Loading...
HomeMy WebLinkAbout3182 LIONSHEAD AVE; ; FPC2019-0076; PermitPERMIT REPORT rcity of Carlsbad Print Date: 10/28/2021 Job Address: 3182 LIONSHEAD AyE, CARLSBAD, CA 92010-4701 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2218801000 Track #: Valuation: $1,188,795.60 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0076 Status: Closed - Finaled Applied: 03/21/2019 Issued: 04/01/2019 Finaled Close Out: 01/07/2021 Inspector: Final Inspection: Project Title: Description: **UPDATED PLAN 4-26-19: BERG ELECTRIC -INSTALL NEW SPRINKLER MONITOR CONTROL PANEL Applicant: FPContractor: BERG ELECTRIC INC BERG ELECTRIC CORP LEON MOORE 3182 LIONSHEAD AVE 955 BORRA PL CARLSBAD, CA 92010-4701 ESCONDIDO, CA 92029-2011 (760) 638-2374 (760) 746-1003 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov rc219-oo17 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. -001 SM BERGELECTRIC HEADQUARTERS - TENANT IMPROVEMENT 3182 LIONSHEAD AVE CARLSBAD, CA, 92008 Project WO #: 120320 Sprinkler Monitoring System February 5, 2019 ELECTRICAL SUBCONTRACTOR Bergelectric Corporation 955 Borra Place Escondido, CA 92029 GENERAL CONTRACTOR ARCHITECT ENGINEER For Review and Approval Stamping 650 Opper Street, Escondido, CA 92029 - Tel (760) 746.1003 Fax (760) 741.0918 - License No. C10-85046 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. -001 SM BERGELECTRIC HEADQUARTERS - TENANT IMPROVEMENT 3182 LIONSHEAD AVE CARLSBAD, CA, 92008 Project WO #: 120320 LIST OF REQUIRED SUBMITTALS Sprinkler Monitoring System Section Para. No. Item Description Submittal Type Submitted Herein Submitted Previously Future Submittal Sprinkler Monitoring Control Panel P X Cellular Dialer P X Misc. Hardware P X C = Certifications D = Drawings P = Product Data TIP = Test Procedures TR = Test Reports DNA = Does not apply to this project bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. -001 SM BERGELECTRIC HEADQUARTERS - TENANT IMPROVEMENT 3182 LIONSHEAD AVE CARLSBAD, CA, 92008 Project WO #: 120320 TABLE OF CONTENTS Sprinkler Monitoring System Section Paragraph Item Description TYPE TAB # Sprinkler Monitoring Control Panel P 1 Cellular Dialer P 2 Misc. Hardware P 3 NAME OF SUBCONTRACTOR: Bergelectric Corporation AUTHORIZED BY: Leon Moore TITLE OR POSITION: Project Manager DATE: 2/5/2019 IlBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. -001 SM BERGELECTRIC HEADQUARTERS - TENANT IMPROVEMENT 3182 LIONSHEAD AVE CARLSBAD, CA, 92008 Project WO #: 120320 TAB # I Sprinkler Monitoring System Sprinkler Monitoring Control Panel EDWARDS Cataog Small Building Fire alarm Solutions echno1oges United LIFE SAFETY INCIDENT MANAGEMENT Intelligent Fire Alarm Systems (10---64-) 101000 Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional EthernetO connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The i064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iO1000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZ116-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. 0 Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases R-Series remote annunciators SIGA-REL Releasing Modules Fully integrated CO detection using Signature Series detec- tors with or without audible signaling FDNY 1OZZ non COA 6227 10,110 waaw ARD 7165-1657: DWARD9 S3000 Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for ciagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Alarm ON command manually activates alarm condition Page 1 of 8 DATA SHEET E85001-0135 Not to be u5ed for installation purposes. Issue 1.2 Application EDWARDS iO Series life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with iO Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the iO Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. i0 control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interface provides common control and 32 LEDs. Programming and remote diagnostics EDWARDS i0 Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, i0 Series systems interface to a PC running com- patible 0-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of 10 Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the ccrrect communications protocols. The connection can be used to download to the panel from the 0-CU, or upload and view system reports using the 0-CU. Available system reports include: Correlation groups Device details Device maintenance History Internal status System configuration System status Walk test Dialer CO runtime Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits EDWARDS i0 Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to 0 technology without the expense or disruption of rewiring the en- tire building. i0 control panels also support the ingenious RZ116-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Signals with a difference 0 system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories 0 Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (2) (3) (4) O7 10 0 T'o 0 0 :O4 Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model D1° I D2 I 03 I D4 I 05° I 06 I Di I 08 I D9 28.0 I 3.85 I 9.0 22.0 15.75 10.25 4.4 28.2 2.7 01000 (711) I (9.8) (22.8) I (55.8)( (26.0) I (11.1) (71.6) I (6.8) 21.5 3.85 7.5 15.54.25 t : 40.0) I 10.25 4.5 I 21.7 2.7 064 (54.6) (9.8) (19.0) (39.4)36.2) (26.0) ) (11.4) (55.1) (6.8) Add 1-1/2 in. (3.81 cm) to D1 and 05 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. l4O2Pl 01 Page 2 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.2 4 3 2 5 6 7 8 10 11 12 13 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries !!! 1 Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply fl Up to eight remote annunciators Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A System Layout iOl 000 Any combination of two single- or dual Signature loop modules ------------------------------------------------------------------- t- -a--s- - - Standard Loop: 250 points (one expansion slot) iO-SDC2 Expander, Loop 1 of 2: 250 points (one expansion slot) I1' 5 H /\HIt1 iD-SDC1 Expander Loop: 250 points (one expansion slot) I 110-SDC2 Expander, Loop 2 of 2: 250 points Up to 20,000 feet of wiring per loop Four Class B or two optional Class A NACs _'qW Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) DACT/Dialer (SA-DACT) __rF! RS-232 (SA-232) Relays: Two Form C, one Form A Each iOl 000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. Four Class B or two optional Class A NACs Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZl16-2 module Panel Layout 1064 F- Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Page 3 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.2 TB3 0 NO NC NO Ø:r 0.-3' NC NO Annuncstor Annunciator CH1(+)lN L__j_I_1TlN CH1(-)lN CHI - IN CH2(+)IN I ' [JCH2H)IN IN CH2 -i IN Class B wiring Class A wiring DLR OLR Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit i01000 1064 specifications _________ Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to fourloops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 lJF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Class B wiring SLC A Data Lisa SL Loop card device device Class A wiring ;K~e-vi SLC A; SLC DLoop card nA Line Notification appliance circuits (TB2) 101000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications 101000 1064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24 VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz, 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 1 50 Hz. Impedance 26 0 total, 0.35 ijF max EOLR 15K0,1/2 W Synchronization Supported system-wide Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. (1) Trcuble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm Trouble Sup?rvisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style ') or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit up to 8 annunciators or 4000 feet impedance Class B Class A Channel 1 Channel 2 Channel 1 Channel 2 Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Page 4 of 8 DATA SHEET E85001-0135 Not to be used for installation purpose;. Issue 1.2 Option Cards EDWARDS 10 Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the i064 as a replacement for the standard 64-point loop, or with the i01000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the i01000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications iO-SDC1 iO-SDC2 Device Addresses i01000: one loop, 250 device addresses 1064: 64 addresses i01 000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 660 resistance Max total loop 0.5 pF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 kO Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring The SA-ETH card provides a To network standard 10/100 Base T Ether- Network cable Network cable_j connection net network connection for connecting to an intranet, a local network, or the Internet. The card can be used to download configuration programming from the i0-CU to the panel. EiIj The Ethernet card is installed on the plastic assembly and con- nects to the main circuit board Ethernet card via a ribbon cable. SA-ETH specifications erzone Interface Modu! - - The RZ116-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI16-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZ116-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 120 mA at 24 VDC nomiaj) Alarm Current '11000 rn 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA/ circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.): 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 ko Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), i01000, APS Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.2 WT SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the 0-CU. SA-DACT Phone line 2 wiring 1hmnei To wall rl"l phone jack Phone cables ......4f......4Ip I (susnlled) RJ31 jacks The dialer phone lines connect to connectors on the dialer's main Q - circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector J1. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31138)) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBII CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface SA-232 wiring The SA-232 card provides an RS-232 in- GND (black wire) terlace with iO panels. It can be used for TXD (white wire) connecting a printer to the control panel RXD (red wire) to print system events. The card also can be used for connecting a computer to download a configuration program from the 0-CU to the control panel. fl fl The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard ElA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with iO64 control panels only. iO1000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A F'INR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16L-iO LED Display Expander (i01000 only) The Dl 6L-10 LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D1 6L-10 LED display expanders can be installed in each 101000 panel. (4) LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs (5) Page 6 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.2 Specifications 1064 101000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style 't), Class A (Style Z) optional 4 Class B (Style 'I or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max, 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 172 mA Base panel current alarm (2O4mA) 267 mA Input zones (ë max.) 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the i064 and 101000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 IJF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iO1 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38)<) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kG Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7 of 8 DATA SHEET E85001 -0135 Not to be used for installation purposes. Issue 1.2 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 8 of 8 Ordering Information Part Description i01000 Fire Alarm Systems 1010003 Four loop system with one 250-point loop installed. 110v, gray door. I01000G-2 Four loop system with one 250-point loop installed. 230v, gray door. I01000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. 1010003-2-SF Four loop system with one 250-point loop installed. 230v, gray door, Spanish. I01000G-CA Four loop system, one 250-point loop installed. 11 Dv, gray door, LED strips, Canada. I01000GD Four loop system, one 250-point loop installed. 110v, gray door, with dialer. I01000G-F Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. 01 000G-PG Four loop system with one 250-point loop installed. 11 Dv, gray door, Portuguese. 1010003-SF Four loop system with one 250-point loop installed. 110v, gray door, Spanish. 101 DOOR Four loop system with one 250-point loop installed. llOv, red door. 101 000R-2 Four loop system with one 250-point loop installed. 230v, red door. 101 000RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. SA-11R1M2 101000 Flush mount trim, black. i064 Fire Alarm Systems 10646 One loop system with one 64-point loop installed. 11Ov, gray door. 1064G-2 One loop system with one 64-point loop installed. 230v, gray door. 10643-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 1064G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. 1064GD One loop system, one 64-point loop installed. llOv, gray door, with dialer. 1064GL One loop system, one 64-point loop installed. llOv, gray door, English Canada. 1064GL-F One loop system, one 64-point loop installed. 110v, gray door, French Canada. I064G-PG One boo system with one 64-ooint boo installed. 110v, orav door, Portuuuese. 1064R One loop system with one 64-point loop installed. 110v, red door. 1064R-2 One loon system with one 64-øoint loo installed. 230v, red door. SA-TRIM1 i064 Flush mount trim, black Option Cards iO-SDC1 Expansion module, one 250-device loop. iO-SDC2 Expansion module, two 250-device loops, 500 devices total. For iO1 000 only. —*RZIi6-21 fRemote Zone Interface Module. 16 Class B lDCs, 2 Class B Output. Includes bracket.) SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. i064 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For i0l 000 only. D16L-iO-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For iOi 000 only. D8RY-iO-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iOi 000 only. D8RY-iO-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1 000 only. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8' x 14" x 3.5' - red. SIGA-REL Releasing Module PT-1S System Printer —~(BC i) (Battery Cabinet. 140 x 18 25 x 7 25 Holds LWO 12V24A battenes) BC-1 A Battery Cabinet - Red. 14.0' x 18.25' x 7.25". Holds two 12V24A batteries. BC-i EQ Seismic hardening Kit for i0 series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools iO-CU 10 Series configuration and diagnostics utility. 260097 RS232 cable, 4 conductor, D69 PC interface DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7i65-1657:0244) - Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow and sprinkler supervisory service. Models "EST" iO1000G, iO1000G-2, iOI000GD, i01000R, iO1000R-2, i01000RD, i064G, 064-GD, i064-R,664-RE iO64G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VS1-G, VSI-GD, VS1-R, VS1-RD, VSI-G-2, VSI-R-2; VS2-G, VS2-GD, VS2-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FX1000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module DI6L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XALI27; SLC Loop Driver io-SDC1, V-SLC2-1, FX-SLC1 Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pT1S: System Printer *pT1p: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires iine3O, 2O1) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listec compatible initiating and indicating devices. *These control units meet the requiremen of UL 864, 9th Edition Standard. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This list -ig should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructicns and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 300-165032) Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: ModeIsZI16- RZ116-2R5 Remote Zone Interface Modules and Model RZI-MPL Mounting Bracket. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as remote zone interfaces for use with separately listed compatible fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 11-24-l5gt This listing is based upon technical data submitted the test results and/or other data but does not by the applicant. CSFM Fire Engineering staff make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires Qu_ne~0, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (O0-1657:0i Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SlGA-CC1, SlGA-CC2, SIGA-CTI, SIGA-CTIHT, SIGA-CT2, SlGA-CR, SIGA-CRR, SIGA-UM, SlGA-MMI, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCCI, SIGA-MCC2, SIGA-MCR and SlGA-MCRR remote transponders. Models SlGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SlGA-MPI, SlGA-MP2 and SlGA-MP2L mounting plates. Models SIGA-UI02R, SIGA-U106 and SIGA-U106R motherboards. Model CS-SIGA-CCIP releasing module. Models SIGA-CC1S and SlGA-MCC1S Auto-Sync Output Modules. ModelsAFC-.'and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CTIHT; Signature Series High Temperature Single Input Module. *SIGACRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires , Iii) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. -001 SM BERGELECTRIC HEADQUARTERS - TENANT IMPROVEMENT 3182 LIONSHEAD AVE CARLSBAD, CA, 92008 Project WO #: 120320 Sprinkler Monitoring System Cellular Dialer TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS Il1Ic191N10 The straightforward web This advanced tool has multi-level user authorization and p.roVides ' total account'management of UL Listed Telguard cellular, alarm communicators. 1 -- -' Telguard Cellular Service i: Telguar Cellular Service provs AT&T LTE network coverage fo all Telguard units. Telguard's Comm nication Center is UL comph and provides seamles' connectivity between the alarm panel, the Telguard family of products and the central station. Telguar'd Technical Support provides a single point of contact for both cellular service and Telguard product questions V eatLreste ability to tthlize müliecllular te'chnolcgies to .increasavailability and reduce - false aiatrns. L -. 'U to M. With central statio btification ensure the cellla system is operat ng. Available relay output for tripping the alarm control panel when a trouble condition occurs. 6 COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LTE network for long, sunset-free installation. : Meets UL 864 requirements for sole, primary or backup path communications. - Minimizes false alarms by providing dual paths for self-tests. Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72 the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs trie end user significantly less than a dedicated landline. For each lancUne replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the centra station within sixty minutes of an outage, the TG-71FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. mo FC( 0°C to (non-c AA TE LG UARD TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS C)pton. I) Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low Foss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 control units & accessories for fire alarm systems Commercial Burglary 365 Police Station ccnrsected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 Household fire warning systems 1023 Household burglar alarm systems ULC Listings S545 Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 Canadian household burglary alarm systems For the most current product specifications and U. Listings visit www.Telguard.com. c®us C] :•: LISTED NFPA //Ita Connected JU U U NTERWMIOAL byAT&T Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 www.Telguard.com Copyright c 2017 Telular Corporation All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7LA001 TG7LA002, *TG7LAF01 TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF01 TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0110 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LVO01 *TG7LVA01 *TG7LVF01 and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used lo provide a primary (sole or with a back-up) or back-up transmission path using cellular-for control communicators. Refer to listee's printed data sheet for additional detailed pfocuct description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes. End ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's !nstallation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. -001 SM BERGELECTRIC HEADQUARTERS - TENANT IMPROVEMENT 3182 LIONSHEAD AVE CARLSBAD, CA, 92008 Project WO #: 120320 TAB #3 Sprinkler Monitoring System Misc. Hardware ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords Solid stainless steel piano hinge and other critical system information. Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information _____ 001 Space Age Electronics, Inc. Made IS.A. REGISTERED qY 800486.1723 Toll F MEMBER NVY 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, Just Solutions! ED0549 LT10559 Rev.D 1/2 Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available OMSPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-1 Connector P,nparty IntunmntIm, Onav Co,tlficatlonn and Appruvala 16.1 System Installation Con5aeto, ew- Minimum Rvqulmd Documentation 615-PUN) 16.5 AuThOnly Having Jurisdiclion: Ommdn.Oflh.n.medo0atOW,d1talIma. ID CntIS I OS d.v,. t 1:05 .S In I,--- s_s 010-450.1723 ,O.,.I..., 1110644 Ra, 1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7600553:011 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, lF1, IFX/A and IFX/D encIosures.(odels ACE-11) ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires (ne 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS5 Catalog P Intelligent Input-Output LIFE SAFETY ' INCIDENT MANAGEMENT Input Modules SIGA-CT1, SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 SIGA-MCT2 MEA 0 7357: 0121 S3424 Overview The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SlGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (lDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 "F to 158 "F (0 "C to 70 "C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. S1GA-CT1HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page lof4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SlGA-PRO Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1, SIGA-CT1 HT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. UIO Motherboard 6-32 / Self-tapping I screws (U10 Module screws ) >Captivc 16 Flat washers Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SlGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). Compatible electrical box NORMALLY-OPEN ALARM — LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to s. the loop contrcller when the input contact is closed. The alarm Wall plate, white condition is latched at the module. (1-ga) n, NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- V "•. ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal Q. is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the Ds module. LED viewing ports II • •'. II SIGA-MCT2: mount the UlO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SIGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. NORMALLY-OPEN ACTIVE — NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE — LATCHING (Personality Code 4) — Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. Page 2of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 5 DATA t'(+)> DATA OUT DATA IN DATA OUT C.) From Signature Controller To Next Device or Previous Device A SIGA-CT2 lypinol NO initiating 00640 tjl./ULC 11006 07KW WI ULIrJLC Listed 47KW KOL ubeocerlee n,uoherboord :: J,1U Data Data out TB I Gnsen LED IN.—I) dL40 required for MCIZ. SlGA-MCT2 Typical Wiring Modules will accept #18 AWG (0,75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4000ft(1,219m) #14 AWG (1.50 mm2) #12 AWG _(1.50_mm2) Typical N.C. Initiating Device Typical N.C. Initiating Device INPUT 1 INPUT 2 A AA Sle B (C B) ___ AK TB2 I I TB2 87 UJCLed 47M EOL UL/ULCListed Style (Class 87 65 Ud Red LED DI Green LED II (Alerm/Aclive) j J (Normal) Red LED (Abrm/Acflve) 4 32 ! 4] Green LED 432i (Normal) TB1rEElfr1 TB1W(D51 i 5 DATA IN (+)) I I DATA OUT (+) DATA IN (.) > .J DATA OUT (.) From Signature Controller I To Next Device or Previous Device SlGA-CT1, SIGA-CT1 HT NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2) wire; Minimum #18 AWG (0.75 mm2) Refer to Signature controller installation sheet for wiring specifications Maximum 10 Vdc @ 350 iA The SIGA-ul06R and the SIGA-UI02R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Page 3 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: edwards-flre.com 1016 Corporate Park Drive Mebane, NC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. All rights reserved. Specifications Catalog Number SIGA-CT1 HI I SIGA-CT1 SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates U102R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) to 0 to 9 C) Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog - Ship Wt. Number Description lbs (kg) SlGA-CT1 HT Single Input Module High Temperature Operation UL/ULC Listed 0.4 (0.15) SIGA-CT2 Dual Input Module - ULIULC Listed 0.4(0.15) SIGA-MC2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) SIGA-UIO2R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0 32 0 15 SIGA-UIOSR Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0 62 0 28 SIGA-UIOS Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) SIGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) SIGA-MPI Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CC1, SIGA-CC2, SIGA-CT1, SlGA-CT1HT,(SlGA-CT) SlGA-CR, SIGA-CRR, SIGA-UM, SIGA-MM1, SIGA-WTM, SIGA-IM, SIGA.-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCC1, SIGA-MCC2, SlGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SlGA-MB4, SlGA-MP1, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UlO2R, SIGA-U106 and SIGA-UlO6R motherboards. Model CS-SlGA-CC1P releasing module. Models SlGA-CCIS and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CT1HT; Signature Series High Temperature Single Input Module. *SIGA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt Øri This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1V%* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1657:0223 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models ESD-SJ, ESD-ST, TSD-SJ, TSD-ST, TSD-SJG, TSD-SJCO2, TSD-STCO2, SIGA-SD, SD-2W, ESD-2W, E-PDD, and FX-PDD photoelectric type duct smoke detectors. The duct detector consists of a thermoplastic enclosure, recognized component printed wiring board, a listed duct detector subassembly, and an inlet coupling tube and an exhaust tube along with gaskets. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15.2-19.95 VDC 16-30 VDC: SD-2W, ESD-2W INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type, duct smoke detectors for use with separately listed compatible fire alarm control units in conjunction with Models ESD-CJ, -CT or TSD-CJ, -CT series duct smoke detector controller (CSFM Listing No. 3240-1657:225). Models SlGA-SD, E-PDD, FX-PDD, SD-2W or ESD-2W does not require a listed duct smoke detector controller. Suitable for use in ducts where air velocity is between 100 and 4000 ft/mm. *Models ESD-SJ, ESD-ST, TSD-SJ, TSD-SJG, TSD-SJCO2, SIGA-SD, SD-2W and ESD-2W are suitable for use in ambient temperatures of -4°F to 158°F. Refer to listee's Installation Instruction Manual for details. NOTE: 1. CO2 sensing features were not examined. 2. Formerly 3242-1591:223 *Corrected 3-22-13 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EVAN dj es LIFE SAFETY ' INCIDENT MANAGEMENT EDWARDS Catalog " Intelligent Input/Output High Power Control Relay Module SIGA-CRH Description The SIGA-CRH High Power Control Relay Module is an address- able device designed for interface applications that require a high voltage, high current relay. Two identical sets of relay terminals are provided. Both sets of relay contacts transfer when the module is activated or restored. The state of the output terminals is not supervised. The module requires one address on the signaling line circuit (SLC). The address is assigned electronically. There are no ad- dress switches to set. Standard Features High Power Rating 120/240 VAC or 24 VDC rated contact can be used to control external appliances such as door closers, fans, dampers etc. Provides one relay with two Form C contacts Relay accepts 12 to 18 AWG (1.0 to 4.0 mm2) wiring from two sources Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Removable terminal blocks Easy wiring and module replacement. Electronic addressing Programmable addresses are downloaded from the loop con- troller or PC; there are no switches or dials to set. Intelligent device Distributed intelligence allows lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Page lof 4 DATA SHEET E85001-0644 Not to be used for installation purposes. Issue 1 Application Personality code Use Personality Code 8 to configure the SIGA-CRH module: Personality code 8: Signal - dry contact output. Configures the module as a dry relay contact to control external appli- ances (door closers, fan controllers, dampers) or equipment shutdown. Indication The status LED shows the state of the module through the cover plate: Normal: Green LED flashes Alarm/active: Red LED flashes Compatibility The SIGA-CRH is part of the Signature Series intelligent process- ing and control platform. It is compatible with EST3, EST3X, and iO Series control panels. Warnings & Cautions The SIGA-CRH will not operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Installation Compatible electrical box plate Consult the SIGA-CRH High Power Control Relay Module Installa- tion Sheet for details. Wiring IU i ii pi___ iIi iiJ Il (4) Testing & Maintenance SIGA-CRH automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. Electronic Addressing The loop controller electronically addresses the SIGA-CRH, saving valuable time during system commissioning. Setting complicated switches or dials is not required. The module has its own unique serial number stored in its on-board memory. II I 0 u___..Q_.0 2cs 0 C 0 Signaling line circuit (SLC) from previous device Signaling line circuit (SLC) to next device Power-limited and supervised Normally closed contact (NC) Common contact (C) Normally open contact (NO) Relay terminal set 2. Not supervised, Power-limited unless connected to a nonpowerlimited source. If the source is nonpower-limited, eliminate the power-limited mark and maintain a minimum of 0.25 in. (6.4 mm) space from power-limited wiring. For other mounting methods, see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring. The wire size must be capable of handling fault current from a nonpower-limited source. - or - Use type FPL, FPLR, FPLP, or permitted substitute cables, provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in. (6.4 mm) space or by a nonconductive sleeve or nonconductive barrier from all other conductors. Refer to the NFPA 70 National Electrical Code for more details. Relay terminal set 1. Identical to (7). Page 2of4 DATA SHEET E85001-0644 Not to be used for installation purposes. Issue 1 Specifications SLC operating voltage 15.20 to 19.95 VDC SLC current Standby 75 ijA max. Activated 75 pA max. Ordering Information Catalog Ship Weight Description Number lbs (kg) SIGA-CRH High Power Control Relay Module 0.4(0.15) Contact ratings [1][2] 240 V 50/60 Hz 120 V 50/60 Hz 24 VDC Audio switching Relay type Relay ready delay From power up From previous activation Circuit designation Signaling line circuits Relay circuits Number of SIGA-CRH per SLC Wire size Compatible electrical boxes Agency Listings Operating environment Temperature Relative humidity Storage temperature 7 A (PF 0.75), 1.5 A (PF 0.35) 7 A (PF 0.75), 3.0 A (PF 0.35) 6 A resistive 0 to 20 kHz [3] 2 Form C, programmable 30 s max. (includes initial state set) 5 s max. (one activation) 8 s max. (two activations, 1 s apart) Class A, Style 6 or Class B, Style 4. Refer to the control panel technical publications for SLC wiring details. Class E 60 max. 12 to 18 AWO (1.0 to 4.0 mm2) North American double-gang x 2-1/8 in. (54 mm) deep box North American standard 4 in. square x 2-1/8 in. (54 mm) deep box CAN/ULC-5527, UL 864 32 to 120°F (0 to 49°C) 0 to 93%, noncondensing —4 to 140°F (-20 to 60°C) Provide external fusing and back-EMF mitigation as required by your application. Do not use the SIGA-CRH in a mixed application, where one set of relay terminals has high-power requirements and the other set carries a low-power signal, as this may result in physical contamination of the low-power signal contacts. The minimum load required in order to avoid long-term contact oxidation is 100 mA and 12 V Power must not exceed the contact ratings shown for a given PF (power factor). Page 3 of 4 DATA SHEET E85001-0644 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.flre@fs.utc.com Web: edwards-flre.com 1016 Corporate Park Drive Mebane, NC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. All rights reserved. Page 4 of 4 :ATA SHEET E65001-0644 to oe used ;or InstaJadon ptrposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CC1, SIGA-CC2, SIGA-CT1, SIGA-CT1HT, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MM1, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCCI, SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SlGA-APS-220 power supplies. Models SlGA-MB4, SlGA-MPI, SlGA-MP2 and SlGA-MP2L mounting plates. Models SIGA-UIO2R, SIGA-Ul06 and SlGA-UI06R motherboards. Model CS-SlGA-CC1 P releasing module. Models SIGA-CCIS and SIGA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CT1HT; Signature Series High Temperature Single Input Module. SlGA-High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt T1' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1V1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog Intelligent Initiating LIFE SAFETY INCIDENT MANAGEMENT Intelligent Duct Smoke Detector SIGA-SD '2~ a & MEA 3242-1657: 0223 S853 I Overview The EDWARDS SuperDuct Signature Series smoke detector is the most advanced and most reliable device in its class. Designed for easy installation and superb reliability, SuperDuct represents the perfect balance of practical design and advanced technology. SuperDuct detectors feature a unique design that speeds instal- lation and simplifies maintenance. Removable dust filters, confor- mally coated circuit boards, and optional water-resistant gaskets keep contaminants away from components, ensuring years of trouble-free service. When cleaning is required, the assemblies come apart easily and snap back together in seconds. Standard Features Less than 2" deep for easy installation and applications where space is tight -20°F to 158°F (-29°C to 70°C) operating range with 100 ft/ mm. to 4,000 ft/min air velocity rating assures reliability under harsh environmental conditions Status LEDs remain visible through clear assembly cover Cover monitor switch for added security Standard sampling tube spacing for easy drop-in migration from other detectors A Signature Series photoelectric sensor is incorporated into • Sampling tube can be installed with or without the cover in the design of each SlGA-SD duct smoke detector. This sensor place and can be rotated in 45-degree increments to ensure inherits the power and benefits of this exceptional line of intelligent proper alignment with duct airflow devices. 15.2 to 19.95 Vdc operation Signature Series sensors gather analog information from their smoke sensing elements and convert it into digital signals. The sensor measures and analyses these signals and compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires, which virtually eliminates unwanted alarms. WARNING: Duct detectors have specific limitations. Duct detectors are not a substitute for an open area smoke detector. Duct detectors are not a substitute for early warning detection or a replacement for a building's regular fire detection system. Smoke detectors are not designed to detect toxic gases which can build up to hazardous levels in some fires. These devices will not operate without electri- cal power. As fires frequently cause power interruptions, EDWARDS suggests you discuss further safeguards with your local fire protection specialist. Magnet-activated test switch One Form C auxiliary alarm relay for controlling ancillary equip- ment (e.g., HVAC controls) No special tools required for easy access to field connections Signature Series intelligence Environmental compensation with differential sensing for reli- able, stable, and drift-free sensitivity Wide 0.79% to 2.46% obscuration/ft. smoke sensitivity Identification of dirty or defective detectors Page 1 of 4 DATA SHEET E85001-0584 Not to be used for installation purposes. Issue 1 Dimensions Application SuperDuct detectors are ideally suited to duct smoke detection applications where early indication of combustion is required within the confined space of ventilation ductwork. Its primary purpose is to provide early warning of an impending fire and to prevent smoke from circulating throughout the building. It is typically used to detect smoke in the supply side of the HVAC system but can provide supervision of the return side as well. -------------------------------- Protected premises Remote I Alarm relay test output station = - H Edce't:e.:to:r p Return - HVACT unit = HDuct smokeF..1 E= Supply detector ai Alarm relay output test W SuperDuct detectors continually sample air flow in the HVAC duct and initiate an alarm condition whenever smoke is detected. An alarm is activated when the quantity (percent obscuration) of combustion products in that air sample exceeds the detector's sensitivity setting. Signature Series Intelligence Like all Signature detectors, the SIGA-SD features electronic addressing and issues a dirty sensor warning when it reaches its preset limit. The dirty sensor warning indicates the sensor is op- erating within its specified limits but is in need of servicing. When the detector's ability to compensate for environmental changes has reached its limit, the duct smoke detector signals a trouble condition. The SlGA-SD also uses differential sensing to prevent gradual environmental changes from triggering unwanted alarms. A rapid change in environmental conditions, such as smoke from a fire, causes the detector to signal an alarm state, but dust and debris accumulated over time does not change alarm sensitivity. Each Signature Series SuperDuct detector contains a microproc- essor that performs comprehensive self-diagnostics and stores the results in nonvolatile memory. Stored results include details such as hours of operation, last maintenance date, and number of alarms and troubles. This information can be retrieved and reviewed when desired. Detector Configuration The detector assembly cover provides easy access to the smoke sensor, its wiring connections, sample and exhaust tubes, and the smoke chamber itself. Air enters the detector's sensing chamber through a sampling tube (ordered separately) that extends into the duct and is directed back into the ventilation system through an exhaust tube (in- cluded). The difference in air pressure between the two tubes pulls the sampled air through the sensing chamber. When a sufficient amount of smoke is detected in the sensing chamber, the detector initiates an alarm. The sampling tube may be installed from either the duct side of the assembly or from inside the sensor compartment, as preferred by the installer. (The exhaust tube must be installed from the duct side.) Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be mounted at virtually any angle relative to the air flow. In installations where the duct smoke detector's controls and indica- tors are hidden from view, a remote test station or an LED indicator can be connected to the detector to provide these functions. Remote Test Stations . Labor-saving Remote Test/Reset stations provide alarm testing from the convenience of a remote location. Tests can be performed quickly and safely without having to climb to the roof. Magnetically- operated and key-operated one-gang models are r-- available. Signature SuperDuct detectors are also compatible with SIGA-LED remote alarm LED. Air velocity in the duct as low as 100 ft/mm. maintains adequate air flow into the sensor smoke chamber through air holes in the air sampling tube and discharges through the exhaust tube. Su- perDuct air sampling tubes must be installed with the inlet holes facing the airstream. Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be mounted in virtually any angle relative to the airflow. SuperDuct sensors are engineered to operate optimally under the harsh environmental conditions frequently found in HVAC duc- twork. Nonetheless, before installing the detector, test the duct air velocity, temperature, and humidity to verify that it is within the operating range of the SuperDuct detector. Consult the SuperDuct installation sheet for details. 1.38 in 5.40 in (3.51 crc) (13.72 M) Page 2 of 4 DATA SHEET E85001-0584 Not to be used for installation purposes. Issue 1 "Assembly High-humidity environments Sampling tube socket Exhaust tube Detector socket Use the SD-PH Protective Housing when installing SuperDuct detectors in high-humidity environments. The SD-PH is a weather- ized housing that prevents condensation on the device by insulat- ing the detectors and providing circulated air from the monitored HVAC duct. The SD-PH also adds a layer of protection against physical damage to the unit. Exhaust tube 9 Tin gasket - gasket Thick k coupling Duct tube Protective Housing ( Sampling ordered separately) Detector Plug Motintina Airfi #10 sheet metal screw (2X) Wiring Auxiliary equipment [1] No more than one remote test station or LED indicator can be connected to the detector at the same time. Wiring 17 16 15 is unsupervised. Maximum wire LMII j resistance is 10 ohms per wire. Data In (+) Data In (-) I Housing Detector air tube conduit holes The SD-PH is easy to install and service. The hinged and transpar- ent cover provides ready access to the detector, while keeping its status indicators visible at all times. Note: The SD-PH Protective Housing is weatherized against out- door air, but it is not intended for direct outdoor exposure. $ SIGA-LED [11 Alarm r ___________ o - ® Alarm SD-TRK Test or SD-TRM (1] Data Out (-) r Data Out (+) 0000 Power indicator Alarm indicator Page 3of4 DATA SHEET E850010584 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwarts.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications, detector 8.70 x 5.45 x 1.90 inches Dimensions (221 x138x48mm) Wire size 14 to 22 AWG Detection Photoelectric method (light scattering principle) Air velocity 100 to 4,000 ft/min and rating meets the required minimum air pressure differential Air pressure 0.005 to 1.00 inches of differential water Sensitivity 0.79 to 2.46%/ft obscuration Alarm test 5 seconds response time LED indicators Alarm (red), Power (green) Unsupervised and power- limited Common Quantity: 1 alarm relay Type: Form C Ratings: 2.0 A at 30 Vdc (resistive) Operating 15.2 to 19.95 Vdc voltage Operating Standby: 45 pA Alarm: 45 current pA Inrush: 1 mA Standalone alarm: 18 mA Temperature (UL): -20 to 158 °F(-29 to 70°C). Operating Temperature (ULC): -4 to environment 120 °F (-29 to 49 °C) Relative humidity: 10 to 93%, noncondensing Agency UL, ULC, CSFM, FM, MEA Specifications, test stations Remote Test/Reset Stations provide alarm test, trouble indication, and reset capability from a remote loca- tion. They include a one-gang plate, momentary SPST switch, red alarm LED, and terminal block. Magnetically- operated models (TRM) or key-operated models (TRIg are available. Compatible North American 1-gang box electrical Standard 4-in square box, boxes 1-1/2 inches deep, with 1 -gang cover LED indicators Alarm (red) LED type Clear lens Wire size 14 to 22 AWG Resistance per 10 Ohms, max. wire Current See controller specifications requirements LED circuit Voltage: 3 Vdc, max. ratings Current: 30 mA, max. Switch ratings Voltage: 125 Vdc, max. (SD-TRl Current: 4 A, max. Switch ratings Voltage: 200 Vdc, max. (SD-TRM) Current: 0.5 A, max. Compatible SuperDuct conventional detectors two-wire and Signature duct smoke detectors Operating -4°F to 158°F (-20°C to environment 70°C) Humidity: 93% RH, noncondensing Storage temperature -4 to 140 °F (-20 to 60 °C) Agency listings UL, ULC, MEA, CSFM Ordering Information Catalog Number Description Ship Wt., lb. (kg) SIGA-SD Intelligent SuperDuct Detector 2.4 (1.1) Accessories SD-T8 8-inch sampling tube 0.5 (0.2) SD-Ti 8 18-inch sampling tube 1.5 (0.7) SD-T24 24-inch sampling tube 2.7 (1.2) SD-T36 36-inch sampling tube 3.0 (1.4) SD-T42 42-inch sampling tube 3.5(l.6) SD-T60 60-inch sampling tube 5.8 (2.6) SD-T78 78-inch sampling tube 7,5 (3.4) SD-Ti 20 120-inch sampling tube 11.5 (5.2) SD-PH Protective housing for high humidity environments 5.5 (2.5) SIGA-LED Remote alarm LED 1.0(0.5) SD-TRM Remote test station, magnetic 1,0 (0.5) SD-TRK Remote test station, keyed 1.0 (0.5) SD-VTK Air velocity test kit (stoppers only, etc) 1.0(0.5) SD-GSK Cover gasket kit 0.5 (0.2) SD-MAG Test magnet kit 0.5 (0.2) SIGA-SDPCB Replacement PCB/Signature sensor kit 1.0 (0.5) Page 4of4 DATA SHEET E850010584 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1657:0223 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models ESD-SJ, ESD-ST, TSD-SJ, TSD-ST, TSD-SJG, TSD-SJCO2, TSD-STCO2, SIGA-SD, SD-2W, ESD-2W, E-PDD, and FX-PDD photoelectric type duct smoke detectors. The duct detector consists of a thermoplastic enclosure, recognized component printed wiring board, a listed duct detector subassembly, and an inlet coupling tube and an exhaust tube along with gaskets. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15.2-19.95 VDC 16-30 VDC: SD-2W, ESD-2W INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type, duct smoke detectors for use with separately listed compatible fire alarm control units in conjunction with Models ESD-CJ, -CT or TSD-CJ, -CT series duct smoke detector controller (CSFM Listing No. 3240-1657:225). Models SIGA-SD, E-PDD, FX-PDD, SD-2W or ESD-2W does not require a listed duct smoke detector controller. Suitable for use in ducts where air velocity is between 100 and 4000 ft/mm. *Models ESD-SJ, ESD-ST, TSD-SJ, TSD-SJG, TSD-SJCO2, SlGA-SD, SD-2W and ESD-2W are suitable for use in ambient temperatures of -4°F to 158°F. Refer to listee's Installation Instruction Manual for details. NOTE: 1. CO2 sensing features were not examined. 2. Formerly 3242-1591:223 *Corrected 3-22-13 BH This listing is based upon technical data submitted the test results and/or other data but does not by the applicant. CSFM Fire make an independent verification Engineering staff of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division