Loading...
HomeMy WebLinkAbout3193 LIONSHEAD AVE; ; FPC2019-0117; PermitPERMIT REPORT CL'City of Carlsbad Print Date: 10/28/2021 Job Address: 3193 LIONSHEAD AyE, CARLSBAD, CA 92010-4702 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2218801600 Track #: Valuation: $231,387.25 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: SPEC SUITE- SPRINKLER TI (39 HEADS) Permit No: FPC2019-0117 Status: Closed - Finaled Applied: 05/21/2019 Issued: 05/30/2019 Finaled Close Out: 09/25/2019 Inspector: Final Inspection: FPContractor: INDUSTRIAL FIRE SPRINKLER CO INC 3845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 (619) 266-6030 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Project Name: Drawing 1 Location: Drawing Name: CALC MODEL Design Remote Area Number: Remote Area Location: Occupancy Classification: Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: In-rack Demand: Hose Streams: Hydraulic Calculations for REMOTE AREA #1 Light Hazard Calculation Date: Date: 5/21/2019 0.1ogpm/ft2 1 500ft2 (Actual 939ft2) 130ft2 Upright 10 N/A gpm at Node: N/A 250.00 at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 425.34 @73.525 Type of System: Volume of Dry or PreAction System: N/A Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes FPC20I9-0117 3193 LIONSHEAD AVE SPEC SUITE- SPRINKLER TI (22 HEADS) 2218801600 5/21/2019 FPC20I9-0117 1© M.E.P.CAD, Inc. AutoSPRlNK 2018 04.3.10.0 5/21/2019 8:39:38AM Page 1 6000 200 18(j i 4800 5400 2400 3600 3000 4200 Flow - gpm Date: 5/21/2019 135 120 105 ID 0 75 1:1 60 30 15 Job Name: Drawingi Remote Area Number: 150- Availabe Supply - Static Pressure 132.000 Water Supply Summary Sheet Node: I 2975.00 '425.34 @ 131.973 @ 131.000 (90%) - Static Pressure 118.800 (90%)--9Th11 -p 175.34 425.34 c1- 73.525. with Hose Allowance at Source System demand curve fflUiLJiLWIIIIII 111111111 111111111 111111111 111111CC I III I I I C I I I I I I I I C I I I I I I I I I I I Hydraulic Graph N 185 (©M.E.P.CAD, Inc. RA AutoSPRlNK2018v14.3.10.0 5/21/2019 8:39:39AM Page 2 111 ISummary Of Outfiowing Devices Job Number: 1 Reoort Descriotion: Liaht Hazard Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 204 16.03 13.00 5.6 8.194 Sprinkler 205 15.51 13.00 5.6 7.669 Sprinkler 210 15.60 15.00 5.6 7.756 Sprinkler 211 18.42 15.00 5.6 10.824 Sprinkler 212 15.00 15.00 5.6 7.175 Sprinkler 218 18.99 15.00 5.6 11.505 Sprinkler 219 19.05 15.00 5.6 11.572 Sprinkler 220 19.25 15.00 5.6 11.817 Sprinkler 221 1 18.87 15.00 5.6 11.359 Sprinkler 222 1 18.61 15.00 5.6 11.044 r Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. AutoSPRINK 2018 04.3.10.0 5/21/2019 8:39:41AM Page 3 Job Name: Drawing 1 Remote Area Number: Date: 5/21/2019 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 132.000 131.000 2975.00 131.973 425.34 73.525 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -35-6 Supply 73.525 175.34 204 10-0 Sprinkler 8.194 16.03 205 10-0 Sprinkler 7.669 15.51 210 13-6 Sprinkler 7.756 15.60 211 13-6 Sprinkler 10.824 18.42 212 13-6 Sprinkler 7.175 15.00 218 13-6 Sprinkler 11.505 18.99 219 13-6 Sprinkler 11.572 19.05 220 13-6 Sprinkler 11.817 19.25 221 13-6 Sprinkler 11.359 18.87 222 13-6 Sprinkler 11.044 18.61 5 4-6 58.281 7 -1-6 58.764 8 4-6 58.295 9 3-6 56.570 10 -1-6 58.753 11 3-6 56.577 13 25-0 46.950 16 25-0 45.789 ,© M.E.P.CAD, Inc. AutoSPRlNK 2018 v14.3: 5/21/2019 8:39:44AM Page 4 Job Name: Drawing 1 Remote Area Number: Date: 5/2112019 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 24 25-0 46.951 27 25-0 45.783 32 13-6 8.249 34 13-6 7.630 52 25-0 46.951 55 25-0 45.776 69 12-4 13.776 72 12-4 13.700 74 12-4 14.054 76 12-4 14.152 77 12-4 16.303 78 12-4 13.596 79 12-4 13.533 81 12-4 13.175 82 12-4 13.186 87 25-0 46.953 90 25-0 45.763 92 25-0 45.755 97 25-0 46.957 100 25-0 45.769 102 25-0 46.961 105 25-0 45.783 107 25-0 46.968 ,© M.E.P.CAD, Inc. MlAutoSPRINK 2018 v14.3. 5/21/2019 8:39:44AM Paqe 5 Job Name: Drawing I Remote Area Number: Date: 5/2112019 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 110 25-0 45.789 112 25-0 46.977 115 25-0 45.796 127 3-6 56.569 © M.E.P.CAD, Inc. AutoSPRlNK 2018 v14.3. 5/21/2019 8:39:44AM Page 6 Job Name: Drawing I Remote Area Number: Date: 5/21/2019 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a nQJ'tivQ ____________________ vp1u9. __ Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 212 13-6 5.6 15.00 1 (See Notes) 0-11% 120 7.175 ••••• Route l•••'• Sprinkler, T(5-0) 5-0 0.076427 34 13-6 15.00 1.0490 5-11% 0.455 34 13-6 15.51 1 (See Notes) 8'9 120 7.630 Flow (q) from Route 3 2E(2-0), P0(5-U) 9-0 0.284207 0.506 82 12-4 30.51 1.0490 17-9 5.050 82 12-4 18.61 1% 5-0% 120 13.186 Flow (q) from Route 6 0.068813 79 12-4 49.12 1.6820 0.347 79 12'4 18.87 11/2 0-6 120 13.533 Flow (q) from Route 7 0.125579 78 12-4 67.99 1.6820 0-6 0.063 78 12-4 18.42 11/2 (See Notes) 3-11 120 13.596 Flow (q) from Route 5 T(9'-1 1) 91-11 0.195692 77 12-4 86.42 1.6820 13-10 2.707 77 12-4 88.92 1½ (See Notes) 28-5 120 16.303 Flow (q) from Route 2 2E(4'-l1%), T(9'-l1) 19-9% 0.724507 -5.491 92 25-0 175.34 1.6820 48-3 34.944 92 25-0 4 681/2 120 45.755 0.002177 100 25-0 87.68 4.2600 6-8% 0.015 100 25-0 2 (See Notes) 181'0 120 45.769 P0(10-0) 2E(5'-O), P0(10-U) 30-0 0.005626 97 25-0 21.83 2.0670 211-0 1.187 97 25-0 87.65 6 10-6 120 46.957 Flow (q) from Route 13 0.000467 102 25-0 109.48 6.3570 10-6 0.005 102 25'0 21.75 6 10-6 120 46.961 Flow (q) from Route 16 0.000653 107 25-0 131.23 6.3570 10-6 0.007 107 25-0 21.75 6 10-6 120 46.968 Flow (q) from Route 11 0.000868 112 25-0 152.98 6.3570 10-6 0.009 ,©M.E.P.CAD, Inc. AutoSPRlNK2O18v14.3.1O.O 5/21/2019 8:39:47AM Page 7 Job Name: Drawing 1 Remote Area Number: Date: 5/21/2019 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as ne3'tive vake. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) 112 25-0 22.36 6 (See Notes) 816 120 46.977 Flow (q) from Route 12 5E(17-7), CV(40'-3), BV(12'-7) 140-10 0.001117 11.055 5 -0-6 175.34 6.3570 222-4 0.248 5 -0-6 1 8 : Notes) (See 35'0 140 58.281 E(30-61/2) 30'-6Y2 0.000217 8 -0-6 175.34 8.3900 65-6% 0.014 8 -0-6 8 (See Notes) 4'0 120 58.295 E(21'-11/2) 21-1% 0.000314 -1.734 127 3'-6 175.34 8.2490 25-1 1/2 0.008 127 3-6 8 (See Notes) 4'0 140 56.569 BFP 0.000236 9 3'-6 175.34 8.2490 4-0 0.001 9 3'-6 8 (See Notes) 3'-6 140 56.570 E(30'-6%) 30-6% 0.000217 11 3-6 175.34 8.3900 34-0% 0.007 11 3-6 8 (See Notes) 50 120 56.577 E(21-1%) 21-1% 0.000314 2.168 10 -1-6 175.34 8.2490 26-1 % 0.008 10 -1-6 8 (See Notes) 20'0 140 58.753 E(30'-6%) 30-61/2 0.000217 7 -1-6 175.34 8.3900 50-6% 0.011 7 -1-6 12 (See Notes) 5272 140 58.764 3E(44'-3), EE(21-3%), S 154-0 0.000032 14.740 1 -35'-6 175.34 12.4600 681-2 0.022 250.00 73.525 Hose Allowance At Source Total(Pt) Route 1 1 425.34 210 13-6 5.6 15.60 1 (See Notes) 1-0 120 7.756 '••Route2•••• Sprinkler, T(5-0) 5-0 0.082136 32 13-6 15.60 1.0490 6-0 0.493 32 13-6 16.03 1 (See Notes) 8'-9 120 8.249 Flow (q) from Route 4 2E(2'-O), P0(5-0) 9-0 0.303774 0.506 76 12-4 31.63 1.0490 17-9 5.397 ©M.E.P.CAD, Inc. AutoSPRlNK2O18v14.3.1O.O 5/21/2019 8:39:47AM Page Job Name: Drawingi Remote Area Number: Date: 5/21/2019 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative vaIu. Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 76 12-4 57.30 11/2 (See Notes) 061/2 120 14.152 Flow (q) from Route 8 T(9'-l1) 91-11 0.206318 77 12-4 88.92 1.6820 10-5 2.151 16.303 Total(Pt) Route 2 205 101-0 5.6 15.51 1 (See Notes) 1621,4 120 7.669 ••••• Route 3 ..... Sprinkler, E(2'-O) 2-0 0.081281 -1.517 34 13-6 15.51 1.0490 1821/2 1.479 7.630 Total(Pt) Route 3 204 10.-0 5.6 16.03 1 (See Notes) 16-2% 120 8.194 ••••• Route 4'•' Sprinkler, E(2'-0) 2-0 0.086418 -1.517 32 13-6 16.03 1.0490 1821/2 1.572 8.249 Total(Pt) Route 4 211 13-6 5.6 18.42 1 (See Notes) 9-3 120 10.824 ••"• Route 5••••• Sprinkler, 3E(2'-O), P0(5-U) 111-0 0.111800 0.506 78 12-4 18.42 1.0490 20-3 2.266 13.596 Total(Pt) Route 5 222 13-6 5.6 18.61 1 (See Notes) 7-3% 120 11.044 Route 6. Sprinkler, E(2'-O), P0(5-U) 7-0 0.113895 0.506 81 12-4 18.61 1.0490 14-3% 1.625 81 12-4 1% 0-11% 120 13.175 0.011426 82 12-4 18.61 1.6820 0-11% 0.011 13.186 Total(Pt) Route 6 221 13-6 5.6 18.87 1 (See Notes) 7-3% 120 11.359 ••• Route 7 Sprinkler, E(2'-U), P0(5-0) 7-0 0.116898 0.506 79 12-4 18.87 1.0490 14-3% 1 669 13.533 Total(Pt) Route 7 218 13-6 5.6 18.99 1 (See Notes) 7'31/2 120 11.505 ••••• Route 8•••• Sprinkler, E(2'-U), P0(5-U) 7-0 0.118287 0.506 72 12-4 18.99 1.0490 14-3% 1.689 72 12-4 11/2 6-51/2 120 13.700 0.011867 69 12-4 18.99 1.6820 6-5% 0.077 CM/ ©M.E.P.CAD, Inc. AutoSPRlNK2O18v14.3.1O.O 5/21/2019 8:39:47AM Page Job Name: Drawingi Remote Area Number: Date: 5/21/2019 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as a negative v'I"e. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 69 12-4 19.05 11/2 651/2 120 13.776 Flow (q) from Route 9 0.042896 74 12 -4 38.04 1.6820 651/2 0.278 74 12-4 19.25 11/2 1,-1 120 14.054 Flow (q) from Route 10 0.091495 76 12-4 57.30 1.6820 1-1 0.097 14.152 Total(Pt) Route 8 219 13-6 5.6 19.05 1 (See Notes) 7-3% 120 11.572 ••••• Route 9 ..... Sprinkler, E(2'-O), P0(5-U) 7-0 0.118926 0.506 69 12-4 19.05 1.0490 14-3% 1.699 13.776 Total(Pt) Route 9 220 13-6 5.6 19.25 1 (See Notes) 731, 120 11.817 ••••• Route 10•••• Sprinkler, E(2'-O), P0(5-0) 7-0 0.121257 0.506 74 12-4 19.25 1.0490 1431/2 1.731 14.054 Total(Pt) Route 10 110 25-0 44.11 2 (See Notes) 181-0 120 45.789 "" Route ll"" P0(10-0), Flow (q) from Route 20 2E(5'-O), P0(10-0) 30-0 107 25-0 21.75 2.0670 211-0 0.005588 1.179 46.968 Total(Pt) Route 11 110 25-0 44.11 4 (See Notes) 10'6 120 45.789 ••••• Route 12••• Flow (q) from Route 20 P0(26-4) 26-4 0.000174 115 25-0 22.36 4.2600 36-10 0.006 115 25-0 2 (See Notes) 181'0 120 45.796 2E(5'-O), P0(10-0) 20-0 0.005879 112 25-0 22.36 2.0670 201-0 1.182 46.977 Total(Pt) Route 12 24 25-0 22.45 + 21.64 6 10-6 120 46.951 ••••• Route 13•'••• Flow (q) from Route 15 and 18 ________ 0.000087 52 25-0 44.08 6.3570 10-6 0.001 52 25-0 21.71 6 10-6 120 46.951 Flow (q) from Route 17 0.000182 87 25-0 65.79 6.3570 10-6 0.002 ,©M.E.P.CAD, Inc. AutoSPRINK2O18v14.3.1O.O 5/21/2019 8:39:47AM Page 10 Job Name: Drawingi Remote Area Number: Date: 5/21/2019 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nj'tive valuQ. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 87 25 -0 21.86 6 1 10 -6 120 46.953 Flow (q) from Route 14 f 0.000310 97 25-0 87.65 6.3570 10-6 0.003 46.957 Total(Pt) Route 13 92 25-0 87.68 4 391 120 45.755 •• ... Route 14 Flow (q) from Route 1 0.002175 90 25-0 87.65 4.2600 3-9% 0.008 90 25-0 2 (See Notes) 181'0 120 45.763 P0(1 0-U) 2E(5'-0), P0(10-0) 30-0 0.005641 87 25-0 21.86 2.0670 211-0 1.190 46.953 Total(Pt) Route 14 13 25-0 22.45 6 10-6 120 46.950 ••••• Route 15•'••• Flow (q) from Route 19 0.000025 24 25-0 22.45 6.3570 10-6 0.000 46.951 Total(Pt) Route 15 100 25-0 21.83 4 10-6 120 45.769 ' ... Route 16"" Flow (q) from Route 1 0.001282 105 25-0 65.85 4.2600 10-6 0.013 105 25-0 2 (See Notes) 181'0 120 45.783 P0(10-0) 2E(5'-O), P0(10-0) 30-0 0.005586 102 25-0 21.75 2.0670 211-0 1.179 46.961 Total(Pt) Route 16 90 25-0 21.86 4 10-6 120 45.763 •••••Route 17'•••• Flow (q) from Route 14 0.001279 55 25-0 65.79 4.2600 10-6 0.013 55 25-0 2 (See Notes) 181'0 120 45.776 P0(10-0) 2E(5'-O), P0(10-0) 30-0 0.005568 52 25-0 21.71 2.0670 211-0 1.175 46.951 Total(Pt) Route 17 55 25-0 21.71 4 10-6 120 45.776 ••''• Route 18••••• Flow (q) from Route 17 0.000610 27 25-0 44.08 4.2600 10-6 0.006 &.,©M.E.P.CAD, Inc. AutoSPRlNK2018v14.310.0 5/21/2019 8:39:47AM Page 11 Job Name: Drawingi Remote Area Number: Date: 5/21/2019 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value __ Fitting (Foot) P1 Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 27 25-0 2 (See Notes) 1 [ 181'-0 120 45.783 P0(10-0) 2E(5-0), P0(10-U) f 30-0 0.005534 24 25-0 21.64 2.0670 211-0 1.168 46.951 Total(Pt) Route 18 27 25-0 21.64 4 (See Notes) 10'6 120 45.783 ••••• Route 19 Flow (q) from Route 18 P0(26-4) 26-4 0.000175 16 25-0 22.45 4.2600 36-10 0.006 16 25-0 2 (See Notes) 1811 0 120 45.789 3E(5-0) 15-0 0.005923 13 25-0 22.45 2.0670 1 96-0 1.161 46.950 Total(Pt) Route 19 105 25-0 21.75 4 10-6 120 45.783 ••'•• Route 20..... Flow (q) from Route 16 0.000611 110 25-0 L4.11 4.2600 10-6 0.006 45.789 Total(Pt) Route 20 ,©M.E.P.CAD, Inc. AutoSPRINK2018v14.3.10.0 5/21/2019 8:39:47AM Page 12 Job Name: Drawing 1 Remote Area Number: Date: 5/21/2019 [valent Pipe Lengths of Valves and Fittings (C=120 only) I IC Value Multiplier I Actual .. 4 Factor .87 Value OfC 100 130 140 150 I = Schedule 40 Steel Pipe Inside Diameter) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/40 Elbow Ee2 221/20 Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 900 FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 1,©M.E.P.CAD, Inc. AutoSPRlNK2018v14.3.10.0 5/21/2019 8:39:46AM Page 13 FfC2d9''oII1. Page 1 of 6 NIIUNG* a MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatingscan be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 [J VdS Approved: Certificates G414009 and G414010 (P4) LPCB Approved CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar) Approvals ONLY is 5 psi (0.35 bar). Material Standards: FPC2O19Mfl7 3193 UONSHEAD AVE SPEC SUITE- SPRINKLER TI t,2HEADSI The minimum operating pressure for LPCB and CE Frame Casting: Brass UNS-C84400 or QM Brass 221 8801600 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 5/2112019 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tap F PC2O 1 9-01 1 7 Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-NV, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F033314 17.06.02 Rev 17.1 Replaces Form No. F_033314 Rev 16.4 (Added PN for CCCF approved sprinkler.) Page 2 of 6 N41KJNG4®R MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 10896W/13 (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler VEMa Wrench Flat Clip Protective Sprinkler Cap W M ==1089=6=O Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 17.06.02 Rev 17.1 Page 3 of 6 MICROFAST® QUICK N41KJNG*® l'lII[7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color U o or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes l The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 11 Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 112" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17.06.02 Rev 17.1 Page 4 of 6 NJIKJNG4 ® MICROFAST® QUICK nu.yAwA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) r1T'.. Temperature KEY The Viking Microfast Quick Response Pendent Sprinkler VK302 LAIx 4— Escutcheon (iuppFicuhFe) Maximum 175 PSI(12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN K-Factor Length (Refer also to Design Criteria.) tye Number' NPT BSP U.S. metric' Inches mm cULus' VdS LPCB (E 1 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, 02, C2X Al A1Z, B1Y D1Z, C1Y -- 19780 VK302 Pendent 1/2" -- 56 80.6 2-1/4 58 -- -- -- -- -- 03 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 NOTICE - tIT1Below Availability (Contact 7ILocal I•JIILj 06662B VK302 Pendent 1/2' 15 mm 56 80.6 2-1/4 58 A1Z, B1Y, 02, C2X I -- -- -- -- 18021 VK302 Pendent 1 1/2" 15 mm 1 5.6 1 80.6 1 2-1/4 58 AiX, B1Y Al I AiX, B1Y I Dlx, C1Y8 I D1X, C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 °C), 286 °F (141 °C) Polyester 56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter56 V - Standard surface-mounted escutcheon or the (79 °C), and 200 °F (93 °C) 2 - ENT5 Viking Microfast Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 "F (68 °C), 175 °F (79 °C), and 3-Chrome maticO Model E-1, E-2, or E-3 Recessed Escutcheon 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the D - 155 °F (68 °C), 175 °F (79 °C), 200°F Viking Microfast Model F-i Adjustable Escutcheon (93 °C), 286°F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 10E Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008 DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, Designed for use in Light and Ordinary occupancies, The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.06.02 Rev 17.1 Page 5 of 6 MICROFAST® QUICK N4 IIJFs1G1 l:II[.u.rM RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) The Viking Microfast Quick Response Temperature KEY Pendent Sprinkler VK302 A1X4—Esculche pplJc2he) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 15mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 711ZAvailability Local Viking Office) 06662B VK302 Pendent 1/2' 15 mm 1 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 1 15 mm 1 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings x - Standard surface-mounted escutcheon or the A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F Viking Micromatic® Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B - 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1 -Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester' Viking Microfast Model F-i Adjustable Escutcheon, C - 155 °F (68 "C) 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-I Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA FM (Alsb refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 17.06.02 Rev 17.1 2-I/8".. T (54 mm) 1 3/4" Tj1 (45 mm) Max. 1-1/8" 1 ,,, c u (29 mm) (51mm) Max (54 mm) 1-1/8" (29 mm) Mm. Page 6 of 6 N4 I KJ N G*®R MICROFAST@ QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1/2" (15 mm) N PT 2-1/4" (57 mm) Installed with a standard 1/8" surface-mounted escutcheon Ceiling Opening Size: 1 2-5/16" (59 mm) minimum J-2 2-1/2" (64 mm) maximum T(38 2" mm) (51 mm) Mm. Max. Installed with a Microfast Note: At maximum, adapter Model F-I Adjustable is exposed 1/2" (13 mm) Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F033314 17.06.02 Rev 17.1 Replaces Form No. F_033314 Rev 16.4 (Added PN for CCCF approved sprinkler.) Page 1 of 4 "ii I I(IFS1G® MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector: Brass UNS-C23000 or Copper UNS-C19500 The Viking Corporation's Web site at Bulb: Glass, nominal 3 mm diameter http://www.vikinggroupinc.com. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent PTFE Tape Screw: Brass UNS-C36000 edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-IW, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 Rev 15.2 Page 2 of 4 'I I (II1G® MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 C) Orange Ordinary 155 °F (68 °C) 100 F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 F (93 C) 150 °F (65 °C) Green High 286 °F (141 C) 225 ¶ (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Form No. F052114 Rev 15.2 Page 3 of 4 NIVI K I13® MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I (UL) Temperature KEY Microfast Quick Response Upright Sprinkler VK300 Al X I I Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Number SIN NPT BSP U.S. metric2 Inches mm cULus VdS LPCB NYC-CE 12978 VK300 11 1/2" 15 mm 5.6 80.6 2-36 56 Al, B2 -- -- See footnote 7. NOTICE • II:7f Inrñ rF71!r,y1 • • - vrnrj I .Jilr Product 06661B VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 -- -- See footnote 7.1 -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200°F (93 °C), and 1 - Brass, Chrome, White Polyester5'6, and Black Polyester5'6 / 2-ENT6 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Cbir( 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 Rev 15.2 a Page 4of4 N IKJI1G® MICROFAST® QUICK Iil:IIEu.7M.. RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY -- Finish Microfastm Quick Response Txi heon (t appticable) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 NOTICE - ProduclBelow Availability (ContactLocalViking r'J# 06661B VK300 1 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 - Brass, Chrome, White Polyester5, and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Pcyester 2 - Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 Rev 15.2