Loading...
HomeMy WebLinkAbout5404 GRAND PACIFIC DR; ; FPC2017-0143; Permit;a 1 IIli TI C(qty of Carlsbad Print Date: 10/26/2021 Permit No: FPC2017-0143 Job Address: 5404 GRAND PACIFIC DR, CARLSBAD, CA 92008-4723 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2111311600 Track U: Applied: 05/30/2017 Valuation: $249,948.00 Lot U: Issued: 06/20/2017 Occupancy Group: Project U: DEV03006 Finaled Close Out: 07/31/2020 Uof Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: CARLSBAD RANCH PLANNING AREAS Description: SHERATON POOL HOUSE - FIRE ALARM (NEW) Applicant: FPContractor: BERGELECTRIC CORPORATION BERGELECTRIC CORP DONALD CIFUENTES 3182 LIONSHEAD AVE 955 BORRA PL CARLSBAD, CA 92010-4701 ESCONDIDO, CA 92029-2011 (760) 638-2374 (760) 746-1003 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 4 O bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 Addressable Fire Alarm System May 22, 2016 ELECTRICAL SUBCONTRACTOR Bergelectric Corporation 650 Opper Street Escondido, CA 92029 GENERAL CONTRACTOR S ARCHITECT ENGINEER FPC20I7-0143 5404 GRAND PACIFIC DR For Review and Approval Stamping - 650 Opper Street, Escondido, CA 92029 - Tel (760) 746.1003 Fax (760) 741.0918 - License No. C10-85046 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 LIST OF REQUIRED SUBMITTALS Addressable Fire Alarm System Section Para. No. Item Description Submitted Herein Submitted Previously Future Submittal Fire Alarm Control Panel X Intelligent Initiating Devices X Intelligent I/O and Control Devices X Notification Appliances X Operation and Maintenance Manual - FACP X Testing Documents X NFPA 72 Record of Completion Forms X As-built Drawings X Product Data = P. Data Shop Drawings = Dwgs. Test Reports = T. Rpts. DNA = Does not apply to this project bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TABLE OF CONTENTS Addressable Fire Alarm System Section Item Description TAB # Fire Alarm Control Panel I Intelligent Initiating Devices 2 Intelligent I/O and Control Devices 3 Notification Appliances 4 Operation and Maintenance Manual - FACP 5 Testing Documents 6 NFPA 72 Record of Completion Forms As-built Drawings 8 NAME OF SUBCONTRACTOR: Bergelectric Corporation AUTHORIZED SIGNATURE: Donald Cifuentes TITLE OR POSITION: Project Manager DATE: 5/22/2017 0 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB # I Addressable Fire Alarm System Fire Alarm Control Panel 0 EDWARDS Catalog t' Small Building Fire alarm Solutions LIFE SAFETY Ye INCIDENT MANAGEMENT Intelligent Fire Alarm Systems 10643 i0l 000 OWAFD FDNY COA 6227 0 7165-1657: 0244 • Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The 1064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iOl000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZI16-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. iO Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases R-Series remote annunciators SIGA-REL Releasing Modules Fully integrated CO detection using Signature Series detec- tors with or without audible signaling Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour Pagel of 8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 III Application EDWARDS i0 Series life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interlaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with iO Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the i0 Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. iO control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interlace provides common control and 32 LEDs. Programming and remote diagnostics EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, i0 Series systems interlace to a PC running com- patible 0-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the ccrrect communications protocols. The connection can be used to download to the panel from the i0-CU, or upload and view system reports using the iO-CU. Available system reports include: Correlation groups Device details Device maintenance e History Internal status System configuration System status Walk test Dialer CO runtime Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits EDWARDS i0 Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to i0 technology without the expense or disruption of rewiring the en- tire building. i0 control panels also support the ingenious RZl16-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Signals with a difference i0 system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories i0 Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) .0 ModeID1*lD2D3lD4D5*)D6D7lD8D i0i 22.0 15.75 10.25 28.2 2.7 000 I 3.85 t(22.8) (9.8) I 55.8 I (40.0) I (26.0) I (11.1) I (71.6) I (6.8) E(28. 385 15.5 4.5 14.25 10.25 064 I (9.8)9.0) (39.4) (36.2) Add 1-1/2 in. (3.81 cm) to D1 and 05 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. S Page 2of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZ116-2 module Panel Layout 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries System Layout iOl 000 Any combination of two single- or dual Signature loop modules Standard Loop: 250 points (one expansion slot) iOSDC2 Expander, Loop 1 of 2 250 points Up to 125 sensors and 125 modules per loop (one expansion slot) 10-SDC1 Expander Loop: 250 points (one expansion slot) I I iO-SDC2 Expander, Loop 2 of 2: 250 points .Up to 20,000 feet of wiring per loop Four Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each iOl000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. 1064 Iii1L_ 1 Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply Up to eight remote annunciators Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Page 3of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 NO Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit - i01000 i064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 pF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Class B wiring Data Line SLC B Loop Loop Loop card derice d.A. Class A wiring SLC A: Loop rd 050 Line deV Notification appliance circuits (TB2) 01000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications i01000 - 10640 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLP. module Voltage 24 VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz, VAC 60 Hz. 5.oAtotal, 2.5Amax. 3.oAtotal, 2.5Amax. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 0 total, 0.35 pF max EOLR 15K0,1/2 W Synchronization Supported system-wide Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm Trouble Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style Y) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Class A Channel 1 Channel 2 Channel 1 Channel 2 154 Class B wiring Class A wiring Annunciator )CH1(+)IN t CEll (.) IN CH2 (+) IN CH2 (-) IN Annunciator )CHI IN )cl-ii (-) IN CH2 (*-) IN CH2 (-) IN DLR OLR Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. S Page 4 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 Option Cards I EDWARDS 10 Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The 10-SDC1 is a single loop controller card that can be used with the 1064 as a replacement for the standard 64-point loop, or with the 101000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the i01000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications i0-SDC1 iO-SDC2 Device Addresses i01000: one loop, 250 device addresses i064: 64 addresses 101000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 66 C) resistance Max total loop 0.5 iiF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 ko) Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring The SA-ETH card provides a To network connection standard 10/100 Base T Ether- Network cable net network connection for connecting to an intranet, a local network, or the Internet. The card can be used to download configuration programming from the iO-CU to the panel. 1IL 4 The Ethernet card is installed on the plastic assembly and con- nects to the main circuit board Ethernet card via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5 of 8 RZ116-2 Remote Zone Interface Module The RZ116-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI1 6-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZ116-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA' circuit Standby current for 3.9 k EOL (Canada) 5.7 mA' circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kc) (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kfl (U.S.) 22.08 V for 3.9 kC) (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), 101 000, APS DATA SHEET E85001 -0135 Not to be used for installation purposes, Issue 1.1 SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. SA-DACT Phone line 2—. wiring To wall Phone e 1 phone jack Phone cables (supplied <5 I I The dialer phone lines connect to LED ee II nHt11 H H connectors on the dialer's main circuit board. Phone line 1 connects U IIe°O to connector J4 and phone line 2 cliii flD connects to connector Ji. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (031/38)) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBI! CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch 06600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface SA-232 wiring The SA-232 card provides an RS-232 in- GND (black wire) F ____ TXO (white wire) connecting a printer to the control panel FF RXD (red wire) terface with iO panels. It can be used for to print system events. The card also can be used for connecting a computer to download a configuration program from the 0-CU to the control panel. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12 tol8 AWG (075 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with i064 control panels only. iOl 000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. rSACLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16L-iO LED Display Expander (iOl 000 only) The D1 6L-i0 LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-iO LED display expanders can be installed in each iOl 000 panel. (3) (4) LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs is Page 6of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 Specifications i064 i01000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/ioop: 124 Notification appliance 2 Class B (St4e 'Y), Class A (Style Z) optional 4 Class B (Style 16 or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A PiNR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21,9 VDC, special application Note: Fora list of compatible devices, see the i064 and 101000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iOl 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone tine connector: RJ-31 /38X (C31/38)Q Communication formats: Contact ID (SIA DC-35) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kO Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 Ordering Information S B Part Description u01000 Fire Alarm Systems 101000G Four loop system with one 250-point loop installed. 110v, gray door. LIFE SAFETY & INCIDENT MANAGEMENT 101 000G-2 Four loop system with one 250-point loop installed. 230v, gray door. I01000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Contact us... I01000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. Email: edwards.fire@fs.utc.com 1010000-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. Web: Edwards-fire.com I01000GD Four loop system, one 250-point loop installed. 110v, gray door, with dialer. I01000G-F Four loop system, one 250-point loop. iiOv, gray door, LED strips, French Canada. I01000G-PG Four loop system with one 250-point loop installed. 110v, gray door, Portuguese. EDWARDS is a UTC brand 101000G-SP Four loop system with one 250-point loop installed. 110v, gray door, Spanish. 1016 Corporate Park Drive Mebane, NC 27302 01 000R Four loop system with one 250-point loop installed. 110v, red door. I01000R-2 Four loop system with one 250-point loop installed. 230v, red door. © 2016 United Technologies Corporation. I01000RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. All rights reserved. SA-TR1M2 iOi 000 Flush mount trim, black. i064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v, gray door. 1064G-2 One loop system with one 64-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 1064G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. I064GD One loop system, one 64-point loop installed. ilOv, gray door, with dialer. 1064GL One loop system, one 64-point loop installed. 110v, gray door, English Canada. 1064GL-F One loop system, one 64-point loop installed. 110v. gray door, French Canada. 1064G-PG One loop system with one 64-point loop installed. 110v, gray door, Portuguese. 1064G-SP One loop system with one 64-point loop installed. 110v, gray door, Spanish. 1064R One loop system with one 64-point loop installed. 110v, red door. 1064R-2 One boo system with one 64-ooint loon installed. 230v, red door. 1064RD One loop system, one 64-point loop installed. 110v, red door, with dialer. SA-TRIM1 i064 Flush mount trim, black Option Cards iO-SDC1 Expansion module, one 250-device loop. iO-SDC2 Expansion module, two 250-device loops, 500 devices total. For iO1 000 only. RZ116-2 Remote Zone Interlace Module. 16 Class B lDCs, 2 Class B Output. Includes bracket. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. 1064 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For iO1000 only. D16L-iO-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For i01000 only. D8RY-iO-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1000 only. D8RY-iO-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For 101000 only. rAccessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5' - red. SlGA-REL Releasing Module PT-1S System Printer BC-1 Battery Cabinet. 14.0° x 18.25" x 7.25'. Holds two 12V24A batteries. BC-1 R Battery Cabinet - Red. 14.0° x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for i0 series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools 0-CU 10 Series conficiuration and diaqnostics utility. 260097 RS232 cable, 4 conductor. DB9 PC interlace Page 8 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE H :. LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow and sprinkler supervisory service. Models "EST" iO1000G,_iO1000G-2, iO1000GD, iOI000R, iO1000R-2, iO1000RD, iO64G, i064-GD, i064-R,(64-RD) i064G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VS1-G, VSI-GD, VS1-R, VS1-RD, VS1-G-2, VS1-R-2; VS2-G, VS2-GD, VS2-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models "FireworXlKidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1 000, FXI 000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module D16L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XAL127; SLC Loop Driver io-SDC1, V-SLC2-1, FX-SLCI Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pT1.5: System Printer *pT1..p: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately 1ist3d compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. *102416 dc This listing is based upon technical data submitted by the applican. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should iot be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other to Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG-7FS LIE-A CELLULAR ALARM COMMUNICATOR FOR LIE NETWORKS TELGUARD t COMMERCIAL FIRE PRODUCT FEATURES I Certified for use on the AT&T LTE network for long, sunset-free installation. - Meets UL 864 requirements for sole, primary or backup path communications. : Minimizes false alarms by providing dual paths for self-tests. Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being abbe to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. Telguard Portal We Telguard makes adoptingc-e'llular easy with a secFe Inte 451 The straightforward web interface': 1, allows security dealers and central station.ó'quickiy and effiiëti access Telguard based services 2 This advanced tool has mufti-le'7é1 .. user authorization and pro/ide. ) total account management of UL Listed Telguard cellular alarm communicators. 1 éluardCeIlulair Servie ' . . - Telguard Cellular Seird' rovidës AT&1TLTE Pk- wo fof all TeiguarJnitsi ,gqprdsj Comrnunication Centhr is seam IJL . . Jut II,.tl IC .ICI'JOI SJ produàs .nd;thec Telguard Téctwiicl Si a single poirt of ,con! cellular service and Iguard product questions. Adyarked RelibiIity' Features the ability to utilize rultiple cellular technologies to increase availability and reduce false alarms. utomatic self-tests with central station notification ensure the cellular system is operating. ,t vailable relay output for tripping the alarm control panel when a trouble condition occurs. •: CELLULAR ALARM TG-7FS COMMUNICATOR LTE-A FOR LTE NETWORKS TE LG UARD Power E: .a I1S J!±- 60mA (Standby) 250mA Transission). J. Transformer: 12VAC 800iriA p - - - UL listed plug-in. Telguard technology allows full data reporting for unlimited • point-to-point signal details and maximum transmitting power for - Radio Transceiver -- i superior in penetratior. LTE Bands: 2, 4 & IT!:.: 3G Bands: 2 & S. Telguard products are easy to install, economical, and UL Listed. Antenna: 9" dipole with 2di gain 12 ft of cable and universal Accessories mounting bracket. FCC part 15, 22, 24 and 68 compliant. • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of lorw loss, high performance cable. HGD-0: High gain directional antenna. Physical Details- • . . • EXD-0: External antenra. TG-7FS LIE-A: 7.5" H x 115" W x 3.5" D. Shipping Weight: 81bs. Operating Environment: 0°C to +50°C; up to 95% humidity UL Listings (nan-condensing). - Commercial Fire Commerciai Burglary Residential 864 - Control units & 365 • Police Station 985 Housenoid fire accessories for fire connected burglar warning systems alarm systems alarm units and 1023 Household burglar ' •, . systns alarm systems Standard Features ,. " $ 1610 Central station burglar alarm units Full data reporting ;5*., Line security servcies ULC Listings .Automafi s f-test(60imin. &'l) I s' j;Mne . enc, I S545 Canadian household fire warning systems S304 'Canadian commercial burglary alarm systems Two programpabe sUpeiViy C0123 Canadian household burglary alarm systems trip outpUts For the most current product spcci9catnris a id L'L Listings visit www.Telguard.com. Alarm fotmasiSpport fo Sl.2 D, pul Contictj rndem lIe Ono Telephone line moitor built CUs 'L' A!! with Sta Li e Security. LISTED NFPA' //Ih Connecte dárd INTERTIOIL by AT&T / Telguard, a Divisior of Teluiar Corporation • 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 - USA 800-229-2326, Option 5 www.Telguard.com Copyright v2017 Telur Corporation All Rights Reserved t CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL • FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household application and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ACE-Il I FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information Space Age Electronics, Inc. REGISTERED www.Isae.com ly / NFPA COMOANY 800.486.1723 Toll Free MR Made 4U7&A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! SPACE AGE OF ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-E Connector F6o c#.0--W- ft-) Property Information 006609.10053 C.,tiflclti006 and Approvolo 16.1 System InSl8II8tJ0o3 cootoactor 000*6 05 00 053*060610 0 Mtolmoon, Required D0000n,nnt,60n (SIG-FUN) 004.166. 000000.02 00 6 5.061 72 1) 60*.5 S OIVM.00... 6060.0 00300*6* 0036.4109 09.90.31 .50 4800.0.66 000.1*6*0 I 5.0579 *00*0016 1 6 0*10015. 60. 40U0660) 5*0009. 4,03 *6*06*.. 515 0006 000 .009600 SCa,.0,.dS0.d0,.0d06000.069000.otIS0*0I.0i Or I000.0036*006000MtJ..h.6000.60thlfl.04700 II O*6SS2.02050*(S*20*0.*6 46 P.10000020006*,, 1.4*10 0 0 m010S*006000002110000 II 6066, 339*00 70 56006010 1.000.0606* .000060*0103054. 0 .060 646 7.7 16.5 A*thonty Hang J*flSdiCt)ofl) boo 00.6004 . .365*0019 050600*00 *60 60 0* .50 104 600 06 00*2*60 .50 0966616 503.010 00 *601466. 02 .10000.01 900.0 000 .9.051*00. .00005cn*4.300.00.O0.036016.w60401S 0 Equipment lnfonn,060n - Spoaoneso,o*0,Wo. 50 0104*oqfl4.0 0560.161*001564 500.440.1.03 o&Ifl..o00 1T10644 660.7 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED Space Age Electronics, Inc SSU00686 Custom screening with your Logo www.Isae.com fe 800.486.1723 Toll Free Check out our Infinity line eFAD single gang 2 Gig digital storage 508.485.0966 Local solutions (lAM 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7300-0553:0111 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models MBC and BCA battery cabinet enclosures. Minimum thickness .064" cold rolled steel, for batteries with a combined peak voltage of 42.4v. Refert o listees data sheets, installation instrucxtions, and manufacturer's drawings for detailed product description, installation, and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and standards, and in a manner accdeptable to the Authority Having Jurisdiction. MARKING: Listees name, model number, use of product, and UL label. APPROVAL: Listed as a fire alarm equipment battery cabinet enclosure for use with listees fire airm equipment. Refer to listees instalation instruction manual for details. 02-09-16 dc T1 ,° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB #2 Addressable Fire Alarm System Intelligent Initiating Devices 0 EDWARDS Catalog Intelligent Initiating LIFE SAFETY " INCIDENT MANAGEMENT Intelligent Photoelectric A Smoke Detector ($1GA-PS) S853 0 7272-1657: 0126 Overview The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sens- ing element and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards Page lof4 DATA SHEET E850010269 Not to be used for installation purposes. Issue 1 Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to Euro- pean BESA and 1-gang boxes with 60.3 mm fixing centers. L.. J 0.8 (20 mm) 2.0'(51 mm) 4.4' (112 mm) e Tamper-Resist Lever Arm - Break off to disable - (Located on Base) -. - Access Slot for / Tamper-Resist Mechanism CD Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a 'dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity meas- urements which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SIGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electri- cal box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SlGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. SIGA-AB4G SIGA-SB SIGA-16 SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mount- ing base for EDWARDS Signature Series detectors. The SIGA- LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-113, SIGA-1134 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SlGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. S Page 2 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivty of smoke and heat detectors. The table indicates that no single 10 sensing element is suited for all test fires. EDWARDS recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and Test Fire SIGA-PS Photo SIGA-HFS Rate-of- Rise! Fixed Temp. SIGA-PHS Photo Heat 3D SIGA-IPHS Ion/Photo/Heat 4D Open Wood unsuitable optimum very suitable optimum Wood Pyrolysis optimum unsuitable optimum optimum Smouldering Cotton optimum unsuitable optimum optimum Poly Urethane Foam very suitable suitable very suitable optimum n-Heptane very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Relay Detector Base, SIGA-RB, SIGA-RB4 0 Not Used DATA IN/OUT (+) Not Used DATA IN (-) Remote LED (-) Remote LED (+) Not Used DATA OUT C-) Remote LED Max resistance - perwire must not exceed 10 Ohms (-) cii .9' I DATA OUT (-1 DATA IN 1+1 DATA OUT 1+1 From Signature Controller To Next Device or Previous Device - Normally. Normally. DAT, DAT,-, From Signature controller or Previous Device 1 Normally Open 2 DATA IN/OUT (+) 3 Common 4 DATA IN (-) 5 Not Used 6 Normally-Closed 7 DATA OUT(-) CONTACT RATING 1.0 Amp @30 VDC OUT (-) (Pilot Duty) OUT (+) To Next Device Isolator Detector Base, SIGA-113, SIGA-IB4 Term Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN(-) 4 Not Used 5 Not Used 6 DATA OUT (-) 7 Not Used DA1 DA1- , From Signature Controller or Previous Device Audible Detector Base, SIGA-AB4G ©oo@ Volume setting Tone setting Default = High volume \ Default = Temporal pattern Cut for tow volume Cut for steady tone To configure Output volume or tone, cut the circuit board 89 shown. 24 Vdc in From power supply or previous base Data in - From Signature controller or previous device OUT (+) To Next Device OUT (-) 24Vdc out To next base or EOL relay Data out To next Signature device I Page 3 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications 0 Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Environment Air Velocity Range: 0 to 5,000 ft/mm (0 to 2539 m/s); Humidity: 0 to 93% RH, Non-Condensing Operating Temp: 32"F to 120"F (0"C to 49"C); Storage Temp: -47 to 1407 (-20"Cto 60"C) Sensitivity Range ULl/ULC - 0.67% to 3.77% obscuration/foot User Selected Alarm Sensitivity Settings Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.; Normal: 2.5%/ft.; Less Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft. Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Current Quiescent: 45pA © 19 V Alarm: 45i.JA © 19 V Pulse Current: 100 pA (100 msec). During Communication: 9 mA max. Construction & Finish High Impact Engineering Polymer - White Compatible Mounting Bases SIGA-SB Standard Base, SlGA-RB Relay Base, SIGA-113 Isolator Base, SIGA-AB4, SlGA-AB4G Audible Bases LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm. Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm. Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one Device Address Agency Listings UL, ULC, MEA, CSFM, FM UL Listed Spacing 30 ft Ordering Information Catalog Description Ship Wt. Number lbs (kg) SIGA-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SIGA-SB Detector Mounting Base - Standard SlGA-SB4 4-inch Detector Mounting Base c/w SlGA-TS4 Trim Skirt SlGA-RB Detector Mounting Base w/Relay GARB4 4-inch Detector Mounting Base w/Relay, c/w SlGA-TS4 Trim Skirt 0.2 (.09) SlGA-113 Detector Mounting Base w/Fault Isolator SlGA-1134 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base .3(0.15) SlGA-TS4 Trim Skirt (supplied with 4-inch bases) .1 (.04) Page 4 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:0126 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: (Models SlGA-PS and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: 1. Model SIGA-PHS is not intended for use in lieu of a required heat detector. 0 2. Formerly 7272-1591:126 and 7272-1388:186 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 017 - LIFE SAFETY INCIDENT MANAGEMENT Intelligent Heat Detector (SIGA-HRPJ EDWARDS Catalog Intelligent Initiating Devices - romp Mk-V _ \ r200- -Wow awft / - - S853 * Overview The SIGA-HRD is an intelligent fixed temperature/rate-of-rise fire .detector. It monitors the temperature of the surrounding air and analyzes the data from the sensor to determine whether to initiate an alarm. The rate-of-rise heat function quickly detects a fast, flaming fire. The fixed-temperature heat function detects fire when the air temperature near the detector exceeds the alarm point. The SlGA-HRD brings advanced sensing technology to a practi- cal design that increases efficiency, saves installation time, cuts costs, and extends property protection capabilities. Continuous self-diagnostics ensures reliability over the long-haul, while the lat- est thermister technology makes these detectors ideal whereever dependable heat detection is required. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next Generation Heat Sensing Technology 15 OF (9 °C) per minute rate-of-rise alarm point 135 OF (57 °C) fixed temperature alarm point Uses existing wiring Automatic device mapping Sensor Markings Provide Easy Testing Identification Up To 250 Total Signature Devices Per Loop Non-volatile memory Electronic addressing Bicolor (green/red) status LED Standard, relay, fault isolator, and audible mounting bases 50 foot (15.2 meter) spacing I Page 1 o 4 DATA SHEET E85001 -0647 Not to be used for installation purposes. Issue 1 Application The SlGA-HRD combination fixed temperature/rate-of-rise heat detector provides a 15 OF (9 00) per minute rate-of-rise heat sensor for the detection of fast-developing fires, as well as a 135°F (57°C) fixed temperature sensor for slow building-fires. The heat sensor monitors the temperature of the air and determines whether an alarm should be initiated. Compatibility The SIGA-HRD detector is compatible only with the Signature Loop Controller. Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square elec- Self-locking tab trical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. See mounting LED Indicator base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory. Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Accessories Detector mounting bases have wiring terminals that are acces- sible from the 'room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SlGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SlGA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4 inch square box only. SIGA-AB4G/T/LF SIGA-SB SG) SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SlGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SlGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Signature Series sounder bases are designed for use where localized or group alarm signaling is required. SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire- plus-CO mode. SIGA-AB4GT bases provide sounder capability to Signature Series smoke and heat detectors, as well as carbon monox- ide detectors when used with a SIGA-TODR Temporal Pattern Generator. SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detec- tors, as well as carbon monoxide detectors when used with a SlGA-TCDR Temporal Pattern Generator. The SlGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safe- guards with the local fire protection specialist. This detector does not sense fires in areas where heat cannot reach the detector. Heat from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector. This heat detector by itself does not provide life safety protec- tion Use this detector with ionization and/or photoelectric smoke detectors. This detector does not detect oxygen levels, smoke, toxic gases, or flames. Use this device as part of a broad-based life safety program which includes a variety of information sources pertaining to heat and smoke levels, extinguishment systems, visual and audible devices, and other safety mea- sures. Independent studies indicate that heat detectors should only be used when property protection alone is involved. Never rely on heat detectors as the sole means of fire protection. Page 2 of 4 DATA SHEET E85001 -0647 Not to be used for installation purposes. Issue I Isolator Detector Base, SIGA-113, SIGA-I134 This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follow - a short on the line causes all lators to open within 23 msei - at 10 msec intervals, beginning on one side of the Class A . circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. DA1 OUT () OUT (+) To Next Device Term Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN(-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used From Signature Controller or Previous Device Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, SIGA-SB, SIGA-SB4 This is the basic mounting base for EDWARDS Signature Series detectors. The SIGA-LED Re- mote LED is supported by this Base. Term Description 1 Not Used 2 DATA IN/OUT )+) 3 Not Used 4 DATA IN )-) 4 Remote LED (-) 5 Remote LED 6 Not Used 7 DATA OUT Relay Detector Base, SlGA-RB, SlGA-RB4 Normally- NOrrrioI. This base includes a relay. Nor- mally Open or Normally Closed operation is selected during in- stallation. The dry contact is rated for 1 amp(pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SlGA-RB can be DAT operated as a control relay if pro- grammed to do so at the control DATA ti (+) DATA OUT panel. The relay base does not From signature controller To Next Device or Previous Device Term Description support the SIGA-LED Remote 1 Normally Open LED. CONTACT RATING 2 DATA IN/OUT I 1.0 Amp @30 VOC 3 Common I (Pilot Duty) 4 5 6 7 DATA IN (-) I Not Used I Normally-Closed I DATA OUT)-) Remote LED Max resistance per wire + must not exceed 10 Ohms DATA N I-) DATA OUTl-1 DATA IN 1+) DATA OUT 1+) From Signature Controller To Nest Device or Previous Device OUT (.) Audible Sounder Bases, Fire Mode AB4G7 AB4G, AB4G-LF sounder bases SlGA.AB4GT, SIGA-AB4G-LF: StGA.AB4G, SIGA.AB4G-LF: /"eut"\ Output Mode Default = Fire Volume Setting Cut/remove jumper for Default = High Fire plus CO Cut/remove jumper for SIGA-AB4G: low dB Tone Setting DATA- DATA- DATA. Default = Temporal xis, era- our IN IviOUT Cut/remove jumper for Steady ________________ StGA-AB4GT: Not Used 24 Vdc In - II From power supply - 24 Vdc out or previous base + - + To next base or EOL relay Data In -, Data Out From Signature Controller to nest Signature device or previous device + I Page 3 of 4 DATA SHEET E85001 -0647 Not to be used for installation purposes. Issue I Dimensions S LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, INC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 32 pA Vibration level 10 to 35 Hz, with an amplituds of 0.01 in. Rate-of-rise rating 15°F/mm (8°C/mm) Fixed temperature rating 135°F (57.2°C). Actual alarm point 129 to 141°F (53.9 to 60.6°C). Maximum Spacing 50 ft. (15.2 m) centers Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testifire 2000 Operating environment 32 to 100°F (0 to 38°C), 0 to E3% HH, noncondensing Construction High Impact Engineering Foyne Write Storage temperature -4 to 140°F (-20 to 60°C) Agency Listings CAN/ULC-S530, UL 521 Ordering Information Ôatalog : Description - - - Ship Wt. Number lbs (kg) SIGA-HRD Intelligent fixed temperature/Rate-of-rse heat detector 0.4 (0.16) Compatible Bases - SIGA-SB Detector Mounting Base - Standard SlGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SlGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Reia c/w Trim Skirt 0.2 (.09) (SIGA-113 ) Detector Mounting Base w/Fault isoiatcr SIGA 1B4 4-inch Detector Mounting Base w/ Fau t i'olator, c/w Trim Skirt SIGA-LED Remote Alarm LED (not for EN54 SIGA-AB413 Audible (Sounder) Base for Fire Detectois 0.3 (0.15) SIGA-AB4G-LF Low Frequency Audible Sounder) Base for CO and Fire Detectors 0.3 (0.15) SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) SlGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) SlGA-TS Trim Skirt - (optional for non 4-inch basEs) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-RTA - Detector Removal Tool Page 4 of 4 DATA SHEET E85001 -0647 Not to be LSEd for installation purposes. Issue I 10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM is LISTING SERVICE LISTING No. 7270-1657:0333 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-HFD andA-HRQAnalog Addressable Heat Detectors. Model SlGA-HFD is a 135°F fixed temperature heat detector. Model SlGA-HRD is a combination 15°F rate of rise/1 35°F fixed temperature heat detector. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an analog addressable heat detectors for use with listee's Model EST3 (CSFM# 7165-1657-0186), Model EST3X (CSFM# 7165-1657:0306), Model Quickstart (CSFM# 7165-1657:0207), Models i064, i05OO, iO1000 (CSFM# 7165-1657:0244) control units and the following listee's bases; SIGA-SB, -SB4, -RB, -RB4, -IB, -1134 (CSFM# 7300-1657-0120), SlGA-AB4G (CSFM# 7300-1657-0222), SIGA-AB4GT (CSFM# 7300-1657-0307) and S SIGA-AB4G-LF (CSFM# 7300-1657-0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 08-04-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: August 17, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. CATEGORY LISTEE: DESIGN: 7300-1657:0120 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com Detector Bases. Refer to listee's data sheet for detailed product description and operational considerations. Base models are as follow: BASES 5963B, 5964 B/BR 6241 B-002, 6249B-001 6251, 6251 B-001 A, -001, -0C2, -003, -004, 6251 B-100, -200, -R100, -R2C3 and 6251-2 Models 6251 B-001, -002, -003 and -004 suitable for releasing device serv:ce. P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047 -SB4, -RB, -RB4,@) -1134 and -AB4 The -RB series are suitable for releasing device service. I Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. INSTALLATION: In accordance with listee's prnted installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog P Intelligent Initiating H E I LIFE SAFETY INCIDENT MANAGEMENT Manual Pull Stations SIGA-270, SIGA-270P, LSIGA-278) SIGA-278 IJ MEA "? 715016570129 ! Overview S The SIGA-270 and SIGA-278 series Manual Pull Stations are part of EDWARDS's Signature Series system. The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder- coat paint complemented by aluminum colored stripes and mark- ings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool-proof operation. Presignal models (SlGA-270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. EDWARDS's double action single stage SIGA-278 station is a contemporary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked 'LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance SlGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models SlGA-270 models are available for one or two stage alarm S systems. The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the SIGA-270 discourages tampering. Intelligent device with integral microprocessr All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. ADA Compliant Meets ADA requirements for manual pull stations. Electronic Addressing with Non-volatile memo-y Permanently stores programmable address, serial njmber, type of device, and job number. Automatically upia:es historic information including hours of operation, last maintanance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the Icop control- ler regarding its location with respect to other devices on the circuit. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling flashing RED shows alarm state. Designed for high ambient temperature opeation Install in ambient temperatures up to 120 OF (49 °C. Page 1 of 4 DATA SHEET E85001 -0279 Not to be used for installation pJroses. Issue 1 DATA 11(v)> DATA OUT (+1 'IDATA IJ() > .DATA OUT (-) From Signature Controller To Next Device or Previous Device FAI Figure 4. Single Stage Systems REAP VIEW of 270P,270P8 1132 ff1 8765 . S S Ped LED Green LED (Abn/Acflve) 2t C:t C3 Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or "Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1)is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop controller when the station pull lever is operated. The alarm con- dition is latched at the station. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Wiring Notes L Li\ Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. Compatibility Signature Series manual stations are compatible only with ED- WARDS's Signature Loop Controller. PEAR VIEW 01278 Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The SIGA-270 series are opened with a tool; the SIGA-278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFP.A 72 and ULC CAN/ULC 536 standards. Red LED Green LED (Abrm/Acte) (Normal) f DATA 11 (+) >- ' DATA OUT (.) 1 DATA I'4(-) > DATAOUT(.) From Signature Controller Y To Next Device or Previous Device Figure 5. Two Stage Systems Page 2of4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1 Installation Single-stage Signature Series tire alarm manual pull stations mount to North American 21/2 inch (64 mm) deep 1-gang boxes. .Two stage presignal (270P) models require 11/2 inch (38 mm) deep 4-inch square boxes with i-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-1 3; in Canada, use Iberville Model Cl 52-0-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. EDWARDS recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Compatible Electrical Box Cover leleae Screw O Figure 2. SIGA-270, SlGC-270F, SIGC-270B installation Cover Release Figure 3. SIGA-270P, SIGC-270PB installation Page 3 of 4 DATA SHEET' E85001-0279 Not to be used for installation purposes. Issue 1 0 Specifications C • SIGA-270, SIGC- - SIGA-270P, Catalog Number 270F, SIGC-270B SIGC-270PB SIGA-278 Single Action Single Action -Two Double Action Description - One Stage Stage (Presignal) - One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Standby = 250pA Standby = 396pA Standby = 250pA Operating Current Activated = 400pA I Activated = 68OpA Activated = 400pA Diecast Zinc - Red Epoxy Lexan - Red with Construction & Finish with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Temperature: 32"F to 120"F (0"C to 49"C) Storage and Operating Storage Temperature: -4"F to 140"F (-20"C to 60"C) Humidity: 0 to 93% Environment RH On-board Green LED - Flashes when polled LED Operation On-board Red LED - Flashes w hen in alarm Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC (note 1), MEA, CSFM, FM Note: SIGC-270F SIGC-270B and SIGC-270PB are ULC listed only. Suffix "F" indicates French markings. Suffix "B" indicates English/French biling ual markings. Ordering Information Catalog Ship Wt. Number Description -- lbs (kg) SIGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed SlGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed SlGA-270P Two Stage (Presignal) Fire AJarm Station, English Markings - UL/ULC Listed 1(0.5) SIGC- Two Stage (Presignal) Fire Alarm Station, French/English Markings 270PB - ULC Listed SlGA-278 Double Action (One Stage) Fire Alarm Station, English Markings - ULJULC Listed Accessories 32997 GA Key w/Tag - for pre-signal station (CANADA ONLY) 276-K2 GA Key - for pre-signal station (USA ONLY) 276-Ki Station Reset Key, Supplied with all Key Reset Stations -0.1(.05) 27165 12 Glass Rods - for SlGA-270 series (CANADA ONLY) 270-GLR 20 Glass Rods - for SIGA-270 series (USA ONL'T') 276-GLR 20 Glass Rods - for SIGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 1 (0.6) WAIR B LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1 S r L CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7150-1657:0129 Page 1 of I CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-270, SlGA-270P, and i27noncoded, intelligent manual pull stations*. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: Formerly 7150-1591:129 and 7150-1388:194 O 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division to bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 Addressable Fire Alarm System Intelligent I/O and Control Devices SIGA-CTI/2 SIGA-MCT2 zE MEA 7300-1657: 0121 I S3424 I __ EDWARDS Catalog P Intelligent Input-Output LIFE SAFETY INCIDENT MANAGEMENT Input Modules SIGA-CT1, SIGA-CT1 HT, (S1GA-CT2'S1GA-MCT2 Overview Standard Features 0 The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-C12/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SlGA-CTI, SIGA-CTIHT and SlGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 "F to 158 "F (0 "C to 70 "C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SlGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UlO modules. Two- and six-module UlO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. SIGA-CTIHT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page lof4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 uio Motherboard 6-32 Self-tapping screws • Plug in Ulo H Module e 7u - #6 Hat washers Lj Cabinet or electrical enclosure Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SlGA-PRO Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1, SIGA-CTIHT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) LED viewing ports • •'\ I 00 SIGA-MCT2: mount the UIO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SIGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a 'soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SlGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SlGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SlGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 5 DATA IN ' ' DATA OUT 1 DATA IN U DATAOuT(-) From Signature Controller Y to Next Device or Previous Device SlGA-CT2 I I Typical NO InItiotin( Persian I I ULIULCIJ,ted 47ON (01 UL LcLiated /u LI. I 1+1 1+1 o7sccEOL InpCt2 inputS I T AYAVA Typical Wiring Modules will accept #18 AWG (0,75mm2), #16 (1 .0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (075 mm2) #16 AWG (1 00mm2) 4,000 ft (1,219 m) #14 AWG (1 50 mm2) #12 AWG (11 .50 mm2) Typical N.O. Initiating Device Typical N.O. hitioting Device INPUT INPUT 2 AAA Style B (Class B) TB F(MD', UL/ULC Usted S" loB (CleSS B) 471<0 EOL UL/ULC usfed A A A 8 7 6 II UL/ULC Listed 471<0 EOL LLL2SL •471<0 EOL Red LED ____________ Green LED (AI3rm/Active) (NormoB Red LED Green LED (Alorm/Acttsie) 4 3 2 1 (Norma TB1 TB1 f DATA N (+) (' I I DATA OUT (+) 1, DATA IN From Signature Controller Y To Next Device or Previous Device SIGA-CT1, SlGA-CT1 HT NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2 ) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10Vdc@350pA The SIGA-U106R and the SIGA-U102R do not come with TB1 4. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility ,These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. FAI reds uloiRi series ,,rothorbuord I No connections required to, lM C)tOthnrntodulesnnoyrequlns I connections Green IcOlNonanoll Red LCD(Mtioal "N.. le000nneotiocsoniuntpersownss 1reqssired ton HCTS. SIGA-MCT2 Page 3 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NO 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Catalog Number SlGA-CT1HT SIGA-CTI - SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SlGA-MP mounting plates UI02R/6R/6 Motherboard Operating Environment 320F to 158°F (0°C to 70.Q 32'F+ - ° Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC MEA, CSFM Ordering Information Catalog - -- - - - Description Ship Wt. Number lbs (kg) SIGA-CT1 Single Input Module - UL/ULC Listed 0.4(0.15) SIGA-CT1HT Single Input Module High Temperature Operation ULJULC Listed 0.4(0.15) SIGA-CT2 Dual Input Module - UL/ULC Listed 0.4 (0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) rRelated Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) SlGA-Ul02R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions SIGA-UI06R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions SIGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC A Multifunction Fire Cabinet - Red, supports Signature Module 7.0(3.1) - Mounting Plates SIGA-MB4 Transponder Mounting Bracket (allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 EDWARDS Catalog Intelligent Input-Output LIFE SAFETY ' INCIDENT MANAGEMENT Input Modules SIGA-MM1 &(SIGA-WTMD FIRE 1"J P' t'DDJL ;T __FM jHIIIH;lIIIIII h1 cE1 ! 1] S3424 7300-1657: 0121 Standard Features Monitor and waterfiow/tamper applications Includes Alarm with delayed latching (retard) for waterilow applications, Supervisory, and Monitor. Non-volatile memory Permanently stores serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each module transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SlGA-PRO Signature Program/Service Tool. Intelligent module c/w integral microprocessor All decisions are made at the module allowing lower communication speed while substantially improving control panel response time. Less sensitive to line noise and circuit wir- ing properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Designed for high ambient temperature operation Install in ambient temperatures up to 120°F (490C). Overview • The SIGA-MM1 Monitor Module and SlGA-WTM Waterfowl Tamper Module are part of EDWARDS'S Signature Series system. They are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (lDC). The function of the SIGA-MM1 and SlGA-WTM is determined by the factory loaded "personality code". The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The microprocessor in each module provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, Stand-alone Operation and Fast, Stable Communication. Page 1 o 4 DATA SHEET E85001-0297 Not to be used for installation purposes. Issue 1 Application The duty performed by the SIGA-MM1 and SIGA-WTM is de- termined by their factory assigned sub-type code or 'Personality Code. SIGA-WTM NORMALLY-OPEN ALARM - DELAYED LATCH- ING (Factory set Personality Code 2) - Assigned to one circuit. Configures circuit 1 for Class B normally-open Waterf low Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. SIGA-WTM NORMALLY-OPEN ACTIVE - LATCHING (Factory set Personality Code 4) - Assigned to one circuit. Configures circuit 2 for Class B normally open dry contact Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. SlGA-MMI NORMALLY-OPEN ACTIVE - NON-LATCHING (Factory set Personality Code 3) - Assigned to one circuit. Configures circuit 1 for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module.Com- patibility The Signature Series modules are compatible only with ED- WARDS'S Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Testing & Maintenance The module's automatic self-diagnosis identifies when it s defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other perti- nent messages. Single modules may be turned off (de-activated) temporarily, from the control panel. Scheduled maintenance (Reg- ular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Availability of maintenance features is dependent on the Ire alarm system used. Page 2 of 4 Installation The SlGA-MM1 and SIGA-WTM modules mount to North American 2-1/2 inch (64 mm) deep one-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm) wire size. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Personality codes are assigned by the factory. No user configura- tion is required for these modules. DATA SHEET E85001-0297 Not to be used for installation purposes. Issue I 9 0 182 O UL/ULC I Usted Style 8 (Class B) 471(0 EOL AAA Red LED (Alarm/Active) Tel DATA IN (+)) 1. DATA IN From Signature Contror 9 or Previous Device A Typical Wiring The module will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2), #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 i.iF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) #14 AWG (1.50 mm2) 4,000 ft (1219 m) #12 AWG (1.50 mm2) Typical N.O. Waterflow Contact Typical Supervisory Contact Typical N.O. Monitor Contact —fe-- INPUT 1 INPUT 2 _+ A AA Style B (Class B) 4 II UL/ULC Usted . • 471(0 EOL Red LED © © Green LED (Alarm/Active) - (Normal) DATA OUT (+)) { DATA IN(+)) DATA OUT (-) J DATA IN(-) To Next Device From Signature Controller or Previous Device TB2 _. • S A UL/ULC Listed 471(0 EOL Green LED (Normal) DATA OUT W DATA OUT (-) To Next Device Model SIGA-WTM Model SIGA-MMI Notes Maximum 25 ohms resistance per wire. Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2) Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 10 Vdc @ 3501JA. All wiring power limited and supervised. This module will NOT support 2-wire smoke detectors. 9 Page 3 of 4 DATA SHEET E85001-0297 Not to be used for installation purposes. Issue 1 Specifications 9 Catalog Number SIGA-MM1 SIGA-WTM Description Monitor Module Waterf low/Tamper Module Type Code 48 (factory set personality code 3) 49 (factory set personality code 24) Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pA; Activated = 680lJA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction & Finish High Impact Engineering Polymer one-gang front plate - White Storage and Operating Environment Operating Temperature: 32°F to 120"F (aC to 49"C) Storage Temperature: -4F to 140°F (-20°C to 60"C) Humidity: _0 to_93%_RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Agency Listings Use With Signature Loop Controller UL, ULC, CSFM, MEA Mounting North American 2-1/2 inch (64 mm) deep one-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. "W". i . , "e V.11 MW N LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information [Catalog- Ship Wt Number Description lbs (kg) SIGA-MM1 Monitor Module - UL/ULC Listed 0.4(15) SIGA-WIM Waterfiow/lamper Module - UL/ULC Listed 0 rAccessories 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang - MFC A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) SIGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) SlGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SlGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4of4 DATA SHEET E850010297 Not to be used for installation purposes. Issue I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL IL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CCI, SIGA-CC2,_SIGA-CT1, SIGA-CT1HT,(SIGA-CT)SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MMI ,(SR3A-WTM) SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCCI, SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SlGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MP1, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UI02R, SIGA-UI06 and SIGA-U106R motherboards. Model CS-SIGA-CC1 P releasing module. Models SIGA-CC1S and SIGA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CTIHT; Signature Series High Temperature Single Input Module. *SIGA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC . INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division bBergelectric NATIONAL TECH NCLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB #4 Addressable Fire Alarm System Notification Appliances 0 EDWARDS Catalog Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Field Configurable ERT Ceiling Strobes..-.GenesiS Series One or more patents - ! / --mm II I'.zyI FC I IVIEA ( E 7125-1657: 0219 I Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required 'cross" pattern, significantly exceeding UL-1971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 Cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use Page lof4 DATA SHEET E850010557 Not to be used for installation purposes. Issue 1 Application Dimensions Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/" (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. - + To fire7alarm To next appliance, control I end-of-line panel I or return to iI I control + I I I I I I I equipment 6.8"dia. (173mm) (25 MM) O.15m) Light output (effective cd) Percent of UL rating versus angle Percantae of rated output Angle— Horizontal and vertical :utputs reflect the same pattern. Field Configuration Depending on the model, Genes s ceiling speaker-strobes have multi-candela output candela switch (see ordering information). The output / ,,- setting is changed by simply opening the , 7 device and sliding the switch to the desired 1%41 11 setting. The strobe does not have to be removed to change the output setting. / The setting remains visible thrcugh a small lnditor window on the front of the dev e after the cover is closed. WARNING: These devices will not operatE without electrical power. As fires frequently cause power interruptions, we suggt -/ou discuss further safeguards with your local fire protection specialist. 9O '5, S Page 2 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Light output setting, high output models UL or "D" or Light output setting, standard models 751 or "B" 195 or "A" t{95 or or or "B" or "A" Rating r RMS RMS RMS RMS 1 RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Light outpu seting, standard models Light output setting, high output models Typical "15" or "D" "30" or "C" "75" or "B" 1195" or "A" "95" or "D" "115" or "C" 11150" or "B" "177" or "A" Current RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 24 Vdc 63 90 168 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16Vfwr 126 187 368 403 484 570 673 724 20Vfwr 108 156 281 333 380 438 537 604 24Vfwr 97 139 240 270 318 361 434 484 33Vfwr 89 119 197 214 245 269 308 338 Current values are shown in mA. Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for, standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/3035/95 cd (GC-VM) and 95/115/150/177 Cd (GC-VMH) Strobe operating voltage GC-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc RNR. GC-VM series strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control nodule, this strobe, and the control panel to determine allowed wire resistance. SlGA-CC1S, SlGA-MCC1S, SlGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, i064, 0500, Fireshield Plus 3, 5 and 10 zone. Add Gi M for G1-CVM &G1 -HDVM devices only. S Page 3of4 DATA SHEET E850010557 Not to be used for installation purposes. Issue 1 © 2016 United Technologies Corporation. ECS/MNS Appliances (no running manicon on housing) All rights reserved. GCWA-VMA Amber White GCWA-VMC 'Alert" Selectable A, B, C, D 1.8 lb. (0.82 kg.) Clear GCWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA "Ale rt" Amber Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. LIFE SAFETY & INCIDENT MANAGEMENT -. Model 1 Housing I Marking I Lens Strobe Ship Wt. Contact us... Life safety Appliances (c/w running man icon screen printed on housing) Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive GC-VM White None Clear Selectable 15, 30, 75, or 95 cd 1.8 lb. (0.82 kg.) CGCfYMJ White "FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95, 115, 150, or 177 Cd GCF-VMH Mebane, NC 27302 White "FIRE" Units with red, blue or green lenses are available as a special order. Contact customer service for details. Page 4of4 DATA SHEET E850010557 Not to be used for installation purposes. Issue I S 11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0219 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM,(9LVM,)GCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model G1 M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. 0 APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma ø' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division cDwic EDWARDS Catalog Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Field Configurable One or more patents pending. Ceiling Horn -Strobes Genesis Series FC 0 0202 IVIEA ( ( 7300-1657: Overview Standard Features fa Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. S Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or tm plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page lof4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1 / / - ---11_i Application Genesis strobes are UL 1971 -listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used wnere ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required, Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone iused with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoetically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm ccdes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. 0 Polarity alarm c 101 next iliance, I-of-line etum to 2ntr01 Iipment Note: Strobes must have continuous voltage. 10 6.8' dia. "I (173 mm) I Nt (25 mm) - / 0.60"(15 mm) Page 2of4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1 fl Light output - (effective cd) Percent of UL rating versus angle PoCon*ULRng 90' '5- Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High cd Temporal Horn-strobe: High dB Setting • UL 15 cd 30 cd 75 cd Rating RMS RMS RMS 95 cd RMS 95 cd RMS 115 cd RMS 150 cd RMS 177 cd RMS 16 Vdc 147 190 316 372 341 399 506 570 16Vfwr 189 253 417 451 487 578 670 711 GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High cd Temporal Horn-strobe: High dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24 Vdc 80 71 108 101 185 180 212 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 GC-HDVM Temporal Horn-strobe: Low dB Setting GC-HDVMH High cd Temporal Horn-strobe: Low dB Setting Typical 15 cd 36 cd 75 cd 95 cd 95 cd 115 cd 15Ocd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 127 56 155 73 229 118 • 33Vfwr 249 129 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AN calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output High dB Setting UL464 Average Peak Temporal Steady Temporal/ Steady Temporal! Steady 16 Vdc - 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 1 85 1 87.8 1 95.7 1 98.7 Low dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 1 80.9 85.9 1 91.8 1 95.1 Notes 1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3of4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1 Specifications S 'C11JJIAJRI D 8 _______________________ Housing Textured LW stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear) LIFE SAFETY & INCIDENT MANAGEMENT Mounting North-American 4" square box, 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). Contact us... Wire connections Screw terminals: single input for both horn and strobe. #18 to 4fl 2 AWG (0.75 mm2 to 2.5 mm2) wire size Email: edwards.fire@fs.utc.com Web: Edwards-fire.com Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-S526, year 2004 UL EDWARDS isa UTC brand. Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies with UL1 480. All horn-strobes comply with ADA Code of Federal 1016 Corporate Park Drive Mebane, NC 27302 Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered © 2016 United Technologies Corporation. Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) All rights reserved, when used with optional Gi M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM sees temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources G1M-RM, SIGA-CC1S, SlGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal audible pattern 1/2 sec ON,½ sec OFF,½ sec ON,½ sec OFF,½ sec ON,l½sec OFF, then repeat cycle Ordering Information ShiI' Catalog Housing Marking Description Wt. lbs Number Color (kg) GC-HDVM White None Genesis Ceiling/Wall Horn-Strobe (GCF-HDVM White "FIRE" with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red "FIRE" (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115,150cr 177 cd output "Accessories - Gi M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2 SIGA-CC1 S Intelligent Synchronization Output Module (2-gang) 0.5 (023) SIGA-MCC1 S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with FIRE" marking. Page 4 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0202 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST" GI-HVI5, -HV30, -HV60, -HV-75, GI-HOV15, -HOV30, -HOV60, -HOV75, -HOVI10, GIF-HOV15, -HOV30, -HOV60, -HOV75, -HOVIIO, GIRF-HOV15, -HOV30, -HOV60, -HOV75, -HOV110, G1-HDVM, G1R-HDVM, G1F-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, GI-HDV1575, Gi R-HDV1575, GI F-H DVI 575, and G1 RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc I6-33Vdc/Vfwr - Models GI-HDVM, G1R-HDVM, GIF-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, GI R-HDV1575, Gi F-HDV1575, G1RF-HDV1575 Candela: I5cd, 30cd, 60cd, 75cd, 110cd . 15- 95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, G1 R-HDVI 575, GI F-HDV1575, GI RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt ai This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 41, bBergelectric NATIONAL TECH NCLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB #5 Addressable Fire Alarm System C Operation and Maintenance Manual - FACP 0 S bBergelectric NATIONAL TECH NC LOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 Addressable Fire Alarm System Testing Documents 0 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB #7 Addressable Fire Alarm System NFPA 72 Record of Completion Forms bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Pool House Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 Addressable Fire Alarm System As-built Drawings