Class B circuits Input 2 Outputs 2, 3, and 4 Class B circuits 5 Input I Outputs 1-2 and 3-4 Class A circuit pairs Input 1 Outputs 1 and 2 Class B ANSI temporal-coded 6 circuits Input 2 Outputs 3 and 4 Class B circuits Input I Outputs 1-2 Class A circuit pair Input 2 Outputs 3-4 Class A circuit pair Input I Outputs 1-2 Class A circuit pair 8 Input 2 Outputs 3 and 4 Class B circuits Input 1 (Strobe Class A or Class B 9 Control) All outputs Input 2 (Audio Control) Faraday Sync. Output Input 1 (Strobe Class A or Class B 10 Control) All outputs Input 2 (Audio Control) Gentex Sync. Output Input 1 (Strobe Class A or Class B ii Control) All outputs Input 2 (Audio Control) System Sensor Sync. Output Input 1 (Strobe Class A or Class B 12 Control) All outputs Input 2 (Audio Control) Wheelock Sync. Output 151253 5 Installation 4.3 Current Requirements (Standby and Alarm) 4.3.1 Current Drawn From Host Panel Table 4-1 shows the 5499 current draw requirements from the main control panel when the panel's notification appliance circuit is in alarm. The current draw from the main panel when it is supervising the 5499 is the same current draw that would be present when the main panel supervises an ordinary notification appliance circuit. Table 4-1: Alarm Current Drawn From Main Control Panel Panel Voltage Current Alarm Current (for typical voltages) 12 VDC 6.5 mA drawn from main panel's notification 24 VDC One input circuit: 15 mA appliance circuits. Both input circuits: 30 mA 4.3.2 Current Drawn from Battery Batteries used with the 5499 must not exceed 35AH. (33AH max. for FM (Factory Mutual) Installations). Batteries larger than 7 AH will not fit into the 5499 cabinet and must be housed in the RBB Remote Battery Box. See Section 4.7 for battery installation. The following is the maximum current draw from the auxiliary power terminals for standby calculations. These currents assume 24 or 60 hours of standby time, followed by 5 minutes of maximum alarm current. 195 mA for 24 Hour Standby Current 39 mA for 60 Hours of Auxiliary Standby Current The above numbers were calculated assuming the use of 7 AH batteries at 100% of rated capacity. The total current of the 5499, plus all items powered from it, must not exceed 9 A when the panel is in alarm. Use Table 4-2 to ensure that the current does not exceed 9 A and, that the desired amount of standby is possible for the battery intended for use with the 5499. 151253 5499 Distributed Power Module Installation Manual Table 4-2: Battery Calculation Worksheet Device Number of Devices Current per Device Standby Current Alarm Current For each device use this formula: This column X This column = Current per number of devices. 5499 Distributed Power Module (Current draw from battery) 1 Standby: 75 mA 75 mA Alarm: 205 mA 205 mA 5499 Current 75 mA 205 mA Auxiliary Devices Refer to device manual for current ratings. Alarm/Standby mA mA mA Alarm/Standby mA mA mA Alarm/Standby mA mA mA Alarm/Standby mA mA mA Auxiliary Device Current mA mA Notification appliances Refer to device manual for current ratings. Alarm: mA 0 mA mA Alarm: mA 0 mA mA Alarm: mA 0 mA mA Alarm: mA 0 mA mA Notification Appliance Current 0 mA mA Total current ratings of all devices in system (line A + line B + line C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, Chapter 1, 1-5.2.5). 24 Hrs. for NBC, section 3.2.7.8 H Multiply lines E and F. Total standby AH AH Alarm sounding period in hours. In accordance with NBC and ULC. (For example, 5 minutes = .0833 hours.) H Multiply lines E and H. Total alarm AH AH Add lines G and I. Total standby and alarm AH AH Multiply line J by 1.20. (20% extra insurance to meet desired performance) Total ampere-hours required AH 10 151253 A OR Al l] E F G H K Installation 4.4 Connecting the 5499 to a Control Panel Figure 4-2 shows the general layout of the 5499 PC board. This section also provides specific wiring details for accessories. AC Connection Terminals See Section 6 for LED Descriptions _\I I WWI /Er.4th Enabled If Jumper on Pins 2 & 3 )oisatieci if Jumper on Pins I &2 For UL Listed Notification Appliances Figure 4-2 The Model 5499 PC Board Layout Consult the installation manual for specific wiring information for the control panel being used. 151253 11 5499 Distributed Power Module Installation Manual 4.4.1 Common Trouble Relay The 5499 has a Form C trouble relay built into Terminals 11-13. The relay provides a normally open and a normally closed contact, both of which are rated at 2.5A. The trouble relay will deactivate under any trouble condition. A typical application of the trouble relay is to connect the 5499 normally closed (N.C.) contacts in series with the EOL supplied with the fire alarm control panel. This will cause a trouble on the fire alarm control panel when the 5499 opens its trouble contacts. Note: The N. C. contact is the contact that is closed when the 5499 has power and there are no trouble conditions. I t 9 10 Ii 12 13 I 14 15 16 I 17 18 191 _._j I oitri I TRmLE lwpUra I NPUTI I IU. tIk r MOA S C I A 2 C UL listed EOL (supplied with fire panel) Model Must be connected to TTJ5 201 5207 a power limited source Figure 4-3 Trouble Relay Connection Example 12 151253 5499 Distributed Power Module Installation Manual pass the added current load from notification appliances. leTh 1 2 31 I ..1 AUI 444- 4444 444 4 51 IJT4 444 HUL 0UC3 4 Regulated - Supervised Notification Appliance Circuits Power-Limited + - ~2~T + (Class 2) Class A 11 tRUUEI 12 E 13114 1 15 2 16 NPUT NC CON NO.A B 'C + -L+I T _Class A notification 'T I Outputs from FACP In + Out - + / aBpr3to ' wIreB 51 44 / 44 flJcorrecL U" I ioopeig Wong s4nIe wIre tw rereB incorrect For system supervision of terminals 15 and 18, do not use looped wire under the terminals. Break the wire run to provide supervision of connections. Figure 4-4 Class A Supervised Input/Output Connections 4.5.2 Class B Supervised Wiring Figure 4-5 shows how to wire for Class B input and output supervision. Use in/out wiring methods for proper supervision (Refer to the Appendix for notification appliances approved for use with the 5499.) Class B Output Notification Circuits Figure 4-5 shows four, 1.5 A devices wired as Class B. Place a 4.7k ohm EOL resistor (provided) at the end of each circuit to enable supervision when using all outputs as Class B notification appliance circuits. The 4.7k EOLs must be wired to the terminals whether or not you are using all output terminals. 14 151253 Installation Class B Supervised Input Circuits Figure 4-5 shows Class B supervised wiring from a fire alarm control panel to the 5499. Use an EOL resistor as shown to enable notification appliance circuit input supervision. Some panels use EOLs that have a different value from the 4.7k ohm EOL resistor used by the 5499. In this case, the EOL must be UL listed for the fire alarm control panel (not the 5499). Q 1 23 I t S O 10 11 12 13 14 15 10 7 1J 0 101 *02 00T41 L-C~ 1011T21 IOUfI 2110U2LK tNJIN INPI * 113. 1151 II . Hf I 112. III h-Ill I NC (M NO & B C B Regulated Supervised j + NACs () jç [Q ClassBNAC Class B 1 i'1 L1 output from FACP / Model 7628 Model 7628 4.7k EOL 4.7k EOL EOL for the FACP) (must be UL listed Figure 4-5 Class B Supervised Input/Output Connections 4.6 Ground Fault Detection Enable/Disable Jumper In some cases the ground fault detection feature on the 5499 may interfere with the ground fault detection feature of the main control panel in the system. To disable the ground fault detection feature on the 5499, place the jumper block on JI, across Pins I and 2 (see Figure 4-2). 151253 15 5499 Distributed Power Module Installation Manual 4.7 Battery Connection Use two 12 VDC, 7 AH gel cell batteries inside the 5499 cabinet. For batteries larger than 7 AH (not to exceed 35 AH) use the RBB Remote Battery Box. It is recommended that you replace the batteries every five years. The following steps and diagram explain how to connect the batteries. Connect the black wire from the Battery - terminal to the negative (-) side of Battery #2. Connect the jumper wire provided (PN 140694) from the positive (+) side of Bat- tery #2 to the negative side of Battery #1. Connect the red wire from the Battery + terminal to the positive (+) side of battery #1. Jumper (PN 140694) Model 6712 1 (Supervised) Battery 91 1 Battery #2 Figure 4-6 Battery Connection 16 151253 SILENT KNIGHT by Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203-484-7161 Fax: 203-484-7118 www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywelI.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two I2VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Rec 08-17-2006 jw .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Exceder Strobe, Horn Strobe, and Horn Notification Appliances E ATO N Powering Business Worldwide Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12124VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Technical Data TDO01017EN Effective October 2014 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 Ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover I -j 1 73 air Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) HN Series HS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance draw® 12/24VDC on a single appliance Easy to remember model numbers (D Patented Note: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATIDN.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range' All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPNANSI!OSHA RoHS 2 EATON www.eaton.com HN Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24VDC/24FWR Technical Data TDO01017EN Effective October 2014 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 SIC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15)75 HS 8.0-33.0 0.082 0,095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 ' - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24VDC 12 VDC Regulated Voltage Model Range VDC 15 15)75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Regulated Voltage Model Range VDC 99 dB 95 dB HN 16-33.0 0.064 0.044 90 dB 0.022 HNC 16-33.0 0.084 0.044 0.022 FIN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Sync w/ DSM or Wheelock Power Model Strobe Candela Supplies Horn Strobes 12/24 Mounting VDCtD Options HSR 15/1575/30/75/95/110/135/185 X X UMB0 HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75!95/115/150/177 X X UMB® 'Strobes SIR 15/1575/30/75/95/110/135/185 X X UMB® ST\N 15/1575/30/75/95/110/135/185 X X UMB® SIRC 15/30/60/75/95/115/150/177 X X UMB® SIll/C 15/30/60/75/95/115/150/177 , X X UMB® ® 12 VDC models feature 15 & 15/75 settings ® UMB = Universal Mounting Base Model Legend ,HN = Horn Fl = Red ST = Strobe A = Agent Lettering (strobes only) HS = Horn Strobe AL = Alert Lettering (strobes only) C = Ceiling Mount N = No Lettering (strobes only( = White Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: S17N-AL = Strobe, White, Wall Mount, Alert Lettering Example: HSR LU 100 Example: HSWC EATON www.eaton.com 3 Technical Data TDO01017EN HN Series Effective October 2014 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton .com Eaton Cooper Notification 273 Branchport Ave. Long Branch, NJ 07740 CooperNotification.com © 2014 Eaton E All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No. T0001O17EN All other trademarks are property Powering Business Worldwide October 2014 of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional 5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. e *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division a . S ~a~:AIDRE%ACBLE Product Specification Issued: 2005 FIRE ALARM UNSHIELDED, RISER RATED low PART NUMBER: FPL1120 DESCRIPTION: 2/18 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated Conductor Diameter 0.060" Number of Conductors 2 Nom. Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter 0.170", Approximate Cable Weight (lbs .IKft.) 20 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20C 6.43 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 35 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 °C to 60 °C Insulation Colors Red and Black Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D E F ZONE 0 12 3456 789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. b Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 Ch:iia. 2:53 104 a 4 ~%?:I* I DRE 9/A CBL E Product Specification Issued: 2005 FIRE ALARM UNSHIELDED, RISER RATED PART NUMBER: FPL1130 DESCRIPTION: 2/16 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor 16 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated Conductor Diameter 0.070" Number of Conductors 2 Nom. Lay Length 5,0" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter 0.180" Approximate Cable Weight (lbs .1K ft.) 30 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20 4.02 OhmslKft. nom. Capacitance Between Conductors @ I KHz 40 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 to 60 Insulation Colors Red and Black Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D EF ZONE O1 23456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 I WLC ii I1ABLE Product Specification Issued: 2005 FIRE ALARM JACKETED UNSHIELDED, RISER RATED PART NUMBER: FPLII40 DESCRIPTION: 2/14 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cable for Riser Applications. Construction Parameters." Conductor 14 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.015' Insulated Conductor Diameter 0.094" Number of Conductors 2 Nom. Lay Length 5.5" Jacket Material PVC Jacket Thickness 0.025" Nom. Overall Cable Diameter 0.240" Approximate Cable Weight (lbsiKft.) 40 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 2011C 2.52 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 40 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 C to 60 °C Insulation Colors Black and Red Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D EF ZONE 0123456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any a party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 e .dTltt L40Lt lTi: ttC-31-2574ee -31-25746l 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1505:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: JINAN PAC CABLE & WIRE COMPANY248 Avenida Victoria, Unit A, San Clemente, CA 92672 Contact: Christoper "Derek" McMullen (949) 531-8996 Email: derek.mcmullenlgmail.com DESIGN: Power Limited Fire-Protective Signaling Cable, Type FPL, FPLP and *FPLR Refer to listee's data sheet for additional detailed product description and operational considerations. Insulation: PVC, SRPVC with minimum average thickness of 6 mils, minimum at any point at 5 mils; PVC compound Apex 910 with minimum average thickness of 6 mils, minimum at any point at 5 mils, maximum average thickness at 14 mils. *PVC compound Teknor Apex 96-A025A-115 with mm. average thickness 6 mils, mm. at any point 5 mils. Shield (Optional): Aluminum/polyester tape. Core Wrap (Optional): Polyester tape, 2 mils thick max. Jacket: PVC compound Teknor Apex 4128, PVC Compound Apex 910, and *PVC Compound 90-A033A-10 INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Type FPL, FPLP or *FPLR and UL label. APPROVAL: Listed as a power-limited fire protective signaling cable. *Rev. 11-14-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 21 an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division