Loading...
HomeMy WebLinkAbout4575 PARK DR; ; FPR2020-0033; Permit4btyof PERMIT REPORT Carl sbad Print Date: 12/08/2020 Job Address: 4575 PARK DR, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2061924900 Track #: Valuation: $690,729.08 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2020-0033 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 05/14/2020 Issued: 06/01/2020 Finaled Close Out: 12/08/2020 Inspector: Final Inspection: Project Title: Description: PARK SFR - E-REVIEW-PLANS IN ATTACHMENTS -REVISION TO NEW SINGLE FAMILY RESIDENCE 13D SYSTEM (39 HEADS) FPContractor: JOSE BARAJAS P0 BOX 1711 FALLBROOK, CA (760) 419-1629 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 FIRE Plan Review Per Hour - Office Hours $340.00 Total Fees: $711.00 Total Payments To Date: $711.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 I 760-602-85611 I www.carlsbadca.gov THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT r 7K9 020 -003 - - - Fire Protection by Computer Design JB FIRE PROTECTION P.O. BOX 1117 FALLBROOK, CA. 92088 760-419-1269 Job Name : SINGLE FAMILY HOME Building : APN: 206-192-34 Location : PARK DR. CARLSBAD, CA System : CALC AREA 1 Contract Data File : CALC AREA 1 - 20 X 20.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 JB FIRE PROTECTION Page SINGLE FAMILY HOME Date 05/13/2020 HYDRAULIC DESIGN INFORMATION SHEET Name - SINGLE FAMILY HOME Date - 05/13/2020 Location - PARK DR. CARLSBAD, CA Building - APN: 206-192-34 System No. - CALC AREA 1 Contractor - JB FIRE PROTECTION Contract No. - Calculated By - Drawing No. - Construction: ( ) Combustible C ) Non-Combustible Ceiling Height OCCUPANCY - S Type of Calculation: ( )NFPA Y Number of Sprinklers Flowing: S ( )Other T ( )Specific Ruling E 13 Residential (X)l ( )2 Made by ( )NFPA 13R (X)NFPA 13D ( )4 Date M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make TYCO Model TY2234 I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 20.02 Psi Required 43.511 At BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 65 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 1500 Proof Flow Gpm S Elevation - -3 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Roule 111 Windham N.H. USA 03087 Water Supply Curve C JB FIRE PROTECTION Page 2 SINGLE FAMILY HOME Date 05/13/2020 City Water Supply: Demand: Cl - Static Pressure : 58.5 Dl - Elevation : 13.859 C2 - Residual Pressure: 18 D2 - System Flow : 20.024 C2 - Residual Flow : 1500 D2 - System Pressure : 56.435 Hose ( Demand) : 5 D3 - System Demand : 25.024 Safety Margin : 2.044 150 140 130 p120 R0 E10° S90 80 u 70 R 60 E 50D3 40 30 - 20 1 0 I I I I I I . 1.T1 IIIIII I 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary JB FIRE PROTECTION Page 3 SINGLE FAMILY HOME Date 05/13/2020 Fitting Legend Abbrev. Name 1/ % 1 11/4 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N* CPVC9OEllHarvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplingTee - Run I I I I 11 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD JB FIRE PROTECTION Page 4 SINGLE FAMILY HOME Date 05/13/2020 Node Elevation K-Fact Pt Fn Flow Density Area Press No. Actual Actual Rea. i-I1 29.0 4.9 16.7 na 20.02 0.05 400 16.7 H2 29.0 21.62 na H3 29.0 21.62 na H4 19.0 28.19 na H5 19.0 28.19 na Dl 30.0 16.81 na 1 30.0 18.31 na D2 30.0 21.18 na D3 30.0 21.18 na 2 30.0 21.18 na 3 30.0 21.82 na D4 20.0 27.76 na 4 20.0 27.76 na D5 20.0 27.76 na 6 20.0 27.31 na 5 20.0 27.76 na 7 20.0 29.32 na 8 20.0 30.54 na 9 20.0 31.38 na 10 10.0 36.05 na TOR 10.0 36.55 na BOR 2.0 43.51 na 5.0 UG1 -3.0 45.74 na Wi -3.0 47.09 na W2 -3.0 51.23 na 101 -3.0 56.44 na The maximum velocity is 10.32 and it occurs in the pipe between nodes W2 and 101 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams JB FIRE PROTECTION Page 5 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi. 20.02 1.101 N 7.0 1.000 16.700 K Factor 4.90 to 150.0 0.0 7.000 -0.433 Dl 20.02 0.0681 0.0 8.000 0.545 Vel = 6.75 0.0 20.02 16.812 K Factor = 4.88 H2 0.0 1.101 N 7.0 1.000 21.616 to 150.0 0.0 7.000 -0.433 D2 0.0 -0.0001 0.0 8.000 -0.001 Vel = 0 0.0 0.0 21.182 K Factor =0 H3 0.0 1.101 N 7.0 1.000 21.616 to 150.0 0.0 7.000 -0.433 D3 0.0 -0.0001 0.0 8.000 -0.001 Vel = 0 0.0 0.0 21.182 K Factor =0 H4 0.0 1.101 N 7.0 1.000 28.191 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 27.758 K Factor = 0 H5 0.0 1.101 N 7.0 1.000 28.191 to 150.0 0.0 7.000 -0.433 D5 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 27.758 K Factor = 0 Di 20.02 1.101 R 1.0 16.000 16.812 to 150.0 0 5.0 6.000 0.0 1 20.02 0.0682 0.0 22.000 1.501 Vel = 6.75 1 0.0 1.101 4R 4.0 33.083 18.313 to 150.0 0 5.0 9.000 0.0 2 20.02 0.0682 0.0 42.083 2.869 Vel = 6.75 0.0 20.02 21.182 KFactor = 4.35 D2 0.0 1.101 R 1.0 10.000 21.182 to 150.0 0.0 1.000 0.0 D3 0.0 0.0 0.0 11.000 0.0 Vel = 0 D3 0.0 1.101 N 7.0 19.250 21.182 to 150.0 2R 2.0 9.000 0.0 2 0.0 0.0 0.0 28.250 0.0 Vel = 0 2 20.02 1.101 N 7.0 2.333 21.182 to 150.0 0.0 7.000 0.0 3 20.02 0.0683 0.0 9.333 0.637 Vel = 6.75 3 0.0 1.101 N 7.0 10.000 21.819 to 150.0 0.0 7.000 4.331 6 20.02 0.0682 0.0 17.000 1.159 Vel = 6.75 0.0 20.02 27.309 K Factor 3.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams -J JB FIRE PROTECTION Page 6 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D4 0.0 1.101 0 5.0 5.000 27.758 to 150.0 0.0 5.000 0.0 4 0.0 0.0 0.0 10.000 0.0 Vel = 0 4 0.0 1.101 R 1.0 10.917 27.758 to 150.0 0.0 1.000 0.0 D5 0.0 0.0 0.0 11.917 0.0 VeI0 D5 0.0 1.101 R 1.0 5.417 27.758 to 150.0 0.0 1.000 0.0 5 0.0 0.0 0.0 6.417 0.0 Vel = 0 0.0 0.0 27.758 K Factor 0 6 20.02 1.101 0 5.0 1.583 27.309 to 150.0 0.0 5.000 0.0 5 20.02 0.0682 0.0 6.583 0.449 Vel = 6.75 5 0.0 1.101 R 1.0 16.917 27.758 to 150.0 0 5.0 6.000 0.0 7 20.02 0.0682 0.0 22.917 1.563 Vel = 6.75 7 0.0 1.101 R 1.0 11.917 29.321 to 150.0 0 5.0 6.000 0.0 8 20.02 0.0682 0.0 17.917 1.222 Vel = 6.75 8 0.0 1.101 N 7.0 5.250 30.543 to 150.0 0.0 7.000 0.0 9 20.02 0.0682 0.0 12.250 0.835 Vel = 6.75 9 0.0 1.394 0 6.0 10.000 31.378 to 150.0 0.0 6.000 4.331 10 20.02 0.0216 0.0 16.000 0.346 Vel = 4.21 0.0 20.02 36.055 K Factor = 3.33 10 20.02 1.394 2N 16.0 6.750 36.055 to 150.0 0.0 16.000 0.0 TOR 20.02 0.0216 0.0 22.750 0.491 Vel = 4.21 0.0 20.02 36.546 K Factor = 3.31 TOR 20.02 1.394 3R 3.0 9.000 36.546 to 150.0 S 11.11 14.110 6.465 **Fixed Loss =3 BOR 20.02 0.0216 Fsp 0.0 23.110 0.500 Vel = 4.21 BOR 5.00 2.047 E 7.206 5.000 43.511 Qa = 5 to 150.0 0.0 7.206 2.166 UGI 25.02 0.0050 0.0 12.206 0.061 Vel = 2.44 UGI 0.0 2.047 4E 28.824 240.000 45.738 to 150.0 0.0 28.823 0.0 Wi 25.02 0.0050 0.0 268.823 1.351 Vel = 2.44 Wi 0.0 1.025 0.0 1.000 47.089 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 W2 25.02 0.1450 0.0 1.000 0.145 Vel = 9.73 W2 0.0 0.995 T 5.841 25.000 51.234 to 150.0 0.0 5.841 0.0 101 25.02 0.1686 0.0 30.841 5.201 Vel = 10.32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams JB FIRE PROTECTION Page 7 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 25.02 56.435 K Factor = 3.33 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 If O2c -oce~ - - Fire Protection by Computer Design JB FIRE PROTECTION P.O. BOX 1117 FALLBROOK, CA. 92088 760-419-1269 Job Name SINGLE FAMILY HOME Building : APN: 206-192-34 Location : PARK DR. CARLSBAD, CA System : CALC AREA 2 Contract Data File : CALC AREA 2 - 16 X 16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 JB FIRE PROTECTION Page SINGLE FAMILY HOME Date 05/13/2020 HYDRAULIC DESIGN INFORMATION SHEET Name - SINGLE FAMILY HOME Date - 05/13/2020 Location - PARK DR. CARLSBAD, CA Building - APN: 206-192-34 System No. - CALC AREA 2 Contractor - JB FIRE PROTECTION Contract No. - Calculated By - Drawing No. - Construction: ( ) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - S Type of Calculation: ( )NFPA Y Number of Sprinklers Flowing: S ( )Other T ( )Specific Ruling E 13 Residential ( )l (X)2 Made by ( )NFPA 13R (X)NFPA 13D ( )4 Date M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make TYCO Model TY2234 I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 26.30 Psi Required 37.430 At BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 65 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 1500 Proof Flow Gpm S Elevation - -3 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C JB FIRE PROTECTION Page 2 SINGLE FAMILY HOME Date 05/13/2020 City Water Supply: Demand: Cl - Static Pressure : 58.5 Dl - Elevation : 13.859 C2 - Residual Pressure: 18 D2 - System Flow : 26.299 C2 - Residual Flow : 1500 D2 - System Pressure : 53.820 Hose ( Demand) : 5 D3 - System Demand : 31.299 Safety Margin : 4.649 150 140 130 p120 R11° E10° 90 s 80 u 70 -- Cl R6° : D3 E5° 40 30 - 20 Di 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N '1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary JB FIRE PROTECTION Page 3 SINGLE FAMILY HOME Date 05/13/2020 Fitting Legend Abbrev. Name % % 1 1% 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N* CPVC9OEllHarveI-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD JB FIRE PROTECTION Page 4 SINGLE FAMILY HOME Date 05/13/2020 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Hi 29.0 10.81 na H2 29.0 4.9 7.04 na 13.0 H3 29.0 4.9 7.37 na 13.3 H4 19.0 18.86 na H5 19.0 18.86 na Dl 30.0 10.38 na 30.0 10.38 na D2 30.0 6.85 na D3 30.0 7.19 na 2 30.0 10.38 na 3 30.0 11.43 na D4 20.0 18.43 na 4 20.0 18.43 na D5 20.0 18.43 na 6 20.0 17.68 na 5 20.0 18.43 na 7 20.0 21.01 na 8 20.0 23.04 na 9 20.0 24.42 na 10 10.0 29.32 na TOR 10.0 30.14 na BOR 2.0 37.43 na 5.0 UG1 -3.0 39.69 na Wi -3.0 41.73 na W2 -3.0 45.95 na 101 -3.0 53.82 na 0.05 256 7.039 0.05 256 7.0 The maximum velocity is 12.91 and it occurs in the pipe between nodes W2 and 101 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations - Hazen-Williams JB FIRE PROTECTION Page 5 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 0.0 1.101 N 7.0 1.000 10.812 to 150.0 0.0 7.000 -0.433 Di 0.0 -0.0001 0.0 8.000 -0.001 Vel = 0 0.0 0.0 10.378 K Factor 0 H2 13.00 1.101 N 7.0 1.000 7.039 K Factor =4.90 to 150.0 0.0 7.000 -0.433 D2 13.0 0.0306 0.0 8.000 0.245 Vel = 4.38 0.0 13.00 6.851 KFactor= 4.97 H3 13.30 1.101 N 7.0 1.000 7.366 K Factor =4.90 to 150.0 0.0 7.000 -0.433 D3 13.3 0.0320 0.0 8.000 0.256 Vel = 4.48 0.0 13.30 7.189 K Factor = 4.96 H4 0.0 1.101 N 7.0 1.000 18.859 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 18.426 K Factor = 0 H5 0.0 1.101 N 7.0 1.000 18.859 to 150.0 0.0 7.000 -0.433 D5 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 18.426 K Factor = 0 Dl 0.0 1.101 R 1.0 16.000 10.378 to 150.0 0 5.0 6.000 0.0 1 0.0 0.0 0.0 22.000 0.0 Vel = 0 1 0.0 1.101 4R 4.0 33.083 10.378 to 150.0 0 5.0 9.000 0.0 2 0.0 0.0 0.0 42.083 0.0 Vel = 0 0.0 0.0 10.378 K Factor 0 D2 13.00 1.101 R 1.0 10.000 6.851 to 150.0 0.0 1.000 0.0 D3 13.0 0.0307 0.0 11.000 0.338 Vel = 4.38 D3 13.30 1.101 N 7.0 19.250 7.189 to 150.0 2R 2.0 9.000 0.0 2 26.3 0.1129 0.0 28.250 3.189 Vel = 8.86 2 0.0 1.101 N 7.0 2.333 10.378 to 150.0 0.0 7.000 0.0 3 26.3 0.1129 0.0 9.333 1.054 Vel = 8.86 3 0.0 1.101 N 7.0 10.000 11.432 to 150.0 0.0 7.000 4.331 6 26.3 0.1129 0.0 17.000 1.920 Vel = 8.86 0.0 26.30 17.683 KFactor 6.25 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 4ina1 Calculations - Hazen-Williams JB FIRE PROTECTION Page 6 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D4 0.0 1.101 0 5.0 5.000 18.426 to 150.0 0.0 5.000 0.0 4 0.0 0.0 0.0 10.000 0.0 Vel = 0 4 0.0 1.101 R 1.0 10.917 18.426 to 150.0 0.0 1.000 0.0 D5 0.0 0.0 0.0 11.917 0.0 Vel = 0 D5 0.0 1.101 R 1.0 5.417 18.426 to 150.0 0.0 1.000 0.0 5 0.0 0.0 0.0 6.417 0.0 Vel = 0 0.0 0.0 18.426 K Factor = 0 6 26.30 1.101 0 5.0 1.583 17.683 to 150.0 0.0 5.000 0.0 5 26.3 0.1129 0.0 6.583 0.743 Vel = 8.86 5 0.0 1.101 R 1.0 16.917 18.426 to 150.0 0 5.0 6.000 0.0 7 26.3 0.1129 0.0 22.917 2.588 Vel = 8.86 7 0.0 1.101 R 1.0 11.917 21.014 to 150.0 0 5.0 6.000 0.0 8 26.3 0.1129 0.0 17.917 2.023 Vel = 8.86 8 0.0 1.101 N 7.0 5.250 23.037 to 150.0 0.0 7.000 0.0 9 26.3 0.1129 0.0 12.250 1.383 VeI= 8.86 9 0.0 1.394 0 6.0 10.000 24.420 to 150.0 0.0 6.000 4.331 10 26.3 0.0358 0.0 16.000 0.573 Vel = 5.53 0.0 26.30 29.324 K Factor = 4.86 10 26.30 1.394 2N 16.0 6.750 29.324 to 150.0 0.0 16.000 0.0 TOR 26.3 0.0358 0.0 22.750 0.814 Vel = 5.53 0.0 26.30 30.138 K Factor = 4.79 TOR 26.30 1.394 3R 3.0 9.000 30.138 to 150.0 S 11.11 14.110 6.465 **Fixed Loss 3 BOR 26.3 0.0358 Fsp 0.0 23.110 0.827 Vel = 5.53 BOR 5.00 2.047 E 7.206 5.000 37.430 Qa = 5 to 150.0 0.0 7.206 2.166 UGI 31.3 0.0075 0.0 12.206 0.092 Vel = 3.05 UG1 0.0 2.047 4E 28.824 240.000 39.688 to 150.0 0.0 28.823 0.0 Wi 31.3 0.0076 0.0 268.823 2.044 Vel = 3.05 WI 0.0 1.025 0.0 1.000 41.732 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 W2 31.3 0.2200 0.0 i.00C 0.220 Vel = 12.17 W2 0.0 0.995 T 5.841 25.000 45.952 to 150.0 0.0 5.841 0.0 101 31.3 0.2551 0.0 30.841 7.868 Vel = 12.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations - Hazen-Williams JB FIRE PROTECTION Page 7 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 31.30 53.820 KFactor = 4.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design JB FIRE PROTECTION P.O. BOX 1117 FALLBROOK, CA. 92088 760-419-1269 Job Name SINGLE FAMILY HOME Building APN: 206-192-34 Location : PARK DR. CARLSBAD, CA System : CALC AREA 3 Contract Data File : CALC AREA 3 - 16 X 16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 JB FIRE PROTECTION Page SINGLE FAMILY HOME Date 05/13/2020 HYDRAULIC DESIGN INFORMATION SHEET Name - SINGLE FAMILY HOME Date - 05/13/2020 Location - PARK DR. CARLSBAD, CA Building - APN: 206-192-34 System No. - CALC AREA 3 Contractor - JB FIRE PROTECTION Contract No. - Calculated By - Drawing No. - Construction: ( ) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make TYCO Model TY2234 I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 26.59 Psi Required 27.434 At BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 65 R Residual (Psi) - 20 Flow (Gpm) - 1500 S Elevation - -3 P Location: P L Source of Information: Y Pump Data: Rated Cap. @ Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C JB FIRE PROTECTION Page 2 SINGLE FAMILY HOME Date 05/13/2020 City Water Supply: Demand: Cl - Static Pressure : 58.5 Dl - Elevation : 9.528 C2 - Residual Pressure: 18 D2 - System Flow : 26.588 C2 - Residual Flow : 1500 D2 - System Pressure : 44.000 Hose ( Demand) : 5 D3 - System Demand : 31.588 Safety Margin : 14.468 150 140 130 p120 R° E10° s 90 580 u 70 Cl R6° : E 50 40 30 - 20 -- 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N" 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary JB FIRE PROTECTION Page 3 SINGLE FAMILY HOME Date 05/13/2020 Fitting Legend Abbrev. Name 1,4 % 1 1% 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N* CPVC9OEllHarvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplinglee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Hi 29.0 4.36 na H2 29.0 4.36 na H3 29.0 4.36 na H4 19.0 4.9 7.04 na H5 19.0 4.9 7.69 na Di 30.0 3.93 na 30.0 3.93 na D2 30.0 3.93 na D3 30.0 3.93 na 2 30.0 3.93 na 3 30.0 3.93 na D4 20.0 6.85 na 4 20.0 7.16 na D5 20.0 7.52 na 6 20.0 8.26 na 5 20.0 8.26 na 7 20.0 10.9 na 8 20.0 12.97 na 9 20.0 14.38 na 10 10.0 19.29 na TOR 10.0 20.13 na BOR 2.0 27.43 na UG1 -3.0 29.69 na Wi -3.0 31.77 na W2 -3.0 36.0 na 101 -3.0 44.0 na 13.0 0.05 256 7.039 13.59 0.05 256 7.0 5.0 Pressure / Flow Summary - STANDARD JB FIRE PROTECTION Page 4 SINGLE FAMILY HOME Date 05/13/2020 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. The maximum velocity is 13.03 and it occurs in the pipe between nodes W2 and 101 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams JB FIRE PROTECTION Page 5 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn Hi 0.0 1.101 N 7.0 1.000 4.365 to 150.0 0.0 7.000 -0.433 Dl 0.0 0.0 0.0 8.000 0.0 Vel 0 0.0 0.0 3.932 K Factor =0 H2 0.0 1.101 N 7.0 1.000 4.365 to 150.0 0.0 7.000 -0.433 D2 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 3.932 K Factor = 0 H3 0.0 1.101 N 7.0 1.000 4.365 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 3.932 K Factor 0 H4 13.00 1.101 N 7.0 1.000 7.039 K Factor =4.90 to 150.0 0.0 7.000 -0.433 D4 13.0 0.0306 0.0 8.000 0.245 Vel = 4.38 0.0 13.00 6.851 K Factor = 4.97 H5 13.59 1.101 N 7.0 1.000 7.690 K Factor 4.90 to 150.0 0.0 7.000 -0.433 D5 13.59 0.0332 0.0 8.000 0.266 Vel = 4.58 0.0 13.59 7.523 KFactor= 4.95 Dl 0.0 1.101 R 1.0 16.000 3.932 to 150.0 0 5.0 6.000 0.0 1 0.0 0.0 0.0 22.000 0.0 Vel = 0 1 0.0 1.101 4R 4.0 33.083 3.932 to 150.0 0 5.0 9.000 0.0 2 0.0 0.0 0.0 42.083 0.0 Vel = 0 0.0 0.0 3.932 K Factor = 0 D2 0.0 1.101 R 1.0 10.000 3.932 to 150.0 0.0 1.000 0.0 D3 0.0 0.0 0.0 11.000 0.0 Vel = 0 D3 0.0 1.101 N 7.0 19.250 3.932 to 150.0 2R 2.0 9.000 0.0 2 0.0 0.0 0.0 28.250 0.0 Vel = 0 2 0.0 1.101 N 7.0 2.333 3.932 to 150.0 0.0 7.000 0.0 3 0.0 0.0 0.0 9.333 0.0 Vel = 0 3 0.0 1.101 N 7.0 10.000 3.932 to 150.0 0.0 7.000 4.331 6 0.0 0.0 0.0 17.000 0.0 Vel = 0 0.0 0.0 8.263 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 final Calculations - Hazen-Williams / JB FIRE PROTECTION Page 6 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D4 13.00 1.101 0 5.0 5.000 6.851 to 150.0 0.0 5.000 0.0 4 13.0 0.0307 0.0 10.000 0.307 Vel = 4.38 4 0.0 1.101 R 1.0 10.917 7.158 to 150.0 0.0 1.000 0.0 D5 13.0 0.0306 0.0 11.917 0.365 Vel = 4.38 D5 13.59 1.101 R 1.0 5.417 7.523 to 150.0 0.0 1.000 0.0 5 26.59 0.1153 0.0 6.417 0.740 VeI= 8.96 0.0 26.59 8.263 K Factor 9.25 6 0.0 1.101 0 5.0 1.583 8.263 to 150.0 0.0 5.000 0.0 5 0.0 0.0 0.0 6.583 0.0 Vel = 0 5 26.59 1.101 R 1.0 16.917 8.263 to 150.0 0 5.0 6.000 0.0 7 26.59 0.1152 0.0 22.917 2.640 Vel = 8.96 7 0.0 1.101 R 1.0 11.917 10.903 to 150.0 0 5.0 6.000 0.0 8 26.59 0.1153 0.0 17.917 2.065 Vel = 8.96 8 0.0 1.101 N 7.0 5.250 12.968 to 150.0 0.0 7.000 0.0 9 26.59 0.1152 0.0 12.250 1.411 Vel = 8.96 9 0.0 1.394 0 6.0 10.000 14.379 to 150.0 0.0 6.000 4.331 10 26.59 0.0366 0.0 16.000 0.585 Vel = 5.59 0.0 26.59 19.295 K Factor= 6.05 10 26.59 1.394 2N 16.0 6.750 19.295 to 150.0 0.0 16.000 0.0 TOR 26.59 0.0365 0.0 22.750 0.831 Vel = 5.59 0.0 26.59 20.126 K Factor = 5.93 TOR 26.59 1.394 3R 3.0 9.000 20.126 to 150.0 S 11.11 14.110 6.465 **Fixed Loss =3 BOR 26.59 0.0365 Fsp 0.0 23.110 0.843 Vel = 5.59 BOR 5.00 2.047 E 7.206 5.000 27.434 Qa = 5 to 150.0 0.0 7.206 2.166 UG1 31.59 0.0077 0.0 12.206 0.094 Vel = 3.08 UG1 0.0 2.047 4E 28.824 240.000 29.694 to 150.0 0.0 28.823 0.0 Wi 31.59 0.0077 0.0 268.823 2.079 Vel = 3.08 Wi 0.0 1.025 0.0 1.000 31.773 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 W2 31.59 0.2240 0.0 1.000 0.224 Vel = 12.28 W2 0.0 0.995 T 5.841 25.00C 35.997 to 150.0 0.0 5.841 0.0 101 31.59 0.2595 0.0 30.841 8.003 Vel = 13.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams I JB FIRE PROTECTION Page 7 SINGLE FAMILY HOME Date 05/13/2020 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 31.59 44.000 K Factor = 4.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 f2c2O— Oa33 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC — STEEL — COPPER HANGER SIZE - 3/4" thru 3" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - c®tis 203 - EX 4231, EX 2551 FUNCTION - To support horizontal piping - CPVC, Copper or Steel. Hanger in listed mounting positions - Top, Bottom or Side. Also, provides stability on vertical piping. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions on top, bottom or side of building element. Space by pipe type. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC pipe - #905 screw - no pre-drill. 3/4" - 3" Copper pipe - #905 screw - no pre-drill. 3/4" - 3" Steel pipe - 1/4"x 11/2" lag screw - no pre-drill. in STEEL-mm. 18 GA. 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 3" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 3" Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON#905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. *CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 2/08 Side View - For Drawings Below 1(1 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 SIDE MOUNT CPVC - COPPER HANGER SIZE - 3/4" thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - 203 - EX 4231, EX 2551 FUNCTION - Hanger on CPVC and Copper pipe. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions on top or bottom of beam. Space by pipe type SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface on. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. inSTEEL - min. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Hanger - Wood Stud Hanger - Metal Stud Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 513 CPVC — STEEL — COPPER HANGER SIZE - 3/4" thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - 203 - EX 4231, EX 2551 FUNCTION - To support horizontal piping - CPVC, Copper or Steel. Tab up = Hanger. INSTALLATION - Per NFPA 13,13R and 13D on side or top of beam. Space by pipe type. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. 3/4" - 2" Steel pipe - 114"xl 1/2" lag screw - no pre-drill. FEATURES * Offset edge eliminates abrasion. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 OFFSET CPVC HANGER SIZE - 3/4" thru 3"pipe. - MATERIAL - Carbon Steel. FINISH - Mu. Galvanized.. LISTING/APPROVAL - 203 - EX 4231, EX 2551 0 PATENT - No. 6,648,278. FUNCTION - 3/4"-2" Hanger/restrainer for horizontal CPVC, Copper or Steel pipe. Listed hanger/restrainer in all 3 mounting positions, i.e. vertical surface and both top and bottom of horizontal surface. Provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Size 2 %" Hanger for horizontal CPVC pipe. Listed hanger in all 3 mounting positions. i.e. vertical surface and both top and bottom of horizontal surface. Size 3" Hanger for horizontal CPVC pipe in two mounting positions, side and bottom. i.e. vertical surface and bottom of horizontal surface. Stabilizes vertical piping by providing horizontal restraint. INSTALLATION - Per NFPA 13,13R and 13D. Space by pipe type. Install on wood, concrete or steel - See Drawings. Snap over pipe then squeeze strap back allowing pipe to slide freely. Listed When #905 threads are exposed in wood, install #906 backing nut. 3/4 SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13 WOOD - 3/4" - 3" CPVC pipe - #905 screw- no pre-drill. 3/4" - 2" Copper pipe - #905 screw- no pre-drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2" lag screw - no pre-drill. Thru 5/8" gypsum board - 1/4" x 2" lag screw. STEEL - mm. 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener = 5(wt)+2501bs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * 3/4" and 1" pipe size made with common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. #906 A I I +— — Listed Restraint 3/4" thru 2" Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 6/08 Tee Reducing Tee Pipe Manufactured for Viking SupplyNet by Viking Plastics, LLC (Huntsville, Alabama USA.) Size 3/4' Part Number 34P1PE I Bag Qty. 240 ft 1PIPE 150 ft 1-1/4" 114P1PE 105 ft 1-1/2" 112P1PE 75 ft 2P1PE 60 ft 2-1/2" 212P1PE 30 ft 3PIPE 15 ft BlazeMaster® CPVC fittings are manufactured/supplied for Viking SupplyNet by NIBCO, Inc. Standard Fittings Size 3/4" Part Number V5011-007 Box Qty. 250 1" V5011-010 100 1-1/4" V5011-012 25 1-1/2" V5011-015 25 Size 3/4"x3/4x1" Part Number V5011R-102 I I!XS 10 1"x3/4"x3/4" V5011R-125 100 1"x3/4"xl" V5011R-126 10 1"xl"x3/4" V5011R-131 100 1-1/4'xl'04' V5011R-157 5 1-1/4"xl"xl" V5011R-158 25 1-1/4"xl"xl-1/4" V5011 R-159 5 1-1/4"xl-1/4"x314" V5011 R-167 25 1-1/4"x1-1/4"xl" V5011 R-168 25 1-1/4"x1-114"xl-1/2" V5011 R-169 5 1-112"xl-1/4"x314" V5011R-201 5 1-1/2"x1-1/4"x1l" V5011 R-202 S 1-112"xl-1/2"x314" V5011 R-210 25 1-1/2"x1-1/2"x1" V5011 R-211 25 Size I Part NUmber I Box Qty. Tee (continued) V5011-020 2 2-1/2" V5011-025 1 V5011-030 1 Size I •Part iNumber r Reducing Tees (continued) 1-1/2"xl-1/2"xl-114" V5011 R-212 5 1-1/2"x1-1/2"x2" V5011 R-213 5 2"x2"0/4" V5011 R-248 2 2"x2"xl" V5011 R-249 10 2"x2"x1-1/4" V5011 R-250 2 2"x2"xl-112" V5011 R-251 2 2-1/2"x2-1/2"xl" V5011 R-289 1 2-1/2"x2-112"xl-114" V5011 R-290 1 2-1/2"x2-112"xl-112" V5011 R-291 1 2-1/2"x2-1/2"x2" V5011 R-292 1 3"x3"xl-1/2" V5011 R-337 1 3"x3"x2" V5011 R-338 1 3"x3"x2-1/2" V5011 R-339 1 www.vikinggroupinc.com Refer to manufacturer's DESIGN AND INSTALLATiON GUIDE for technical specifications and installation instructions. Standard Fittings continued from Page 1 900 Elbow Q) 450 Elbow ci Size 3/4" Part NUmber IBox V5007-007 S1L1 250 V5007-010 100 1-1/4" V5007-012 25 1-1/2" V5007-015 25 V5007-020 10 Size 3/4" Part NUmber V5006-007 Box Qty. 250 1" V5006-010 100 1-1/4" V5006-012 5 1-1/2" V5006-015 5 Size I Part NLIrnber I Box Qty. 900 Elbow (continued) 2-1/2" V5007-025 1 V5007-030 1 1" x 3/4" V500711-131 100 Size I Part NUmber I Box Qty. 450 Elbow (continued) 2" V5006-020 2 2-1/2" V5006-025 1 3" V5006-030 1 Cross Coupling Size •1Part 3/4" iTr V5035-007 1 I Qty. 10 1" V5035-010 100 1-1/4" V5035-012 5 1-1/2" V5035-015 6 2" V5035-020 4 Size 3/4" Part NUmber V5001-007 Box Qty. 250 1" V5001-010 100 1-1/4" V5001-012 25 1-1/2" V5001-015 25 Box Cross (continued) 2-1/2" V5035-025 4 3" V5035-030 1 1"x1"x3/4"x3/4" V503511-131 10 Size I Part NUmber I Box Qty. Coupling (continued) V5001-020 10 2-1/2" V5001-025 1 V5001-030 1 Reducing Coupling Cj Bushing a Size 1"x3/4" Part NUmber V500111-131 Box Qty. 10 1-1/4" x 1" V500111-168 5 1-1/2" x 3/4' V500111-210 5 1-1/2" x 1" V5001 R-211 5 Size 1" x 3/4" Part NUmber V5018-131 Box Qty. 100 1-1/4"x3/4" V5018-167 25 1-1/4" x 1" V5018-168 25 1-1/2"x 3/4" V5018-210 5 1-1/2" x 1" V5018-211 25 1-1/2"x 1-1/4" V5018-212 25 2" x 3/4" V5018-248 2 2" x 1" V5018-249 2 Size __Box Qty. _____ Reducing Coupling (continued) 1-1/2"x 1-1/4" V5001 R-212 5 2"xl" V5001 R-249 2 2" x 1-1/2" V5001 R-251 2 1w __ Box Qty. Bushing (continued) 2" x 1-1/4" V5018-250 2 2" x 1-1/2" V5018-251 2 2-1/2"x 1-1/4" V5018-290 1 2-1/2"x 1-1/2" V5018-291 1 2-1/2" x 2" V5018-292 1 3" x 2" V5018-338 1 3" x 2-1/2" V5018-339 1 Cap Size 3/4" Part NUmber V5017-007 Box Qty. 250 1" V5017-010 100 1-1/4" V5017-012 5 1-1/2" V5017-015 5 Size •IITNUmber I Box Qty. Cap (continued) V5017-020 2 2-1/2" V5017-025 1 V5017-030 1 www.vikinggroupinc.com Sprinkler Head Adapters BRASTIC Sprinkler -• PaNUmber Box Qty. rt Head Adapter 3/4" x 1/2" V5003SBT-101 100 1" x 1/2" V5003SBT-130 50 * Brass starter thread molded into plastic, virtually eliminating cross-threading. Female Sprinkler Head Size iNUmberBox Qty. Adapter with Metal Thread Insert 3/4" x 1/2" V5003SB1 101 100 1" x 1/2" V5003SBI-130 50 1" x 3/4" V50035B1-131 f 10 Spigot Female Sprinkler Si ze iiNUmber Box Qty. Head Adapter with Metal Thread Insert 3/4" x 1/2" V50032SB1-101 100 (1 1" x 1/2" V500325B1-130 50 Sprinkler Head 90 with Metal Thread Insert Size •i 3/4" x 1/2" Em V500735B1-101 Box Qty. 100 1" x 1/2" V50073SB1-130 50 1" x 3/4" V500735B1-131 10 1-1/4" x 1/2" V500735B1-166 5 Sprinkler Head Tee with Metal Thread Insert Size 1"xl"xl' Pail NUmber V5012SBI-010 Box Qty. 50 3/4"x3/4"xl/2" V5012SB1-101 10 1"xl"xi/2" V50125B1-130 50 1-1/4"xl-1/4"xi/2" V5012SB1-166 5 1-1/2'xl- 112"xl/2" V5012SB1-209 5 2"x2"xl/2" V50125B1-247 2 Size, I Part NUrriber I Box Qty. Sprinkler Head Tee w/Metal Thread Inserts (continued) 1"x3/4"xl/2" V5012R5B1-124 10 1-1/4"xi"xl/2" V5012R5B1-156 5 1- 1/2"xl-1/4"xl/2" V5012R5B1-199 5 2"xl-1/2"xl/2" V5012RSB1-237 2 1 x1/2**x1*** V5014RSBI122* 10 Socket x FIPT x Socket Sprinkler Head Back to Back Cross with Metal Thread Insert Size I •Pail E1TtT Box Qty. lxi "xl/2"xl/2" 1-1/8" V503535B1S-130 1 1x1"x1/2"x1/2" 1-15/16" V503535B1L-130 1 Back to Back Tee with Metal Threads Insert (5 Test Plug Li Size •t NUmber Box Qty. 1/2"xl/2"xl" 1-1/8" V5011335B15-075 48 1/2"x1/2"xl" 1-15/16" V501133SB1L-075 48 Size Part Number Box Qty. - Fr' YL1IZ*J. www.vikinggroupinc.com Transition Fittings Female Adapter with Metal Thread Insert — Ctl Size Part Number I iXs1'i Size I Part NUrnber I Box Qty. 3/4" V5003B1-007 10 Female Adapter w/Metal Thread Inserts (continued) 1" V5003131-010 50 1-1/2" V5003B1-015 5 1-1/4" V5003131-012 5 2" V5003B1-020 2 Spigot Female Adapter Size Paili Number Box Qty. with Metal Thread Insert 3/4" V50032Bl-007 10 1" V50032B1-010 10 C 30 1 Male Adapter with Size inii If1X.1i'j - i Part NUmber I Box Qty. Metal Thread Insert 3/4" V5004B1-007 10 Male Adapter w/Metal Thread Inserts (continued) 1" V500481-010 10 1-1/2" V5004B1-015 5 EIIIi 1-1/4" V5004B1-012 5 2" V5004Bl-020 2 Grooved Coupling Size iitti I Box IS11'A Size Part Number I Box Qty. Adapter 1-1/4" V5001 G-012 30 Grooved Coupling Adapter (continued) 1-1/2" V5001G-015 25 2-1/2" V5001G-025 10 CAII 2" V5001 G-020 15 3" V5001 G-030 8 Standard Union Size 3/4" Part NUrnber V5033E-007 Box Qty. 1 1" V5033E-010 1 1-1/4" V5033E-012 1 1-1/2" V5033E-015 1 Size I Part NUrnber I Box Qty. Standard Union (continued) V5033E-020 1 2-1/2" V5033E-025 1 V5033E-030 1 Accessories Solvent Cement Size Part NUrnber I Box Qty - Quart V5097Q 12 Pint V5097P 12 Dauber Size Part Number I Box Qty Small V5093-SM 100 Large V5093-L Roller 1M- Part NUrnber /A V5097r 24 V2 Size Part Number Box Qty Refer to manufacturer's DESIGN AND INSTALLATION GUIDE for technical specifications and installation instructions. c®us FM > APPRWAD www.vikinggroupinc.com September 2010 ' ..._. ii_.:__ V IKI 1i lid SLICS BlazeMastO CPVC Pipe L Features Sizes Available (Nominal): 3/4" (DN20) through 3" (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) Hazen-Williams C Value: 150 Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) Specifications: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. Pipe meets or exceeds ASTM F442. Certified by NSF International for potable water services. CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved. CPVC PIPE PHYSICAL DATA Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *weight per 15' (4,6 m) length Length Approvals M Part Number Inch DN Inch mm Inch mm Lb. Kg. Feet 3/4" DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cULus,FM, NSF 34P1PE 1" DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PlPE 1 1/4" DN32 1.660 42,164 1.394 35,408 6.27 2,84 15 4.6 114PlPE 11/2" DN40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112P1PE 2" DNSO 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 2 1/2" DN65 2.875 73,000 2.423 61,500 18.86 8,55 15 4.6 212P1PE 3" DN80 3.500 88,900 2.950 74,900 28.01 12,71 15 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *weight per 10' (3,05 m) length Length Approvals M Part Number Inch DN Inch mm Inch mm Lb. Kg. Feet 3/4" DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cULus,FM, NSF 34PIPE10 1" DN25 1.315 33,401 1.101 27,965 2.62 1,19 10 3,05 IPIPElO 1 1/4" DN32 1.660 42,164 1.394 35,408 4.18 1,90 10 3,05 114P1PE10 11/2" DN40 1.900 48,260 1.598 40,589 5.48 2,49 10 3,05 112P1PE10 2" DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2P1PE10 2 1/2" DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 212PIPE10 3" DN80 3.500 88,900 2.950 74,900 18.67 8,47 10 3,05 3PlPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. Blazemaster° is a registered trademark of Lubrizol. - Specifications subject to change without notice *Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. Trusted above aII' NIKINGI ®R Viking Plastics BlazeMaster® CPVC Pipe CPVC Pipe Product Specifications Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. Residential occupancies up to and including four stories in height as defined by NFPA 13R. Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the follow- ing enhanced listings and approvals: According to UL Listing Can be flush at return air plenums Exposed system risers NFPA 13D, 13R Exposed basement NFPA 13D (solid wood joist) Extended coverage (exposed) 20' spacing on pendent in lieu of 15' 18' spacing on sidewall in lieu of 14' Use with combustible concealed sprinklers Tyco attic sprinkler head (to protect the floor below) Tyco attic sprinkler head with wet system piping (feed main and ridge installation) New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. cvc pipe meets all applicable standards for pressure rated applica- tion as required in ANSI-NSF Standard 14 and complies with ANSI-NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All cvc fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @65.5°C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer's DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. Exposed sidewall sprinkler listing for exposed pipe & fittings 24' extended coverage sidewall sprinkler, 12" drop, 155°F sprinkler head 18' extended coverage sidewall sprinkler, 12" drop, 165°F sprinkler head 16' extended coverage sidewall sprinkler, 12" drop, 175°F sprinkler head 14' standard coverage sidewall sprinkler, 12" drop, 200°F sprinkler head Factory Mutual Approved* Factory Mutual Approval exposed Factory Mutual Approval above drop-in ceilings Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All cvc pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer's DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. cvc pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer's installation instructions provided with the pipe. The manufacturer's installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Trusted above al IT" N I KI NGI® 2o2ô -0033 tqco W Contacts I: Series TYFRB - 28,42,5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The TY-FRB Recessed Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following Recessed Escutcheons: A two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. A two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356. Sprinkler Guards are detailed in Technical Data Sheet TFP780. NOTICE The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having J urisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. JULY 2018 Sprinkler Identification Number (SIN) TY1131 . . . Upright 2.8K, 1/2 in. NPT TY1231.. Pendent 2.8K, 1/2 in. NPT TY2131 ... Upright 4.2K, 1/2 in. NPT TY2231.. Pendent 4.2K, 1/2 in. NPT TY3131 ... Upright 5.6K, 1/2 in. NPT TY3231.. Pendent 5.6K, 1/2 in. NPT TY4131 . . . Upright 8.0K, 3/4 in. NPT TY4231.. Pendent 8.0K, 3/4 in. NPT TY4831 . . . Upright 8.0K, 1/2 in. NPT TY4931.. Pendent 8.0K, 1/2 in. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C TFPI7I r 2-3/16" 55,6 mm) 1-1/2" (38,1 mm) STYLE 10 or 20 H- 2-7/8" (73,0 mm) DIA. -H RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing 7 1 / JI1 7/16"___ ____ (11,1 mm) NOMINAL 2-1/4 '\l ill MAKE-IN (57,2 mm) I I 2-3/16" _________ (55,6 mm) I 1-9/16 Lq_~ 6 1/2" NPT** (39,7 mm) WRENCH STYLE 10 or 20 2-7/8 (73,0 mm) DIJ FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT ESCUTCHEON PLATE SEATING SURFACE * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* Lq_~ 7/16 (11,1 mm) NOMINAL MAKE-IN /1.. 2-3/16" (55,6mm) 1/2" NPT** f WRENCH FLATS UPRIGHT PENDENT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient K=2.8 GPM/psi" (40,3 LPM/bar") K=4.2 GPM/psi/2 (60,5 LPM/bar½) K=5.6 GPM/psi/2 (80,6 LPM/bar½) K=8.0 GPM/psi/2 (115,2 LPM/bar½) Temperature Rating Refer to Table A and B Finishes Sprinkler: Refer to Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw.................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8) ....................Bronze Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel* Bulb...............................Glass Compression Screw .....L316 Stainless Steel* Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON Type L316 stainless steel (UNS 31603) per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10,20,30, or 40 Recessed Escutcheon, as applica- ble, for recessed pendent installations. * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 1/2 NPT* UPRIGHT 7/16' 11,1 mm) OMINAL ,1AKE-IN 2-3/16" (55,6 mm) UPRIGHT PENDENT 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) STYLE 1( RECESSELI ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI7I Page 3 of 10 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16 i 11,1 mm) OMINAL 2-ilsfl MAKE-IN (55,6 mm) 2-3/16 1-1/2" _j (38,1 mm) (55,6 mm) WRENCH STYLE 10 or 20 FLATS RECESSED PENDENT ESCUTCHEON CROSS SECTION 2-7/8" (73,0 mm) DIA. RECESSED PENDENT ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N•m). Higher levels of torque can distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to com- pensate for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FR:B Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1 t Figure 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1 to 4, apply the W-Type 7 Recessed Sprin- kler Wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION WRENCH 3/4 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1/2 (12,7 mm) NOMINAL _______ MAKE-IN 2-1 1 A (58,7 mm) (57,2 mm) 1 9/16" STYLE 40 RECESSED UPRIGHT PENDENT ESCUTCHEON 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 4 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 77(12,7mm) ] T(5 5/16NOMINAL _____7 mm) MAKE-IN I 2-1/4 1-9/16 (39,7 mm) Ll~ — $ (572 mm ,, /i 3/4" NPT** t WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON ALL FINISHES EXCEPT POLY-STAINLESS POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT 1 - Frame 5 - Compression 1 2 - Button Screw 3 - Sealing 6 - Deflector * r 3 Assembly 4 - Bulb * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be 6 * provided on special request. PENDENT CROSS SECTION J_1\ 7/16" (11,1 mm) NOMINAL I MAKE-IN v 2-3/16" (55,6 mm) it 1/2" NPT** WRENCH FLATS UPRIGHT CEILING PLATE SEATING SURFACE V. nm) FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFPI7I Page 5 of 10 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) - / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) MOUNTING t SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. 5/8±1/4" (73,0 mm) I 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF - (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) \'4"I MOUNTING / SURFACE/ SERIES 1-1/4" (31,8 mm)_ r CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12 7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I / FACE OF I MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) V77 J MOUNTING SURFACE /' CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) (12 7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF (57,2 mm) ?1MOUNTING SPRINKLER PLATE I FITTING 1/8" (3,2 mm) _ tMOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE TFPI7I Page 6 of 10 2-7/8 DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4 DIA. I 1/4" (6,4 mm) (57,2 mm) MOUNTING PLATE 1/8" CLOSURE SERIES 1-1/4(31,8mm) 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8 DIA. 5/8±1/4 (73,0 mm) '1 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4 (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING li— - ____ ____ (3,2 mm) __ -j MOUNTING I SURFACE . CLOSURE SERIES 1-5/16' (33,3 mm)I TYFRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. I-I (73,0 mm) I 1/2±1/8" 1/2(12,7 mm) oil 27±3,2mm) I 2-1/4" DIA. 1/4(6,4mm) I FACE OF [572 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE if SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) H 1/2" (12,7 mm) :12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF (572 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 7 of 10 Sprinkler Finish5 K- Type Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyester 2.8 1/2 in. NPT Pendent (TY1231) and Upright (TYII3I) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue Recessed Pendent (TY1231)a Figure 6 135°F (57°C) Orange 1,2,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Recessed Pendent (TY1231)b Figure 7 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green 4.2 1/2 in. NPT Pendent (TY2231) and Upright (TY2131) 135°F (57°C) Orange 1, 2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent (TY2231)a Figure 8 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Recessed Pendent (TY2231)b Figure 9 135°F (57°C) Orange 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Fecessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Fecessed Escutcheon, as applicable. C. Frame and Deflector only. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 8 of 10 Sprinkler Finish8 K- Factor Type Temperature Bulb Liquid Color Natural I Brass Chrome Plated Polyesterc PolyStainlessc Lead Coated Pendent (TY3231) 135°F (57°C) Orange 155°F (68°C) Red 175-F (79-C) Yellow and 1,2,3,4,5,6, 7 1,2 1,2,3,5 Upright (TY3131) Blue 200°F (93°C) Green 286°F (141°C) 135°F (57°C) Orange 155°F (68°C) Red 5.6 1/din NPT Recessed Pendent (TY3231)a Figure 10 1, 2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F(68°C) Red Recessed Pendent (TY3231)b 1,2,3,4, N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 11 286°F (141°C) Blue Pendent (TY4231) 135°F (57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow and 1,2,3,4,5,6,7 1,2 1,2,5 Upright (TY4131) Blue 200°F (93°C) Green 286°F (141°C) 135°F (57°C) Orange 155°F (68°C) Red 8.0 3 /4 NPT Recessed Pendent (TY4231)a Figure 12 1, 2, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4231)b 1,2,3,5 N/A N/A 175°F (79°C) Yellow 200°F(93°C) Green Figure 13 286°F (141°C) Blue 8.0 Pendent (TY4931) 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 1/2 in. and 1, 2, 4, 5, 6 N/A 1, 2, 5 NPT Upright (TY4831) Blue 200°F (93°C) Green 286°F (141°C) NOTES Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Not Available (N/A) Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 6. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 9 of 10 Sprinkler Finish K- Factor Type Natural Brass I Chrome Plated Polyester Lead Coated Pendent (TY1231) and 2.8 Upright (TYII3I) 1/2 in. 175 psi (12,1 bar) N/A2 Recessed NPT Pendent (TY1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A NPT Recessed Pendent (TY2231) Pendent (TY3231) and 5.6 Upright (TY3131) 250 psi (17,2 bar) 1/2 in. or 175 psi (12,1 bar)' Recessed NPT Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and Upright (TY4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Not applicable (N/A). Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products o combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Spinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice.lnspections of corrosion-resis- tant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long-term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present. L FINISH 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 - POLYESTER PURE WHITE - POLYESTER (RAL9010)2 SIGNAL WHITE - POLYESTER (RAL9003) JET BLACK POLYESTER (RAL9005)3 7 LEAD COATED 9 I CHROME PLATED TFPI7I Page 10 of 10 PIN 57— XXX— X— XXX SIN SPRINKLER 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 341 4.2K PENDENT (1/2 in. NPT) TY2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (1/2 in. NPT) TY3231 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 391 8.0K PENDENT (3/4 in. NPT) TY4231 360 8.0K UPRIGHT (1/2 in. NPT) TY4831 361 8.0K PENDENT (1/2 in. NPT) TY4931 TEMPERATURE RATINGS I 135 155 I 155-F (68-C) 175 I 175-F (79-C) 200 I 200°F (93°C) 286 I 286°F(141°C) NOTES Available only on TY3131, TY3231, TY4131, and TY4231 Eastern Hemisphere sales only. Available in only 2.8K, 4.21K, and 8.01K, 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLED SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, PIN (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications end other information shows worn current coot document revision date and are subjnct to change without notion. Johnson '1 NATIONAL FIRE PROTECTION ASSOCIATION end NFPA are ,ogivts,od trvdorcnrkv of National Fire P,otootion Asconiotion; Controls TEFLON its registered IradetnurtI of DuPont tqC00 T~rK2_o7_D -D33 Worldwide www.co-fire.com Contacts RAPID RESPONSE Series LFII Residential Sprinklers 49 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Domed-Plate Con- cealed Pendent 4.9 K-factor Sprinklers (TY2234) are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly conceals the sprinkler operating com- ponents above the ceiling. The domed profile of the cover plate provides aes- thetically appealing sprinkler design with lower flow rates than can be achieved by lower profile cover plates. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprinklers and pressure testing of the fire protec- tion system prior to the installation of the ceiling or application of a finish coating. Also, the separable "push-on and thread-off" two-piece design of the Sprinkler provides for 1/2 in. (12,7 mm of vertical adjustment. The Series LFll Residential Sprinklers (TY2234) are intended for use in the fol- lowing scenarios: wet and dry pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Sprin- klers have been designed with heat sensitivity and water distribu- tion characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) are shipped with a Dispos- able Protective Cap. The Protective Cap is temporarily removed for instal- lation, and it must be replaced to protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Protective Cap. When ceiling installa- tion is complete, the Protective Cap must be removed and the Cover Plate Assembly installed. The Protective Cap must be removed to ensure proper performance of the sprinklers. Dry Pipe System Application The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) Listing offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Domed- Plate Concealed Pendent Sprin- klers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is customary for density/area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Domed-Plate Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to AUGUST 2018 not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the NATIONAL FIRE PRO- TECTION ASSOCIATION, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NYC Approved under MEA 44-03-E TFP45O TFP45O Page 2 of 6 SEALING / FRAME ASSEMBLY (1/2 NPT) WRENCH / BUTTON FLATS SUPPORT I I I CUP WITH SPRINKLER I I ROLL FORMED STRAP(SEE I 0 THREADS INSTALLATION I SECTION) BULB DEFLECTOR COMPRESSION SPRINKLER/SUPPORT CUP SCREW ASSEMBLY THREAD INTO RETAINER SUPPORT CUP ' 11 0 101 WITH THREAD UNTIL MOUNTING TABS SURFACE IS II FLUSH WITH H EJECTION CEILING SPRING SOLDER COVER TABS (3) PLATE COVER PLATE/RETAINER ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLERS (TY2234) (Shown with Sprinkler Strap) The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers are only listed with the Series LFII Residential Domed-Plate Concealed Pendent Cover Plates having a factory applied finish. For details on these approvals, refer to the Design Criteria section. All listed cover plates and correspond- ing part numbers having factory applied finishes can be found in the Ordering Procedure section of this data sheet. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 4.9 GPM/psi½ (70,6 LPM/bar½) Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 in. (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Frame .............................Brass Button ............................Bronze Sealing Assembly. Beryllium Nickel w/ TEFLON Bulb (3 mm) ..........................Glass Compression Screw ..................Brass Deflector .........................Copper Button Ejection Spring ........Stainless Steel Support Cup ........................Steel Cover Plate .........................Brass Retainer............................Brass Cover Plate Ejection Spring . . . . Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the Sprinkler Assem- bly. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to acti- vate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Domed-Plate Con- cealed Pendent 4.9 K-factor Sprin- klers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturers recommendations that may be accept- able to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rate are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. The number of design sprinklers speci- fied in NFPA 13D and 13R for wet pipe systems is to be applied when design- ing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover- age area. A minimum discharge of 0.1 gpm/ft2. over the design area comprised of the four most hydraulically demand- ing sprinklers for the actual coverage areas being protected by the four sprinklers. TFP45O Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure b,c Maximum Ccferape Maximum Spacing Ordinary Temp. Rating Ft 155°F (68°C) __________ ___________ Minimum Ft x Ft (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type Ft GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 1/4 in. to 3/4 in. 14x14 14 13 7.0 (4,3 X 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 13 7.0(0,48) (4,9 x 4,9) (4,9) (49,2) 13R Installed in (2,4) 18 x 18 18 17 12.0 (5,5 x 5,5) (5,5) (64,3) (0,83) Beam 1/4 in. to 3/4 in. below bottom of 20x20 20 20 16.7 (6,1 x6,1) (6,1) (75,7) (1,15) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next high- est coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpmlft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEMS SERIES LFII RESIDENTIAL DOMED-PLATE CONCEALED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressureb,c Maximum Coverage Maximum Spacing Ordinary Temp Rating Minimum Area' Ft 155°F (71°C) __________ __________ Ft x Ft (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type Ft GPM PSI (m) (L/min) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings /4 in. to 3/4 in. 14x14 14 14 8.2 (4,3 X 4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or 8 16x16 16 15 9.4 (4,9 x 4,9) (4,9) (56,8) (0,65) Installed in Concealed 13R (2,4) 18x 18 18 20 16.7 (5,5 x 5,5) (5,5) (75,7) (1,15) Beam 1/4 in. to 3/4 in. below bottom of 20 x 20 20 22 20.2 (6,1 x6,1) (6,1) (83,3) 1 (1,39) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL DOMED-PLATE CONCEALED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA 1• TFP45O Page 4 of 6 2-1/2 DIA. SPRINKLER- (63,5 mm) 1/2 (12,7 mm) FACE OF SUPPORT CUP ASSEMBLY 1/2 \ / THREADED SPRINKLER ADJUSTMENT FITTING NPT...J 1 -31 PLATE 3/32' GAP 1-3/16±1/4" COVER mm) - (30,2 mm (2,4 ±6,4mm) RETAINER \\ •/// t MOUNTING SURFACE COVER- SPRINKLER- 15/16" \) 3/4" (19,1 mm) SPRINKLER 1/4" (6,4 mm) OPERATED RETAINER SUPPORT CUP (23,8 mm) ASSEMBLY ASSEMBLY 3-5/16" DIA. PROTECTIVE (84,1 mm) TIP CAP FIGURE 2 DOMED CONCEALED COVER FOR USE WITH RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLERS (TY2234) (Shown with Protective Cap) The number of design sprinklers speci- fied in NFPA 13D and 13R for wet pipe systems is to be applied when design- ing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Pendent Sprinklers (TY2234) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operat- ing sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Sprinkler Spacing The minimum spacing between sprinklers is 8 ft (2,4 m). The maxi- mum spacing between sprinklers cannot exceed the length of the cover- age area (Table A or B) being hydrauli- cally calculated (e.g., maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area). Installation The TYCO RAPID RESPONSE Series LFII Residential Domed-Plate Con- cealed Pendent 4.9 K-factor Sprinklers (TY2234) must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler in the pendent position and with the center- line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Refer to NFPA 13 for guidance regard- ing removal of protective straps and caps Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 7 Wrench shown in Figure 3, install and tighten the Sprinkler/Support Cup Assembly into the fitting. The W-Type 7 Wrench will accept a 1/2 in. ratchet drive. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Pro- tective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. As long as the Sprinkler Strap (Figure 1) or the Protective Cap (Figure 2) remains in place, the system is considered to be "Out Of Service." Step 5. After the ceiling has been com- pleted with the 2-1/2 in. (63 mm) diam- eter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Pro- tective Cap and the Sprinkler Strap. TFP45O Page 5 of 6 NOTE: Refer to Technical Data Sheet TFP700 regarding instructions for the removal of the Sprinkler Strap. Step 6. Push the Cover Plate/Retainer Assembly into the Support Cup, and as necessary, make the final adjust- ment of the Cover Plate with respect to the ceiling by turning the Cover Plate! Retainer Assembly clockwise until its flange just comes in contact with the ceiling. If it becomes necessary to remove the Cover Plate, it can be removed by unscrewing in a counter-clockwise direction. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer Assembly cannot be engaged suffi- ciently to contact the ceiling, the Sprin- kler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Domed-Plate Con- cealed Pendent 4.9 K-factor Sprinklers (TY2234) must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of a Cover Plate may delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. When properly installed, there is a nominal 3/32 in. (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper oper- ation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does not seal off any of the air gap. Failure to do so may impair sprin- kler operation. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Retainer. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or overheated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation section for additional information. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (e.g., NFPA 25), in addi- tion to the standards of any authorities having jurisdiction. Contact the install- ing contractor or product manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFII (TY2234), K = 4.9, Residential Domed-Plate Concealed Pendent Sprinkler without Cover Plate Assembly, P/N 51-873-1-155 Cover Plate Assembly Specify: Series LFII (TY2234), K = 4.9, Residential Domed-Plate Concealed Pendent Sprinkler Cover Plate Assem- bly with (specify) finish, P/N (specify): Pure White* (RAL9010) .....P/N 56-873-3-135 Signal White (RAL9003).....P/N 56-873-4-135 Chrome..................P/N 56-873-9-135 Custom .................P/N 56-873-X-135 * Eastern Hemisphere sales only. Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP45O Page 6 of 6 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of dccument revision date and are subject to change without notice. Johnson '1 NATIONAL :IRE PROTECTION ASSOCIATION nd NFPA ore registered trademarks of National Firs Protection Aceociotion; Controls TEFLON icc registered lrcdsrnarh clDuPoel Recordall® Disc Meters Badger Meter Lead-Free Bronze Alloy, Sizes 5/8'. 5/8" x 3/4' 3/4" & 1" NSF/ANSI Standards 61 and 372 Certified 1#1 Model LP-5/8 5/8" x 3/4" Model 25-5/8 5/8" x 3/4" Model 35-3/4" Model 55-1" Model 70-1" DESCRIPTION The Recordall Disc Series meters meet or exceed the most recent revision of AWWA Standard C700 and are available in a lead-free bronze alloy. The meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI Standards 61 and 372 (Trade Designations: MLP-LL, M25-LL, M35-LL, M55-LL, M70-LL) and carry the NSF-61 mark on the housing. All components of the lead-free bronze alloy meter (housing, measuring element, seals, and so on) comprise the certified system. Applications: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Operation: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register or encoder face. Operating Performance: The Recordall Disc Series meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 ± 1.5%), and maximum continuous operation flow rates as specifically stated in AWWA Standard C700. Construction: Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber, and permanently sealed register or encoder. The meter is available in a lead-free bronze alloy with externally-threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. Magnetic Drive: Direct magnetic drive, through the use of high-strength magnets, provides positive, reliable and dependable register coupling for straight-reading or AMR/AMI meter reading options. Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX® tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. Maintenance: Badger Meter Recordall Disc Series meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like-sized meters and meter models also minimizes spare parts inventory investment. The built-in strainer has an effective straining area of twice the inlet size. Connections: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. Meter Spud and Connection Sizes L " B " Coupling • Tailpiece Model Size x Laying Nut and Pipe Thread Designation Length Bore Dia. Spud Thread (N PT) 5/8" x 7-1/2" 5/8" 3/4(5/8") 1/2" LP 5/8"x3/4" x 7-1/2" 5/8'3/4" 1(3/4) 3/4" 5/8" x 7-1/2" 5/8" 3/4 (5/8") 1/2" 25 5/8"x3/4" x 7-1/2" 5/8'3/4" 1" (3/4") 3/4" 3/4" x 7-1/2" 3/4" 1" (3/4") 3/4" 35 3/4" x 9" 3/4" 1(3/4") 3/4" 3/4" xl" x 9" 3/4" 1-1/4"(1") 1" 55 1" x 10-3/4" 1" 1-1/4(1") 1" 70 1" x 10-3/4" 1" 1-1/4(1") 1" RDM-DS-00464-EN-01 AWWA (April 2014) 1 .i.1Iii4tI [ItIi FIiIit Recordall® Disc Series Meters SPECIFICATIONS Model LP Model 25 Model 35 Model 55 Model 70 (5/8" & 5/8" x 3/4") (5/8" & 5/8" x 3/4") (3/4") (111) (111) Typical Operating Range 0.5 ... 20gpm 0.5 ... 25gpm 0.75 ... 35gpm 1 ... 55gpm 1.25 ... 70gpm (0.11.. .4.5 m3/hr) (0.1l...5.7 m3/hr) (100%± 1.5%) (0.17.. .7.9 m3/hr) (0.23... 12.5 m3/hr) (0.28... 16 m3/hr) 0.25 gpm 0.25 gpm 0.375 gpm 0.5 gpm 0.75 gpm Low Flow (0.057 m3/hr) (0.057 m3/hr) (0.085 m3/hr) (0.11 m3/hr) (0.17 m3/hr) Mm. 95% Mm. 98.5% Mm. 97% Mm. 95% Mm. 95% Maximum Continuous logpm 15 gpm 25 gpm 40 gpm 50 gpm (2.3 m3/hr) (3.4 m3/hr) Operation (5.7 m3/hr) (9.1 m3/hr) (11.3 m3/hr) 5/8" size: 5/8" size: Pressure Loss 2 psi @10 gpm 3.5 psi @ 15 gpm at Maximum (0.14 bar @2.3 m3/hr) (0.24 bar @3.4 m3/hr) 5 psi @25 gpm 3.4 psi @40 gpm 6.5 psi @50 gpm Continuous 5/8" x 3/4" size: 5/8" x 3/4" size: (0.37 bar @5.7 m3/hr) (0.23 bar @9.1 m3/hr) (0.45 bar @ 11.3 m3/hr) Operation 1.5 psi @ 10 gpm 2.8 psi @ 15 gpm (0.10 bar @2.3 m3/hr) (0.19 bar @3.4 m3/hr) Maximum Operating 800 F (26'C) Temperature Maximum Operating 150 psi (10 bar) Pressure Measuring Element Nutating disc, positive displacement Available in NL bronze and engineered polymer to fit spud thread bore diameter sizes: Meter 5/8" size: I Connections 5/8" or I 5/8"(DN15mm) I 3/4"(DN20mm) 1"(DN25mm) 1"(DN25mm) 3/4" (DN 15 mm) 5/8" x 3/4" size: I 3/4" (DN 15 mm) I MATERIALS Model LP (5/8" & 5/8" x 3/4") Model 25 (5/8" & 5/8" x 3/4") Model 35 (3/4") Model 55 Model 70 Meter Housing . Lead-free bronze alloy Housing Bottom Plates Lead-free bronze alloy, cast iron, engineered polymer Cast iron lead-free bronze alloy Measuring Chamber Engineered polymer Disc Engineered polymer Trim Stainless steel Strainer Engineered polymer Disc Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Magnet Ceramic Ceramic Ceramic Polymer bonded Ceramic Magnet Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Register Lid and Shroud Engineered polymer, bronze Page 2 Apri12014 25 - Ro,daIC - 2 IS Aa 7 Gallons • 3.. 4.,..' 5 '''I I 0 1 .5 A RecordsI 2 -.7 Cubic Feet .3-...: jOOOrOofl 4.,. .5 Iii' II, II, 0 1 5 RecordaI 01 .:0,07 m3 0,03-.: 0,05 'IIII ill Product Data Sheet DIMENSIONS Meter Size Model A Laying Length B Height Reg. C Centerline Base Width Approx. Shipping Weight 5/8"and 5/8" x 3/4" (15 mm) LP 7-1/2" (190mm) 3.70(94 mm) 1.26(32 mm) 3.75(95 mm) 3 lb (1.4 kg) 5/8(15 mm) 25 7-1/2" (190 mm) 4-15/16" (125 mm) 1-11/16" (42 mm) 4-1/4" (108 mm) 4-1/2 lb (2 kg) 5/8" x 3/4" (15 mm) 7-1/2" (190 mm) 4-15/16" (125 mm) 1-11/16" (42 mm) 4-1/4" (108 mm) 4-1/2 lb (2 kg) 3/4 (20mm) 35 7-1/2" (190 mm) 5-1/4" (133 mm) 1-5/8" (41 mm) 5" (127 mm) 5-1/2 lb (2.5 kg) 3/4(20mm) 9(229mm) 5-1/4" (133 mm) 1-5/8" (41 mm) 5" (127 mm) 5-3/4 lb (2.6 kg) 3/4" x 1°(20mm) 9(229mm) 5-1/4" (133 mm) 1-5/8" (41 mm) 5" (127 mm) 6 lb (2.7 kg) 1" (25 mm) 55 10-3/4" (273 mm) 6" (152 mm) 2-1/32" (52 mm) 6-1/4" (159 mm) 8-3/4 lb (3.9 kg) 1" (25 mm) 70 10-3/4" (273 mm) 6-1/2" (165 mm) 2-5/16" (59 mm) 7-3/4" (197 mm) 11-1/2 lb (5.2 kg) REGISTERS I ENCODERS Standard—Sweep-Hand Registration The standard register is a straight-reading, permanently sealed magnetic drive register. Dirt, moisture, tampering and lens fogging problems are eliminated. The register has a six-odometer wheel totalization display, 360° test circle with center sweep hand, and flow finder to detect leaks. Register gearing is made of self-lubricating engineered polymer, which minimizes friction and provides long life. The multi-position register simplifies meter installation and reading. The register capacity is 10,000,000 gallons (1,000,000 ft', 100,000 m3). A Model 25 register is used in the following example: Model Gallon Cubic Feet Cubic Meter LP 10 1 0.1 25(5/8") 10 1 0.1/0.01 25(5/8" x3/4") 10 1 0.1/0.01 35 10 1 0.1 55 10 1 0.1 70 10 1 0.1 Optional—Encoders for AMR/AMI Reading Solutions AMRJAMI solutions are available for all Recordall Disc Series meters. All reading options can be removed from the meter without disrupting water service. Badger Meter encoders provide years of reliable, accurate readings for a variety of applications and are also available pre-wired to Badger Meter approved AMRJAMI solutions. See details at www.badgermeter.com. April 2074 Page 3 Model 25 5/8" x 3/4" III1SUII1 I WE zM11MMM I •MONNIMME I -------..---------.I ZONE I • NEENIMME I ---- EEmm __________..I Elmom Model 25 5/8' 1 10 100 25 20 '5 10 Recordall® Disc Series Meters PRESSURE LOSS CHARTS Rate of Flow in Gallons per Minute Model LP 5/8" Model LP 5/8' x 3/4' 10 ]MEN IMIZIMME MEMO M Nagai • _______._._________. _______ ______•.. ________. --------..---------. low ------------------. MEN mmmm= Im Model 35 3/4" 1 I - 0 100 25 20 IS 10 Model 55 1" 10 100 1000 25 20 15 a 10 Model 701" 10 100 1000 Page 4 Apri12014 Model LP 5/8" x 3/4' 0 Model 25 5/8" 1.0 10 100 Model 25 5/8' x 3/4" Model 35 3/4" 1.0 1 0 Model 55 1" 1.0 10 Im 100 .1 Product Data Sheet ACCURACY CHARTS Model LP 5/8' .1 .0 10 100 — — — — - - - — — - — — _ — — - --- — — _ — -- — — — -- - — — - — — - — — - — — - — — - — -- - — - — — - Model 701" I 1.0 10 100 EW E Apri12014 Page 5