Loading...
HomeMy WebLinkAbout2841 LOKER AVE E; ; AS160270; Permit12/8/2020 AS160270 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160270 2841 LOKERAV Job Address: Status: ISSUED EAST Permit Type: SPRINK Applied 8/31/2016 Parcel No: 2090831400 Approved: 9/21/2016 Lot #: 0 Reference No.: Issued: 9/21/2016 PC #: Inspector: Project Title: ARGONAUT CLEAN ROOM T.I.: ADD FIRE SPRINKLER PROTECTION IN CLEAN ROOM ADD NEW SPRINKLER DRY PENDENTS IN NEW COLD BOX Applicant: SYMONS FIRE PROTECTION 12155 PAINE PL POWAY, CA 92064 619-588-6364 Owner: HARRIS GORDON L&PHYLLIS K INTER VIVOS TRUST 05-1 2500 6TH AVE #8 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 528 0 528 0 1/1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 8/26/2016 C:\PROGRAN FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 120.0 109.0 8000.0 119.9 625.0 71.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 625.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 375.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 71.5 375.0 2 2.0 - - - - 70.4 - - - 3 4.0 - - - - 69.5 - - - 4 4.0 - - - - 67.5 - - - 5 2.0 - - - - 68.3 6 2.0 - - - - 68.3 - - 7 8.0 - - - - 65.7 - - - 8 23.0 - - - - 59.2 - - 9 23.0 - - - - 59.1 10 23.0 - - - - 57.3 - - - 10A 8.0 - - - - 58.9 11 8.0 - - - - 51.3 - - - 12 8.0 - - - - 46.8 - - - 13 8.0 - - - - 42.1 - - - 14 8.0 - - - - 40.4 - - - 15 8.0 - - - - 37.8 - - - 16 8.0 - - - - 37.1 - - - 17 8.0 - - - - 37.0 - - - 18 8.0 - - - - 32.1 - - 19 8.0 - - - - 31.5 20 8.0 - - - - 29.0 - - - 21 8.0 - - - 28.5 - - - 22 8.0 K= 5.60 17.7 23.5 23 8.0 - - - - 28.8 - - - 24 8.0 K= 5.60 17.8 23.7 25 8.0 - - - - 30.6 - - - 26 8.0 K= 5.60 19.0 24.4 27 8.0 - - - - 27.3 28 8.0 K= 5.60 24.3 27.6 29 8.0 K= 5.60 23.6 27.2 30 8.0 K= 5.60 23.7 27.3 31 8.0 - - - - 26.9 - - - 32 8.0 - - - - 24.3 - - - 33 8.0 K= 5.60 15.3 21.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 ATE:8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HA5583\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 34 8.0 K= 5.60 23.1 26.9 35 8.0 - - - - 23.1 - - - 36 8.0 - - - - 23.1 - - - 37 8.0 K= 5.60 14.5 21.4 38 8.0 - - - - 24.6 - - - 39 8.0 K= 5.60 15.5 22.0 40 8.0 - - - 27.2 - - - 41 8.0 - - - - 26.9 - - 42 8.0 - - - 26.9 - - - 43 8.0 - - - - 24.2 - - - 44 8.0 K= 5.60 15.3 21.9 45 8.0 - - - - 23.5 46 8.0 K= 5.60 14.8 21.5 47 8.0 - - - - 23.5 - - - 48 8.0 K= 5.60 14.8 21.5 49 8.0 - - - - 24.4 - - - 50 8.0 K= 5.60 12.9 20.1 51 8.0 K= 5.60 12.3 19.6 52 8.0 - - - - 27.3 53 8.0 - - - - 26.3 - - - 54 8.0 K= 5.60 19.0 24.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: ,8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 375.0 7.660 PL 200.00 PF 0.2 1 0.0 SRCE 71.5 (N/A) 2.6 150 FTG 2.0 PE -0.9 2 2.0 0.0 70.4 0.0 0.001 TL 202.00 PV Pipe: 2 375.0 9.050 PL 3.00 PF 0.0 2 2.0 0.0 70.4 0.0 1.9 120 FTG 14.0 PE -0.9 3 4.0 0.0 69.5 0.0 0.001 TL 17.00 PV Pipe: 3 FIXED PRESSURE LOSS DEVICE 3 4.0 0.0 69.5 0.0 2.0 psi, 375.0 gpm 4 4.0 0.0 67.5 0.0 Pipe: 4 375.0 9.050 PL 3.00 PF 0.0 4 4.0 0.0 67.5 0.0 1.9 150 FTG 14.0 PE 0.9 5 2.0 0.0 68.3 0.0 0.001 TL 17.00 PV Pipe: 5 375.0 7.660 PL 15.00 PF 0.0 5 2.0 0.0 68.3 0.0 2.6 150 FTG 7.0 PE 0.0 6 2.0 0.0 68.3 0.0 0.001 TL 22.00 PV Pipe: 6 375.0 9.050 PL 3.00 PP 0.0 6 2.0 0.0 68.3 0.0 1.9 150 FTG 7.0 PE -2.6 7 8.0 0.0 65.7 0.0 0.001 TL 10.00 PV Pipe: 7 375.0 8.329 PL 15.00 PP 0.0 7 8.0 0.0 65.7 0.0 2.2 120 FTG 6.0 PE -6.5 8 23.0 0.0 59.2 0.0 0.001 TL 21.00 PV Pipe: 8 375.0 6.357 PL 7.00 PF 0.1 8 23.0 0.0 59.2 0.0 3.8 120 FTG 15.0 PE 0.0 9 23.0 0.0 59.1 0.0 0.005 TL 22.00 PV Pipe: 9 375.0 4.260 PL 42.00 PP 1.8 9 23.0 0.0 59.1 0.0 8.4 120 FTG 14.0 PE 0.0 10 23.0 0.0 57.3 0.0 0.032 TL 56.00 PV Pipe: 9A 375.0 2.635 PL 15.00 PF 4.8 10 23.0 0.0 57.3 0.0 22.1 150 FTG 7.0 PE 6.5 10A 8.0 0.0 58.9 0.0 0.220 TL 22.00 PV Pipe: 10 375.0 2.635 PL 8.00 PP 7.6 10A 8.0 0.0 58.9 0.0 22.1 120 FTG 15.0 PE 0.0 11 8.0 0.0 51.3 0.0 0.332 TL 23.00 PV Pipe: 11 320.2 2.635 PL 5.00 PF 4.5 11 8.0 0.0 51.3 0.0 18.8 120 FTG 13.0 PE 0.0 12 8.0 0.0 46.8 0.0 0.248 TL 18.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE:'8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 270.1 2.635 PL 11.00 PF 4.7 12 8.0 0.0 46.8 0.0 15.9 120 FTG 15.0 PE 0.0 13 8.0 0.0 42.1 0.0 0.181 TL 26.00 PV Pipe: 13 214.7 2.635 PL 2.00 PF 1.8 13 8.0 0.0 42.1 0.0 12.6 120 FTG 13.0 PE 0.0 14 8.0 0.0 40.4 0.0 0.118 TL 15.00 PV Pipe: 14 154.6 2.635 PL 22.00 PF 2.5 14 8.0 0.0 40.4 0.0 9.1 120 FTG 17.0 PE 0.0 15 8.0 0.0 37.8 0.0 0.065 TL 39.00 PV Pipe: 15 102.0 2.635 PL 11.00 PF 0.7 15 8.0 0.0 37.8 0.0 6.0 120 FTG 13.0 PE 0.0 16 8.0 0.0 37.1 0.0 0.030 TL 24.00 PV Pipe: 16 39.5 2.635 PL 7.00 PF 0.1 16 8.0 0.0 37.1 0.0 2.3 120 FTG 13.0 PE 0.0 17 8.0 0.0 37.0 0.0 0.005 TL 20.00 PV Pipe: 17 54.8 1.380 PL 64.00 PF 19.2 11 8.0 0.0 51.3 0.0 11.8 120 FTG 23.0 PE 0.0 18 8.0 0.0 32.1 0.0 0.221 TL 87.00 PV Pipe: 18 50.1 1.380 PL 64.00 PF 15.3 12 8.0 0.0 46.8 0.0 10.7 120 FTG 18.0 PE 0.0 19 8.0 0.0 31.5 0.0 0.187 TL 82.00 PV Pipe: 19 54.8 2.067 PL 5.00 PF 0.6 18 8.0 0.0 32.1 0.0 5.2 120 FTG 13.0 PE 0.0 19 8.0 0.0 31.5 0.0 0.031 TL 18.00 PV Pipe: 20 104.9 2.067 PL 11.00 PF 2.6 19 8.0 0.0 31.5 0.0 10.0 120 FTG 14.0 PE 0.0 20 8.0 0.0 29.0 0.0 0.103 TL 25.00 PV Pipe: 21 55.4 1.380 PL 37.00 PF 11.5 13 8.0 0.0 42.1 0.0 11.9 120 FTG 14.0 PE 0.0 25 8.0 0.0 30.6 0.0 0.226 TL 51.00 PV Pipe: 22 24.4 0.824 PL 4.00 PF 11.6 25 8.0 0.0 30.6 0.0 14.7 120 FTG 15.0 PE 0.0 26 8.0 5.6 19.0 24.4 0.610 TL 19.00 PV Pipe: 23 31.0 1.380 PL 11.00 PF 1.8 25 8.0 0.0 30.6 0.0 6.7 120 FTG 13.0 PE 0.0 23 8.0 0.0 28.8 0.0 0.077 TL 24.00 PV Pipe: 24 23.7 0.824 PL 4.00 PF 10.9 23 8.0 0.0 28.8 0.0 14.2 120 FTG 15.0 PE 0.0 24 8.0 5.6 17.8 23.7 0.575 TL 19.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE:' 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 7.4 1.380 PL 40.00 PF 0.3 23 8.0 0.0 28.8 0.0 1.6 120 FTG 13.0 PE 0.0 21 8.0 0.0 28.5 0.0 0.005 TL 53.00 PV Pipe: 26 23.5 0.824 PL 4.00 PF 10.8 21 8.0 0.0 28.5 0.0 14.2 120 FTG 15.0 PE 0.0 22 8.0 5.6 17.7 23.5 0.570 TL 19.00 PV Pipe: 27 -16.2 1.380 PL 7.00 PF 0.5 21 8.0 0.0 28.5 0.0 3.5 120 FTG 13.0 PE 0.0 20 8.0 0.0 29.0 0.0 0.023 TL 20.00 PV Pipe: 28 88.7 2.067 PL 9.00 PF 1.7 20 8.0 0.0 29.0 0.0 8.5 120 FTG 13.0 PE 0.0 27 8.0 0.0 27.3 0.0 0.075 TL 22.00 PV Pipe: 29 48.4 1.380 PL 4.00 PF 3.0 27 8.0 0.0 27.3 0.0 10.4 120 FTG 13.0 PE 0.0 28 8.0 5.6 24.3 27.6 0.176 TL 17.00 PV Pipe: 30 18.9 1.380 PL 11.00 PF 0.7 28 8.0 5.6 24.3 27.6 4.0 120 FTG 13.0 PE 0.0 29 8.0 5.6 23.6 27.2 0.031 TL 24.00 PV Pipe: 31 -8.3 1.380 PL 13.00 PF 0.2 29 8.0 5.6 23.6 27.2 1.8 120 FTG 13.0 PE 0.0 30 8.0 5.6 23.7 27.3 0.007 TL 26.00 PV Pipe: 32 60.0 1.380 PL 35.00 PF 14.1 14 8.0 0.0 40.4 0.0 12.9 120 FTG 19.0 PE 0.0 53 8.0 0.0 26.3 0.0 0.261 TL 54.00 PV Pipe: 33 1.9 1.380 PL 9.00 PF 0.0 28 8.0 5.6 24.3 27.6 0.4 120 FTG 13.0 PE 0.0 32 8.0 0.0 24.3 0.0 0.000 TL 22.00 PV Pipe: 34 -45.0 1.380 PL 4.00 PF 2.6 32 8.0 0.0 24.3 0.0 9.7 120 FTG 13.0 PE 0.0 31 8.0 0.0 26.9 0.0 0.154 TL 17.00 PV Pipe: 35 40.3 2.067 PL 9.00 PF 0.4 27 8.0 0.0 27.3 0.0 3.9 120 FTG 13.0 PE 0.0 31 8.0 0.0 26.9 0.0 0.017 TL 22.00 PV Pipe: 36 -4.7 2.067 PL 6.00 PF 0.0 31 8.0 0.0 26.9 0.0 0.5 120 FTG 13.0 FE 0.0 41 8.0 0.0 26.9 0.0 0.000 TL 19.00 PV Pipe: 37 21.9 0.824 PL 3.00 PF 9.0 32 8.0 0.0 24.3 0.0 13.2 120 FTG 15.0 PE 0.0 33 8.0 5.6 15.3 21.9 0.499 TL 18.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 'DATE:' 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 38 25.1 1.380 PL 10.00 PF 1.2 32 8.0 0.0 24.3 0.0 5.4 120 FTG 13.0 PE 0.0 34 8.0 5.6 23.1 26.9 0.052 TL 23.00 PV Pipe: 39 0.0 0.824 PL 3.00 PF 0.0 34 8.0 5.6 23.1 26.9 0.0 120 FTG 15.0 PE 0.0 35 8.0 0.0 23.1 0.0 0.000 TL 18.00 PV Pipe: 40 -1.9 1.380 PL 12.00 PF 0.0 34 8.0 5.6 23.1 26.9 0.4 120 FTG 13.0 PE 0.0 36 8.0 0.0 23.1 0.0 0.000 TL 25.00 PV Pipe: 41 21.4 0.824 PL 3.00 PF 8.6 36 8.0 0.0 23.1 0.0 12.9 120 FTG 15.0 PE 0.0 37 8.0 5.6 14.5 21.4 0.476 TL 18.00 PV Pipe: 42 -23.2 1.380 PL 12.00 PF 1.4 36 8.0 0.0 23.1 0.0 5.0 120 FTG 20.0 PE 0.0 38 8.0 0.0 24.6 0.0 0.045 TL 32.00 PV Pipe: 43 22.0 0.824 PL 3.00 PF 9.1 38 8.0 0.0 24.6 0.0 13.3 120 FTG 15.0 PE 0.0 39 8.0 5.6 15.5 22.0 0.504 TL 18.00 PV Pipe: 44 -45.2 1.380 PL 4.00 PF 2.6 38 8.0 0.0 24.6 0.0 9.7 120 FTG 13.0 PE 0.0 40 8.0 0.0 27.2 0.0 0.155 TL 17.00 PV Pipe: 45 7.4 1.380 PL 33.00 PF 0.3 40 8.0 0.0 27.2 0.0 1.6 120 FTG 18.0 PE 0.0 41 8.0 0.0 26.9 0.0 0.005 TL 51.00 PV Pipe: 46 -52.6 1.380 PL 31.00 PF 10.7 40 8.0 0.0 27.2 0.0 11.3 120 FTG 21.0 PE 0.0 15 8.0 0.0 37.8 0.0 0.205 TL 52.00 PV Pipe: 47 2.6 2.067 PL 12.00 PF 0.0 41 8.0 0.0 26.9 0.0 0.3 120 FTG 13.0 PE 0.0 42 8.0 0.0 26.9 0.0 0.000 TL 25.00 PV Pipe: 48 62.5 1.380 PL 29.00 PF 12.7 16 8.0 0.0 37.1 0.0 13.4 120 FTG 16.0 PE 0.0 49 8.0 0.0 24.4 0.0 0.282 TL 45.00 PV Pipe: 49 39.5 1.380 PL 64.00 PF 9.8 17 8.0 0.0 37.0 0.0 8.5 120 FTG 17.0 PE 0.0 52 8.0 0.0 27.3 0.0 0.120 TL 81.00 PV Pipe: 50 42.1 1.380 PL 7.00 PF 2.7 42 8.0 0.0 26.9 0.0 9.0 120 FTG 13.0 PE 0.0 43 8.0 0.0 24.2 0.0 0.136 TL 20.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 'DATE:' 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 51 21.9 0.824 FL 3.00 PF 9.0 43 8.0 0.0 24.2 0.0 13.2 120 FTG 15.0 PE 0.0 44 8.0 5.6 15.3 21.9 0.497 TL 18.00 PV Pipe: 52 20.2 1.380 PL 8.00 PF 0.7 43 8.0 0.0 24.2 0.0 4.3 120 FTG 13.0 PE 0.0 45 8.0 0.0 23.5 0.0 0.035 TL 21.00 PV Pipe: 53 21.5 0.824 PL 3.00 PF 8.7 45 8.0 0.0 23.5 0.0 13.0 120 FTG 15.0 PE 0.0 46 8.0 5.6 14.8 21.5 0.483 TL 18.00 PV Pipe: 54 -1.3 1.380 PL 11.00 PF 0.0 45 8.0 0.0 23.5 0.0 0.3 120 FTG 13.0 PE 0.0 47 8.0 0.0 23.5 0.0 0.000 TL 24.00 PV Pipe: 55 21.5 0.824 PL 3.00 PF 8.7 47 8.0 0.0 23.5 0.0 13.0 120 FTG 15.0 PE 0.0 48 8.0 5.6 14.8 21.5 0.483 TL 18.00 PV Pipe: 56 -22.8 1.380 PL 9.00 PF 1.0 47 8.0 0.0 23.5 0.0 4.9 120 FTG 13.0 PE 0.0 49 8.0 0.0 24.4 0.0 0.044 TL 22.00 PV Pipe: 57 20.1 0.824 PL 5.00 PF 11.5 49 8.0 0.0 24.4 0.0 12.1 120 FTG 22.0 PE 0.0 50 8.0 5.6 12.9 20.1 0.427 TL 27.00 PV Pipe: 58 19.6 0.824 PL 8.00 PF 12.2 49 8.0 0.0 24.4 0.0 11.8 120 FTG 22.0 FE 0.0 51 8.0 5.6 12.3 19.6 0.406 TL 30.00 PV Pipe: 59 -39.5 2.067 PL 8.00 PF 0.4 42 8.0 0.0 26.9 0.0 3.8 120 FTG 13.0 PE 0.0 52 8.0 0.0 27.3 0.0 0.017 TL 21.00 PV Pipe: 60 24.4 0.824 PL 3.00 PF 7.3 53 8.0 0.0 26.3 0.0 14.7 150 FTG 15.0 PE 0.0 54 8.0 5.6 19.0 24.4 0.403 TL 18.00 PV Pipe: 61 35.6 1.380 PL 18.00 PF 2.5 53 8.0 0.0 26.3 0.0 7.6 150 FTG 20.0 PE 0.0 30 8.0 5.6 23.7 27.3 0.066 TL 38.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE:' 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. NOTES (HASS) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.091 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 22.1 ft/sec at pipe 10. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 119.86 psi compared to the minimum required pressure of 20.00 psi. PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 0.824 0.62 1.54 0.62 1.54 1.85 0.31 3.09 3.09 1.54 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 2.635 8.24 16.47 5.49 19.22 9.61 1.37 13.73 13.73 16.47 4.260 13.17 26.33 7.90 28.97 15.80 2.63 26.33 26.33 26.33 6.357 17.60 37.72 11.32 40.23 12.57* 3.77 35.21 35.21 37.72 7.660 43.65 93.53 28.06 99.76 31.18 9.35 87.29 87.29 93.53 8.329 22.16 43.09 16.00 55.40 14.77 4.92 38.16 38.16 43.09 9.050 33.20 64.55 23.98 83.00 22.13 7.38 57.18 57.18 64.55 PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 1.00 1.00 2.067 5.00 10.00 3.00 11.00 6.00 1.00 4.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE:' 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 2.635 6.00 12.00 400 14.00 7.00 1.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 'DATE:' 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. 7; ci) U) 1. C,) 0. E Q. c-ia 0. 0t' 0.Q C 00 (a c) 0 00 00 E CO CO LO (dLf) Ii) • - CnC'J Lr) N ELU U) 110 CflC'J (0 0r- (dl)) (I) )) (1) C(fl I-la) 11) -I->lCl) ((JO 0. 0) -H @12 -H 0. CO-H -I-) 00) H CU) -H-H OEId H Q "0 Cl) 0 0. to CI) > (I) H 00. CC. 4J -,I U) 00 I-I .0 0 C) HO) -H • -HID 0' HO) -H ID ' CO U) 0)01 C' • 00) (3'. >, l)H Ur- 1lH N 0.In0 C. I II N (D 0 0 0 0 0 0 (N 0' W X) 0 0' rH 03 10 (N H 0DC)U) 0U)U)U)(3U) -Q.u)•H--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 8/26/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\16-323.SDF JOB TITLE: ARGONAUT CLEAN ROOM - 16 HEAD CALC. WATER SUPPLY CURVE 120*0\\\\\\\\\\\\\\\ I \\\\\\\\\\\\\\\\ I \\\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\ 110+ 109.0 Psi @ 8000 gpm-> * Flow Test Point 100+ 90+ P80+ R I E S IX S 70+ U R E 60+ P I S l• I 50+ 40+ 30+ 20+ LEGEND I! X = Required Water Supply 71.46 Psi @ 625.0 gpm 10+ I 0 = Available Water Supply 119.90 Psi 8 625.0 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) tJJCJ7 Fire Suppression & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Email: techserv@tycofp.com Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The Tyco® Series RFll Quick Response (3-mm bulb) and Standard Response (5-mm bulb), 5.6 K-Factor, "Royal Flush II" Concealed Pendent Sprin- klers are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFlI Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Page 1 of 6 OCTOBER 2009 TFPI8I TFPI8I Page 2 of 6 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. 1/2' NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB ROLL FORMED THREADS - COMPRESSION SCREW GUIDE PINS (2) DEFLECTOR DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO 14 RETAINER SUPPORT CUP WITH THREAD UNTIL MOUNTING 0 DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING '- I SPRING SOLDER J . COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, LPCB Approved (Ref. No. 094a/10), VdS Approved (Cer- tificate No. G 4090007), and NYC Approved (MEA 353-01-E) as Quick Response. 1Y3531 (3-mm Bulb) is FM Ap- proved as Standard Response. Factory Mutual does not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F/68°C Sprinkler with 1 39°F/59°C Plate 200°F/93°C Sprinkler with 1 65°F/74°C Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/barl'2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ...................Bronze Support Cup... Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ Teflont Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel tDuPont Registered Trademark Design Criteria The Tyco® Series RFlI Concealed Pen- dent Sprinklers are intended for fire protection systems designed in ac- cordance with the standard instal- lation rules recognized by the appli- cable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Sup- pression & Building Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFll Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler op- eration in a fire situation. FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2k (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION TmdTT /- CLEARANCE HOLE TFPI8I Page 3 of 6 Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector—supported by the Guide Pins—then drops down to its operational position. The glass Bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. I I I V MANUFACTURER DEFLECTOR COVER PLATE PRESET GAP IN DROPPED RETAINER 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE DIAMETER DIMENSION A 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS 3/16to11/16 (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B FIGURE 4 DISPOSABLE PROTECTIVE CAP TFPISI Page 4 of 6 Installation The Tyco® Series RFII must be in- stalled in accordance with the follow- ing instructions. A(I)IfP Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1550F/680C and 3/32 inch (2,4 mm) for the 200°F/930C temperature ratings. Obtain a 1/2 inch NPT sprinkler joint by applying a minimum to maximum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can dis- tort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFll Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate/Re- tainer Assembly, remove and discard the Protective Cap. Verify that the De- flector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, pro- ceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. Care and Maintenance The Tyco® Series RFll must be maintained and serviced in accordance with the following instructions. Before closing a fire protection sys- tem main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and no- tify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Replace sprinklers that: are leaking or exhibiting visible signs of corrosion. were modified or over-heated. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint facto- ry-painted Cover Plates. If necessary, replace them with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. Responsibility lies with sprinkler own- ers for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the ap- plicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL BEVEL AS SHOWN COVER PLATE RETAINER ASSEMBLY CLEAN ROOM LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) TFPI8I Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBR No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of prod- ucts or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incom- plete information supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: (SIN), (temperature rating from below) Series RFll Concealed Pendent Sprinkler, P/N (specify). 155FI68°C 2OOF/93°C TY3531 51-792-1-155 51-792-1-200 1Y3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFll Concealed Cover Plate with (finish), P/N (specify). 139F/59°C(a) 165°F/74°C(b) Brass..........56-792-1-135 56-792-1-165 Chrome........56-792-9-135 56-792-9-165 Signal White (RAL 9003).... 56-792-4-135 56-792-4-165 Grey White (RAL 9002).... 56-792-0-135 56-792-0-165 Pure White (c) (RAL 9010).... 56-792-3-135 56-792-3-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F/68°C sprinklers. For use with 200°F/93°C sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. tqco Ffre Protection Products Worldwide I Contacts www.tyco-fire.com Series DS-1 - 56 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprin- kler drops from unheated portions of buildings) sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g., sprin- kler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or hor- izontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) sprinklers are used on systems that are seasonably drained to avoid freezing (e.g., vacation resort areas) NOTICE Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved TY3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-E LPCB Approved Reference No. 094a/11 CE Certified Certificate of Conformity No. 0832- CPD-201 5 (Refer to Tables A and B for details.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1 inch NPT ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi112 (80,6 1pm/barl'2) Temperature Ratings Refer to Tables A and B. Finishes Sprinkler: Refer to Table D. Escutcheon: Refer to Table D. JANUARY 2015 - Physical Characteristics Inlet.........................Copper Plug ........................Copper Yoke ..................Stainless Steel Casing ........Galvanized Carbon Steel Insert .......................Bronze Bulb Seat ..............Stainless Steel Bulb (5 mm dia.) ................Glass Compression Screw............Bronze Deflector.....................Bronze Frame .......................Bronze Guide Tube.............Stainless Steel Water Tube.............Stainless Steel Spring.................Stainless Steel Sealing Assembly.......Beryllium Nickel w/TEFLON Escutcheon .............Carbon Steel TFP500 TFP500 Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED V P0 * L PENDENT (TY3255) STANDARD 135°F (57°C) Orange 1,2,3,4,5,6 1 ' 2 4 5 6 155°F (68°C) Red 175-F (79-C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2, 3, 6 1, 2, 6 RECESSED 135°F (57°C) Orange 1,2,3,5 1,2,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1,2 360°F (182°C) Mauve N/A DEEP 135°F (57°C) Orange 1, 2,3,4,5 1,2,4, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve WITHOUT 135°F(57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1,2, 3 1,2 UPRIGHT (TY3155) WITHOUT _ 135°F (57°C) Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F(182°C) Mau,e 1,2,3 1,2 Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-E Approved by VdS * Frame and deflector only N/A - Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5,6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER ESCUTCHEON TEMPERATURE BULB SPRINKLER FINISH NATURAL BRASS CHROME PLATED POLYESTER' TYPE TYPE RATING COLOR CODE 135°F (57°C) Orange 155-F (68-C) Red 175°F (79°C) Yellow STANDARD 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F(68°C) Red HSW* (TY3355) DEEP 175°F (79°C) Yellow 3*** 4, 5 1**, 2**, 4 5 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow WITHOUT 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 2°, 5 1°°, 2°° Notes: Listed by Underwriters Laboratories. Inc. (UL), maximum order length 0148 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-E * Horizontal sidewall with top of deflector-to-ceiling distance of 410 12 inches (100 to 300 mm) Light and ordinary hazard occupancies only Light hazard occupancies only Frame and deflector only TABLE B SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET SEALING ASSEMBLY YOKE H -.-.... SPRING INLET BAND WATER II ii TUBE CASING GUIDE - INSERT TUBE BULB FRAME —*'/ SEAT .- 5 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY WRENCH RECESS WRENCH I FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 WRENCH TFP500 Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS I I I FACOF[_I CEILING 2-3/16' ± 1/8 3' DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" h(88,9 mm) - (12,7 to 1168,4 mm) I IN 1/4" (6,4 mm) 2-1/2" DIA. INCREMENTS I (635 mm) FACE CEILING 4-1/4" ±1/8" (108,0 ± 3,2 mm) FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 5' to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5' to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING - \ SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT (TY3155) WITHOUT ESCUTCHEON TFP500 Page 5 of 10 ORDER LENGTHS: 2-3/4 to 48° (69,9 to 1219,2 mm) IN 1/4(6,4 mm) INCREMENTS 2-3/8' ± 1/8" (60,3±3,2 mm) FACE OF FACE OF SPRINKLER MOUNTING FITTING SURFACE mAi _ Ti4 3"DIA. (76,2 mm) 3.5° 1-3/4° DIA. SPRINKLER FITTING (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2° to 45-3/4" (12,7 to 1162,1 mm) IN 1/4(6,4 mm) INCREMENTS 4-1/4" ± 1/8" L 2-1/2" DIA. FACE OF (108,0 ± 3,2 mm) FACE OF (63,5 mm) MOUNTING SPRINKLER FITTING SURFACE FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2' to 48' (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 2-1/4' (57,2 mm) FACE OF 1 - DEFLECTOR To - SPRINKLER I MOUNTING FITTING SURFACE EIIIIIIIiIIIIIIIIIIIIIIIIII1I 3.5*I 5/16" / SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Ref. Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow- ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble listing or approval agency (e.g., UL Listing is based on NFPA 13 require- ments). For more information on LPCB Approval, contact Tyco Fire Suppres- sion & Building Products at the follow- ing office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 inch NPT Series DS-1 Dry-type Sprinklers in the 1 inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 3-1/2° DIA. T (88,9 mm) - / 3.5° CENTERLINE 5/16° OF WATERWAY (7,9 mm) TFP500 Page 6 of 10 Temperatures for Heated Area(1) Ambient Temperature 4°F 50°F 60°F Exposed to (4 C) (10-C) (16-C) Discharge End of Sprinkler Minimum Exposed Barrel Length(2), Inches (mm) 40°F (4°C) 0 0 0 30°F (-1°C) 0 0 0 20°F 40 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 30 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS You can also install Series DS-1 Dry- type Sprinklers in the 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1 inch NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 inch reducing tee when locating Series DS-1 Dry-type Sprinklers directly below the branchline; otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprin- klers and the branchline. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Tyco Fire Protection Products (TFPP) Technical Services. Failure to use the appropriate fitting may result in one of the following: failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Pro- tection Association for dry pipe sprin- kler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when con- necting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprin- klers must be sealed. Due to tempera- ture differences between two areas, the potential for the formation of conden- sation in the sprinkler and subsequent ice build-up is increased. If this con- densation is not controlled, ice build-up can occur that might damage the dry- type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP500 Page 7 of 10 FACE OF - SPRINKLER -a - FITTING Ir EXPOSURE LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 11 EXPOSURE LENGTH T- RUN OUTLET PLUGGED TO DRY SPRINKLER FI1TING SYSTEM (SEE DESIGN CRITERIA SECTION) DSB-2 FOR FREEZER INTENDED STRUCTURES zz —c ICJ FIGURE 12 SPRINKLER FITTING UNHEATED AREA TO WET SIDE SYSTEM OUTLET PLUGGED DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) 7 -4-- ]cj FIGURE 13 SPRINKLER FITTING HEATED AREA STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE t1J DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER 1-3/4' DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE D\ STRUCTURE SB-2 BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 8 of 10 Installation TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers must be installed in accordance with this section. General Instructions Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Notes: Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendicu- lar to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 1. With a non-hardening pipe- thread sealant such as TEFLON applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Ref. Figure 1) the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 2) Apply the wrench recess of the W-Type 7 Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutch- eon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response, Standard Cover- age Dry-type Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP500 Page 9 of 10 12 PIN* 60 - XXX I - X - XXX I SIN SPRINKLER ESCUTCHEON FINISH FINISH(1) 96 Pendent with TY3255 CHROME SIGNAL WHITE Standard Escutcheon (1" NPT) (Figure 3) 0 PLATED (RAL9003) POLYESTER 93 Pendent with TY3255 Deep Escutcheon (1" NPT) (Figure 5) NATURAL SIGNAL WHITE - 97 Pendent with 1 TY3255 BRASS (RAL9003) POLYESTER Recessed Escutcheon (1° NPT) (Figure 4) - 92 Pendent without TY3255 2 NATURAL BRASS Escutcheon (1 NPT) (Figure 6) BRASS PLATED Sidewall with TY3355 94 Standard Escutcheon (1" NPT) (Figure 8) 53 Sidewall with TY3355 - Deep Escutcheon (1" NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon (1' NPT) (Figure 10) 98 Upright without TY3155 I I I Escutcheon (1° NPT) I (Figure 7) Notes: Escutcheon Finish applies to sprinklers provided with escutcheons. 360"F (182"C) temperature rating applies to non-recessed sprinkler assemblies. Dry-type Sprinklers are furnished based upon "Order Length" as mea- sured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. * Use Prefix "I" for ISO 7-R1 connection (e.g., -60-961-1-180). SIGNAL WHITE 4 (RAL9003) POLYESTER CHROME PLATED TEMPERATURE RATING(2) 0 135°F (57°C) 1 155°F(68°C) 2 175-F (79-C) 3 200°F (93°C) 4 286-F (141-C) 5 360-F (182-C) SIGNAL WHITE (RAL9003) POLYESTER CHROME PLATED ORDER LENGTH(3) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" TABLED SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Dry-type Sprinklers When ordering Series DS-1 5.6K Pendent, Upright, and Horizontal Side- wall, Standard Response, Standard Coverage Dry-type Sprinklers, specify the following information: SIN: TY3255 - Pendent 1V3155 - Upright TY3355 - Horizontal Sidewall Order Length: Dry-type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections: 1 Inch NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Tyco Sales Representative.) Temperature Rating Sprinkler Finish Escutcheon Type and Finish, as applicable P/N from Table D Part numbers are for 1 inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhe- sive (a sufficient quantity for installing one boot).