HomeMy WebLinkAbout5607 PALMER WAY; ; FPC2020-0128; Permit(r,city of Carlsbad Print Date: 12/14/2020 Job Address: 5607 PALMER WAY, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0128 Status: Closed - Finaled Applied: 07/22/2020 Issued: 08/04/2020 Finaled Close Out: 08/17/2020 Inspector: Final Inspection: Project Title: Description: OOLY INC -SPRINKLER MONITORING TI - REPLACEMENT/UPGRADE OF OUTDATED PANEL FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Agua Hedi Cr O'ç ' \\ 1. - OO #', ) PrgerBr.cthrs / q- ( n Breads MkoSfeI - 4gRio6d Empi / - Dyharnis ! CarIsba&wuppIy SOOka OT - .Bewirg supply stote 81 ore nDgo epsc Pic Ies'feIi 40 5104B Honeywell . DsILENT. KMGHT 51OLiB Fire Control Communicator The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-atone unit, it can be used to monitor: Sprinkler systems for waterf low, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone Line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of the six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. FEATURES & BENEFITS UL 864 Listed as an SifiE[isupervised Fuseless overload Reports in SIA and A single, NFPA 72 Central inputs: one Class A protection with most major programmable output Station or Remote input, and five Class B automatic reset communications is provided for alarm Station protected inputs circuitry and fault formats or dialer failed premise unit Downloadable for indicators - Operates on loop start conditions (cannot be FM approved remote programming eliminates the cause phone lines ahead of used for evacuation of most field calls. nov purposes). Can be used as a stand-alone or as a add-on DACT 60 hours of standby power Dual phone line interface Automatic self tests every 24 hours with report sent to central station LII- LJUILUIII9 r DA system. n S 5104B Technical Specifications PHYSICAL Dimensions: 12.25" W x 145" H x 3.0 D (31.1cm W x 36.8 cm H x 7.6cm 0) Weight: 15 lbs. (6.75 kg) Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C'to 49°C) Humidity: 10 to 93°/c relative humidity (non- condensing) ELECTRICAL: Add-on Applications - UL Listed Input: 120VAC 60Hz 40 watts CURRENT: Standby: 50mA 'Alarm: 135m4 STAND ALONE APPLICATIONS Input: I20VAC 60Hz 40 watts Standby: 12V 7 amp hour rechargeable battery 5230 Remote Annunciator: (three maximum per system) Load: 60mA standby, 120mA alarm INDICATOR LIGHTS (LEDS) Power On: (Green) Trouble Silenced: (Yellow) Until Trouble is Cleared/ Flashing: Supervisory Dialer Failure: (Yellow) Telephone Line Fault: (2 Red) Inside Cabinet at Li and L2 Inputs TELEPHONE REQUIREMENTS FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE: 0.OB Type of Jack: RJ31X(2 required) ORDERING INFORMATION 510413: Fire Alarm Communicator. Four-zone digital communication of fire and trouble. ACCESSORIES 5230: Remote Annunciator/Programmer 7181: Fire Zone Converter Module 7860: Telephone Connecting Cord for RJ31X Jack (2 required) 6712:12 volt, TAH rechargeable battery COMMUNICATION FORMATS: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK4/2, Radionics BFSK AGENCY LISTINGS AND APPROVALS UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service FM Approved CSFM Approved MEA For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Honeywell is a registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444 For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com S Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 350349 I Rev FlO5/08 © 2018 Honeywell International Inc. Honeywell DSILENT KNIGHT POwA - FIRE ALARM = ANNUNCIATOR LS23O museum Is sm..,., 5230 Honeywell I DsILENT. KNIGHT 5230 Remote Annunciator The 5230 is a remote annunciator that provides both trouble and alarm annunciation, and a convenient means for programming the 5104, 5128/29, 5204, and the 5207. When the system is normal and receiving AC power, the power LED is on Users identify themselves to the control panel by entering a code on the annunciator. When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other relevant information INSTALLATION Mounts to dual gang electrical box with the rear mounting plate COMPATIBILITY The 5230 is compatible with the following Honeywell Silent Knight FACPs: • 5104: 3 per Communicator 5204: 3 per FACP 5207:7 per FACP 5128/29: Programming only FEATURES & BENEFITS 2-line 16-character LCD display Indicates Trouble, Alarm, Supervisory, and System Status conditions with LEDs and LCD display Each 5230 • Easily set lD using four • Easy quick connect individually dip switches on back option to temporarily supervised by the of unit connect tothe panel FACP for programming 12 to 18 AWG wire with (using PN 130294 up to 1000ftwire runs quick connect cable). from FACP Pi 5230 Technical Specifications For a complete listing of all PHYSICAL ORDERING INFORMATION compliance approvals and certifications, please visit Dimensions: 6.9" W x 4.25" H x 1" D (14.46 cm W x 5230: Remote annunciator/programmer www.silentknight.com. 10.79 cm H x 2.54 cm D) ACCESSORIES Microsoft, Windows, and ENVIRONMENTAL 130294: Quick connect cable the Windows Logo are Operating Temperature: 32°F to 120°F (0°C to registered trademarks or trademarks of 49°C) AGENCY LISTINGS AND APPROVALS Microsoft Corporation. Humidity: 0 to 93% relative humidity (non- NFPA 72 condensing) UL: Listed Silent Knight' and Honeywell are registered CSFM: 7165-0559: fl-. trademarks of Honeywell ELECTRICAL - MEA: 429-92-E International, Inc. Operating Voltage: 12VDC Current This document is not intended to be used for Standby: 6OmA installation purposes. We 'Alarm: 120m4' try to keep our product Maximum wiring distance: 1000Ft information up-to date and accurate We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Silent Knight's 6860 and other products available by visiting www.SilentKnight.com Honeywell Silent Knight 12 Clintonville Road HoneywellNorthford,CT06472-1610 800.328.0103 Doc 3503821 El 03/18 r SILENT* www.honeywell.com © 2018 Honeywell International Inc. J KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION •0_____ OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 00 LISTING SERVICE 'LISTING No. _7166-0559:61 14,' Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Model *5104B Provides automatic, manual and waterfiow service when used as a central station protective premise unit. Intended to monitor various initiating devices and transmit to a central station receiving unit various preprogrammed alarm and trouble signals. Refer to listee's data sheet for detailed product description, electrical rating and operational considerations. *5164B *Six zone control/communicator control unit 5230' Remote annunciator/keypad" INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed control unit for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: Refer to listee's data sheet for required/optional accessories. When required, accessories shall be CSFM listed. *Rev. 08-01-12 gt 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires' 'August 29, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM S $ SENSOR (4$ Photoelectric Smoke Detectors System Sensor Ii" series smoke detectors represent significant advancement in conventional detection. The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. L3) Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® W LISTED €> 0 MEA MSFM AN APPROVED approved approved US 5911 3011445 7272-1653152, 290-01-5 2093 3180932 Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base.The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the il line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection. The j3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire P detectors, This feature verifies the initiating loop wiring by providing LED status indication at each detector. ( Smoke Detector Specifications Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-13, 4W-B) or a combination photoelectric/thermal (Model 2WT-8, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pie-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 85V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current .2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 \ 23 mA @24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2W1-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal InputTerminals 14to22AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal VTim. AlarmT(TIT1 2W-B No 2-wire 130 mA max. limited by control panel 2W1-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20mA@ 12V,23 mA@24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 02 09 System Sensor STEM S 3825 Ohio Avenue. St. Charles, IL 601 74 fr SENSOR Phone: 800-SENSOR2. Fax: 630-377-6495 current product linformaton, Including the latest version of this data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING NO.'7272-1653:O152i Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megari.sissonhoneywell.com DESIGN: Models2W-B 2W1-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2W1-B are 2-wire and model 4W-B and 4W1-13 are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division [I: TELGUARD AMETEK By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new five or sixty minute supervision modes. The TG-7FS LIE-V can also be installed as a backup path and upgraded to sole path at a later date. TG-7FS I CELLULAR ALARM I COMMUNiCATOR LTE-V FOR LTE NETWORKS COMMERCIAL FIRE PRODUCT FEATURES I.. Certified for use on Verizon's LTE network for sunset-free installations. Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LIE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS CDMA transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LIE-V can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each Iandline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. S him TELGUARD TG-7FS LTE-V CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS S AMETEK (ff) F!i_lI1(I!t!Dc!atL_$ LT- Landline tOetionel) Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 • control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 Household burglar alarm systems For the most current product specifications and UL Listings visit www.Telguard.com. SECURITY SIGNAUNG LISTED NFPA® INTERNATIONAl. ELECTRONIC ?L sECuRTY verizon' ASSOCIATION' network certified Executive Strategic Partner Gold S Telguard, a Division of Telular corporation 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA 800.229.2326 1 telguard.com Copyright ©2019 Telguard, a Business Unit of AMETEK, Inc. • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ILISTING No., 7306-1402:0506 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Model TG7LVO02, TG7LVA02, TG7LVF02, *TG7UBLV and JG7 KIT digital cellular communicators, digital cellular radio alarm transmission device used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission device. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *Rev 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listinç Expie. June 30, 2021' Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division 1 c p I FIRE DOCUMENT BOX The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2010 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information mo NFPA Made In U.S.A. -1 0 ISO OOi 411 *% REGISTERED 'L\ COPA MNY V ADA Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 ED0447 LT10505 Rev.B 1/2 No Excuses, Just Solutions! IPSPACE AGE ELECTRONICS, INC. 0 Specifications: The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. ,oran.,sranaammaatarer. a, Property Information Ministers Regained 000ernontetion (SIC-FUN) _______________ I east raiey,at*doal,d.tfl.r.I.Odad.Aiar Oc,Ori,rtp. Certifications and Approvals 2ma,dtaee Fcc, - at at. Fcadal.,s,km.adea,ta aid 16.1 System Installation Contractor fllncae.O.t.ntedidirih..bc,atstkd.S a. aamosacdftrmrow.,thnsdr.,at ga.q,.c,.id.p.atadh,.c,.,.nCpstdea.vc,a,emoer 5 rimynsidcrr*.l an rid.________________________ OM.,st.aa.,.paUSv.dta.,sc,tntcManceidrtec,deadac,a,a.I,a.dea 16.5 Authority Hasteg Jurisdiction r car,atstic,t d.daatl I r.eafl,a.edaaaididncdfonatarcdlcaarnt erdcid.Mc,dcthsud.rans.IetORanes5 vdba.aapat,ac,.sn,eaas,awv.ssm.ssvae r,rmc.w.n. red 1.1.5, .caopwvd.,,,nntccp.ees.Me.ovac,ccsm.aar.c.s.wr.ta acc Psiadded. rccary.t.daranalm,snkthec.carthm.etvr.n.n.lar.ta rid._____________ It 1.mnted,onit.cnaamarlse.n*.bc Equipment information ransrad(..th1.lidothla. In 1 aa~d ____00 a. aowaat Im naCtc&..nRnad -9,-W .ro.Aae.lra a.061.eda.r 1.510044 R- Legend Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. - www.lsae.com . 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00672 Fire Document Box RED SSU00673 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0447 LT10505 Rev.B 2/2 FUNDAMENTALS OF FIRE ALARM SYSTEMS FPc2ô2ô -O FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: OOLY INC. - Address: 5607 PALMER WAY, CARLSBAD CA 92008 Representative of protected property (name/phone): Authority having jurisdiction: CITY OF CARLSBAD - FIRE PREVENTION Address/telephone number: 1635 FARADAY AVE., CARLSBAD CA 92008- 760-602-4665 Organization name /phone Representative name /phone Installer AMERICAN INTEGRATED SYSTEMS - 760.690.3551 JOHN SAMSON - 760.212.9574 Supplier Service organization AMERICAN INTEGRATED SYSTEMS - 760.690.3551 Location of record (as-built) drawings: ON SITE IN DOCUMENT BOX Location of operation and maintenance manuals: ON SITE IN DOCUMENT BOX Location of test reports: ON SITE IN DOCUMENT BOX A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): - Effective date: Expiration date: System Software Operating system (executive) software revision level(s): Site-specific software revision date: Revision completed by: (name) (firm) 1. Type(s) of System or Service _____ NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8— Remote Station Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: _____NFPA 72, Chapter 8— Central Station Prime contractor: GENERAL MONITORING STATIONS 888.467.1119 Central station location: 17951 LYONS CR., HUNTINGTON BEACH CA 92647 (NFPA 72, 1 of 4) FIGURE 4.5.2.1 Record of Completion. 2002 Edition 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio Digital alarm communicator Two-way radio Others CELLULAR Means of transmission of alarms to the public fire service communications center: System location: NFPA 72, Chapter 9—Auxiliary Indicate type of connection: _______ Local energy _______ Shunt -Parallel telephone Location of telephone number for receipt of signals: 2. Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by ZACHARY SAMSON on AUGUST 6, 2020 , includes the devices shown in 5 and 6, and has been in service since AUGUST 6, 2020 NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other (specify): Signed: Date: AUGUST 13, 2020 Organization: AMERI TED SYSTEMS 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached - All operational features and functions of this system were tested by date and found to be operating properly in accordance with the requirements of: 3< NFPA 72, Chapters 1 JJQJ 5 6 7 18JJ 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other (specify): Signed: Organizati•on cAN INTEGRATED SYSTEMS Date: AUGUST 13, 2020 Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: Style: Class: (NFPA 72,2 of 4) FIGURE 4.5.2.1 Continued 2002 Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 5. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: Style: Class:! MANUAL Manual stations Noncoded_________ Transmitters Combination manual fire alarm and guard's tour coded stations Coded_________ Addressable AUTOMATIC Coverage: Complete Partial SPRINKLER MONITORING SYSTEM Selective Nonrequired Smoke detectors 1 Ion Photo Addressable__________ Duct detectors Ion Photo Addressable__________ Heat detectors FT RR FT/RR RC Addressable Sprinkler waterfiow indicators: Transmitters________ Noncoded1 Coded Addressable_________ The alarm verification feature is disabled ________ or enabled , changed from _______ seconds to _______ seconds. Other (list): 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a)___ Coded stations _J_ Noncoded stations Compulsory guard's tour system comprised of ____________ transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided (a)Valve supervisory switches Building temperature points Site water temperature points Site water supply level points Electric fire pump: Fire pump power (I') Fire pump running (g)—Phase reversal Engine-driven fire pump: (h). Selector in auto position Engine or control panel trouble Fire pump running ENGINE-DRIVEN GENERATOR: Selector in auto position Control panel trouble Transfer switches Engine running Other supervisory function(s) (specify): (NFPA 72, 3 of 4) FIGURE 4.5.2.1 Continued 2002 Edition i2-34 NATIONAL FIRE ALARM CODE 7. Annunciator(s) Number: Type: O'\ \Location: k D1) 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6— Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: Style: Class: Types and quantities of notification appliances installed: Bells With Visible Speakers With Visible Horns With Visible Chimes With Visible Other: With Visible Visible appliances without audible: 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: Current rating: Overcurrent protection: Type: Current rating: Location: Secondary (standby): Storage battery: Amp-hour rating: Calculated capacity to drive system, in hours: Engine-driven generator dedicated to fire alarm system:_____________________________________________________________ Location of fuel storage: (C) Emergency system used as backup to primary power supply:___________________________________________________ Emergency system described in NFPA 70, Article 700: 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: FIELD SUPERVISOR AUGUST 13, 2020 (s ed) for Inst ation co Kra or/supplier (title) (date) FIELD SUPERVISOR AUGUST 13, 2020 egfied) for ala service ompany (title) (date) (signed) for central station (title) (date) Upon completio of the syste sati ry test(s) witnessed (if required by the authority having jurisdiction): y'- led) representative of the authority having jurisdiction (title) (date-) (NFPA 72,4 of 4) FIGURE 4.5.2.1 Continued 2002 Edition