Loading...
HomeMy WebLinkAbout2858 LOKER AVE E; ; FPC2018-0400; Permit(pty of PERMIT REPORT Carl sbad Print Date: 12/08/2020 Permit No: FPC2018-0400 Job Address: 2858 LOKER AVE E, CARLSBAD, CA 92010-6673 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090832100 Track #: Applied: 12/10/2018 Valuation: $85,000.00 Lot #: Issued: 12/20/2018 Occupancy Group: Project #: Finaled Close Out: 12/08/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: , Inspector: Plan Check #: Final Inspection: Project Title: Description: OPIUM RX -MONITORING OF NEW EMERGENCY GENERATOR Applicant: FPContractor: JMG SECURITY SYSTEMS JMG SECURITY SYSTEMS TREVOR ASHFORD 17150 NEWHOPE ST, # 109 17150 NEWHOPE ST, # 109 FOUNTAIN VALLEY, CA 92708-4273 FOUNTAIN VALLEY, CA 92708-4250 (714) 545-8862 (714) 943-6156 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-7602-8561 f I www.carlsbadca.gov HIGHLIGHTED SET UL & FM Certificates of Compliance Cut Sheets and CSFM listings 1 OPTUM RX 2858 Loker Avenue, Carlsbad, CA 92010 Revision #3: Tenant Improvements Installation Company: r;J0 JGMSYSTEMS SECURITY Our service is your security. 17150 Newhope Street Fountain Valley, CA 92708 - (714) 545-8882 FPC20I8-0400 2858 LOKER AVE E OPTUM RX - MONITORING OF NEW EMERGENCY GENERATOR 2090832100 12/10/2018 FPC20I8-0400 tJL LLC CERTIFICATE OF COMPLIANCE COVER PAGE .• - Applicant Subscriber No: 257057-001 Service Center Number: 1 Service Contract No: - • ACTIVE LISTINGS • CCN File No. Vol. No UUFX S8126 1 b. CRZM BP10307 1 Listed Service From: LAKE FOREST, CA Alarm Service ComDanv: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 4 01-APR-15 D9412GV3 Control Panel t±: The D9412GV3 Control Panel delivers a powerfulnew solution for intrusion, access control, and fire alarm system applications. The control panel includes a communicator that sends events to selected public switched telephone network (PSTN), IP network, or general packet radio service (GPRS) destinations through four programmable route groups. The control panel provides up to 246 individually identified points. Each point: Accommodates normally-open (NO) and normally-closed (NC) devices with end-of-line (EOL) resistor supervision Is programmable for fire, fire supervisory, or intrusion applications. With the D9412GV3 you can: Monitor alarm points for intruder or fire alarms while operating user keypads and other outputs Program all system functions on-site through a D5200 Programmer; locally or remotely through Remote Programming Software (RPS). Add up to eight doors of access control using the optional D9210BLC Access Control Interface Module. Functions Programmable Outputs 2'A alarm power at 12 VDC 1.4 A auxiliary power at 12 VDC Four alarm-output patterns . Programmable bell test Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three Conettix IP based communication options provide high-speed, secure alarm transport and control through connection of up to two wired (DX4020) and/or wireless (ITS-DX4020-G) networkinterfaces Eight programmable areas with perimeter and interior partitioning ' 246 points with flexible configuration options to meet multiple installation requirements Commercial Wireless allows up to 238 RF points Your choice of vacuum fluorescent or ATM style user interface keypads System Response High-performance micro-controller provides industry-leading system response 31 custom point indexes, including fire supervisory Selectable point response time Cross point capability Fire alarm verification Fire inspector's local test Watch mode Scheduled events (keds) arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access User Interface Supervision of up to eight keypads (up to 32 unsupervised keypads can be used) Custom keypad text is fully programmable, including remote programmingt Full function command menu including custom functions Authority by area and 16-character name for each user 14 custom authority levels control user's authority to change, add, or delete passcodes or access control credentials; to disarm or bypass points; and to start system tests www.boschsecurity.com 21 D9412GV3 Control Panel : Area Configurations... . .. . .. Door-Activated Custom Function- Area programming offers a wide selection of different A custom function activates when user credentials are system configurations. Each area is assigned an account presented to a D9210B door controller's reader. The number to define annunciation, control, and reporting custom function behaves as though the user performed a functions. Multiple areas can be linked to a shared area function at the keypad associated with the door controller. Which is automatically controlled (hallway or lobby). Area Passcodes arming can be conditional on other areas (master or . User passcodes contain three to six digits. Assign each user. associate). Any area can be configured for perimeter and . one of 14 customized authority levels in each area. Restrict interior arming, not requiring a separate area for this passcodes to operate only during certain times. function.. . The Two Man Rule and. Early Ambushoptions require two . Two Man Rule . . passcodes, providing additional security in financial Two Man Rule provides added security by requiring: establishments such as banks. Two people present at opening:,. Communications . . . . Two unique passcodes on the same keypad to disarm an area The D9412GV3 Control Panel priofitizes and sends reports Without the second passcode, the system denies entry. in Contact ID or Modem lila2 communications formats to Early Ambush four route groups. Each group has .a programmable primary . Early Ambush requires two passcode entries on the same and backup destination. .. keypad. Enter the same passcode twice or have two unique The D9412GV3 provides flexible communications for most passcodes, depending on the configuration. The first entry . . central stations with reporting capabilities such as: disarms the area and the second entry stops a timer . . . Individual point numbers programmed to send a duress event. If the second entry Opening or closing reports by user and area number . does not occur within the programmed time, the system Remote programming attempts generates a duress event. Early Ambush allows users to Diagnostic reports The inspect the premises and use the system to confirm that the D9412GV3 uses the DX4020 Ethernet Network area is safe to enter, providing added security. Interface Module and/or the ITS-DX4020-G GPRS/GSM Communicator to communicate with the Conettix D6600 Easy Exit Control and D6100i Communications Receiver/Gateways. Using The D9412GV3 Control Panel changes from one armed state Conettix IP communication offers a secure path that to another armed state without disarming. For example, if includes anti-replay/anti-substitution features and provides you change the state from Master Arm to Perimeter Arm, the enhanced security with encryption. Both the DX4020 and control panel complies and reports the change. Easy Exit ITS-DX4020-G can be used for remote programming. Control reduces the number of keystrokes, simplifying Security and Fire Detection system operation. The D9412GV3 Control Panel provides eight on-board Programmable Passcode-controlled Menu List points, and up to 238 additional off-board points The system prompts users to enter a passcode prior to (depending on model and expansion interfaces). You can viewing the keypad menu. The keypad display shows the program individual points to monitor all types of burglar user the menu options allowed according to the user's alarms, fire alarms, and supervision devices. authority level. Passcode-controlled menus provide users Commercial Wireless only with the options and information pertinent to them, simplifying system operation. The Commercial Wireless platform, powered by lnovonics wireless mesh network technology, ensures superior range, Passcode Follows Scope reliability, and scalability for commercial applications. Use Passcode Follows Scope to restrict passcode arming Using a wide range of transmitters and repeaters, this and disarming to the keypad's immediate local area, even if proven technology provides flexibility and performance to the keypad can report events from other areas. Passcode meet the most stringent requirements. This exclusive Follows Scope simplifies the arming and disarming protocol is available only on Commercial Wireless products. procedure without limiting any other keypad capabilities. Invisible Walk Test A menu item allows the user to test invisible 24-hour points within the scope of the keypad without sending a report to the central station. a1I1 Control IPanel IEJ The Commercial Wireless platform sends redundant When resetting alarms or arming or disarming a system, the information on several multi-frequency channels within the user is identified by name and number. FCC Part 15 900 MHz band, providing superior range and ROM Updates reliability. In comparison, systems that use a single An on-site flash update key provides for easy feature frequency technology can only send information on one enhancements without replacing ROM chips. narrow band channel. Any interference within the band can cause missed signals. With wireless registration, it is easy to add this technology to any application. Event Log The event log stores up to 1,000 local and transmitted events. The event log includes time, date, event, area, point, •and user number. View the event log from a keypad or use RPS to remotely retrieve event information. RPS operators can retrieve events periodically using one phone call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. Access Control The D9412GV3 provides custom door strike, point shunt and auto disarming response by area. There are 14 panel-wide access levels with both manual and scheduled control. Store, view, or print access events such as: Access granted No entry Request-to-enter Request-to-exit Scheduled Events (Skeds) The internal clock and calendar start individually scheduled events (skeds). Skeds perform functions such as arm or disarm, relay control, or point bypassing. The D9412GV3 Control Panel offers: 40 scheduled events with up to 25 different functions Eight opening windows and eight closing windows Eight user windows Day-of-week, date-of-month, or holiday only schedules Four holiday schedules of 366 days each (leap year) Fire Test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points. Programming, Diagnostics and Controls Installers can program on-site with a D5200 Programmer, Direct-connect, or remotely through RPS. A programmable system passcode prevents unauthorized remote programming. D9412GV3 Control Panels accommodate up to four separate destinations for primary, alternate, and backup receivers for automatic test reports. Certifications and Approvals The D9412GV3 has been designed to comply with the following: USA •UL AMCX: Central Station Alarm Units (UL1610, UL1635), AMTB: Control Panels, SIA False Alarm Reduction (ANSI/SIACP-01-2000), AOTX: Local Alarm Units (UL464, UL609), APAW: Police Station Alarm Units UL365, UL464), APOU: Proprietary Alarm Units(UL1076), NBSX: Household Burglar Alarm System Units (UL1023), UOJZ: Control Units, System (UL864, 9th edition), UTOU: Control Units and Accessories - Household System Type (UL985) FCC Installation/Configuration Notes Compatible Products Keypads D1260 Series Keypads (D1260, 01260W, D1260R, D1260BLK, D1260B) D720 Series Keypads (0720, D720W, D720R, D720B) D1255 Series Keypads (D1255, D1255W, 01255B, D1255RB) D1256RB Fire Keypads D1257R8 Remote Fire Alarm Annunciators D279A Independent Zone Control Detectors 0278S Four-wire Addressable Detector Base, 12VDC D285/TH Photoelectric Smoke Detector Heads D298S Addressable Detector Base, 24 VDC 07050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads F220-136PM/S Addressable Detector Bases with POPITs MX775i Addressable PIR Detector MX794i Long Range Multiplex PIR Detector MX934i Addressable PIR Detector MX938i Addressable PIR Detector ZX776Z PIR Detector www.boschsecurity.com 41 D9412GV3 Control Panel ZX794Z Long Range PIR Detector Reader ARD-11110 iCSS Mullion Reade ZX835 TriTech Microwave! PIR Detector ARD-1140 1CLASS Switchplate Reader ZX935Z PIR Detector ARD-RK40-09 iCLASS PIN Reader ZX938Z PIR Detector ARD-VSMART iCLASS Reader ZX970 PIR/Microwave Detector D8223 Prox Pro Reader Bosch conventional detectors, including Blue Line, D8224 Mullion Reader, seismic, PIR,lrilech PIR Microwave, photoelectric, D8224-SP Switch Plate Reader heat, and smoke. . D8225 Mini Mullion Reader Enclosures D8103 Universal Enclosure D8301W Low-profile Proximity Readers D8108A Attack-resistant Enclosure Commercial Wireless ISW-08125CW Commercial Wireless Interface D8109 Fire Enclosure Products ISW-EN7280 Serial Receiver Magnetic Contacts Bosch magnetic contacts include recessed, ISW-EN4200 Serial Receiver terminal connection, miniature, ovemead door, ISW-EN4204R LED Receiver and surface mount. lSW-EN4216R LCD Receiver Modules • Conettix ITS-0X4020-G GPRS/GSM Integrated lSW-EN4016SK Survey Receiver Communicator ' IS W-EN 5040-1 High-power Repeater Conettix 0X4020 Network Interface Module ISW-EN1210 Universal Transmitter (Single-input) Conettix 0X4010V2 USB/Serial Interface Module - ISW-EN1210E0L Universal TransmitteL r with -. ED • Conettix C900V2 Dialer Capture Module Resistor D113 Battery Lead Supervision Module ISW-EN121OSK Survey Transmitter D125B Dual Class B Initiating Module ISW-EN12 low Door-Window Transmitter with D127 Reversing Relay Module Reed Switch D129 Class A Initiating Module ISW-EN1215E0L Universal Transmitter with Wall D130 Auxiliary Relay Module Tamper and EOL Resistor D185 Reverse Polarity Signaling Modjle lSW-ENl2l5WEOL Door-Window Transmitter with Wall Tamper, Reed Switch, and EOL Resistor D192G Notification Appliance Circuit Module ISW-EN1223D Water-resistant Pendant D928 Phone Line Switcher Transmitter (Double-button) D5060 MUX Programmer ISW-EN12235 Water-resistant Pendant D8125 POPEX Point Expander Transmitter (Single-button) D8128D OctoPOPIT Eight-point Expander ISW-EN12235K Survey Pendant Transmitter D8125MUX Point Expander ISW-EN1233D Necklace Pendant Transmitter D81251NV Wireless Interface Module (Double-button) D8129 Octo-relay Module ISW-EN1233S Necklace Pendant Transmitter (Single-button) D8130 Door Release Module ISW-EN1235D Beltclip Pendant Transmitter 69127 Series POPIT Modules (Double-button) D9131A Parallel Printer Interface Module ISW-EN12355 Beltclip Pendant Transmitter D9210BLC Access Control Interface Module (Single-button) D57432 Eight-input Remote Module ISW-EN1235DF Fixed-location Transmitter DS7457i Series Single-zone Multiplex Input (Double-button) Modules ISW-EN 1235SF Fixed-location Transmitter DS7460i Two-input Module (Double-button) DS7461i Single-input Multiplex Module ISW-EN 1242 Smoke Detector-Transmitter DS7465i Input and Output Module ISW-EN 1247 Glass-break Sensor Transmitter ICP-SDI-9114 SDI Splitter ISW-EN1249 Billtrap Transmitter lSW-EN 1260 PIR Motion Sensor Transmitter Programming D5200 Series Programmers (Commercial and High-end Domestic Applications) RPS or RPS-LITE Remote Programming Software ISW-EN1261HT PIR Motion Sensor Transmitter (High-traffic Areas) ,1PLeiYIControlI Panel TuII:. . ISW-EN 1262 PIR Motion Sensor Transmitter Parallel Printers: 3 (Residential and Low-traffic Commercial . Points: 246 (8 on-board, up to 238 off-board) Applications) - ISW-EN1265 PIR Motion Sensor Transmitter Programmable Relay Outputs: 131 (Ceiling-mount Applications) RE Points: 238 SKEDs: 64 - •- . .-. . ...,. ., Power Requirements . . Parts Included . :. . .. . . . . Current Draw (Maximum): 300 mA The D9412GV3 includes the following parts: Output (Alarm): 2Aat12VDC Quant. Component Output (Auxiliary, Continuous 1.4 A at 12 VDC nominal 1 D9412GV3 Board . . . Power, add Switched Auxiliary combined): . . 1 Mounting Skirt . Voltage (Operating): 12 VDC nominal 1 Faceplate with D9412GV3 Label . - .. ..... Voltage (AC): . 16.5 VAC 40 VA plug-in transformer The available kits come with the parts indicated in the following table: (01640) Kits .Trademarks . Components -A -B . -C Trademark names are used throughout this document. In D9412GV3 Board 1 1 1 most cases these designations are claimed as trademarks D101F Lock and Key Set 1 or registered trademarks in one or more countries by their D122 Dual Battery Harness 1 . respective owners. Rather than placing a trademark symbol 0161 Dual Modular Phone Cord 2 in every occurrence of a trademark name, Bosch Security . Systems, Inc. uses the names only in an editorial fashion D928 Dual Phone Line Switcher 1 and to the benefit of the trademark owner with no intention D1640 Transformer 1 1 of infringing the trademark. D8103 Enclosure 1 D8108A Attack-resistant Enclosure 1 Inovonics is a trademark of Inovonics Wireless Corporation. D8109 Fire Enclosure 1 Ordering Information Technical Specifications - - - D9412GV3 D9412GV3 -. Includes one printed circuit board (PCB). Communications D9412GV3-A D9412GV3-A SDI Bus A (+): 9 VDC Contains one PCB, one transformer, and one 4572m (150O0 ft) attack-resistant enclosure. SDI Bus B (-): 9 VDC D94120313 D94120313 41_111572 m (15,000 ft) Contains one PCB, one dual battery harness, - ............- Telephone ...ne telephone line two telephone cords, one telephone line Connection: • D928 Dual Phone Line Module required for two switcher, one transformer, and one fire enclo- telephonelines tf.................................................................-. D9412GV3-C D9412GV3-C Environmental Considerations Contains one PCB, one lock and key set, one Relative Humidity: 5% to 93% at +30°C (+860F), transformer, and one universal enclosure. non-condensing Temperature (Operating): 0°C to +50°C (+32°F to + 122°F) Number of... Areas: 8 Card Readers (Doors): 8 Credentials (Tokens): 996 Custom Functions: 16 Events: Up to 1000 Passcode Users: 249, plus 1 service passcode www.boschsecurity.com D9412GV3 Control Panel Ordering Information Ordering Information - - Accessories - D1640 Transformer D1640 ICP•SDI-9114SD1 Splitter IcP-SDI•9114 System transformer rated at 16.5 VAC, 40 VA. Provides the ability to set up two independent D8004 Transformer Enclosure D8004 SDI buses from a single SDI connection on the For applications such as fire alarm that might control panel. require a transformer enclosure. D928 Dual Phone Line Swjtcher D928 D8103 Enclosure D8103 Allows the control panel to operate over and - Grey steel enclosure measuring 41 cm x41 cm supervise two separate phone lines. Only one x 9 c (16 in. x 16 in. x 3.5 in.). D162 phone cord is supplied. Two additional D161 or D162 phon . e cords are required. - - --------------- --------- -------------------------------------------------- D8108A Attack Resistant Enclosure D8108A - -- --- --• Grey steel enclosure measuring41cmx41cm DllO Tamper Switch D110 19 cm (16 in xl6 in. x3.5 in.) UL Listed. Screw-on tamper switch that fits all • Includes lock and key set. Requires the D2402 enclosures Shipped in packages of two Mounting Plate ICP-EZTS Dual Tamper Switch 1CPEZTS 138109 Fire Enclosure D8109 - Combination tamperswitch with awire loopfor - Red steel enclosure measuring 40.6 cm - additional tamper outputs. * - - - 40.6 cmx 8.9cm (16 in. x 16 in. x 3.5 in). D101 Lock and Key Set D101 UL Listed. Includes a lock andkeyset Standard lock set with one key supplied. Uses D9002-5 Mounting Skirt D9002-5 the D102 (#1358) replacement key. - Mounts inside D8103, 08108A, and D8109 D122 Dual Battery Harness 1)122 enclosures Can accept up to six standard Harness With circuit breaker. Connects two - - - 7.62cmx12.7crn(3in.x5in.)cards. batteries to a compatible control panel Software Options 1)1221 Dual Battery Harness with Long D122L RPS Kit (LPT) D5500CLPT Leads Account management and control panel- Color-coded harness with circuit breaker and programming software with LPI connection. leads measuring 89 cm (35 in.). Connects 12V RPS Kit (UsB) D5500C-USB batteries to compatible control panels. Account management and control panel- D126 Standby Battery (12 V, 7 Ah) D126 programming software with USB connection. Sealed lead-acid standby and auxiliary rechargeable power supply. D 1218 Battery (12 V, 18 Ah) D1218 A 12 Vsealed lead-acid battery forstandbyand auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors D1224 Battery (12V,26.28Ah) ° D1224 A 12 Vsealed lead-acid battery for standby and auxiliary power with two bolt-fastened - terminals. Includes hardware for attaching battery leads or spade connectors. D1238 Battery (12 V.38 Ah) D1238 A 12 Vsealed lead-acid battery for standby and auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors. D137 Mounting Bracket D137 Used to mount accessory modules in 08103, D8108A, and 08109 enclosures. D138 Mounting Bracket, Right Angle D138 Used to mount accessory modules in D8103, D8108A, and D8109 enclosures. Americas, Europe, Middle East, Africa, AslaPacific, Represented by Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems 130 Perinton Parkway • P.O. Box 80002 1 11 Blxhan Street 21 Fairport, New York, 14450, USA 5600 JS Eindhoven, The Netherlands Singapore 573943 Phone; -1800 289 0096 Phone: 31402577 284 Phone: *65 6571 2600 Fax +1585 223 9180 - Fax +3140 2577 330 • Fu,: +65 6571 2698 - secunty.sales@us.bosch.com emeosecuritysystems@bosch.com apr.èecurItysystemsbosch.cum www.boschsecurlty.as www.boschsecurity.com www.boschsecurity.com © Bosch Security Systems Inc. 20101 Data subject to change without notice T6695631627 i Cur: en-US, Vi, 27 Apr 2010 Table 3 UL. Listed Components Compatible with the D9412GV3 and D7412GV3 Control Panels 0 2! E aER j E .2 a be 0 ao wQ C .0 .2E C .9 - o o U) 8 !° o •• LL 2-8 U) U) .0 . - L3 t2 U U.S2 E o o O. -be -W . o 0 00 0 o2 U)_ o2 Coo LU _ Minimum Hours of Standby Battery 4 -- 24 +4min 4 4 4 24 + 5 min alarm alarm D8103/08109 Enclosure opt Opt Opt Opt No Opt. No Opt. Opt No No Opt No D8108A Enclosure Opt. Opt. Opt. Opt I Req. Opt.. Req. Opt Opt. Req., Req. Opt Opt. D125B Class B, Style A Powered Loop Opt. Opt. Opt. Opt Opt. Opt Opt. . Opt Opt opt.. Opt. Opt. Opt. Interface* D129 Class A, Style D Initiating Opt. Opt. Opt. Opt. Opt. Opt Opt. Opt Opt Opt. Opt. Opt. Opt. Module" D928 Dual Phone Line Module Opt. Opt. Opt. Opt. Opt. Opt Required if using two telephone lines for communication. D192G Class "B", Style V Bell Circuit Opt. Opt. Opt. Opt Opt. Opt Req. Req. Req. Req. Req. Req. Supervision 0268/0269H Independent Zone Optional. Only connect to Zones 1 to 8. No No No No No No No Control DS7432 Eight Input Remote Module Opt. Opt. Opt. Opt Opt. Opt. Opt. Opt. Opt Opt. Opt. Opt. DS7457iF Single Zone Input Module Opt. Opt. Opt. Opt Opt. Opt. Opt. Opt. Opt Opt. Opt. Opt. DS7560i Dual Zone Input Module Opt Opt. Opt. Opt Opt. Opt Opt Opt. Opt. Opt Opt. Opt. DS7461i Single Zone Input Module Opt. Opt. Opt Opt Opt. Opt. Opt. Opt. Opt. Opt. Opt Opt. DS74651 Input/Output Module Opt Opt Opt Opt. Opt. Opt. Opt Opt. Opt Opt. Opt. Opt D130 Relay Module Opt Opt Opt. Opt Opt. Opt Opt. Opt. Opt Opt. Opt. Opt. D1255 and 01260 Keypads Opt Opt. Opt. Opt. Opt. Opt No No No No No No No 01256 Command Center and 01257 Opt. Opt Opt Opt. Opt. Opt No No No No No No No Annunciator 01255B and 0126013 Keypads Opt Opt. Opt. Opt Opt Opt. No NojNo No No No No D1255RB, D1256RB, 01257RB No Opt. Opt No No No Req. Req. Req. Req. Req. Req. D1640 Transformer Required for all applications. D8004 Transformer Enclosure Opt I Opt Opt. I Opt. Opt. Opt. Req. Req. Req. J Req. Req. [Req. 08125 Class B, Style 4.0 POPEX Required for the D91271/U POPITs. Module 08125MUX Class B Style 4.0 Required for MUX devices Refer to Section 7.1 D8I25MUX on page 21 091271/U Class B, Style A POPIT Opt. Opt. Opt Opt Opt Opt. Opt Opt. Opt. Opt. Opt. Opt Modules 081280 OctoPOPIT Opt. I No I Opt. Opt. Opt. Opt. Opt. Opt Opt. I Opt I Opt. 10pt. Opt. 08129 OctoRelay Optional. For remote annunciation of system functions. 08130 Release Module Opt I Opt I Opt. I Opt, Opt. Opt. Opt. Opt. Opt Opt. Opt. Opt. Opt. 08132 Battery Charger Refer to Table 5 on page 23. No No No No No No No D9131A Parallel Printer Interface Opt No No Opt. Opt Opt. No No No No No No Opt. 09210B Access Control Interface No No No Opt Opt Opt. Opt Opt. Opt. Opt. Opt. Opt No * The D125B is required to connect two-wire fire alarm initiating devices. The D125B provides two powered loops for connecting listed two-wire smoke detectors. The D129 provides two non-powered Class 'A" initiating circuits. 14 Bosch Security Systems, Inc. 1 2/1/2010 1 F01U143069-01 1 - If required by local AHJ, connect Dl 13 Battery 9 - To Relay A or Relay B Lead Supervision Module. 10 - Listed Audible Signaling Devices rated at 2 Batteries 12.0 VDC nominal (do not use vibrating type D122 Dual Battery Harness, as required horns) D1640 Transformer and D8004 Transformer 11 - C900V2 or C9007TL-E (optional) Enclosure required for NFPA Applications 12 - RJ31X, secondary phone line D8132 Dual Battery Charger with two batteries 13 560 ), 2 W EOL Resistor (Batteries are not supervised) (P/N: 15-03130-005) Power limited, supervised 14- RJ31X, primary phone line Power limited 15- 0928 D 192 Bell Supervision Module 16- To earth ground All external connections except Terminal 5 (battery positive) are power limitd. Bosch Security Systems, Inc. 1 2/10 I F01U143069-01 15 D9412GV3/D7412GV3 Approved Applications Compliance Guide I System Wiring Diagramsthsie A Figure 5: D9412GV3, System Wiring Input Points and Peripheral Devices 1 - (Optional): For 24 V applications use a UL Listed 24 VDC power supply with a D130 Relay Module. Refer to the D130 Installation Instructions (P/N: F01 U072455) for correct wiring requirements. D130 Relay Module D125B Powered Loop Interface Module To UL Listed two-wire smoke detectors. Refer to Two-Wire Smoke Detectors in the D9412GV3/D7412GV3 Approved Applications Compliance Guide (P/N: F01U143069) fora listing of compatible two-wire smoke detectors. P105F 1 k12 EOL resistor (P/N: 14-03130-004): Suitable for non-powered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. P105BL1 ikO EOL resistor (P/N: 16179B): For typical burglar alarm applications. D129 Dual Class A Initiation Circuit Module: Provides optional Waterfiow Alarm Retard feature. Not suitable for two-wire smoke detectors. Use zero retard except for waterflow devices. All external connections except Terminal 5 (battery positive) are power limited. 16 Bosch Security Systems, Inc. I 2/1/2010 I F01U143069-01 D9412GV3/137412GV3 Approved AppItcationsCompliance Guidë'I 7 0 . i awe : Lurrenx uiaiung i..nart ior zianuoy battery I...aicuuauons A B . C AC Power On AC Power Off In Alarm Normal Current (mA) Minimum Current (mA) Maximum Current (mA) Model Number Qty Ea nit, Qty Total Unie TEach otal Each Qty Total Used D412GV 225 xl =225 225 xl =225 300 1 =300 D125B 25 xQty = ------ 25 xQty = ---168 xQty = .D127 • 5. xQty L -5 xQty -••55 xQty=___j. D129 23. . xQty = ------23 xQty = 25 xQty .= ------ D185 .245 xQty = 245 -x Qty 300 xQty D192G 35 xQty = ------. 35- . xQty =..-. 100. xQty = ----- D1255/D12558 104 x Qty 106 x Qty = 206 x Qty = D1256/D1257 104 . xQty = 106 . . xQty = -------206 xQty D1255.RB .104 xQty -- 106 XQtY . -:-. 225 xQty- D1256RB 104 x. Qty = -------106 xQty = ------225 xQty = D1257RB 104 xQty 106 . xQty = ------225 xQty D1260/D126013 140 xQty = ------140 xQty = ------250 xQty = 15720 .20 xQty = ------20 xoty = 100 xQty D8125 60 xQty = ------60 xQty = ------60 xQty = 6S125MUX1 D8128D 25 xQty =25 xQty =50 xQty = 68129 - 20 x Qty = 20 x Qty = Refer to footnote2 D8130 7 xQty = ------7 xQty = ------60 xQty = D91271/U 0.8 xQty =_ 0.8 xQty 0.8 xQty = D9131A 21 xQty = ------21 xQty = ------23 xQty D9210B 110 xQty = ------110 xQty = ------i103 xQty = D928 20 xQty = ------20, xQty 100 xQty = DX 40101 50 xQty = 50 xQty = 55 xQty DX4020i 80 xQty = -80 xQty =84 xQty = Ratings of other devices in the system that are not shown above: xQty = ------- xQtyQty = xQty = x QtyQtx = ___ Qty xQty = ------- xQty = City = xQty = ------- = -x x Qty Qty = Qty = ------- xQty = ------ TotalA= Total = Total = 1 Refer to Table 4 on page 22 to determine maximum currents for the D8125MUX and its accessories. 2 The In Alarm calculation for the D8129 Is: 20 x Qty + (16.25 x number of relays) Use 110 mA + reader current. Do not exceed 260 mA. Bosch Security Systems, Inc. 1 2/10 1 F01U143069-01 . 23 UL 365 requires 72 h of standby battery capacity. Limit the auxiliary power current for. all devices, including keypads, to 300 mA or less to meet this requirement Table 6 Standby Battery Requirements Type Required Capacity . Calculations Household Burglary and Commercial 4 h Burglary * Bank Safe and Vault 72 h (UL 365) Auxiliary power current for all devices including keypads must be limited to 300 mA or less to meet this requirement. Central Station or Local Fire Alarm , .24 h + 5 min of alarm operation. Refer . - to Table 8 on page Remote Station or Auxiliary Fire 60 h + 5 min of alarm operation. Alarm . , , . Refer to Table 9 on page 25. . Household Fire Warning Equipment 24 h + 4 min of alarm operation. Refer to Table 10 on page 26. 8.3 Standby Battery Calculation :Because of changing regulations, verify the necessary time with your local authonty having risdiction (AHJ) Refer to Table 5 on page 23 for totals B and C used in the formulas below. When connecting two batteries, use either the D122 Dual Battery Wiring Harness or the D8132 Battery Charger Module. Table 7: General Ampere-Hour (Ah) Calculation Formula Total B1 Hours Total C1 Alarm Operation Contingency Total Ah3 x 24) + ( x 666i) + 10% = 1 Refer to Table 5 on page 23. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not exceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two .D1218 Batteries = 34.4 or 36 Ah 24 . , Bosch Security Systems, Inc. 1 2/1/2010 1 F01U143069-01 8.4 Central Station or LOcal Sy items : Central Station or Local Systems require 24 h of standby plus 5 min of alarm operation at the end of the 24-hour period. A single battery is sometimes adequate for central station systems, but two batteries must be installed to meet the basic standby requirements for a local system installation. Use the battery ampere-hour (Ah) calculations to confirm compliance. The formula in Table 8 includes the calculation for 5 min of alarm operation at the end of the 24-hour period, as well as a 10% contingency factor that allows for depletion of battery capacity with age Because of changing regulations, verify the necessary time with your local AHJ (authority having jurisdiction) S Table 8 Central Stations or Local Systems Ah Calculation Formula Total B1 Hours Total C' Alarm Operation Contingency Total Ah3 x 24) +" (_ x 0 083) + 10% = 1 Refer to Table 5 on page 23. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not exceed the Ah capacity of batteries: One D126 Battery= 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two D1218 Batteries = 34.4 or 36 Ah 8.5 Remote Station or Auxiliary Systems Remote Station or Auxiliary Systems require 60 h of standby plus 5 min of alarm operation at the end of the 60-hour period. A D8132 Battery Charger Module with additional batteries installed in a separate D8109 or D8108A Enclosure might be required in the system to meet the basic standby requirements for a remote station or auxiliary system installation. Use battery Ah calculations to confirm compliance. The formula in Table 9 includes the calculation for 5 min of alarm operation at the end of the 60-hour period, as well as a 10% contingency factor that allows for depletion of battery capacity with age. Because of changing regulations, verify the necessary time with your local AHJ (authority having jurisdiction). Table 9: Remote Station or Auxiliary Systems Ah Calculation Formula Total B' Hours Total C' Alarm Operation Contingency Total Ah3 x 60) + ( x 0.083) + 10% = 1 Refer to Table 5 on page 23. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not exceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two D1218 Batteries = 34.4 or 36 Ah Bosch Security Systems, Inc. 1 2/10 I F01U143069-01 25 HI .. . . ... • . 8.6 Household Fire Warning Equipment The Household Fire Warning Equipment Standard requires 24 h of standby current plus 4 nun of alarm operation at the end of the 24-hour period. Use battery Ah calculations to confirm compliance. The formula in Table 10 - includes the calculation for 4 min of alarm operation at the end of the 21-hour period, and a 10'i, contingency factor that allows for depletion of batters' capacity with age. Because of changing regulations, verily the necessary time with your local AHJ (authority having jurisdiction). Table 10: Household Fire Ah Calculation Formula Total Bt Hours Total C1 Alarm Operation2 Contingency Total Ah3 ( x.24) 0.067) •+ 10%.'=___..._. 1 Refer to Table 5 on page 23. 2 Value Minutes of alarm operation, 60 3 Total Ah requirements must not exceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One 01218 Battery = 17.2 or 18 Ah Two 01218 Batteries = 34.4 or 36 Ah 8.7 UL 609 The leads providing operating power to the alarm sounding device shall be electrically and mechanically protected as required in the Standard for Installation and Classification of Mercantile and Bank Burglar-Alarm Systems, UL 681, or the circuit shall be constructed so that the system is not defeated by cutting or short-circuiting connections between the control unit and the alarm housing. The alarm housing for a bank alarm system without a remote alarm transmission connection shall be mounted on the outside of the building, visible from a public street or highway. It shall be accessible for examination and repair. It shall also be located not more than four stories above the street level unless: A second alarm sounding device and housing, intended for outside service [see 3.3(a)??], is mounted adjacent to the premises or area of the building in which the alarm system is installed or A second alarm sounding device, intended for inside service [see 3.3(b)??], is mounted within the premises. In either case, the outside alarm sounding device and housing may be mounted as high as the seventh floor. 8.8 UL 365 In a mercantile burglar alarm system, a mercantile alarm sounding device located within a building but outside the protected area, is acceptable, provided it is rated for outside service and alarm conditions are transmitted to: a. The dispatch location of the law enforcement agency having jurisdiction over the protected property or A central station or residential monitoring station complying with the Standard for Central-Station Alarm Services, UL 827. In a mercantile burglar alarm system, an alarm sounding device located within the area of greatest protection, or outside the area of greatest protection but within an area protected by an alarm system and that shares a common control unit with the system installed in the area of greatest protection, is acceptable provided it is rated for inside service and alarm conditions are transmitted to: The dispatch location of the law enforcement agency having jurisdiction over the protected property or A central station or residential monitoring station complying with the Standard for Central-Station Alarm Services, UL 827. 26 Bosch Security Systems, Inc. 1 2/1/2010 1 F01U143069-01 Bosch Security Systems, Inc. I 2/10 I F01U143069-01 27 LISTING No. 7165-1615:0238 Page 1 of 2 CATEGORY 7165 FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email jon.wolski@us,.bosch.co.m DESIGN: Models D7412GV3 and D9412GV3 fire alarm control units. Inherently power-limited; remote station central station and local service Refer to listee s data sheet for detailed product description and operational considerations System components.. D1221D122L Dual Battery Hardness DI 2513" Powered Loop Interface Module D928;.Dual Phone Line Switcher Module D129 Dual Class A Initiating Circuit Module D130; Relay Module D192G Notification Appliance Circuit Module D1640 Class 2 Transformer D8004 Transformer Enclosure D8125MUX; POPEX Module D8129; OctoRelay Module D8130; Door Release Module D921 0B, D92IOBC, D921OBLC; Access Control Interface Module DX4020; Network Interface Card ITS-DX4020-G; GPRS/GSM IP Communicator D9127T/D9127U; POPIT Module D8128D; OctoPOPIT Module D1255RB/D1256RB1D1257RB; Keypads/Annunciators D8125; Zone Expander Module D9131A; Parallel Printer Interface Module D6600; Receiver 28010 (27 K Ohm)/15-03130-004(1 K Ohm)! 15-03130-005(560 Ohm)/25899 (2.21 K Ohrn)i; EOLR Resistors D8103/D8108/D8108A; Enclosures ICP-SDI-91 14; SDI Splitter/Isolator Module D57432; Multiplex Expander Module DS7457iF/DS7461i; Single Zone Multiplex Input Module DS7460i; 2-Zone Expander DS7465i; Input/Output Multiplex Module *B450; Interface Module *B440 B441; Cellular Module *Rev 04-22-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator )1 S±4 F/1 Cf Fire Engineering Division INSTALLATION In accordance with the listee s printed installation instructions applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING Listee s name model number, electrical rating and UL label APPROVAL Listed as fire alarm control units for use with separately listed..compatible initiating and indicating devices Refer to listee s Installation Instruction Manual for details These control units can generate a distinctive three pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72 2002 Edition Refer to manufacturers installation instruction manual for details Authority having jurisdiction shall be consulted prior to installation. These control units meet the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification Feature (delay of alarm signaling), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-22-14 gt ørs . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division OW SOSCH'. Invented for fife- 0- Provides point identification of initiating devices Supervises wiring to devices for circuit integrity Expands the number of points in the system Compact size Terminal connections for reliability The D9127 Series POPIT Modules includes the D9127T (with magnetic tamper switch) and the D9127U (without tamper). They are used with a D8125 Addressable Expansion Module when there is a need to expand a compatible control panel beyond its standard number of on-board initiating zones or points. Future system expansion is very economical as D9127 Series POPITs can be added anywhere along the two-wire data expansion loop from the D8125 module. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 kC) end-of-line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed ir standard outlet boxes, above false ceilings, closets, or other accessible locations. Region Certification USA Ut UL UL 365-Police Station Connected Bur- glar Alarm Units UL UL464- Standard for Audible Signal Ap- pliances UL UL 609 Standard for Local Burglar Alarm Units and Systems UL UL 864- Standard for Control Units and Accessories for Fire Alarm Systems UL UL 985-Household Fire Warning Sys- tern Units UL UL 1023-Household Burglar Alarm Sys- tern Units UL UL1076- Proprietary Burglar Alarm Units and Systems UL UL1610-Central Station Burglar Alarm • Units UL UL 1635 -Standard for Digital Alarm Communicator System Units FM Region eication D8125 to POPIT Loops S - Use one two-wire data expansion loop, or distribute CSFM see our websité . . the POPITs on up to three loops. The maximum - 6059 [D9412GV3&D7412Gv3] lengths shown in the following table are for all data CoA - . expansion loops combined connected to the same - . - - . D8125 module. Setting DIP switches on the POPIT ' 6174 CoA ' S , modules assigns them to point numbers. The switch setting on each POPIT assigns it a point number, FDtY- 6196 . ' ' - S regardless of its physical location. CoA S Australia , ClICK, . S ' - •' '. POPIT to Sensor Loops S C-Tick,.. .... , -. : . The number of detection devices each sensor loop can Canada -ULC AMCX7 S1871 CentralStationAlarm supervise is limited only by the resistance on the loop Units Certified for Ca ada Resistance on each sensor loop must be less than ' ' S ULC AOD(7.S1871 Local iar-n Units Certi- . 1000 not including the end-of-line (EOL) resistor.:' fied for Canada Certain UL and National Fire Protection Association S ULC. .• S , APAW7.S1871Pclice-stationconnec- (NFPA) applications can limit the number of detection . . S tedAlarmUnitsC&tifiedforCanada. ,. .• . . devices. Consult the appropriate UL or NFPA standards. ULC , APQU7.S1871 Proprietary Alarm, Units . " Certified for Canada Terminate each POPIT sensor loop with the 33 kO EOL resistor included with each POPIT. ULC NBSX7 S1871 I-ouse-iold BurgiarAlarm Use a twisted pair wire (six twists per foot) in all System Units Certifi&rforCanada POPIT installations for both the data expansion loop rrnlrPtyLT1tTT S . ration 1notes wiring and the POPIT sensor loops. Run wires away from AC sources to prevent AC induction. Compatibility Information ______________________________________________ Control Panels tll'G Series control panels, D9412, D7412, 317212, D7212131, D9112, 09112131, 38112131, D8112132, and D9124 Module 08125 The D8125 Multiplex Zone Expander is required. The D9127 modules ae wired in parallel on :he D8125 data loop. Number of POPIT Modules per Control Panel D7212G, D72120V2, C7212GV3 22 D9127 POPITs D7212B1 40 D127 POPITs 07212,07412. D'4123, D7412GV2, 67 DS 127 POPITs 074 12GV3 D9124 119 03127 POPITs D9112B1 126D9127POPITs 09112, 09412, D6412G, )9412GV2, 238 D9127 POPITs D9412GV3 Wiring Considerations Wire Size Maximum Length of'all Data Expansion Loops Combined 0.8 mm (22 AWG) 549 m (1800 ft} 1.0 mm (20AWG) 881 m (2890 ft) 1.2mm(18AWG) 1402m(4600f1) 1.5mm(16AWG) 2231 m (7320 ft) 1.8mm(14AWG) 3551m(116501t) Quantit Component Y 1 POPIT module 1 33 kO EOL resistor 1 Magnet (D9127T only) 1 Hardware pack 1 Literature pack .Technical specifications: Environmental Considerations Relative humidity Up to 93% non-condensing Temperature 0°Cto+50°C(+32°Fto+12rF) (operating) Properties Color 5- 5-.--- Off white Dimensions 8.1 cm 3.8 cm 2.4 cm (3.2 in. x 1.5 in. x 0.9 in.) Material ' UL Listed fire-resistant S Represented by, Americas, Europe, Middle Last, Africa, Asia-Pacific, Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security 130 Perinton Parkway P.O. Boo 80002 Systems Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 Phone: +1 800 289 0096 Phone: * 31402577 294 Singapore 573943 Pam +1585 223 9180 Pam +3140 2577 330 Phone *65 6571 2808 security.sales@us.bosch.com emea.securitysystems@bosch.com Pam .65 6571 2699 www.boschsecurity.us - www.boschsecurity.com apr.securitysystems@bosch.corn www.boschsecurity.asia C Bosch Security Systems 20161 Data subject to change without notice 25381784431 an, y1, 22. Jon 2016 China, America Latina, Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 203 Building, No. 333 Fuquan Road Via Anhaoguera, Km 98 North IBP CEP 13065-900 Changoing District, Shanghai Campinas, Sao Paulo, Brazil 200335 China Phone *55 19 2103 2860 Phone *862122181111 Fax +55 19 2103 2862 Pam .86 21 22182398 Iatam.boschsecurity@bosch.com www.boschsecarity.com.cn - www.boschsecurity.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1615:0242 Page 1 of 2 CATEGORY: 7165 -. FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMSI30 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email jon wolskl@us bosch com DESIGN: Models D7412GV4 and 09412GV4 fire alarm control units. Inherently power-limited; . . . remote station, central station and local service. Refer to listee's data sheet for. detailed product description and operational considerations. System components:. 0122/D122L Dual Battery Hardness . D12513; Powered Loop Interface Module D928; Dual Phone Line Switcher. Module .0129; Dual Class A Initiating Circuit Module . . D130; Relay Module . . . . D1 92G, Notification Appliance Circuit Module D1640; Class 2 Transformer . . . D8004; Transformer Enclosure . . . . D8125MUX; POPEX Module D8129; OctoRelay Module D8130; Door Release Module 0921013, D921013C, D9210BLC, 09210C; Access Control Interface Module DX4020, B420; Network Interface Card ITS-DX4020-G; GPRS/GSM IP Communicator 09127T/09127U; POPIT Module D8128D; OctoPOPIT Module D1255RB/01256RB/01257RB; Keypads/Annunciators D8125; Zone Expander Module 09131A; Parallel Printer Interface Module 06600; Receiver 28010 (27 K Ohm)/15-03130-004(1 K Ohm)/ 15-03130-005(560oOhm)/25899 (2.21 K Ohm)i; EOLR Resistors 08103/08108/D8108A; Enclosures ICP-SDI-91 14; SDI Splitter/Isolator Module B208; Input Module B308; Output Module 0S7432, DS7457iF, DS7460i, DS7461i, DS7465i; Multiplex Modules B440, B441, *13443; Cellular Modules B450; Interface Module 08109, BATB-40, BATB-80; Enclosures *Revisiorl 09-20-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct kAV, operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 19, 2018 . . Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No 7165 1615;.0242 Page .2 of 2 INSTALLATION In accordance with the listee's printed installation instructions applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three- pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's installation instruction manual for details. Authority having jurisdiction shall be consulted prior to installation. These control units meet the requirements of UL Standard 864, 9th Edition. *Revision 09-20-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 19, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division www.boschsecurity.com 0 BOSCH Invented for life II!o. Two-wire or four-wire bases /v lo, 30 ft (9 m) maximum spacing between detectors / Optional CO-sensor, heat-sensor enhanced detection chamber eYA o Clean chamber without removal Iftjj) : or disassembly oo. The F220 Photoelectric Smoke Detectors are UL Listed, open-area photoelectric smoke detectors. Use them with commercial fire protective signaling systems and household fire warning systems (see NFPA 72, the National Fire Alarm Code). These smoke detectors scatter light using a pulsed infrared source operating with a gated, high-speed, photodiode infrared sensor. The symmetry of the optical chamber allows 3600 uniform smoke entry, but minimizes external light entry. The detectors use low current electronic circuitry, so they can connect to 12 VDC nominal or 24 VDC nominal power source circuits. Compatible Bases Configure the detectors into two-wire or four-wire versions by selecting the appropriate mounting base. These detectors are compatible with any of the F220-136 bases: F220-136 12/24 VDC Two-wire Mounting Base F220-B6R Standard 12/24 VDC Four-wire Mounting Base F220-B6RS 24 VDC Four-wire Mounting Base with Sounder F220-B6C 12/24 VDC Four-wire Mounting Base with Auxiliary Relay F220-136E 12/24 VDC Four-wire Power Supervision Mounting Base F220-B6PM 24 VDC Four-wire Addressable Master Base F220-136PS 12/24 VDC Four-wire Addressable Base Monitoring the Detection Chamber These detectors have several features that work together to maximize the performance of the optical chamber: Compensation: The detector monitors the chamber for the effects of dust build-up within the chamber and automatically compensates for these effects. If the chamber becomes contaminated beyond its ability to compensate, the green LED flashes every 4 sec to indicate trouble. Chamber Check Self-diagnostics: The detector automatically indicates visually if the calibration is out of the factory-listed range. This meets NFPA guidelines for sensitivity testing, because you can visually inspect the detector and check the flash rate of the LED. If the calibration is out of range, the green LED on the detector flashes once every 4 sec. This indicates that the detector must be cleaned following the instructions provided with the detector. 2 I F220 Photoelectric Smoke Detectors CleanMe Mode: Indicates if the calibration is out of the factory-listed range by sending a trouble signal to the CleanMe-compatible control panel, if so programmed. Chambermaid: The detector has a unique cleaning mechanism. Use the valve on the back of the detector to insert the nozzle of a can of clean, dry compressed air. Clean the chamber with a short (1 to 2 sec) blast of air. Heat and Carbon Monoxide Enhancements The detectors are available with an optional fixed- temperature heat sensor, a carbon monoxide (CO) sensor, or a combination of heat and CO sensors. These optional sensors enhance the operation of the smoke detector by reducing false alarms. Carbon Monoxide: Without the presence of CO, a normal byproduct of combustion, the detection chamber is half as sensitive to smoke as a standard commercial photoelectric smoke chamber. This reduces false alarms. When the sensor detects CO, the detection chamber's sensitivity to smoke increases so it equals or exceeds that of a standard commercial photoelectric smoke chamber. Notice The F220-PTHC detects carbon monoxide (CO) as a component of a fire. It is not a CO detector and cannot activate an alarm in the presence of CO only. Heat: When the heat sensor detects a temperature rise, the photoelectric chamber becomes more smoke sensitive. The heat sensor initiates an alarm if the ambient temperature exceeds +135°F (+570C). Dual-color LED A dual-color LED indicator flashes green every 8 sec when the detector has power and the smoke sampling circuitry is working. If CleanMe is enabled, the green LED double flashes (two flashes a half second apart) every 8 sec to indicate normal operation. The LED turns red if an alarm is sent. After the alarm condition clears, reset the detector by interrupting its power. If the chamber becomes contaminated beyond its ability to compensate, the green LED flashes every 4 sec to indicate trouble. Test Functions The F220 Photoelectric Smoke Detectors feature a unique magnet operation and sensitivity test function. Test the detector's operation by placing the magnet next to the detector's LED for three consecutive flashes. This causes the detector to send an alarm. Placing a magnet next to the detector's LED for at least one red flash but less than three flashes activates the detector's sensitivity mode. Tamper Detection When detector heads are correctly installed in any of the F220-B6 bases, the positive power line provides tamper detection. The control panel initiates a trouble signal if a detector is removed from its base. A mechanical tamper lock comes with each base to prevent unauthorized head removal. Region Certification 1 Europe CE 89/336/EEC, EN50130-4/A Sept 1998, EN61000-6-3 Oct 2001 USA UL UROX: Smoke-automatic Fire Detectors (ANSI/UL 268), UROX7: Smoke-auto- matic Fire Detectors Certified for Cana- da (CAN/ULC-S529) FM F220 Smokes CSFM see our website NYC- 117-05-E MEA MSFM 2200 Sep 2008 Hong Kong HKFSD (P and PTH only) Compatible Control Panels Addressable Systems: compatible with addressable systems controlled by B9512G, B8512G, D9412GV4, D7412GV4, D9412GV3, D7412GV3, D9412GV2, D7412GV2, D9412G, or D7412G Control Panels or the D9124 Fire Alarm Control Panel when used with the F220-B6PM or F220-B6PS Addressable Detector Bases. Iwo-wire: Bosch Security Systems, Inc. makes no claim written, oral, or implied that the F220 Photoelectric Smoke Detectors work with any two- wire control panels except those specified in the Control Panel Compatibility chart in the Technical Service Note (P/N: 4998148185). Four-wire: compatible with all UL Listed four-wire control panels. Refer to the control panel's installation instructions for proper end-of-line (EOL) resistor selection. Mounting the Bases 51 Notice Consult NFPA-72 for proper detector placement. Depending on local regulations, the bases can be surface mounted directly on four-inch square or octagonal electrical boxes and single-gang switch boxes. Notice The volume of any electrical box used should be large enough to accommodate the number and size of conductors as specified by the National Electrical Code or any local authorities having jurisdiction (AHJ). Loop Supervision Loop supervision requires one D275 or F220-136E per loop when using F220-B6R/B6C bases and is supervised by the control panel. Wiring the Bases Refer to the F220 Series Detectors with F220-B6/C/E/R Bases Installation Instructions (PI N: 4998138694), the F220 Series Detectors with F220-136RS Bases Installation Instructions (PI N: F01U029847), or the F220-136PSIM Installation Instructions (P/N: 4998149982) for detailed wiring instructions. Quan Component tity 1 Detector with dust cover Environmental Relative Humidity: 0% to 95% non-condensing; 15% to 95% non-condensing for CO sensing model Temperature (normal +32°F to + 100°F (0°C to +38°C) operating): I Mechanical Color: White Dimensions 6.75 in. x 2.25 in. (17.1 cm x 6.4 cm) (diameter x H): Electrical Current (alarm): 20 mA minimum at 8.5 VDC; (detector head only) 35 mA maximum at 32 VDC Current (start-up! 0.12 mA maximum at 32 VDC standby): Maximum RMS Ripple: 251/o of DC input Power-up Time: 22 seconds maximum Voltage (standby) F220-136: 8.5VDCto32.OVDC F220-B6C/-B6R/-B6E: 1 10.0 VDC to 30.0 VDC F220-13611S: I 16.0 VDC to30VDC F220-136PM: with D299: 18.9 VDC to 28.0 VDC without D299:9.6 VDC to28.OVDC F220-136PS: I 18.9 VDC to28.OVDC Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. F220-PTHC Photoelectric Smoke Detector with +135°F (+57°C) Heat and Carbon Monoxide Sensors Photoelectric detector head with heat and CO sensor augmentation only; requires base. Order number F220-PTHC F220-PTH Photoelectric Smoke Detector with +135°F (+57°C) Heat Sensor Photoelectric detector head with heat sensor only; requires base. Order number F220-PTH F220-P Photoelectric Smoke Detector Photoelectric detector head only; requires base. Order number F220-P Accessories D275 Power Supervision Module Line supervision device for four-wire fire detection circuits Order number D275 DRA-5 Remote Annunciator (5 VDC) Designed to provide remote annunciation of alarms for a number of Bosch smoke and heat detectors Order number DRA-5 DT-2 Detector Removal Tool Use the DT-2 to remove, replace, or test the detector head Order number DT-2 F220-1136 12/24 VDC Two-wire Base Standard base for two-wire (12 VDC or 24 VDC system) applications. Order number F220-B6 F220-1136111 Standard 12/24 VDC Four-wire Base Standard base for four-wire (12 VDC or 24 VDC) detector systems. Order number F220-B6R F220-1136RS 24 VDC Four-wire Detector Base with Soun- der Four-wire detector base with sounder for use with the F220 Photoelectric Smoke and Heat Detectors. Order number F220-B6RS 117220-1136C 12/24 VDC Four-wire Base with Auxiliary Form C Relay Four-wire base with a normally-open (NO) alarm loop relay and a set of auxiliary contacts (Form C). Order number F220•B6C F220-1136E 12/24 VDC Four-wire Power Supervision Base with End-of-line Power Monitoring Relay Four-wire base with a normally-open (NO) alarm relay and an EOL power supervision relay. Order number F220-B6E 4 I F220 Photoelectric Smoke Detectors F220-B6PM 24 VDC Four-wire Addressable Multiple De- tector Base The multiple detector base provides an address on the FACP data expansion circuit for its detector and up to an additional 19 detectors. It accepts the F220 Photoelectric Smoke Detector Heads and Heat Detector Heads. Order number F220-B6PM F220-136PS 12/24 VDC Four-wire Addressable Single De- tector Base The single detector base provides an address on the FACP data expansion circuit for its detector. It accepts the F220 Photoelectric Smoke Detector Heads and Heat Detector Heads. Order number F220-B6PS Represented by: North America: Europe, Middle East Africa: Asia-Pacific: China: Latin America and Caribbean: Busch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd. Security Busch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway P.O. Box 80002 Systems 203 Building, No. 333 Fuqaan Road Via Anhanguera, Km 98 Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone: -1 800 289 0096 Phone: 0 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil Fax: +1585 223 9180 Fax: +3140 2577 330 Phone: 065 6571 2808 200335 China Phone: n55 19 2103 2860 security.sales@os.bosch.com emea.seouritysystems@bosch.com Fax: *63 6571 2699 Phone *86 21 22181111 Fax: 055192103 2862 www.boschsecurity.os www.boschsecurity.com apr.securitysystems@bosch.com Fax: *86 21 22182398 latam.boschsecurity@bosch.com www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecurity.com 05 Bosch Security Systems 2016 I Data subject to change without notice 2701164683 1en, V9, 04. Mar 2016 Alarm Current (only base current, detector current excluded) F220-B6: Two-wire .base; no base current F220-B6C: 31 mA at 12 VDC 35 mA at 24 VDC 40 mA maximum at 30 VDC F220-B6E: 25 mA at 12 VDC 30 mA at 24 VDC 34 mA maximum at 30 VDC F220-B613: • 13.5 mA at 12 VDC 16.5 mA at 24 VDC. 19 mA maximum at 30 VDC Standby Current F220-B6/C/R: No current draw in standby F220-B6E: 16 mA maximum at 30 VDC Voltage F220-B6 (two-wire): 8.5 VDC to 32.0 VDC F220-B6C/E/R (four-wire): 10.0 VDC to 30.0 VDC Table 2.4 F220-136 Series Base Specifications 2.3.3 Detector Specifications Current Alarm: 20 mA minimum at 8.5 VDC 35 mA maximum at 32 VDC Standby: 0.12 mA maximum Startup: 0.12 mA maximum Powerup Time 22 second maximum Rate of Rise F220-135: 150F/mm (91C min) or greater Voltage Operating: 8.5 VDC to 32.0 VDC RMS Ripple: 25% of DC input Table 2.5 F220 Series Detector Heads Specifications 2.4 Electrical Supervision When the F220-B6 Series Bases are wired according to the instructions in this document, the control panel initiates a trouble signal when a detector is removed from its base, Bosch Security Systems, Inc. Installation Manual 4998138694 -04 12007.01 F220 Series Detectors with F220 B6/C/E/R Bases Install the Bases I en 15 unnecessary. Use only One F220-136E per zone run. It must be the last base on the run. Refer to Figure 3.4 for wiring details. b2b F22OB6E* A al/a2 c 1. Power input (positive [+] previous four-wire base. in on terminal b2; negative Jumper connecting [-1 in on terminal al/a2) terminals 2 and 3. from the control panel or Place an appropriate EOL from a previous four-wire resistor (refer to the base. control panel's installation 2. Initiating device circuit instructions for resistor (lDC) input (positive {+} to specifications) across terminal 2 and negative [-1 Terminals 1 and 4. to terminal 1) from the Power Supervision Relay control panel or from a Alarm Loop Relay Fig. 3.4 Wiring F220-136E Four-wire Power Supervision Bases * F220-136E Bases can only be used at the end of a loop. The alarm loop relay (Form A, Terminals 1 and 2) and the power supervision relay (Terminal 3 and 4) are rated for 0.5 A at 120 VAC/DC for resistive loads. Bosch Security Systems, Inc. Installation Manual 4998138694 -04 1 2007.01 b220-libU - c4)r.ava2c 14 en :l Install the Bases F220 Series Detectors with F220 B6/C/E/R Bases 3.5.1 F220-B6C: The F220-B6C base has a normally open alarm loop relay and auxiliary Form C (NC/C/NO) contacts. The contacts are rated for 0.5 A at 120 VAC/DC for resistive loads. Refer to Figure 3.3 for wiring details. Power input (positive [+] from terminal 4) from the in on terminal b2, out from control panel or from a terminal bi; negative [-] in previous four-wire base and out from terminal and output to the next al/a2) from the control four-wire base or to loop panel or from a previous termination (refer to four-wire base and output Figure 3.4 on page 15 to the next four-wire base. [F220-B6E] or Figure 3.6 Initiating device circuit on page 17 [D2751). (IDC) input (positive [+] Alarm Loop Relay inand out from terminal 5 Auxiliary Form C Alarm and negative [-] in and out Relay Fig. 3.3 Wiring F220-136C Four-wire Bases 3.5.2 F220-B6E: The F220-B6E Power Supervision Base has a normally-open alarm loop relay that activates when the unit is in alarm and a power supervision relay that activates when power is supplied. Separate power supervision devices, such as the D275, are 4998138694 -04 1 2007.01 Installation Manual Bosch Security Systems, Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1615:0106 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Models F220-P and F220-PTH photoelectric smoke detectors. Model F220-PTH employs an integral 135° fixed temperature, thermistor type, heat sensor. The heat sensor is intended for use only as a supplement to the smoke detector and is NOT approved for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8.5-32.0 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units and Model F220-136 series detector bases (CSFM Listing No. 7300-1615:105). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 07-21-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 19, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1615:0105 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: BOSCH SECURITY SYSTEMSI30 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolskius.bosch.com DESIGN: Models F220-136(2-wire); F220-136C, -136E, -136R and *.B6RS(4w1re) detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with separately listed Models F220-135 series (CSFM Listing No. 7270-1615:108) heat detectors; Models F220-PC series (CSFM Listing No. 7272-1615:107) or Models F220-P series (CSFM Listing No. 7272-1615:106) photoelectric smoke detectors and compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 19, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division www.boschsecurity.com 0 BOSCH Invented for life 0. Easy wiring Attractive faceplate with highly-visible alarm LED ALARM 0 The DRA-5 Annunciator is designed to provide remote annunciation of alarms for a number of Bosch smoke and heat detectors. It mounts on a single-gang box, or it can be surface mounted. Region Certification USA UL URRQ: Smoke - Automatic Fire Detector Accessories (UL268), URRQ7: Smoke- Automatic Fire Detector Accessories (UL268) Certified for Canada (cULus) FM DRA-5 —H CSFM see our website Compatible Products The following products are compatible with the DRA-5 Remote Annunciator: Category Product ID Product Description Detector D287 Two-wire detector base Bases D292 Four-wire detector base D293A Four-wire detector base with Form C relay D293E Power supervision detector base D2935 Four-wire detector base with sounder Duct D340 Two-wire duct detector housing Detector D341 Four-wire duct detector housing (120 VAC) Housings D342 Four-wire duct detector housing (220 VAC and 240 VAC) D343 Multiplex duct detector housing Wiring Considerations When using 18 AWG (ISO 0.75 mm2) wire, mount the DRA-5 no more than 500 ft (152 m) from the receiver. When using 22 AWG (ISO 0.34 mm2), mount the DRA-5 no more than 200 ft (61 m) from the receiver. Quan Component tity 1 Annunciator plate 1 Lit - Installation manual Mechanical Properties Dimensions (H xWxD): 4.85 in. x3.1 in. xO.25 in. (12.3 cm x 7.9 cm x 0.6 cm) Power Requirements Current: 10mAat5VDC Voltage: 5 VDC nominal DRA•5 Remote Annunciator (5 VDC) Designed to provide remote annunciation of alarms for a number of Bosch smoke and heat detectors Order number DRA-5 Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina Bosch Security Systems. Inc. Bosch Security Systems B.V. Robert Aosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems td. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway P.O. Boo 80002 Systems 201 Building, Na. 333 Fuquan Road Via Anhanguera, Em 98 Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone: +1800 289 0096 Phone: • 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas, San Paulo, Brazil Fax: +1585 223 9180 Fax: +3140 2577 330 Phone: 065 6571 2808 200335 China Phone: .55 19 2103 2860 security.sulen@un.bosch.com emea.tecuritysystems@bosch.com Fax: +65 6071 2699 Phone .86 21 22181111 Fat: .55 19 2103 2862 www.boschsecurity.as www.boschsecurity.com apr.secoritysystems@bosch.com Fax: +86 21 22182398 latam.boschsecurity@bosch.com www.bonchnecarity.ania www.boschsecurity.com.cn www.bonchsecurity.com © Bosch Security Systems 2014 I Data subject to change without notice 2697192459 en, V3, 30. Jul 2014 Fire Alarm Systems I FMM-100 Series Die-cast Metal Fire Alarm Manual Stations o BOSCH Invented for life FMM-100 Series Die-cast Metal Fire Alarm Manual Stations Single or dual action Terminal connections Gold-plated alarm contacts for corrosion resistance Surface or weatherproof back boxes The FMM-100 Series is a family of versatile, high-quality, metal fire alarm manual stations. Single-action or dual-action models are available. All models come with a key lock and contain gold-plated contacts to resist corrosion. Functions Operation Single-action When the bar on the front of the manual station is pulled, it latches open and is easily visible from 50 ft (15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Dual-action With the dual-action configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. Certifications and Approvals Region Certification USA UL UNlU: Boxes, Non-Coded (UL38), UN1U7: Boxes, Non-Coded Certified for Canada (cULus) CSFM 7150-1615: 224 NYC-MEA 382-94-E or 382-94-E, Vol. 3 Installation/Configuration Notes Compatibility Information Compatible with all Bosch Security Systems, Inc. Fire Alarm Control Panels. Mounting Considerations The FMM Series manual stations can be surface mounted on either the FMM-100BB-R Surface-mount Back Box or the FMM-100WPBB-R Weatherproof Back Box. They can also be flush mounted on a standard single-gang back box. Note When properly mounted on the FMM-100WPBB-R Weatherproof Back Box, these manual stations meet UL requirements for outdoor use. www.boschsecurity.com To comply with ADA standards, the manual station must be less than 48 in. (1.2 m) above the floor for front wheelchair access and less than 54 in. (1.3 m) above the floor for side wheelchair access. Parts 1iijci Quant. Component 1 Manual station 1 D102 Key (1358 key) 1 FMM-100GR Acrylic Break Rod 1 Hardware pack 1 Literature pack Technical Specifications Environmental Considerations Relative Humidity: 90% at +100°F (+38°C) Temperature (operating) -40°F to + 150°F (-40°C to +66°C) Mechanical Properties Color: Red Dimensions (H x W x 0): 475 in. x3.25 in. x 1.1 in. (12 cm 8.3 cm 2.8 cm) Material: die-cast metal Inputs Switch Rating: 1 A at 30 VDC or 125 VAC I Ordering Information FMM-100SATK Single-action Manual FMM-100SATK Station (red) Versatile, high-quality, metal single-action fire alarm manual station with key lock and gold-plated contacts FMM-100SATK-NYC Single-action Manual FMM-100SATK-NYC Station for New York City Versatile, high-quality, metal single-action fire alarm manual station for NewYorkCitywith key lock and gold-plated contacts FMM-100DATK Dual-action Manual Station FMM-100DATK (red) Versatile, high-quality, metal dual-action fire alarm manual station with key lock and gold-plated contacts Accessories D102 Replacement Key D102 Replacement key (#1358) for the 0101 lock. FMM-100BB-R Surface-mount Back Box FMM-100BB-R (red) Red cast-metal back box FMM-100WPBB-R Weatherproof Back Box FMM-100WPBB-R (red) Red cast-metal weatherproof back box FMM-100GR Scored Acrylic Break Rods FMM-100GR Scored acrylic rods (12 per package) Americas, Europe, Middle East, Africa, Bosch Security Systems, Inc. Bosch Security Systems By. 130 Perinton Parkway P.O. Box 80002 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Phone: *18002890096 Phone: • 3140 2577 284 P30: +1585 223 9180 Fax: +3140 2577 330 security.sales@us.bosch.com emea.securitysystems@bosch.com ww-w.boschsecurity.os www.boschsecurity.com 4 Bosch Security Systems Inc. 2010 I Data subject to change without notice T2363731851 (Cur: en-US, V8, 4 Jul 2010 AsiwPauifio, Represented by Robert Bosch (SEA) Pte Ltd, Security Systems :1 Bishan Street 21 Singapore 573943 Phone: *65 6258 5511 Fax: *65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1615:0224 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FMM-100, followed by DAT (Dual Action with terminal strip) or SAT (Single Action with terminal strip) may be followed by K or K-NYC (key lock with single contact) or 2CK (Key lock with dual contacts) noncoded manual pull stations. FMM-IOOBB indoor back box, Suitable for outdoor use when installed with Model FMM-100WPBB back box. *FMM.100DBBR surface mount deep back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Only Models FMM-IOODATK, -100SATK, -100SAT2CK manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Revised 09-01-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division POWER SUPPORT SYSTEM (PSS) iiiiiiiiiiiiiiii 0 lillillillillilI SPECIFICATIONS POWER SUPPLY CHARGER 12 or 24 VDC @: 2.5, 5, 7.5, or 10 Amp Power Limited 3, 6, 9, or 12 Amp Non-Power Limited The AlarmSaf Uninterruptible Power Support Systems (PSS) contain a multi-regulator, float mode power supply/battery charger in a vented locking cabinet. These units are available with power limiting or non power limiting for use as primary or backup DC power systems. The systems are offered in 12 or 24 volt outputs with capacities of 3, 6, 9 and 12 Amps in single output or 2.5, 5, 7.5, or 10 Amps in multi-output power limited systems for power distributed or split load requirements. Cabinet Material B03 18 Gauge Painted Steel B04 16 Gauge Painted Steel Battery Space (Units 6 Amps or lower) B04 - 7"Hx18'Wx4"D - 16.8cm x 46cm x 10.2cm DIMENSIONS Cabinet Size B03 - 11"H x 15w x 4"D - 28cm x 38cm x 10cm B04 - 15"H x 18W x 4"D - 38cm x 46cm x 10cm Input Characteristics Input Voltage: 120 VAC, 60 Hz., Single Phase Input Current: 2 to 10 Amperes (Model Dependent) Output Characteristics Output Voltage: 13.8 or 27.6 VDC Ripple: @ 50% Rated Load < 1% Overcurrent Protection - AC Fuse - Battery Fuse - Electronically Limited Regulators - PTCs (Current Limiting Protection)* Thermal Protection - Transformer Link - Electronically Limited Regulators Battery Chemistry Lead Acid/Gelled Electrolyte *PLS Models only - FEATURES Uninterruptible Power System Thermal & Battery Reverse Polarity Protected Vented Locking Cabinet Interior Battery Space (Model Specific, B04) Visual Indicators AC Presence: Green LED Normal Operation: Green LED Tripped PTC*: Yellow LED Fault Detection Conditions Reported High Battery/Output Low Battery/Output Low AC/No AC/Blown AC Fuse Blown Battery Fuse Tripped PlC Trouble Output Form "C" Relay Contacts —1 A@26VDC - .5A@12OVAC Temperature Range 32°F to 120°F 0°C to 50°C Power Limited Outputs (Available) Fault Detection Available Matching Battery Cabinets PLS Version Power Distributed Continuous Current Ratings UL294 Access Control System Units • Complies with NFPA72 - National Fire Alarm Code UL603 Power Supplies for use with Burglar Alarm Units • CSFM Listed - # 7315 - 1214:102 UL1481 Power Supplies for Fire Protective • MEA Accepted - #MEA - 14 - 93 - E Signaling Systems (NPL Models) AIarmSafo5A Industrial Way, Wilmington, MA 01887-3499, USA, Telephone: 978-658-6717, Fax 978-658-8638, www.aIarmsaf.com I MAXIMUM BATTERY PLUS Selection versus Maximum Battery Size 100 80 a) 60 4° 20 0 PLUS Unit LI PLS-xx025 0 PLS-xx75 fl PLS-xx050 • PLS-xxlO0 N-PLUS Selection versus Maximum Battery Size 160 cD 120 co 00 80 ca 40 NPL-xx030 NPL-xx090 NPL-xx060 NPL-xxl 20 LI Max battery at full current rating of the unit D Max battery at 50% current rating of the unit 0 Max battery at 3 A(NPL-xxl2O only) PLS - Power Distributed Uninterruptible Systems Order Number Model Number System Voltage System Current Cabinet Maximum Battery Capacity Maximum AC Input Current UL Listing 01601 AS/PLS-12025-1303-UL 12 VDC 2.5A B03 34 Ah 1,5A A,B 01602 AS/PLS-12025-1304-1-11- 12 VDC 2.5A B04 34 Ah 1.5A A, B 01605 AS/PLS-24025-1303-UL 24 VJC 2.5 A B03 34 Ah 3.0 A A, B 01606 AS/PLS-24025-B04-UL 24 VDC 2.5 A B04 34 Ah 3.0 A A, B 01608 AS/PLS-12050-B03-UL 12 VDC 5 A B03 50 Ah 2.5 A A, B 01609 AS/PLS-12050-1304-1-IL 12 VDC 5A B04 50 Ah 2.5A A,B 01612 AS/PLS-24050-1303-UL 24 VDC 5 A B03 50 Ah 5.0 A A, B 01613 AS/PLS-24050-1304-UL 24 VDC 5 A B04 50 Ah 5.0 A A, B 01615 AS/PLS-12075-1304-UL 12 VDC 7.5A B04 80 Ah 3.5A A,B 01616 AS/PLS-24075-1304-UL 24 VDC 7.5 A B04 1 80 Ah 7.5 A A, B 01617 AS/PLS-12100-1304-1-11- 12 VDC 10A B04 00 Ah 5.0A A,B 01618 AS/PLS-24100-1304-UL 24 VDC 10A B04 100 Ah 10A A,B NPL - Non-power Limited Uninterruptible Systems Order Number Model Number System Voltage System Current Cabinet Maximum Battery Capacity Maximum AC Input Current UL Listing 01501 AS/NPL-12030-B03-UL 12 VDC 3A B03 40 Ah 1.5A A,C 01502 AS/NPL-12030-B04-UL 12 VDC 3A B04 40 Ah 1.5A A,C 01505 AS/NPL-24030-1303-UL 24 VDC 3 A B03 40 Ah 3.0 A A, C 01506 ASINJPL-24030-1304-UL 24 VDC 3 A B04 40 Ah 3.0 A A, C 01508 AS/NPL-12060-1303-UL 12 VDC 6A B03 70 Ah 2.5A A,C 01509 AS/NPL-12060-B04-UL 12 VDC 6A B04 70 Ah 2.5A A,C 01512 AS/NPL-24060-B03-UL 24 VDC 6 A B03 70 Ah 5.0 A A, C 0151 AS/NPL-24060-B04-UL 24 VDC 6 A B04 70 Ah 5.0 A A, C 01515 AS/NPL-12090-1304-UL 12 VDC 9A B04 120 Ah 3.5A A,C 01516 AS/NPL-24090-1304-UL 24VDC 9A B04 20 Ah 7.5A A,C 01517 AS/NPL-12120-1304-UL 12 VDC 12A B04 160 Ah 5.0A A,C 01518 AS/NPL-24120-B04-UL 24VDC 12A B04 160 Ah 10A A,C UL Listings: Cabinets: A= UL294 - Access Control Systems Units B03= 11 "H x 15' W x 4" D B= UL603 - Power Supplies for use with Burglar-Alarm Units 1304= 15" H x 18" W x 4" D C= UL1481 - Power Supplies for Fire Protective Signaling Systems Al armSaf 65A Industrial Way, Wilmington, MA 01887-3499, USA, Telephone: 978-658-6717, Fax 978-658-8638, www.alarmsaf.com FIreLrreALarms IncorPoraTeD One Fire-Lite Place NoThford, CT 06472 Phone: (203) 484.7161 FAX: (203) 484.7118 0000 0000000 0000000 0000 0000000 0000 000 0000 a a a 00 U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 an ann an no non 0000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0000 000000000000000000000 00000000 0000000 non a no a DOD 0 0 0 0 0 0 0 00 00 00 0 000 0 0 0 0 0 00 0 00 00 FCPS.24F FIREALAIN HELD CNAEDERIPOWER SUPPLY PUP PIPE PROYUCTIOItISIDNSP4O ISPI/ICE 0 E3 00 0 0 00000 0 0 00 P 0 0 000 0 000 0 0 0 0 13 13 0 0 0 0 0 0 0 P 0 0000 0000000 0000 000 0000000 0000 00000000000 coo a a a nan oo 0 0 00 000 a ann oan 0 Don 00 0 0 0 00 0000 0000 0000000 00000000000000 0000 0000000 0000 0000 0000000 0000 000 0000 000 0000 0000 000 0000 0000 0000000 0000 000 0000000 0000 0000 000 0000 FCPS-24F/FCPSm24FE Field Charger/Power Supply Installation, Operation and Application Manual Document 50079 09130199 Revision: IE Title PN 50079:E 09130199 Rl75 JP2C1 D31 i TW In + (Control Input 1 2 In - from FACP) 3 j Out +ffrouble Contact i Out- 6 Trouble Contact 6 In + (Control Input 2 i . fromFACP) r_ Auxiliaiy Output 763 Common Note: Auxiliary Output supplies Specific Application Power, 45 mA Short Circuit System Overview Specifications —To Transformer #2 - To Transformer #1 zx TBI 794 IcI 10 cUe p Icu _ Cut JPltodisable P2 C) R76 battery charger or enable MPM-4 Voltmeter! Ammeter mVo R176 9)Wl R63 Battery fuse I OA, 3AG slow blow I R27 I 192? 1 0000000 vvvvv gm x ToMPM-4 v (Voltmeter/Ammeter) Connection 0 Q4) Figure 1.1 FCPS Board Layout .-' + .+ ,+ ,+ ,- ( rn Title PN 50079:E 09/30/99 ExtenialDevice Power Battery Calculations SECTION 5 Battery Calculations 5.1 External Device Power The FOPS provides filtered 24 VDC power that may be used for operating Notification Appliance Circuits or other external devices. The power for operating external devices is limited. Use Table 5.1 (standby or nonalarm) and Table 5.2 (alarm) to determine if external loading is within the capabilities of the power supply. Refer to the device manufacturer's data sheets packaged with each device to find the standby and alarm current draws to use in the tables that follow. 5.2 Device Standby Current Draw The following table should include the total standby current draw of all devices on each active output, including End-of-Line relays when used for supervision. Device Type # of Devices Current (amps) Total Current (amps) Main PC Board without AC Fail Report Delay Enabled OR Main PC Board with AC Fail Report Delay Enabled (1 maximum) X (1 maximum) X 0.032 = 0.048 = MPM-4 [ ] X 0.008 = EOL Relays [ ] X = Smoke Detectors [ ] X = Smoke Detectors [ ] X = Annunciators { ] X = Auxiliary Devices [ I X = Auxiliary Devices [ ] X = Auxiliary Devices [ ] X = Sum Column for Standby Load = amps Table 5.1 Load in Standby@24 VDC 5.2.1 Current Calculations When Using the 6.0 amps Maximum Current Available: Five minutes under full load (6.0 amps current draw) requires 3.0 AR (Amp Hour) or a 7.0 AH capacity battery. The remaining 4.0 AR capacity must support the FOPS during its required standby time. Because of this, the standby current draw cannot exceed the figures listed below: For 24 hour standby time, the standby current draw cannot exceed 0.166 amps at 24 VDC (24 hours X 0.166A) = 3.984 AR For 60 hour standby time, the standby current draw cannot exceed 0.066 amps at 24 VDC (60 hours X 0.066A) = 3.96 AR To calculate Standby Current, subtract total standby load calculated above from 0.166 amps for 24 hours standby or 0.066 amps for 60 hours standby. This figure should not be less than zero. If the amount is less than zero, the required standby time will not be achieved Title PN 50079:E 09/30/99 23 Battery Calculations Device Standby Current Draw When Using Less than 6.0 amps Maximum Current, use the following tables to determine the proper battery size When Battery Amp-Hour Requirements are for Greater than 7.0 All, cut FCPS juniper WI to disable onboard battery charger and use an external battery charger Device Type # of Devices Current (amps) Total Current (amps) Main PC Board without AC Fail Report Delay Enabled OR Main PC Board with AC Fail Report Delay Enabled (1 maximum) X (1 maximum) X 0.032 = 0.048 = MPM-4 [ X 0.008 = EOL Relays [ ] X = Smoke Detectors [ ] X = Smoke Detectors [ ] X = Annunciators [ ] X = Auxiliary Devices [ ] X = Auxiliary Devices [ ] X = Auxiliary Devices [ ] X = Notification Appliances [ ] X = Notification Appliances [ ] X = Notification Appliances [ J X = Sum Column for Standby Load = amps Table 5.2 Load in Alarm @24 VDC 5.2.2 Secondary Power Source Calculations Use the Total Standby and Alarm Load Currents calculated in Table 5.1 and Table 5.2 for the following battery calculation. Standby Load Current (amps) [ ] X Required Standby Time in Hours [ I (24 or 60 Hours) = Alarm Load Current (amps) [ I X Required Alarm Time in Hours (i.e. 5 mm. = 0.084 hours)) [ = Add Standby and Alarm Load for Required Ampere Hours = Multiply by the Derating Factor of 1.2 X Total Ampere Hours (AH) Required = Table 5.3 Secondary Power Source Calculations Notes: I. Battery size is limited to 7.0 AH using the internal FCPS battery charger 2. For battery sizes greater than 7.0 AH, cut FCPS jumper JP to disable the internal battery charger and use an external battery charger 24 Title PN 50079:E 09/30/99 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0075:176 Page 1 of I CATEGORY: Power Units LISTEE DESIGN INSTALLATION MARKING APPROVAL: XLF: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 Model FCPS-24F remote power supply/battery charger. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, product designation, electrical rating and UL label. Listed as remote power supply/battery charger for use with separately listed electrically compatible fire alarm control units. 7315-0028:178 *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2008 Listing Expires June 30, 2009 Po )Lt Authorized By: BEN HO, Chief LIrcc.., j'f' Fire Engineering Division 00 COOPER Notification Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories LJ LJ Description Designed for life safety, performance and reliabilityj Cooper. All models may be synchronized using the Wheelock SM DSM Wheelock 's cost effective weatherpoof notification appliances Sync Modules Wheelock Power Supplies or other manufacturers include: panels incorporating the Wheelock Patented Sync Protocol: The Weatherproof Appliances Series horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP Strobes RSSWP horn strobe models are 4-wire appliances; the strobes can be Horn Strobes ASWP synchronized while the audible can be connected to a coded fire Horns AH-24WP, AH12WP alarm system or can be set to produce any of eight selectable Multitone Horn Strobes MTWP tones. Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 Features: All strobe models are UL dual listed - meeting both UL1638 • Approvals include: UL Standards 1971 1638 464 and 1480 and UL1971 requirements. As dual listed appliances, these weatherproof strobe: horn strobes and speaker strobes are California State Fire Marshal (CSFM) and New York City for outdoor applications under UL 1638 as well as under UL 1971,(MEA), Factory Mutual (FM) and Chicago (BFP). See the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this With an extended temperature range of —31°F to 150°F (-40°C document to 66°C), Wheelock weatherproof appliances meet or exceed UL • Compliance with the following requirements: NFPA, UFC, outdoortest requirements for rain, humidity and corrosion resistance ANSI 117. 1, OSHA Part 29 1910.165 ADA while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 • Weatherproof with extended temperature range of —40°F to strobe spacing tables (up to 185 candela for wall mounting and 177 150°F (.40°C to 66C)* candela for ceiling mounting). • Dual Listed strobe models (UL 1638 and UL 1971) To enable weatherproof mounting, Cooper-Wheelock provide: the • Industry's highest strobe candela options industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting • Synchronize using the Wheelock Sync Modules or panels to Wheelock weatherproof backboxes on walls or ceilings. The with built-in Wheelock Patented Sync Protocol optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or • Models with field selectable tone, dBA and candela settings WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA* and • Wall or ceiling mounting options WFPA* kits allow a customer to mount the weatherproof appliances S Surface of semi-flush mounting to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and • IN/OUT wiring termination accepting two #12-18 AWG wires Table on page three of this document for a summarization of these at each terminal mounting option: and the required accessories. *The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to -40°F. The AH-24WP, MT-12124 and the ET-1 010 have been ULC tested and approved to -40°F, but not submitted to UL. The AH-12WP has UUULC approval to -31°F. ®0 <jj> MEA APPROVED E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) * Patent Pending NOTE All CAUTIONS and WARNINGS are identified by the symbol A All warnings are printed in bold capital letters A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING This PRODUCT.. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEEIOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS;.. . . . FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR . OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated incandela ratings table. Wall Mount .. Ceiling Mount Wall or Ceiling Mount i1 /T r . - t 1 iRSSWP MIWP RSSWP MTWP RAT ,vu ou tj roovvr-L'e(oL,-rrc rceu 'f...)O Audible . Order Code RSSWP-2475W-FW White . 3034 RSSWP-2475C-FW White 4446 AH-24WP-R Red 7416 RSSWP24MCWH-FR Red . 5161 . . RSSWP-24MCCH.FR Red 5167 AH-12WP-R Red 7415 RSSWP-24MCWH-FW White . 5165 RSSWP-24MCCH-FWWhite 5187 . . Audible Strobe . Audible Strobe . . .. Red 5023 ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 . ASWP-24MCWH-FR Red 5137 ASWP-2475C-FW White 4502 Speaker ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 ET-1010-R . Red 3135 Multi-tone Strobe ASWP-24MCCH-FW White 5157 ET-1010-W White 3137 MTWP-2475W-FR Red 8420 Multi-tone Strobe MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 ___ MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 0.192 Speaker Strobe MTWP-24MCCH-FW White 5122 ET70WP-2475W-FR Red 9077 Speaker Strobe ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 ET70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 ET70WP-24135W-FR Red 4872 ET70WP-24177C-FW White 4859 ET70WP-24135W-FW White 4875 ET70WP-24115C-FR Red 4550 _______________ ET70WP-24115C-FW White 4732 UL Max. Current AH 24 VDC 12 DC High (99) dBA 0.080 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 U L Reverberant dBA @ 10 Feet atts _ 1/811/21 2 4 8 ET-1 010 77 E 80 83 86 87 92 94 T7OWP 78 81 84 87 90 93 95 Candela Series UL 1971 MTWP UL Max Current UL 1638 UL 1638 _Ratings RSS, ET70WP and ASWP c 77°F @ -40°F (Strobe Only) High Med Low _____ ___ 2475 30°° 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 MCCH 0.460 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 UL Max. Current MTWP/MT MT Audible) 24 VDC 12 VDC BA HI STD HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop . 0.098 0.037. 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X * RSSWP-24MCWH X ° X * RSSWP-24MCCH X * X * Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X * X * ASWP-MCCH X * X * * Multitone Strobe MTWP-2475 X X X X * MTWP-MCWH X ° X * * MTWP-MCCH X * X * * Homs/Audibles AH-24WP X X X - X AH-I2WP X X X - X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X X X * * ET70WP-185 X * X * * ET70WP-177 • ° X ° * ET70WP-115 X * X ° * ET70WP-135 X * X * *pending vvr-r..0 I 141400 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R' Red 4696 WFP-W White 4697 Backboxes IOB-R Red 5046 lOB-W White 5047 WPSBB-R Red 9751 WPSBB-W White 3033 WPBB-R Red 9014 WPBB-W : White 4692 WBB-R Red 2959 IAIDD IAI Ofl Mounting Options:. Backboxes, Plates, Gasket Kits Mount Exposed Conduit Concealed. Conduit RSSWP Strobes . WPSBB WPSBB + WP-KIT . WFP ET70WP Speaker Strobes lOB . lOB + WP-KIT . WF•P, ASWP Horn Strobes WPBB Surface Mount ......Flush WPBB + WP-KIT WFPA AHWP Horns WBB - .WFP ET-1 010 Speakers . . WBB . - WFP MTWP Multitone Horn Strobes lOB 10 + WP -KIT WFP Multitone Horn .1OB () + WP-KIT WFP Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. LMILLJ _____ _______ TO NEXTL] ECEDINGI] +E: REDO APPLIANCED PLIANCED -u BLACKO —DOR EOLREJ FACPD +LJ STROBDO AUDIBLED SERIES RSSWP, ASWP, AHWP, MTWP AND MT-1 2/24 APPLIANCES FROND +u TO NEXTD PRECEDINGD -D _uAPPLIANCEDi APPLIANCE ORG tti OR EOLRD F FACPD I SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWPC Strobe Sync 0 Circui 0 Supply[] 0 AUdibi } PS-12/24-:0 91 Power0 LIIote Circul 0 FACPD NAC Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSMD STROBED +0(2) NACU SYNC CIRCUITD RSS 10- +D N-O :FACP OUTU D .IN2 ROBEU NACU CIRCUITO RETURNU Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be ULlisted for outdoor use Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) The appliances shall be available fcr optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute overthe UL Regulated Voltage Range of 16 to 33 VDC and shall. incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting UL 1638 candela ratings up to 180 cd at 77 *F shall be available The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and AudiblelStrobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464 The horns shall be able to produce a continuous output bra temporal code -3 output that can be synchronized The horns shall have at least 3 sound level settings Horn,Strobe combinations shall be able to be synchronized on a single NAC Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe The strobes shall be able to be synchronized The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed .for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1 010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design Speaker with strobes shall be Wheelock Series They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels With built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S9004 WP 11/09 Cooper Notification is Wheelock* (MCJ SAFEPATH WAVE? j COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. 7125-0785:0131 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *ASwp.2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box: Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and *ASV24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0131 Page 2 of 2 RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd, 1575:15175cd,30:30cd,75:75cd,95:95cd,100:100cd,1 10:1 l0cd MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd MCWH: Selectable 135cd,185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at-40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-I2WP, AH-24WP, *ASwp2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (c Series SM or DSM Description Features The Wheelock Series SM and DSM Sync Modules are utilized Approvals include UL Standard 1971 ULC New York City with the Series AS/AH, Series NS/NS4/NH Series RSS Series (MEA) California State Fire Marshal (CSFM) and Chicago RSSP Series SLM and selected strobe applications with other (BFP) Wheelock combination appliances When used with Series AS Audible Strobes and/or Series Uniquely designed to accept an independent strobe and audible input from the FACP and convert to a single output NS Horn Strobes, the SM and DSM Sync Modules provide that connects to Wheelock's Series AS or Series NS family of independent operation of synchronized temporal pattern (code audible strobes 3) horn and synchronized strobe flash, as well as the ability to silence the horn while maintaining the strobe flash. while using Series SM and DSM Sync Modules can also be used to only a single pair of wires. The sync modules are available in synchronize Wheelock 's Series RSS, RSSP and SLM Sync two versions; the SM-1 2/24 for control of a Class B NAC circuit; Strobes and a dual output version, the DSM-12/24 for control of either a 3 ampere per circuit current handling at 12 or 24 VDC Class A or two (2) Class B NAC circuits. Low operating current draw Compatible with all standard fire alarm control panels Meets the NFPA-72 requirement for Temporal Pattern when used with the Series AS/AH and/or Series NS/NS4/NH 3 year warranty POWERPATHCP I AS/AH, NS, HS4/HS FIRE ALARM POWERPATHMP I NH, RSS, RSSP, CONTROL PANEL OR SM OR DSM _____ E w/STB, ET w/STB, (FACP) OTHER POWER CH w/STB BOOSTERS APPLIANCES SM or DSM Connection Diagram with Power Booster iiEA APPROVED E5946 151-92-E 7300-0765:132 rable I Sync Module (SM) Current Requirements (AMPS) Table2 Sync Module (DSM) Current Requirements (AMPS) UL ULC Rated Average Rated Peak Rated Inrush UL ULC Rated Average Rated Peak Rated .Inrush Voltage Voltagó Current Current CUrrent Voltage Voltage Current Current Current Ini Audible Ini Audible Ini Audible In11In2 Audible lnhlln2 Audible In111n2 Audible 8.0 VDC 10.5 VDC 0.017 0.004 0.055 0.004 0.140 0.016 8.0VDC 10.5 VDC 0.019 0.004 0.055 0.004 0.150 0.016 12.0 VDC 12.0 VDC 0.017 0.004 0.060 0.004 0.160 0.019 12.0 VDC 12.0 VDC. 0.020 0.004 0.064 0.004 0.170 0.019 24.0 VDC 240 VDC 0.028 0.008 0.070 0.008 0.320 0.030 24.0 VDC 24.0 VDC 0.035 0.008 0.080 0.008 0.342 0.030 "33.0 VDC 33.0 VDC 0.038 0.010 0.080 0.010 0.440 0.040 33.0 VDC 33.0 VDC 0.045 0.010 0.090 0.010 0.470 0.040 1.0 VRMS 8.0 VRMS 0.026 0.006 0.085 0.008 0.210 0.016 8.0 VRMS 8.0 VRMS 0.028 0.005 0.107 0.008 0.210 0.016 12.0 VRMS I2.0 VRMS 0.028 0.006 0.090 0.009 0.225 0.019 12.0 VRMS 12.0 VRMS 0.030 0.006 0.103 0.009 0.240 0.019 24O VRMS 24OVRMS 0040 0.010 0.120 0.015 0446 .0.033 24OVRMS24OVRMS 0,048 0010 0.145 0015 0.480 0033 33.0 VRMS3I.0 VRMS 0.055 0.012 0.150 0.022 0.645 0.056 33.0 VRMS 31.0 VRMS 0.062 0.012 0.175 0.022 0.685 0.056 NOTE All CAUTIONS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. A WARNING MAKE SURE THAT THE TOTAL CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO A SM OR DSM DOES NOT EXCEED 3 OA OR EXCEED THE RATING OF THE FIRE ALARM CONTROL PANELS PRIMARY AND SECONDARY POWER SOURCES AND NAC CIRCUITS OVERLOADING THESE SOURCES COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. When calculating the total current, use Tables 1 & 2 to determine the highest value of Rated Average Currenr for the SM or DSM (across the listed volt- age range), then add this value to the total current for any other appliances powered by the same source and include any required safety factors. Refer to Instruction Sheet for addtional information WARNING: MAKE SURE THAT ALL FUSES USED ON NAC CIRCUITS ARE RATED TO HANDLE THE MAXIMUM INRUSH OR PEAK CURRENT FROM ALL APPLIANCES ON THOSE CIRCUITS. FAILURE TO DO THIS MAY RESULT IN LOSS OF POWER TO THE NAC CIRCUIT AND THE FAILURE OF ALL APPLIANCES ON THAT CIRCUIT TO OPERATE, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Table 3: Current Consumption of the SM and DSM Modules Outpurt Circuit Description of SM/DSM Module SM DSM Module Module Ref. Fig. Class "B" with Audible Silence (single circuit) Y 1 Class "B" with No Audible Silence (single circuit) Y 2 Class "B"with Audible Silence (dual circuit) Y 3 Class "B" with No Audible Silence (dual circuit) Y 4 Class "A" with Audible Silence (single circuit) Y 5 Class "A" with No Audible Silence (single circuit) V 6 Note: SM Sync Modules are rated for 3.0 amperes at 12/24 VDC; DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). ACAUTION: Use SM or DSM Sync Modules only on NAC circuits with continuously applied voltage. Do not use SM or DSM Sync Modules on coded or interrupted NAC circuits in which the applied voltage is cycled on and off. ACAUTION: Power Boosters may be used in conjunction with the SM or DSM Sync Modules only in the order shown below. Only one SM or DSM Sync Module shall be allowed on a NAC circuit. Do not connect Power Booster to the NAC circuit after the one SM or DSM Sync Module. Exception: The Wheelock PS-24-BMC Power Booster can be connected either before or after the SM or DSM Sync Module. Refer to Power Booster instruction manual for proper application and installation. S SMULLE UOtLE 4APR &DiI.t TREN ____ MEW 1-1G. 1 SINGLE ULASS b" (NUUI I WI I H FIG. 2 SINGLE CLASS "B" CIRCUIT WITH NO AUDIBLE AUDIBLE SILENCE FEATURE SILENCE FEATURE DUA4 3YP4C MODU4. 40 FIG. 3 DUAL CLASS "B" CIRCUIT WITH AUDIBLE FIG. 4 DUALCLASS"B" CIRCUIT WITH NO AUDIBLE SILENCE FEATURE .SILENCE FEATURE ; M~t FIG. 5 SINGLE CLASS"A" CIRCUIT WITH FIG. 6 SINGLE CLASS "A" CIRCUIT WITHOUAUDIBLE AUDIBLE SILENCE FEATURE SILENCE FEATURE Notes AM Non-Sync Appliances can be installed before or after a SM or DSM. If the Non-Sync appliance requires audible silence, four wire connection is necessary with the strobe circuit connected before the SM or DSM NAC circuit, and the audible leads connected to a silenceable NAC circuit from the FACP. The audible appliance produces a momentary interruption (approximately 25ms) each time the strobes flash. Circuit #2 may be omitted if only 1 circuit is required when using the DSM. Non-SyncAudible Appliances can be installed on the audible NAC. Be aware of the current requirement for the SM or DSM module. See table 3. Soecifications and Orderina Information Input Average Model Order Voltage Current UL Mounting Code VDC c 12 or Max* Options 24 VDC SM-1 2/24-R 6369 12 0.017 0.023 W 24 0.028 0.038 W DSM12/24R*** 6374 12 0.020 0.026 W 24 0.035 10.055 W R = Red * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed volt- age range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. ** Refer to Data sheet # S7000 for Mounting Options. The maximum number of interconnected DSM modules is twenty (20). The total distance from the first to the last DSM shall not exceed 1,000 feet of #18 AWG wire. Use only #18 AWG wire. áWARNING THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 9-14 VOLTS USING FILTERED DC OR UNFILTERED FULL-WAVE RECTIFIED (FWR). DO NOT APPLY 80% AND 110% OF THESE VOLTAGE VALUES FOR SYSTEM OPERATION, THE APPLICATIONOF IMPROPER VOLTAGE MAY RESULTIN DEGRADED OPERATION OR DAMAGE TO THESE PRODUCTS, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA) local state county, province district federal and other applicable building and fire standards guidelines regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). AWARNING: CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" (P83123-SM & P83177-DSM) AND "GENERAL INFORMATION" SHEET ON THESE PRODUCTS. These documents do undergo periodic changes. It is important thatyou have current Information on these products. These materials contain important information that should be read prior to specifying or installing these products including TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NAC CIRCUITS TO HANDLE MAXIMUM INRUSH OR PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE NAC CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. -THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON NAC CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE DO NOT USE STROBE ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH Architects and Enaineers Sncif,eation The sync modules shall be Wheelock Series SM or DSM Sync Modules. Series SM or DSM Sync Modules shall be the master control- lers for Wheelock Series AS/AH, NS/NS4/NH, RSS, RSSP and appliances where a synchronized audible/visual audible or visual only appliance is specified. All modules shall be UL listed under Standard 464. Series SM and DSM modules shall be designed to interface with Series AS Audible Strobe Appliances and NS Horn Strobe Appliances to produce a syn- chronized temporal (Code 3) horn as well as synchronized strobe flash on a two-wire alarm circuit. Other synchronized products are the Wheelock Series RSS, RSSP, SLM visual only appliances and SeriesAH and NH Horn Appliances. SM Sync Module shall incorporate two input NAC circuits for power connection from the Fire Alarm Control Panel; one for the strobe NAC circuit and one for the audible NAC circuit. DSM modules shall provide an additional strobe circuit input/output for control of either two Class "B" NAC circuits or a single Class "A" NAC circuit. Upon activation of the audible silence function at the Fire Alarm Control Panel, the audible signal component of Series AS Audible Strobe and/or the Series NS Horn Stobe may be silenced while maintaining strobe activation. Series SM or DSM module shall be designed and available in two versions; the SM-12124 for control of a single Class B NAC circuit and a dual output version, the DSM-1 2/24 for control of either Class A two (2) Class B NAC circuits. The DSM dual circuit version shall provide the additional capability of "daisy-chaining', that is, the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. Interconnection capability shall be for a maximum of 40 NAC circuits. All modules shall operate on either 12 or 24 VDC. Rated average durrent requirement for the SM 12/24 shall be .017 amperes @ 12 VDC and .028 amperes @ 24 VDC. The DSM 12/24 shall be .020 amperes @ 12 VDC and .035 amperes @ 24 VDC. A single circuit SM Sync Module shall be capable of handing a 3 ampere load at 12 or 24 VDC and the dual circuit DSM Sync Module shall be capable of handling a load of 3 amperes per NAC circuit at 12 or 24 VDC. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of #18 to #12 AWG wire size. The SM and DSM Sync modules shall mount to a 4-11/16' x 2-1/8" deep backbox. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. I'tT1."1 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S3000 SM/DSM 02/08 Cooper Notification is Wheelock* IMEDCJ SAFEPATH WAV COOER Notification CATEGORY 7300 FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE Cooper Wheelock Inc 7246 16th St E Ste 105 Sarasota FL 34243 Contact Tom Conover (941) 487-2336 Email thomas.cohover@cooperindustries.com DESIGN Models SM 12/24 SMX 12/24 DSM 12/24 and DSMX 12/24 Synchronized Control Modules Models SM 12/24 and DSM 12/24 may be followed by R W X or S Refer to listees data sheet for additional detailed product description and operational considerations RATING 8 33 VDC* INSTALLATION In accordance with listee s printed installation instructions applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING Listee s name model number, electrical rating and UL label APPROVAL Listed as signaling appliances accessory, for use with separately listed synchronized strobe lights For indoor use only. *Rev. 05-26-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division J PART NUMBER: FPL1120 DESCRIPTION 2/18 Solid FPLR Cable CONSTRUCTION This cable consists of two bare copper insulated conductors and an overall jacket APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0,010' Insulated Conductor Diameter .0.060". Number of Conductors 2 Nom Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter .0. 170" Approximate Cable Weight (lbsiKft.) 20 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20C 6.43 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 35 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating • -20 C to 60 C Insulation Colors Red and Black Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D E F ZONE 0 12 3456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification issue Date: Nov 19, 2005 .--.--.__ PIR A9 Product Specification Issued 20.05. FIRE ALARM JACKETED UNSHIELDED, RISER RATED to PART NUMBER: FPL1140 to DESCRIPTION: 2/14 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cable for Riser Applications. ConstructIon Parameters Conductor 14AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.015" S Insulated Conductor Diameter 0.094" Number of Conductors 2 Nom Lay Length 5.5". Jacket Material PVC Jacket Thickness 0.025" Nom. Overall Cable Diameter 0.240" Approximate Cable Weight (lbs.IKft.) 40 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20"C 2.52 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 40 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 "C to 60 'C Insulation Colors Black and Red Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D E F ZONE 0 12 34567 89 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 ...................................... _ CABLE -... . - LISTING No. 7161-1505:0100 Page 1 of 1 CATEGORY 7161 CABLES FIRE PROTECTIVE SIGNALING LISTEE JINAN PAC CABLE & WIRE COMPANY248 Avenida Victoria Unit A San Clemente CA 92672 Contact Christoper Derek McMullen (949) 531-8996 Email:.de.rek.i.ncmullenl.@grhail.co.m DESIGN Power Limited Fire Protective Signaling Cable Type FPL FPLP and *FPLR Refer to listee's data sheet for additional detailed product description and operational considerations Insulation:.PVC SRPVC with minimum average thickness of 6 mils minimum at any point at 5 mils PVC compound Apex 910 with minimum average thickness of 6 mils minimum at any point at .5 mils maximum average thickness at 14 mils *PVC compound TeknorApx 96 A025A 115 with min. average thickness 6 mils min. at any point 5 mils Shield. (Optional): Aluminum/polyestertape. Core Wrap (Optional) Polyester tape 2 mils thick max Jacket PVC compound Teknor Apex 4128 PVC Compound Apex 910 and *PVC Compound 90 A033A 10 INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Type FPL, FPLP or *FPLR and UL label. APPROVAL: Listed as a power-limited fire protective signaling cable. *Rev. 11-14-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 201.9 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division