Loading...
HomeMy WebLinkAbout3176 LIONSHEAD AVE; ; FPC2019-0235; PermitPERMIT REPORT (ity of Carlsbad Fire Alarm Print Date: 12/02/2020 Job Address: 3176 LIONSHEAD AVE. CARLSBAD, CA 92010-4708 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2218801710 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0235 Status: Closed - Fináled Applied: 10/09/2019 Issued: 10/21/2019 Finaled Close Out: 02/28/2020 Inspector: Final Inspection: Project Title: Description: JFCM LIONSGATE LLC -INSTALL SPRINKLER MONITORING/ ELEVATOR RECALL (16 DEVICES) Applicant: FPContractor: BAY ALARM COMPANY BAY ALARM COMPANY DAN ANDERSON 8205 RONSON RD, # STE F 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 SAN DIEGO, CA 92111-2014 (858) 586-3803 (618) 718-0186 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 FPC Zo 19 -v 02-3S7 I. PROTECTED PREMISE JFCM LIONSGATE LLC 3176 LIONSI-IEAD AVE CARLSBAD, CA 92010 H. MONITORING COMPANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-470-1000 California Alarm Operating License Number: ACO28 III. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 921111 (800) 470-1000 Contractor License # 880138 I I ES-50X Intelligent Addressable FACP with Communicator General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire-Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre-installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire-Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator Optional CELL-MOD or CELL-CAB-FL GSM Central Station Communicator over AlarmNet® Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base Multi-criteria detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterflow selection per module point Alarm verification selection per detector point DF-60953:C (a FIreLuTeALarms by Honeywell Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walktest with walktest log & printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports LiteSpeedTM and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 50 addressable device capacity (any combination of addressable detectors and modules) Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NA CS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time I I I DF-60953:C •7/16/2018 -Pagel of 4 Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 50 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using ES-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. ES-Tools is available on www.firelite.com. User interface LED INDICATORS Fire Alarm (red) CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys Reset (lamp test) Product Line Information ES-50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-50XC, refer to OF- 60954.) FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the ES-50X. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6E cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55E for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN-80: Remote, red LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See OF- 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365: Addressable low-profile photoelectric smoke detector. Lite- Speed only. SD365-IV: Addressable low-profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD3651: Addressable low-profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD3651-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. SD365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low-profile 135°F fixed thermal sensor. LiteSpeed only. H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- Speed only. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low-profile intelligent 190°E/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low-profile intelligent 190°F/68°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices SD355: Addressable low-profile photoelectric smoke detector. SD3551: Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355C0: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of-rise option. H355HT: Fast-response, low-profile heat detector that activates at 190° F/88° C. Page 2 of 4— DF-60953:C • 7/16/2018 I AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (133501-13 base included). B200S: Programmable, addressable sounder base B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFIex low-flow non-relay duct-detector housing; includes S0355R. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order 5D355R/SD365R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R/S0365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. BG-12": Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. DF-60953:C • 7/16/2018— Page 3 of 4 I i I I 1 I W-BGI 2LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES-50X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52 130), CP355 (DF-52383), H355 Series (DF-52385), /300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MD F-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), 5D355/5D355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)/SD350(7) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. I SYSTEM SPECIFICATIONS I System Capacity Intelligent Signaling Line Circuits................................................ Addressable device capacity....................................................50 Programmable software zones.................................................50 Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style V (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, 1,4 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kQ - 22 kQ ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A © 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. NFPA Standards The ES-50X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). -AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). -REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). - CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:0500 FONY: COA6261 NOTE: See DF-60954 for ULC-listed model. AlarmNet®, Fire-Lite® Alarms, SWIFT®, and System Sensot® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 93=1=1 All specifications are subject to change without notice. ENGINEERING & MANUFACTURING QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.firelite.com Page 4 of 4— DF-60953:C 7/1612018 I I Section 9: Power Supply Calculations 9.1 Overview This section contains instructions and tables for calculating power supply currents in alarm and standby conditions. This is a four-step I process, consisting of the following: I. Calculating the total amount of AC branch circuit current required to operate the system Calculating the worst-case system current load on the control panel, when primary (AC) power is applied, to assure that the limit of I the its internal power supply will not be exceeded. This considers the fire alarm condition only. Calculating the total current load on the batteries (secondary power source) in the event of an AC power loss. This considers both standby and fire alarm conditions. Calculating the size of the batteries required to support the system if AC power loss occurs, based on the total battery current load, $ plus a regulatory agency mandated derating factor. 9.2 Calculating the AC Branch Circuit The control panel requires connection to a separate, dedicated AC branch circuit, which must be labeled FIRE ALARM. This branch I circuit must connect to the line side of the main power feed of the protected premises. No other non-fire alarm equipment may be pow- ered from the fire alarm branch circuit. The branch circuit wire must run continuously, without any disconnect devices, from the power source to the control panel. Overcurrent protection for this circuit must comply with Article 760 of the National Electrical Codes as well as local codes. Use 14 AWG (2.00 mm2) wire with 600 volt insulation for this branch circuit. I Use Table 9. 1, to determine the total amount of current, in AC amperes (A), that must be supplied to the system. Number of Current Draw Device Type Devices (AC amps) Total Current per Device ES-50X 1 X 1.75 = CHG-75 [ ] X 2.05 = CHG-120F [ ] X 2.00 = X [ I = Sum Column for AC Branch Current Required = Table 9.1 AC Branch Circuit Requirements 9.3 Calculating the System Current Load 9.3.1 Overview The control panel's internal power supply must support all connected devices while primary (AC) power is applied. The continuous sys- tem current load is highest during a fire alarm condition. To calculate the fire alarm load on the internal power supply, use Calculation Column 1 in Table 9.3 on page 127. The secondary power source (batteries) must be able to power the system under both standby and fire alarm conditions upon loss of pri- mary (AC) power. To calculate the fire alarm load on the secondary power source, use Calculation Column 2 in Table 9.3 on page 127. To calculate the standby load on the secondary power source, use Calculation Column 3 in Table 9.3 on page 127. All currents are given in amperes (A). Table 9.2 shows how to convert milliamperes and microamperes to full amperes. To convert... Multiply Example Milliamperes (mA) to mAx 0.001 3 mAx 0.001 = 0.003A amperes (A) Microamperes (pA) to pA x 0.000001 300 pA x 0.000001 = 0.0003 A amperes (A) Table 9.2 Converting to Full Amperes 9.3.2 How to Calculate System Current Load Use Table 9.3 on page 127 to calculate current load as follows: I. Enter the quantity of devices in all three columns. Enter the current draw where required. Refer to the Device Compatibility Document and SWIFT Manual for compatible devices and their current draw. Calculate the current draws for each in all columns. Sum the currents for each column. This is the total load. Verify that the total from Column 1 is less than or equal to the value specified in the note. Copy the totals from Column 2 and Column 3 to Table 9.4 on page 128. Table 9.3 contains columns for calculating current load. For each column, calculate the current and enter the total (in amperes) in the bot- tom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 9.4 on page 128. For maximum output current available per circuit and per panel, refer to Section 1.2, "Specifications", on page 13. 126 ES-5 OX Series Manual - P/N LS 10129-000FL-E:C 7/25/2018 I I 1 I Calculating the System Current Load Power Supply Calculations Device Type Calculation Column I Primary (AC) Power Source Fire Alarm Current (amps) Calculation Column 2 Secondary (Battery) Power Source Fire Alarm Current (amps) Calculation Column 3 Secondary (Battery) Power Source Standby Current (amps) Qty X[current draw]= Total Qty X [current draw]= Total Qty X [current draw]= Total Main Circuit Board 1 X[0.257]= 1 X[0.141] IPOTS-COM Communicator [ X[0.041]= [ X[0.041]= [ X[0.040] CELL-MOD/CAB-FL [ X[0.100]= [ X[0.100]= [ X[0.055]= ANN-80 [] X[0.040]= [ X[0.040]= [ X[0.015] ANN-100 [1 X[0.025]= [ X[0.025]= [] X[0.020]= ANN-(R)LED [] X[0.068]= [ X[0.068]= [ X[0.028]= ANN-RLY [] X[0.075]= I X[0.075]= [ X[0.015]= ANN-I/O [] X[0.200]= I X[0.200]= I X[0.035]= ANN-S/PG [] X[0.045]= [ X[0.045]= [ X[0.045]= 4XTMF [] X[0.011]2= [ X[O.011]= [] X[0.005]= 4-wire Detector Heads [ X[ 1= [ I X[ V= ] X[ ] Power Supervision Relays4 [] X[0.025] [ X[0.025] [ X[O.025] CP350 & CP355 maximum alarm draw 0.200 for all devices = ______________________________ maximum alarm draw 0200 . for all devices = [ X[0.00030]= SD350, SD355, 5D365 I X[0.00030]= 5D355C0 [ X[0.00030]= SD350T, SD355T, SD365T [ X[0.00030]= AD350 & AD355 [ X[0.00030]= H350, H355, H365 [ X[0.00030]= H350R, H355R, H365R [ X[0.00030]= H355H1, H365HT I X[0.00030]= D350P & D350PL I X[0.00030]= D350RP & D350RPL I X[0.00030]= B501BH & B501BHT5 [ X[0.001]= B224RB I X[0.00050]= B224B1 I X[0.00045]= MMF300 1 X[0.00040]= MMF-300-10 [ X[0.00350]= MDF-300 X[0.00075]= MMF-301 [ X[0.000375]= MMF-302 [ X[0.00027]= MMF-302-6 [ X[0.00200]= BG-12LX I X[0.00030]= CMF-300 I X[0.00039]= CMF-300-6 [ X[0.00225]= CRF-300 [ X[0.00027]= CRF-300-6 [ X[0.00145]= 1300 1 X[0.00040]= ISO-6 [ X[0.00045]= W-GATE [ - X[0.040] or [0.024]6 NAC#17 ] X[ ]= [ ] X[ ]= NAC #2 [ ] X[ ]= [ ] X[ 1= FCPS (remote sync) [ ] X[0.02] [ ] X[0.0217] Current Draw from T133 [ ] [ ]= [ ] [ ]= [ ] [ ]= Sum each column for totals AC Powered, Fire Alarm Load 8 = Battery Powered, Fire Alarm Load 9 = Battery Powered, Standby Load 10 = Table 9.3 System Current Load Calculations 1 Main board with display only. 2 If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. 3 Refer to the Device Compatibility Document for standby current. 4 Must use compatible listed Power Supervision Relay. 5 Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. B When powered by an external source, use 0.040A. When powered by the SLC, use 0.024A. 7 If using Gentex brand NACs, the max number of devices for each NAC output is 35. The UL Max" current rating, published in their data sheets, must be used in order to maintain performance under low battery conditions with the maximum wire resistances shown in Table D.2 on page 141. B Total Alarm current load cannot exceed 3.0 amps. B When AC power is initially applied to the panel and the battery is not fully charged, an initial charge current of up to 5.3 amps may be observed at the battery. This high current is only applied for a very short duration (milliseconds) and does not affect system load or battery size calculations. 10 Total Standby current load cannot exceed 2.25 amps. ES-50X Series Manual- P/N L510129-000FL-E:C 7/25/2018 127 I Power Supply Calculations Calculating the Battery Size 9.4 Calculating the Battery Size Use Table 9.4 to calculate the total Standby and Alarm load in ampere hours (AH). This total load determines the battery size (in AH), required to support the system upon loss of primary (AC) power. Complete Table 9.4 as follows: Enter the totals from Table 9.3 on page 127, Calculation Columns 2 and 3 where shown Enter the NFPA Standby and Alarm times (refer to 'NFPA Requirements' below) Calculate the ampere hours for Standby and Alarm, then sum the Standby and Alarm ampere hours Multiply the sum by the derating factor of 1.2 to calculate the proper battery size (in AH) Write the ampere hour requirements on the Protected Premises label located inside the cabinet door Total Standby Load, Battery Powered Required Standby Time (from Table 9.3 Calculation Column 3) E I (24 hours) X[ I = AH Total Fire Alarm Load, Battery Powered Required Alarm Time (from Table 9.3 Calculation Column 2) (for 5 mm., enter 0.084, for 10 mm., enter 0.168) X[ ] = AH Sum of Standby and Alarm Ampere Hours = AH Multiply by the Derating Factor X 1.2 Battery Size, Total Ampere Hours Required = AH Table 9.4 Total Secondary Power Requirements at 24 VDC 9.4.1 NFPA Battery Requirements NFPA 72 Local, Proprietary, Central, Auxiliary and Remote Fire Alarm Systems require 24 hours of standby power followed by 5 min- utes in alarm. 9.4.2 Selecting and Locating Batteries Select sealed lead acid batteries that meet or exceed the total ampere hours calculated in Table 9.4 . The control panel can charge batter- ies in the 7 AH to 18 AH range. The control panel cabinet is capable of housing batteries up to 18 AH. Batteries larger than 18 AH require a UL listed external battery charger and cabinet such as the BB-26, BB-55F or other UL listed external battery cabinet. 128 ES-50X Series Manual - P/N LS 10129-000FL-E:C 7/25/2018 'Nil DMP.COM 0 0 0 0 0 0 @DMPALARMS :- FEATURES Fully supervised universal alarm communication over LTE, Wi-Fi, or network AT&T or Verizon networks Program your own account number to easily work around locked panels External SMA antenna Use Contact ID dialer capture, four input zones, or bell monitoring Wiring for Ademco ECP Bus Communicates with DMP SCS-1R and SCS-VR Receivers Armed/disarmed status LED Private labeling available on the light pipe insert Two output terminals with multiple output options Program Honeywell® VISTA® panel through DualCom using Compass® DUE COM TM S E R I E S DUALCOM SERIES WORKS WITH MOST PANELS If the existing panel supports Contact ID, it's a candidate for upgrading with DuaIComWZ or DuaIComNF. There are no issues with lockout codes. Simply add the DualCom unit to the existing installation and program in your own account number. UPGRADING HONEYWELL VISTA PANELS The DualCom modules can be programmed to easily takeover Honeywell VISTA panels. The communicator can connect to a VISTA series ECP bus, which will allow you to program the Honeywell panel remotely using Compass. AVAILABLE BURGLARY COMMUNICATION The DualComWZ provides control of basic panel security functions and video. It adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats, and more. FIRE COMMUNICATION The DuaIComNF offers network and cellular fire communication on any fire control panel via Contact ID captures or zone inputs. Meets NFPA 72 Standard for Single Communication Technology. FIRE PANEL TAKEOVER DuaIComNF provides two tip and ring to easily takeover existing fire panels with two phone lines. MOBILE SYSTEM CONTROL With DualCom communicators, you can update your customers' older residential and commercial systems to the latest cellular communication links. With cellular in place, users can remotely access their panels via the Virtual Keypad app. This makes it possible to use their mobile devices not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices. ENABLE VIDEO ON THE APP With the DualCom communicators, you can add up to six video cameras. Via the Virtual Keypad app, users can remotely view their premises to cancel or verify an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION DualCom allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over network or over Verizon or AT&T LTE networks. Sending alarm communication for burglary control panels over network or the LIE network provides higher speeds. FIELD PANEL UPDATES The Model 400 USB Flash Module allows you to conveniently field update firmware for the DualCom that would otherwise require the use of a computer and a Model 399 Programming Harness. DUALCOM PROGRAMMING DualCom programming over network or cell via Dealer AdminTMor Remote Link-includes zone information and monitoring center communications. MULTIPLE CONNECTION OPTIONS DualCom communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer or connect the four input zones from outputs on the panel. Or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the monitoring center. FOUR ZONES Each DualCom model provides four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the app. EASY UPGRADE FOR DIALER-ONLY PANELS Older, dial-up panels have new life with the addition of network or cellular communication. Extend the life of existing customers and add modern panel features at the same time. ADD VIRTUAL KEYPAD APP Enable the Virtual Keypad app on your customers' existing panels for a minimal additional cost. Brand DMP's Virtual Keypad app with your organization's logo and contact information to provide a daily reminder of your services. Specifications Dimensions 5.5W 3.75" H xl' D Color DuaIComNF Red DualComWZ White Primary Power Nominal 12 VDC or 24 VDC Current Draw at 12 VDC Standby 64 mA Alarm 109 mA Current Draw at 24 VDC Standby 30 mA Alarm 82 mA Ordering Information DualComNF-LV Universal Fire Alarm Communicator with Hardwired Network Primary and LIE Backup (Verizon) DuaIComNF-LA Universal Fire Alarm Communicator with Hardwired Network Primary and LIE Backup (AI&1) DualComW7-LV Universal Alarm Communicator with Wi-Fi Network Primary and LIE Backup with 7-Wave (Verizon) DualComWZ-LA Universal Alarm Communicator with Wi-Fi Network Primary and LIE Backup with 7-Wave (AI&1) 685 Surface Mount Conduit Backbox Certifications Cellular FCC Part 15: XMR201707B696 IC: 10224A-2017098696 Underwriters Laboratories (UL) Listed DuaIComNF ANSI/UL 864 Fire Protective Signaling Systems (CID Capture) For additional information, go to DMP.com/Compliance. 800-641-4282 I DMP.com 2500 N. Partnership Blvd, Springfield, MO 65803 Designed, engineered & manufactured in Springfield, NO using U.S. & global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection To read the full DMP Limited Warranty, go to DMP.com/Warranty or check the DMP Price List or catalog. 92019 Digital Monitoring Products, Inc. I ir-iooi 119132 4/19/2019 CONTROL UNIT ACCESSORIES, SYSTEM I UL Product iQ UL Product iQTM UOXX.S3 598 - CONTROL UNIT ACCESSORIES, SYSTEM I * S3598 I I Control Unit Accessories, System See General Information for Control Unit Accessories, System DIGITAL MONITORING PRODUCTS INC 2500 N Partnership Blvd Springfield, MO 65803-8877 USA Investigated to UL 864 (9th edition) Alarm Router Model(s) iCOMsI Battery Model(s) 365, 366, 367, 368, 369 Battery Enclosure Model(s) 341, 349, 352S Battery Harness Model(s) 318, 318EXT, 318R, 318T Bus Splitter Model(s) 710, 710F Control Unit Enclosure Model(s) 352P, 352X Digital Cellular Communicator Model(s) 463C, 463G Dual Line Module Model(s) 893A Enclosure Backbox Model(s) 635 End-of-Line Resistor Model(s) 310 Expansion Interface Module Model(s) 462P, 481 Expansion Module Model(s) 716,717 Fire Control Cabinet Model(s) 348F, 350 Initiating Circuit Module Model(s) 869 Interface Module Model(s) 736P Keypad Model(s) 630F, 692F, 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173(+), 7173A, 7570, 7570A, 7573, 7573A, 790, 793 Notification Circuit Module Model(s) 865, 866, 867 Relay Modules Model(s) 860 RF Receiver Model(s) 1100XR (#) RF Repeater Model(s) 1100R Silence/Reset Switch Model(s) 303 Supplementary Signaling Module Model(s) 462N Transient Suppressor Model(s) 333 Trouble Module Model(s) 377 Wiegand Interface Model(s) 733, 734 Wireless Transmitter Model(s) 1103 (@), 1105-EOL (@) Zone Expander Model(s) 711, 7115, 714, 714-16, 714-8, 715, 715-16, 715-8, 725 https://iqulprospector.com/en/profiIe?e152845 1/2 4/19/2019 CONTROL UNIT ACCESSORIES, SYSTEM I UL Product 10 Investigated to UL 864 (10th edition) Digital Cellular Communicator Model(s) CellComF-LTE-V%, CelIComSLCF Universal Fire Alarm Communicator Model(s) DualComNF-L% - For use with Listed DMP control panel models XR500 and XR100 Series. % - Suitable for use as a Primary Communicator, single communication technology. - For use with Listed Model 1100X and 1100XH Receivers, hOUR (Repeater). Last Updated on 2019-04-17 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC" https://iq.ulprospector.com/en/profile?e=152845 2/2 ANN-80 80-Character Serial LCD Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ- ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-SO is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, and Reset Control switches can be independently enabled or disabled at the FACP Keyswitch enables/disables control switches and mechanically locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4" square electrical box Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80K1T for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the panel Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) Up to eight ANN-80s can be connected on the ANN-Bus Controls and Indicators AC Power Alarm Trouble DF-52417:D • B-gO 8 FIreuTeALarms by Honeywell Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum Ambient' temperature: 32°F to 120°F (0°C to 49°C) Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F) 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep For use indoors in a dry location All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. DF-52417:D •3/15/2018 - Page 1 of 2 WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power circuit is acceptable. Power wire distance limitation is set by 1.2 volt maxi- mum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Ordering Options ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:0211 MEA: 442-06-E Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 ILI MCINEERINS & MRNUFCTORINC QUALITY SYSTEMS Page 2 of 2— OF-52417:D • 3/15/2018 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms. Phone: (800)627-3473, FAX: (877)699-4105. www.firelite.com Country of Origin: USA MMF-300(A) (Type H) I DF-52121:E • E-325 MMF.300(A) Series, MDF-300 (a FureLlTeeALarms I Addressable Monitor Modules by Honeywell I General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4° [10.16 cm] square box) that supervises either a Style 0 (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301 (A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the , devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF.300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPEcIFIcATIONs Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum lOG Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. DF-52121:E • 07/30/2015 - Page 1 of 4 Li I . Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems I 1415 0 1 ADDRESS 113 2 2 11 14 LOOP 0..'5' 1O 5 8 76 8 7 TENS ONES Il I oil IUJ oil jII I.j Uj -jII 10 H I The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Page 204— DF-52121:E 07/30/2015 I Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style 0 application. MMF.302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K Ohms. External supply voltage (between Terminals 110 and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF.300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) lDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301 (A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424. FM Approved. CSFM: 7300-0075:0185. MEA:72-01-E. Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:E •07/30/2015 - Page 3 of 4 FireLite® is a registered trademark and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. . . We cannot cover all specific applications or anticipate all requirements. INffflINC & NNIVACTUMING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121:E • 07/30/2015 df-60379:A1 • E-400 CRF-300(A) Relay Module General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by FiresLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of oft-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control pane: and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mountirg. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. (a FlreLrre®Atarms by Honeywell .... off-, CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125' (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5m5) Coded 30 VDC 0.5 A Inductive (LIR=2m5) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:AI • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. I I I LiteSpeedTM is a trademark and Fire•Lite® Alarms is a registered trademark of Honeywell International Inc. I ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANOfACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. I For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com I Page 2 of 2 - df-60379:A1 • 08/04/09 CM F.300(A) Control Module General The CMF-300(A) Addressable Control Module provides FiresLite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF-300(A) to be activated through panel programming, on a select (zone or area of coverage) basis. LiteSpeedTm is a communication protocol developed by FiresLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry powered directly by two-wire SLC loop. The CMF-300(A) module requires power (for horns, strobes, etc.). Integral LED blinks" green each time a communication is received from the control panel and turns on steady red when activated. High noise immunity (EMF/RFI). The CMF-300(A) may be used to switch 24-volt NAC power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600 series panels, 01 —99 on MS-9200UDLS and MS-9050UD. Applications The CMF-300(A) is used to switch 24 VDC audible/visual power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CMF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. Operation Each CMF-300(A) uses one of the module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/ short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The CMF-300(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the CMF-300(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The df-52130:132 • E-350 FlreLrre®Atarms by Honeywell V Til Et PWRI.I .t ITtU TIC EM PWR(*) SLct)T aci,In 4, - Ax k CMF-300(A) external power supply is always relay-isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll (CLIP mode), 375 pA group poll (LiteSpeed mode) with LED flashing. External supply voltage: maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4' (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ULC: S2424 Product Line Information CMF-300: Intelligent addressable control module. df-52130:B2 • 4/20/10 - Page 1 of 2 ' CMF-300A: Canadian intelligent addressable control module. SMB500: Optional surface-mount backbox. I CB500: Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in the same junction box as CMF-300(A). NOTE: For installation instructions, see document 156-1189-009 I and refer to the SLC Wiring Manual, document 51309. The CRF- 300(A) relay module, previously on this data sheet, is now on OF- 60379. I I I LiteSpeedTM is a trademark and FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1 Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. I For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-521 30:B2 • 4/20/10 1 5D365(A) Series Addressable Photoelectric Detectors General The Fire-Lite SD365(A), SD365T(A), and SD365R(A) Series addressable plug-in photoelectric smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contempo- rary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the 5D365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The 5D365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the 5D365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the Fire-Lite panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0° (10.16 cm) octagonal box, or 4.0° (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA1 OOZ. DF-61 01O:A (a Flre.uTeaAtarms by Honeywell 5D365 Installation 5D365(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5° (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. SD365R(A) mounts in a D355PL(A) or DNR(A) IDNRW duct detector housing. Operation Each 5D365(A) Series detector uses one possible addresses on the Fire-lite Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an ES-50X or ES-200X addressable fire alarm control panel. The results of the sensitivity test can be printed off the for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 200 pA @ 24 VDC. Max current: 4.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0° (5.3 cm) high; base determines diameter. - B300-6: 6.1' (15.6 cm) diameter. - B501: 4° (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). DF-61010:A • 4/2/18 - Page 1 03 1 I Operating temperature range: SD365(A): 0°C to 50°C (32°F to 1221F); SD365T(A): 0°C to 38°C (32°F to 100°F). SD365R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the SD365 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S1059 CSFM: 7272-0075-0502 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: 'IV" suffix indicates LiteSpeedO and CLIP device. NOTE: "A" suffix indicates Canadian version. SD365(A): White, Addressable photoelectric detector; B300-6 base included. LiteSpeed only. SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 base included. SD365T(A): White, Same as 5D365 but with thermal element; B300-6 base included. LiteSpeed only. SD365T(A)-IV: Ivory, Same as SD365 but with thermal element; B300-6 base included. SD365R(A): White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. LiteSpeed only. SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- tric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. 8224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. 8224131-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B2005-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz -i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR3004V: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. DF-61010:A • 4/4/18 - Page 2 of 3 I I 1 I FlreLite® Alarms is a registered trademark of Honeywell International Inc. ©2018 by 1-oneywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be usec for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IS09001 _____ All specifications are subject to change without notice. dl I rl 1 ENGINEERING & MANUFACTURING QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.corr Page 3 of 3— DF-61010:A • 4/4/18 7>r-; Fig. 1 MODEL 302 For interior mounting in any atmosphere that is compat- ible with terminal screw type connections. Fig. 5 AP-P Decorative white plastic adapter plate for mounting 302, 302-AW and 302-El detectors only. Four Basic Models MODEL DESCRIPTION REFER TO: 302-135 135°F - Interior Vertical Mounting FM & UL Fig. 1 302-194 194°F - Interior Vertical Mounting FM & UL 302-ET-135 135°F - All Weather Vertical Mounting FM & UL Fig. 2 302-ET-1 94 194°F - All Weather Vertical Mounting FM & UL 302-AW-1 35 135°F - All Weather Vertical Mounting FM & UL Fig. 3 302-AW-1 94 194°F - All Weather Vertical Mounting FM & UL 302-EPM-1 35 135°F - Explosion Proof Mounting UL Fig. 4 302-EPM-1 94 194°F - Explosion Proof Mounting UL AP-P Decorative white plastic adapter plate for mounting 302, 302E1 j: 5 and 302AW to any 3" outlet box or 4" octagon outlet box. Fig. 2 MODEL 302-El Hermetically sealed for moisture proof or dust proof installations. Requires no special back box. Has plastic hexago- nal grip bushing with 1/2" conduit threads for attachment to threaded hub cover, or any outlet box. Must be hand tightened only. For indoor and outdoor use. Protect from direct sunlight and adverse weather conditions. V/ Fig. 4 MODEL 302-EPM / Explosion proof for installation in hazardous locations. Has hexagonal grip bushing with 1/2' conduit threads for attach- ment to threaded hub cover of series JL fixture fitting as manu- factured by Killark Electric Co., or equal. Must be hand tightened only. For Interior use. Fig. 3 MODEL 302-AW Hermetically sealed for moisture proof or dust proof installations. Requires no special back box. For indoor and outdoor use. Protect from direct sunlight and adverse weather conditions. (actual size) ;ilver contact points sion struts expansion sensing .040 anodized :ontrol sleeve g screw hermetic seal Dimensions (Model 302): Total overall length 4 1187. Base Diameter: Z. General Each model is a normally open device designed especially for fire detection and alarm systems. These rate compensation type detectors are available in either 1350 F or 1940 F ratings. All four basic models are self restoring, hermetically sealed, shock and corrosion resistant, and are tamper proof. Refer to NFPA STANDARD 72, STANDARD FOR AUTOMATIC FIRE DETECTORS for application requirements, testing and maintenance. Principal of Operation All models operate on the principles of a rate compensation detec- tor. The detector consists of a high expansion aluminum tube which encases two insulation struts with opposing open constant points (see cut-away view). The high expansion sensing shell and the expan- sion struts have a different coefficient of expansion. A slow rate of temperature rise allows the heat to penetrate the inner expansion struts. Therefore, the tubular shell and the struts expand slowly until the total device has been heated to its rated temperature level of 1350 Eli 94°F At this point, the silver contact points close which initiates the alarm. When subjected to a rapid rate temperature rise there is not as much time for heat to penetrate the inner strut. The rapid lengthening of the shell allows the struts to come together at a lower level which compensates for thermal lag inherent in conventional fixed temperature detectors. When the surrounding air temperatures goes below the rated temperature level, the shell contracts which forces contacts to open, thus automatically resetting the detector. Special Considerations Temp. Rating OF Max Ceiling Temp. OF 135 115 194 155 Detectors are not directionally effected, can be mounted horizontally or vertically. Detectors have a smooth ceiling UL rating of 50' x 50' (2500 sq. ft.) on 8 to 10 ft. ceilings. Detectors, hub covers, or outlet boxes must never be installed in direct sunlight. Refer to NFPA STAN- DARD 72 for spacing and other considerations. For further information refer to www.thermotechheatdetectors.com Electrical Rating Voltage Current 6-125 VAC 5 amps 6-25 VAC 1 amp 125 VDC 0.5 amp Approvals/Listings Signaling Listed Underwriters' Laboratories I Factory Mutual Approved California State Fire Marshall. Listing No. 7270-0021:001 1 MEA Acceptance # 193-03-E I I I AIR AND MR-100, 200 SERIES in Control MULTI-VOLTAGE CONTROL RELAYS .--- . PRODUCT DESCRIPTION 411LLZ1dAL1& The MR Series Multivoltage Control Relays offer SPDT or DPDT 10 Amp resistive contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, I 2OVAC or 230VAC by wiring to appropriate input terminals. , Each relay position contains a red LED which indicates the relay coil is energized. Relays I may be "snapped apart" from a standard 4 module assembly and used independently. These Devices are Ideal for applications where local contacts are required for system status, remote r I contacts for control of electrical loads and general purpose switching.They are suitable for use with HVAC,Temperature Control, Fire Alarm, Security, Energy Management and Lighting Control Systems. I FEATURES + Relays may be energized from a voltage source of 18 to 35VDC orVAC, I 2OVAC or 230VAC Each relay position contains a red LED, which illuminates when the coil is energized.This provides a time saving device when checking an installed System — no metering is required Single, dual or triple relay modules may be "snapped apart" from standard 4-position master DC control inputs are polarized For continuous duty use at 24VAC, 24VDC, I 2OVAC, or 230VAC Available in dust resistant enclosures with LED viewing port(s) IC vrcinnc mroiintrl in c'nrkociirc :. :. :. :. :. /C/R versions with red covers for NYC and other uses IT versions come complete with track mounting hardware which facilitates installation in standard cabinets UL recognized relays rated at 10,000,000 mechanical operations UL listed as Control Unit Accessory WIRING 0 CSFM LISTED MEA ACCEPTED 94 RECOGNIZED COMPONENT (TYPICAL FOR ONE MR-101 MODULE POSITION) SPDTCONTACT RESISTIVE: 7A @ 30VDC, 10A @ I25VAC, 7A 250VAC INDUCTIVE: .25HP I25I250VAC (NC.), .33 HP 1251250VAC (NO.) 000J RELAY ENERGIZED LED 0 ON NOTE: DC COIL INPUT IS POLARIZED 0 = INPUT I CONTROL 0 18/24 115 230 VOLTAGES 24VDC15mA —P. 24VACi48mA —* 120VAC@21mA —* 230VAC @ 19mA —0- Air Products and Controls is a Brand of Apollo America A 25 Corporate Drive HALMA Auburn Hills, Ml 48326 (248) 332-3900 Phone GROUP (888) 332-2241 To// free COMPANY (248) 332-8807 Fax www.ap-c.com MR-201 DPDT CONTACTS RESISTIVE: 7A @ 3EVDC, lEA @ 125VAC, 7A @ 250VAC INDUCTIVE: .25HP 1251250VAC (NC. .33 HP 1251250VAC (NO.) RELAY I ENERGIZED I LED *I (::ON NOTE: DC COIL INPUT IS POLARIZED INPUT CONTROL • 0 18/24 115 230 VOLTAGES 24VDC @ 28mA — JO.WL 24VAC @698/A —A.C.A.C. 120VAC@45mA — 23OVACI@36mA — L11,iL1IUULtU Dy. PRODUCT SPECIFICATIONS ('CMTA('T CM('I ('CI IDC 1 11 *NAPA rqPKA Ir'j-%L,r\ MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE FILE NUMBER: POSITIONS PER POSITION HXWXD HXWXD MATERIAL 53403 73-92-E 7300-1004 3.25" (82mm) MR-1011T 1 SPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-101!C 1 SPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 14 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 UOXX7 _______ :101 Red _______ MR-101/01IR 1 SPDT ABS-94V0 Vol. 22 Plastic 3.25" (82mm) MR-104/T 4 SPDT 8.50" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-104/10 4 SPDT 5.125" (130mm) 18ga UOXX ______ 9.50" (241mm) 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 14 :101 Red MR-104!C!R 4 SPDT 18ga CRS 3.25" (82mm) MR-2011T 1 DPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-201/C 1 DPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 16 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 UOXX7 ________ :101 Red _______ MR-201/C/R 1 DPDT ABS-94V0 Vol. 22 Plastic 3.25" (82mm) MR-2041T 4 DPDT 8.5" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-204/C 4 DPDT 5.125" (130mm) 18ga UOXX 9.50" (241 mm) 2.50" (63mm) CR S UOXX2 UOXX7 Vol. 16 :101 Red MR-204/C/R 4 DPDT l8ga CRS COIL VOLTAGE: MR-100: 24(18-35)VDC, 24(18-35)VAC, 120VAC, 230VAC MR-200: 24(18-35)VDC, 24VAC, 120VAC, 230VAC (Pull in voltage: 75% of nominal max. @ 25°C; Drop out voltage: 25% of nominal mm. @ 25°C) POLARIZED: DC input only ENERGIZED LED INDICATOR: One per module position CURRENT REQUIREMENT: Per module position: MR-100 Series = 48mAmax/ MR-200 Series = 69mAmax CONTACT RATINGS: 7A © 23VDC I 10A(NO:1/6HP, NC:1/8HP) © 120VAC / 7A @ 230VAC CONTACT CONSTRUCTION: Dry Form "C" ENVIRONMENTAL: 32°F to 120°F (0°C to 49°C) @ 85% RH (@ 32°F), Non-condensing, Non-freezing WIRING: Solid or stranded; #14 to #22 AWG terminals /T VERSIONS: 3.5" wide, low profile plastic snap track provided with mounting screws /C VERSIONS: Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom *UOXX=Control Unit Accessories, System. 2=Component; 7=Certified for Canada NOTICE: The information contained in this document is intended only as a summary and is subject to change without notice. The products described have specific instructional/installation documentation, which covers various technical, approval, code, limitation and liability information. Copies of this documentation along with any gen- eral product warning and limitation documents, which also contain important information, are provided with the product and are also available from Air Products and Controls Inc. The information contained in all of these documents should be Considered before specifying or using the products. Any example applications Shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning the products, contact Air Products and Controls Inc. Aft Products and Controls Inc. reserves the right to change any and all documentation without notice. ©Air Products and Controls Inc. 2012 DS-RL-2 0120607 a CUSTOM DOCUMENT ENCLOSURE tIlLI1 SYSTR RED Modified Mier BW-106R for Bay Alarm 12"W x 12"H x 4"D LI Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks RUNJECORU Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom I Additional customization of this enclosure, or assistance in designing a new model, including color and/or graphics, is available by calling or emailing Mier Products,lnc. I , all t;HT7\ 800-473-0213 1 info@mierproducts.com I www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0500 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Models ES-50X and ES-200X Addressable Fire Alarm Control Units. Automatic, manual, waterfiow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The ES-50X is a compact version of the ES-200X. The ES-50X has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The ES-200X has 198 addressable device capability and 4 Notification Appliance Circuits with 3.oamps total 24VDC output in Alarm expandable to 6.0amps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models ES-50X and ES-200X system components are as follows IPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Interface Module ANN-RLY Form-C Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model ES-200X system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60Hz - INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 I Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I Listing No. 7165-0075:0500 I Page 2of2 management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. I NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. I I I I I I I I I 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator I Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1157:0136 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 331-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN: Models CellComSLC, CellComSLCZ, CelIComSLCF, CellCom-LTE-V, CellComZ-LTE-V, CelIComF-LTE-V, iComSLF, iCOMSL, iComSLZ and *DualComNFL Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Rev 05-13-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Model ANN-80 and *ANN80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listees data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. [1 I I I I I I I I I I I I Li I *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION Fa OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 7272-0075:0502 Page 1 of 1 I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 I Email: pete.sennett@Honeywell.com DESIGN: Models 5D365, 5D365R and 5D365T analog addressable, photoelectric smoke detectors for open area and duct installations. Model 5D365T has a complementary heat detector. All I models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. I Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. I RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), I B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL I (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. XLF: 7272-0028:0503 I I I I 02-01-18 gt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator I Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech lnc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302ET and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-El or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL IM FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America lnc.25 Corporate Dr. Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MRioiIC/R *MR.ioiSSEIC *MRioiSSEIC/R MR-104/C, *MR1041C/R *MR104SSE/C *MR104SSE/C/R MR-201/C, MR201/C/*R, *MR201.SSEIC *MR201SSE/C/R MR-204/C, MR204/C/*R, *MR204SSE/C *MR204.55E/C/R PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RIC-1, RIC-2, RIC-3, RIC-4, MRRIC301/*C, *MRRIC301/C/R MRRlC305*/C, * MR-RIC-305/C/R, MR-RlC-401 */C *MRRlC401/C/R MRRIC405*/C and *MRRlC405/C/R relay modules. *Models MR-ITM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division