HomeMy WebLinkAbout2819 LOKER AVE E; ; FPC2019-0275; PermitC(cityof PERMIT REPORT Carlsbad Print Date: 12/08/2020 Permit No: FPC2019-0275 Job Address: 2819 LOKER AVE E, CARLSBAD, CA 92010-6626 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090831600 Track #: Applied: 12/12/2019 Valuation: $98,694.22 Lot #: Issued: 12/23/2019 Occupancy Group: Project #: Finaled Close Out: 01/27/2020 #f Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Inspector: Plan Check 4*: Final Inspection: Project Title: Description: ACUSHNET - 2ND FLR SPRINKLER TI (24 HEADS) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: 1 $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 4 FC210 ( 1ulletin 120 August 2019 — Model G/171Reliable Recessed Automahc Sprinkler Features Highly decorative and adjustable recessed pendent sprinkler. Rapid and easy installation. Compensating angular ceiling alignment 3/4" (19mm) Adjustment to flush pendent position. 5 1/2" (13mm) Adjustment for recessed position with 1/4" (6mm) minimum recess. 6. Various finishes available to match any decor. Listings and Approvals Underwriters Laboratories Inc. (UL) Underwriters' Laboratories of Canada (ULC) NYC BS&A No. 587-75-SA Loss Prevention Council (LPC, UK) XLH, OHI and OHII Occupancies Only Note: Unless otherwise indicated, approvals are ordinary hazard without limitations. Small orifice sprinklers are lim- ited to light hazard occupancies. Product Description Attractively versatile is the description for the Reliable Model GIF1 Recessed Automatic Sprinkler. The Model GIF1 Recessed Sprinkler facilitates a rapid and perfect installation. When this sprinkler is used in place of any standard pendent sprinkler a more attractive and easier installation is the result. The Model C/Fl Recessed escutcheon is highly ad- justable. The two piece construction makes field instal- lation a very easy and rapid task. The escutcheon collar threads onto the sprinkler inlet end and the sprinkler and collar are easily installed into the drop nipple using the Model RC1 Sprinkler Wrench. The escutcheon sleeve is then simply pushed onto the collar after the ceiling panels are installed. This also allows the ceiling panels to later be removed without shutting down the sprinkler system protection, thus facilitating maintenance of above ceiling services. The impressively large adjustment in the escutcheon eliminates the expense of re-cutting drop nipples as is necessary with the non—adjustable pendent sprinklers. This recessed sprinkler's small profile does not disrupt the overhead aesthetics, and yet one glance upward gives visual assurance of the finest in fire protection and decorative appearance of an automatic sprinkler system. The Reliable Model C Automatic Sprinkler is the heart of the Model G/F1 Recessed Sprinkler. This sprinkler utilizes the center strut solder in compression principle of con- struction. The fusible alloy, captured in the cylinder of a small solder capsule by a stainless steel ball, acts as the trigger of the sprinkler. When the fusible alloys melts, the sprinkler's operating parts spring free from the sprinkler clearing the waterway and allowing the deflector to dis- tribute the discharging water. Reliable sprinklers should be installed in accordance with the standards of the government body or Authority Having Jurisdiction. The sprinklers must also be installed with the Model RC1 Sprinkler Wrench, specifically de- signed by Reliable for use with these sprinklers. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation Data: Orifice Size Nominal K Factor Thread Height Approvals Sprinkler Identification US Metric Number (SIN) 1/2 (15mm) 5.6 80 ½' NPT (R ½) 2/" (73mm) UL, ULC, BS&A, LPC UK R1015 7Ae"(llMM) 4.2 60 ½" NPT (R ½) 21/8" (73mm) UL, ULC, BS&A, R1013 3/s" (9.5mm) 2.8 40 ½" NPT (A ½) 2f8" (73mm) UL, ULC, BS&A, R1011 17/32" (13.5mm) 8.0 115 3/4" NPT (R3/4) 215/16" (74.5mm) UL, ULC R1017 Standard Finishes Sprinkler Escutcheon Bronze Brass Plated Chrome Plated Chrome Plated White Polyester Coated(') White Painted (1) Only frame and deflector are coated, operating parts are chrome plated. UL Listed and BS&A Approved only. Temperature Ratings Ordering Information Temperature rating Sprinkler finish Escutcheon finish Orifice size Inlet thread Note: Sprinkler and escutcheon are packaged sepa- rately. Other finishes and colors are available on special order, consult factory for details. Sprinkler Frame Maximum Classification Temperature Color Ambient Temperature OF °C (As Required) OF °C Ordinary 135 57 Uncolored 100 38 Ordinary 165 74 Uncolored 100 38 Intermediate 212 100 White 150 66 - 7 75/76D14- 71/RN COLLAR UN71L ____ REDUCER BOHE AGMNSC SPRINKLER WRENCH BOSS. ------77 I / I / 2 l/4 0/A I RECOMMENDED CEILING HOLE 0/7. )IT - 3/4 00 Vèl 75/76 ADJUSTMENT (2) 7 7/76(3) I2OFGO IA 2 27/J2 0/A Maintenance Model G!F1 Recessed Sprinklers® should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprin- klers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. (2) A recessed sprinkler installed directly into a tee reduces the adjustment of the escutcheon. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address eRecycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 08/19 P/N 99999700013 FfL,2o 19 O27S BE 4077 Airpark Dr. Standish, Ml 48658 • 989-846-4583 www.globesprinkler.com GLI Technical Support 989-414-2600 techserviceglobesprinkler.com SPRINKLER SERIES GL-QR/INCH STANDARD COVERAGE, QUICK RESPONSE* THE INCH® FLAT PLATE CONCEALED PENDENT K-FACTOR 5.6 GENERAL DESCRIPTION The Globe Series GL-QR/INCH sprinklers are Listed Quick Response concealed sprinklers which utilize a 3mm fran- gible glass bulb as the thermosensitive operating element. They are Listed and Approved as Standard Coverage sprinklers and are to be installed in accordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13). While providing the optimal aesthetic appeal with the low profile flat cover plate, the GL-QRIINCH additionally provides the largest vertical adjustment in the industry of a nominal 1". This nominal 1" adjustment allows for previously unrecognized installation flexibility resulting in a clean and tight final "fit" to the ceiling. The sprinkler is available in four temperatures and the cover plate is available in two temperatures. Additionally, the cov- er plate is available in three diameters. The GL-QRIINCH sprinklers are shipped with a protective cap which is tem- porararily removed during initial installation and replaced to protect against ceiling installation damage. The protective cap is removed and the flat cover plate is installed when the system is ready for service, See "Installation" steps within this document. OPERATION The soldered cover plate drops off the retainer assembly when exposed to heat, as from a fire, that has reached the plate's Listed temperature rating exposing the sprinkler above. Upon the releasing of the cover plate, the deflector, which is connected to two guide pins, drops down below the ceiling into its intended position. As heat encompasses the glass bulb operating element of the sprinkler, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid expansion causes breakage of the glass bulb, resulting in release of the water seat assembly, and discharge of water from the sprinkler. FINISHES AND ACCESSORIES Flat Plate Finishes Chrome White Painted • Black Painted Other finishes - special order NOTE: Factory painted cover plates must not be repainted. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Wrench P/N 332765 SEP 2019 (T) 3-5116" DIAMETER 2-3/4" DIAMETER COVER PLATE COVER PLATE 4-1/2" DIAMETER COVER PLATE SEISMIC IBC/ASCE/SEI CODES TECHNICAL DATA SIN GL5606 Approvals cULus Listed *FM approved for Standard Response only Maximum Working Pressure 175 psi (l2bar) Factory tested to 500 psi (34 bar) Minimum Operating Pressure * 7 psi (48 kPa) Temperature Ratings 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate Materials of Construction Frame - bronze Deflector - brass . Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloys Seal - teflon Drop Pin -stainless steel Bulb - glass with alcohol based solution, 3mm Escutcheon Assembly - carbon steel NOTE: Users should refer to Globe's web site (www.globesprinkler.com) to ensure that the most recent technical literature is being utilized. PAGE 1 OF 4 GFS-1 05 INSTALLATION CARE AND MAINTENANCE NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak- age. It is recommended not to exceed 14 ft-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads. Step 1. Sprinklers must be properly oriented. Step 2. Remove the Protective Cap. Step 3. With pipe-thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Note: Do not grasp the sprin- kler by the deflector. Step 4. Wrench-tighten the sprinkler only using the concealed wrench P/N 332765. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex. Note: Do not apply wrench to frame arms. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent damage to the Deflector and Drop Pins during ceiling installation and/or during application of the finish coating of the ceiling. NOTICE: The system is considered Out of Service when the protective caps are in place. Step 6. After the ceiling has been completed, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged or the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. Thread on the Concealed Plate Assembly. NOTE: As a convenience, either the Hand Held Installation Tool (P/N 332875) or the Extension Installation Tool (P/N 332876) may be used during the above installation proce- dure. Refer to GFS-860 for information on The INCH® installation tools. Prior to installation, it is important to read and follow "The INCH® Sprinkler Caution" sheet (GFS-855) included within each box of sprinklers. This sheet is available on Globe's web site (www.g lobes p ri n kler.co m). Always obtain permission from the proper authorities to shut down the affected fire protection system and notify all personnel who may be affected by this action before closing a fire protection system main control valve for maintenance work on the system that it controls. Sprinklers should only be cleaned by means of gently dusting with a feather dust- er; otherwise, non-operation in the event of a fire or inadver- tent operation may result. When properly installed, there is a nominal 1/8" (3mm) air gap between the Cover Plate and the ceiling (FIGURE 1). This air gap is necessary for proper operation of the sprin- kler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. This annular "gap" must be maintained and should never be sealed or caulked. Factory painted Cover Plates must not be repainted. In accordance with NFPA 25, Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Care must be exercised to avoid damage to the sprinklers— before, during, and after installation. Sprinklers damaged by dropping, striking, wrench slippage, or similar incidents, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g. NFPA 25), in addition to the standards of any other authorities having jurisdiction. SEP2019 GFS-105 PAGE 2OF4 21/4" DIA. MIN. HOLE IN CEILING -1718"DIA. - l"x 1/2" REDUCER 21/4'DIA.MIN. HOLE IN CEILING -1 7/8" DIA. 1"xl/2" REDUCER MAX. CUP 17/8" M IN. SUPPORT 1 7/8 MIN. DROP PIN PIN CUP DEFL 23/4"MA( ECTOR -DEFLECTOR SUPPORT SHELL CEILING 2314" DIA, CEILING 3 5;16" DIA. FLAT COVER PLATE k-FLAT COVER PLATE FIGURE 1: GL-QRIINCH INSTALLATION DIMENSIONS -37/8-4" DIA. MIN. --. HOLE IN CEILING REDUCER ____ CUP-- SUPPORT SHELL DEFLECTOR-, 2 3/4' MAX. DROP PIN 17/8' MIN. CEILING - ] 4 1/2' DIA. CEILING COVER PLATE FIGURE 2: GL-QRIINCH SEISMIC ESCUTCHEON INSTALLATION DIMENSIONS Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E ------------ I I I I \ / DEFLECTOR DROP PIN CEILING 1 114' MAX. 1/4 MIN. FIGURE 3: GL-QR!INCH ACTIVATED POSITION SEP 2019 GFS-105 PAGE 3 OF 4 FIGURE 4: HAND HELD INSTALLATION TOOL P/N 332875 FIGURE 5: INSTALLATION TOOL USED WITH EXTENSION PIN 332876 FIGURE 6: PROTECTIVE CAP P/N 332870 TABLE A: COVER PLATE PART NUMBERS FLAT COVER WHITE WHITE CHROME CHROME BLACK BLACK CUSTOM CUSTOM PLATE SIZES 135°F (57°C) 155°F (68°C) 135°F (57°C) 155°F (68°C) 135°F (57°C) 155°F (68°C) 135°F (57°C) 155°F (68°C) 2 3/4" DIA. 332726 332731 332724 332729 332726-B 332731-B 332727 332732 3 5/16" DIA. 332706 332711 332704 332709 332706-B 332711-B 332707 332712 332822 332828 332821 332827 332822-B 332828-B 332823 332829 ORDERING INFORMATION SPECIFY SPRINKLER Quantity SIN Temperature Rating Finish Part Number GL5606 SPRINKLERS PART NUMBER 135°F (57°C) ....................560613501 155°F (68°C) ....................560615501 175°F (79°C) ....................560617501 200°F (93°C) ....................560620001 COVER PLATES SEE TABLE A WRENCH Quantity• Part Number 332765 INSTALLATION TOOL Quantity ° Part Number Handheld ......................332875 Used with Extension ................332876 PROTECTIVE CAP Quantity• Part Number 332870 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). FIGURE 7: CONCEALED WRENCH P/N 332765 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support. 989-414-2600 • techservicegIobesprinkIer.com &)— SEP 2019 GFS-105 PAGE 4OF4 fl7c2_0 9 -02_5' GL4) E 4077 Airpark Dr. Standish, MI 48658 989-846-4583 www.globesprinkler.com Technical Support . 989-414-2600 techservicoglobesprinkIer.com SERIES GL-QR STANDARD COVERAGE, QUICK RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 GENERAL DESCRIPTION Globe Series GL-QR sprinklers are Listed Quick Response sprinklers which utilize a 3mm frangible glass bulb as the thermosensitive operating element. These sprinklers are available in upright, pendent, and recessed pendent orien- tations. They are Listed and Approved as Standard Cover- age sprinklers and are to be installed in accordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13; FM 2-0). These sprin- klers are available in various K-factors, temperatures and finishes as shown. Recessed escutcheons with either 1/2" or 3/4" vertical adjustment are available (See Approvals Ta- bles for appropriate sprinkler/escutcheon combinations and Listings). Some pendent models are additionally available with a special 'Seismic" escutcheon to meet the IBC-ASCE/ SEI 7 requirements for use in seismic design categories C, D & E. OPERATION Upon exposure to heat such as from a fire, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid ex- pansion causes breakage of the glass bulb, resulting in re- lease of the water seat assembly, and discharge of water from the sprinkler. TECHNICAL DATA SIN Upright: GL2815, GL4215, GL5615, GL8115, GL8118 Pendent, Recessed Pendent: GL2801, GL4201, GL5601, GL8101, GL8106 Approvals cULus• FM • LPCB CE See Approval Tables Maximum Working Pressure 175 psi (l2bar) Factory tested to 500 psi (34 bar) Minimum Operating Pressure 7 psi (48 kPa) Temperature Rating See Approval Tables Materials of Construction Frame - bronze • Deflector - brass Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy• Seal - teflon Bulb - glass with alcohol based solution, 3mm Escutcheon Assembly - carbon steel I RECESSED PENDENT UPRIGHT PENDENT RECESSED PENDENT SEISMIC IBC/ASCE/SEI CODES FINISHES AND ACCESSORIES Finishes Factory Bronze • Chrome • White Polyester Black Polyester - special order Escutcheons Brass Chrome White Polyester. Black Polyester Wrenches Standard• Recess• 1/2" NPT 3/4" NPT NOTE: Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be expected when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmo- spheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, humidity, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTE: Users should refer to Globe's web site (www.globesprinkler.com) to ensure that the most recent technical literature is being utilized. SEP 2019 GFS-100 PAGE 1 OF 6 INSTALLATION NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak- age. It is recommended not to exceed 14 ft-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads; 20 ft.-lb. (26.8 Nm) to 3/4 inch NPT threads. Stepi. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note: Do not grasp the sprinkler by the deflector. Step3. Wrench-tighten the sprinkler using only the appropriate wrench. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to frame arms. FIGURE 1: STANDARD SPRINKLER WRENCH 1/ NPT P/N 325390 3/4 NPT PIN 312366 FIGURE 2: RECESSED SPRINKLER WRENCH V NPT P/N 325391 %" NPT PIN 325401 CARE AND MAINTENANCE Prior to installation, it is important to read and follow the "Sprinkler Caution" sheet (GFS-840) included within each box of sprinklers. This sheet is available on Globe's web site (www.globesprinkler.com). Store sprinklers in a cool, dry place. Exposure to extreme heat will damage the thermal sensing element, possibly re- sulting in premature activation. Avoid direct sunlight. Replace any sprinkler that shows any corrosion, damage, or loss of liquid from the glass bulb. Do not attempt to paint or alter the sprinkler's coating in any manner after leaving the manufacturing plant. Do not attach wiring, ropes, decorations or fixtures to a sprinkler. Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner's responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). SEP 2019 GFS-100 PAGE 2 OF 6 TABLE A: UPRIGHT SPRINKLER APPROVALS SIN GL2815 GL4215 11 GL5615t1 GL8115* GL8118t1 ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2" (15mm) 1/2" (15mm) 1/2" (15mm) 1/2" (15mm) 3/4" (20mm) HAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) FM Approved NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c105 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) CE NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. DEFLECTOR FRAME COMPRESSION SCREW BULB _jjjj 2-1/4 (57.1 mm) ____• BULB SEAT WRENCH FLAT IG OBE lIZ' NPT 7/16" (11.1 mm) NOMINAL MAKE-IN FIGURE 3: SERIES GL-QR UPRIGHT SPRINKLERS GL2815, GL4215, GL5615, GL8115 COMPRESSION BULB BULB SEAT— WRENCH 2-7/16° H (62 mm) 3/4" NPT SEP 2019 1/2' (12.7 mm) NOMINAL MAKE-IN FIGURE 4: SERIES GL-QR UPRIGHT SPRINKLERS GL8118 GFS-1 00 PAGE 3 OF 6 TABLE B: PENDENT SPRINKLER APPROVALS SIN GL2801 GL4201 (1) GL5601 " GL8I0I * GL8106 (1) ORIENTATION PENDENT PENDENT PENDENT PENDENT PENDENT K-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2' (15mm) 1/2" (15mm) 1/2" (15mm) 1/2" (15mm) 3/4° (20mm) HAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) FM Approved NA NA 175-F (79-C) NA 175-F (79-C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c/05 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) CE NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) I I 286°F (141°C) * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. SEP 2019 7/16" (11.1 mm) NOMINAL MAKE-IN 1/2" NPT WRENCH FLAT I BULB 4 t BULB COMPRESSION SCREW FRAME DEFLECTOR FIGURE 5: SERIES GL-QR PENDENT SPRINKLERS GL2801, GL4201, 0L5601, GL8I0I 1/2" (12.7 mm) NOMINAL MAKE-IN 3/4" NPT WRENCH FLAT 2-71W BULB SEAT BULB (62 mm) COMPRESSION SCREW FRAME DEFLECTOR FIGURE 6: SERIES GL-QR PENDENT SPRINKLERS GL8106 GFS-1 00 PAGE 4 OF 6 TABLE C: RECESSED PENDENT SPRINKLER APPROVALS SIN GL2801 (2) GL4201 (1)(2) GL5601 (1) (1) GL8IOI * (1)(2) GL8106 (1)(2)(3) ORIENTATION RECESSED PEND. RECESSED PEND. RECESSED PEND. RECESSED PEND. RECESSED PEND. K-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2" 1/2" 1/2" 1/2" 3/4" HAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) FM Approved 135:F (57 :C) 135:F (57:C) Note: %" Adjustable Recessed NA NA NA Escutcheon only 200°F (93°C) 200°F (93°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c105 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) "E NA NA 155°F (68°C) NA 155°F (68°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) * FOR RETROFIT USE ONLY cULus LISTED CORROSION RESISTANT SPRINKLER WITH POLYESTER COATING cULus I LPCB ICE APPROVED WITH 1/2" ADJUSTABLE AND 3/4" ADJUSTABLE RECESSED ESCUTCHEON FM APPROVED FOR BRASS FINISH ONLY -2 15/16' DIA.- 2' DIA. MIN. HOLE IN CEILING - REDUCER 6 1/8" MIN. MAX.- 1/2' AD]. 7/8' MAX. -3/4' CEILING CUP 1MIN RETAINER 13/4" MAX. - FIGURE 7: RECESSED ESCUTCHEON TABLED: STANDARD ESCUTCHEONS 314" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2°NPT 3/4" NPT Chrome 325422 325423 Brass 325424 325420 White Polyester 325426-W 325427-W Black Polyester 325426-B 325427-B Stainless Steel 326140 NA 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2" NPT 3/4" NPT Chrome 332071 326040 Brass 332072 326041 White Polyester 332073-W 326042-W Black Polyester 332073-B 326042-8 3 7/8' (98mm)- (101mm) DIA. MI HOLE IN CEILING REDUCER 1/8' (3mm) MIN. 5/8' (16mm) MAX. - 1/2' (12mm) AD). 7/8' (22mm) MAX. - 3/4' (19mm) AD). I. (25mm) MIS. 11/2" (38mm) MAX. - 1/2' AD]. 13/4' (44mm) MAX. - 3/4' AD). FIGURE 8: SEISMIC RECESSED ESCUTCHEON Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E. TABLE E: SEISMIC ESCUTCHEONS 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2" NPT 3/4" NPT Chrome 326170 326177 White 326172-W 326178-W 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2" NPT 3/4" NPT Chrome 326201 326208 White 326203-W 326210-W SEP 2019 GFS-100 PAGE 5 OF 6 TABLE F: PART NUMBER SELECTION PART NUMBER SIN + TEMPERATURE + FINISH xxxx xxx xx I liL SIN I i I TEMPERATURE GL2815 1 2815 GL4215 4215 GL5615 5615 0L8115 8115 GL8118 8118 GL2801 2801 GL4201 4201 GL5601 5601 GL8101 8101 GL8106 1 8106 -I- 135 135°F(57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F(141°C) FINISH 01 BRONZE 02 CHROME 03 WHITE POLYESTER 04 BLACK POLYESTER Note: All combinations may not be available. Refer to Listing/Approval Tables for available listed combinations. ORDERING INFORMATION SPECIFY: SPRINKLER Quantity SIN • Orientation Orifice• NPT • Temperature Rating Finish Part Number (See TABLE F) ESCUTCHEON Quantity Finish • Part Number (See TABLE D & TABLE E) WRENCH Quantity• Part Number 1/2" NPT Standard ....................325390 3/4" NPT Standard ....................312366 1/2° NPT Recess .....................325391 3/4" NPT Recess .....................325401 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 989-846-4583 • www.globesprinkler.com Technical Support. 989414-2600 • techservice®globesprinkler.com S SEP 2019 GFS-100 PAGE 6 OF 6 RC,,b'h Mt/ri o Cl Record of Completion ry Name of Protected Property: Acushnet 2nd floor TI Project (partial modification of existing FA system) Address: 2819 Loker Ave Carlsbad, CA 92010 Rep. of Protected Prop. (Name/Phone): Paul Alaksin / 760-603-5174 Authority Having Jurisdiction: City of Carlsbad Fire prevention Address/Phone Number: 1635 Faraday Ave Carlsbad CA 92008 / 760-602-4660 1. Type(s) of System or Service NFPA72, Chapter 3 Local If alarm Is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 3 Emergency Voice/Alarm Service Quantity of voice/alarm channels: _Single: _Multiple: Quantity of speakers Installed: _Quantity of speaker zones: - Quantity of telephones or telephone jacks included in system: - - NFPA 72, Chapter 4 Auxiliary Indicate type of connection: Local energy: _Shunt _Parallel telephone: - Location and telephone number for receipt of signals: NFPA 72, Chapter 4 Remote Station Alarm: Supervisory: NFPA 72, Chapter 4 Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: Indicate how alarm is retransmitted: X NFPA 72, Chapter 4-Central Station The Prime Contractor Nova Security Central Station Location: Night Security Means of transmission of signals from the protected premises to the central station: _McCulloh - Multiplex _One-Way Radio X Digital Alarm Communicator _Two-Way Radio Others Means of transmission of alarms to the public fire service communications center Dual Phone lines System Location: MPOE room Page 2 of 4 Organization Name/Phone Representative Name/Phone Installer Nova Security Andy Jordan 619-448-3007 Supplier Service Organization Nova Security Andy Jordan 619-448-3007 Location of Record (As-Built) Drawings: Provided to general contractor/ owenr rovided to Qeneral contractor! owner Location of Owners Manuals: Owner Location of Test Reports: Tested by other company A contract, dated , for test and inspection in accordance with NFPA Standard(s) No(s). dated , is in effect 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by Andy Jordan on 1.20.20 includes the devices shown below, and has been in service since 2/11/2010 XNFPA 72, Chapters (JI3(J)cle all that apply) XNFPA 70, National Electric Code, Article 760 XManufacturer's Instructions Other (specify): Signed: Organization: Date: 1/24/2020 Record of System Operation All operation features and functions of this system were tested by Andy Jordan on1/20/2020 , and found to be operation properly in accordance with the requirements of: X NFPA 72, Chapters 10I3C 1J(cie all that apply) X NFPA 70, National Electric Code, Article 760 X Manufactupiffs Instructions Signed: Organization: NovfSecurity Date: 1/24/2020 4. Alarm-Initiating Devices and Circuits (use blanks to indicate quantity of devices) existing devices not altard by TI MANUAL I Manual Stations I Noncoded, Activating _____Transmitters Coded (b)Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: Partial:____ (a)EXSmoke Detectors Ion Ph _____ oto Duct Detectors Ion Photo Heat Detectors FT RR FT/RR - RC EX Sprinkler Water flow Switches: Transmitters Noncoded, Activating Coded (e)_________Other (list): Page 3 of 4 5. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity, of devices) GUARD'S TOUR (a) Coded Stations (b)______ Noncoded Stations, Activating Transmitters (c) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations NOTE: Combination devices recorded under 4(b) and 5(a). SPRINKLER SYSTEM Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches, Activating Transmitters Building Temperature Points Site Water Temperature Points Site Water Supply Level Points Electric Fire Pump: Fire Pump Power ______ Fire Pump Running Phase Reversal Engine-Driven Fire Pump: Selector in Auto Position ______ Engine or Control Panel Trouble ______Fire Pump Running Engine-Driven Generator Selector in Auto Position (I) Control Panel Trouble (m) Transfer Switches (n)______ Engine Running Other Supervisory Function(s) (specify 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: $ new devices added Types and quantities of alarm indicating appliances Installed: (a)_______Bells Inch (b) Speakers (c)______ Horns Chimes Other 5 Visual Signals Type: Strobe 3 with audible 2 w/o audible 2 Local Annunciator Signaling Line Circuits Quantity and Style (see NFPA 72, Table 3-6) of signaling line circuits connected to system: Quantity: 1 Style: 4 System Power Supplies Primary (Main): Nominal Voltage: I20VAC Current Rating: 26Amp Overcurrent Protection: Type: Breaker Current Rating: 20Amp Location: MPOE Room Secondary (Standby): FAPS X Storage Battery: Amp-Hour Rating 7 Amps X Calculated capacity to drive system, In hours: - X 24 60 ______ Engine-driven generator dedicated to fire alarm system: Page 4 of 4 Location of fuel storage: (C) Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: Emergency System described in NFPA 70, Article 700 Legally Requited Standby System described in NFPA 70, Article 701 ______Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software System Is in proceess of being upgraded Operating System Software Revision Level(s): Application Software Revision Level(s): Revision Complete by: (name) (firm) 10. Comments: System Is slated to upgraded In 2020 (signed) for Central Station or Alarm Service Company (title) Project Manager (date) 1/24/2020 Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA Standard(s): Waterfiows & Sprinkler Tamper Valves Quarterly, All others annually System deviations from the referenced NFPA standard(s) are: (signed) for Central Station or Alarm Service Company (title) Project Manager (date) 1/24/2020 Upon complejouf theftystem(s) satisfactory test(s) witnessed (if required by the Authority Having Jurisdiction): Repreen(tive of the Authority Having Jurisdiction (title) (date) See aproved plans for AHJ mark Reprinted with permission from NFPA 72, National Fire Alarm Code, Copyright 01999, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject which is represented only by the standard in its entirety. Distributed by: AFAA - P.O. Box 951807 Lake Mary, FL 32795-1807 Phone —(407) 322-6288 Fax—(407) 322-7488 Web—www.afaa.org