HomeMy WebLinkAbout1330 KNOWLES AVE; ; FPR2020-0010; PermitPERMXT REPORT - Print Date: 10/26/2021 Job Address: 1330 KNOWLES AVE, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 1562313600 Track #: Valuation: $317,897.27 Lot #: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: C(qty of Carlsbad Permit No: FPR2020-0010 Applied: 01/30/2020 Issued: 02/13/2020 Finaled Close Out: 06/23/2020 Inspector: Final Inspection: Project : DEV2018-0227 Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Status: Closed - Finaled Single Family Fire Sprinkli Project Title: FERRI RESIDENCE Description: FERRI RESIDENCE -NEW 13D SPRINKLER SYSTEM (28 HEADS) Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 12155 PAINE PL 12155 PAINE PL POWAY, CA 92064-7154 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov FP F,102_0 - D o j c) ,p REPI.4SI'VE IESUREFUL 12155 PAINE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR FERRI RESIDENCE FILE NUMBER: 19-0755.SDF DATE: JANUARY 27, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gprn/ 400 sq.ft. AREA OF APLICATION: M. BEDROOM COVERAGE PER SPRINKLER: 400 sq.ft. NUMBER OF SPRINKLERS: I SPRINKLER TOTAL SPRINKLER WATER FLOW REQUIRED: 20.0 gprn TOTAL WATER REQUIRED (including hose): 25.0 gpm FLOW AND PRESSURE (@ BOR): 20.0 gpm @ 27.4 psi SPRINKLER ORIFICE SIZE: 7/16" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN/ LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT CONTACT: CHRIS (760) 602-2750 WATER PRESSURE INFORMATION: 55 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 1//2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE ONE HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 49.5 48.0 500.0 49.5 25.0 40.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 25.0 G?M TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 20.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) 1 0.0 SOURCE 40.5 25.0 2 1.0 - - - - 32.4 - - - 3 1.0 - - - - 28.4 - - - 4 0.0 - - - - 28.3 - - - 5 2.0 HOSE STREAM 27.4 5.0 6 9.5 - - - - 22.5 - - - 7 10.0 - - - - 20.4 - - - 8 9.5 - - - - 18.0 - - - 8A 9.0 K= 4.90 16.7 20.0 9 14.5 - - - - 16.4 - - - 9A 13.5 - - - - 16.9 - - - bA 13.5 - - - - 16.9 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DAT: 1/9/2020 C:\PROGRAN PILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: PERRI RESIDENCE ONE HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 25.0 0.995 PL 35.00 PF 7.7 1 0.0 SRCE 40.5 (N/A) 10.3 150 FTG TLG PS -0.4 2 1.0 0.0 32.4 0.0 0.169 TL 45.50 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 1.0 0.0 32.4 0.0 4.0 psi, 25.0 gprn 3 1.0 0.0 28.4 0.0 Pipe: 3 25.0 2.050 PL 85.00 PF 0.5 3 1.0 0.0 28.4 0.0 2.4 150 FTG ESL PE 0.4 4 0.0 0.0 28.3 0.0 0.005 TL 108.00 PV Pipe: 4 25.0 1.985 PL 5.00 PP 0.1 4 0.0 0.0 28.3 0.0 2.6 150 FTG E21, PE -0.9 5 2.0 H.S. 27.4 5.0 0.006 TL 19.00 PV Pipe: 5 20.0 1.101 PL 8.00 PP 1.6 5 2.0 H.S. 27.4 5.0 6.7 150 FTG ET2RC PE -3.2 6 9.5 0.0 22.5 0.0 0.068 TL 23.00 PV Pipe: 6 20.0 1.101 PL 7.00 PF 2.0 6 9.5 0.0 22.5 0.0 6.7 150 FTG 3ER PE -0.2 7 10.0 0.0 20.4 0.0 0.068 TL 29.00 PV Pipe: 7 11.8 1.101 PL 47.50 PF 2.6 7 10.0 0.0 20.4 0.0 4.0 150 FTG 6ET5R PE 0.2 8 9.5 0.0 18.0 0.0 0.026 TL 99.50 PV Pipe: 8 20.0 1.101 PL 10.00 PF 1.6 8 9.5 0.0 18.0 0.0 6.7 150 FTG ETR PE 0.2 8A 9.0 4.9 16.7 20.0 0.068 TL 23.00 PV Pipe: 9 -8.2 1.101 PL 15.50 PP 0.6 8 9.5 0.0 18.0 0.0 2.8 150 FTG 452R PE -2.2 9 14.5 0.0 16.4 0.0 0.013 TL 45.50 PV Pipe: 10 0.0 1.101 PL 8.50 PP 0.0 9 14.5 0.0 16.4 0.0 0.0 150 FTG 2ETR PE 0.4 9A 13.5 0.0 16.9 0.0 0.000 TL 28.50 PV Pipe: 11 0.0 1.101 PL 7.00 PP 0.0 9 14.5 0.0 16.4 0.0 0.0 150 FTG ETR PE 0.4 bA 13.5 0.0 16.9 0.0 0.000 TL 20.00 PV Pipe: 12 -8.2 1.101 PL 60.50 PP 2.0 9 14.5 0.0 16.4 0.0 2.8 150 FTC 8E7T PE 1.9 7 10.0 0.0 20.4 0.0 0.013 TL 151.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DAT: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDP JOB TITLE: FERRI RESIDENCE ONE HEAD CALC WATER SUPPLY ANALYSIS Static: 49.50 psi Resid: 48.00 psi Flow: 500.0 gpm LEGEND 50.0 1 1 Available pressure 49.49 psi 8 25.0 gpm G A 40 2) U G E 30.0 P R E 20.0 S U R 10.0 E 2 A Required pressure 40.54 psi @ 25.0 gpm Source Supply Curve System Demand Curve p 0.0 5 i -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DAT': 1/9/2020 C:\PROGRA14 FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE ONE HEAD CALC WATER SUPPLY CURVE 60+ 55+ 500\\\\\\\\ \\\\\\\\\ * <-48.0 psi 8 500 gpm I Flow Test Point 45+ P 40X R I F I S 5 35+ U I R I E I 30+ P I S I I 25+ 20+ 15+ 10+ LEGEND 'V X = Required Water Supply 40.54 psi 8 25.0 gpm 5+ I 0 = Available Water Supply I 49.49 psi 8 25.0 gpm 0++-+---+----+-----+------+--------+--------+ ---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) IEZI'SI'1E • IE8UREUL • tILE 12155 PAINE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR FERRI RESIDENCE FILE NUMBER: I9-0755.SDF DATE: JANUARY 27, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gprn/ 512 sq.ft. AREA OF APLICATION: LIVING ROOM COVERAGE PER SPRINKLER: 256 sq.ft. NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 26.2 gprn TOTAL WATER REQUIRED (including hose): 31.2 gprn FLOW AND PRESSURE (@ BOR): 26,2 gprn @ 23.3 psi SPRINKLER ORIFICE SIZE: 7/16" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT CONTACT: CHRIS (760) 602-2750 WATER PRESSURE INFORMATION: 55 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE 438071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQTD NODE PRESS. PRESS. 8 PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 49.5 48.0 500.0 49.5 31.2 40.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) 1 0.0 SOURCE 40.7 31.2 2 1.0 - - - - 28.8 - - - 3 1.0 - - - - 24.8 - - - 4 0.0 - - - - 24.4 - - - 5 2.0 HOSE STREAM 23.3 5.0 6 9.5 - - - - 17.5 - - - 7 10.0 - - - - 14.0 - - - 8 9.5 - - - - 11.1 - - - 8A 9.0 - - - - 11.3 - - - 9 14.5 - - - - 7.5 - - - 9A 13.5 K= 4.90 7.0 13.0 bA 13.5 K= 4.90 7.3 13.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.2 0.995 PL 35.00 PP 11.5 1 0.0 SRCE 40.7 (N/A) 12.9 150 FTG TLG PE -0.4 2 1.0 0.0 28.8 0.0 0.254 TL 45.50 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 1.0 0.0 28.8 0.0 4.0 psi, 31.2 gpm 3 1.0 0.0 24.8 0.0 Pipe: 3 31.2 2.050 PL 85.00 PP 0.8 3 1.0 0.0 24.8 0.0 3.0 150 FTG E5L PE 0.4 4 0.0 0.0 24.4 0.0 0.008 TL 108.00 PV Pipe: 4 31.2 1.985 PL 5.00 PP 0.2 4 0.0 0.0 24.4 0.0 3.2 150 FTG E2L PE -0.9 5 2.0 H.S. 23.3 5.0 0.009 TL 19.00 PV Pipe: 5 26.2 1.101 PL 8.00 PP 2.6 5 2.0 H.S. 23.3 5.0 8.8 150 FTG ET2RC PE -3.2 6 9.5 0.0 17.5 0.0 0.112 TL 23.00 PV Pipe: 6 26.2 1.101 PL 7.00 PP 3.3 6 9.5 0.0 17.5 0.0 8.8 150 FTG 3ER PE -0.2 7 10.0 0.0 14.0 0.0 0.112 TL 29.00 PV Pipe: 7 13.3 1.101 PL 47.50 PP 3.2 7 10.0 0.0 14.0 0.0 4.5 150 FTG 6ET5R PE 0.2 8 9.5 0.0 11.1 0.0 0.032 TL 99.50 PV Pipe: 8 0.0 1.101 PL 10.00 PP 0.0 8 9.5 0.0 11.1 0.0 0.0 150 FTG ETR PE 0.2 8A 9.0 0.0 11.3 0.0 0.000 TL 23.00 PV Pipe: 9 13.3 1.101 PL 15.50 PP 1.4 8 9.5 0.0 11.1 0.0 4.5 150 FTG 4E2R PE -2.2 9 14.5 0.0 7.5 0.0 0.032 TL 45.50 PV Pipe: 10 13.0 1.101 PL 8.50 PP 0.9 9 14.5 0.0 7.5 0.0 4.4 150 FTG 2ETR PE 0.4 9A 13.5 4.9 7.0 13.0 0.031 TL 28.50 PV Pipe: 11 13.2 1.101 PL 7.00 PP 0.6 9 14.5 0.0 7.5 0.0 4.5 150 FTG ETR PE 0.4 bA 13.5 4.9 7.3 13.2 0.032 TL 20.00 PV Pipe: 12 -13.0 1.101 PL 60.50 PP 4.6 9 14.5 0.0 7.5 0.0 4.4 150 FTG 8E7T PE 1.9 7 10.0 0.0 14.0 0.0 0.030 TL 151.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE TWO HEAD CALC NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.028 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 49.49 psi with a flow of 35.18 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) B T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) B T L C B G A D Ell Tee 1.985 8.00 15.00 3.00 17.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 2.050 8.00 15.00 3.00 17.00 9.00 2.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DAT: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE TWO HEAD CALC PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Pitting Lengths in Feet (in) K T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 LEGEND 1 q Available pressure 49.49 psi 0 31.2 gpm 2 g Required pressure 40.73 psi 0 31.2 gpm Source Supply Curve System Demand Curve 50.0 1 G A 40.2) U G B 30.0 P R E 20.0 S U R 10.0 E p 0.0 5 i -14.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 49.50 psi Resid: 48.00 psi Flow: 500.0 gpm 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 1/9/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\19-0755.SDF JOB TITLE: FERRI RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 60+ 55+ 500\\\\\\\\ I \\\\\\\\\ * <-48.0 psi 8 500 gpm Flow Test Point 45+ x P 40+ R I E I S S 35+ U I R I B I 30+ P I S I 25+ 20+ 15+ 10+ LEGEND X = Required Water Supply 40.73 psi 8 31.2 gpm 5+ 0 = Available Water Supply I 49.49 psi @ 31.2 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) Recessed Concealed Recessed Horizontal Sidewall Pendent PendentlFP Bulletin 014 March 2019 ReIiab1 Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, FIFRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Model Fl FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model Fl FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model Fl FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FR tional sprinkler. The Model Fl FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to afire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid .in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model Fl FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FRS6LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-f actor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler Height g Installation Wrench mm SIN Listings and Approvals Approval Notes US Metric inches mm inches Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 - "Conventional 2.25 57 (Pendent or Upright)" W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH F1FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector! Orientation ___ Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating I 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. I Rating Orange Bulb Red Bulb I Yellow Bulb Green Bulb Blue Bulb F1FR28 Pendent cULus Recessed Pendent cULus I Upright cULus Pendent VdS Recessed Pendent VdS I FIFR42 Pendent cULus Recessed Pendent - - - - cULus I Upright cULus F1FR42LL Pendent cULus, ULH - - Recessed Pendent cULus, ULH FIFRXLH Pendent cULus Recessed Pendent cULus I Upright - cULus F1FR56 Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC Concealed Pendent* cULus I cULus,VdS,EC J cULus Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB VdS EC Fl FR56LL 1 Pendent cULus, ULH Recessed Pendent cULus, ULH Concealed Pendent* cULus, ULH FIFR56 Horizontal Sidewall cULus, FM Recessed Horizontal Sidewall cULus, FM - F1FRS6 Vertical Sidewall (Pen- dent or Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model Fl (Fig. I & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. I & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 FIFR40 Recessed Pendent VdS VdS VdS RA1418 FIFR42 Recessed Pendent cULus cULus cULus RA1413 FIFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 FIFR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, VdS,EC cULus, VdS, EC RA141EC FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 FIFR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] RECESS = 1-5/8"[4 1.3mm] AT MAXIMUM RECESS = 7/8"[22.2mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1- 1/8"[28. 6mm] AT MINIMUM RECESS = 1-5/8"[4 1.3mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS--\\ Fl ESCUTCHEOIj_ 3/4 "[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2 "[12.7mm] ADJUSTMENT T--1 2 1/4W HOLE 014. [57.2mm] I I5/16' 014 [49.2mm] \ / I (1 Fl ESCUTCHEON [3.2mm] AT MINIMUM J l/$ 2 27/32W 0/A. [72.2mm] Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler wfth Model Fl or F2 escutcheon r 1 X 1/2 REDUCER 2 5/8" DIA. [66.7mm] " HOLE IN CEILING / 2 5/16" DIA. [58.7mm] CUP CEILING - f74 I = FACE OF FITTING TO FACE OF CEILING I DIMENSION AT MAX/MUM RECESS 1- 1/2"[38mm] AT MINIMUM RECESS = 1 "[25.4mm] AT MAXIMUM RECESS = 9/16"[14.3mm3 Y."[12. 7mm] AT MINIMUM RECESS = 1 "[25.4mm] ADJUSTMENT Ar 3 114- DIA. [82.6mm] Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon FACE OF F/iT/NC TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAX/MUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAX/MUM RECESS = 3/4 "[79mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE 0/A. [57.2mm] 1" X 1/2" REDUCER Fl ESCUTCHEON (.4 AT IIA V!AI!l14 0E7'CC - JQ"r.4 ()......-... 7 fli WflfltV#IJlVI flj_t...t..._'._? - .1/(.) AT MINIMUM RECESS = 2— 1/16"[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[4 1.3mm] AT MINIMUM RECESS = 2— i/16"[52.4mm] 1 15/16 DIA .4JJoi 4j1 [49.2mm] 111111 I I iiiit1 I lj --.— L_J L_ 2 27/32" DIA. [72.2mm] V (1) 4"-12" [10 1.6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL —' TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON 3/4"[i9mm] ADJUSTMENT F2 ESCUTCHEON 1/2 '[12. 7mm] ADJUSTMENT olx RECESSED HSW WIn OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM1 CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW TF 2 5/16" DIA - CUP ----- 7,,,,,, CEILING -J 1/2" MAX. 1 COVER ADJUSTMENT COVER PLATE - :X/—. I — / ASSEMBLY 5/16" DIA SPRINKLER —2 5/8" DIA. HOLE IN CEILING 4 1 1/2" MAX. FACE OF FITTING FACE OF CEILING //I DIMENSION / - 15/16 ------------ CONCEALED. 1/2" ADJUSTMENT 017FG01A Fig.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model COP cover plate 1" x 1/2" REDUCING TEE OR ELBOW ITIET 2 5/16" DIA - CUP - 2 5/8" 0/A. HOLE /N CEILING 1/2' MAX. I FACE OF F/li/NC TO FACE OF CEILING DIMENSION CEILING 5/16" MAX. " J14 COVER ADJUSTMENT COVER PTE — ASSEMBLY 5/16 0/A. SPRINKLER CONCEALED, 5/16" ADJUSTMENT 017CO2s Fig. 5- Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler j Escutcheon JCover pIate1 -_Chrome Bronze Brass I Chrome Plated I Chrome Plated I White Polyester Coated j White Painted I SpecJ Application Finishes Sprinkler Escutcheon Cover plate" Electroless Nickel PTFE(7) Electroless Nickel PTFE Brass Bright Bright Brass(') Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint26 Black Paint I Off White Off White'26 Off White 1 Satin Chrome Chrome Dull I Chrome Dull I Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector. CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer. Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR40][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sidewall] [Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][lSO 7-R1/2] Sprinkler Temperature Rating: [135°F (570C)][155°F (68°C)] [175°F (79-C)] [200-F (930C)] [286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled Rellabili (800) 431-1588 Sales Offices 0 Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 P/N 9999970300 Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 January 2020 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. Model RFC76 Cii) Model RFC & G5 Cover Plate Sprinkler Model p Nominal K-Factor gpm/psi112 (l/min/bar119 Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA061 1 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA321 1 RFC43 4.3(62) 20 x 20(6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20 (6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector. Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions 2-5/16"(58 mm) Threads Body Cup Tower Ii ..__ 1-3/4(44 mm) +1- 1/4(6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 3/16 (5 mm) 'c. Pin (extended) Deflector (extended) ) Dia. V Ceiling Model G4/G5 Cover Plate 3-5/1& (84 mm Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 NPOEM Page 2 of 8 January 2020 www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Model RFC43 & RFC43LL Sprinkler Components and Dimensions 2-5/16 (58 mm) I Threads Dia. Body Cup Tower 1-3/4"(44 mm) +1- 1/4"(6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 3/16(5mm) I."-.. •-I Pin (extended) Deflector (extended) Model G4/G5 Cover Plate 3-5/16"(84 mm) Dia. \J __....4 Ceiling Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria 11F!TI Minimum Flow and Residual Pressure (1) Max. Coverage Area Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16x16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) -- -- 20x20 21 23.8 (6.1 x6.1) (79) (1.64) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table C above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 NFR=Page 3 of 8 January 2020 www.reliablesprinkIer.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector Bronze Alloy Sprinkler Wrench Model W3 (with wrench-able cap) I Bottom View Model FC (without wrench-able cap) Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions 2-5/16"(58 mm) Threads -' Dia. Body Cup Tower 1-3/4° (44 mm) +1- 1/4(6 mm) " 316° Fusible Link Nominal face of fitting to ceiling Tower Plate W1&(8ia. Deflector (retracted) ,,,, r- / (5 mm) Pin (extended) Deflector (extended) Ceiling Model G4/G5 Cover Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) (2) Max. Coverage Area Ordinary Temperature Intermediate Temperature _________________ Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) - 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 4 of 8 January 2020 0 ROME www.reliablesprinkler.com Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor. Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions 2-5/16'(58 mm) Dia. Threads Body Cup Tower Fusible Link 1-7/8"(48 mm)1+/- 3/8"(9 mm) Deflector (retracted) ••_•• Nominal face of fitting to ceiling Pin (extended) Deflector (extended) Model G4/G5 Cover Plate -' - 3-5/16(84mm) Dia. 3/16'(5 mm) Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure'1 Max. Coverage Area ' Flow Pressure ft. xft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20x20 20 11.9 (6.1 x6.1) (75.7) (0.82) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E above and (2) the flow require d t o achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area list e d . Bulletin 006 IiiIi Page 5 of 8 January 2020 www.reliabIesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model 65 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Bottom View Listings and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions _ 2-5/16° (58 mm) Dia. Threads Body - Cup - Tower - Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) - 1-7/8° (48 mm) +1- 3/8° (9 mm) Nominal face of fitting to ceiling 3/16(5mm) Model G4/G5 Cover Plate 3-5/16° (84 mm) Dia. Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure'1' Max. Coverage Area (Z Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20x20 34 20 (6.1x6.1) (128.7) (1.4) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E ab o v e a n d ( 2 ) t h e f l o w r e q u i r e d t o achieve a minimum design density of 0.1 gpnsq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the nex t l a r g e r m a x . c o v e r a g e a r e a l i s t e d . Bulletin 006 IiIIiIi Page 6 of 8 January 2020 www.reliablesprinkler.com Cover Plate Finishes() Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backsi d e . C o v e r p l a t e s are not listed or approved as corrosion resistant. Installation Dimensions Table Recommended Mm. to Mm. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling(') Ceiling Rating inch (mm) inch (mm) RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL G5 (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 1350F'2 RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 165°F3 RFC49LL (74°C) 135°F2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 165°Ft3 (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fittin g a n d t h r e a d s e a l i n g m e t h o d prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exce e d 1 0 0 ° F ( 3 8 ° C ) . For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not excee d 1 5 0 ° F ( 6 6 0C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January 2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC3O, RFC3OLL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC or G5 Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 Page 8 of 8 January 2020 www.reliablesprinkler.com Z