Loading...
HomeMy WebLinkAbout2819 LOKER AVE E; ; FPC2020-0058; Permit24:1II:11I61:I CL7city of Carlsbad Print Date: 12/08/2020 Job Address: 2819 LOKER AVE E, CARLSBAD, CA 92010-6626 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090831600 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: ACUSH NET -FIRE ALARM PANEL REPLACEMENT Permit No: FPC2020-0058 Status: Closed - Finaled Applied: 04/02/2020 Issued: 04/27/2020 Finaled Close Out: 06/23/2020 Inspector: Final Inspection: Applicant: FPContractor: NOVA SECURITY NOVA SECURITY CORY HILL 8779 COTTONWOOD AVE, # STE. 103 8779 COTTONWOOD AVE, # STE 103 SANTEE, CA 92071457 SANTEE, CA 92071-4457 (619) 448-3007 (619) 448-3007 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov - ACUSHNET 2819 Loker ave Carlsbad, CA. 92010 Fire Alarm Submittal 03/26/2020 Submitted By; NVA SECURITY 8779 COTTONWOOD AVE. Santee, CA. 92071 619-448-2021 Cont. Lic. C-10 # 802053 ACUSHNET Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# Fire Alarm Panel VS-4R KIDDE 7165-1657:244 Renote Annunciator RLCD-C KIDDE 7120-1657:254 Smoke Detector KI-PD KIDDE 7272-1657:331 Heat Detector KI-HRD KIDDE 7270-1657:333 Input Module GSA-CT1 KIDDE 7300-1483:115 Relay Module GSA-CR KIDDE 7300-1483:115 Strobe (clg mnt) SCWL SYSTEM SENSOR 7125-1653:504 Horn/Strobe (clg mnt) PC2WL SYSTEM SENSOR 7125-1653:503 Strobe (wall mnt) SWL SYSTEM SENSOR 7125-1653:504 Horn/Strobe (wall mnt) P2WL SYSTEM SENSOR 7125-1653:503 Cell Communicator TG-75 TELGUARD 7300-1402:500 o gd Technologies Technology that saves lives Intelligent Fire Alarm Systems VS1,VS4 Overview Kidde brand intelligent life safety systems offer the power of high- end intelligent processing in configurations that deliver uncompli- cated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily-configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The VS1 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with-the use of a module. The VS4 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. VS4 panels include four NACs that may be wired for either Class A or Class B operation. The RZl16-2 module adds even more capacity to VS installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them ideal retrofit solu- tions that can accommodate new intelligent detectors, as well as existing conventional devices. VS Series supports a wide range of high-end features, including: Intelligent modules, detectors, and bases GSA-REL Releasing Modules A-Series remote annunciators Fully integrated CO detection using KI Series of detectors including distinct audible signaling Page 1 of 8 L[E Catg> Small Building Fire Alarm Solutions FDNY COA 6229 * 7165-1657: 0244 53000 Features Auto-programming reduces installation time Supports 10-year carbon monoxide detectors Form C contacts for alarm and trouble, Form A for supervisory Electroni6addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Supports next genertion Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Supports GSA-REL releasing module for fire suppression Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour Alarm ON command manually activates alarm condition D A I A S H E, , K85005-0135 Not to jo osod lo, insta,l.t;on p. o.' . . Issue 1.4 Application Kidde VS Series life safety systems are powerful intelligent solutions for small to mid-sized buildings. Advanced intelligent technology delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Meanwhile, innovative pro- gramming allows the designer to customize the system to pre- cisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Address- able Technology boosts the reliability of Kidde fire alarm systems. When combined with VS Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All Kidde systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the VS Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. VS control panels also supports graphic annunciation with optional graphic annunciator interface modules. Each interface provides common control and 32 LEDs. Signals with a difference VS Series NACs are configurable to fully support the advanced signaling technology of Kidde Genesis and Enhanced Integrity no- tification appliances. These devices offer precision synchronization Programming and remote diagnostics Kidde VS Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, VS Series systems interface to a PC running com- patible VS-CU software. This option offers full system configura- tion in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of VS Series contrcl panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to down- load to the panel from the VS-CU, or upload and view system reports using the VS-CU. Available system reports include: Correlation groups, Device de- tails, Device maintenance, History, Internal status, System configu- ration, System status, Walk test, Dialer, and CO runtime. Page 2 of 8 of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits Kidde VS Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to VS technology without the expense or disruption of rewiring the entire building. VS control panels also support the ingenious RZI1 6-2 zone module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intel- ligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Scalable IP and Cellular Communications Several popular third-party (P/Cellular communicators have been tested with the VS control panels and are compatibility listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/ Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the VS control panel compat- ibility documentation part number 3102354-EN for a full list of compatible communicators. A complete line of accessories VS Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions 4E (2) (3) (4) r rjf T I II II 1 0 I 0 4 44 O9 (1) Surface Mounting Holes (3) Backbox with Door Attached (2) Semi-flush mounting Holes 141 Backbox with door and tdrr kit attached. Panel dimensions, in (cm) Mode(101 i 021 03 b4'1 05 I o6r6D8 r D9 I l71.,j 19.81 1 (22j (55.8) i (40.0) (26.0) j (6,8) vsi 1 21.5 j 3.85 7.,,,5 15.5 14.25 J 10.25 49 23.6 2.7 Add 1-1/2 in. (3.81 cm) to Dl and 05 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. K85005-0135 Not • b' '.'u ' , t,ton 'u ","s,. , Issue 1.4 System Layout VS4 Any combination of two single- or dual device loop modules ;1 I '-c Standard Loop: 250 points (one expansion slot) V-SLC2-2 Expander, Loop 1 of 2:250 points J Up to 125 sensors and 125 modules per loop (one expansion slot) I At V-SLC2-1 Expander Loop: 250 points (one expansion slot) V-SLC2-2 Expander, Loop 2 of 2: 250 points Up to 20,000 feet of wiring per loop LF ----------- * .......... i ......... -------- - Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZ116-2 module Panel Layout - 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each VS4 panel has room for up to two device loop controller modules in any combination of single or dual 250-device loops. VS4 comes with one loop that supports up to 125 detectors and 125 modules. VS 1 LV LV,VVV ICCL VI VVIuIII. o_ -- Up to eight i& itO annunciators Ethernet (SA-ETH) DACT/Dialer (SA-DACT) Cr RS-232 (SA-232) - Relays: Two Form C, one Form A - Each VS1 panel ships with one device loop controller that sup- ports 64 devices of any type. This panels device capacity cannot be expanded. 3 2 5 6 8 I- Ix Page 3 of 8 DATA S HEET K85005-0135 Not to h ,sa lo tai jation ¶.'l ?L Issue 1.4 Trouble Supervisory Alarm Smoke/Aux Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. Alarm, trouble, and supervisory relay (TB3) The trouble relay is normally-open, held closed, and opens on any trouble event or when the panel is de-energized. The supervisory relay is normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Circuit Device loops line voltage Circuit current Circuit impedance Isolators VS4 l VS1 One Class B or A i One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Maximum 20 V peak-to-peak 660 total, U.b pt-, max 64 maximum 0.5Amax. Wiring & Configuration Device loop The system provides one device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Signal I Supported on a system-wide basis (all device loops) Synchronization 1 when using an addressable notification appliance I circuit (NAC) module and Genesis or Enhanced lntearitv notification acoliances. 0000 B wiring Class A wiring Loop Loop cord device devim LOOP Card Data Una llotification appliance circuits (TB2) VS4 control panels come equipped with four notification appliance circuits. VS1 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications VS4 VS] 67-77Type t 4 Class Bor2 Class A 2 Class Bor2Class A with SA-CLA module 24VFWR 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. 26 0 total, 0.35 pF max 15 KO, ½ W Supported system-wide Class A wiring DLR DLR Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Page 4of8 DATA K85005-0135 nr to ',' -ood ' t,,Jto,i c.Ør5'-. Issue 1.4 Auxiliary & smoke power outputs (1B3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. Circuit specifications Circuit voltage 21.9 to 28.3 V range _______ Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) ______ ______ Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. I TB3 NC 7NC NO Alarm i Trouble l Supervisory Type Form C Form A -- voltage i 24VDCatiArestivej 24 pCat1Aresis5ve Relay circuits can only be connected to power-limited sources. Class B wiring Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications _______________ Device loops Class B (Style 's') or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet Class B Class Channel 1 channel 2 channel 1 channel 2 +—+— inundator Annunciator clii (+) IN cHi f-f IN cHi (-) IN CH2 (+) IN I I-I. CH2 (+) IN CH2 (-) IN I cH2 f-f IN Option Cards Kidde VS Series panels are supported by a complete line of mod- ules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet pro- vides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The V-SLC2-1 is a single loop controller card that can be used with the VS1 as a replacement for the standard 64-point loop, or with the VS4 as a 250-point expansion module. The V-SLC2-2 is a 500-point dual loop controller card for the VS4 that provides two IDC circuits, each with 125 detector addresses and 125 module addresses. Specifications V-SLC2-1 iV-SLC2-2 resses if VS4: one loop, 250 1 VS4: two loops, 500 device addresses 1 device addresses VS1:64addressesL Class B or Class A 24 VDC Operating Current j Standby: 55 mA I Standby: 45 mA (fully loaded loop)Alarm: 8OmA Alarm: 7O mA Note: These ratings do not include the use of two-wire smoke modules. Communication Une iax. 20.6 V peak-to-peak Terminal Rating 12 to 18 AWG (0.75 to 2.5 Circuit Current 0.5 A max. Max total loop 66 0 resistance Max total loop 0.5 pF Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F SA-ETH Ethernet Interface Card The SA-ETH card provides a standard 10/100 Base T Ethernet network connection for connect- ing to an intranet, a local network, or the Internet. The card can be used to download configuration programming from the VS-Cu to the panel. The Ethernet card is installed on the plastic assembly and con- nects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) RZ116-2 Remote Zone Interface Module The RZ116-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. The RZI1 6-2 requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI1 6-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications - - Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm current: 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1,NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 rn/V circuit Standby current for 3.9 k EOL (Canada) 5.7 rn/V circuit Alarm current at nominal voltage 31.1 mA' circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kfl (Canada) Alarm current 31.1 rn/V channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kfl Supervised output circuits EOL resisfor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kfl Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), VS4, APS Page 5of8 DATA HEET K85005-0135 Not to be u,oci For intlbt3or- ':upo' Issue 1.4 SA-DACT wiring ,e jack The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector Ji. (4) LED 1 LED 2 SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the VS-CU. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications - Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (031 /38) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBII 0P220 __ Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch 06600 _____ Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface The SA-232 card provides an RS-232 in- terface with VS panels. It can be used for connecting a printer to the control panel to print system events. The card also can be used for connecting a computer to download a configuration program from the VS-CU to the control panel. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard_EIA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (VS1 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with VS1 control panels only. VS4 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating c.urrent 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Dl 6L-V5 LED Display Expander (VS4 only) The D1 6L-VS LED Display Expanders provide LED annuncia- tion for up to 16 zones. It provides two LEDs for each zone. Two D1 6L-VS LED display expanders can be installed in each VS4 panel. LED Expander 1 LED Expander 2 Piarm/non-alarm and trouble zone LEDs Page 6 of 8 K85005-0135 "0 1 ro b. i i-e':l fo tOl,t,on 1 i , issue 1.4 Specifications VS1 VS4 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (1 25 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style 'i'), Class A (Style Z) optional 4 Class B (Style 'y) or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base current standby, _panel 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) circuit Aux power 2: 500 mA, 24 VDC Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the VS1 and VS4 Series Compatibility List (P/N 3102354-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet. If larger batteries are required, use a battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kO Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) ________ Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Eniironmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7 of a DATA SHFFT K85005-0135 Not to no used ',oi irstdiloL'oyl pu.p,,t issue 1.4 Technology that saves lives Contact us... Email: kidde.are@fs.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2019 Waiter Kidde Portable Equipment. AJI rights reserved. Ordering Information Part Description VS4 Fire Ala rmSystems ____-.. fuwith one 250-pnjoop installed. 11 Ov, gray d99r._________ VS4-6-2 Four loop system with one 250-point loop installed. _23Ov, gray door VS4-G2-PG Four loop system with one 250-ppj99p lostalled. 23w, gray d09r, Portuguese. VS4-G-2-SP loop sj(stem with 0ne2 2Ov.grayoor,Spaoish._____ VS4-GC Fo system, one 250-polotloopinstaUed.1iov,gpydoo.LE.sthps, Canada. VS4-GD Four ioop system, one 250-point ioopinstated. 1 .0v,gpydoo VS.4-GFFour loop system, one 250-point loop. .J,y,dpoJDstrips, French Canada. VS4-G-PGFour loop system wth 0ne250-pointioopinstailed.1 9yray.o.or, Portuguese. VS4-GSP .F6'ur loop system with one 250,- oop instated. 11 Ov, gray door, Spanish. VS4-R_Four loop system with one 250- loo installed. 11 Ov, red door. Y±:?±.i99P system with one 250-point loop instated. 230v VS4-RD Four loop system,_one2point loopinstalled.1 10v, red door, with dialer. - ........ SA-TR1M2 VS4 Flush mount trim, black. VS1 Fire Systems _ VS1-G One loop pystem —with--o 64 one -point loop instated. 110v,gpy9or VStG2 -- One loop sstem with one 64-ppint loop installed. 3Qyay(pp.__. .... QaJcop...5y[hpo.nt loop nstalled..........door, Portu.guese. One ioopsystem withone 6pp!ntiopjsta Ile d.230 gray door, paoish. VS1-GD One loop system, one 64-point loop installed. 11 Ov, gray door, with dater. VS1 -GL One loop system, one 64-point loop instated. 110y, gray door, EngjishCanada - VS1 -GL-F - One loop system, one oin e -tloop installd. I 9 pydoor,FrenchCanada. VS1 -G-PG - -- Oneioop system with VS1 -G-SP Oneloop system with onp9t loop_installedjQgray door, Spanish. VS1 -R One loon system with one 64-noint loon installed. llOv. red door. VS1 -RD One loop system, 4-fll°.nt loop installed.110y, red door, with Jdialer SA-TRIM1 VS1 Flush mount trim, black pon Cards - -.--.,,- Expansion module,one250-device ioqp. For VS.4on_ ._____ V-SLC2-2 Expansion module, two 250-devllceioop&OO devices total. ForVS4only. . Remote Zone Interface Module. 16 Class BlDCs,2 Class B Output.Bracketinduded. SA-DACT Dual Line .Dialer/Modem,..supp Contact ID, mounts in cabinet on elate. - . - R232S Port edtion(ppters&computers, mounts in cabinet. SA-ETH Ethernet Port. Slave, mounts in cabinet on base olate. on NAUS. mounts in caDinet on - ................mainboard.vS1 systems jy.* D16L-VS LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in aoright of LCD LYdisplay. FoS4 2oIy....... ........ ................. D8RY-VS Canada only: LED Annunciator module, two LEJs per zone, 16 zones (4 alarm only, * 8supe only,4 alarm or suo ). Mounts in cabinet.For VS4ody. Accessories CTM City Tie Module. 2-gang. Connection to a local energy firealarmbox, MFC-A Multifunction Fire Cabinet, 8' x 14" x 3.5" -red. BC-1 Battery Cabinet. 14.0' x 18.25" x 7.25". Holds two 12V24A batteries. BC-1R Battery Cabinet - Red. 14.0" x 18.25" x7.25". Holds two 12V24A batteries. GSA-REL Releasing Module BC-1 EQ Seismic hardening Kit for VS Series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Page 8of8 )At. Ht K85005-0135 'c,t r, n icecr or r .tjii,t,or, .r' poss. Issue 1.4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterfiow and sprinkler supervisory service. Models "EST' i01000G, iO1000G-2, iO10000D, i01000R, iO1000R-2, i01000RD, i064G, 064-GD, i064-R, i064-RD, i064G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VS1-G, VSI-GD, VS1-R, VS1-RD, VS1-G-2, VS1-R-2; VS2-G, VS2-GD, V52-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, vs4-GDvs4-Rvs4_r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FX1000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module D16L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XAL127; SLC Loop Driver io-SDC1, V-SLC2-1, FX-SLC1 Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pT1..S: System Printer *pll..p: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. "102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. *102416 dc r&p This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1*V1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division KlUDE Caiog 11> Annunciation 11* United Technologies Technology that saves lives R-Series Remote Annunciators RLCD, RLCD-C RLED, RLED-C, RLED24, GCI ri FONY 7120-1657: GOA 6020 0254 S3424 [j Overview Kidde A-Series Annunciators are high-performance remote an- nunciators that provide status indication and common controls for compatible fire alarm control panels. This family of annunciators offers LCD or LED annunciation. Models are available with and without common controls. There are three A-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- ciator. The expander includes 24 pairs of LEDs that extend the capabilities of any of the annunciators. All annunciator models include status LEDs and an internal buzzer. Two models have an LCD text display, and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, four by twenty character per line, super-twist liquid crystal display. A-Series annunciators and expanders are mounted on a standard 4-inch square electrical box, using the included mounting ring. They can also be surface mounted in locking steel enclosures. Three different enclosures are available. A keyswitch and graphic annunciator interface is available for A-Series annunciator applications. The keyswitch enables or dis- ables common controls. The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic pane! display. Features LCD models feature large 4 x 20 character backlit LCD display LED models provide 16 pairs of LEDs for zone annunciation Available expander extends capability with 24 pairs of LEDs Up to two expanders may be wired to each annunciator Status LEDs and internal buzzer standard on all models Common controls available for LED and LCD display models Available keyswitch for disabling common controls Standard 4-inch square electrical box mounting Class B or Class A R5485 wiring standard One-, two-, and three-position enclosures available Graphic Annunciator interface, includes common control, indi- cators and 32 LEDS No programing required, set the address and unit receives all information from panel Page 1 o 4 DATA SHEET K85005-01 28 Not to be used for nstaiation purposes. Issue 1 Application A-Series annunciators communicate with the FACP on the RS-485 data riser. This can be configured for Class A or Class B commu- nication. Annunciators do not provide ground fault isolation. These annunciators are stand-alone units that can be powered by the FACP or by an approved power supply. Annunciator Wiring Annunciator, Class A FACP Annunciator Annunciator R5485 ciii (,)IN 0 ciii IN cu-n ø CHI )-)IN Ø CHI (-lhN ciii - ciii (n) OUT (3Ciii (0) OUT cr12 CHI (-)OUT (2) CHI (-I OUT cr12- ØCH2 (+)lN 0 CH2 )o)lN ØCH2 (-)IN Ø CH2 )-)IN LISTED 24 voc C112 () OUT (2) CH2 (0) OUT SUPPLY CH2 (-I OUT 0CH2 (-(OUT 24vDc+ (3 Ø24v(-n)IN Ø24V)+)IN 24v0c- (3 024v(-)IN 24V IN 24V (°) OUT 0 24V (n) OUT 24v (-) OUT (324V (-) OUT GROUND GROUND oI I !10 RLCD-C RUED-C RLCD RLED24 Features by model RLCD RLCD-C FILED-C RLED24 Reset I - Ack/Silence I I I - FireAarm I I I - Supervisory I I I - Ground Fault I I I - Trouble Controls Enabled I I '/ - AckiSilence I I I - Reset I I - Signal Silence / / - Drill Lamp Test I I I - LCD Display I I - - Zone Active LEDs - - 16 * 24 ** Zone Trouble LEDs - - 16 24 *zones 13-16 maybe selected as Supervisory on FX-64 and VS 1 zones 13-16 and 29-32 may be selected as Supervisory on FX- 1000 and VS4 Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that connects the tire alarm control panel to the display panel of an LED-based graphic annunciator. The annunciator card supports 32 LEDs and 16 switches on the graphic panel display. It includes status LEDs and an internal buzzer. The graphic interface is supplied with snap track mounting. It is attached to a plastic mounting rail that requires two EIA panels. The annunciator communicates with the FACP on the RS-485 data riser. This can be configured for Class A or Class B commu- nication. The annunciator does not provide ground fault isolation. It is a stand-alone unit that can be powered by the FACP or by an approved power supply. Graphic Annunciator Interface Specifications Alarm current 146 mA at 24 Vdc (with 36 LEDs ON) Standby current 36 mA at 24 Vdc (with no LEDs ON) Maximum current 10 mA per LED Page 2 of 4 Annunciator, Class B FACP Annunciator nnunciator RS-485 ciii ('-) IN Ciii )-*) IN -n CHI I-) IN Ciii I-) IN Z - CHI (n) OUT ØCH1 -n) OUT ciii (-(OUT ciii I-) OUT cr12 (ni IN 0 CH2 (-ci IN cr12 (-I IN CH2 (-I IN LISTED 24 vDc cr12 1-c) OUT 0cH2 (c-I OUT SUPPLY CH2 (-I OUT 0 CH2 I-) OUT 24 voc 24V 101 IN 24V 101 IN 24 VDC - 24V (-I IN 24V (-I IN 24v (°) OUT 0 24V (-c) OUT 24V (-I OUT Ø24V (-(OUT GROUND GROUND Expander I H .1 1 Remote Keyswitch Annunciator LSRA.RK KEYSWITCH KEYSwITcH (01 (3 Keyswitch Specifications Maximum 5Vdc voltage Maximum 200 mA current Mounting 2-1/2 in (64 mm) deep 1-gang box Termination Screw terminals Maximum 12 AWG wire size (2.5 mm sq) Contact Normally open configuration DATA SHEET K85005-0128 Not to be used for installation purposes. Issue 1 - H - H - H - l - H - H - - 991 RA-ENc3 Annunciator Connections Annunciator Expander cable terminals DIP switch settings Switch Description and values Si to S5 The annunciator network address (in binary). Network The factory setting is for address 2. address Examples: 10000 = 1 01000 = 2 11000 = 3 00100 = 4 56 Network OFF = 9600 baud (factory default setting) baud rate ON = 38,400 baud S7 to S8 Not used Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white, painted finish. Each enclosure includes a security lock and two keys. The two- and three-position enclosures have wiring channels for cor- rect routing of interconnections. The enclosures attach to a standard electrical box, and provide a mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. ?' \ RA-ENC1 RA-ENc2 Page 3 of 4 Annunciator Mounting MOUNTING RING EXPANDER ELECTRICAL BOX 6.0 in 15.2 cm H 0.9 in 2.3 Cr 9.5 in ll I Ii 24.1 cm II 2.0 in I I 9.81n 5.1 cm I 24.9 cm Dimensions (H x W x D) RA-ENC1 6.3 x 9-".-8'x 2.0 in (16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x-,-9",-8,-"x 2.0 in (30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in (45.0 x 24.9 x 5.1 cm) Note: Allow approximately 2 inches (50 cm) clearance on both sides of the enclosure, to permit inserting and removing the key, and opening the door through 90 degrees. DATA SHEET K85005-0128 Not to be used for installation purposes. Issue 1 Mounting slot DIP switch RS-485 riser terminals Power terminals Communication LEDs Expander Mounting slot Expander cable terminals Remote keyswitch terminals Expander cable terminals Technology that saves lives Contact us... Email: kidde.flre@fs.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. Specifications RICO-C RLCD RLED-C RLED24 Operating voltage 24 VDC, continuous. Standby current 99 mA 98 mA 28 mA 6 mA Alarm current 115 mA 113 mA 62 mA 34 mA RS-485 communications Class A or Class B, 9600 baud Data wiring 18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot ______ minimum). Maximum wire run is 4,000 ft. (1,219 m) Remote key switch circuit 5 VDC at 1 mA, power-limited, unsupervised fault impedance Power wiring 18 to 14 AWG (1.0 to 2.5 sq. mm) Display area 4 lines of 20 characters each © 2018 Walter Kidde Portable Equipment. Dimensicns (H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm) PJI rights reserved. Mounting North American 4-inch square electrical box or listed enclosure Agency Listing UL, ULC Operating environment Temperature: 32 to 120°F (0 to 49°C) Humidity: 0 to 93% RH, noncondensing at 90°F (32°C) Ordering Information Part Description Remote Annunciators K-RLCD LCD text annunciator without common controls. English. K-RLCD-R LCD text annunciator without common controls. English. Red. K-RLCD LCD text annunciator without common controls. French. K-RLCD-C LCD text annunciator with common controls. English. K-RLCD-CR LCD text annunciator with common controls. English. Red. LCD-CF LCD text annunciator with common controls. French. K-RLED-C 16-pair LED zone annunciator with common controls. English. K-RLED-CR 16-pair LED zone annunciator 'with -control's-'."'E" nglish. Red K-RLED-CF 16-pair LED zone annunciator with common controls. French. Remote Expanders K-RLED24R 24-pair LED zone expander with expander cable and zone insert. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three -position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-MlR-SB Surface Mount Box - for single H Series annunciator. Graphic Annunciator Drivers GCl Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch -on plate for enabling common controls (Lock/Unlock). 27193-16 Electrical box, surface mount, white, single-gang, for RKEY Page 4 of 4 DATA SHEET K85005-0128 No to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-1657:0254 Page 1 of 1 CATEGORY: 7120-- ANNUNCIATORS LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models RLCD, E- RLCD, RLCDF, RLCD-C, E- RLCD-C, RLCD-CF "LCD" Annunciators; RLED-C, E- RLED-C, RLED-CF "LED" Annunciators; RA-ENC1, RA-ENC2, RA-ENC3 Cabinets; RLED24 Remote Expander, LED24X Remote Annunciator Expander, Rkey Remote Key Switch; GCI, *GCINB and GCIX *Drivers.Models RLCD, RLED, RLED24 may be followed by "R" which designates the color red. * GCl-24R, GCl-24Y, GCI-24G and GCI-24RY Remote LED Display Modules; *GCl..125/12R GCI-12S/12Y, GCl-125/12G, GCI-12S/12B, GCI-12S/12RY, GCI-125/12YY, GCl-12SI12GY and GCI-CC Remote LED Display/Switch Modules; GCI-FP *Filler Plate Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annunciators and accessories for use with separately listed compatible fire alarm control units. *Rev 06-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division KDDE C1oog lo, Intelligent Initiating Devices (rLEC T P0 N ADD RESSING# Technology that saves lives Intelligent Smoke I Detector _ KI-FD ,' y.- \ I I R1 S853 Overview Standard Features The KI-PD optical smoke detector brings advanced sensing Note: Some features described here may not be supported by technology to a practical design that increases efficiency, saves all control systems. Check your control panel's Installation and installation time, cuts costs, and extends life safety and property Operation Guide for details. protection capabilities. Continuous self-diagnostics ensure reli- Next generation optical smoke sensing technology ability over the long-haul, while environmental compensation helps reduce maintenance costs. Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration Like all KI Series detectors, the Kl-PD is an intelligent device that Uses Existing Wiring gathers analog information from its optical sensor, converting this Automatic Device Mapping data into digital signals. To make an alarm decision, the detector's on-board microprocessor measures and analyzes sensor read- Up To 250 Total Addresses Per Loop ings and compares this information to historical data. Digital filters Two Levels of Environmental Compensation remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Identification of Dirty or Defective Detectors Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status Led Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Page 1 of 4 DATA SHEET K85001 -0646 Not to bo used for installation purposes. Issue 1 ~~Red Technologies Application The KI-PD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its high- performance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Compatibility The KI-PD detector is compatible with Kidde VS and VM series panels. Installation KI Series detector bases mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon .. ?. boxes, and to 4 inch square elec- sIf.lOCbflE tab trical boxes 1-1/2 inches (38 mm) deep. They mount to European — BESA and 1-gang boxes with 60.3 ( ;' mm fixing centers. See mounting LED Indicator base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each KI Series detector constantly runs self-checks to provide important maintenance in- formation. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity mea- surements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are acces- sible from the 'room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The Kl-SB4, KI-RB4, and Kl-1B4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the GSA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The KI-ABST mounts to a 4 inch square box only. -- ' / • - -- ,-- -, - ..-- - .- Kl-ABST/T/LF Kl-SB KI-IB KI-RB GSA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED GSA-LED - The remote LED connects to the KI-SB or KI-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. GSA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - KI Series sounder bases are designed for use where localized or group alarm signaling is required. KI-ABST bases provide sounder capability to KI Series heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. KI-ABDT bases provide sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. KI-ABLT bases provide 520 Hz low frequency sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. The KI-ABLT is suitable for ap- plications requiring low frequency audible tones. Page 2of4 DATA SHEET K85001-0646 Not to be used for installation purposes. Issue 1 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. AB4GT AB4G, AB4G-LF sounder bases Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, Kl-SB, Kl-SB4 Kl -ABST, -ABDT, KI KI-ABLT: Output Mode Kl-ABLT: Jumper CUtS Default = Fire This is the basic mounting base Remote LED Volume Setting Cut/remove jumper for for Kidde Kl Series detectors. Max resistance Default = High Fire plus co The GSA-LED Remote LED is di'— per wire Cut/remove jumper for KI-ABST: must supported by this not exceed ohrns low d13 Tone Setting Base. 1J,j 10 M11 M- xis. am- our ox iworrr Default = Temporal Cut/removejumperfor 'Term Description I D AT I 1 Not Used I 0 Steady I 2 DATA IN/OIJT (+) KI-ABDT: I 3 Not Used I I 4 DATA IN(-) I Not Used I 4 Remote LED (-) I DATA IN I-) I 5 Remote LED () I I 6 Not Used I > 7 DATA OUT - DATA IN (+1 DATA OUT 24 Vdc in - - 24 Vdc a t From Signature Controller To Neat Device From power supply or base +) previous - + To neat base or EOL relay or Previous Device Data in - Data out Isolator Detector Base, KI-IB, KI-1B4 -, From Kl Device Controller ) to next KI Series device or previous device + This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED. OUT (.) Ulubu 10 Pr UVIUU LI II& UAIA IN 1+) next isolator down the From Signature Controller or Previous Device line with power - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. This detector does not sense fires in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector. Photoelectric detectors have a wide range of fire-sensing capabilities and are best suited for detecting slow, smolder- ing fires. In Canada, install according to CAN/ULC-5524 Standard for the Installation of Fire Alarm Systems, CSA C22.1 Canadian Electrical Code, and the local authority having jurisdiction. The isolator operates as follow - a short on the line causes all lators to open within 23 mse - at 10 msec intervals, beginning on one side of the Class A DAT circuit nearest the loop controller, the isolators OUT (+) To Next Device Term Description 1 Not Used 2 DATA lN/OLff (~) 3 DATA IN)-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used Relay Detector Base, Kl-RB, Kl-RB4 No-oily. Normally- This base includes a relay. Nor- mally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) © 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The Kl-RB DA can be operated as a control OUT (-) relay if programmed to do so at DATA IN (u) DATA OUT (+) To Next Device the control panel. The relay base From Signature Controller or Previous Device does the GSA-LED not support Term DescTptioT I 1 Norm ally Open Remote LED. CONTACT RATING 2 I DATA IN/OUT(+) 1O Amp @3OVDC 3 Common I I (Pilot Duty) 4 5 6 7 DATA IN Not Used Normally-Closed I DATA 01fF).) Page 3 of 4 DATA SHEET K85001-0646 Not to be Used for installation purposes. Issue I Dimensions 'Kidde V Technology that saves lives (1 - r (I Contact us... Email kiddefire@fs.utc.com / Web kidde corn/en g,neeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States V_ and other countnes. © 2018 Walter Kidde Portable Equipment. All rights reserved. . Specifications Operating voltage 15.20 to 19.95 VDC - V Normal operating current 51 pA Alarm current 68 pA Smoke Sensitivity Range UL/ULC:_0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft/mm (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatible detector testers Testif ire 1000, Testifire 2000 ___________ Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing Construction High Impact Engineering_Polymer, White Storage temperature -4 to 140°F (-20 to 60°C) Environmental compensation Automatic Agency Listi t'i'n' CAN/ULC-5529, UL 268, UL 268A ________ Ordering Information Catalog Ship Wt. Number Description lbs (kg) Kl-PD ntellgen Iit ector Optical Smoke Det 0.4 (0.16) Accessories ---------------- Kl-SB Detector Mounting Base - Standard Kl-SB4 4-inch Detector Mounting Base c/w Trim Skirt Kl-RB Detector Mounting Base w/Relay Kl-RB4 47inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09) KI-lB4 GSA-LED 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt Remote Alarm LED (not for EN54 applications) KI-ABST Audible (Sounder) Base for Fire Detectors 0.3(0.15) Kl-ABLT Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3(0.15) Kl-ABDT Audible (Sounder) Base for CO and Fire Detectors 0.3(0.15) GSA-TS4 Trim Skirt with 4-inch bases) _(supplied 0.1 (0.04) GSA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) GSA-DMP Detector Mountino Plate 3.0 (1.4) Page 4 of 4 DATA SHEET k85001 -0646 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:0331 Page 1 of 2 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-PD, *slGlPD *Kl..pD and *KIRPD Analog addressable photoelectric smoke detectors.*Model SIGI-PD is similar to Model SIGA-PD except for isolation circuitry. *Model Kl-PD is identical to Model SIGA-PD except for trade name. *Model KIR-PD is similar to Model SIGA-PD except for control panel compatibility. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-PD and SIGI-PD are under the Edwards brand. *Models Kl-PD and KIR-PD are under the Kidde brand. APPROVAL: Listed as analog addressable photoelectric smoke detectors. *Model Kl-PD is for use with listee's Models VS1, VS2 and VS4 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657:0309) fire alarm control units. *Models SIGA-PD and SlGl-PD are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); i064, i0500 and i01000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Model KIR-PD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control units. *Model SIGA-PD is for use with listee's bases: Models SIGA-SB, -5134, -RB, -RB4, -IB, -1B4 (CSFM No. 7300-1657:0120); SIGA-AB4G (CSFM No. 7300-1657:0222); SIGA-AB4GT (CSFM No. 7300-1657:0307) and SIGA-AB4G-LF (CSFM No. 7300-1657:0322). *Model SIGI-PD is for use with listee's bases; Models SIGI-AB4G (CSFM No. 7300-1657:0222); SlGl-AB4GT (CSFM No. 7300-1657:0307) and SIG!-AB4G-LF (CSFM No. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I Listing No. 1657:0331 I. Page 2 of 2 7300-1657:0322). *Models Kl-PD and KIR-PD are for use with listee's bases; Models Kl-ABST (CSFM No. 7300-1657:0222), KI-ABDT (CSFM No. 7300-1657:0307) and Kl-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-15-18 gt rs This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires 'June 30, 202O Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division KDDE ("~~talnq 0, Intelligent Initiating Devices 0 United Technologies Technology that saves lives Intelligent Heat Detectors KI-HRD, KI-HFD Overview The KI Series smoke detectors bring advanced sensing technol- ogy to a practical design that increases efficiency, saves installa- tion time, cuts costs, and extends property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while the latest thermister technology makes these detectors ideal wherever dependable heat detection is required. The KI-HRD is an intelligent fixed temperature/rate-of-rise fire detector. It monitors the temperature of the surrounding air and analyzes the data from the sensor to determine whether to initiate an alarm. The rate-of-rise heat function quickly detects a fast, flaming fire. The fixed-temperature heat function detects fire when the air temperature near the detector exceeds the alarm point. The KI-HFD is an intelligent fixed-temperature heat detector that contains a fixed-temperature heat sensor rated at 135 OF (57.2 °C). It does not have a rate-of-rise function. The heat sensor moni- tors the temperature of the air in its surroundings and the detector analyzes the data to determine when the air temperature near the detector exceeds the device's alarm point. mpatibIewithVS.VMcontroIs .. woo t4jr \T 'iI-HFD shown Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next generation heat sensing technology 135 OF (57 °C) fixed temperature alarm point (HAD and HFD) 15 OF (8.3 °C) per minute rate-of-rise alarm point (HAD) Uses existing wiring Automatic device mapping Sensor Markings Provide Easy Testing Identification Up to 250 total devices per loop Non-volatile memory Electronic addressing Bicolor (green/red) status LED Cover marking for easy identification during testing Standard, relay, fault isolator, and audible mounting bases 50 foot (15.2 meter) spacing S853 0 Page lof4 DATA SHEET K850010647 Not to be used for installation purposes. Issue 1 Application The KI-HRD combination fixed temperature/rate-of-rise heat de- tector provides a 15 OF (9 00) per minute rate-of-rise heat sensor for the detection of fast-developing fires, as well as a 135°F (57°C) fixed temperature sensor for slow building-fires. The KI-HFD fixed temperature detector provides a 135°F (57°C) fixed temperature sensor for slow building-fires. Compatibility The KI-HRD detector is compatible with Kidde VS and VM series panels. Installation KI Series detector bases mount to North American 1-gang boxes, WO 3-1/2 inch or 4 inch octagon " .. boxes, and to 4 inch square elec- Self-locking tab trical boxes 1-1/2 inches (38 mm) (----------- . deep. They mount to European K . BESA and 1-gang boxes with 60.3 mm fixing centers See mounting LED Indicator base installation and wiring for ..: more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each KI Series detector constantly runs self-checks to provide important maintenance in- formation. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory. Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Accessories Detector mounting bases have wiring terminals that are acces- sible from the 'room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The KI-SB4, KI-RB4, and KI-1B4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the GSA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The KI-ABST mounts to a 4 inch square box only. KI-ABST/T/LF 1(1-SB KI-18 KI-RB GSA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED GSA-LED - The remote LED connects to the K1-SB or KI-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. GSA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - KI Series sounder bases are designed for use where localized or group alarm signaling is required. Kl-ABST bases provide sounder capability to KI Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. Kl-ABDT bases provide sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. Kl-ABLT bases provide 520 Hz low frequency sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. The KI-ABLT is suitable for ap- plications requiring low frequency audible tones. Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safe- guards with the local fire protection specialist. This detector does not sense fires in areas where heat cannot reach the detector. Heat from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector. This heat detector by itself does not provide life safety protec- tion Use this detector with ionization and/or photoelectric smoke detectors. This detector does not detect oxygen levels, smoke, toxic gases, or flames. Use this device as part of a broad-based life safety program which includes a variety of information sources pertaining to heat and smoke levels, extinguishment systems, visual and audible devices, and other safety mea- sures. Independent studies indicate that heat detectors should only be used when property protection alone is involved. Never rely on heat detectors as the sole means of fire protection. Page 2 of 4 DATA SHEET K85001-0647 Not to be used for installation purposes. Issue 1 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, KI-SB, Kl-SB4 This is the basic mounting base for Kidde KI Series detectors. The GSA-LED Remote LED.is supported by this Base. Term Description 1 Not Used 2 DATA IN/OUT (+) 3 Not Used 4 DATA IN)-) 4 Remote LED (-) 5 Remote LED (+) 6 Not Used 7 DATAOUT( - ) kLED 10 )ATA IN I DATA OUT (-I DATA IN 1+) DATA OUT (a) From Signature Controller To Next Device or Previous Device Isolator Detector Base, KI-IB, KI-I134 This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED. OUT (-) OUT (+) next isolator down the From Signature Controller IUDO tt.) piuvium LI 10 or Previous Device To Nest Device line with power Term Description 1 Not Used - when the isolator next 2 DATA IN/OUT (+) 3 DATA IN(-) to the short closes, it reopens within 10 4 Not Used msec. 5 Not Used 6 DATA OUT)-) The process repeats beginning on the 7 Not Used other side of the loop controller. Relay Detector Base. KI-RB. KI-RB4 This base includes a relay. Nor- mally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The KI-RB DAT can be operated as a control relay if programmed to do so at DATA IN DATA OUT tnt To Next Device the control panel. The relay base From Signature Controller 01 Previous Device I does not support the GSA-LED Term Description 1 Normally Open Remote LED. CONTACT RATING I I 2 DATA IN/OUT 1.0 Amp ut 30 VDC 3 Common (Pilot Duty) I 4 DATA IN 5 Not Used i 6 Normally-Closed 7 DATA OUT)-) I Audible Sounder Bases, Fire Mode ABD7 ABS7 ABLT sounder bases KI-ABDT, o o ©\ KI-ABLT: l K-ABST, KI-ABLT: Jumper cuts Output Mode Default = Fire Volume Setting Cut/remove jumper for Default = High Fire plus CO Cut/remove - jumper for KI-ABST: low dB Tone Setting [_ oan __________________ j DATA- DATA- Default = Temporal isuour Cut/remove jumper for Steady III Not Used 24 Vdc in From power supply - - 24 Vdc Out or previous base ____________ - + To next base or EOL relay Data in , I Data out From KI Device Controller to next KI Series device or previous device The isolator operates as follow - a short on the line causes all lators to open within 23 ms - at 10 msec intervals, beginning on one side of the Class A DA1 circuit nearest the loop controller, the isolators Page 3 of 4 DATA SHEET K85001-0647 Not to be used for installation purposes. Issue 1 Dimensions idde .................... . ......... Technology that saves lives i An. IX Contact Uikdde.flre@fs.utc.com & j Web: kidde.corn/engineeredsysterns 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. All rights reserved. Specifications KI HRD KI HFD Operating voltage 15.20 to 19.95 VDC — Normal op nterating curre 51 pA Alarm current 68 _p A'' Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Rate-of-rise rating 15°F/rnin(8°C/rnin)T NA Fixed temperature rating 135°F (57.2°C). Actual alarm point 129 to 141°F (53.9 to 80.6°C). Maximum spacing 50ft. (15.2.m) centers Compatible bases See Ordering Information Compatible detector testers Testif ire 1000, Testifire 2000 Testifire 2000 Operating environment 32 to 100°F (0 to 38°C), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White Storage temperature -4 to 140°F (-20 to 60°C) Agency[ /UL6T0, UL 521 ICAN/ULC-5530-M91,UL 521 Ordering Information Catalog . Ship Wt. Number Description Ship (kg) KI-H RD Intelligent fixed temperature/Rate-of-rise heat detector — - 04 (0.16) Kl-HFD Intelligent fixed temperature heat detector Compatible Bases Kl-SB Detector Mounting Base - Standard KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt Kl-RB Detector Mounting Base w/Relay 0 2 09 Kl-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt KI-IB Detector Mounting Base w/Fault Isolator Kl-lB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt KI-ABST Audib le (Sou nder) Bas e for Fire Detectors KI-ABLT ________Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) Kl-ABDT Audible (Sounder) Base for CO and Fire Detectors GSA-LED Remote Alarm LED (not for EN54 applications) -- S (supplied - 0.1 (004) GSA-TS Trim Skirt ( op ti ona l for on n 4-inch bases) Page 4 of 4 DATA SHEET k85001 -0647 Not to be used for instaIlationpurposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1657:0333 Page 1 of 2 CATEGORY: 7270 - HEAT DETECTOR LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-HFD, SIGA-HRD, *SIGAH2D *SIGI-HFD, *SIGIHRD *KIHFD *KIHRD and *KIR..HD Analog Addressable Heat Detectors. Model SIGA-HFD is a 135°F fixed temperature heat detector. Model SIGA-HRD is a combination 15°F rate of rise/135°F fixed temperature heat detector. Models S IGA-HFD, SIGA-HRD, *SIGAH2D *SIGI-HFD, *SIGIHRD *KI-HFD, *KIHRD and *KIRHD Analog Addressable Heat Detectors. Model SIGA-HFD is a 135°F fixed temperature heat detector. Model SIGA-HRD is a combination 15°F rate of rise/1 35°F fixed temperature heat detector. *Models SIGI-HFD and SIGI-HRD are similar to Models SIGA-HFD and SIGA-HRD except for isolation circuitry. *Models KI-HFD and Kl-HRD are identical to Models SIGA-HFD and SlGA-HRD except for trade name. *Model KIR-HD is similar to Model SIGA-HFD except for control panel compatibility. Model SIGA-H2D is similar to Model SIGA-HFD except has a programmable threshold. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-HFD, SIGA-HRD, SIGA-1-12D, SIGI-HFD and SIGI-HRD are under the Edwards brand. *Models KI-HFD, Kl-HRD and KIR-HD are under the Kidde brand. APPROVAL: Listed as an analog addressable heat detectors. *Models KI-HFD and KI-HRD are for use with listee's Models VS1, V52 and V54 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657-.0309) fire alarm control units. *Models SIGA-HFD, SIGA-HRD, SIGA-1-12D, SIGI-HFD, SIGI-HRD, are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); i064, i0500 and i01000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Rev 02-15-18 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct kv' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2026 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ListingNo. 7270-1657:0333 Page 2 of 2 *Model KIR-HD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control unit. Models SIGA-HFD, SlGA-HRD, SIGA-H2D are for use with listee's bases; Models SlGA-SB, -SB4, -RB, -R134, -lB, -1134 (CSFM No. 7300-1657:0120); SIGA-AB4G (CSFM No. 7300-1657:0222); SIGA-AB4GT (CSFM No. 7300-1657:0307) and SlGA-AB4G-LF (CSFM No. 7300-1657:0322). *Models SlGl-HFD and SlGl-HRD are for use with listee's bases; Models SlGl-AB4G (CSFM No. 7300-1657:0222); SlGl-AB4GT (CSFM No. 7300-1657:0307) and SlGl-AB4G-LF (CSFM No. 7300-1657:0322). *Models Kl-HFD,1Kl-HRD and KIR-HD are for use with listee's bases; Models Kl-ABST (CSFM No. 7300-1657:0222), Kl-ABDT (CSFM No. 7300-1657:0307) and Kl-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires, June 30, 2020' Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division GSA-MCT2 KDDE Calaiog t> Intelligent Input-Output 11 C United Technologies IM -W-PERM Technology that saves lives Input Modules GSA-CT1, GSA-CT1 HT, GSA-CT2, GSA-MCT2 MEA * 7300-1483: 0115 S3424 Overview The GSA-CT1 Single Input Module, GSA-CT1 HT High Tempera- ture Single Input Module and GSA-CT2/GSA-MCT2 Dual Input Modules are intelligent analog addressable devices used to con- nect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The GSA-CT1, GSA-CT1 HT and GSA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The GSA-CT1 HT module operates at an expanded temperature range of 32 OF to 158 OF (0 °C to 70°C) for those applications requiring more extreme environmental temperature variation. The GSA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the GSA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. GSA-CT1HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET K85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from Kidde Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. I nstallation GSA-CT1, GSA-CT1 HT and GSA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWO (2.5 mm2 to 0.75 mrire size. Compatible electrical box Wall plate, white (1-gang) Status LED viewing ports • 13 GSA-MCT2: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the GSA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWO (2.5 mm2 to 0.75 mm2) wire size. UlO Motherboard 6-32 Sell-tapping . screws Plug-in (UIO) captive Module screws -- #6 Flat washers Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the Signature Pro- gram/Service Tool. Kidde recommends that this module be installed according to lat- est recognized edition of national and local fire alarm codes. Application The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is de- termined by their sub-type code or 'Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the GSA-CT1. Two per- sonality codes can be assigned to the GSA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on GSA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. Page 2of4 DATA SHEET K850010241 Not to be used for installation purposes. Issue 1 DATA IN (+)> DATA OUT (+) 1 DATA iN (-)> . DATA OUT (-) From Signature Controller To Next Device or Previous Device GSA-CT2 I I Oypioi NO initi050g Deuce I Inpes 2 nput I < .1. I I .. I I .1_ I uLluLcListed i T T T 57KW EOL YkYA MC'S UiciRi series motherboard jz "I. Other meduies my require B En No connections or jumper seOings ]nequinedfonMCr2. GSA-MCT2 ULIULC Listed 47KW EOL Dotoin+ Signotune S Orcuis Dote Out + O - KWn LEO iNorrcOii Rod LED coNed Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference Wire Size - Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1 .00 mm2) 4,000 ft (1219 m) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) Typical N.C. Initiating Device Typical N.C. initiating Device INPUT] INPUT 2 L\ style B (Class B) 182 1 __ TB2 8 7 UL/ULC Listed 47M EOL UL/ULC Listed UL Listed Ted LED Green LED (Alarm/Active) 0 0 (Normal) Ted LED II Green LED 4 3 2 I (Alarm/Active) ( ., (Normal) TB] kth#flUTh1Il TB] f DATA iN(+))- I DATA OUT 1 DATA IN (-) )s— . DATA OUT () From Signature Controller I To Next Device or Previous Device GSA-CT1, GSA-CT1 HT NOTES A Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2 ) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. A Maximum 10 Vdc @350 JA The GSA-UI06R and the GSA-U102R do not come with T814. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform. They are compatible with VM, and VS Series control panels. Page 3 of 4 DATA SHEET K85001-0241 Not to he used for installation purposes. Issue I l('dd f Description Technology that saves lives Contact us... Specifications Catalog Number Type Code Address Requirements Operating Current GSA-CT1HT SA-CTf GSA-CT2lGSA-MCT2 Single Input Module Dual Input Module 48 (factory set) Four sub-types 49 (factory set) Four sub-types (personality codes) are available Uses One Module Address Uses Two Module Addresses Standby = 250pA;. Standby = 396pA; Email: kidde.fire@fs.utc.com 'Activated = 400pA Activated = 680pA Web: kidde.com/engineeredsystems Operating Voltage 15.2 to 19.95Vdc(19Vdcnominal) -* 1016 Corporate Park Drive Construction High Impact Engineering Polymer Mebane, NC 27302 Mounting North American 21/2 inch (64 mm) deep one-gang box- UIO2R/6R/6 Kidde is a registered mark in the United States and other countries, es and 11/2 inch (38 mm) deep 4 inch square boxes Motherboard with one-gang covers and GSA-MP mounting plates © 2018 Walter Kdde Portable Equipment. Operating Environment I 32°F to 158°F I 32°F to 120°F (0°C to 49°C) All rights reserved. ........................................ .°--¶?9] C) _ Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Both LEDs - Glow steady when in alarm Compatibility Use with Signature Loop Controller _________ Aaencv Listinas UL, ULC, MEA, CSFM Ordering Information Catalog Description Ship Wt. Number lbs (kg) GSA-CT1 Single Input Module — UL/ULC Listed 0.4(0.15) GSA-CT1HT Single Input Module High Teperature Operation UL/ULC Listed 0.4(0.15) GSA-CT2 Dual Input Module - ULJULC Listed __________ 0.4(0.15) GSA-MCT2 Dual Input Plug-in (UlO) Module — UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) GSA-UI02R Universal Input-Output Module Board w/Riser Inputs 0 32 0 15 — Two Module Positions GSA-UIO6R Universal Input-Output Module Board -w/Riser Inputs 0.62 (0.28) — Six Module Positions _________ GSA-UIO6 Universal Input-Output Module Board — Six Module Positions 0.56 (0.25) MFCA Multifunction Fire Cabinet - Red, supports Signature Module 7.0 (3.1) Mounting Plates GSA-MB4 Transponder Mounting Bracket (allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) ______ GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) r) Page 4 of 4 DATA SHEET K85001-0241 Not to be used for installation purposes. Issue 1 A. \ W:: - GSA-MCR --- MEA * 7300-1483: 0115 S3424 Standard Features Provides one no/nc contact (GSA-CR/MCR) Form "C" dry relay contact can be used to control external ap- pliances such as door closers, fans, dampers etc. Allows group operation of sounder bases The GSA-CRR/MCRR reverses the polarity of its 24 Vdc out- put, thus activating all Sounder Bases on the data loop. Plug-in (UlO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. g,,,o United Technof ogles KIDDE: CiaIcq Intelligent Input/Output [7dmpati6le Technology that saves lives Control Relay Modules GSA-CR, GSA-MCR, GSA-CRR, GSA-MCRR Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (U10 versions, or standard 1-gang mount versions. The GSA-CR/MCR Control Relay Module provides a Form C" dry relay contact to control external appliances such as door clos- ers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board micro- processor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the GSA-CR/MCR relay activates the normally open or normally-closed contact. The GSA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of GSA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the GSA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (GSA-CR and GSA-CAR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is re- quired. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (GSA-MCR and GSA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are avail- able. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclo- sures. Page 1 of 6 DATA SHEET k85001 -0239 Not to be used for installation purposes. Issue 1 Installation GSA-CR and GSA-CRR: modules mount to North American 21/2 inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) ' 5• 'S S.' Status LEDs LED viewing ports • 5' GSA-MCR and GSA-MCRR: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard 6-32 Self-tapping screws :FPlug-in (L110) >CaptivE #6 Flat washers Cabinet or electrical enclosure Application The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (GSA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp © 24 Vdc; 0.5 amp © 120 Vac (or 0.25A © 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configura- tion is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (GSA-CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp © 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform. They are compatible with VM, and VS Series control panels. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory. The loop controller identifies each device on the loop and assigns a soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Kidde recommends that this module be installed according to lat- est recognized edition of national and local fire alarm codes. Page 2 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes. Issue 1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed Green LED (Normal) DATA OUT (+) DATA To Next Device 4 2 1 TB1 I DATA IN (+) ) 1. DATA IN(-) > From Signature Controller or Previous Device GSA-CR Control Relay Normally Open Common Normally Closed I j I 1234 Data ln1 4 H •ir&i VA WIIi*ul1 ii + Data Out Notes Refer to Signature Loop Controller Installation Sheet for wiring specifications. NFPA 72 requires that the GSA-CR/GSA-MCR be installed in the same room as the device it is controlling. This requirement may not apply in all markets. Check with your local AHJ for details. The GSA-U106R and the GSA-U102R do not come with TB1 4. The GSA-U106 does not come with TB8 through TB13. Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). Green LED (Normal) Red LED (Active) No connections required for NCR. Other modules may require connections. GSA-MCR Control Relay Page 3 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes. Issue 1 . For normal operation CT1 — For General Fire Alarm Operation L1 L—FFL MCRR ho(e) series motherboard ]4, No connections required for T814 MCRR. Other modules may require connections. S I Green LED (Normal) I / Red LED (Active) / 1 No connections required for 1B15 MCRR. Other modules may 1 2 3 4 I require connections. Optional MCRR or MCR for disabling/disconnecting an audible base. No connections required for MCRR. Other modules may require connections. Signature — Data Data Out Circuit + L UL/ULC Listed 24Vdcpower — F or i supply 1234 Green LED (Normal) Red LED (Active) Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1 .50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. AB4G AB413 AB413 Audible Base Audible Base Audible Base Listed 24 VDC Nominal Power Supply Signature Controller for disabling/disconnecting GSA-MCRR sounder base GSA-CAR Schematic P. In POuer 0..? POGrity Remrses - - Pd'en dct4oted Z1I GSA-MCRR Schematic :2 I— 0 z Audible 0 - = Doses + • < < < mu, 000 0 '6254A-003 EOL Relay required for supevision Notes /\ Refer to the Signature controller installation sheet for wiring. One Pair of wires (24 Vdc power). A One Pair of wires (Signature Data). Single Wire (24 Vdc power). The GSA-U106R and the GSA-U102R do not come with TB 14. The GSA-U106 does not come with T128 through A Supervised and power-limited. 8 If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG (2.5 mm2)wire; Minimum #18 AWG (0.75 mm2 ). 10 End-of-Line Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be "T-tapped." Page 4 of 6 DATA SHEET K85001-0239 Not to he used for installation purposes. Issue 1 Specifications Catalog Number GSA-CRJ [GSACRRi GSA-MCRR Description Control Relay I Polarity Reversal Relay Type Code Personality Code 8 (Factory Set) j Personality Code 8(Factory Set) Address Requirements Uses 1 Module Address - Operating Current Standby = 75 pA Activated = 75 pP_______ __________ Operating Voltage - 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C, 2 Amps © 24 Vdc (pilot duty), 0.5 Amps © 120 Vac and 0.25 Amps © 220 Vac (220 Vac is non-UL). Not rated for capacitive loads. Mounting North American 2½ inch Plugs into U102R, UlO6R or North American 2½ inch Plugs into UI02R, U106R or (64 mm) deep 1-gang boxes U106 Motherboards (64 mm) deep 1-gang boxes U106 Motherboards and 11/2 inch (38 mm) deep and 11/2 inch (38 mm) deep 4 inch square boxes with 4 inch square boxes with 1-gang covers and GSA-MP 1-gang covers and GSA-MP mounting plates mounting plates Construction & Finish High Impact Engineering Polymer Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation i On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings I UL, ULC, CSFM, MEA Ordering Information Catalog Number Description Ship Weight - lbs GSA-CR Control Relay Module (Standard Mount) 0.4 (0.15) GSA-MCR Control Relay Module (UlO Mount) 0.18(0.08) GSA-CRR Polarity _Reversal Relay Module (Standard Mount) 0.4 (0.15) GSA-MCRR Polarity Reversal Relay Module (UIO Mount) 0.18 (0.08) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang ______ ______ 1(0.6) 27193-16 Surface Mount Box - White, 1-gang 1(0.6) GSA-Ul02R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) GSA-U106R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) GSA-U106 Universal _Input-Output _Module Board - Six Module Positions 0.56 (0.25) GSA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1) GSA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) GSA-MP1 Signature Module Mounting Plate, 1_footprint _____ ______ 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 5 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from Kidde is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output mod- ules, network and non-network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The mi- croprocessor in each Signature device provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self- checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signa- ture Program/Service Tool. The information stored in device memory includes: Device serial number, address, and type Time and date of last alarm Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping -The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configu- ration and are indicated during device mapping. Standalone Operation - A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone (degrade) mode. If Sig- nature loop controller CPU communications fail for more than four seconds, all devices on that circuit go into standalone mode. The circuit acts like a conventional alarm receiving circuit. Each Signature device on the circuit continues to collect and analyze information from its slave devices. When connected to a panel utilizing standalone operation, modules with their "personality" set as alarm devices (IDC) will alarm should their slave alarm-initiat- ing device activate. K i d d e Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: k/dde.com/engineeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. Al rights reserved. Page 6of6 DATA SHEET K850010239 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1483:0115 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GSA-CCI, GSA-CC2, GSA-CT1, GSA-CT2, GSA-CR, GSA-CRR, GSA-UM, GSA-MMI, GSA-WTM, GSA-IM, GSA-MCC2, GSA-MCT2, GSA-MCR, GSA-MCRR, GSA-MAB, GSA-MCC1, GSA-MDM remote transponders; Models GSA-U106, GSA-U106R and GSA-Ul02R motherboards. Models GSA-CC1S and GSA-MCC1S Auto-Sync Output Modules. Models MFC-A and MEC-AD enclosures. Models GSA-MP1, GSA-MP2 and GSA-MP2L mounting plates. Model GSA-CR2 Control Relay Module. *GSACRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote transponders for use with separately listed compatible fire alarm control units. XLF: 7300-1657:0121 *Rev. 03-29-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020' Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting platelor ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L.Series o:ers the most versatile and easy-to-use line of ho:-ns, strcbes, and horn strobes in the industry with lower current draws and rnoce• aesthetics. With white and red plastic housings, wall and celing rnojnting options, System Sensor L-Series can meet virsually any appication requirement. The entire L-Series product li-se c' ceiling-mount strobes and horn strobes include a variey of featues that increase their application versatility while simplfying insiallatioi. All devices feature a plug-in design with minimal itrusion ito :ha back box, making installations fast and foolproof whIe virtual :y eliminating costly and time- consuming ground faults. To further simplify instaliatior, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onbosrd short:nç s:ring, installers can test wiring continuity before the device is lnStai ed. Installers can also easily adapt cev es to a suit a wide range of application requirements using feld-selectable candela settings, automatic selection of 12- or 24--ic-It operation, and a rotary switch for horn tones with two voljmslections. Agency Listings SIGNAUNG 0 LISTED APPROVED S5512 FM approved eacepl 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 AVDS868-02 • 12/01/2017 • Page 3 L-Series Specifications General [-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SyncoCircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have held-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for lire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate . 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6,9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDSB68.02 • 12101/2017 • Page 2 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR Candela 151 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA DC Input RMS), Ceiling 8-17.5 Volts 15cd 30cd Horn Strobe, Candela 16-33 Volts 15cd Range (15-177 30cd cd) 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 .71 90 143 fl65 187 217, 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 -. 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.lKTemporal High 108 135 179 200 225 255 289 3.lK Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal LOw 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 2.47 (62.7 mm) 1.37"(34.8 mm) 6.83 di (173n 6.92" Ili- (1 75. (64 mm) L-Series Dimensions A0545.00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 .01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Ceiling Horn Strobes -- Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red 'PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT FC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 'Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to changewithoutnotice. Visit systemsensor.corn 02017 System Sensor. $ SEIJSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product inioornaiioe, irrciudirrg the latest version 01 this data sheet, AVDS868-02 • 12/01/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SçwCand SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-02, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WailTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listees data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expire. June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division .4 Listing No. 7125-1653:0504 Page 2of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/f*r setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR® Indoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Agency Listings SIGNALING 0 LISTED APPROVED $5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383, 3057072 The System Sensor L-Series offers the most v9:satile and easy-to-:i.se line of horrs, strobes, anc horn strobes ii the industry with lower current drais and modern aesthetics. wm white and red plastic housings, starodäi and compact devices, ani plain. FIRE, and FUEf3O-printed cevices, System Sensor L-Series can fleet virtually any application requirenent. The L-Saries line of wa 1-mount horns, strobes, and born strobes include a variety of fea:Lres that increase their app ic:aticn versatility while simplifying inst&laton. A6 devices feature pIL.g-in designs iith mirmal intrusior irno the back box, ma king installations fast and tooproof while virtually elimiratirg cosly and ne-consuming ground faults. To further simplify inatallation and protect devices from construcior: Jamaga, the L-Series uthizes a universal mounting plate for all models with an onboad shorting sprng, so installers can test wring continury before thecevice is nstalled. Installes can also easily adapt devices to a suit a voice range of application requirements usng fie:d-selectabla oandela settir:gs. automac selection of -2- or 24-volt 3pera.on, and a rotary switch 10r horn, tones with to volume. selecoions. AV00865-05 • 2/22/2016. • P.ge 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, [-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-s gnaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to U[ 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 1< 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all t ie zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16,5 to 33 V (24 V nominal) lnputTerminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6'T x 4.7"W x 1.91"D (143 mm [ x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6'L x 4.7"W x 1.25"D (143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45W x 1.25" D (133 mm Lx 88 mm W x 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AV05865-05 - 2/2212018 - Page 2 iulu ICurrenta ii 1 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121, 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 bC Input. 8-1Z5Volt' 15cd 30cd c16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121. :142 162 1196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.lKTemporal High 81 105 155 177 196 234 284 3.lKTemporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAG voltage is held constant, the horn output remains constantly on. AV05565-05 • 2/22/2018 • Page 3 L-Series Dimensions 88 Mm rrrn A0545.00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL - 4.70 - (11.94 cm) 1.91" (4.85 cm) Zcm) 1.25" (3.18 mm) ( Strobe, Horn Strobe A0550-00 1.25' - 4,82 - 32 mm (12.24cm) (4.69 cm) LIP 5.78' :14.68 cm) ED L So.. B A0554.OI A0549.00 Wall Surface Mount Back Box SBBRL/SBBWL Horn L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horns* TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover), All -SF models have "FUEGO" marking on cover, All -ALERT models have "ALERT" marking on cover. *Hornonly models are listed for wall or ceiling use. HRL* Horn, Red HWL5 Horn, White HGRL* Compact Horn, Red HGWL* Compact Horn, White Accessories "S TEM 3825 Ohio Avenue • St. Charles, IL 60174 @2018 System sensor. SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change asithout notice. Visit systemsensor.corm for current product information, including the latest version at this data sheet. www.systemsensor.com Avo5865.05 • 2/22/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:6563 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: 'System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RLj P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *4\f Wall Horn Strobes PC2RL,JC2WL, *PC4RL and *PC4WL ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2019 Listing Expires June 30,2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires 'June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TELGUARD AMETEK TG-7FS LTE-V CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS COMMERCIAL FIRE PRODUCT FEATURES I- Certified for use on Verizon's LTE network for sunset-free installations. I Meets UL 864 requirements for sole, primary or backup path communications. 1- Minimizes false alarms by providing dual paths for self-test. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS CDMA transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LTE-V can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new five or sixty minute supervision modes. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. TG-7FS LTE-V CELLULAR ALARM COMMUNCATOR FOR LTNETWORKS 04 TELGUARD AMETEK ((I t)) LLTE F!nei !Ki f L,ndline (Optional) Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. For the most current product specifications and UL Listings visit www.Telguard.com. SIGNALING ELECTRONIC SECURITY (IlilUl] ASSOCIATION SECURITY Executive Strategic Partner LISTED NFPA INTERNATIONAL Gold UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems verizon' network certified Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300• Atlanta, GA 30339 • USA 800.229.2326 1 telguard.com Copyright ©2019 Telguard, a Business Unit of AMETEK, Inc. • All Rights Reserved 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0500 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com Model TG7LVO02, TG7LVA02, TG7LVF02, *TG7UBLV and TG7 KIT digital cellular communicators, digital cellular radio alarm transmission device used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations 120 Vac In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as digital cellular radio alarm transmission device. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: NOTE: *Rev 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division FFC7-6~2-0 -00S-9 Page 1 of 4 Record of Completion Name of Protected Property: Address: 2819 Loker Ave Carslbad, CA 9210 Rep. of Protected Prop. (Name/Phone): Paul Alaksin / 760-603-5174 Authority Having Jurisdiction: City of Carsbad Fire Prevention Address/Phone Number: 1635 Faraday Ave Carlsbad CA 92008 I 760-602-4660 1. Type(s) of System or Service NFPA 72, Chapter 3 Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 3 Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: - Multiple: Quantity of speakers installed: Quantity of speaker zones: - Quantity of telephones or telephone jacks included in system: - NFPA 72, Chapter 4 Auxiliary Indicate type of connection: Local energy: _Shunt: - Parallel telephone: - Location and telephone number for receipt of signals: NFPA 72, Chapter 4 Remote Station Alarm: Supervisory: NFPA 72, Chapter 4 Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: Indicate how alarm is retransmitted: x NFPA 72, Chapter 4- Central Station The Prime Contractor: Nova Security Central Station Location: 14231 Garden Road, Poway CA 92064 Means of transmission of signals from the protected premises to the central station: - McCulloh - Multiplex - One-Way Radio X Digital Alarm Communicator - Two-Way Radio - Others Means of transmission of alarms to the public fire service communications center: Cellular System Location: MPOE Room Page 2 of 4 Organization Name/Phone Representative Name/Phone Installer Nova Security Andy Jordan 619-448-3008 Supplier Kidda Service Organization Nova Security Andy Jordan 619-448-3008 Location of Record (As-Built) Drawings: Document storage container at FACP Location of Owners Manuals: Document storage container at FACP Location of Test Reports: Owner A contract, dated 5.22.2020 , for test and inspection in accordance with NFPA Standard(s) No(s). NFPA-72 dated , is in effect. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by Andy Jordan on 6.4.2020 , includes the devices shown below, and has been in service since 6.4.2020 X NFPA 72, Chapters ()0K3CI0rcie all that apply) X NFPA 70, National Electric Code, Article 760 X Manufacturers Instructions Other (specify): Signed: Andy Jordan Organization: Nova Security Date: 6.4.20 Record of System Operation All operation features and functions of this system were tested by Andy Jordan on 6.4.2020 , and found to be operation properly in accordance with the requirements of: XNFPA 72, Chapters ()133(X09rcle all that apply) XNFPA 70, National Electric Code, Article 760 X Manufacturers Instructions Other (specify): Signed: Organization: NovaSecurity Date: Alarm-Initiating Devices and Circuits (use blanks to indicate quantity of devices) MANUAL (a)1 Manual Stations X Noncoded, Activating ______Transmitters (b) Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: X Partial:_________ (a) 5 Smoke Detectors Ion X Photo 6.4.2020 Coded (b) 5 Duct Detectors br (C)2 Heat Detectors FT (d) 4 Sprinkler Water flow Switches: (e)_______ Other (list): X Photo RR Transmitters XFT/RR RC - Noncoded, Activating ______Coded Page 3 of 4 5. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a)______ Coded Stations (b)______ Noncoded Stations, Activating Transmitters (C) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations NOTE: Combination devices recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) 5 Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches, Activating 5 Transmitters (b)______ Building Temperature Points (C)______ Site Water Temperature Points (d)______ Site Water Supply Level Points Electric Fire Pump: (e)______ Fire Pump Power (f) _Fire Pump Running (g)______ Phase Reversal Engine-Driven Fire Pump: (h)______ Selector in Auto Position (i) Engine or Control Panel Trouble U) _ Fire Pump Running Engine-Driven Generator: (k) _ Selector in Auto Position (I) _ Control Panel Trouble ______Transfer Switches ______Engine Running Other Supervisory Function(s) (specify): 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: 30 Types and quantities of alarm indicating appliances installed: (a)______ Bells Inch (b)______ Speakers (c)______ Horns (d)_______Chimes (e)3Other: WFHornStrobes 181 Visual Signals Type: Strobe 85 with audible 96 wlo audible I Local Annunciator 7. Signaling Line Circuits Quantity and Style (see NFPA 72, Table 3-6) of signaling line circuits connected to system: Quantity: 1 Style: 7 8. System Power Supplies Primary (Main): Nominal Voltage: I20VAC Current Rating: 20Amp Overcurrent Protection: Type: Breaker Current Rating: 20Amp Location: House Panel Circuit #2 Secondary (Standby): - - A Page 4 of 4 X Storage Battery: Amp-Hour Rating 18 amps X Calculated capacity to drive system, in hours: X 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: Emergency System described in NFPA 70, Article 700 Legally Required Standby System described in NFPA 70, Article 701 Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software Operating System Software Revision Level(s): 3.65 Application Software Revision Level(s): 3.65 Revision Complete by: Andy Jordan Nova Security (name) (firm) 10. Comments: This completion certillct is for mplete, system upgrade L -1 _- (signed) for Central Station or Alarm Service Company (title) Project Manager (date) 6.4.2020 Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA Standard(s): Annualy System deviations from the referenced NFPA standard(s) are: (signed) for Central Station Alarm Service Company (title) Project Manager (date) 6.4.2020 U om of the rn(s) satisfactory test(s) witnessed (if required by the Authority Having Jurisdiction): cpi7 ed) Repre6ptdive of the Authority Having Jurisdiction (title) (date) See aproved plans for AHJ mark Reprinted with permission from NFPA 72, National Fire Alarm Code, Copyright © 1999, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject which is represented only by the standard in its entirety. Distributed by: AFM - P.O. Box 951807 Lake Mary, FL 32795-1807 Phone —(407) 322-6288 Fax—(407) 322-7488 Web—www.afaa.org