HomeMy WebLinkAbout2839 LOKER AVE E; ; FA160015; Permit12/8/2020 F4160015 Permit Data City of Carlsbad Fire Alarm Permit 2839 LOKER AV Job Address: EAST Permit Type: FALARM Parcel No: 2090831300 Lot #: 0 Reference No.: Permit No: FA160015 Status: ISSUED Applied 4/7/2016 Approved: 5/5/2016 Issued: 5/5/2016 PC #: Inspector: Project Title: LEIGH AEROSYSTEMS CORP REPLACE EXISTING FACU FOR THE PURPOSE OF CHANGING THE CENTRAL STATION MONITORING MEHTOD FROM PHONE LINES TO CELLULAR COMMUNICATOR. REPLACE THE REMOTE ANNUNCIATOR TO BE COMPATIBLE WITH THE NEW FACU. ADD A SMOKE DETECTOR AT THE FACU. CONNECT TO EXISITNG HORN/STROBES, MANUAL PULL STATIONS, WATERFLOW AND OS&Y. THIS DEDICATED FUNCTION FIRE ALARM CONTROL UNIT WILL REPORT TO A CENTRAL STATION. Applicant: BAY ALARM COMPANY 4883 RONSON CT SUTE C SAN DIEGO, CA 92111 714-719-9334 Owner: RUTHS BOYS L P C/O ANTHONY CHANIN 15250 VENTURA BLVD #1014 SHERMAN OAKS CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 362 L 0 362 0 1/1 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 FA16 006 PROTECTED PREMISE Leigh Aerosystems Corp 2839E. Loker Ave. Carlsbad, Ca 92008 MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1 (800)470-1000 Contractor License # 880138 DF-52416:D • A3-20 MS-5UD(E)/MS.1 OUD(E) Series Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel (a Fure•LuTGALarms by Honeywell General The MS-511.111D-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-11 OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-I0UD-7E offers the same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). Style B (Class B) IDC (Initiating Device Circuit) - MS-5UD-3 - five IDCs. - MS-10UD-7 - ten IDCs. Style V (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-1OUD-7 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS-i OUD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-10UD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:D • 07/26/2010 - Page 1 of 4 Door = 16.821" (42.73 cm) Backbox = 16.65" (42.29 cm) Right Side USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] Top Depth = 5.207" (13.23 cm) H F' Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) Left Side Bottom Cabinet Measurements Page 2 of 4— DF-524160 • 07/26/2010 Minimum Battery Size: 7 AH. Initiating Device Circuits - T134 (and TB 6 on MS-i OUD-7 only): Alarm Zones 1 - 5 on TB 4 (MS-5UD-3 and MS-10UD-7). Alarm Zones 6- 10 on T136 (MS-10UD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits - T135 (and TB 7 on MS- 1OUD-7 only): Four NACs Operation: Style Y (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0A for MS-10UD-7(E), 3.0A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices. Form C Relays - T138: Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - T139: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - T132: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.71K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-51JD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-i OIJD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to J7 on the MS-10UD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPA TIBLE ANNUNCIA TORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-52416:D • 07/26/2010 -Page 3 of 4 SYSTEM SPECIFICATIONS I System Capacity Annunciators ......................................................................8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.0 A MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26° (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TA-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: —20.00" (50.80 cm.) high —22.5" (57.15 cm.) wide - 8.5" (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:0214 MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINERINS & MANIMM111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the iJ.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:0 • 07/26/2010 ANN-80 80-Character LCD Serial Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4° square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Use ANN-5B80K1T for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble df-52417:c B-go FlreLn-e®Atarms by Honeywell Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375 (13.65 cm.) high x 6.875 (17.46 cm.) wide x 1.375 (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. df-5241 7:c 05/22/09 Pagel of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power-limited. = TBI ANN-BUS Device ORDERING OPTIONS: ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80K1T-R: Red surface mount backbox with angled wedge. ANN-SB80K1T-W: White surface mount backbox with angled wedge. [IJIIJIW 12345678 FACP Wiring to ANN-BUS Device FireLite® Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEENN9 A MANUFACTUMIC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire Life Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 df-52417:c 05/22/09 LirIiTvL I IPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel (FACP) that has a built-in dialer. This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include: Cellular only, IP only, or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-1 and 800 PLUS services, providing true redundancy and multipath message delivery. Alternative communication methods are critical in the market- place due to VolP (Voice over IP), migration from POTS (Plain Old Telephone Service) and growth of digital radio networks. The IPGSM-4G's single path communications solution allows one technology to be used (either IP or cellular) to provide the appropriate connectivity to a central station. For added reliabil- ity, our exclusive dual path solution allows both technologies (IP and cellular) to be used together for maximum survivability or for local jurisdiction requirements that specify a dual tech- nology system. The IPGSM-4G is designed to operate over the most common cellular networks including 2G, 3G and 4G. Its multi-GSM plat- form technology automatically chooses the best available cel- lular signal in the area based on signal strength and seamlessly self-adjusts to maintain critical life safety communi- cation. In addition, it connects to any type of customer pro- vided Ethernet 10/100 base network connection (LAN or WAN), DSL model or cable modem. Our selectable reporting path feature allows the radio to be configured for a single or dual path solution as well as the appropriate supervision inter- vals based on NFPA 72 requirements. (See diagram below for selectable paths and supervision timing intervals.) Selectable Path Description Supervision Times 2010 GSM Single Path (cellular only) 5 minutes 2010 IP Single Path (IP only) 5 minutes 2010 IP & GSM Dual Path (IP and cellular) 24 hours 2013 GSM Single Path (cellular only) 1 hour 2013 IP Single Path (IP only) 1 hour 2013 IP & GSM Dual Path (IP and cellular) 6 hours Features Saves the cost of two dedicated phone lines. Single or dual path communications. (Can communicate to central station using cellular technology, internet or both. Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Multi-GSM platform compatibility for 2G, 3G and 4G net- works. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) GPRS (2G). Selectable reporting paths and supervision intervals to meet NFPA 72, chapter 26 requirements. (Compliant with NFPA72 2010 and 2013 supervision requirements.) Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL modem or cable modem. Data transmits over standard contact-ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit). Supports both dynamic (DHCP) or Public and Private Static IP addressing. Built-In Power Supply module: On board charging circuit design accommodates back-up battery. Includes primary power and battery supervision. Diagnostic LEDs: Signal strength and status indicators. Reliable connection: IP and GSM connection tested every day. QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including when message was received, signal strength, and message path used. 7720P Hand-held programmer for easy setup. Operation When an event occurs, the Fire Alarm Control Panel goes off hook to dial the central station. The IPGSM-4G Dialer Capture Module detects the oft-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel. The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss-oft after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent on configuration). Easy to Program The IPGSM-4G communicator can be pre-programmed using the 7720P programmer to enter all central-station information. This is saved to the IPGSM-4G communicator panel memory. When the IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the AlarmNet receiver. For most installations, the only required parameters are: Primary City ID (two digits) obtained from your monitoring station. Primary Central Station ID (two digits) obtained from your monitoring station. Primary Subscriber ID (four digits) obtained from your mon- itoring station. Communication Modules MAC ID, and MAC CRC number located on outside of box, and inside of the module. All of these parameters are assigned by the monitoring station. NOTE: Some assembly is required. See Installation and Setup Guide #800-12454 for full details. Fire Communicator Capability The IPGSM-4G is compatible with fire panels that use the Contact ID communications format as described in the SIA DC-05 standard. AlarmNet Honeywell's AlarmNet has been the nationwide leader in alarm communications technology since 1986. A reliable alter- native for the transmission of alarm signals, our radio network provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes sigrals from pow- erful servers in multiple locations equipped with 24/7 infra- structure support. The AlarmNet network consist of redundant hardware servers, hot back-up databases and generators with battery back-up at all locations to ensure continuity of service. Signals from Alarm-Net are transmitted to the central station's receivers using multiple communications paths consisting of the Internet, radio network or toll-free POTS service. Installation Requirements UL COMPLIANCE To meet UL864/NFPA, ensure the following: IPGSM-4G must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72. IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. IPGSM-4G, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be pro- vided with appropriate standby power. IPGSM-4G must use the 7AH battery (not supplied) to pro- vide 24-hour backup capability. Electrical Specifications Transformer: Primary 120 VAC, 60Hz, 0.5A. Secondary: 18VDC, 50VA. Battery: One 12 V 7.0 AH lead-acid battery (not supplied). Battery charging current: 1 Amp maximum. Battery discharge current: Standby 230mA, Active 950mA. Cabinet Specifications Dimensions: 14.875 H x 12.75 W x 3.0 D (37.8 cm H x 32.4 cm W x 7.6 cm D). Color: Red. Shipping Specifications Weight: 5.3 lbs. (6.94 kg). Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x 34.9 cm W x 23.9 cm D) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 270C/60 - 80°F. Product Line Information IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- cator Panel. Includes red cabinet with Ademco key and lock, wall outlet box, Dialer Capture Module, IGSM Communications Module, antenna & mounting adapter, PowerBoostl power supply, LED display board, transformer, manual, & required screws, cables, etc. Antenna Kits GSM-ANT3DB25KT: 25 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 25 RF cable. GSM-ANT3DB50KT: 50 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 50 RF cable. Antenna External Hardware GSM-ANT3DB: 3db gain external/remote antenna. WA7626-CA: SNA to N Adapter. 7626-5OHC: 50 ft. antenna cable, low loss. 7626-25HC: 25 ft. antenna cable, low loss. NOTE: The GSM-ANT3DB and the WA 7626-CA are both required for installing an external antenna along with the necessary cable needed (7626-50HC: 50 ft. or 7626-25HC: 25 ft.) Other Accessories 7720P: IPGSM-4G hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. BAT-1270: Battery 12 Volts, 7 AH, sealed. Agency Listings and Approvals The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S789. CSFM: 7300-1645:0199. FDNY: COA #6150. Page 2 of 3 DH-60769:C 4/28/14 www.honeywelI.com I This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. 02014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1 Automation and Control Solutions Honeywell I 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpptechserv@honeywell.com www.honeywellpower.com 1 DH-60769:C April Made in the U.S.A. iso ooi kr U.S. Registered Trademark ________________ C-. S I I '1 © 2014 Honeywell International Inc. 1 Page 3ot3 01*111! SYSTEMS I ; ~; DTIT= Photoelectric Smoke Detectors System Sensor's /30 series smoke detectors repres significant advancemen tin conventional detection. The /3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Installation ease. The i3 line redefi nes installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, i1 heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. il detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. Two-wire il detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the j3 protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings & <~> 0 MEA MSFM LISTED APPROVED approved approved 3911 3011446 7272-1209:210 290-01 -E 2093 (j) Smoke Detector Specifications Smoke detector shall he a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2W1-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WJ-B, 4WDB) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA %12\ 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-1 20°F (0°C-49°C); 2W1-B and 4WT-B: 32°F-1 00°F (0°C-37,8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2W1-B and 4WT-B only: 41°F (5°C) Sensitivity 2.51/o/ft nominal Input Terminals 14-22 AWG Mounting LED Mode Green LED 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max, limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12\.5 23mA @ 24V 4W1-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories 2W4MOD2 SENS-RDR 2-wire loop test/ maintenance module RI Sensitivity reader A77-AB2 Removal / replacement tool Retrofit adapter bracket, 6.6 in. (16.76cm) diameter Th SYSTEM 3825 Ohio Avenue. St. Charles, IL 60174 fo, $ Phone: 800-SENSOR2 Fax: 630-377-6495 dohea CUSTOM DOCUMENT ENCLOSURE Modified Mier BW-106R for Bay Alarm 12"Wx 12"H x4'D Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom I Additional customization df ibis cicsue. r assistance in - designing a new model, irLludiilg dotbr andY'or graphics, is available by calling or emailingMier Products,lnc. II - _il ls lot 800-473-0213 I info@mierproducts.com I www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0214 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E, MS-10UD-7, MS-10UD-7C AND MS10-UD-7E Fire alarm control units. The MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module *ANNSEC. Secondary ANN-BUS Module *IPDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 04-23-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120 —ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.ReynoIds2Honeywell.com DESIGN: Model ANN-80 and *ANN80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 7300-1645:0199 Page 1 of 1 I CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 I Email: issa.khouryawadHoneywell.com DESIGN: Models iPGSM-COM, iPGSM-DP, iPGSM-4G and *IGSMCFP4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to I listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with separately listed compatible commercial and residential fire alarm control units. *Model IGSMCFP4G is intended for use with specific I Honeywell Security control units that employ the ECP bus. Refer to listee's installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. iPGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. *Rev 07-01-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t§ LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct JV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division