Loading...
HomeMy WebLinkAbout2858 LOKER AVE E; 200; FPC2019-0203; PermitCL7city of Carlsbad Print Date: 12/08/2020 Permit No: FPC2019-0203 Job Address: 2858 LOKER AVE E, # 200, CARLSBAD, CA 92010-6673 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel 4*: 2090832100 Valuation: $2,967,105.45 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track 4*: Lot 4*: Project 4*: Plan 4*: Construction Type: Orig. Plan Check #: Plan Check 4*: Applied: 08/26/2019 Issued: 09/12/2019 Finaled Close Out: 11/22/2019 Inspector: Final Inspection: Project Title: Description: NATIONAL TIRE WHOLESALE -SPRINKLER TI (29 HEADS) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 5 MELROSE PL, #244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 0 0 cs1 MATERIAL DATA SUBMITTAL NATIONAL TIRE WAREHOUSE 2858 LOKER AVENUE EAST - SUITE 200 CARLSBAD, CA 92010 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 Sprinkler Reliable F 1 FR56 Sprinkler 20-25 Sprinkler Tyco ESFR-25 sprinkler 26 Hanger Afcon Fig. 300 Ring Hanger 27 Hanger Afcon Fig 655 All Thread Rod 28-29 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc©gmail.com 0 DynamThread" Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. S S Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <~> @ Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40fDyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, thy deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. WI. (H20 Filled) Pcs/ Wt/Lift (21') WtI1.ift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 11/4' 1.408 1.870 2,54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 l'/z" 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 tqco/Flow Control () JIjecJ 16100 S. Lathrop' Harvey, IL 60426 11350 Norcom Rd. • Philadelphia, PA 19154 TUBE& CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna-Thread Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NPS Nominal 1.0. Wt. WI. (H20 Filled) Pcs/ WULilt (211) Wti1.ift (241) Wtfl.ift (251) In; mm In; mm Lbs/Fl; Kg/rn LbsJFt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105i 1¼' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1h/2 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3,4 4.79 44 959 1097 1145 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured Us L with Exterior galvanized coating. BLT is @ 9 manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: 0 Engineer: Speciflcation Reference: System Type: Locations: Comments: 2 S3-4 'S tqCo Fire & Building I)Pro duc ts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 S S Pipe Fittings NPT Threaded, Ductile Iron General Description The Tycoe Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17.2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the mate pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any and all other warranties. ex- cress or implied, including warranties of merchantability and fitness for a carticular curcose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or detect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. registered trademark of E. I. du Pont de Nemours and Company or its affiliates. TFPI7IO Page 2of 10 TFPI7I0 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 0N25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 2.70 86782 0N65 (68,3) (1,22) I -] FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (1910) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 86204 1,94 1.00 (39,6) (1,49) (49,3) (25,4) TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 TFPI7IO Page 3 of 10 FIGURE 812 900 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C 0 Approx. Weight Part Inches Inches Inches Inches Inches Lbs. DN (mm) (mm) (mm) (mm) Number (kg) 314x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x1/2 1.25 1.38 0.56 0.81 0.44 86210 0N25 x 15 (31,8) (35,1) (142) (20,6) (0,20) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 0N25 x 20 (35.1) (36,6) (17,5) (22,4) (0,24) 1-114x 1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32x15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4x3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-1/4x1 1.56 1.68 0.88 1.00 0.77 86214 0N32 x 25 (39,6) (42,7) (22,4 (254) (0,35) 1-1/2 x 3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40 x 20 (38,1) (44,4) (19,0) (30.2) (0,43) 1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-1/2x1-114 1.81 1.88 1.13 1.19 1.14 86216 0N40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2x2 2.38 2.63 1.25 1.88 3.01 86262 DN65x50 (60.5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 0 TFPI7I0 Page 5ot1O 0 S Nominal Pipe Size Approx. ANSI Inches Weight Part DN Lbs. Number (kg) 1/2 0.18 72779 DN15 (0,08) 3/4 0.26 72778 DN20 (0,11) 44 1 0.4472755 0N25 (0,20) 1-1/4 0.54 72754 DN32 (0,24) 1-1/2 0.71 72753 DN40 (0,32) 2 1.15 72752 0N50 (0,52) 2-1/2 2.29 72758 DN65 (1,04) f-.7 _ Wit FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING 1.63 Figure 814 Figure 818 A B Approx. A B Inches Inches Weight Part Inches Inches (mm) (mm) Lbs. Number (mm) (mm) (kg) 1.13 0.56 0.33 86340 1.38 0.31 (28,7) (14,2) (0115) (35,1) (7,9) 1.31 0.75 0.50 86341 1.63 0.56 (33,3) (19,0) (0,23) (41,4) (14,0) 1.50 0.81 0.85 86230 1.75 0.38 (38,1) (20,6) (0,38) (44,4) (9,7) 1.75 1.06 1.30 86231 2.00 0.56 (44,4) (26,9) (0,59) (50,8) (14,0) 1.94 1.19 86232 2.19 0.75 (49,3) (30,2) (0,74) (55,6) (19,0) 2.25 1.50 2.63 86233 2.63 1.13 (57,1) (38,1) (1,19) (66,8) (28,7) 2.69 1.56 4.55 86234 3.00 0.75 (68,3) (39,6) (2,06) (76,2) (19,0) TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 TFPI7I0 Page 6of 10 S 0 S S Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C D E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN (mm) (mm) (mm) (mm) (mm) (mm) Lbs. Number (kg) 1-1/2x1-1/4x1/2 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 0N40 x 32 x 15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,7) (0,47) 1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 DN40x32x20 (38,1) (36,6) (44,5) (1910) (19,0) (30,1) (0.50) 1-1/2 x 1-1/4 x 1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 86259 DN40x32x25 (41.4) (39,7) (46,0) (22,4) (22,4) (28,7) (0,59) 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40x32x50 (55,6) (54,1) (50,8) (36,6) (36,6) (57,1) (0,88) 1-1/2x1-1/2x1/2 144 1.44 1.69 0.69 0,69 1.13 1.14 86261 DN40x40x15 (36.6) (36,6) (42,9) (17.5) (17,5) (28,7) (0,52) 1-112x1-1/2x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 DN40x40x20 (38.1) (38,1 (44,4) (19,0) 86262) (19,0) (30,1) (0.56) 1-1/2x1-112x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 DN40x40x25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2x1-1/2x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 DN40x40x32 (46,0) (46,0) (47,6) (27.0) (27,0) (30,1) (0,68) _______ 1-1/2x1-1/2x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN40 x 40 x 50 (55,5) 5,5) (50.8) (36,6) (36,6) (31,7) (0.91) 2 xl x 2 2.25 .00 2.25 1.50 1,31 1.50 2.18 86266 DN5O x 25 x 50 (57,2) 0,8) [15 (57,2) (38,1) (33,3) (38,1) (0.99) 2x1-1/4x2 2.25 .13 2.25 1.50 1.44 1.50 2.31 86267 DN50 x 32 x 50 (57.2) 4,1 ) (57,2) (38,1) (36.6) (38.1) (1,05) 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 0N50 x 40 x 15 (38.1) (36,6) (47,8) (19.0) (17.5) (33,3) (0,68) 2x1-1/2x314 1.63 1.50 1.94 0.88 0.75 1.38 1.61 86269 DNSO x 40 x 20 (41,4) (38,1) (49,3) (22.4) 1 (19,0) (35,0) (0,73) 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 86270 DN50 x 40 x 25 (44,5) (41,4) (50.8) (25.4) (22,4) (33.3) (0,75) 2x1-1/2x1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 86272 DN50 x 40 x 40 (52.4) (49.2) (55,5) (33,3) (30,2) (36,6) (0,92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN50x40x50 (51,1) (55.5) (63,5) (38,1) (36,6) (38.1) (1,07) 2x2x1/2 1.50 1.50 1.88 0.75 0,75 1.31 1.50 86222 DN50x50x15 (38,1) (38.1) (47.8) (19,0) (19,0) (33,3) (0,68) 2 x 2 x 3/4 1.63 1.63 1.94 0.88 0,88 1.38 1.67 86223 DN50x50x20 (41,4) (41,4) (49,3) (22,4) (22,4) (35,0) (0,76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 DI'450 x 50 x 25 (44,5) (44,5) (50.8) (25,4) (25.4) (33,3) (0,86) 2x2x1-114 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28.7) (28.7) (36.6) (0.93) 2x2x1-112 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55,6) (31,8) (31.8) (38.1) (0,96) 2x2x2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3,67 86227 DN50 x 50 x 65 (66.8) (66,8) (60.5) (44,5) (47.8) (36.6) (1,66) 2-1/2x2x314 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65x50x20 (44,5) (41,4) (58,7) (15.9) (22.4) (44,5) (1.01) TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 E Page 8 of 10 TFPI7IO n !!IHI1 one FIGURE FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part ON (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 0.88 0.15 72776 1.66 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0,10) (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DM25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 0N32 (33,3) (0.24) (63,5) (26,9) (0,70) (35,1) (0123) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 DM40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) 86296 (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 DNSO (38,1) (0,43) (79,5) (41,4) (1143) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DM65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 TFPI7I0 Page 9ot1O IA 1EA 0 A 1 _ FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 DN15x15 (38,1) (0,09) 1/2 x 1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 314x3/4 1.50 0.22 72981 - - - - - - DN20 x 20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - DN20x20 (50,8) (0,14) 3/4 x 1/2 - - - 1.75 0.69 0.36 86772 DN20 x 15 (43,2) (17,5) (0,17) 1 x 1/2 - - 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25x 15 (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 - - * 1.06 0.18 72762 1.75 0,50 0.53 86229 DN25 x 20 (26,9) (0,08) (43,2) (12,7) (0,24) 1-1/4x1 - - - 1.19 0.31 72763 - - - - DN32 x 25 (30,2) (0,14) 1-1/2 x - - - 1.25 0.53 72757 - - - - 0N40 x 25 (31,7) (0,24) 1-1/2x1-1/4 - 1,25 0.35 72764 - - - - DN40x32 (31,7) (0,10) 2x1 - - - 1.38 0.75 72759 - - - - DN50x25 (35,1) (0,34) 2 x 1-1/4 * - 1.38 0.69 72761 - - - - DN50x32 (35,1) (0,31) 2x1-1/2 - - - 1.38 0.62 72775 - - - - DN50x40 (35,1) (0,28) 8 0 t qC0 /Fire & Building / Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description Listing/Approval Inlomiation The Figure 40-5 Strap isan economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as wellas wlththeapplicab!e standards of the National Fire Protection Association, in addition to the standards ofanyotherauthorities ha ving jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition, The installing contractor or sprinklermanufacturershouldbe contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing/ Approval information. Page 1 of 2 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPOM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythequantity,figure number, type of gasket, Grade "E" EPOM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be Immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. September 2004 Limited Warranty Products manufactured by Tyco Are Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand property installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment bylyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwithTyco Fire Products orfor products and components which have been subject to misuse, improperinstailation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), andlorthestandardsofanyotherAuthorities Having Jurisdiction. Materials found by Tyco Are Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Are Products neither assumes, nor authorizes any person to assumeforit, any otherobllgedoninconnectionwfth the sate of products or parts of products. Tyco Fire Productsshatlnotberesponsibleforsprinklersystern design errorsorinaccumteorincompleteinformation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCOFIREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. (B TFPI72O Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run x Inches inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11140 X /2° 2.00 1.50 3.50 1.20 1/16 0.84 50.8 38.1 88.9 30.5 30.2 0.4 11/4" , 3/ 4 0 2.00 1.50 3.50 1.20 1Iis 0.88 50.8 38.1 88.9 30.5 30.2 0.4 1'/4" X i" 2.31 1.68 3.50 1.20 1/i 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/20 X /2" 2.12 1.62 3.50 1.32 13'i6 0.84 53.8 41.1 88.9 1 33.5 30.2 0.4 11/2"X3/4° 2.12 1.62 3.50 1.32 13A6 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/20 x 11. 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 20 X 1/2' 2.36 1.86 3.74 1.55 1/1G 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2 x 3/40 2.36 1.86 3.74 1.55 1/16 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2'x 10 2.67 2.04 3.74 1.55 13Ae 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2" X 1/2I 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2" X3/4° 2.61 2.11 4.25 1.80 13'16 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2-' X i 2.92 2.29 4.25 1.80 13'16 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) V/4°X 1" 8 11/2"X 1' 6 20 x1' 6 2V2"x 10 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFPI 720 Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. 12 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure IS that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (11-1-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Bulletin 014 Rev. L 41 bile Model Fl FR Series Quick Response Standard Spray :3 C -J r_ Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH 'NSF Certified to NSF/ANSi Standard 61 Annex G EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA 1 425), 0786-CPD-40252 (RA 1 475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR56, Fl FR56LL, Upright Pendent Vertical Sidewall Horizontal Sidewall Recessed Concealed Horizontal Sidewall Pendent XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Conventional * Recessed Pendent/Fl/F2 3/ Recessed Pendent/FP XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 74FG06A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL0) K 5.6 Quick 1/2" NPT See See F1FR42 **F1FR42LL0) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" Fl FRXLH Ratings" Table. F1FR28 K2.8 (1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *pmntle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass ""Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDAAlloy5lO CDA Alloy 693 Tape 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3, 4, 6 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 RA14134 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA141 1 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475, Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 1 5.6 I 80 2.25" (57mm) 1,5 RA1415 7/16(11mm) 1/2" NPT (R1/2) ] 4.2 60 2.25" (57mm) 1,5 RA1410 " cULus listed corrosion resistant (Polyester coated) sprinkler. S *DuPont Registered Trademark 3. Sprinkler Type Deflector to Ceiling Distance (Mm. -Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4(102mm) - 12" (305mm) S Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) j 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1411 " Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler41 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16(10mm) 1 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1410 Refer to escutcheon data table for approvals & dimensions 'RENT 0., to,.,- X/NTREOUCET TERN CROSS MATE TROT / FACE OP RETWE r \ / ro PACE OF COSINE DIMENSION AT MAXIMUM RECESS T25.4,,,,,,1 AT MINIMUM RECESS - J/879.5nnnj RECEZ - VA — 1/11= V2727m,nJ ATM US - OORNT) ILli III Itli ,,,. J Ar MAXIMUM RECESS ?/8T22.2mnJ Ar AREETMUM RECESS - T-T/8Y2&E,,,m V I AT MITE/MUM RECESS - T-O/BTAI.JNN, 8 _ Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Fl or F2 IX 112- REDUCER 2 $/ 004.[6&7-1 H" IN 007UNG 2 5/l8 00. (5&7REREJ CUP CEIUNG PA CE OF PORNO TO FACE OF CETUNO DEMOWREON i E - t-t/2T38or,mJ A r RECESS JAA T MINIMUM MATMUM RECESS Tl2j,,,,,,J AT MAXIMUM RUCE - 9/16V4.JFRR,J AT MINIMUM REEN - IT25.4R,R,J ADI/USIMOET 3 t/4 (82.&,onJ 1 Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2,3 RA 1485(2)(3) 15mm ½" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (leflonUT)* Plated - cULus listed corrosion Resistant Vertical Sidewall *DuPont Registered Trademark 4. Horizontal Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler _________________ Height and Type of Approval Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN)Hazard ½" (15mm) ½" NPT (191/2) 5.6 80 1 2.63" (67mm) 1,2 1 " cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant S 1 (1) I 15/16" 0/A 2 27/ 4"-12" 4 [101.6mm-304.8mm] 32 0/A CEILING TO [72 2mm] DEFLECTOR TURN COLLAR UNTIL L. TIGHT AGAINST SPRINKLER I WRENCH ROSS Fl ESCUTCHEON I 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2 "(12.7mm] ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4' - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1"[25.4mm] AT MINIMUM RECESS = .3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] 2 1/4" HOLE OIA. [5 7.2mm] 1" X 1/2" REDUCER Fl ESCUTCHEON AT MAXIMUM RECESS 1-3/8734.9mm] AT MINIMUM RECESS = 2-1/16752.4mm] / F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8[41.3mm] -1/8' AT MINIMUM RECESS = 2-1/16(52.4mm] (3.2mm] S Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model AOl Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover ½" (15mm) 5.6 80 ½" NPT F1 FR 1350F/570c 135°F/570c 100°F/380c Orange 1 RA1414 ½" (15mm) 5.6 1 80 1 ½" NPT I F1 FR 155°F/680c 1350F/570c 1 100°F/380c Red 1, 4)1), 6 RA1414 ½" (15mm) 5.6 80 ½" NPT F1 FR 1750F/790c 1650F/740c 100°F/380c Yellow 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1 FR 200°F1930c 1650F/74°c 150°F/65°c Green 1 RA1414 (1) For VdS only = 155"F/68"c Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size I Model I Temp. Rating Max. Ambient Bulb Color Approvals Sprinkler Identification US Metric I Sprinkler Cover Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/930c 165°F/740c 150°F/65°c Green 1,5 RA1414 "DuPont Registered Trademark 5. S I" x 1/2" REDUCING TEE OR ELBOW —E --------' 2 5/1 6DIA — HOLE IN CEILING CUP I FACE OF FITTING CEILING . .IJ .. _ LE.T0_FACE OF CEILING COVER ADJUSTMENT 15/16" COVER PLATE - ASSEMBLY 3 5/16 0/A. -.- SPRINKLER CONCEALED. 1/2" ADJUSTMENT D17FWIA Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown, The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LLICCP Concealed Sprinkler use the ½" orifice, ½" NPT (R1/2), Model F1FR56 & Fl FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark x 1/2" REDUCING TEE OR ELBOW 2 5/8" 0/A. 2 5/16" DIA - HOLE IN CEILING CUP I 1 7/2 MAX. I FACE OF FITTING TO FACE OF CEILING DIMENSION MA .ING 5/16" MAX. _J 3/4" COVER AO,JUSTMENT COVER P/ATE— ASSEMBLY L J 16"DIA SPRINKLER CONCEALED. 5/16" ADJUSTMENT orz Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model AOl Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RO1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASOO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. S Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color °C OF Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) 141 286 225°F (107°C) Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus perms use with Fl F2 or F escutcheons for light hazard" only, while FM limits use for same hazard with F2 escutcheon only Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, El FR42LL, Fl FRXLH & El FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate0 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated )4))5))6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate0 Electroless Nickel PTFE(Teflon®)*(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass 3 Bright Brass Black Plating Black Plated Black Plated I Black Paint Black Paint)2))6) Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (II Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark 7. Worldwide I tqcae Contacts www.tyco-fire.com Model ESFR-25 252 K-factor Pendent Sprinkler Early Suppression, Fast Response C General Description TYCO Model ESFR-25 Pendent Sprin- klers are Early Suppression, Fast Response (ESFR) sprinklers having a nominal K-factor of 25.2 (Ref. Figure 1). They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Sprinklers are pri- marily used for ceiling-only sprinkler protection of, but not limited to, the fol- lowing storage applications: most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards some storage arrangements of rub- ber tires, roll paper, flammable liq- uids, aerosols, and automotive components For more specific criteria, refer to Table B as well as the applicable design standard. The Model ESFR-25 Pendent Sprin- klers provide the system designer with hydraulic and sprinkler place- ment options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprin- kler has been designed to operate at IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 substantially lower-end head pres- sures, as compared to ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as possi- bly reducing or eliminating the need for a system fire pump. Also, Model ESFR-25 Sprinklers permit use of a maximum deflector-to-ceiling distance of 18 in. (460 mm) versus 14 in. (356 mm). Additionally, a storage arrangement of 40 ft (12,2 m) with a ceiling height of 45 ft (13,7 m) does not require in-rack sprinklers as do other ESFR Sprinklers having nominal K-fac- tors of 14.0 and 16.8. The Model ESFR-25 Sprinklers are listed by Underwriters Laboratories (UL) for specific applications with a maximum storage height of 43 ft (13,1 m) with a maximum ceiling height of 48 ft (14,6 m) without the require- ment for in-rack sprinklers. Refer to the Specific Application Listing (UL) for the design criteria. Applications for the TYCO ESFR Sprin- klers are expanding beyond currently recognized installation standards. For information on research fire tests, such as with flammable liquids and aerosols, that may be acceptable to an author- ity having jurisdiction, contact Techni- cal Services. NOTICE The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities having jurisdiction, such as FM Global. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard, or other applicable standard, must be referenced to ensure applicability and AUGUST 2018 to obtain complete installation guide- lines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) Refer to Table A for sprinkler identifica- tion number. Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved NYC Approved under MEA 356-01-F LPCB Certified (Cert. Nos. 094b and 0071) CE Certified (Certificate of Conformity 1725-CPR-F0010) Finish Natural Brass Physical Characteristics Frame .............................Brass Deflector ..........................Bronze Compression Screw ..........Stainless Steel Hook ............................MONEL Strut.............................MONEL Link Assembly................Solder, Nickel Button .............................Brass Sealing Assembly.. Beryllium Nickel w/TEFLON Ejection Spring ..................INCONEL Additional Technical Data Refer to Table A for additional techni- cal data. TFP3I2 Item Description Sprinkler Identification Number (SIN) TY9226 K-factor, gpm/ps1½ (lpm/bar'/2) 25.2 gpm/psi½ (362,9 1pm/bar½) Temperature Rating T (CC) Thread Size 1 in. NPT or ISO 7-A 1 Sprinkler Orientation Pendent Maximum Working Pressure, psi (bar) 175 psi (12,1 bar) TABLE A MODEL ESFR-25 PENDENT SPRINKLER TECHNICAL DATA In addition to this technical data sheet, • TFP3I9 the following data sheets describe Model ESFR-14 (TY6236) other TYCO ESFR Sprinklers: K=14.0 Pendent Sprinkler TFP32O Model ESFR-17 (TY7229) K=16.8 Pendent Sprinkler Roof Construction Unobstructed or obstructed construc- tion, such as smooth ceiling, bar joists, beam and girder. Where the depths of the solid structural members, as in beams and stem, exceed 12 in. (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 in. rise for 12 in. run (16.7%) Maximum Coverage Area 100 ft2 (9,3 m2) TFP313 Model ESFR-22 (TY8226) K=22.4 Pendnet Sprinkler TFP315 Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler TFP316 Model ESFR-17 (TY7126) K=16.8 Upright Sprinkler TFP317 Model ESFR-17 (TY7223) K=16.8 Pendent Sprinkler TFP318 Model ESFR-1 (TY6226) K=14.0 Pendent Sprinkler S TFP3I2 Page 2 of 6 7 ___ A 1 NPT Components: 8 / 1-13/16 1 - Frame 9/16 (46,0 mm) 2 - Deflector / / (14,3 mm) 3 - Compression 9 \ NOMINAL Screw MAKE-IN 4-Hook 6 5 - Strut 3-13/16' 6 - Link Assembly (96,8 mm) THERMAL 7 - Button SENSING 8 - Sealing ELEMENT Assembly 4 9 - Ejection Spring - WRENCH / :A FLATS 3 , 2 TEMPERATURE RATING - 2 (50,8 mm) -1 FIGURE 1 MODEL ESFR-25 PENDENT SPRINKLER, 25.2K EARLY SUPPRESSION, FAST RESPONSE Operation . The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. Design Criteria The following general guidelines pro- vided for the TYCO Model ESFR-25 Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ. Consequently, the appropri- ate standard must be used for a given installation. General guidelines are not intended to provide complete installation criteria. In all cases, the appropriate NFPA or FM Global installation standard must be S referenced to ensure applicability and to obtain complete installation guide- lines. Refer to Table B for additional information. TFP3I2 Page 3 of 6 Storage Type NFPA FM Global Sprinkler Type ESFR Storage Response Type QR OR System Type Wet Wet Temperature Rating °F (°C) 165°F (74°C) 212°F (100-C) 165°F (74°C) 212°F (100°C) Open Frame (i.e., no solid shelves), Single, Double, Multiple- Refer to FM Global Row, or Portable Rack Storage of Class l-IV and Group A or Refer to NFPA 13 2 -0 and 8-9 B_Plastics Solid Pile or Palletized Storage of Class l-IV and Group A or Refer to NFPA 13 Refer to FM Global B Plastics 2-0 and 8-9 Idle Pallet Storage Refer to NFPA 13 Refer to FM Global 2-0, 8-9, and 8-24 Rubber Tire Storage Refer to NFPA 13 Refer to FM Global 2-0 and 8-3 Roll Paper Storage (Refer to the Standard) Refer to NFPA 13 Refer to FM Global 8-21 Flammable/Ignitable Liquid Storage (Refer to the Standard) Refer to NFPA 30 Refer to FM Global 7-29 Aerosol Storage (Refer to the Standard) Refer to NFPA 30B Refer to FM Global 7-31 Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only; refer to the Standard) N/A - Not Applicable TABLE B MODEL ESFR-25 PENDENT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW In some cases, the installation stan- dards permit a greater coverage area. Minimum Coverage Area 64 ft2 (5,8 m2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 ft (3,7 m) for building heights up to 30ft(9,1 m) 10 ft (3,1 m) for building heights greater than 30 ft (9,1 m). In some cases, installation standards permit a greater spacing. Minimum Spacing 8ft(2,4m) Minimum Clearance to Commodity 36 in. (914 mm) NFPA Deflector-to-Ceiling Distance S 6 in. to 18 in. (152 mm to 457 mm) FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Specific Application Listing (UL) TYCO Model ESFR-25 Pendent Sprin- klers are listed by Underwriters Labo- ratories (UL) for Specific Applications with a ceiling height greater than 45 ft (13,7 m) up to and including 48 ft (14,6 m), and a storage arrangement up to and including 43 ft (13,1 m). Refer to Table C for guidelines for the TYCO Model ESFR-25 Pendent Sprin- kler Specific Applications Listing (UL) Design Criteria. Refer to Table C for additional information. S S TFP3I2 Page 4 of 6 Description Specification, UL Sprinkler Type ESFR Temperature Rating T (CC) 165F (74CC) 212F (100CC) Response Type QR Sprinkler Position Pendent, frame arms aligned with pipe, deflectors parallel with ceiling or roof System Type Wet Maximum Area of Coverage 100 ft2 (9,3 m2) Minimum Area of Coverage 64 ft2 (5,8 m2) Maximum Slope Ceiling 2 in. rise for 12 in. run (16.7%) Maximum Spacing 10 ft (3,1 m) Minimum Spacing 8 ft (2,4 m) Deflector Distance from Walls Minimum of 4 in. (100 mm) from walls but no more than 1/2 the allowable distance permitted between sprinklers Deflector to Top of Storage Minimum of 36 in. (914 mm) Deflector to Ceiling Distance 6 in. to 14 in. (152 mm to 356 mm) Maximum Ceiling Height 48 ft (14,6 m) Maximum Storage Height 43 ft (13,1 m) Storage Arrangement Palletized, solid piled, open frame; single row or double row Commodity Class I - IV, Cartoned unexpanded plastic Sprinkler System Design NFPA 13 for ESFR Sprinklers based upon 45 psi (3,1 bar) design pressure 169 gpm (640 1pm) with 12 sprinkler remote area Obstruction Criteria Reference NFPA 13, Chapter 8 Minimum Aisle Width 5 ft (1,5 m) Hose Stream allowance and Water Supply Duration 250 gpm for 60 minutes (950 1pm for 60 minutes) TABLE C MODEL ESFR-25 PENDENT SPRINKLER SPECIFIC APPLICATION LISTING (UL) COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TFP3I2 Page 5 of 6 S S °FIUING SIDE TOWARDS SPRINKLER FITTING WRENCH R SSt ECESS FIGURE 2 W-TYPE I SPRINKLER WRENCH Installation TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Damage to the fusible Link Assem- bly during installation can be avoided by handling the sprinkler by the frame arms only and by using the appropri- ate sprinkler wrench. Do not apply pressure to the fusible Link Assembly. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 1 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lb-ft (26,8 to 40,2 N.m). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Note: Install the Model ESFR-25 Pendent Sprinkler in the pendent posi- tion (Ref. Figure 2). Step 1. With pipe thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pres- sure to the Link Assembly, and handle the Model ESFR-25 Pendent Sprinkler only by the Frame arms. Step 2. Wrench-tighten the Model ESFR-25 Pendent Sprinkler using only the W-Type 1 Sprinkler Wrench (Ref. Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats (Ref. Figure 1). Step 3. After installation, inspect the Link Assembly of each Model ESFR-25 Pendent Sprinkler for damage. In par- ticular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assem- bly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. Care and Maintenance TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.21K Pendent Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to Installation section for additional information. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation, such as NFPA 25, in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Model ESFR-25 Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226), (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) ..................58-441-1-165 212°F (100°C) .................58-441-1-214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-25, Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226) with ISO 7-1 thread connection, (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) .................. 58-442-1 -165 212°F (100°C) ................. 58-442-1 -214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025 TFP3I2 Page 6 of 6 S S 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications and other information shown wore current as of document revision date and are subject to change without notice. Johnson n~12~!A FIRE PROTECTION ASSOCIATION and NFPA are registered tradernaft of National Fire Prolection Association; - 300 RING HANGER zS A)US 1 thru 4 Inch pipe 1/2 and 3/4 inch pipe 5 thru 8 inch pipe n SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H- 171(Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru4 inch: * Offset edge for EASY pipe insertion. I thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru3 inch: * UL listed to accept AFCON#3 10 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE7 ROD 1/2 3/8 400 10 3/4 318 400 20 10 1 3/8 400 s 10 11/4 3/8 400 32 10 11/2 3/8 400 40 10 2 3/8 400 50 10 21/2 3/8 600 65 10 3/8 600 80 10 31/2 3/8 600 10 3/8 1000 100 10 5 112 1250 125 12 6 1250 1 150 12 8 1250 1 200 1 12 * Order Part g300m Note: 1/2 Ring Hanger not <FM> approved S 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F S SIZE - 3/8 thru 7/8 inch rod in 1 inch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. n 2/00 E7 will]D Use #14 Nut - 1/4" Rodr&wnti i mmm Driver (Item #100) Item# Model ShkLgth ShkDia BoxQty 1 Weight iO0) Case Qty GST.750 (per 20 3/4 1/4 100 4.75 1000 21 CST 100 1 1/4 100 5.00 1000 22 GST200 2 1/4 100 6.50 1000 23 IGST300 1 3 1/4 100 7.50 1000 24 IGST600 1 6 1 1/4 1 50 9.00 500 S WOOD - Sammys i #14 (Item #100-black) Sammys 1/4,3/8" rod S(lIl] I1 1T1 (Veilical Use #14 Nut Driver (Item #100) Approvals Item # Model Shk Lgth Shk Dia FMTest Loa lb. ULTest Load lb. UL/FMActual Pipe Size Pullout Box Qty 10 GST.75 3/4 1/4 564#-6Ply 100 NFPA 11 GST10 1 1/4 2104 - 7/16 OSB 670# - 3/4" Ply 100 jUL.FM.NFPA 12 CST 20 2 1/4 9404 8504 3/4-2 1/2 17604 -Fir 100 UL•NFPA * 27 CST 25-380 2 1/2 3/8 15004 4 21134 -Fir 50 UL•FM•NFPA 13 CST 30 3 1/4 14754 1500# 3/4-4 20604 -Fir 100 NFPA 403 CST 40 4 1/4 21804-Fir 50 NFPA 14 IGST60 1 6 1 1/4 1 2230# -Fir 1 50 #I4SW (Item #101-red) Sidewinders & Sammys ll2"rod WOOD - raii Rod r&wnti Mount) Use #14SW Nut Driver (Item #101) Item# Model ShkLgth ShkDia ActualPullout BoxQty Weight Case (per 100) Qty 8 CST 2 2 1/4 17604- Fir 50 7.00 500 * 06 CST 2.5-380 21/2 3/8 21134-Fir 50 10.00 500 15 GST 3 3 1/4 22754- Fir 1 50 10.50 500 16 JGST4 4 1/4 1 21804-Fir 50 1 10.60 500 17 JGST6 6 1/4 1 22304- Fir 1 50 1 10.95 500 Not less than 2" nominal width (11/2") TJI Joist ITruss Consult truss manufacturer for recommended installation point fj,; o 6 0 j I q Wood Joist *pre..drilling may be required for items #27 and #06. Tools available on page 9. S Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance For vertical use. Install in center oflowerface. Page 4 Note: Screws must be installed with appropriate nut driver to comply with wa rranty WOOD Rod n : m1ri llfl LI flTT11Th Use #14SW Nut Driver (Item #101) I Item# I Model 'Shk Lgthl Shk Dia I Actual I I Shear/Pullout Box Qty Weight (per 100) I Case Qty I 4016 ISWG1OO 1 1/4 I 100 7.50 I 1000 I 300 15WC200 2 1/4 17254 -Fir 100 1 8.00 1000 WOOD - 3/8" Use #14SW Rodiri I flu VAU nfl LI ITITtT1 Nut Drier (Item #101) Approvals Item# Model Shk Lgth Shk Dia UL Test Load lb. UIJFM Pipe Size ActualBox Shear/Pullout Qty Weight 11 (per 100) 18 SWIG 10 1 1/4 100 6.00 UL•NFPA 19 SWIG 20 2 1/4 12504 3 1725#-Fir 100 7.00 UL•NFPA I * 26 ISWG2S-380 21/2 3/8 1500# 4 2249# -Fir 50 10.25 - 25 ISWG30 1 3 1 1/4 1 1 1 1 50 1 8.50 S #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod WOOD —Sidewinders Not less than 2" nominal width (11/2") up to 3 1/2" pipe; not less than 3" nominal width 4" & 5" pipe FloorJoist r TJI Joist I Truss Consult truss manufacturer for recommended installation point. *pre..drilling may be required for i/en, /126. Tools available on page 9. [1 lb Minimum 21/2" from bottom for branch lines. Minimum 3" from bottom for mainlines. Exception: I This requirement shall not apply to 2" or thicker nailing strips resting SHEETROCK -Toggle on top of steel beams. 1II M I (lI rii IT (VerticalMount) 'Use #14 Nut Driver (Item #100) Item# Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight Case Qty (per 100) 71 SST 300 3 1/4 4504 Lath & Plaster 50 12.00 500 4044 2 Layers 5/8 Rock #14 (Item #100-black) Sammys 1/4", 3/6" rod 1I I I L(lI 7k4II I1&!flTIT1 LI rmmi lUse #14 Nut Driver (Item #100) Item# I Model Shk Lgth Shk Dia Actual Pullout Pkg Qty Weight Case Qty (per 100) 70 SST 30 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock Note: Screws must be installed with appropriate nut drive, to comply with warranty A Prestressed Concrete C2 S Page 5